1. SPECIFICATIONS TECHNICAL SPECIFICATIONS MODEL SW PRO 800 SW PRO 1 100 SW PRO 1 600 SW PRO 2 200 INPUT hases 1 Ph OUTPUT oltage regulation batt mode 10 requency Range 60 Hz o 50 Hz 1 Hz ransfer Time from normal to Batt mode lt 3ms typical Wave form Perfect Sinewave BATTERIES ype Valve Regulated Lead Acid untime typical with PC TFT 17 4 hours to 90 cap PROTECTIONS Full internal protections UPS overload Shortcircuit Batt overcharging Surge Suppression 310 J Internet Data Line RJ11 RJ45 DISPLAY INDICATIONS Working Mode Normal or Battery Battery level Load level Input output Voltages Alarms Zbeeps s beep 2s UPS Fault Continuos Beep PHYSICAL INFORMATION 350 146x 160 as o m 22 B Nema 5 16R WORKING CONDITIONS 0 90 0 40 C No Condensing COMMUNICATION USB Serial RS 232 Opcional Windows family Linux Unix Mac OSX Specifications may change without further notice USA Headquarters EUROPE Headquarters Latin America Headquarters 10540 NW 26th St Ave Can Bordoll 60 Nave 4 Zona Ind San Vicente Il C F A11 Doral FL 33172 USA Sabadell 08202 SPAIN Maracay Venezuela Tel 1 305 406 3664 Tel 34 93 745 9694 Tel 58 243 551 7023 www integra ups com 1303 SWPRO_800 2200 ENG 7
2. series offers 4 different UPS models all of them interactive type with internal automatic voltage regulation and sinewave output in battery mode Input Voltage Vac Output Voltage Vac AC MODE indicator Load Level OVERLOAD indicator BATT MODE indicator Y _ g AC MODE fO ovenioann fE Battery level LoadLevel 4 att Leve O LOW BATT indicator FAULT indicator LCD ON OFF switch Outlets Salidas AC Input Entrada CA Input Breaker RJ 45 USB RS232 4 INSTALLATION TO MAKE SURE UPS WILL BE ABLE TO OFFER YOU EXPECTED BACKUP FIRST TIME PLUG UPS TO AC SOURCE DURING 4 TO 6 HOURS TO ALLOW RECHARGING INTERNAL BATTERIES e This product leaves factory with battery fully charged however during transportation and storage it may loose a non determined part of its charge therefore we recommend plugging it to Power Line for 6 hours before using the UPS e Install this unit in any protected environment with a dust free air flow Also corrosive vapours and conductive contaminants must be avoided Do not use UPS outdoors or where either temperature or humidity exceeds tech specs Install UPS at least 10 inches away from your monitor to avoid magnetic interference e Connect phone or LAN cable to RJ11 45 Jack Identified as IN and your Router or PC RJ45 port to RJ 11 45 Jack I
3. SW PRO 800VA 2 200VA USER MANUAL USER MANUAL SW PRO 800 1100 1600 2200VA UPS SAI SINEWAVE INTERACTIVE Technical information on this manual is property of INTEGRA This manual Information cannot be copied or distributed totally or partially without written approval of INTEGRA INTEGRA can introduce modifications in their products or manuals without further notice INTEGRA is not responsible of mistakes or missing information in this manual INTEGRA is not responsible for wrong use a third part can do of this information Trademarks and logos in this manual are property of their owners fc SW PRO 800VA 2 200VA USER MANUAL 1 SAFETY INSTRUCTIONS WARNING This product has been designed to operate safely and reliably for years Nevertheless as it is an electrical device it is required to read and understand this manual Keep manuals as references for future consults WARNING This product has been designed to be used indoors protected of water direct sun light and extreme temperatures This device must not be used outdoors close to moisture of heat sources WARNING Do not set objects on this UPS Handle with care Do not block UPS ventilation WARNING Make sure to connect this unit to proper power line according to selected model The UPS Technical Specs sticker shows power rating information DO NOT connect this UPS to any of its own power ouilets WARNING UPS must be installed following instruction from thi
4. dentified as OUT Plug UPS to a power outlet with a proper grounding Connect your equipments to UPS power outlets e NEVER connect equipments with power consumption higher than Power Capacity of this UPS such as Laser Printers or copiers THIS KIND OF UPS IS NOT COMPATIBLE WITH GENERATOR POWER PLANTS DO NOT CONNECT TO ELECTRICAL SUORCE SUPPLIED BY GENERATOR POWER PLANTS SINCE UPS WILL NOT WORK PROPERLY www integra ups com 1303 SWPRO_800 2200 ENG 3 SW PRO 800VA 2 200VA USER MANUAL o OPERATION e For you to get higher performance of this UPS it is important to understand how it works e This is an interactive UPS and protects your computer related equipments as well as your valuable information When minor power failures occurs electrical surges or sags your UPS quickly regulates voltage by means of its voltage stabilization without using batteries When failure slips out of the UPS regulation range as in a black out UPS inverter starts working to generate power from energy stored in the batteries so you can properly close all applications save your data and close operating system e Under normal conditions your UPS keeps charged and standing by e This unit is equipped with a LED indicator to let you know about UPS status e Power pushbutton is located in UPS front panel To power up your UPS press power pushbutton once during 1 second To power off your UPS press power pushbutton again for 2 to 3 seconds e Cold star
5. ety and performance certifications listed above UPS manufacturer is not responsible of any modification made on the product or its accessories after it is manufactured This product is designed to operate in domestic and commercial environment www integra ups com 1303 SWPRO_800 2200 ENG 5 Le SW PRO 800VA 2 200VA Gas USER MANUAL 10 AFTER SALES SUPPORT amp WARRANTY Support If a failure or problem is detected please check troubleshooting section in user manual If problem cannot be solved please contact authorized service center or authorized dealer Batteries Rechargeable batteries can be charged and discharged hundreds of times However they will eventually wear out This is not a defect or failure so that batteries wear out is not covered by this warranty Battery lifetime will depend of operative conditions like working temperature type and frequency of discharging cycles Higher the temperature shorter will be the lifetime Frequent and deep discharging cycles also will short lifetime For critical applications batteries should be revised and replaced periodically Long storage longer than 6 months without required recharging will wear out batteries This situation is not covered by this limited warranty since this is not considered as a defect Check recharging instructions on user manual Conditions Limited Warranty PLUS 1 Subject to the conditions of this limited warranty this product is warranted to be free from defects i
6. n materials and workmanship at the time of INTEGRA supplies the product In Europe warranty time is 2 years on electronic parts and 2 year on internal batteries from INTEGRA invoice date In America warranty time is 2 years on electronic parts and 1 year on internal batteries from INTEGRA invoice date Standard warranty times could vary depending on country region or extended by purchasing warranty options Please check warranty conditions by country region in our web www integra ups com 2 lf during the warranty period this product fails to operate under normal use and service due to defects in materials or workmanship authorized distributor or service center will at their option either repair or replace the product in accordance with terms and conditions stipulated herein Transportation expenses are not covered by this limited warranty 3 Warranty is valid only if the original invoice issued by INTEGRA specifying date of purchase serial number and name of the dealer is presented with the product to be revised INTEGRA and authorized partners reserve the right to refuse warranty service if any of this information has been removed changed or missing in original invoice document 4 If product is repaired or replaced repaired or replaced product will be warranted for the remaining time of the original warranty or for 90 days on repaired part from date of repair whichever is longer 5 INTEGRA or their distribution service partners reser
7. roper installation Input fuse or breaker reset or replacement is not covered by this warranty 11 This warranty does not cover damages produced during transportation from user to technical service caused by improper packing of the product by user 12 Warranty terms and conditions cannot be modified or extended by third parties without written approval of INTEGRA Limited Warranty PLUS INTEGRA does not warrant that the operation of this product will be uninterrupted or error free during its lifetime If product fails to work the maximum liability of INTEGRA under this limited warranty is expressly limited to the lesser of the price you have paid for the product or the cost of repairing or replacement of any hardware components that malfunction in conditions of normal use In no event will INTEGRA be liable for any damages caused by the product or the failure of the product to perform including any lost profits or savings or special incidental or consequential damages INTEGRA is not liable for any claim made by a third party to INTEGRA or to final user INTEGRA is not responsible for damage that occurs as a result of your failure to follow the instructions intended for this hardware product INTEGRA is not responsible for damage that occurs as a result of your failure to follow the instructions intended for this hardware product www integra ups com 1303 SWPRO_800 2200 ENG 6 hoaa SW PRO 800VA 2 200VA TE USER MANUAL 11 TECHNICAL
8. s manual The manufacturer is not liable for any damage that might rise from misusing this unit or defective installation WARNING Only computer related equipment can be connected to this UPS DO NOT connect medical equipments life support equipments microwave ovens vacuum Cleaners refrigerators or any other appliance to this UPS WARNING UPS must be checked repaired and maintained by qualified personnel only WARNING ELECTRIC SHOCK RISK Inside the UPS there are dangerous high voltages even when disconnected of power line due to internal batteries WARNING In case of emergency turn off the UPS pressing Power Button unplug it and call technical support Disposal We strongly recommend disposing this UPS according to regulations in your country to prevent possible environmental damages besides some parts might be recycled BATTERY WARNING DO NOT dispose batteries in fire as it might explode DO NOT try to open batteries there are dangerous liquids inside 2 APPLICATIONS This is an Interactive sine wave type UPS It is suitable for all kind of PC related applications even those using active PFC power supplies Do not plug this UPS to electrical sources powered by generators Usually electrical generators provide a poor quality power that will force this UPS to work erratically www integra ups com 1303 SWPRO_800 2200 ENG 2 SW PRO 800VA 2 200VA USER MANUAL 3 PRODUCT DESCRIPTION SW PRO 800 1100 1600 2000
9. t function allows you to power up your UPS and your equipments even during power loss thus your UPS acts like a small power generator 6 SOFTWARE Our software offers great features to communicate your PC and UPS allowing an effective management of UPS Capabilities Software Downloading Procedure Go to www integra ups com and select download section Choose the appropriate version of VIEWPOWER according to your Operative System PASSWORD To access as administrator the password to be used is administrator VERY IMPORTANT Download installation and operation manual as well follow all instructions 7 BATTERIES MAINTENANCE Batteries despite its technology are components that lose capacity after some time and usage INTEGRA cares for using first quality batteries in all UPS models Life expectancy may be shortened by some operation conditions With higher temperatures and frequent use batteries tend to lose capacity faster When UPS is stored for long time it is important to recharge its batteries every 3 months If batteries are not recharged they will finally get damage This kind of damage is not a failure so it is not covered by warranty Batteries must be checked periodically to assure the appropriate back up www integra ups com 1303 SWPRO_800 2200 ENG 4 Le SW PRO 800VA 2 200VA Gas USER MANUAL 8 TROUBLESHOOTING Problem Possible Cause Solutions LCD is OFF even UPS is JAC input is not connected well Check if
10. the input power cord is firmly connected to plugged in AC source the mains AC input is connected to the UPS Plug AC input power cord to AC input correctly Battery runtime is shorter Batteries are not fully charged Charge the batteries at least 6 hours and then check the capacity again If the problem persists please consult your dealer Batteries need replacement Contact your dealer to replace the batteries Warning or faulticonis _ Fan is locked or not working Check fans and notify your dealer shown and alarm is The UPS is overload Remove some loads first Before reconnecting continuously sounding devices please verify the total loads match the UPS Capability specified in the spec Low battery icon is shown Low battery Charge the UPS at least 6 hours on the LCD screen 9 QUALITY PERFORMANCE SAFETY SAFETY LOW VOLTAGE DIRECTIVE 2006 95 EC ee UPS Part 1 1 General amp Safety UPS in accessible areas IEC EN 62040 1 ELECTROMAGNETIC COMPATIBILITY EMC DIRECTIVE 2004 108 EC Low Freq Conducted Disturbances amp Signals IEC EN 61000 2 2 IEC EN 61000 4 5 Line to Line Level 2 Surge immunity Line to Earth Level 3 UPS Part 3 Methods of operation specifications and test requirement IEC EN 62040 3 IT Equipments SAFETY Part 1 General Requirements IEC EN 60950 1 QUALITY MANAGEMENT ISO 9001 2000 Any modification made by user or operator may affect compliance of the saf
11. ve the right to charge handling fee if returned product is free of failure or it is out of warranty because any of the reasons described in this warranty 6 If product is out of warranty a reparation proposal will be sent to the user for his approval If proposal is not accepted service center will keep product available for the user during 60 continuous days After this period product would be disposed and user will not be able to rise any claim 7 Rechargeable batteries like included in this product will definitively wear out even under normal operation This is not a defect or failure so it is not covered by this warranty 8 This warranty does not cover batteries wear out caused by improper or long storage over 6 months without required recharging indicated in product manual Even performing recharging procedure this product cannot be storage longer than 18 months Problems on batteries caused by this kind of long storage are not covered by this warranty 9 This warranty does not cover product failures caused by installations modifications or repair performed by non authorized person If product is open by not authorized technician warranty will be considered void This warranty does not cover failure caused by inadequate installation or maintenance misuse accidents fire or floods 10 This product can include protection devices like input fuse or input breaker Activation of this kind of devices is not a failure since it is caused by an imp
Download Pdf Manuals
Related Search
Related Contents
Installation and User`s Manual RAPTAIR60 Diesel Driven EliteBook 8560w Equip Cat.6 Unshielded Keystone Jack Toolfree User Manual XGRIP N08QI Raconter une histoire PEMF Sylvie Ledouxx Frigidaire FAS156P1A 15100 BTU 115V 12.0A 10.7 EER1 BRAND IN STOCK Air Conditioner MPEGIOPro SDK User Manual CanopyTM Subscriber Module USER MANUAL SM02-UG Integrated VIS-NIR Hyperspectral / Thermal-IR Electro Copyright © All rights reserved.