USER MANUAL REMOTE CONTROL RCW10

image

Contents

1. Off state after power failure and then power recovery Memory recovery If this function has been set for the wired controller the wired controller after power failure will resume its original running state upon power recovery Memory contents On Off Mode set temperature set fan speed and Lock function 4 Installation and Dismantlement 4 1 Connection of the Signal Line of the Wired Controller e Open the cover of the electric control box of the indoor unit e Let the single line of the wired controller through the rubber ring e Connect the signal line of the wired control to the 4 pin socket of the indoor unit PCB e Tighten the signal wire with ties e The communication distance between the main board and the wired controller can be up to 20 meters the standard distance is 8 meters 4 2 Installation of the Wired Controller PVC Pipe iz Y Fig 4 1 Accessories for the Installation of the Wired Controller Table 4 1 Socket box Soleplate of Front Panel Screw ST 2 9X6 embedded the Wired of the Wired in the wall Controller Controller 12 Wired Controller RCW10 Fig 4 2 Fig 4 2 shows the installation steps of the wired controller but there are some issues that need your attention 1 Prior to the installation please firstly cut off the power supply of the wire buried in the installation hole that is no operation is allowed with electricity during the whole installation 2 Pull out the four core twist
2. On Off operation Mode setting are disabled by the remote monitoring Turbo function state Memory function The indoor unit resumes the original setting state after MEMORY oower failure and then power recovery It blinks under on state of the unit without operation of any button SAVE Energy saving function this function is yet unavailable for this unit S 10 11 12 13 14 19 16 7 A FIG 18 E HEATER Electric auxiliary heating function BLOW Blow function O Ambient setting temperature value O OG QUIET Timing value Quiet function two types quiet and auto quiet this function is yet unavailable for this unit N i DN CO Wired Controller RCW10 2 Buttons 2 1 Layout of Buttons 1 2 3 4 Enter Cancel n Made Function Timer On Off o 6 7 8 2 2 Functions of Buttons Table 2 1 e Jr i EN Enter Cancel Function selection and cancellation 24 Running temperature setting of the indoor unit range 16 30 C cow Timer setting range 0 5 24 hr Se setting of the high middle low auto fan speed Mode Setting of the Cooling Heating Fan Dry Auto mode of the indoor unit Function Switchover among the functions of Turbo Save E heater Blow etc Timer Timer setting On Off Turn on off the indoor unit Press them for 5s under off state of the unit to enter cancel the Memory function If memory is set indoor unit after power failure
3. function is shown as Fig 3 9 1 below y Enter Cancel 4 Fan Mode ss EnteriCancel Fan Mode Enter Cap l a Fan Mode O 0 0 u O Oo LEN O co On Off _ Fu h Timer On Off Function Q Timer On Off Turn on the unit without the E heater Press Function repeatedly until go to Press Enter Cancel to activate the function activated the E heater setting status E heater function Enter Cangel Fan Mode e Fan Mode O Q O y co i O Tr Function 7 Timer On Off F Timer On Off Press Enter Cancel to cancel this setting Press Function repeatedly until go to the E heater setting status again Fig 3 9 1 E heater Setting 10 Wired Controller RCW10 3 10 Blow Setting Blow function After the unit is turned off the water in evaporator of indoor unit will be automatically evaporated to avoid mildew In the Cooling or Dry mode press Function till the unit enters the Blow setting status and then press Enter Cancel to active this function When the Blow function is activated press Function to the Blow setting status and then press Enter Cancel to cancel this function Blow function setting is as shown in Fig 3 10 1 Enter Cancel a Fan Mode id Enter Cancel 4 Fan Mode EnteriCancel a Fan Mode O Q a 8 0 BY 8 hr a Cr Ai G O SF O Q Q Function Y Timer On Off FR pn Timer On Off Function Timer On Off Turn on the unit without the Blow Press Function repeatedly until go to Press Ent
4. press Enter Cancel to cancel this function In the Cooling or Dry mode the temperature will increase by 1 C after the unit runs under Sleep1 for 1hr and 1 C after another 1hr After that the unit will run at this temperature In the Heating mode the temperature will decrease by 1 C after the unit runs under Sleep 1 for 1hr and 1 C after another 1hr After that the unit will run at this temperature Sleep setting is shown as Fig 3 7 1 Enter Cancel a Fan Mode Ea Fan Mode i Enter Qancel O O 0000 A O O O k 9 0 0 Function Y Timer On Off v Timer On Off Function X Timer On Off Turn on the unit without the Sleep Press Function repeatedly until go to Press Enter Cancel to activate function activated the Sleep setting status the Sleep function rnrn t E Fan Mode Enter C ncel a Fan Mode Function v Timer On Off ny Timer On Off Press Enter Cancel to cancel Press Function repeatedly until go this setting the Sleep setting status again Fig 3 7 1 Sleep Setting Wired Controller RCW10 3 8 Turbo Setting Turbo function The unit at the high fan speed can realize quick cooling or heating so that the room temperature can quickly approach the setting value In the Cooling or Heating mode press Function till the unit enters the Turbo setting status and then press Enter Cancel to confirm the setting When the Turbo function is activated press Function to enter the T
5. the unit to activate the swing function In this case will blink After that press Enter Cancel to make a confirmation Swing Off When the Swing function is on press Function to enter the Swing setting interface with blinking After that press Enter Cancel to cancel this function Swing setting is shown as Fig 3 6 1 p 2 een derretir Enter Cancel a Fan Mode EnterCancel 4 Fan Mode Enter Cancel A Fan Mode Function 0 Timer On Off 7 Timer On Off jj Function O O e J sa 01129 a Turn on the unit without the Swing function Press Function repeatedly until go to Press Enter Cancel to activate the activated the Swing setting status Swing function EnterMCancel 4 Fan Mode a P Fan Mode O Function v Timer On Off i v Timer On Off Press Enter Cancel to cancel this Press Function repeatedly until go t setting the Swing function again Fig 3 6 1 Swing Setting Notes Sleep Turbo or Blow setting is the same as the Swing setting 2 After the setting has been done it has to press the key Enter Cancel to back to the setting status or quit automatically five seconds later Wired Controller RCW10 3 7 Sleep Setting Sleep on Press Function under the On state of the unit till the unit enters the Sleep setting state After that press Enter Cancel to confirm this setting Sleep off When the Sleep function is activated press Function to enter the Sleep setting status After that
6. On Off Turn on the unit without Timer Press Timer repeatedly until Press A toadjustthe time activated go to the setting status ry rs Enter Cancel Fan J Mode Sod 6 O O amp 7 Function Ti On Off Function Timer On Off be ke Press Timer to cancel this setting Press Enter Cancel to confirm this setting Fig 3 5 1 Timer off Setting under the On State of the Unit 5 Wired Controller RCW10 Timer on setting under the Off state of the unit is shown as Fig 3 5 2 Enter Cancel Fan Mode Enter Cancel Fan Mode l i Enter Cancel ap Fan Mode Ga Q O Oo Of O O O 0 Function e Timer On Off Function z Function Timer On Off ge E se e Turn off the unit without Timer Press Timer repeatedly until Press A to adjust the time activated go to the setting status s Enter Cancel a Fan f Mode Enter Canet a Fan Mode OO Oo O O Function 7 Ti On Off Function Timer On Off Press Timer to cancel this setting Press Enter Cancel to confirm this setting Fig 3 5 2 Timer on Setting under the Off State of the Unit Timer range 0 5 24hr Every press of Aor Y will make the set time increased or decreased by 0 5hr If either of them is pressed continuously the set time will increase decrease by 0 5hr every 0 5s Wired Controller RCW10 3 6 Swing Seiting swing On Press Function under on state of
7. Over phase current protection Hc L N PFC protection Compressor desynchronizing IPM Temperature Protection IPM Current protection Compressor phase loss reversal orotection Frequency restricted reduced with whole unit current protection Frequency restricted reduced with IPM current protection Frequency restricted reduced with high discharge temperature Frequency restricted reduced with anti freezing protection Frequency restricted reduced with overload protection Frequency restricted reduced with IPM temperature protection o Over power protection System charge shortage or blockage orotection TI 00 m Capacitor charging error TI CO High pressure protection L Low pressure protection TI O Compressor stalling mm cS Over speeding PF m O Drive board temperature sensor error Indoor unit full water error m AC contactor protection Anti freezing protection Temperature drift protection PE AC input voltage abnormal U al Sensor connection protection Whole unit current sensing circuit error U3 E N DC bus voltage drop error 4 way valve reversing error L3 O Outdoor fan 1 error protection Motor stalling LA 00 F1 e IZ IN IX EX IN ca IN Pa A IN IN A IN e ca MN MN UN Outdoor fan 2 error protection PG motor zero crossing protection
8. USER MANUAL REMOTE CONTROL RCW10 User Notice Please carefully read this manual before installation and use of this product Ensure unified power supply for each indoor unit Never install wired controller in wet place or under sunlight directly Shielded twisted pair line must be adopted as signal line or wiring communication of wired controller once the unit is installed in the place where there is electromagnetic interference Make sure communication line is connected into correct port to avoid communication malfunction Never knock throw or frequently disassemble the wired controller Never operate the wired controller with wet hand Contents Me o e E EES 1 1 1 LCD Display of Wired Controller ooccooocccccccnncoccnncconnnccononononononnnnnnos 1 1 2 Instruction to LCD Display arrastrar 2 e ee io A 3 2 1 Layout Of Buttons oocccocccocccocncocncnononononononnconnnonnnnnnnnnnnnnnrnnnnnnnnnnnnnnnanenaninos 3 2 2 FUNCIONS Of BULA Sisa tien atte iaiar deci 3 3 Operation Instructions e PP A 4 A ee PR O O 0 O E A 4 3 2 Mode Setting tooo polaca 4 3 3 Temperature Setting ooccccocccccoccncoconocononononnnnonnnnnnnnnnnnnnnnnononencnnannnnnncnnss 4 OF AU SUING PA E E EA essen EEE E T 5 30 LUMEN SONN eea EE E E E E E ES 5 3 6 Swing A 7 E AAA 8 3 8 Turbo Setting axenic otc actcat cece erteinacecenisdeamins anacetusnansendenmmndeemaatinmsstenederannseneccmene 9 3 9 E heater Setting rra iaa 10 3 10 Bl
9. and then power A Mode recovery will resume the original setting state If not the indoor unit is defaulted to be off after power recovery Memory off is default before delivery Fan Y displayed on the wired controller for the cooling only unit while will be displayed on the wired controller for the cooling and heating unit Upon startup of the unit without malfunction or under off state of the unit press them at the same time for 5s to enter the lock state in which case any other buttons won t respond the press Repress them for 5s to quit this state cc By pressing them at the same time under off state of the unit will be Wired Controller RCW10 3 Operation Instructions 3 1 On Off Press On Off to turn on the unit and turn it off by another press Note The state shown in Fig 3 1 1 indicates the Off state of the unit after power on The state shown in Fig 3 1 2 indicates the On state of the unit after power on Enter Cancel Mode Enter Cancel Fan Mode 0000 o0 60 O OO O O 0 G G o Y Function Timer Ono Function Timer On Off Fig 3 1 1 Off State Fig 3 1 2 On State 3 2 Mode Setting Under ON state of the unit press the Mode to switch the operation modes as the following sequence Auto Cooling Dry Fan Heating Fan Heating 3 3 Temperature Setting Press Aor Y to increase decrease the preset temperature If pressing either of them continuously the temperature will be increased or decr
10. eased by 1 C every 0 5s as shown in Fig 3 3 1 In the Cooling Dry Fan or Heating mode the temperature setting range is 16 C 30 C In the Auto mode the setting temperature is unadjustable 2 a 5 z m3 a a 5 Y Q U Q OOOO Function Timer On Off Function Y7 Timer On Off Fig 3 3 1 Fig 3 4 1 Wired Controller RCW10 3 4 Fan Setting Under the On state of the unit press Fan and then fan speed of the indoor unit will change circularly as shown in Fig 3 4 1 Middle _ High 3 5 Timer Setting Under on state of the unit Press Timer button to set timer off of the unit Under off state of the unit press Timer button to set timer on of the unit in the same way e Timer on setting Under off state of the unit without timer setting if Timer button is pressed LCD will display xx Hour with ON blinking In this case press A or Y button to adjust timer on and then press Timer to confirm e Timer off setting Under on state of the unit without timer setting if Timer button is pressed LCD will display xx Hour with OFF blinking In this case press A or Y button to adjust timer on and then press Timer to confirm e Cancel timer After setting of timer if Timer button is pressed LCD won t display xx Hour so that timer setting is canceled Timer off setting under the On state of the unit is shown as Fig 3 5 1 Enter Cancel 4 Fan hi Mode O O O O O Function Timer Function E
11. ed pair line from the installation holes and then let it go through the rectangular hole behind the soleplate of the wired controller 3 Stick the soleplate of the wired controller to the wall over the installation hole and then fix it with screws M4X25 4 Insert the four core twisted pair line into the slot of the wired controller and then buckle the front panel and the soleplate of the wired controller together 5 Finally fix the front panel and the soleplate of the wired controller tightly by screws ST2 9X6 CAUTION Please pay special attention to the followings during the connection to avoid the malfunction of the air conditioning unit due to electromagnetic interference Separate the signal and communication lines of the wired controller from the power cord 13 Wired Controller RCW10 and connection lines between the indoor and outdoor unit with a minimum interval of 20cm otherwise the communication of the unit will probably work abnormally 2 If the air conditioning unit is installed where is vulnerable to electromagnetic interference then the signal and communication lines of the wired controller must be the shielding twisted pair lines 4 3 Dismantlement of the Wired Controller 9 Errors Display If there is an error occurring during the operation of the system the error code will be displayed on the LCD as show in Fig 5 1 If multi errors occur at the same time their codes will be displayed circularly N
12. er Cancel to activate the function activated the Blow setting status Blow function Enter Cancal As Fan Mode 0 0 O 0980 Timer On Off meg el 5 zi fa Function A Timer On Off Press Enter Cancel to cancel this Press Function repeatedly until go to the setting Blow setting status again Fig 3 10 1 Blow Setting Notes When the Blow function is activated if turning off the unit by pressing On Off or by the remote controller the indoor fan will run at the low fan speed for 2 min with BLOW displayed on the LCD While if the Blow function is deactivated the indoor fan will be turned off directly 2 Blow function is unavailable in the Fan or Heating mode 11 Wired Controller RCW10 3 11 Other Functions a Lock Upon startup of the unit without malfunction or under the Off state of the unit press A and Y at the same time for 5s till the wired controller enters the Lock function In this case LCD displays E After that repress these two buttons at the same time for 5s to quit this function Under the Lock state any other button press won t get any response b Memory Memory switchover Under the Off state of the unit press Mode and A at the same time for 5s to switch memory states between memory on and memory off When this function is activated Memory will be displayed If this function is not set the unit will be under the
13. ote In event of any error please turn off the unit and contact the professionally skilled personnel d Enter Cancel A Fan Mode I RL tl UL OO O O Function Y Timer On Off Fig 5 1 14 Wired Controller RCW10 Table 5 1 Meaning of Each Error Return air temperature sensor open short circuited evaporator temperature sensor open short circuited Indoor unit liquid valve temperature sensor open short circuited Indoor gas valve temperature sensor open short circuited IPM temperature sensor open short circuited Outdoor ambient temperature sensor open short circuited Outdoor unit condenser mid tube temperature sensor open short circuited Discharge temperature sensor open short circuited O gt Drive board communication error F2 Compressor overheating protection Q NO 5 al O1 O1 al L ES b5 Indoor and outdoor units unmatched Communication line misconnected or expansion valve error 5 P7 m N Running mode conflict F3 TI O Pump down F4 O Jumper error F5 I Forced defrosting E6 m O Indoor and outdoor communication error Compressor startup failure PL E D DC bus under voltage protection High discharge temperature protection PH m 00 DC bus over voltage protection Overload protection Compressor phase current sensing circuit error m U1 Whole unit over current protection HE y Compressor demagnetization protection
14. ow Setting sroine n EN E E A ERSE EE 11 3 11 Other Functions ooccccoccncccccncccncnncconnnononnnnnnnnononnnnnnnnnnnnnnnnnnnnnnonnnnnnannnnnnns 12 4 Installation and Dismantlement occcoccccccncoccncconccncnconnnnnnncnnnnnnnnonnnnnnanonannnnos 12 4 1 Connection of the Signal Line of the Wired Controller 12 4 2 Installation of the Wired Controller ooccccconcccccccnccocnnoconnnononcnononenonons 12 4 3 Dismantlement of the Wired Controller oocccccocnncccnnnccnonincconononos 14 DEMOS IS DA init 14 Wired Controller RCW10 1 Displaying Part Function M Timer On Off Fig1 1 1 Outline of wired controller 1 1 LCD Display of Wired Controller 12 3 4 6 7 8 9 10 11 Qx_ mcm SSS A E a es li p 12 13 14 15 ig 17 18 19 20 21 Fig 1 1 2 LCD display Wired Controller RCW10 1 2 Instruction to LCD Display Table 1 1 N O Symbols Description Swing function z Air exchange function this function is yet unavailable for this unit Sleep function Only sleep 1 Each kind of running mode of indoor unit auto mode Cooling mode Dry mode Fan mode Heating mode lt G pe Defrosting function for the outdoor unit b b b mun Gate control function this function is yet unavailable for this unit E Lock function SHIELD Shield functions Button operation temperature setting
15. urbo setting status and then press Enter Cancel to cancel this function Turbo function setting is as shown in Fig 3 8 1 N m tas eteeeesesses es Enter Cancel 4 Fan Mode Enter C ncel a Fan Mode Enter Qancel a Fan Mode 56 0 o Gao 0 O O 0 6 Function v Timer On Off F y Timer On Off Function x Timer On Off Turn on the unit without the Turbo Press Function repeatedly until go to Press Enter Cancel to activate function activated the Turbo function status the Turbo function i Enter Gancel 4 Fan Mode Enter Cancel a Fan Mode O O QO Q Function Timer On Off n y Timer On Off Press Enter Cancel to cancel this Press Function repeatedly until go to the setting Turbo function status again Fig 3 8 1 Turbo Setting Wired Controller RCW10 3 9 E heater Setting E heater auxiliary electric heating function In the Heating mode E heater is allowed to be turned on for improvement of efficiency Once the wired controller or the remote controller enters the Heating mode this function will be turned on automatically Press Function in the Heating mode to enter the E heater setting interface and then press Enter Cancel to cancel this function Press Function to enter the E heater setting status if the E heater function is not activated and then press Enter Cancel to activate it The setting of this