RVE-2 INSTRUCTION MANUAL

image

Contents

1. 21 6 5 CORREO T E MAINTENANCE bacano ja a 22 6 5 1 Problems Causes Solutions eee eee 22 6 6 SPARE PARTS AND RECOMMENDED TOOLS 11 0 een aa asama 24 6 7 AUTO DIAGNOSTIC DISPLAYCODE erene Ereren reenn 25 6 8 mere Mc 26 Fa TECHNICAL DATA cree ee eee etre tee a ni S 32 B TECHNICAL SERVICE LLL l i i i l ill a dn 32 Manual RVE 2 amp M98238801 03 12B 4 32 9 CIRCUTOR RVEZ 1 OVERVIEW This user manual provides basic information about the electric vehicle charging unit the RVE 2 and his different versions MODE 1 MODE 2 according to EN 61851 1 Important instructions will be shown inside a box In some cases these will include special symbols Their meaning is explained next IMPORTANT INSTRUCTION WARNING DANGER ELECTRICAL RISK Manual RVE 2 amp M98238801 03 12B 57 32 m CIRCUTOR RVE2 2 SYSTEM DESCRIPTION The RVE 2 charge units provide to electric vehicles a plug base up to 16A 240Va c in MODE1 and up to 32A 400Va c in MODES according to EN 61851 1 e RVE 2 Mode 1 o RVE 2 Outdoor recharge posts single phase with two outlets 230Va c 16A 3 6kW o RVE 2 COM Outdoor recharge posts single phase with two outlets 230Va c 16A 3 6kW with RS485 communications o RVE 2 IP Outdoor recharge posts sing
2. m CIRCUTOR RVE 2 Single phase charging mode 1 INSTRUCTION MANUAL M98238801 03 12B v2 0 Edition Mar 2012 Ce 9 CIRCUTOR RVEZ CE ATENCION ATTENTION Manual RVE 2 amp M98238801 03 12B 2 32 ADVERTENCIAS SIMBOLOS Una conexion incorrecta del equipo puede producir la muerte lesiones graves y riesgo de incendio Lea y entienda el manual antes de conectar el equipo Observe todas las instrucciones de instalaci n y operacion durante el uso de este instrumento La instalaci n operaci n y mantenimiento de este instrumento debe ser efectuado por personal cualificado solamente El Codigo El ctrico Nacional define a una persona cualificada como una que est familiarizada con la construcci n y operaci n del equipo y con los riesgos involucrados Consultar el manual de instrucciones antes de utilizar el equipo En el presente manual si las instrucciones precedidas por este s mbolo no se respetan o realizan correctamente pueden ocasionar da os personales o da ar el equipo y o las instalaciones WARNINGS SYMBOLS Death serious injury or fire hazard could result from improper connection of this instrument Read and understand this manual before connecting this instrument Follow all installation and operating instructions while using this instrument Installation operation and maintenance of this instrument must be performed by qualified personnel only The National Electrical Code defines a qu
3. check the twisted cable Rs 485 has reliability and is will connected Terminal A Terminal B Check the R 440 configuration is charged correctly It is necessary to know the PowerStudio and connect by modem or Ethernet cable inverted Check there is 3G or GPRS coverage and if this is the case the correct modem configuration Communication with the modem can be done through an antenna or cable not invested in this case The configuration is described in the manufacturer s website http www sierrawireless com productsandservices AirLink Intelligent MaM Gate ways AirLink Raven XE aspx or in the CD that comes with the modem and depending on the telephone company SIM contracted e OTHER PROBLEMS Manual O O O If the hat keeps up even when you try to get down and there is nothing displayed when a valid card is introduced probably there is no voltage The REC2 jumped or the power supply has been interrupted upstream If the charge does not start having performed well it is probably missing the microswitch that detects the position of the hat secure closed When charge is requires and there is a rC on the display it is not a real problem The charge does not start because the card is recovering the credit That credit was saved because the previous load that card ended incidents RVE 2 amp M98238801 03 12B 23 32 CIRCUTOR RVEZ 6 6 SPAREPARIS AND RECOMMENDED TOOLS The required tools to p
4. PERICOLO ATTENZIONE WARNHINWEISE SYMBOLE Durch einen nicht sachgemaBen Anschluss der Anlage k nnen Tod schwere Verletzungen und Brandrisiko hervorgerufen werden Bevor Sie die Anlage anschlie en lesen Sie bitte das Handbuch durch und machen Sie sich dessen Inhalt klar Beachten Sie bei Einsatz dieses Instrumentes s mtliche Installations und Betriebshinweise Installation Betrieb und Wartung dieses Instrumentes m ssen ausschlieBlich von entsprechend qualifiziertem Personal vorgenommen werden Von dem nationalen Elektrocode wird eine qualifizierte Person als jemand definiert der mit der Konstruktion und dem Betrieb einer Anlage und der damit verbundenen Risiken vertraut ist Vor Inbetriebnahme der Anlage ist das Handbuch zu lesen Werden die in dem vorliegenden Handbuch mit diesem Symbol versehenen Hinweise nicht beachtet oder falsch verstanden k nnen Personensch den und Sch den an der Anlage und oder den Installationen verursacht werden ADVERT NCIAS S MBOLOS Uma ligac o incorrecta do equipamento pode provocar a morte les es graves e risco de inc ndio Leia e compreenda o manual antes de ligar o equipamento Observe todas as instru es de instala o e opera o durante o uso deste aparelho A instalac o operac o e manutenc o deste aparelho devem ser levadas a cabo exclusivamente por pessoal qualificado O C digo El ctrico Nacional define uma pessoa qualificada como uma pessoa que se encontre familiarizad
5. direction of the RS 485 Manual RVE 2 amp M98238801 03 12B 26 32 CIRCUTOR RVEZ RVE 2 XO card Outdoor recharge posts with 2 outlets mode 1 cid MERECE s EH yenmek LIE gt e Li di LO MISA d A3 34TH TD J tina y gl i Manual RVE 2 amp M98238801 03 12B 27 32 m CIRCUTOR RVE 2 XO card Outdoor recharge posts with 2 outlets mode 1 Resistance Ham 38 olde JUN amp id r s NOBN Ad EJA E Manual RVE 2 amp M98238801 03 12B 28 32 m CIRCUTOR RVEZ RVE 2 amp RVE 2 COM X2 card Outdoor recharge posts with 2 outlets mode 1 with communications VEO PP 2662 ue BluBnmH LJ 771 I 4 ha rn 3 E A E oo ADJ 30 E 7 q I 4 RR ER NE E GO BE W ALE UU Manual RVE 2 amp M98238801 03 12B 29 32 9 CIRCUTOR RVEZ RVE 2 IP Outdoor recharge posts with 2 outlets mode 1 with communications 4 HH zg lal a 1 al al dl 3d an ADL ju UL Manual RVE 2 amp M98238801 03 12B 30 32 9 CIRCUTOR RVEZ RVE 2 MOV Outdoor recharge posts with 2 outlets mode 1 with communications NON Gid 4983 TEEM iat LO E i fo AU Ui Lu TWHOILdO E Manual RVE 2 amp M98238801 03 12B 31 32 m CIRCUTOR 7 TECHNICAL
6. interrupted previous cycle Present the RFID card to the reader The system looks for the target on to the TAG code buffer Once found retrieves the value of credit that user had before the cycle was interrupted Once you update the card the display shows rC Remove the card The reader unsubscribes in the buffer the TAG code of the card p I ee Ie xS Once retrieved the credit the card is ready for a new charge cycle Manual RVE 2 M98238801 03 12B 15 32 m CIRCUTOR RVE2 5 3 MISSING CREDIT OPERATIVE 5 3 1 Star of charge cycle Present the RFID card to the reader After a while it displays the credit value If the credit is not correct the display show 00 during 2s and doesn t start any new cycle Remove the card P ee IS 5 3 2 Display indications rC Credit retrieve Ex Error x t 3 Channel indication that it is on resting time During this time there is no reading card for this channel o The output is on charge cycle if oscillates vertically Stationary cycle while standing Manual RVE 2 M98238801 03 12B 16 32 m CIRCUTOR RVEZ 6 MAINTENANCE 6 1 GENERAL DESCRIPTION The vehicles charge system RVE 2 is an electrical and mechanical set able to offer charge service safely both indoors and public places and hold a continuous use recharge service To accommodate this use and conditions the main body is stainless steel with quality painting and
7. maintenance and do not cause premature degradation RVE 2 Model Manual RVE 2 amp M98238801 03 12B 9 32 a d OEZ RVI 00S 8 OEZ OSI YONJINI JLYVd V YOd VNO ld V1 V IVO VOV4LN3 OIW SV TIVA NODINHOH 9 9 NOIDO3S OOF O CI dOlJg31SOd OS32OV VdV L l e l _ a ye m CIRCUTOR 10 32 RVE 2 amp M98238801 03 12B Manual m CIRCUTOR RVE2 4 3 ELECTRICAL INSTALLATION GENERAL CONSIDERATIONS Qualified professionals must undertake all activities related to the electrical installation regardless of whether a project is needed or not depending on the power installed This unit has been designed for its use in a single phase 230Va c RVE 2 with a 10 tolerance In any case the end user must be protected against indirect contact with a residual voltage relay DDR or differences with a sensitivity of 30mA The device already includes 30mA differential protection required so if its necessary to protect upstream it must be selective or time sensitivity The choice must be made by responsible for the design of the facility so that REBT is met and to ensure maximum system availability This device can not be installed in places where there is a risk of explosion explosive atmosphere The minimum breaking power of the automatic header switch circuit breaker must be 6kA The following layouts show the
8. 4 32 m CIRCUTOR RVE2 6 7 AUTO DIAGNOSTIC DISPLAY CODE Software version is displayed for 1 second after unit is connected to the electrical supply Indicates credit avalible when the RFID card is presented to the card reader Example 88 EE When the credit number is flashing 99 this indicates that the credit value is greater than 99 Socket 1 Allows charging regardless of avaliable credit This option only works with a suitably formatted card and the correct software upgrade in the charging equipment Socket 2 Allows charging regardless of avaliable credit This option only works with a suitably formatted card and the correct software upgrade in the charging equipment Socket 1 H indicates that the charging unit has reached the preset time limit This feature can be enabled or disabled by the factory using the charging equipment software Socket 2 H indicates that the charging unit has reached the preset time limit This feature can be enabled or disabled by the factory using the charging equipment software Socket 1 O flashing indicates the charging unit has reached the preset time allowed for a minimum charge Socket 2 O flashing indicates the charging unit has reached the preset time allowed for a minimum charge EB It draws a card of the channel 1 properly updated or insert a card that is not correct EN It draws a card of the channel 2 properly updated or insert a card that is not correct Socket 1 A segment f
9. DATA Input voltage Rate input frequency Output voltage Current metering RCCB RFID reader Temperature range IP protection Enclosure Surface Input voltage Maximum consumption Connector Dimensions Weight 8 TECHNICAL SERVICE In the event of any equipment failure or any operational queries please contact the technical service of CIRCUTOR S A CIRCUTOR SAT 902 449 459 SPAIN Rest of the world 34 93 745 29 00 email sat circutor es RVE2 230Vc a 10 o 90 60Hz input voltage integrated meter 30mA 40A self reclosing ISO 14443A 10 60 C IP54 INOX AISI 304 2mm thickness RAL 9006 gray polyester 230Vc a 10 o 7 2kW 2 x SCHUKO 16A o 214mm 1230mm 24 7 kg CIRCUTOR SA Vial Sant Jordi s n 08232 Viladecavalls Barcelona Tel 34 93 745 29 00 Fax 34 93 745 29 14 Web www circutor com email central circutor es CIRCUTOR reserves the right to modify the content of this manual without prior notification Manual RVE 2 amp M98238801 03 12B 32 32
10. RVE 2 complies with the CE requirements and the current European Union directives for this type of equipments The main standards that have been taken into account during the design phase are as follows UNE EN 62196 1 Bases sockets vehicle coupling devices and vehicle access points Electric vehicle conductive charging Part 1 Charging electrical vehicles of up to 250A in alternating current and 400A in direct current UNE EN 61851 1 Electric Vehicle Conductive Charging System Part 1 General requirements UNE EN 61851 21 Electric Vehicle Conductive Charging System Part 21 Requirements of the electric vehicle for its conductive connection to the main in A C and D C UNE EN 61851 22 Electric Vehicle Conductive Charging System Part 22 A C charging station for electric vehicles Other Standards IEC61000 IEC60364 4 41 IEC60884 1 IEC61010 UNE EN55011 ISO14443A This unit has been designed for outdoor use It has an IP54 protection degree in accordance with ANSI IEC 60529 2004 Manual RVE 2 M98238801 03 12B 7 32 m CIRCUTOR RVE2 3 SAFETY INFORMATION Do not use connection cables that are not in perfect working order Do not use the RVE 2 for other uses that have not been specified in its design i e for any application that is unrelated to charging electric vehicles Do not modify the RVE 2 unit In case the unit is modified the warranty will be void and CIRCUTOR shall not be liable for any future malfunctio
11. S VERIFICA MON Sd ts 9 4 2 ANCHORING AND DIMENSIONS ccccccccccesesesecceeeeecaeeeseceeeeeeseeeesecceeeeeseeaeseeeeeeeeessaeeuseeeeeeesssaaseeeeeeesessenaaasses 9 4 3 ELECTRICAL INSTALLATION GENERAL CONSIDERATIONS eee 11 4 3 1 16 A Single phase electrical installation RVE 2 Mode 1 12 9 ME GUIDE u uuu u tit inten era O 13 5 1 NORMAL CHARGE OPERATIVE RENT 13 5 1 1 tl OL Rei ae Cy eee ia ic salca sona sami E DR RR esini E 14 5 1 2 End of charge cycle Normal end arsas na 14 5 1 3 Endofchargecyclefendofcred i eee aaa aneen 14 5 1 4 Endofchargecycle missingchargeend eee aaa 15 5 2 RETRIEVE CREDIT OPERATIVE uuu uuu ll nil alk clio 15 6 2 1 Card interrupted Previous CVClO ts 15 5 3 MISSING CREDIT OPERATIVE eee 16 5 3 1 Q Ol Chalge Vitis 16 5 3 2 Dis pay NACA ONS m S 16 b MAINTENANCE uuu see uu E E A 17 6 1 GENERAL DESGRIPTION u M TRU u 17 6 2 DIAS SEO tias 18 6 3 PAS SEMI EIN rancios 20 6 4 PREVENTIVE MAINTENANCE cresta diia rita 21 6 4 1 MOD arre E iia e a a o samasaa 21 6 4 2 1 O y OPONE OZ Po
12. a com a constru o e opera o do equipamento assim como com os riscos inerentes Consultar o manual de instru es antes de utilizar o equipamento No presente manual se as instru es que precedem este s mbolo n o forem respeitadas ou realizadas de forma correcta podem ocorrer ferimentos pessoais ou danos no equipamento e ou nas instala es AVVERTENZE SIMBOLI Un collegamento errato del dispositivo pu provocare morte lesioni gravi nonch rischio di incendio Prima di collegare il dispositivo leggere attentamente il manuale Osservare tutte le istruzioni relative all installazione e all operativit durante l uso di questo strumento L installazione operativit e manutenzione di questo strumento devono essere realizzate solamente da personale qualificato Il Codice Elettrico Nazionale definisce una persona qualificata come colui che ha familiarit con la costruzione e operativit del dispositivo e con i rischi che ne possano derivare Consultare il manuale di istruzioni prima di utilizzare il dispositivo Qualora le istruzioni riportate nel presente manuale precedute da questo simbolo non vengano osservate o realizzate correttamente possono provocare danni personali o danneggiare il dispositivo e o gli impianti Manual RVE 2 M98238801 03 12B 3 32 9 CIRCUTOR RVEZ CONTENTS T OVERVIEW RR a asas 5 FSS TEMDESCRIP T a laa 6 3 SAFETY INFORMATION 2 UI Ia sassa 8 4 INSTALLATION EN 9 4 1 PREVIOU
13. alified person as one who has the skills and knowledge related to the construction and operation of the electrical equipment and installations and who has received safety training on the hazards involved Consult the instruction manual before using the equipment In this manual if the instructions preceded by this symbol are not met or done correctly can cause personal injury or equipment damage and or facilities WARNHINWEISE SYMBOLE Un branchement incorrect de l appareil peut entrainer la mort ou des l sions graves et peut provoquer un incendie Avant de brancher votre appareil lisez attentivement le manuel et assurez vous de bien avoir compris toutes les explications donn es Respectez toutes les instructions concernant le mode d installation de l appareil et son fonctionnement L installation le fonctionnement et la maintenance de cet appareil doivent tre r alis s uniquement par du personnel qualifi Le code lectrique national d finit en tant que personne qualifi e toute personne connaissant le montage et le fonctionnement de l appareil ainsi que les risques que ceux ci comportent Consulter le manuel d instructions avant d utiliser l appareil Si les instructions suivantes pr c d es dans le manuel d un symbole ne sont pas respect es ou sont r alis es incorrectement elles pourront provoquer des dommages personnels ou abimer l appareil et ou les installations 9 CIRCUTOR RVEZ ACHTUNG PERIGO
14. coating anti graffiti Overall protection is IP54 Charging systems MODE1 model the hat can be hat can be seen and in its upper position allows access to the connection area and at its lowest position protects the connectors and prevents tampering A M Muelle 4 AA AAA 1 gt LN Rip Electroiman 3 B resi N o J I V Ll eh Lo Tope el stico 1 Anillo el stico 2 l Arandela 6 With the energy stored in the spring 4 the hat can gets up which the user previously had supplied closing the post The hat keeps closed by an electromagnet 3 When the reader recognizes a card and it is valid the electromagnet is deactivated for a 1s so the hat gets up Manual RVE 2 amp M98238801 03 12B 17 32 m CIRCUTOR RVE2 6 2 DISASSEMBLY To get access inside the charger is necessary to open the back lid depending on model with Allen screws Once RVE is opened the electrical devices are able to be manipulated and the guidance system hat To continue with the removal follow the following sequence 1 Disconnect the power supply before disconnect electrical intervention Only trained personnel are authorized and with the precautions and appropriate personal protective equipment Lock the main switch on the distribution main to avoid the self reclosing of it or by others inadvertently If necessary include a warning note If its not p
15. connect the charge and get the hat down The credit not consumed is retrieved to the card xx Displays the credit xx Remove the card End of charge cycle end of credit If its displayed o stopped indicate that the system has stopped the charging cycle Digit 1 channel one NO active Digit 2 channel two NO active Present the RFID card to the reader and the hat gets up Disconnect the charge and get down the hat The credit is retrieved to the card 00 Display shows the credit 00 Remove the card Manual RVE 2 amp M98238801 03 12B 14 32 CIRCUTOR RVEZ 5 1 4 End of charge cycle missing charge end bb m II 1 If it s displayed o stopped indicate that the system has stopped the charging cycle Digit 1 channel one NO active Digit 2 channel two NO active Present the RFID card to the reader The hat gets up Disconnect the charge and get down the hat The credit not consumed is retrieved to the card xx Display shows the credit xx Remove the card Oo 0 A0 This end of charge can only be given one minute past the start of the cycle if there is no power consumption 5 2 RETRIEVE CREDIT OPERATIVE Following Interruption of the charging cycle through no fault of the user After the interruption outside the client when it returns to recover the debt it is available whether or not in use the unit for another client the following operations 5 2 1 Card
16. e and neutral are connected to the RCD REC2 and earth ground to terminal as shown in the picture NEED e i PEZ NEUTRAL 12 32 Manual RVE 2 amp M98238801 03 12B m CIRCUTOR 5 USER GUIDE MODE 1 posts model RVE 2 Conectar Connect 5 1 NORMAL CHARGE OPERATIVE The following explanation refers to loans used but as a symbol In countries where the currency has a similar magnitude to the EURO can be considered as 1 or 1 credit In countries where the currency is very different order of magnitude to the EURO a conversion can be easily calculated which for example is 1 credit 1000 local units In that case speaking of credit makes more sense Manual RVE 2 amp M98238801 03 12B 13 32 CIRCUTOR RVEZ AoA WD Start of a charge cycle Present the RFID card to the reader After a while displays the credit value If the claim is correct a deposit is deducted from the card 16 credits default and transferred to the charge The hat gets up The flashing led indicates the power socket available Connect the charge Get down the hat Remove the card The system connects the power and starts the control of credit as the energy consumed The display shows a segment simulating a twisting motion with a speed proportional to power output End of charge cycle Normal end Present the RFID card to the reader Cycle is interrupted and the hat gets up Dis
17. e that the RCCB works correctly We recommend test it causing a current leakage in one plug is not necessary to test it on both The test can be done to different ways to choose 1 Open the lid and get into de REC2 Press the test button if it reset itself it runs correctly 2 By a deliberated leak through a special device able on request This works by a switch which causes a current leakage When the pilot is lit pressing the button for approximately 1s the REC2 should be jumped Then give up the button The hat has to be moved up so you can remove it without problems After a few seconds REC2 restart and will be displayed the two digit display version number of firmware Move down the hat The test is finished 6 4 2 Yearly REMEMBER TO REMOVE POWER Dothe monthly REC2 preventive maintenance Check the electrical wiring is correctly there are no obvious faults in the insulation or defects on the components Check the proper tightening of the screws on the power components especially the REC2 and circuit breakers to which access is provided Use the right tool on each case Move down and leave the hat to get up Look at the shock absorber if it s soft enough and his movement too If necessary do a test twice Check the movement peaces and the shock absorber olf the shock absorber is not enough proceed to replace it olt is not necessary use a lubricant in any movement parts General cleaning on the electrical comp
18. ed energy is low Now all the mechanisms of team are accessible Manual RVE 2 amp M98238801 03 12B 19 32 gj CIRCUTOR RVE2 6 3 ASSEMBLING 1 Carry out the same steps in reverse order of removal The elastic ring can usually be easily assembled by hand 2 DO NOT FORGET THE GROUND CABLE RECONNECTION after the elastic ring assembling 5 3 To proceed to testing REC2 should be reconnected again 4 ATTENTION WITH THE REC2 CONNECTION PROCESS a If the power supply was cut upstream supply the devices to test the RCCB If it is not possible to supply it just raise the handle to rearm the REC2 and move the red protection cover to the left b Replace the cover and set it correctly If there is power we will use to test the function of the HEC2 reset before the end of the operation After a few seconds the REC2 should reset itself c If long time passed between the disconnection operations REC2 should do the sensitivity REC2 test again as indicated in the previous section Proceed to press the test button If all is correct the REC2 automatically reset after a few seconds d If keeps not running treat the incident as a failure with the protocol established by those 5 Replace the lid and set it correctly Manual RVE 2 M98238801 03 12B 20 32 gj CIRCUTOR RVE2 6 4 PREVENTIVE MAINTENANCE The recommended preventive maintenance and his frequency is the following 6 4 4 Monthly Sensibility test Make sur
19. erform proper preventive or corrective maintenance are the normal installation electrician The PPE Personal Protective Equipment are also common and should be designed by the Prevention Service employee responsible who makes the assistance The following mentioned tools are the only not commonly used e Flat brush with long hair e Special tool to cause a current leakage The amount and type of recommended spare parts are described in the following list Main card control If this card is replaced also replace the toroidal The spare card brings its own toroidal We recommend having 1 unit per 10 RVE 2 Auxiliary card If it is replaced also replace his toroidal The spare card brings its own toroidal We recommend having 1 unit per 10 RVE 2 Plug bases We recommend having 2 units per 10 RVE 2 REC2 Check the sensibility of the RCCB is 30mA 20 030A We recommend having 1 unit per 10 RVE 2 Circuit breaker We recommend having 2 units per 10 RVE 2 Power relay We recommend having 2 units per 10 RVE 2 Overcurrent protector We recommend having 2 units per 10 RVE 2 Shock absorber limits retaining rings and washers Is the material which has a mechanical weak before We recommend having 10 units per 10 RVE 2 Allen screws of the lid We recommend having 30 units per 10 RVE 2 Electromagnet We recommend having 1 unit per 10 RVE 2 Rotary microswitch We recommend having 2 per 10 RVE 2 Manual RVE 2 amp M98238801 03 12B 2
20. idal transformer is probably assembled incorrectly Solution Check and correct if necessary It could be problems with the corresponding card energy control the main or auxiliary If it is appropriate replace it remember that it must also replace the corresponding toroidal transformer Attention to assembling the toroidal transformer because it has polarity The ground wire must pass the toroidal brown side It is also important whatever the type of electronic card to replace to verify that the original bridges have inserted and reproduce in the spare card Do not replace any card under supply or with a different type o If there is no reaction when the card is inserted and the hat is still down probably it not recognize the card or it is empty Manual RVE 2 M98238801 03 12B 22 32 CIRCUTOR RVEZ e COMUNICATION PROBLEMS MOV IP o COM Posts The communication follows always the same order X2 communicates with R 440 R 440 communicates with modem Modem communicates with the network Obviously the posts which don t have R 440 or modem do not apply to them what Is said o Behind a communication interruption check as the following order depending with the material that the RVE 2 incorporates The COM led of the X2 card Works correcily see on electrical wirings peg The communication with R 440 works when is flashing When the R 440 communicates with the X2 the led Tx and Rx are flashing case that doesn t work
21. ixed in one position indicates there is no load When the segment is rotating it indicates charging The speed of the rotation indicates the amount of load Socket 2 A segment fixed in one position indicates there is no load When the segment is rotating it indicates charging The speed of the rotation indicates the amount of load riC Credit recovery failed in a previous cycle Reset the system E Communication failed with RFID card reader RFID Reader unable to read card E E RFID Reader unable to write to card The information that appears briefly in the card reader display shows the firmware version number i e 29 is version 2 9 Errors E1 E2 E4 have automatic recovery Manual RVE 2 amp M98238801 03 12B 25 32 mg CIRCUTOR RVEZ 6 8 ELECTRICAL WIRING X2 Card Topographic distributions TOROIDAL CIRCARLIFE X2 M DULO DE 1 toma JUMPER CONFIGURACI N 1 2 tomas LED TOMA 1 ELECTRO LED LED IMAN GPU COM O pilona 1 caja mural CS O sin det proximidad 1 con detector Reset Par metros de comunicaci n Solo tras PowerUp DISPLAY 1 Rs 485 twisted cable connection Terminal A brown Terminal B white RS 485 TACHNICAL CHARACTERISTICS 57600095 Default address Default n of nodes 98 Stop bi The number of nodes must be changed when it is integrated into a network by factory default is set at 98 the same goes for the
22. le phase with two outlets 230Va c 16A 3 6kW with RS485 and IP communications o RVE 2 MOV Outdoor recharge posts single phase with two outlets 230Va c 16A 3 6kW with RS485 and IP communications Motorised MCB and Surge protection Manual RVE 2 amp M98238801 03 12B 6 32 gj CIRCUTOR RVE2 Comparing with a simple plug RVE 2 offers the following Safe collection of energy for the installation s operator Prevents fraud and misuse Reliable measurement system for the user since only the energy consumed is paid with an accurate reading of the energy consumed Protects end user against electrical risks Current is only present in a non interrupted charging cycle The system is not powered during all other cycles Current theft prevention function The operation is interrupted if the socked is removed during the charging process so that no more energy will be supplied to the base until the user is identified again Ensure the power supply is stopped before the physical disconnection of the connector Intelligent charging process off peak hours distribution of power available etc when complemented with the PC and in hourly discrimination periods The system is complemented with Pre paid cards Available without credit to recharge later and pre charged units of credit Pre paid card writer There are two models available o Compact RVE Term o Software version with USB peripheral RVE Soft The
23. n otrictly follow the current safety regulations Do not repair or install elements while the unit is powered Only authorised and trained personnel can access the elements powered with voltages inside the unit Check the operation of the earth leakage relay periodically at least once a month and always after maintenance operations The installation must be checked once a year by qualified personnel Any unit with defects or faults that could represent a risk to the user must be removed from service broken plugs lids that do not close etc Do not use spare parts that are not original of CIRCUTOR Manual RVE 2 M98238801 03 12B 8 32 mg CIRCUTOR RVEZ 4 INSTALLATION 4 1 PREVIOUS VERIFICATIONS e Make sure that the materials have not been damaged during transport e Make sure that the voltage used on the board is suitable for the place country where it will be operating e Make sure that the connection bases are suitable for the place country where the unit will be operating 4 2 ANCHORING AND DIMENSIONS The RVE 2 is a charge system designed to be anchored on floor For the anchoring is provided a template and nuts with bolts to leveling The bolts provided for the anchor must be inserted into a concrete base resistance equal to or greater than IK8 It is recommended to leave overhang surface bolts from 20 25 mm for a good anchor with the post NOTE Must use Allen wrench to screw supplied appliances for proper
24. onents area and the lower hat area Remove with a brush the dust Clean inside the card reader with the brush or o tissue Check the connection state base is correct Manual RVE 2 amp M98238801 03 12B 21 32 gj CIRCUTOR RVE2 65 CORRECTIVE MAINTENANCE 6 5 1 Problems Causes Solutions e HAT PROBLEMS ASSOCIATED o f it sometimes necessary to exert a light force at the time the card is inserted for takeoff then open it normal then the electromagnet 3 has remanence Solution Replace it o If the hat doesn t get up itself is because it is assembled incorrectly or the resort is deteriorated 4 Solution Replace it o f the hat is locked it probably shorted out the drive transistor Solution Replace the main control card o If the hat makes noise when gets the top then it probably had damage the elastic limit 1 Solution Replace it o If it can be removed the hat out of the post then it has broken the elastic ring 2 or improperly installed Solution assembly correctly or replace it o If the hat does not stay in its closed position probably caused by one of the following anomalies Dirt between the electromagnet and the board Clean the area thas been interrupted internal electromagnet winding Solution Replace it The transistor who supplies the electromagnet crashed Solution Replace the main control card e METERING CURRENT PROBLEMAS o If no credits discounts despite consumption Then the toro
25. ossibly to take the whole power supply for example because there are others posts on charge disconnect the power supply from local area through de RCCB REC2 PHASE NEUTRAL GROUND PHASE NEUTRAL Manual RVE 2 amp M98238801 03 12B 18 32 CIRCUTOR RVEZ ATENTION WITH THE REC2 DISCONNECTION PROCESS It has to be active removing the protection cover to the right in that way it wont restart and then pressing the test button This test will show if the RCCB works correctly sensibility Is recommended to do in each intervention If the RCCB has not jumped stop until the fault has been repaired by trained personnel Remember that the test button does not work if the residual circuit breaker is not powered Leave the REC2 red cover on the right during the operation Remember that the REC2 input terminals can be powered so it has to be careful to avoid manipulation closer it Do not do any operation if there are faulty cables insulation damage or vulnerability of any party liable to be powered 2 Disconnect the ground cable with ring terminal connected on the axis end 5 Do not allow to fall over the screw 3 With one hand get down the hat making accessible the elastic ring 2 on the end of the drive shaft 5 and keep it there With the other hand take out the elastic ring with a screwdriver 6 and the shock absorber top 1 4 Leave the hat slowly Attention with the resort is not projected out even the stor
26. outline of the installation in blocks They are shown for information purposes only The installation company will be responsible for dimensioning the section protection elements and lengths in compliance with the current regulations There is a ground terminal that must be properly wired to the conductor with the minimum section of 6mm IT IS VERY IMPORTANT ITS RIGHT CONNECTION AND ITS DIMENSIONS The minimum section of the conductors must be 6mm but that will be in function of the installation conditions length ducts may be higher Consult REBT or the appendices The responsibility for the installation corresponds to the authorized installer that designs and makes Depending on the model the device is able to communicate by Rs 485 compatible devices so it will be able to send and receive commands or information The RS 485 network installation must follow the requirements that the standard prescript among others the linear topology end of line resistor shielding equipotential mass Such communication can be enhanced by connecting to R 440 module or multipoint system data can then be stored and accessed via Ethernet Diagrams and technical information can be found in paragraph 6 of Maintenance Manual RVE 2 amp M98238801 03 12B 11 32 9 CIRCUTOR RVEZ 4 3 1 16 A Single phase electrical installation RVE 2 Mode 1 RVE2 equipment installation consists of connecting the outlet of 230V single phase The phas

Download Pdf Manuals

image

Related Search

Related Contents

  Agisoft PhotoScan User Manual - Professional Edition, Version 1.2  MANUAL DE INSTALACION  Manual de Usuario - Emmegi Ricambi SpA  ANNEXE 4 - Agora21  Guia do Usuário Termômetro Registrador de  Horno de microondas de 1.2 pies cúbicos - Acero inoxidable  Manual de Instrucciones  321 Studios Enforcer SA-026 User's Manual  