1. or dirt the acid cleaner is used to remove mineral scaling Cleaning with just the alkaline cleaner will usually restore the membrane s performance However if low out put or higher than normal pressure continues the acid cleaner should also be used The procedure is the same for both cleaners Use the alkaline cleaner first following the procedure below If the acid cleaner is also required flush the system and repeat the procedure with it Membrane Cleaning Housing Reject brine line is bypassed Freshwater output line is bypassed Discard discharge water for 30 sec then insert hose into Membrane cleaning solution pail Cleaning solion as shown in large pail Figure 1 2 7 Cleaning Procedure Mix four spoonfuls 40 g of the cleaning agent with one gallon approximate 4 liters of clean freshwater in a clean pail The water should be warm but not hot maximum of 122 F 50 C Mix until the cleaner is completely dissolved Grasp the membrane housing with both hands and turn counterclockwise until it can be removed In its place install the special membrane cleaning housing provided with the kit Screw the housing all the way on by hand but don t overtighten Place the suction strainer into the pail of warm water Pump the handle Discard the water coming from the discharge hose on the end of the clean ing housing for about 30 seconds then place the return hose into the cleaning soluti
2. F KATADYN MAKING WATER DRINKING WATER Survivor 35 Model 8013433 English Thank you for purchasing the Katadyn Survivor 35 desalinator It was designed and built to rigorous specifications by Katadyn Products Inc to provide fresh water in emergency situ ations Please before operating the Survivor take the short time needed to read this Manual This small investment of time will help assure many years of trouble free operation Be sure to fill in the enclosed warranty card and return it to us as soon as possible This is required to fulfill the terms of your warranty Important Precautions e Avoid sucking in oil gasoline or other petroleum based products they will quickly destroy the membrane e Avoid drawing water from a confined source As the salt concentration increases the unit will become harder to pump e Do not adjust the relief valve This valve is preset in the factory Adjusting this valve can dam age the pump and void your warranty e t is normal to detect a slight taste in the fresh water However do not drink water with a strong salt flavor e The strainer may eventually clog and need rinsing If the unit is hard to pump either the strain er is clogged or the water is unusually cold or salty e During prolonged emergency use pump the unit for at least 10 minutes each day to keep sea water from stagnating inside the unit e f the unit will not be used again for several days remove any
3. N 55442 USA 8304 Wallisellen Switzerland Phone 800 755 6701 Phone 41 1 839 21 11 Fax 800 548 0406 Fax 41 1 830 79 42 www katadyn com www katadyn ch marine katadyn com info katadyn ch
4. accessible seawater from it To do so remove the intake strainer and hose from the feed water Turn the unit upside down and pump the handle up and down normally until water stops coming out e After the unit has been used flush the membrane with biocide before storing it again This will prevent the growth of bacteria inside the unit Refer to Storage below e f the feedwater has an high bacteria content use biocide daily e Store the biocide in a dry ventilated area e IMPORTANT For your safety we require that an inspection be completed once a year Our regional service centers are trained to perform all necessary quality checks or you can return the unit to Katadyn for inspection IMPORTANT The Survivor 35 is designed for use in emergency conditions After it has been used once under such conditions consult your dealer to deter mine if any service is required Product Specifications The Survivor 35 is a simple hand operated watermaker able to produce over 30 gallons 105 liters of potable water per day from seawater A semipermeable membrane inside the unit acts as a molecular filter When seawater is pressur ized to 800 psi 55 bar by pumping the handle and forced against the membrane only the water molecules can pass through salt molecules are unable to pass and flow out of the system Technology Salt rejection Permeate Flow Weight Dimensions Guarantee Material Reverse Osmosis 98 4 on a
5. ean water wipe dry with a lint free cloth Lubricate the seals on the new element with a small amount of silicone lubricant Insert the element into the pump front then push the reject tube assembly all he way into the element Slide the housing over the element Screw it all the way into the pump collar by hand but do not overtighten Be sure there is no gap between the pump collar and the thread stop on the membrane housing NOOK WD Capscrews 4 pcs 8013018 Hose and strainer assembled Pump Back Pump Front Pump manifold 8012953 Membrane 8012793 Membrane Housing Key Components Figure 1 3 8 Handle 8012994 9 Lanyard not shown Kits not illustrated 1 Biocide 100 g bottle 8013327 2 Membrane Cleaning Kit 8013369 3 Repair Seal Kit 8013053 Storage 7 days or longer The Survivor 35 is shipped from the factory with a biocide solution inside to prevent the growth of bacteria After the unit has been operated and before it is stored again it should be flushed with biocide as outlined below IMPORTANT Never let the membrane dry out Be sure to follow these storage instructions 1 Turn the unit upside down with the intake strainer out of the water 2 Fill a suitable container with about a quart approximate 1 liter of clean water Freshwater is preferable but clean seawater can be used if freshwater is not available 3 Mix one spoonful 10 grams of the b
6. iocide with water until dissolved 4 Place the intake strainer into the biocide solution and pump until water starts flowing out of the reject hose indicating that the membrane housing is filled Stop pumping immediately after water begins to flow from the reject hose 5 If seawater was used to mix the biocide solution repeat the above procedure with freshwater as soon as it is available 6 Rinse any biocide solution off the outside of the unit Allow the unit to dry completely before sto ring IMPORTANT For your safety we require that the above procedure be completed once a year storage temperature lt 25 C 77 F Please be aware to use only biocides supplied by Katadyn or your product Other products like chlorine based products will damage your membrane Limited Warranty Your Survivor 35 is warranted for one 1 year from the date of purchase against defects in mate rials and workmanship Should your Katadyn Survivor prove defective within one year from the date of purchase return it to the Katadyn retailer from whom it was purchased If you do not receive a satisfactory resolution contact Katadyn Consumer Relations at 1 800 755 6701 for serv ice assistance Please retain your purchase receipt as proof of date purchased This warranty gives you specific legal rights and you may have other legal rights that vary from state to state Katadyn North America Katadyn Products Inc 9850 51 st Avenue North Birkenweg 4 Minneapolis M
7. o inhibit biological growth dump the freshwater output for at least 60 strokes to clear the biocide solution from the system Continue pumping until you get the desired amount of water To get more water if you stop pumping temporarily repeat the above procedure The Survivor 35 is designed to operate under the following seawater conditions e Water Temperature 2 to 45 C 36 to 113 F e Salinity 35 000 ppm TDS average Handle Grip Collapsible Freshwater _ ot Container A lt Kee c S C e i Indicating rod Submerged A Intake Strainer if d Figure 1 1 Membrane Cleaning The membrane does not have to be cleaned regularly However even in normal operation it can eventually become dirty or fouled with biological growth and particles which are small enough to pass through the strainer This build up on the surface of the membrane can cause the freshwater flow rate to be low or the operating pressure to be high The most likely symptom will be discharge of seawater from the relief valve on the pump body because of higher than normal operating pressure Under the above circumstances the membrane should be cleaned as described below Use Katadyn s Membrane Cleaning Kit article number 8013369 which consists of a special mem brane cleaning housing and cleaning agents Two types of cleaner are provided with the kit alkaline and acid The alkaline cleaner is used to remove biological fouling oil
8. on con tainer Continue pumping the unit while recirculating for about 15 minutes Stop pumping and allow the membrane to soak for at least an hour For severe fouling an extended soak period of 10 to 15 hours may be desirable After soaking pump the handle again Dump the first few pulses of solution that come immedi ately from the discharge hose When the stream becomes cleaner place the hose back into the pail of cleaning solution and recirculate for another 30 to 60 minutes After cleaning flush by pumping warm freshwater through the system insert the alternate intake hose into a pail of fresh water and run the discharge water from the cleaning housing to a drain If fresh water is not available you may use seawater if it is above 68 F 20 C Remove the cleaning housing and reinstall the normal membrane housing If the unit won t be used for at least 7 days after cleaning follow the inhibiting instructions under Storage Replacing the membrane element If the membrane element is damaged or can not be cleaned anymore please replace the element using the Katadyn Membrane Replacement Kit article number 8012793 and follow the instruc tions below IP 2 3 A 5 6 Grasp the membrane housing with both hands and turn counterclockwise until it can be removed Remove the membrane element with a pulling and twisting motion Clean the membrane housing with a warm mild detergent rinse with cl
9. verage 96 8 minimum The desalination degree effect depends on different influence factors such as pressure throughput and the quality of water 4 5 l h 15 1 2 U S gal hr 3 2 kg 7 Ibs 14 x 56 x 9 cm 5 5 x 22 x 3 5 1 year Pump Stainless Steel plastic Membrane approved by the US FDA Food and Drug Administration 5 Operating Instructions Uncoil intake discharge hoses Drop the hoses and attached strainer into the seawater Be sure strainer is fully submerged Place desalinator across your lap Place one hand on handle grip and the other on the mem brane housing as shown Figure 1 1 Pump handle up and down as far as it will go in each direction at a comfortable rate of speed about 2 seconds per up down stroke After you pump for 1 2 minutes the pressure indicat ing rod will extend itself revealing an orange band Continue pumping so the orange band remains visible If water sprays from the indicator pump slower If orange band is not visible pump faster Once water drips from the freshwater hose pump at least 60 strokes two minutes while dump ing the water overboard This will clear the system of biocide solution and salt that passes through the membrane when not in use Then insert the freshwater hose into a storage container or directly into your mouth IMPORTANT At initial start up of a new unit or of an unit that has been inhibited filled with biocide storage solution t
Download Pdf Manuals
Related Search
Related Contents
XY Laser UltraCluster RGB ORH2222-20 - Département d`organisation et ressources humaines Casio 5027 MO0710-EA User's Manual 取扱説明書 Andis Company BTF2 User's Manual Kenmore 721.63102 Microwave Oven User Manual Hama Internet TV Box II GlobalSat GH-561 User's Manual Manuel d`instructions FOULOIR MOBILE OMEGA - Amos Copyright © All rights reserved.