1. 841 ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS s velemen components USER MANUAL USER MANUAL 841 ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS INTRODUCTION The HAM841K HA 841K is a complete alarm control panel designed for commercial and residential security systems and equipped with the latest electronic control technology It has the highest level of quality and reliability The exceptional Specifications incorporate many features that are generally only found in advanced professional systems The HAM841K HA 841K accepts active and passive sensors detectors to form a versatile protection system ADJUSTS DURATION OF 24 ADJUSTS DURATION OF ADJUSTS DURATION OF HOUR PANIC FIRE SIREN BURGLARY SIREN ENTRY DELAY ALARM STATUS INDICATOR TEST OPERATE POWER ON OFF SELECTOR KEY SWITCH MAIN POWER 24 HOUR ON OFF SWITCH CABINET LOCK PANIC BUTTON CONNECTION TERMINALS SEE DESCRIPTION FOR DETAILED INFORMATION BATTERY COMPARTMENT WIRE FEED NOTES FOR INSTALLING TECHNICIAN THROUGH HOLES The HAM841K panel is extremely reliable Use the check list at the back of the manual in case of trouble Recheck all the wiring if the list does not help INTERNAL CONTROLS 1 Main Power Switch Enables the user to disconnect or connect the power 2 Test Operate Switch This switch allows the installer to test the panel without activating t
2. N O Delayed alarm Circuit This circuit has the same function as 5 amp 6 but it N O circuit the contact must be open under normal circumstances Ideal for pressure mats ALARM SENSOR BOWER aa CONTACTS elojellel FIG 5 N 0 DELAYED ALARM CIRCUIT Terminal 9 amp 10 Connections for Internal Battery Charger These terminals should be linked to connect the internal battery charger to a rechargeable battery we strongly advise you to use a 12V rechargeable battery 2 FIG 6 CONNECTIONS FOR RECHARGEABLE BATTERY DO NOT CONNECT WHEN USING STANDARD BATTERIES HAM841K 5 GB Terminal 11 amp 12 Siren speaker output These terminals provide a high level siren signal that drives up to two 8 ohm horn speakers Shorting these terminals or using more than 2 speakers will result in serious internal damage The control panel has an internal alarm that will sense when the speaker wires are cut Consequently the 1K ohm resistor installed across the terminals should be left in place if no speaker is connected Remove this resistor if a Speaker is connected POWER TATAN NOTE LINK 11 6 12 WITH A 1K OHM RESISTOR IF NO SPEAKERS ARE CONNECTED 8 OHM SPEAKERS MAX 2 FIG 7 CONNECTION FOR SPEAKER SIREN Terminal 13 amp 14 Alarm relay co
3. open terminals 2 amp 3 should be shorted if the alarm is not activated Terminals 5 amp 6 are open They should be shorted if the alarm is not activated Terminals 6 amp 7 are shorted should be open Terminals 9 amp 10 are not linked should be linked in order to charge the battery NOTE When using standard batteries do not link terminals 9 amp 10 to the battery use a 12V rechargeable battery Test Operate switch is in the test position Wiring is cut 1Kohm resistor has not been removed Key switch is not in the Incorrect wiring N O switch is wired in series or N C switch is wired in parallel CONNECTION TERMINALS WAIN POWER RECHARGEABLE BATTERY CONNECTED OPER NORMAL BATTERY OPEN pcre 24 HOUR 0 INSTANT FIRE SMOKE N C SENSOR LJ a N C SWITCHES SIREN DRIVER OUTPUT 8 Q HORN SPEAKER MAX TWO MAX HAM841K OUTPUT FOR ALARM RELAY CONTACT 3AMP MEMORY RELAY CONTACT 12VDC A REMOTE KEY SWITCH WITH CUT WIRE PROTECTION OUTPUT FOR ALARM 3AMP MAX POWER IN TEXT
4. CTS SHOULD BE WIRED IN SERIES FIG 2 INSTANT ALARM CIRCUIT Terminal 4 Alarm status indication Terminal 4 allows the connection of a low current LED with the same function as the Exit Alarm LED It can be used on external key switches in order to provide an indication of the alarm status The cathode terminal normally indicated by a Small flat on the plastic body adjacent to the lead The cathode is the shorter of the two leads of this LED is connected to terminal 4 and the anode terminal is connected to the positive power connection terminal 21 This circuit does not require a resistor as the control panel is equipped with an internal resistor Reverse the connections and try again if the LED does not work LEDs are available from electronic supply stores a CATHODE ANODE a SMALL FLAT INTERNAL MAIN POWER ON OFF ANODE CATHODE FIG 3 REMOTE ALARM STATUS INDICATOR HAM841K 4 GB Terminal 5 amp 6 Delayed alarm Circuit This circuit is controlled by the alarm on off key switch It should be used for any area requiring a delay between the moment of detection and the activation of the siren These contacts should be N C i e terminals 5 amp 6 should be shorted under normal circumstances The delay is adjustable from 0 5 sec to 90 seconds by using the control marked entry delay ALARM SENSOR VEH POE r 7 CONTACTS FIG 4 DELAYED ALARM CIRCUIT Terminal 6 amp 7
5. MINAL FOR SWITCHABLE 12V POWER SOURCE Terminal 20 21 and 8 These terminals are used for remote key switches If no remote key switch is used terminals 20 and 21 should be shorted in order to disable the internal alarm that senses wire cutting There are two ways to connect a remote key switch to the panel Both methods see diagram will activate an internal alarm if the wiring is cut BUY 1 FIG 13 KEYSWITCH WITH CUT WIRE PROTECTION MAIN POWER METHOD 2 ON OFF METHOD 2 NOTE TEST TERMINALS 20 amp 21 MUST BE LINKED FIG 14 REMOTE KEYSWITCH WITH CUT WIRE PROTECTION NOTE The key switch on the panel should be left in the on position when an external key switch is being used Both methods of remote key switch connection are secure the alarm will be activated if the wiring is cut HAM841K 8 GB PROBLEM CHECKLIST PROBLEM BEEPER KEEPS SOUNDING INSTANT LED PERMANENTLY ON DELAY LED PERMANENTLY ON LOW BATTERY INDICATION SIREN WILL NOT SOUND INSTANT ALARM DELAYED ALARM CIRCUITS DO NOT WORK POSSIBLE CAUSE Verify whether the speakers are connected When no Speakers are used the 1Kohm resistor should be connected across terminals 11 amp 12 Terminals 20 amp 21 are not linked Weak battery Test O perate switch is in Test position Beeper sounds during exit period Terminals 1 amp 2 are shorted should be open Terminals 2 amp 3 are
6. he siren or the relays In the test position the siren is replaced by the internal buzzer that beeps 2 seconds on 1 4 second off during the alarm period This switch should be placed in the operate position for the siren and relays to operate normally 3 Duration Siren 24h Panic Function Fire Determines the length of time the siren will sound before resetting when it is triggered by the 24hr instant alarm circuit This circuit is adjustable from 30 sec to 3 min 4 Siren Duration Burglary Determines the length of time the siren will sound before resetting when it is triggered by the N C Normally Closed instant alarm circuit or by the N C or N O Normally Open delayed alarm circuits The activation period is adjustable from 30 sec to 3 min 5 Entry Delay Determines the duration of the delay from 0 5sec to 90sec 6 Key Switch Switches alarm circuits on off and does not affect the 24hr instant alarm circuit HAM841K 2 GB 7 Panic Button Connected internally to the 24hr instant alarm circuit Pressing this button will activate the siren regardless the position of the key switch LED INDICATIONS Exit Armed GREEN This LED indicates the status of the alarm The exit period 60 sec begins when the key switch 15 put in the position The LED will flash and will then remain lit continuously when the exit period ends The LED will be extinguished if either the instant alarm ci
7. intervals Tamper Alarm 2 second BEEP at 1 4 second intervals Short 20 21 to deactivate the alarm Horn Speaker Wire Is Cut 2 second BEEP at 1 4 second intervals 1K resistor between 11 12 to deactivate the alarm if terminals 11 amp 12 are connected by 1KQ resistor HAM841K 3 GB CONNECTIONS Terminal 1 amp 2 24 hrinstant alarm circuit This circuit is monitored round the clock and is unaffected by the alarm key switch This is a normally open circuit It can be used for fire and smoke detectors panic switches and tamper circuits Note these two terminals must remain open i e no connection should exist between 1 amp 2 when all switches and sensors are in their normal reset positions y PANIC ae SMOKE FIRE FIG 1 24HR INSTANT ALARM CIRCUIT wore SENSORS note CONTACTS SHOULD ele i BE WIRED IN PARALLEL miele Terminal 2 amp 3 Instant alarm Circuit This circuit is controlled by the alarm on off key switch Use it to connect any area that requires protection without using a delay between detection and the sounding of the siren motion sensors window switches window foil tapes etc can be connected here The contacts of these sensors should be shorted when in the normal reset condition and they should be arranged in a series loop see figure 2 MAIN POWER ON OFF TEST 2 NOTE CONTA
8. ity terminal 17 is positive terminal 18 is negative IMPORTANT The standard Velleman version of this productis supplied with 13 8VDC power supply If you do not know which type of panel you have you should check the area behind the terminals under the main circuit board If you have a 16V AC panel you will find a small auxiliary circuit board of approx 50 x 25mm in this area Note the DC input voltage should be 13 8V or 14V to ensure correct charging of the battery re 16VAC OR WE 13 8VDC _ 4 FIG 11 POWER INPUT CONNECTION FOR AC OR DC POWER SUPPLY HAM841K 7 GB Terminal 19 Switchable power output This terminal provides a 12V DC output of max 0 5 Amps thatis switched by the alarm on off key switch It can be used to supply ultrasonic or microwave motion detectors etc Avoid connection of infrared detectors to a switchable power supply The PIR detectors should be connected to a permanent 12V power supply terminal 21 in order to ensure stable and reliable operation Connect the PIR detectors as follows Positive connection of the PIR detector to terminal 21 and the negative connection to terminal 6 Ae d WY 5 CFF Fer MICRO WAVE ULTRASONIC 22 2 8 2 DETECTORS al NOTE CONNECT INFRARED DETECTORS TO TERMINAL 21 INSTEAD OF 19 500mA MAX FIG 12 TER
9. ntact This is a single contact that shorts when the alarm sounds and deactivates when the alarm resets It can be used to switch strobes and self contained sirens etc Power is taken from terminal 10 and switched through the relay contact Note A max of 1Amp is available at terminal 10 Use an external supply when more current is needed The max current is 3 Amps see figure 9 BLU WER ciate FIG 8 ALARM RELAY CONNECTION VEN FAFA cl U EXTERNAL SUPPLY 3 AMPS FIG 9 RELAY CONNECTION FOR HIGHER CURRENTNVOLTAGE HAM841K 6 GB Terminal 15 amp 16 Alarm memory relay contacts These contacts operate at the same time as the alarm relay contact However the contacts remain activated until the power is turned off or the alarm key switch is turned off on off same as the Alarm Memory LED It can be used to provide an external indication of the fact that the alarm has been triggered alarm memory Again the max current for the contact is 3 Amps Power is connected in the same way as with terminals 13 and 14 FIG 10 ALARM MEMORY RELAY CONNECTION REMOTE ALARM MEMORY INDICATION Terminal 17 amp 18 Power input The polarity of these terminals is irrelevant if you have a 16V AC panel Simply connect the two wires from the plug pack to these terminals If you have a 12V DC panel you should be careful to connect the power supply using the correct polar
10. rcuits or delayed alarm circuits are activated RED The function of this LED is duplicated on terminal 4 so that remote indication can be used Instant alarm Circuit LED RED This LED will light whenever either of the instant alarm circuits 24hr or N C is operated while the key switch is in the Delayed alarm Circuit LED RED This LED will light whenever either of the delayed alarm circuits N O N C is operated while the key switch 15 in the Alarm Memory LED GREEN This LED will light when the alarm is triggered and will remain lit until the main power switch is turned off or until the key Switch is turned off on off The alarm was triggered in your absence if this LED is lit Battery Low LED GREEN This LED will flash once every 2 sec when the battery voltage drops below 11 5 Volts AC Power LED AMBER This LED indicates that power is supplied to the panel main power switch is in the on position It should remain lit continuously The backup battery will supply the necessary power if the main power switch is in the and this LED is not lit Restore the primary power source as soon as possible INTERNAL WARNING TONES Exit Delay Period Short BEEP at 1 2 second intervals Entry Delay Period 2 second BEEP at 1 4 second intervals Battery Low Indication Short BEEP at 2 second intervals Alarm Test Mode 2 second BEEP at 1 4 second
Download Pdf Manuals
Related Search
Related Contents
ダイキン P256TXV Operation, Installation, and Service Manual Manuale Istruzioni SoundLink Bluetooth Serie 3 Kingston Technology ValueRAM Memory 128MB 133MHz Non-ECC CL3 SODIMM Melissa ide line 770-056 User's Manual Hunter HEPAtech D-Link DSL-210 User's Manual NEW! - AM Leonard Gardeners Edge Copyright © All rights reserved.