Home

to the instructions. - Canadian Agricultural Safety

image

Contents

1. Target Age 7 and up How it works The Bullex Digital Fire Simulator uses LEDs to mimic the look of a fire and senses lasers projected from the fire extinguishers provided As a demonstrator you can choose the level and the class of fire The LEVEL affects how flames will grow diminish and the CLASS controls how the fire will flare up With the right technique the fire will eventually go out Aiming too high or aiming too low will not put the fire out Warnings Ii Read the User s Manual before use i Two people are required to setup the Bullex Mi Children must ALWAYS be supervised when around the Bullex M Make sure the controller cable and battery charger cable don t become tripping hazards i Beware of the risk of electric shock v ALWAYS pick up the monitor by the handles nothing else M Make sure EVERYONE knows these are make believe fire extinguishers Lasers don t extinguish REAL fires IVI The Bullex system should be treated with care to ensure the long life of the unit spe up the Bullex 1 Plug the female end of the black power cable into the rear of the Bullex base unit 2 Plug the male end of the black power cable into a power outlet from the wall 3 Plug the male end of the controller cable into the appro priate connector on the rear of the LCD monitor 4 Plug the female end of the controller cable into the con nector on the handheld controller This should turn the system on 5 On
2. Back Allowing you to manually provide additional challenges for the participant 10 kg fire extinguisher Shuting Down Included in the Kit Shut down the Bullex by pressing the START STOP button Millepimonitor SOP UJALCONNECUONS M 12 volt yellow plugin for LCD monitor Return the hose of the laser extinguisher to the hose clip Aed charger pack for LCD montor V Handheld controler v Black cord for handheld controler j4 kg and 10 kg fire extinguishers Packing Up Make sure the system has been properly shut down Finda buddy to help pack Fold in the feet of the LCD monitor as much as possible ALways pick up the monitor by the handles nothing else v Two fire extinguisher battery chargers V Two black cases ae I VJ Instructions Pack the extinguisher in the case provided Be careful not to knock or drop any of the units during transportation Growing Cultivons Forward l avenir ii ef amp Agriculture and Agriculture et A tederal provincial territorial initiative Agri Food Canada Agroalimentaire Canada Une initiative f d rale provinciale territoriale
3. the participants to slowly approach the 6 ft 1 8 metres marker Using the PASS Technique the participant should Pull the extinguisher pin Aim the hose at the base of the fire Squeeze the handle and Sweep the extinguisher f the participant properly aims and sweeps the extinguisher the flames will eventually go out and the participant s time will be displayed on the handheld controler The key is to aim and sweep to extinguish the flames Flames have the ability to com rekindle or flare up if not fully extinguished C The extinguishers are designed to provide the participant with a discharge time that corresponds to an actual dry chemical extinguisher of the same size As with actual Ses extiguishers Bullex training extinguishers are most effective during the first several j seconds of discharge The Bullex system can also detect the distance of the participant from the flame If the participant gets too close to the digital fire the flames may be more difficult to extinguish This simulates the sometimes dangerous effects of getting on top of a fire and helps reinforce the behavior of remaining at a proper distance from a fire The digital flames can be stopped at any time by pressing and releasing the start stop button If the trainer presses and holds the START STOP button the system will begin a flame Die Down mode and the digital flames will gradually diminish If the button is released the flames will Grow
4. ce plugged in the handheld controller will read Bulls Eye v1 By BullEx Inc 6 One second after Bullex is powered up the handheld controller will display Read Manual Before Use Please do 7 Press and release the START STOP button once 8 Make sure to select Laser mode by adjusting the top black knob to the desired setting and then press and release the START STOP button once If Water mode is Smart tip selected the system will not work 9 To change between Laser and Water modes simply Make sure to unplug the controller cable from the handheld controller recharge the batteries wait two seconds plug in again and start over of the fire 11 The Handheld Controller will now display Ready 12 Mark the ground 6 feet away from the Bullex panel The extinguishers laser extinguisher sizes are to be used 6 feet from the before and after panel 13 Insert the pin into the handle of the extinguishers your activity 14 Press the power switch under the hose on the side of the extinguisher You will see the green light turn on 15 The laser will emit when the user pulls the pin removes the nozzle from extinguisher clip and then depresses the handle The 10 kg extinguisher s discharge time is longer than the 4 kg extinguisher s 16 To reset the extinguisher simply replace the hose into the hose clip 17 After 45 seconds without use the extinguisher will chirp and turn itself o
5. ff 18 Please recharge the batteries every 3 hours of use 19 Do not leave the extinguishers or LCD screen plugged in for more than 12 hours if they re not being used MP CASA ACSA Canadian Agricultural Safety Association Association canadienne de s curit agricole Changing the Class of Fire Simulation The Bullex can simulate different classes of fire including Class A B and C fires The fires all respond differently to allow for a more thorough training session For example Class A fires respond by gradually extinguishing with the proper application of extinguishant while Class B fires are easily knocked down by a single sweep but are quick to flare up if enough extinguishant is not discharged Return Address Canadian Agricultural Safety Association 3325 C Pembina Highway Winnipeg MB R3V 0A2 Canada For more information visit www planfarmsafety ca Use the MODE selector knob to select the class of fire to simulate or call 1 877 452 2272 Select A for Class A Common Combustibles fires Select B for Class B Flammable Liquids fires Select C for Class C Electrical fires Conducting the Demonstration When the system is set up according to the instructions on the back of this page press the START STOP button on the handheld controller You will hear an initial warning beep and the flames will begin to grow Instruct one of

Download Pdf Manuals

image

Related Search

Related Contents

Manual do Motor LEO  Hafler DH-200 User's Manual  NAMCO Bandai Games 90500126 User's Manual    

Copyright © All rights reserved.
Failed to retrieve file