1. All rights reserved by NEO Electronics Corporation Upgrading with this method is not necessary if the version is C shaded portion in example below MINICUBE 2000 C F W V1 00 Control Board 0001 01 00 I O Board 0100 01 00 01 02 4 Click the OK button to close the About dialog box 5 Terminate the ID78KOS QB ZBG CD 07 0061 Attachment 3 9 2 2 Preparation of upgrade file 1 Download the upgrade file gb 78kOskx1mini_c_dl exe from the Development Tools Download page at the NEC Electronics website URL http www necel com micro ods eng Click Version up Service Category Each Development Tool MINICUBE_ Software Product Name QB 78KOSKX1MINI Version Rev C 2 The downloaded file is the self extracting type file gb 78kOskx1mini_c exe Execute gb 78k0skx1mini_c exe first to decompress the following files in the same folder a IEQBUTL exe IECUBE utility b IEQBUTL ini Environment setting file c MINICUBE_firmware_78KOSKX1_ V100 hex Firmware data d MINICUBE_FPGA_78KOSKX1_V102 xsvf FPGA data e ZUD CD 07 0144 pdf How to Upgrade QB 78KOSKX1MINI Japanese f ZUD CD 07 0144 e pdf How to Upgrade QB 78KOSKX1MINI English g ZUD CD 07 0136 pdf Operating Precautions Japanese h ZUD CD 07 0136 e pdf Operating Precautions English ZBG CD 07 0061 Attachment 4 9 2 3 Updating firmware data 1 Connect the QB 78KOSMINI to the host machine using a USB cable 2 Turn on the power to the QB
2. period expires an upgrade will be available for a fee We therefore recommend that you take advantage of the free upgrade offer during the free upgrade period ZBG CD 07 0061 Attachment 1 9 How to Upgrade QB 78KOSKX1MINI 1 Overview 1 1 Upgrade overview This document describes the method for user implemented upgrading of the QB 78KOSKX1MINI Target product QB 78KOSKX1MINI control code 1 A B Control Code Upgrade Method Control Code Before Upgrade After Upgrade QB 78KOSKX1MINI A B Upgrade by user or upgrade by sending the product to C NEC Electronics The following item is modified by upgrading QB 78KOSKX1MINI from control code A and B to C Note 2 Note 3 e Correction of the following bug A program does not stop at a software breakpoint Notes 1 The control code is the second digit from the left in the 10 digit serial number If the product has been upgraded the control code can be checked by selecting About from the Help menu of the integrated debugger ID78KOS QB X in version information MINICUBE 2000 X F W V is the control code Open the About dialog box in either of the following ways e Select About under Help from the menu bar on the main window e Press the ALT H and A keys in that order NEG Integrated Debueeer ID 78K05S QB Version W290 3 Aue 2006 FOROS MINICUBE Executor V2 0 OCD Control Code 1 01 MIN ICUBE 200 B F 7 1 00 Control Board
3. 0001 01 00 LO Board 0100 01 00 01 01 GopyrighttG NEG Electronics Corporation 1993 2006 All rights reserved by NEG Electronics Corporation 2 Refer to QB 78KOSKX1MINI Control Code A B C Operating Precautions ZUD CD 07 0136 for details on bugs 3 The bugs will not be corrected even if the product is upgraded if these procedures are followed for any other products beside the target version ZBG CD 07 0061 Attachment 2 9 1 2 Operating environment for upgrade The IECUBE utility IEQBUTL exe which is used for upgrading operates under the following environments Installation of the latest Service Pack is recommended e Windows 2000 e Windows XP Home Edition e Windows XP Professional 2 Upgrade Procedure 2 1 Confirmation of current version before upgrade 1 Connect the QB 78KOSMINI to the host machine using a USB cable 2 Turn on the power to the QB 78KOSKX1 DA and start the ID78KOS QB 3 Confirm that the control code of the QB 78KOSMINI is A or B in the About dialog box Open the About dialog box in either of the following ways e Select About under Help from the menu bar on the main window e Press the ALT H and A keys in that order NEC Integrated Debueger ID78K0S QB Version W290 3 Aug 2006 TOROS MINICUBE Executor e 02 OLD Control Code 1 01 PE Pe MIN TCUBE 200 By We W100 Control Board 001 01 00 I0 Board 0100 01 00 01 01 Copyrighti NEG Electronics Corporation 1993 2006
4. 78KOSKX1 DA 3 Start the IECUBE utility IEQBUTL exe 4 Select the F W tab confirm the following settings and then click the START button e QB 78KOSKX1MINI Control Code_C is selected in the File Name combo box e The Download radio button is selected BE IEQBUTL SELF TEST F M FPGA D Temp File Name QB 76KOSKXI MINI Gontrol Gode CG HEX File Name MINICUBE firmware TOROS W100 hex f Download Co Verity Caution Do not browse or select firmware data using the PATH button if you do so firmware data is not set normally Be sure to start the IECUBE utility IEQBUTL exe from the folder in which the other upgrade files are stored 5 The following message will be displayed Click the OK button IEQBUTL IEQRUTL MINIGUBE FEROS was connected z File Name MINICUBE tirmware To k0S ked w100 hex Start download ie Sian 2004 0 07 233054 z start Address O00000h PES rok MEE onire ade e 1012h Control Board 0007 01 00 00711 4h a edb ZBG CD 07 0061 Attachment 5 9 Caution Do not turn off the power to the QB 78KOSKX1 DA nor disconnect the USB interface cable from the QB 78KOSMINI during downloading otherwise it will not be possible to restart the QB 78KOSMINI The time required for downloading is approximately two minutes If an abnormal state occurs such as no response getting sent from IEQBUTL for more than 10 minute forcibly terminate IEQBUTL turn off the power to the QB 78KOSKX1
5. DA disconnect the USB interface cable from the QB 78KOSMINI then start from step 1 again 6 The following message will be displayed when downloading is complete Click the OK button EC IEQBUTL SELF TEST FAW FPGA DT emp ile Hame IEQBUTL HES File Mame Download C Verity T E 7 Click the EXIT button 8 Turn off the power to the QB 78KOSKX1 DA and then disconnect the USB interface cable from the QB 78KOSMINI Caution Be sure to turn off the power to the QB 78KOSKX1 DA and disconnect the USB interface cable from the QB 78KOSMINI after the firmware data has been updated Turn on the power again then the update the FPGA data with new firmware If the FPGA data is updated after the firmware data is updated without first powering the QB 78KOSMINI off and on again the IECUBE utility IEQBUTL exe will hang ZBG CD 07 0061 Attachment 6 9 2 4 Updating FPGA data 1 Connect the QB 78KOSMINI to the host machine using a USB cable 2 Turn on the power to the QB 78KOSKX1 DA 3 Start the IECUBE utility IEQBUTL exe 4 Select the FPGA tab confirm the following setting and then click the START button e MINICUBE_ FPRPGA_78KOSKX1_V102 xsvf is selected in the File Name combo box BE IEQBUTL SELF TEST FAW FPGA D4 Temp PATH File Name MINICUBE FPGA SK0SKX1_VO102xsvt m FPGA File Name MINIGCUBE_FPGA_f kKOSRal VO02 xevt MINICUBE FEROS was connected gt wi Start download Caut
6. Microcontroller Technical Information Document No ZBG CD 07 0061 QB 78KOSKX1MINI September 6 2007 In Circuit Emulator for Low Pin Count Issued by Microcontrollers 78KOS KA1 78KOS KB1 78KOS KU1 78KOS KY 1 Development Tool Solution Group Multipurpose Microcomputer Systems Division Microcomputer Operations Unit NEC Electronics Corporation Upgrade Related documents Notification _ QB 78KOSKX1MINI User s Manual classification U17272EJ4VOUMOO QB 78KOSKX1MINI In Circuit Emulator for Low Pin Count Microcontrollers 78KOS KA1 78KOS KB1 Usage restriction Upgrade Document modification 78KOS KU1 78KOS KY1 Usage Restrictions Other notification ZBG CD 07 0052 1 Target product and version Control Code Upgrade Method QB 78KOSKX1MINI In circuit emulator for low pin coun A Upgrade by user or upgrade by sending the microcontrollers 78KOS KA1 product to NEC Electronics 78KOS KB1 78KOS KU1 78KOS KY 1 It is not necessary to upgrade control code C 2 Upgrade details Restriction No 3 and specification No 2 described in QB 78KOSKX1MINI In Circuit Emulator for Low Pin Count Microcontrollers 78KOS KA1 78KOS KB1 78KOS KU1 78KOS KY1 Usage Restrictions ZBG CD 07 0052 will be corrected or implemented After upgrading the control code will be C See the document for details 3 Upgrade start date Two types of upgrade are available upgrade by user and upgrade by sending the pr
7. e About dialog box Open the About dialog box in either of the following ways e Select About under Help from the menu bar on the main window e Press the ALT H and A keys in that order NEC Integrated Debugger ID FER OS LI6 Version W300 20 Mar 2007 FOROS MINICUBE Executor 2 04 OCD Control Code 1 01 MINICUBE 2000 C FW 1 00 Control Board 000I 01 00 IZO Board 0100 01 00 01 02 hd Copyrighti HEC Electronics Corporation 19939 2007 Gil rights reserved by NEC Electronics Corporation Confirm that the version is as shown below shaded portions MINICUBE 2000 C F W V1 00 Control Board 0001 01 00 I O Board 0100 01 00 01 02 3 Click the OK button to close the About dialog box 4 Terminate the ID78KOS QB Upgrade is thus completed ZBG CD 07 0061 Attachment 9 9 3 When Upgrading Failed Consult an NEC Electronics sales representative or distributor if upgrading failed such as in the example described below using the procedure described in this document e Updating described in 2 3 Updating firmware data or 2 4 Updating FPGA data cannot be performed normally Example 1 When downloading firmware data as described in 2 3 downloading stops before all the data has been downloaded No matter how many times the procedure is repeated from step 1 the result is the same Example 2 When downloading FPGA data as described in 2 4 downloading stops before all the data has been downloaded No mat
8. ion Do not turn off the power to the QB 78KOSKX1 DA nor disconnect the USB interface cable from the QB 78KOSMINI during downloading otherwise it will not be possible to restart the QB 78KOSMINI The time required for downloading is approximately two minutes ZBG CD 07 0061 Attachment 7 9 If an abnormal state occurs such as no response getting sent from IEQBUTL for more than 10 minutes forcibly terminate IEQBUTL turn off the power to the QB 78KOSKX1 DA disconnect the USB interface cable from the QB 78KOSMINI then start from 2 3 Updating firmware data again 6 The following message will be displayed when downloading is complete Click the OK button Eo IEQBUTL SELF TEST FAW FPGA D4 Te mip Complete Please power off the target 2634014 2634014 TTT TTT T E 7 Click the EXIT button 8 Turn off the power to the QB 78KOSKX1 DA and then disconnect the USB interface cable from the QB 78KOSMINI Caution Be sure to turn off the power to the QB 78KOSKX1 DA and disconnect the USB interface cable from the QB 78KOSMINI after the FPGA data has been updated Turn on the power again and then start the ID78KOS QB If the ID78KOS QB is started after FPGA data is updated without first powering the QB 78KOSKX1 DA off and on again the ID78K0OS QB will not operate normally ZBG CD 07 0061 Attachment 8 9 2 5 Confirmation of version after upgrade 1 Start the ID78KOS QB 2 Confirm the version information in th
9. oduct to NEC Electronics Both methods are available but we request customers to upgrade by themselves because upgrades by sending the product to NEC Electronics may require two weeks or longer Note The control code is the second digit from the left in the 10 digit serial number If the product has been upgraded the control code can be checked in the About dialog box in the ID78KOS QB X in version information MINICUBE X F W V is the control code ZBG CD 07 0061 2 2 3 1 Upgrade by user Downloading through Development Tools Download is possible from September 18 2007 Download the latest version of the upgrade file containing firmware FPGA data etc from the Development Tools Download page at the NEC Electronics website and upgrade the product by referring to How to Upgrade QB 78KOSKX1MINI ZUD CD 07 0144 which is included with the upgrade file URL http www necel com micro ods eng Click Version up Service Category Each Development Tool MINICUBE _ Software Product Name QB 78KOSKX1MINI Version Rev C 3 2 Upgrade by sending the product to NEC Electronics Upgrading by sending the product will be available from September 18 2007 Upgrade by sending the product to NEC Electronics is available Consult an NEC Electronics sales representative or distributor The upgrade described herein will be provided for free for a period of one year from the above date After the free upgrade
10. ter how many times the procedure is repeated from 2 3 the result is the same e The procedure in 2 5 Confirmation of version after upgrade cannot be performed normally Example 1 The ID78KOS QB does not start Example 2 The version information shown in the About dialog box differs from that shown in the illustrations