Home

FOS 100 FC - FOS 100 CT User manual rel 4.2 Eng

image

Contents

1. 4 Pin1 RED Pin 2 RED FOS 100 CT ii Pin 4 GREEN Pin 5 BLUE Pin 6 BLUE Pin 7 WHITE Pin 8 WHITE IMPORTANT The maximum number of FOS 100 FC or CT connectable to each Z8 LEDs output is 1 pcs NEVER CONNECT OR DISCONNECT A FOS UNIT WHEN THE POWER SUPPLY IS TURNED ON The maximum distance between the Z8 and the FOS 100 FC or CT should not exceed 50 meters 43 information contained in this publication has been carefully prepared and checked However responsibility will be taken for any errors All rights are reserved and this document cannot be copied photocopied or reproduced in part or completely without prior written consent from D T S D T S reserves the right to make any aesthetic functional or design modifications to any of its products without prior notice D T S assumes no responsibility for the use or application of the products or circuits described herein MADE IN ITALY The Lighting Company ISO 9001 2008 5 quality system is certified to the ISO 9001 2008 standard D T S products are designed and manufactured at the D T S plants in italy 05171075 D T S Illuminazione s r l Via Fagnano 10 12 14 47843 Misano Adriatico RN Italy Tel 39 0541 611131 Fax 39 0541 611111 info dts lighting it www dts lighting it
2. 5 Illuminazione s r l ITALY The Lighting Company ttp www dts lighting it Made in Italy 2 FOS 100 Le informazioni contenute questo documento sono state attentamente redatte e controllate Tuttavia non assunta alcuna responsabilit per eventuali inesattezze Tutti i diritti sono riservati e questo documento non pu essere copiato fotocopiato riprodotto per intero o in parte senza previo consenso scritto della D T S DTS si riserva il diritto di apportare senza preavviso cambiamenti e modifiche estetiche funzionali o di design a ciascun proprio prodotto D T S non assume alcuna responsabilita sull uso o sull applicazione dei prodotti o dei circuiti descritti The information contained in this publication has been carefully prepared and checked However no responsibility will be taken for any errors All rights are reserved and this document cannot be copied photocopied or reproduced in part or completely without prior written consent from D T S D T S reserves the right to make any aesthetic functional or design modifications to any of its products without prior notice D T S assumes no responsibility for the use or application of the products or circuits described herein Les informations contenues dans le pr sent manuel ont t r dig es et contr l es avec le plus grand soin Nous d clinons toutefois toute responsabilit en cas d ventuelles inexactitudes Tous droits r serv s Ce document ne pe
3. UNIT DIMENSIONS gt lt TT Fo r E 1 5A pt Cl 541 WE LO Packing Dimensions LXWXH 1060 x 160 x 200 mm Weight 8 5 KG 7 5 100 SOLO 65 FC 5 100 SOLO IP 65 UNIT DIMENSIONS gt lt TT Fog r E 1 5A Cl 541 WE LO Packing Dimensions LXWXH 1060 x 160 x 200 mm Weight 8 5 KG 8 FOS 100 IMPORTANT SAFETY INFORMATION Fire prevention It is permissible to place the unit on normally flammable surfaces Suitable for mounting on normally flammable materials surfaces greater than 200 C with some combustion time lag Prevention from electric shock High voltage is present inside the unit Unplug the unit prior to performing any operation which involves touching the inside of the unit Do not open the unit The level of technology inherent in the unit requires the assistance of specialised personnel for all servicing Please refer to an authorised D T S service centre This equipment must be grounded do not connect to non grounded supplies The use of a thermal magnetic circuit br
4. 14 FOS 100 DMX SIGNAL CONNECTION FOS 100 SOLO IP 65 FC FOS 100 SOLO IP 65 CT The unit operates using a digital DMX 512 signal Connection between the controller and the unit or between units must be carried out using a two pair screened g 0 5 mm Ensure that the conductors do not touch each other Do not connect the cable ground to the DMX connector chassis The plug housing must be isolated Connect the mixer signal to the DMX IN projector plug and connect it to the next projector by connecting the DMX OUT plug on the first unit to the DMX IN plug of the second one In this way all the projectors are cascade connected CONTROLLER STANDARD DMX 512 2 DATA P S If the display showing the DMX address flashes then one of the following errors has occurred DMX signal not present DMX reception problem For Installations where long distance DMX cable connections are needed we suggest to use a DMX terminator The DMX terminator is a male DMX cable connector with a 120 ohm resistor Between pin 2 and 3 The DMX terminator must be plugged into the DMX out panel connector of the last unit connected to the DMX line DMX MALE CABLE CONNECTOR GND DATA DATA 120 OHM PLACE A 120 OHM RESISTOR BETWEEN PIN 2 AND 3 OF A MALE DMX CONNECTOR AND PLUG IT INTO THE DMX OUT PANEL CONNECTOR OF THE LAST UNIT CONNECTED TO THE DMX LINE 15 5 100 DMX ADDRESS FOS 100 SOLO FC and FOS 100 SOLO CT can be used i
5. 28 FOS 100 DMX range Mode Option Function Value 0255 1 1 colour DMX range Mode Option Function Value 0255 1 colour DMX range Mode Option Function Value 0255 Proportional colour 29 5 100 WALL 6 CHANNELS MODE For use with DTS Wall mounted DMX controller 05141007 IS IS IS IS IR GREEN MENU Up Down ENTER Up Down 1 2 RED 3 BLUE 4 DIMMER 5 NOT USED 6 SHUTTER DMX CHANNEL 1 Parameter GREEN DMX range Mode Option Function Value 025 Proportional colour DMX CHANNEL 2 Parameter RED DMX range Mode Option Function Value 0255 11 Proportional colour Parameter BLUE DMX range Mode Option Function Value Parameter DIMMER DMX range Value DMXCHANNEL 5 Parameter NOT USED DMX range Value DMX CHANNEL 6 Parameter SHUTTER 09 5 poo Black out 1 9 4 0 Black out Strobe at variable speed from slow to fast 3 27 s 30ms 120 149 Pulse open at variable speed from slow to fast 42 6 s 120ms 150 3179 Pulse close at variable speed from slow to fast 42 6 s 120ms 180 204 192 Random Strobe Master and RGBW active 205 229 218 Random Strobe Full 230 234 Red Yellow Cyan and Blue colour effects at variable speed 235 255 245 Open DMX range Value 3
6. 5 100 DMX SIGNAL CONNECTION FOS 100 SOLO IP 20 FC FOS 100 SOLO IP 20 CT The unit operates using a digital DMX 512 signal Connection between the controller and the unit or between units must be carried out using a two pair screened 0 0 5 mm Ensure that the conductors do not touch each other Do not connect the cable ground to the DMX connector chassis The plug housing must be isolated Connect the mixer signal to DMX IN projector plug and connect it to the next projector by connecting the DMX OUT plug on the first unit to the DMX IN plug of the second one In this way all the projectors are cascade connected CONTROLLER STANDARD DMX 512 m Pa 1 GND 2 DATA 4 S 2 3 DATA 3 P S If the display showing the DMX address flashes then one of the following errors has occurred DMX signal not present DMX reception problem For Installations where long distance DMX cable connections are needed we suggest to use a DMX terminator The DMX terminator is a male XLR 3 5 pins connector with a 120 ohm resistor Between pin 2 and 3 The DMX terminator must be plugged into the last unit DMX out panel connector of the DMX line PLACE A 120 OHM RESISTOR BETWEEN PIN 2 AND 3 OF A MALE XRL CONNECTOR AND PLUG IT INTO THE DMX OUT PANEL CONNECTOR OF THE LAST UNIT CONNECTED TO THE DMX LINE PIN 3 PIN 2 The standard configuration of the FOS 100 SOLO is with XLR 5 pins connectors
7. Er RUEC MENU Up Down ENTER Down AUTOMATIC MODE Automatic demo game without DMX controller ChPr Chase with 16 steps previously created in REC MODE Speed and Wait time selectable by user CUPr RGB values selectable by user Rainbow rAIn Rainbow colours effect Speed time selectable by user CU01 CU16 Color Macros as on DMX channel 8 Macro WHITE MACROS 16 macros for White color from 2700K to 8000K FOS 100 FC or 2700K to 6500K FOS 100 CT DIMMER Dimmer level selectable by user as on DMX channel 2 Dimmer Dimmer level is active for all the programs and macros SHUTTER Shutter level selectable by user as on DMX channel 1 Shutter Shutter level is active only for CU01 CU16 and Wh01 Wh16 macros ESC Esc from Automatic Mode Menu REC MODE In DMX Recorder Mode it is possible to create and store the scenes of the ChPr by using an external DMX controller The unit must be set to 10 channels MODE IS Down 00 iis ES Down ES Up A DU ifs ENTER Up Down ENTER ENTER Up Down ENTER IS Up LN Up Down 19 5 100 DMX Recorder Mode For the programming of ChPr by using a DMX controller besides the 10 channels necessary to control the unit a further 3 DMX channels are needed So that in RECORDER mode via the unit will need 13 channels to be correctly program
8. Function at 3044 4559 Mater 0 6074 1 7589 Macros 2 90100 X ___ ____ 10519 17 ____ 120 14 ____ 135449 7 ____ 150 164 Marol 1653179 1 1814 2 2 195200 2025 1 14 ____ 2629 17 Mars 240255 1 Macrot 6 O 5 100 2 DMX CHANNEL 9 Parameter COLOUR MACROS IF FS JE SS HIS PLEASE CHECK PAGE 13 Move degrees 1522 12111212 2330 1711 Maro2 3138 1211212 Macrod 3946 171212 4 ____ _ 4754 Macros O 22112122 Maro 6370 723278 12114212 2 79 86 ____ 8794 Macro 10 ____ 95300 Macro 2 172 2 mas O Mar O Cusa _ ____ o 20 127 134 111 15 00000 135 1432 117112 16 143450 17 Rainbow Speed 1 1 Sec 151058 171 RainbowSpeed2 58ec 159466 Rainbow Speed 3 10 Sec 16 174 171 Rainbow Speed 4 20 Sec 17551822 Rainbow Speed 5 30 Sec 183 190 Rainbow Speed 6 60 Sec Rainbow Speed 7 120 Sec 199206 171 Rainbow Speed 8 180 Sec
9. Speed time and Wait time on the Master have priority on the slave units NB It is possible to run GA Pr on the other units even though these do not have GA Pr programmed You can do this by setting the units to 10 DMX channels mode and selecting DMX address A001 22 FOS 100 Rec mode It is possible to program your own game on the FOS 100 SOLO FULL RGBW FOS 100 SOLO FULL WHITE CT that will then run it in AUTO mode ChPr Each unit can have its own programmed game In REC mode the unit must be set to 10 DMX channels mode To program the ChPr by using a DMX controller you need 3 more channels in addition to the 10 channels necessary to control the unit So that in RECORDER mode via DMX the unit will need 12 13 DMX channels to be correctly programmed The three new DMX channels are DMX channel 11 SCENES channel From 0 10 no function r001 From 11 255 are displayed the programmable scenes max 16 scenes from M001 to M0016 DMX channel 12 EDIT channel From 0 19 no function From 20 234 the unit runs the configuration given by the received input DMX values With the channel SCENES it is possible to pass from one step to the next while with REC it is possible to record the selected scene From 235 255 the unit runs the configuration given by the received input DMX values closing the sequence as last scene With the channel REC it is possible to record the selected scene as last scene DMX channel 13 RECORDING ch
10. _ ____ Random Speed 1 0 5 sec 21822 Random Speed 2 1 Sec 223230 771 3 2 Sec 3238 RandemSpeed SSe 239246 Random Speed 5 10 Sec 247 288 Random Speed 6 30 Sec Parameter FUNCTIONS Recall Create and Store the Custom white BENI Move DD rangs range Mode Option Function Value degrees O gt gt 10 79 Custom White Recall Enable 7 for Custom white Recall 80 160 Custom White Create Enable 7 for Custom white Creation 161 255 Custom White Store Store the Custom White created 27 5 100 DMX PROTOCOL FOS 100 SOLO FC 6 CHANNELS MODE Shutter Dimmer RGBW SHUTTER DIMMER RED GREEN BLUE WHITE 1 Parameter SHUTTER DMX range Mode Option Function Value Black out 25 1 8 1 Open 32029 24 Black out 30 119 Strobe at variable speed from slow to fast 3 27 s 30ms 120 149 Pulse open at variable speed from slow to fast 42 6 s 120ms 150 179 Pulse close at variable speed from slow to fast 42 6 s 120ms 180 204 192 Random Strobe Master and RGBW active 205 229 218 Random Strobe Full 230 234 Red Yellow Cyan and Blue colour effects at variable speed 235 255 245 Open DMX CHANNEL Parameter DIMMER DMX range Value DMX range Value 0255 1 1 colour
11. 1 RED WHITE 1 2 RED WHITE 1 3 GREEN WHITE 2 4 GREEN WHITE 2 5 BLUE WHITE 3 6 BLUE WHITE 3 7 WHITE WHITE 4 8 WHITE WHITE 4 10 FOS 100 CONNECTIONS FOS 100 SOLO IP 65 FC FOS 100 SOLO IP 65 CT GND GND DATA DATA MAINS INPUT DATA DATA 90 260 Vac 50 60 Hz Power cable with cable gland ILME 4 poles female 9 DMX OUT panel connector ILME 4 poles female panel connector MAINS OUTPUT 90 260Vac 50 60 Hz ILME 5 poles panel connector MAX Load Li 230 Vac 20 FOS 100 SOLO 2 110 Vac 10 FOS 100 SOLO Se LED INPUT LED OUTPUT M12 Male cable connector M12 Female panel connector LEDs Connector PinOut 1 RED WHITE 1 2 RED WHITE 1 3 WHITE 2 4 GREEN WHITE 2 5 BLUE WHITE 3 6 BLUE WHITE 3 7 WHITE WHITE 4 8 WHITE WHITE 4 11 FOS 100 INPUT OUTPUT CONNECTIONS FOS 100 FC FOS 100 CT LED INPUT LEDs Connector PinOut M12 Male cable connector 1 RED WHITE 1 2 RED WHITE 1 3 GREEN WHITE 2 4 GREEN WHITE 2 5 BLUE WHITE 3 6 BLUE WHITE 3 T WHITE WHITE 4 8 WHITE WHITE 4 12 INSTALLATION The unit is suitable for use in wet locations The unit may be either floor or ceiling mounted FLOOR MOUNTING INSTALLATION CEILING MOUNTING INSTALLATION Ss gt STANDARD SHORT BRACKET 13
12. Macro 2 172 2 mas O Mar O Cusa _ ____ o 20 127 134 111 15 00000 135 1432 117112 16 143450 17 Rainbow Speed 1 1 Sec 151058 171 RainbowSpeed2 58ec 159466 Rainbow Speed 3 10 Sec 16 174 171 Rainbow Speed 4 20 Sec 17551822 Rainbow Speed 5 30 Sec 183 190 Rainbow Speed 6 60 Sec Rainbow Speed 7 120 Sec 199206 171 Rainbow Speed 8 180 Sec _ ____ Random Speed 1 0 5 sec 21822 Random Speed 2 1 Sec 223230 771 3 2 Sec 3238 RandemSpeed SSe 239246 Random Speed 5 10 Sec 247 288 Random Speed 6 30 Sec Parameter FUNCTIONS Recall Create and Store the Custom white BENI Move DD rangs range Mode Option Function Value degrees O gt gt 10 79 Custom White Recall Enable 7 for Custom white Recall 80 160 Custom White Create Enable 7 for Custom white Creation 161 255 Custom White Store Store the Custom White created 36 5 100 DMX PROT L FOS 100 SOLO CT 6 CHANNELS MODE Shutter Dimmer RGBW SHUTTER DIMMER RED WHITE 1 GREEN WHITE 2 BLUE WHITE 3 WHITE WHITE 4 1 Parameter SHUTTER DMX range Mode Option Function Value Black out 25 1 8 1 Open 32
13. 09255 11 Proportional colour 1 CHANNEL MODE 1 DIMMER DMX CHANNEL Parameter DIMMER DMX range Value 41 5 100 WIRING CONNECTIONS FOS 100 FC LED INPUT Pin1 RED M12 Male cable connector Pin 2 RED Pin GREEN Pin 4 GREEN Pin 5 BLUE Pin 7 WHITE 21 PLUS IP 20 LED Controller Pin 8 WHITE D T S Code 03 LA 009P ia RJ45 MALE TO M12 FEMALE CABLE CONVERTER D T S Code 03 LA 061 LEDS CONNECTOR PINOUT Pin 1 RED Pin 2 RED Pin 3 GREEN Pin 4 GREEN Pin 5 BLUE Pin 6 BLUE 8 pin Female RJ45 Pin 7 WHITE Pin 8 WHITE IMPORTANT The maximum number of FOS 100 FC or CT connectable to the Z1 PLUS IP20 LED Controller is 1 pcs NEVER CONNECT OR DISCONNECT A FOS 100 UNIT WHEN THE POWER SUPPLY IS TURNED ON The maximum distance between Z1 PLUS power supply and the unit should not exceed 100 meters 42 FOS 100 WIRING CONNECTIONS FOS 100 FC as 4 2 8 33 CORO Cae ULL oN Pint 1 FOS 100 al PIN CONNECTOR MALE ON BOARD FOS 100 Z8 LED Controller M12 outputs T S Code 03 LA 075 V2 PR qm am LEDs OUT 8 np INA SEN LEDs OUT 7 CCP o E CTO A LEDs OUT 6 _ LL ata LEDs OUT 5 gt i PI LEDS CONNECTOR PINOUT M12
14. in automatic mode without a DMX controller First of all connect the projectors with a DMX cable picture below A maximum quantity of 32 slave units can be connected to the same Master unit MASTER SLAVE 32 To activate Auto mode on the first unit use the menu to run through the different modes until AUTO appears on the display and press enter Now it is possible to choose between the different pre programmed games CUPr RAIn CU01 CU16 Wh01 Wh16 or ChPr which is user programmable through REC mode To confirm game activation press ENTER on the selected GAME CUPr RAIn CUO1 CU16 Wh01 Wh16 The first unit that will work as a Master should be placed in Automatic mode AUTO the other units have to be placed in 10 DMX channels mode MODE 10CH and the DMX address should be set at A001 For RaIn rainbow game it is possible to select the speed for the colour changhing SPEE DIMMER function in AUTOMATIC MODE is active for all the programs SHUTTER function in AUTOMATIC MODE is active only for CU01 CU16 and Wh01 Wh16 macros ChPr MASTER SLAVE The first unit that will function as a Master must be set to Automatic mode AUTO the other units must be set to Slave mode SLAV selectable through the menu In this way all the Slave units will be synchronised with the master and running their own ChPr game On the master unit it is possible to vary the Speed time SPEE for the colour changhing and the Wait time UAIt between the steps
15. 0 5 100 DMX PROTOCOL FOS 100 SOLO FC M4CH mode 5 DMX channels Dimmer RGBW DIMMER RED GREEN BLUE WHITE Ul A WN Ez DMX CHANNEL Parameter DIMMER DMX range Value DMX range Value DMX range Value DMX range Value DMX CHANNEL xoia MN Parameter WHITE DMX range Value 6511 Proportional colour 31 5 100 DMX PROTOCOL FOS 100 SOLO FC RGBW mode 4 DMX channels 1 RED 2 GREEN 3 BLUE 4 WHITE Memo 3 Mode Option Function Value __02 1 colour DMX range Mode Option Function Value 5851 Proportional colour range Option Function Value 65511 Proportional colour Value 09255 110101 Proportional colour 1 CHANNEL MODE 1 DIMMER DMX CHANNEL Parameter DIMMER DMX range Value 32 FOS 100 DMX PROT L FOS 100 SOLO CT 10 CHANNELS MODE Default SHUTTER DIMMER RED WHITE 1 GREEN WHITE 2 BLUE WHITE 3 WHITE WHITE 4 WHITE PRE PROGRAMMED CTC COLOURS MACRO FUNCTIONS eOuaoNounBuN pl Parameter SHUTTER Move DID mes range Mode Option Function Value grees Black out 2029 24 Black out 30 119 Strobe at variable speed from slow to fast 3 27 s 30 ms 120 149 Pulse open at variable speed from slow to fast 42 6 s 120ms 150 179 Pulse close at variable speed from slow t
16. 029 24 Black out 30 119 Strobe at variable speed from slow to fast 3 27 s 30ms 120 149 Pulse open at variable speed from slow to fast 42 6 s 120ms 150 179 Pulse close at variable speed from slow to fast 42 6 s 120ms 180 204 192 Random Strobe Master and RGBA active 205 229 218 Random Strobe Full 230 234 Red Yellow Cyan and Blue colour effects at variable speed 235 255 245 Open DMX CHANNEL Parameter DIMMER DMX range Value DMX range Value 0255 1 1 colour 37 FOS 100 BE a Mode Option Function Value 0255 1 colour Parameter BLUE WHITE 3 DMX range Mode Option Function Value 0255 colour DMXCHANNEL 6 Parameter WHITE WHITE 4 Value 0255 1 11 Proportional colour 38 5 100 WALL 6 CHANNELS MODE For use with DTS Wall mounted DMX controller 05141007 IS IS IS IS IR GREEN MENU Up Down ENTER Up Down 1 2 RED 3 BLUE 4 DIMMER 5 NOT USED 6 SHUTTER DMX CHANNEL 1 Parameter GREEN DMX range Mode Option Function Value 025 Proportional colour DMX CHANNEL 2 Parameter RED DMX range Mode Option Function Value 0255 11 Proportional colour Parameter BLUE DMX range Mode Option Function Value Parameter DIMMER DMX range Value DMXCHANNEL 5 Parameter NOT USED D
17. 55 m m RGBA MAXIMUM VALUES This menu allow to select the maximum levels for Red Green IS Down Default 0 9 m A m Blue and White Up Down These settings have priority Default 255 on Master Dimmer channel Default 0 RRP SMOOTH VALUE Up Down i I This menu allow to select the value of the delay in milliseconds for RGBW and Dimmer channels reaction to DMX or Program variation Off 25 ms delay Fast response 20 250 ms delay Slow response Default 255 m A m Range Off 20 IS Default 4 ENTER COMPRESSION Up Down IS LEA Down This menu allow to select between Linear current output or Quadratic current output for LEDs Default Linear Off 25 ms Istant responce to DMX variation 20 250 ms SYNC Smooth response to DMX variation This menu allow to adjust the PWM frequency value Hz in order to reduce flickering in the process of your camera recordings IS IS IS Up Down ENTER Up Down Linear Linear current output ENTER BOOST DRIVING Quadratic This menu allow to increase the LED s Linear light ENTER current from 350 mA to 500 mA output Range 610 Hz 10 KHz Default 610 Hz ENTER Up Down ENTER Up Down 4 Up Down Up Down Boost mode activated IS ENTER Boost mode deactivated With BOOST active the LED s current is set to 500 mA 30 more gain Default Disabled 18 5 100
18. MX range Value DMX CHANNEL 6 Parameter SHUTTER 09 5 poo Black out 1 9 4 0 Black out Strobe at variable speed from slow to fast 3 27 s 30ms 120 149 Pulse open at variable speed from slow to fast 42 6 s 120ms 150 3179 Pulse close at variable speed from slow to fast 42 6 s 120ms 180 204 192 Random Strobe Master and RGBW active 205 229 218 Random Strobe Full 230 234 Red Yellow Cyan and Blue colour effects at variable speed 235 255 245 Open DMX range Value 39 5 100 DMX PROT L FOS 100 SOLO CT M4CH mode 5 DMX channels Dimmer RGBW DIMMER RED WHITE 1 GREEN WHITE 2 BLUE WHITE 3 WHITE WHITE 4 Ul A WN Ez DMX CHANNEL Parameter DIMMER DMX range Value DMX range Value DMX range Value DMX range Value Parameter WHITE WHITE 4 DMX range Value 6511 Proportional colour 40 FOS 100 DMX PROT L FOS 100 SOLO CT RGBW mode 4 DMX channels 1 RED WHITE 1 2 GREEN WHITE 2 3 BLUE WHITE 3 4 WHITE WHITE 4 DMX CHANNEL Parameter RED WHITE 1 Mode Option Function Value __02 1 colour DMX range Mode Option Function Value 551 Proportional colour Parameter BLUE WHITE 3 DMX range Mode Option Function Value 651 colour meco MN Parameter WHITE WHITE 4 DMX range Mode Option Function Value
19. UE range range Mode Option Function Value 020 255 0 6 Proportionalcolour DMX CHANNEL es Parameter WHITE Move range Mode Option Function Value 0 255 Proportionalcolour Parameter WHITE PRE PROGRAMMED DMX range Mode Option Function Value 485 No Function 56 105 Full Red Green Blue White at Full 106 155 130 White DTS IF CHANNEL 10 FUNCTIONS CUSTOM WHITE RECALL Dmx range value 0 79 156 205 180 Custom White Recall 206 255 225 White CTC Channel 8 CTC enabled 256 color temp Correction Macros 2700 8000K IF CHANNEL 10 FUNCTIONS CUSTOM WHITE CREATE Dmx range value 80 160 156 205 Custom White Create RGBW levels selectable by DMX 206 255 White CTC Channel 8 CTC enabled 256 color temp Correction Macros 2700K 8000K 25 FOS 100 _DMX CHANNEL 8 Parameter CTC Color temperature correction Move range Mode Option Function Value degrees IF CHANNEL 7 White WHITE CTC Dmx range value 206 255 0 255 256 color temp Correction Macros 0 2700K 128 5500K 255 8000K IF CHANNEL 7 White NO FUNCTION Dmx range value 0 43 0 255 No Function DMX CHANNEL 9 Parameter COLOUR MACROS IF E I oe E St GIE PLEASE CHECK PAGE 13 Move DMX range range Mode Option Function Value 09344 14 No Function
20. annel Records the set scene with a variation between 0 to 255 the display flashes indicating that the scene has been recorded It is advised that you keep the REC channel set to 0 and to run through the 255 only once you have decided to save the scene If ChPr is not closed by indicating the last scene Edit channel between 235 255 in playback mode all 16 scenes will be played through even if not programmed 23 FOS 100 DMX PROTOCOL FOS 100 SOLO FC 10 CHANNELS MODE Default SHUTTER DIMMER RED GREEN BLUE WHITE WHITE PRE PROGRAMMED CTC COLOURS MACRO FUNCTIONS NN AU RW pl E Parameter SHUTTER Move DAMA range Mode Option Function Value grees Black out 20 29 24 Black out 30 119 Strobe at variable speed from slow to fast 3 27 s 30 ms 120 149 Pulse open at variable speed from slow to fast 42 6 s 120ms 150 179 Pulse close at variable speed from slow to fast 42 6 s 12015 180 204 192 Random Strobe Master and RGBA active 205 229 218 Random Strobe Full 230 234 Red Yellow Cyan and Blue colour effects at variable speed 235 255 245 DMX CHANNEL Parameter DIMMER DMX range Value DMX range Value 551 Proportional colour 24 5 100 DMX CHANNEL E Parameter GREEN EEE Move DID renge range Mode Option Function Value 0 255 Proportionalcolour DMX CHANNEL Parameter BL
21. eaker is recommended for each unit Use only AC supplies 90 260V 50 60Hz The unit should never be located in position exposed to rain or in areas of extreme humidity A good air ventilation is essential for proper equipment work Safety The unit is not for residential use and must be installed by a qualified electrician or experienced person In case lenses sets replacement is needed frontal gasket must be replaced so as to maintain 65 rate protection LEDs are not replaceable The external surface of the unit may exeed 50 C never handle the unit until at least 5 minutes have elapsed since the unit was turned off Never install the unit in an enclosed area lacking sufficient air flow The ambient temperature should not exeed 40 C and should not be lower than 10 C CONNECTIONS FOS 100 SOLO IP 20 FC FOS 100 SOLO IP 20 CT LED OUTPUT M12 Female panel connector 9 FOS 100 DMX IN OUT XLR 5 poles Male Female panel connectors DMX 512 oun wing Mas n 20 as PA me TT DON 10 MAINS OUT 3 T um MAINS INPUT MAINS OUTPUT 90 260Vac 50 60 Hz 90 260 Vac 50 60 Hz POWERCON panel connector POWERCON panel connector MAX Load 230 Vac 20 FOS 100 SOLO 110 Vac 10 FOS 100 SOLO LED INPUT LED OUTPUT M12 Male cable connector M12 Female panel connector LEDs Connector PinOut
22. es Black finish LED technology FOS 100 FC 15 x FULL RGBW LEDs 4608 Lumens 16 million colours colour temperature range 2700 8000K FOS 100 CT 15 x FULL WHITE LEDs 6720 Lumens 16 million colours colour temperature range 2700 6500 LEDs average lifespan 75 000 hours 70 lumen output Optical units 3 lenses sets available Spot Medium flood and Wide flood Control Via any DMX lighting console External Power supply LED Controller is needed Protection IP 65 protection level Construction Extruded aluminium Power supply Electronic full range 90 260Vac 50 60 Hz 21 PLUS IP 20 LED Controller D T S Code 03 LA 009P 21 PLUS IP 65 LED Controller D T S Code 03 LA 009P IP65 28 LED Controller M12 outputs D T S Code 03 LA 075 V2 28 LED Controller Screw terminals outputs D T S Code 03 LA 080 V2 DRIVENET 832 LED Controller Screw terminals outputs D T S Code 03 LA 177 Power consumption 100W Max Connection Cable with M12 male connector Weight 5 5 Kg 5 100 5 100 UNIT DIMENSIONS Packing Dimensions LxWxH 1060 x 160 x 200 mm Weight 7 Kg 5 FOS 100 FOS 100 SOLO FC FOS 100 SOLO CT D T S Product codes 03 LBB014S11FC10 FOS 100 SOLO IP 20 FC Narrow lenses Black finish 03 LBB014S11FC25 FOS 100 SOLO IP 20 FC Medium flood lenses Black finish 03 LBB014S11FC40 FOS 100 SOLO IP 20 FC Wide flood lenses Black finish 03 LBBO10S11FC10 FOS 100 SOLO IP 65 FC Narrow len
23. ght the unit functions by using the D T S infrared remote control D T S Code 0514L008 WIRELESS DMX Wireless DMX enabled disabled NOT IMPLEMENTED ON FOS 100 IS WIRELESS DMX Disabled ENTER Default WIRELESS DMX Enabled 353 UNLINK LOG OUT ENTER Wireless DMX receiver kit on FOS 100 is available on request Up Down FAN SPEED MIL Internal Fan Speed control selectable by user Range OFF 24 volt Default 12 volt ENTER Fan Speed Control Range OFF 24 volt Default 12 volt 8 ENTER Up Down LME _ MENU Up Down Loe 1 ENTER Up Down EMERGENCY Emergency operating mode By setting Emergency mode it will be possible to select one of the 16 preprogrammed WHITE cues that will then ran if DMX signal is missing or not available Usefull for Emergency EXIT ilumination on public areas ENTER Default OFF Default White 1 Default 255 8 8 N 0 FOS 100 MENU Up Down ENTER ENTER DEFAULT To restore default settings Leng Internal Unit temperature MENU Up Down III ENTER Lik 3L ENTER Celsius TEMPERATURE Internal Unit temperature visualisation LIFE TIME This menu show the total UNIT life time and the RGBW life time uam MENU Up Down ENTER TEST MODE RGBW colours test with rainbow MENU Up Down SOFTWARE Software version 21 5 100 AUTOMATIC OPERATION AUTO FOS 100 SOLO can work
24. ls mode Shutter Dimmer RGBW 15 DMX 15 CHANNELS channels mode WALL mode 6 DMX i channels for use with DTS Wall IS mounted DMX controller 05141007 mode 5 DMX channels Dimmer VALLI RGBW RGBW mode 4 channels 1 DMX channel mode Eg 5 CHANNELS ON OFF control on IR connector IS L Cl ncbA 4CHANNELS not implemented on FOS 100 SOLO ENTER RS Default DMX Mode 10 CH Shutter Dimmer RGBW IS IS IS DS Dimmer RGBW Custom mode enabled Lt Shot LI Show Custom settings SEL IS Parameters Setting on ES Custom Mode 17 FOS 100 IS IS IF 111111 3 External ON OFF control on IR MENU Up Down ENTER Up Down PA ENTER connector not implemented on FOS 100 SOLO Standard mode enabled ES Down Defau It MACRO Function enable channel i Hi x Up Down mapping macro rainbow effects STD default 248198 mode enabled 55 Rainbow effects on MACRO ENTER channel IS IS gt Default 0 MENU Up Down ENTER Up Down ES 0 Down ENTER LED RGBW Min Max Smooth Compression Default 255 IS Sync and Boost level values settings RGBA MINIMUM VALUES Default 0 This menu allow to select the Up Down minimum levels for Red Green Blue and White ES Down 8 8 Default 2
25. med The three new DMX channels are DMX channel 11 SCENES channel From 0 10 no function r001 From 11 255 are displayed the programmable scenes max 16 scenes from M001 to M0016 DMX channel 12 EDIT channel From 0 19 no function From 20 234 the unit runs the configuration given by the received input DMX values With the channel SCENES it is possible to pass from one step to the next while with REC it is possible to record the selected scene From 235 255 the unit runs the configuration given by the received input DMX values closing the sequence as last scene With the channel REC it is possible to record the selected scene as last scene channel 13 RECORDING channel Records the set scene with a variation between 0 to 255 the display flashes indicating that the scene has been recorded It is advised that you keep the REC channel set to 0 and to run through the 255 only once you have decided to save the scene If ChPr is not closed by indicating the last scene Edit channel between 235 255 in playback mode all 16 scenes will be played through even if not programmed IS US Down SL AUS SUPE ES Up Down ais n ENTER Slave mode for ChPr program All slave units will be synchronised with master unit running their own Chpr program ENTER NOTE INFRARED MODE External infrared remote sensor Infrared remote control needed By activating Ir MODE it will be D T S Code 03 LA 016 possible to navigate trou
26. n seven different modes 10 DMX channels mode default 6 DMX channels mode Shutter Dimmer RGBW WALL mode 6 DMX channels for use with DTS Wall mounted DMX controller 0514L007 M4CH mode 5 DMX channels Dimmer RGBW RGBW mode 4 channels 1 DMX channel mode or CUSTOM DMX mode not yet implemented If you want to use the FOS 100 SOLO FC or CT in WALL mode select the WALL mode from the MODE menu and set the following addresses on the mixer To be used only with DTS Wall mounted DMX controller 0514L007 Projector 1 001 Projector 2 A006 If you want to select the next projector just add 6 Projector 3 012 DTS Wall mounted DMX controller 0514L007 assign 6 DMX o A channels per unit also if some channels are not used projector 6 030 If you want to use the FOS 100 SOLO FC or CT in 10 channels mode select the 10 CH mode from the MODE menu and set the following addresses on the mixer Projector 1 001 Projector 2 011 If you want to select the next projector just add 10 Projector 3 A021 projector 6 051 Selecting the DMX address 1 Press the UP DOWN key until you reach the required DMX address The numbers on the display will start to flash but the new DMX address hasn t yet been set 2 Press ENTER to confirm your selection The numbers on the display will stop flashing and the projector is now controlled by the new DMX address TIPS if you keep pushed the UP or DOWN keys
27. o fast 42 6 s 1205 180 204 192 Random Strobe Master and RGBW active 205 229 218 Random Strobe Full 230 234 Red Yellow Cyan and Blue colour effects at variable speed 235 255 245 DMX CHANNEL Parameter DIMMER Move DAMA renge range Mode Option Function Value 0 255 Proportional dimmer Move DAMA range range Mode Option Function Value grees 0 255 Proportionalcolour 33 5 100 DMX range Mode Option Function Value 0255 Proportional colour Parameter BLUE WHITE 3 DMX range Mode Option Function Value 0255 1 Proportional colour DMX CHANNEL 6 Parameter WHITE WHITE 4 DMX range Mode Option Function Value 0255 Proportional colour Parameter WHITE PRE PROGRAMMED DMX range Value 485 23 No Function 56 105 80 Full Red Green Blue White at Full 106 155 130 White DTS IF CHANNEL 10 FUNCTIONS CUSTOM WHITE RECALL Dmx range value 0 79 156 205 180 Custom White Recall 206 255 225 White CTC Channel 8 CTC enabled 256 color temp Correction Macros 2700K 6500K IF CHANNEL 10 FUNCTIONS CUSTOM WHITE CREATE Dmx range value 80 160 156 205 Custom White Create RGBW levels selectable by DMX 206 255 White CTC Channel 8 CTC enabled 256 color temp Correction Macros 2700K 6500K 34 FOS 100 _DMX CHANNEL 8 Parameter CTC Color temperature cor
28. rection Move range Mode Option Function Value degrees IF CHANNEL 7 White WHITE CTC Dmx range value 206 255 0 255 256 color temp Correction Macros 0 2700K 128 4500 255 6500 IF CHANNEL 7 White NO FUNCTION Dmx range value 0 43 0 255 No Function DMX CHANNEL 9 Parameter COLOUR MACROS IF E I oe E St GIE PLEASE CHECK PAGE 13 Move DMX range range Mode Option Function Value 09344 14 No Function Function at 3044 4559 Mater 0 6074 1 7589 Macros 2 90100 X ___ ____ 10519 17 ____ 120 14 ____ 135449 7 ____ 150 164 Marol 1653179 1 1814 2 2 195200 2025 1 14 ____ 2629 17 Mars 240255 1 Macrot 6 O 5 100 3 Ul DMX CHANNEL 9 Parameter COLOUR MACROS IF FS JE SS HIS PLEASE CHECK PAGE 13 Move degrees 1522 12111212 2330 1711 Maro2 3138 1211212 Macrod 3946 171212 4 ____ _ 4754 Macros O 22112122 Maro 6370 723278 12114212 2 79 86 ____ 8794 Macro 10 ____ 95300
29. ses Black finish 03 LBBO10S11FC25 FOS 100 SOLO IP 65 FC Medium flood lenses Black finish 03 LBB010S11FC40 FOS 100 SOLO IP 65 FC Wide flood lenses Black finish 03 LBBO14S11FB10 FOS 100 SOLO IP 20 CT Narrow lenses Black finish 03 LBB014S11FB25 FOS 100 SOLO IP 20 CT Medium flood lenses Black finish 03 LBB014S11FB40 FOS 100 SOLO IP 20 CT Wide flood lenses Black finish 03 LBBO10S11FB10 FOS 100 SOLO IP 65 CT Narrow lenses Black finish 03 LBBO10S11FB25 FOS 100 SOLO IP 65 CT Medium flood lenses Black finish 03 LBB010S11FB40 FOS 100 SOLO IP 65 CT Wide flood lenses Black finish LED technology FOS 100 SOLO FC 15 x FULL RGBW LEDs 4608 Lumens 16 million colours colour temperature range 2700 8000K FOS 100 SOLO CT 15 x FULL WHITE LEDs 6720 Lumens 16 million colours colour temperature range 2700 6500 LEDs average lifespan 75 000 hours 70 lumen output Optical units 3 lenses sets available Spot Medium flood and Wide flood Control Via any DMX lighting console Protection IP 20 or IP 65 protection level Construction Extruded aluminium Power supply Integrated Z10 IP 20 or IP 65 Power supply LED Controller Electronic full range 90 260Vac 50 60 Hz Power consumption 100W Max Connection FOS 100 SOLO IP 20 POWERCON In Out XLR 5 poles In Out FOS 100 SOLO IP 65 Power input cable with cable gland HARTING power re send panel connector HARTING DMX 4 poles In Out Weight 7 Kg 6 5 100 SOLO IP 20 FC FOS 100 SOLO IP 20
30. the channels are calculated more quickly and you get a faster selection 16 DISPLAY FUNCTIONS rm EA A Function Panel FOS 100 SOLO FC FOS 100 SOLO CT DISPLAY FUNCTIONS FOS 100 The FOS 100 SOLO display panel shows all the available functions Using these functions it is possible to change some of the parameters and add some functions Changing the D T S setting can vary the functions of the unit so that it does not respond to the DMX 512 signal used to control it Carefully follow the instructions below before carrying out any variations or selections NOTE the symbol m shows which key has to be pushed to obtain the desired function Software version 5 16 MENU Up Down Down REVERSE DISPLAY Reverses display s reading depending on ES Down the mounting position On the ground or suspended DISPLAY STAND BY IS La Down To turn off the display after 5 seconds or leave it always on Floor position Lion IS IS position Display always ON ENTER m Up Down ENTER Up Down 10 CHANNELS DMX MODE AUX mode let you activate an external CUSTOM DMX mode let you set the parameters for Shutter Dimmer Red Green Blue White White pre programmed CTC Macro and Function to the desired DMX channels 1 CHANNEL c 3 ES ES Down To select DMX mode 10 DMX channels mode default 6 DMX channe
31. ut tre copi photocopi ou reproduit dans sa totalit ou partiellement sans le consentement pr alable de D T S D T S se r serve le droit d apporter toutes modifications et am liorations esth tiques fonctionnelles ou de design sans pr avis chacun de ses produits D T S d cline toute responsabilit sur l utilisation ou sur l application des produits ou des circuits d crits Las informaciones contenidas en este documento han sido cuidadosamenteredactadas y controladas Con todo no se asume ninguna responsabilidad por eventuales inexactitudes Todos los derechos han sido reservados y este documento no puede ser copiado fotocopiado o reproducido total o parcialmente sin previa autorizaci nescrita de D T S D T S se reserva el derecho a aportar sin previo aviso cambios y modificaciones de car cter est tico funcional o de diseno a cada producto suyo D T S no se asume responsabilidad de ningun tipo sobre la utilizaci n o sobre la aplicaci n de los productos o de los circuitos descritos 3 FOS 100 5 100 5 100 D T S Product codes O3 LBBO10E11FC10 FOS 100 IP 65 FC Narrow lenses Black finish 03 LBB010E11FC25 FOS 100 IP 65 FC Medium flood lenses Black finish 03 LBB010E11FC40 FOS 100 IP 65 FC Wide flood lenses Black finish 03 LBB010E11FB10 FOS 100 IP 65 CT Narrow lenses Black finish 03 LBB010E11FB25 FOS 100 IP 65 CT Medium flood lenses Black finish 03 LBB010E11FB40 FOS 100 IP 65 CT Wide flood lens