EPLAN 5 Basic Training
Contents
1. Modification date Automatic 03 Jun 2003 14 46 32 Manual XI Check the results of the creation by calling the table of contents pages up in the graphics editing module You can change the parameter settings at any time and repeat the generation run The previous table of contents pages will be deleted permanently from the project Furthermore you can remove the table of contents from the project by following the menu path Extras gt Table of contents gt Delete EPLAN 5 Basic Training Updating a Table of Contents Project gt Graphics editing output gt Extras gt Table of contents gt Update lf you had already created a table of contents and added additional pages to the project afterwards the table of contents must be updated To this purpose EPLAN provides an update function which can be called up in graphics editing under Extras gt Table of contents gt Update This function is also used if the page designation or the name of the creator was changed on an already existing page EPLAN 5 Basic Training Backing up Data Much has been written about backing up your data We will only soend a few minutes adding our thoughts Losing data as a result of for example damage to the hard drive a virus or accidental deletion can have disastrous results for your company In order to lose as little as possible if the worst happens you should e Back up all projects that you are working on d
2. e f you use your own unique symbol files macros plot forms etc in your project you must also supply the corresponding files so that the recipient can actually work with the project To this purpose select the Backup or Backup with print forms radio button in the Project specific files group box of the Backup dialog box e lf you only use those files that form part of the standard EPLAN delivery to create your projects you do not need to select the options mentioned above for backing up associated files Backing up Further Data In addition to those data already mentioned the following file groups can also be backed up with the data backup module in each case the base directory is shown Master data EPLAN4 N Macros EPLAN4 M Parts data EPLAN4 L Print and control forms EPLAN4 F Personal and workstation data EPLAN4 O Once the desired menu item e g Macros has been selected from the Backup menu the Backup dialog box appears Compared to the project data backup only a few parameters can be specified here In the subsequent Directory selection dialog you can select the directory whose files are to be stored If the Individual selection option was set in the Backup type group box of the Backup dialog box a file selection must be made afterwards The further procedure to back up data corresponds to the procedure when backing up project data EPLAN 5 Basic Training Reloading Projects To reload data use the R
3. Cable definition Terminal target Three phase motor DRIVE left right Function text EPLAN 5 Basic Training Terminals are added in the same way as normal devices Here too a list window is displayed from which you select the desired terminal whereby the terminal s graphic appearance is shown in a preview window on the screen When you have inserted a terminal at the desired position by single clicking it a dialog box opens in which you have to enter the terminal s properties You can subsequently change these properties by positioning the cursor on the terminal s insertion point and pressing Le or the left hand mouse button Since terminals and terminal strips are managed by EPLAN in a project specific database you can use the system supported terminal assignment function in the Designation input field to have the existing data displayed and to assign new terminal numbers 4 Terminal selection Supplementary iv data WINT 1 EPLAN 5 Basic Training Note that an up to date terminal and interconnect diagram must exist In contrast to X terminals device end terminals that you add by either pressing or activating the appropriate icon in the Insert toolbar are not treated as devices Instead these terminals merely represent connections for devices and are therefore not shown in the terminal diagram cf the section entitled Inserting Device end Terminals Multi level Terminals in EPLAN
4. Multi level terminals are used when specific control panel or mounting panel measurements must not be exceeded and thus a space saving wiring is required A large number of terminal types is offered by the manufacturers which differ in the field of application and in the designation A rough difference is made between multi level terminals with independent levels and multi level terminals with connected levels Multi level Terminals with Independent Levels This terminal type includes several terminals that lie one upon the other but have no conducting connection The names usual tn trade are Double level terminals Installation terminals Initiator terminals Actuator terminals Shield terminals Three wire terminals etc gt special form of these terminals integrates all connections of an initiator e g proximity switches or actuator e g valve coil This results in an extremely high wiring density The highest level is used as passage for the signal line whereas for example on the middle level the minus potential and on the lowest level the plus potential of the initiator power supply is distributed over snappable insertion bridges EPLAN 5 Basic Training Multi level Terminals with Connected Levels A multi level terminal with connected levels is a terminal that disposes of more than two physical screwing possibilities Since according to DIN two conductors can be clamped under each screw up to 12 conductors can
5. The file off function is used to copy the project to the target data medium for additional external editing or modification The original project is then locked to prevent any modifications being made to it Thus only the filed off project can be changed You can however open the original project on a read only basis Filed off projects are marked by special graphics symbols in the project selection windows If the project has been compressed additionally a different symbol is used Cf the listing of symbols in the section Backing up and Reloading Data in this chapter Archive Archiving is used to file completed projects to a target data medium The entire original project is deleted from the current hard disk leaving only an information file Archived projects are also identified by a special symbol in the project selection windows Specifying the Extent of the Backup You can specify the extent of the backup operation That is you can define which files are to be included during data backup Your options here are Backup type C According ta control file All files in the directory Selected files see Help i adividuel selection EPLAN 5 Basic Training According to control file When this option is used the system backs up only those files in the directories specified in the control file The control file allows you to precisely define which files from which file groups are to be backed up The section on
6. uf ePLAN 5 Training Manual Basic Training Version 5 50 August 2003 FRIEDHELM LOH GROUP EPLAN Copyright 2003 EPLAN Software amp Service GmbH amp Co KG EPLAN Software amp Service GmbH amp Co KG assumes no liability either for technical or printing errors nor for deficiencies in this technical information and cannot be held liable for damages that may result directly or indirectly from delivery performance and use of this material This document contains information on the basis of a proprietary system that is protected by copyright laws All rights reserved This document or part of this document may not be copied or reproduced by any other means without the previous permission of EPLAN Software amp Service GmbH amp Co KG The software described in this document is subject to a license agreement The software may only be used and copied within the scope of this agreement EPLAN and LOGOCAD TRIGA are registered trademarks of EPLAN Software amp Service GmbH amp Co KG MS DOS Windows NT Windows 2000 Windows XP Microsoft Windows are registered trademarks of Microsoft Corporation Microsoft Excel and Microsoft Access are registered trademarks of Microsoft Corporation RITTAL is a registered trademark of the Rittal Werk Rudolf Loh GmbH amp Co KG Clip Project is a registered trademark of the Phoenix Contact GmbH amp Co INTERBUS is a registered trademark of th
7. A function text Function text text type can be specified at a PLC end terminal when a PLC end terminal is inserted as well as when a text is inserted in graphics editing The function text for the PLC end terminal takes precedence during the evaluation The connection designation entered on the PLC overview page at the PLC end terminal can be written back to the PLC page by selecting the menu path from the main menu Generate gt PLC generator gt Generate gt Write connection numbers back to schematic The function text as well as the symbolic address can be displayed on PLC pages by opening the PLC generator module and then selecting Parameters gt PLC data EPLAN allows you to generate symbolic addresses by means of the PLC generator You can decide whether a DD target tracking is to be carried out EPLAN 5 Basic Training Cables In EPLAN you can define the characteristics of cable definitions and of the wiring which will be used during the evaluation runs Use the Cable definition function to add specific cable definitions to the schematic by hand These definitions deviate from the general entries you made in the parameters program Definitions you add in this way will then be evaluated in both the terminal and interconnect diagrams In addition you can also define a cable between two symbols that are no terminals Proceed as follows to define a cable Press Ca irs or click the ttt icon in the Insert toolbar or select
8. If you use the variation with page prefix the number of the page which contains the device is prefixed to each device during evaluation runs For example F1 becomes 19F 1 if this device is used on Page 19 The same variations already known to you from page numbering are available for numbering to DIN Depending on the selected numbering method the higher level assignments and location designations are positioned at the front A component K1 which is to be displayed with the selected numbering method With identifying higher level assignment and location designation is for example displayed as HLA 1 LOD 1 K1 Fr Note that the specified numbering methods only have an effect on automatic evaluation runs Only the device designation is displayed in the schematic Specifying the Designation Methods for Terminals Cables and Interruption Points EPLAN supports seven different designation methods for terminals cables and interruption points EPLAN 5 Basic Training EPLAN Page Types As a rule an EPLAN project consists of pages of different types The page types can be differentiated according to several criteria e Logic page or graphics page e Page created interactively or automatically Logic pages lf a page was created as a logic page this means that EPLAN can process the information saved on it for the automatic generation of lists and diagrams Graphics pages In general logic information cannot be sto
9. Select the desired address and confirm it by clicking OK The address will then be written to the PLC end terminal Situation 2 You insert the PLC end terminal into an I O board which does not contain a device designation The list of the selection dialog box then shows the free addresses of all I O boards used in the project When you highlight an address in the selection dialog box and confirm with OK EPLAN takes over the device designation of the I O board contained in the address and writes it to the I O board currently edited Please note that no DD is taken over at the I O board if you manually change the address after a system supported selection has been made EPLAN 5 Basic Training Situation 3 You insert the PLC end terminal outside an I O board The list of the selection dialog box then also shows the free addresses of all I O boards used in the project Once you select an address in the selection dialog box and confirm the dialog box with OK EPLAN takes over the selected address at the currently inserted PLC end terminal without considering the device designation Fr lf you want to change the symbol properties of several PLC end terminal at one go by using the block editing function it is not possible to make a system supported PLC address selection Corresponding address Numerous PLC manufacturers allow to feed sensors directly via operating voltage carrying terminals which are also contained on the I O board
10. Use this button to accept changes Blank entry Use this button to empty all fields in the dialog box The previously displayed field of the contactor specification file remains unchanged After having filled the fields you can transfer the entries by clicking on the New button Delete This function allows you to delete the record displayed in the Contactor specification window after a prompt for confirmation Close Use this function to close the dialog box A prompt for confirmation is displayed if you have not yet saved the changes you made in the current record Fr lf you have specified new contactors or renamed existing contactors in the contactor specification file you should also enter the corresponding records for the new contactors in the parts master data EPLAN 5 Basic Training Terminals The next sections will provide you with information on the following topics Inserting Terminals Multi level Terminals in EPLAN Defining Terminal Properties Inserting PLC End Terminals Inserting Terminals Terminals are considered to be devices and are inserted from the symbol file in the same way as general symbols The symbol name always begins with an x Note that EPLAN only evaluates these terminals for the terminal diagram However the evaluation programs recognize the terminal properties from the information on the symbol type not from the symbol name Terminal targets Power contacts Terminal strip
11. component specific data such as the part number for a main element You can assign n 1 components with the same DD to act as auxiliary elements Pair Cross references at Contacts Cross references between contacts are used to represent the interdependencies between contacts when the component in question is not a contactor This applies for instance to the auxiliary contacts of a motor overload switch In this case two contacts with the same connection designations are used in the schematic That is the same DD or the same contact occurs twice Pair cross references are entered in the same way as symbol cross references Symbol type Contact as a contactor contact 0 15 Contact with cross reference below the symbol 151 main element Contact with cross reference next to the symbol Contact with cross reference below the symbol 154 but rotated by 90 7 Notes Note that two symbols with both the same device designation and the same connection designation may only be used if contacts have been pair cross referenced In addition the use of the same device designation means that only half as many pairs can be used as the maximum number specified in the Maximum number of contactor contacts parameter Furthermore please note that it is not allowed to use symbol and pair cross references at the same time for one device designation EPLAN 5 Basic Training Counter Cross reference The cross references of contacts a
12. or positions via the numbering program e Projects have been created or modified by other programs In addition EPLAN creates an exact error list when generating cross references Error free cross references are a prerequisite for evaluating the following program sections Wiring list Contactor selection Terminal and interconnect diagram Device list You can use the correction function to have some cross reference errors as a general rule those errors that mostly occur automatically eliminated Please refer to the following sections for more information on the topics e Generating Contact Cross references e Creating Interruption Point Cross references e Generating Cross references according to IEC 1082 1 Generating Contact Cross references This subchapter is about the creation of contact cross references First you will get to know the various types of contact cross references and afterwards you will learn how to generate contact cross references according to the IEC 1082 1 standard Finally we will describe how to start a contact cross reference run EPLAN 5 Basic Training Contact Cross reference Types It is often necessary to display the same device several times The fact that the corresponding symbols belong to this device is recognized by the fact that all the symbols have the same device designation and are represented by the corresponding symbol type The contact cross reference shows where the other par
13. Data Backup Defining Default Settings Utilities gt Backup gt Parameters Prior to a data backup you may have to make various default settings For this purpose the Data backup utility offers the following menu items or parameters e Drive e Input Output If you want to carry out a data backup via a control file you must adjust the control file beforehand The following section gives details on the above mentioned parameters and the control file for the data backup EPLAN 5 Basic Training Drive You can use the Drive menu item to temporarily change the Data exchange drive see below specified in the input output parameters 4 Drive selection 4 Removable medium C Hard disk D CO ROM H Network J Network We Network To do this select the drive on which you want to carry out a data backup or from which you want to reload data in the Drive selection dialog box All the available drives are displayed If you click on the Save permanently check box the drive selected here is applied as Data exchange drive in the input and output parameters Input Output Use the Input Output menu item to define the workstation specific parameters for the data backup The following parameters are available e Data exchange drive This is the drive on which the data are saved during the data backup process or from which the data are read during a reload process e Compress data e Use old backu
14. EPLAN can manage up to 26 subpages for each primary page A through Z or a through z In this case the table of contents can have a total of 27 pages for each primary page the primary page itself 26 subpages If the project table of contents is too large to be displayed on the available subpages EPLAN automatically creates a follow on page In this case EPLAN recommends a Starting page for the insertion of the table of contents so that all pages in the table of contents appear sequentially in the project Number of blank pages Use this parameter to specify how many pages will be left blank between the most recently used page and the table of contents EPLAN 5 Basic Training Round up to page This parameter which operates together with the Number of blank pages parameter is used to specify the page number from which you want the table of contents to start Both parameters are set as follows Number of blank pages 4 Round up to page 10 Case 1 Let us assume the last page number is 47 gt The table of contents will then start on Page 61 Explanation The last page number is 47 You have to add 4 blank pages which results in 51 as last page number This result is rounded up the next full 10 so that the last page is 60 Therefore 61 is the first page number of the table of contents Case 2 Let us assume the last page number is 46 gt The table of contents will then star
15. Editing the Control file in the previous chapter provides you with more detailed information about the control file structure All files This option backs up all files belonging to the respective file group This option is primarily used when archiving data Selected files lf you use this option you can only back up those files that are required for project pages Files derived from the project pages such as cross references terminal diagram and bill of materials are not included in the backup Individual selection This radio button can only be activated if master data macros parts data print and control forms or data from the personal directory are backed up You can then individually select the directories and files which are to be included in backing up Deleting files no longer required The following settings are possible here Delete databases Backup files Backup pages 7 455 T Search databases Backup files This includes various backup files that are created during the execution of the program such as the backup pages which are created before a compression is carried out etc Back up pages ass Select this check box if you want to delete the backup pages that EPLAN generates automatically in accordance with the setting of the personal Number of page in page buffer backup parameter EPLAN 5 Basic Training Search databases This check box can be used to specify that the project sp
16. EpLan4 directory structure All the projects must for example exist below the directory EPLAN4 P or its subdirectory If you specify an invalid directory EPLAN draws your attention to this fact when you leave the dialog box If you have specified several directories which do not exist you can decide whether EPLAN should create all of them or only individual ones EPLAN 5 Basic Training Editing Projects The following overview provides a list of functions that are available in the Project selection dialog box For the most part these functions can be carried out via corresponding buttons in the dialog box as well as via menu options in a pop up menu To call up the pop up menu the cursor must be located in the directory tree of the Project selection dialog box Current project directory Project properties DEMO E DE PLAN PSCC Fages Directories Data backup Type of project a D5 General 1 General 2 Customer End user E diting Status ET Plant designation Demoa tt Ga FORK Drawing number jEDo02 t itsi si i i S cae MAK Commission EPLAN INTERNATIONAL H 0 PLAN Company A Name EPLAN Software amp Service GmbH amp Co KG Address 1 An der alten 2ieqelei 2 Address 2 40769 Monheim Supplementary fields u BEMORE o 3 EPLAN CUSTOMER gt s s 3l 4 5 El 7 Drives New Rename E
17. KKS YD HLA 1 LOD 1 1 YE HLA 1 LOD 4 1 Specifying Subpages In all page numbering types you can assign so called subpages to the existing project pages This can be relevant for example if you have to insert additional pages into an existing project Subpages are created by specifying the number of the corresponding main page followed by a numeral or a character In a project with serial numbering 10 3 or 24 C would therefore be valid designations for subpages EPLAN 5 Basic Training Specifying Designation Methods Designations or identifiers are used to identify devices within an electrical project Devices include individual components equipment assemblies functional units etc that are each represented in the schematic by a graphics symbol The identifier provides the following information e Interrelationships between the device and other parts of the plant e Mounting location of the device e Identification of the device by its type counter number and function EPLAN supports the designation methods for devices terminals cables and interruption points specified in DIN 40719 Part 2 EPLAN supports six device designations methods lo Serial no page prefixes Serial no page prefixes 1 Serial with nage prefixes Oe 2 DIN HLA and LOD 3 DIN HLA deser LOD EPLAN 5 Basic Training In the case of serial numbering the devices are identified exclusively by the device designation
18. N EPLANKKABEL KLB lflex 101 Cancel Cross section If the form used contains a corresponding field the cross section entered here will be imported into the terminal and interconnect diagrams The maximum cross section is 655 If the cross section of a PE conductor is different to those of the other conductors you can use a as a separator and thus enter two different cross section values e g 150 80mm Fr Keep the no of conductors in mind for this specification If for example you entered a 4 into the No of conductors field and the entire entry is therefore 4 x 1 5 2mm 7 the cable does not dispose of 4 but of 5 conductors Length The value you specify in this field will be used during cable definition in the terminal or interconnect diagram if a corresponding field exists in the diagram form The length can be entered with decimal values or you can enter a unit in this field An entry depends on the type of form you are using If you are using the standard forms supplied by EPLAN Software amp Service you must define the unit of measurement If you do not specify a particular unit of measure the value specified in the corresponding parameter will be used EPLAN 5 Basic Training Voltage The value for the voltage is entered in this field It is not evaluated at present Special cable Use this check box to specify whether the cable is to be evaluated as a special cable This means that if the d
19. You can specify a so called Corresponding address for these supply terminals to assign them to the signal transferring addressed PLC terminal This field can only be edited if you have selected Power supply for the Type of connection Connection description This field is used to enter a connection designation for one of the following connection types Not specified Digital input Digital output Analog input Analog output Board power supply Bus This field cannot be edited if the Power supply type of connection is selected EPLAN 5 Basic Training Type of connection You can select among various types of connection for a PLC end terminal The following options are available Not specified Digital input Digital output Analog input Analog output Power supply Board power supply Bus Connection subtype In addition connection subtypes can be selected for the Power supply Board power supply and Bus types of connection In case of Power supply and Board power supply you can determine whether the connection has a plus potential minus potential or PE conductor potential if it is intended for the connection of a shielding or if it is not specified at all In case of Bus you can decide whether the connection is an input or an output or is not specified at all Symbolic address not available on PLC overview pages If necessary enter the symbolic address of the PLC end terminal here Symbolic addresses may cont
20. at any time into a symbol or form project This means that you can include for example sheets for plot forms terminal diagrams interconnect diagrams etc in a schematic project and use them correspondingly when required Specifying the Page Numbering Type The page numbering type you specify determines how the project pages will be managed EPLAN supports the following page numbering types which you can specify via the dropdown list box in the Page numbering type field Seral numbering Seral numberine e Serial numbering e DIN page numbering e KKS page numbering German power station numbering system The individual page numbering types are explained in the following sections AA Once you have created a project you can no longer change the page numbering type because the structure of the database in which the project is stored depends on the selected page numbering type The field is therefore grayed and cannot be edited when you call up the Project type tab again later EPLAN 5 Basic Training Serial Page Numbering In this numbering type the pages are numbered consecutively The page numbers must lie within the range of 1 to 99 999 In addition to the page number you can specify a subpage consisting of exactly one number or character This is advisable in particular if you have to include additional pages when modifying an existing diagram or a list Examples are LO Ores 24 C DIN Page Numb
21. be wired to a three level terminal 3 levels x 2 screws level x 2 conductors The names usual in trade are also Distributor terminal Shunting terminal Three wire terminal Potential connector etc In EPLAN multi level terminals are defined by using the terminal properties see next chapter The special text 450 Levels is available for the graphics output of multi level terminals into the terminal diagram This allows you to define the level as well as the jumper The following table provides an overview Definition in form Special text Special text 400 Special text 450 450 Not available As before No change to existing outputs Value 0 As before Output of level 0 corresponds to the as numeric standard terminal value Value lt gt 0 All wire jumpers All jumper bars To graduate the circle diameter Same position open circle if more finely the double as before no jumper diameter for the font in relation to the wire jumpers must be selected EPLAN 5 Basic Training Defining Terminal Properties The properties of the terminal are defined in the Symbol properties dialog box That is you determine how EPLAN will evaluate this terminal for display in the terminal diagram Please note that specific fields in the Symbol properties dialog box cannot be displayed or edited when you insert terminals connectors from a single pole symbol file into a schematic page of the X Single pole
22. display type The following input possibilities are available on the Terminal connector pin tab 4 Symbol properties Terminal connector pin Text display Parts Designation BSB ie Connection of the external output position in Form U Below sti i Connection for cable generations U Below O H PLC designation PO Function text PO Symbol number 30 7 Angle variant 0 0 Symbol type 106 eee T Multi level terminal on level fo Terminal stip search directiorr From the left From the top Sorting identifier lo Alohanumerical z Check identifier lo Once Jumper bars 0 Automatic ng EPLAN 5 Basic Training Designation Enter the terminal s device designation here The designation can consist of the higher level assignment location designation terminal number and terminal subnumber You can use the button located next to the Designation field to assign terminal designations system supported Connection of the external output position in form In this entry you define the direction that is considered to be external when viewed from the terminal in the schematic The term external is used to specify a specific location on the terminal diagram form The terminal targets found by the EPLAN search in the specified direction will be entered on the external side position A and C on the terminal diagram Connection for cable generation In this entry yo
23. in the subsequent Selection of the projects to be backed up dialog Use Reset to set the selection back to the project that was originally set in the Project selection dialog box Graphics Symbols in the Project Selection Function The following graphics symbols are used to display the backup mode of a project in the tree view of the selection dialog box Archived projects ye Filed off projects Filed off projects which have been compressed Afterwards the Backup dialog is called up in which you can specify the various backup parameters Also refer to the information on the Backup dialog box Confirm with OK to start the backup action If necessary you will be asked beforehand to insert a backup diskette If the system notices that the backup medium is not empty a message is displayed and you can decide whether you still want to use it for the backup The result of the data backup is documented in the message management and output to a window When you confirm with OK you will be returned to the backup module EPLAN 5 Basic Training lf all your project files do not fit on a single diskette the additional diskettes will be assigned the designation p and be given a sequential number Note the name on the label of the respective diskette Copying Projects for Data Exchange When you copy projects to diskettes for the purposes of exchanging data you should take note of the following points when backing up the project
24. line in the Line data tab see the section on Defining Line Data of Black Boxes and Wirings in the User Guide 4 Symbol properties Ea Cable Text display Line data Parts e pee EE i Line thickness 013 mm Pattern length 1 Value shown as a of the diagonal page size Cancel The extension of an already defined cable line can also be subsequently edited by calling up the pop up menu on the insertion point of the line and activating the Change size option EPLAN 5 Basic Training Parts Data of the Cable Definition Finally enter the part specific information concerning the part number number of units etc in the Part tab Use the Select button here to branch to the parts management function and access the data saved there 4 Symbol properties Ed Cable Text display Line data Parts fat fe en afec aoa aaea o o o o S Delete Select Cancel EPLAN 5 Basic Training Displaying Cable Properties The most important cable properties are displayed if you place the cursor on the insertion point of the cable line right click to call up the pop up menu and select the Display properties menu item 4 Cable information Cable designation EAF 5 1 3 Cable type Olflex 100 HT No of conductors jax Crogs sectior 2 5 Length Voltage Note that the Cable information window is only a display window i e the cable specific data cannot be edited he
25. main menu follow the menu path Utilities gt Parameters gt Project gt Graphics output gt Graphics form tab Enter the name of the desired plot form into the Table of contents field or select the plot form via the button The forms have the extension sxz and are saved in the directory EPLAN4 N The check box in front of the field indicates whether the respective form exists Influencing the Output The output of the table of contents can be controlled via parameters that are located in the Table of contents group box on the Graphics output tab This tab is also offered in the Graphics output parameters dialog box EPLAN 5 Basic Training 4 Graphics output parameters H Numerca a Entire output EPLAN 5 Basic Training The following options are available Create subpages This parameter is important if the table of contents is longer than one page You use it to specify whether subsequent pages will be numbered as subpages or will be sequentially numbered Character for subpages This parameter becomes important if the Create subpages check box was activated You can then specify the numbering style to be used for subpages If subpages have numerical designations EPLAN can manage up to 9 subpages for each primary page In this case the table of contents can have a total of 10 pages for each primary page the primary page itself 9 subpages lf the designations on subpages are alphabetical
26. marked with an asterisk see the highlighted third menu entry in the example If more than 9 working windows or pages are open you can select the More windows option to call up a dialog box in which all open pages are available G Example for the Window menu with several open pages Window wiew Help laj xi Close all Cascade Tile vertically Tile horizontally Arrange icons E 1 EPL5001 Graphics editing 6 2 EPL5001 Graphics editing 7 3 EPLSO01 Graphics editing 11 4 EPLSO01 Graphics editing 1 5 EPLSO01 Graphics editing 13 6 EPLSOO1 Graphics editing 14 7 EPLSOO1 Graphics editing 15 S EPLSO01 Graphics editing 16 9 EPLSO01 Graphics editing 18 More Windows EPLAN 5 Basic Training Closing all Working Windows Project gt Graphics editing output gt Window gt Close all To close all open pages or working windows at one go select the Close all option from the Window menu EPLAN 5 Basic Training 1 Editing Schematics The ability to graphically display devices as symbols is the most important function in the creation of schematics In EPLAN you can only graphically show devices as symbols on logic type pages for example on the Schematic or Single pole page type In the following sections we will explain the multipole display For information on schematics in single pole display please refer to the section entitled Creating schematics in Single pole display x Schematic extract with exampl
27. subdirectories will be referred to as project directories Projects include shared data not stored in the project directory This is information used by all projects and includes macros master and parts data as well as print forms During the installation a directory with your customer code is created in the various directories In order to keep your data separate from other customer specific data you should create additional directories for each customer If you use special macros parts data or print and control forms for customer Smith you should create the following directories for this information EPLAN4 N SMITH For master data EPLAN4 M SMITH For macros EPLAN4 L SMITH For parts data EPLAN4 F SMITH For print and control forms Specifying the Project Type When you create a project you also specify the purpose to which the project is to be used in the project type The following project types are available e Schematic project e Symbol project for editing symbols e Form project for editing plot forms for terminal diagrams interconnect diagrams bills of materials etc e Macro library project for editing macros which are to be used in the Schematics Generator EPLAN 5 Basic Training In EPLAN you will most often use schematic pages However a project can generally be any of the above mentioned project types The project type can also be changed subsequently Thus you can change a schematic project
28. the Cable definition option in the Insert pulldown menu Use the mouse to specify the desired line Enter the corresponding data in the Symbol properties dialog box Finally use the mouse to dynamically specify the text position Input Fields for the Cable Definition Enter the cable specific data for example the cable designation cable type etc in the Cable tab The following fields are available 4 Symbol properties Cable Text display Line data Parts Designation W3 ey ae lomext00H SSCS No of conductors lax E Cross sec tion 25 Length oOo Voltage fo Special cable PE conductor o automatice OO M Shielding o Automatic M Source target lo Sorting terminal diagram I Use for print and graphics output Remark Cance EPLAN 5 Basic Training Designation Enter the cable designation into this field When editing in accordance with DIN you can assign higher level assignments and or location designations by using and as prefixes The cable designation may consist of both numbers and letters If the cable designation does not start with a letter the identifying cable letter defined in the terminal cable specific Cable identifier parameter is used If you do not enter anything in this field the cable designation will be generated automatically for the terminal or interconnect diagram In this case the cable designation will be based on the cable designation defined
29. this file EPLAN 5 Basic Training Editing the Contactor Specification File E Generate gt Contactor selection gt Contactor specification gt Edit Select the Edit option from the Contactor specification pulldown menu EPLAN opens a dialog box in which you can enter the following information 4 Contactor specification Auxiliary contactor with auxiiary Bigg 121704 DLER2 AVEOROHD z component de ozman CS T NOconect SO 2 NC contact SOS 2 NC contact TENO contact r i ENEN LLU LUU CEECEE LUTE EPLAN 5 Basic Training Part number The part number is the key field for the contactor specification file that is EPLAN uses the part number as the search criterion for contactor specifications Therefore each part number must be unique and must be the same as the part number for the corresponding contactor in the master parts file Among other things the master parts file manages information such as coil voltage and contact rating In other words technical data for the contactor If the two numbers do not correspond or if no number has been included in the master parts data the bill of materials cannot be generated correctly Type designation Like the part numbers the type designation must be unique Contactor type Group The identifier in this field specifies the type of contactor in question and the various possible contactor auxiliary block combinations Power contact
30. type The following section provides an overview of the various EPLAN page types EPLAN 5 Basic Training Page Type Overview You determine the page type of a page while creating it We recommend not to change the page type when processing of the page properties later since information may get lost while doing so Whether menu items and functions can be activated in graphics editing depends on the page type For example the insertion of symbols from symbol files is only possible on logic pages schematic pages PLC pages and pages in single pole display Fr The J K L M N O P R S U V page types automatic graphics pages are automatically created by EPLAN Only if you want to edit the forms in a forms project may it be necessary to manually create pages of this type The following page types are available in EPLAN A Schematic schematic pages can access special functions associated with the creation and evaluation of schematics This includes inserting symbols with automatic wire as well as functions taken into account during generation runs for terminal and interconnect diagrams or for cross referencing EPLAN 5 Basic Training Using the Working Window of Graphics Editing The graphics editing module provides a specific window type the working window for drawing schematics The working window also called graphics screen in the documentation are default Windows windows offering the familiar
31. D259 ABE LA SIE KM 1A4 220 01 3TB40 17 0AMO 22 SIE KM 1A G12 01 STBA0 17 0BA4 22 SE KM JA CA O E een eA 1640 17 0B 22 i SIF KM 1A WA 1 ATRAN 17 NARN 2 of Selection parameters Selection f Contactor specification file C 4EPLAN ANFO E SOO0SDED M Use existing contactor designations Use previous run Minimize unused contacts f Number of free contacts permitted Show power contactors Display The three list boxes below show the technical data for the contactor currently set under this DD The window on the left lists the available contacts with the coils indicated before the other elements of the contactor The number of every element within the contactor is displayed Available as well as the number of the already used and the unused elements contained in the schematic EPLAN 5 Basic Training The windows in the middle and on the right show the contact image of the contactor the window in the middle for the elements of the contactor and the window on the right for the elements of an auxiliary block possibly assigned to this contactor The upper two window entries are reserved for the coils and the other entries for the remaining elements of the contactor or auxiliary block In addition to its designation the two connection designations are displayed for each element An element is shown against a gray background in the contact image if it is already used in the schematic In addition a red check mark is di
32. Enter a function text of up to 255 characters for this terminal into this field This text is output in the Function text column of the standard terminal diagram The function text entered here can also be translated online Symbol number This field indicates the internal position of the symbol in the symbol file Click on to change the current selection Angle variant This dropdown list box shows the existing angle variants for the current terminal Angle variant Note that a change of this setting has an influence on autoconnecting Symbol type Enter the symbol type for the terminal here The symbol type is evaluated during the generation of the terminal line up diagram The type is used to differentiate between the individual terminal types You can also launch the Selection of the terminal symbol type dialog box via the button and select the symbol type of the terminal there The section Symbol Type Terminal and Accessories of the System Manual provides an overview of the terminal symbol types Multi level terminal on level If you activate this check box after having entered a normal terminal this terminal is defined as multi level terminal When specifying the level you determine the clamping point in the terminal housing thus the story or level Fr If you select a level gt 1 the Part tab disappears from the terminal properties dialog box EPLAN 5 Basic Training Terminal strip search direct
33. LAN COMPACT the backup management is not included in the backup module but can only be launched by clicking the Undo button of the generation runs You can specify the number of backup copies to be created in the parameter management function under Personal gt Backup param eters gt Number of backups Cleaning up Projects Select Extras gt Clean project to activate the Clean project dialog box used for project maintenance Files that are not needed for the data backup can be removed from the current project through this dialog EPLAN 5 Basic Training 4 Clean project Delete backup pages 455 Delete search databases SUCH Delete data exchange files EF Delete ASCII files ASC Delete page filter SM5 Compress databases Mark all Cancel Furthermore this dialog box contains a function for compressing the databases Using this function the project requires less storage space and is examined at the same time for data consistency Database compression was already discussed under Compressing a project in the section The Backup Dialog Box The backup files backup pages as well as the search databases are also described in the above mentioned section since the deletion of these files can also be carried out in the Backup dialog box see subsection on Deleting files on longer required The following additional files can be removed through the Clean project dialog box Data exchange
34. To customer ns Use the button to launch the Customer selection dialog in which you can select the customers for the To customer field In this dialog box all customers are listed who are stored in the customer master data of the parts management Saving the Defaults of the Backup Settings In order to save the current backup settings as the default values click the Save default setting command button as soon as all the check boxes and radio buttons have been set in accordance with your requirements Whenever you call up the Backup option again these settings are then offered as the defaults Selecting a drive or sending an e mail Using the dropdown list box of the To field you can select the drive on which the data are to be saved If the data are to be sent as e mail the E mail entry must be selected from the list How to send e mails is explained under Sending projects by e mail in the section Editing Projects in this chapter To ja EMail EPLAN 5 Basic Training Backing up and Reloading Data Backing up a Project When backing up projects to diskettes we recommend that you have an adequate number of already formatted diskettes available before you begin the backup procedure Then select the Backup gt Projects menu items in the Data backup module Irrespective of the project you are currently editing it is possible to select any project on the current drive or via the Drives button also on another drive
35. a black box e Without graphics designation lying outside Only a connecting point is specified The wiring ends at this point If you place this terminal inside a black box the connection terminates at the edge of the box The designation of the device end terminal appears outside the black box e Without graphics designation lying inside Same as above but the terminal designation appears inside the black box Connection designation only available on PLC overview pages Using this field you can specify the connection designations or numbers pin numbers of the PLC end terminals on the I O board Connection direction After the Insert gt PLC end terminal or Insert gt Device end terminal function has been selected keep the key pressed down and move the mouse up down right or left to rotate the connection direction The original connection direction is displayed in this field and can be modified EPLAN 5 Basic Training By means of the property dialog box you can not only influence the PLC end terminal properties but also the display of the PLC addresses This is done by using the Text display tab as is the case for general symbols from the symbol file see the section on Defining the Display of the Symbol Texts in this chapter ie Notes To generate a cross reference between schematic page and PLC over view page the address and type of connection connection subtype as well as the device type must be identical
36. aily e Back up projects prior to initiating global processing functions such as numbering and evaluation runs e Back up completed projects e Back up master data such as symbol files after any modification Utilities gt Backup To access the data backup menu first go to the main EPLAN menu then select Utilities and Backup Before describing the various data backup functions we will start by explaining a number of terms used when working with the data backup module Terminology File group Project backup tasks differentiate between project specific and non project specific data master data File groups are stored behind the directories defined for EPLAN and each group contains files associated with specific task steps such as the macros group whose files are located behind the zPLan4 m directory EPLAN 5 Basic Training Documentation Database This database is managed by the EDOC program function and is used to provide an overview of the projects In particular this includes information about when and where a project was backed up filed off or archived For detailed information on EDOC please refer to the section Editing the Project Documentation earlier in this chapter In the subsequent section you will find information on the various data backup functions Defining Default Settings The Backup Dialog Box Backing up and Reloading Data Compressing and Extracting Projects Executing Special Functions of the
37. ain symbolic names This makes it easier to identify PLC connections e g FEEMED2 for Feeder Medium 2 Supplementary field not available on PLC overview pages Use this field to enter general information for the PLC end terminal This information is displayed and plotted if the Show supplementary field parameter is activated under Utilities gt Parameters gt Project gt Graphics Graphics 4 tab The text in this field can be translated online The online translation function see the chapter on Translating Texts Online in the User Guide II is started by pressing the right hand mouse button to call up the Foreign languages pop up menu EPLAN 5 Basic Training Function text not available on PLC overview pages A function description for the PLC end terminal is entered in this field The text you enter here which may contain 255 characters takes precedence over the function text in the same path which you can enter as a Function text text type This information is displayed and plotted if the Show function text project parameter is activated Utilities gt Parameters gt Project gt Graphics gt Graphics 4 tab The function description entered here can also be translated online Terminal display not available on PLC overview pages You can select between the following display modes in this dropdown list box e With graphics A terminal with a connecting point is drawn If required this terminal is also shown in
38. also use the online process to correct any errors found in individual contactors during the off line selection Using Existing Contacts Once you have selected a contactor Contactor selection button in the Symbol properties dialog box for the main coil you can have the unused contacts displayed by clicking on the Reserve contacts button in the Symbol properties for the other contactor elements dialog box and select them with the cursor after having high lighted a contact Contactor data are automatically updated online This means that not only will the part number and type designation be written back to the schematic but all connection designations as well This applies to all pages on which contacts of the contactor being currently edited are located Correcting the Contactor Selection Generate gt Contactor selection gt Contactor gt Correct You can change individual contactor selections at the end of a selection run without having to repeat the selection process for the whole project First activate the Correct menu item A list containing the already selected contactors will be dis played In addition to the DD the part number as well as the type designation are displayed in the list for each contactor In this list you highlight those contactors that are to be corrected it is possible to highlight several contactors at once After having clicked on the OK button change over to the familiar Contactor selection d
39. apter Now insert a PLC end terminal into the black box or the PLC box by following the menu path Insert gt PLC end terminal in the graphics editing module When the terminal has been placed the Symbol properties dialog box is opened In the PLC end terminal tab specify the properties of the inserted terminal which EPLAN requires for generating PLC cross references EPLAN 5 Basic Training Entering Symbol Properties for PLC End Terminals The following entries can be made in the PLC end terminal tab Address Enter the full address of the PLC end terminal here The address usually consists of an identifier which marks the connection as input or output a number for the byte address a separator and a number for the bit address e g 08 4 Output Byte 8 Bit 4 Fr By means of the PLC generator you can edit PLC addresses and write them back to the schematic As an alternative to manual input you can also click the command button to make a system supported address selection EPLAN then displays all the PLC addresses still available in the subsequent PLC address selection window Which entries the selection list contains depends on the respective insertion situation Situation 1 You insert the PLC end terminal into an I O board black box with symbol type 13 which already contains a device designation In this case the list in the selection dialog box only shows the free addresses of the I O board currently edited
40. arget directory if required When doing so the respective base directory e g EPLAN4 m for macros cannot be changed When finished click on OK to return to the data backup module Compressing and Extracting Projects Compressing Projects You can reduce the space requirements of project files by compressing projects This function uses a so called compression program to compress the files Decompressing the files extracts them from the compressed file Fr Please note that you cannot edit compressed projects Select the Backup gt Compress menu items to compress the current project in the current working directory To do this the Clean project dialog box is launched In this dialog you can specify which of the files that are not needed for the data backup can be deleted After the prompt whether the existing backup files are to be deleted the compression process is started EPLAN 5 Basic Training 4 Compress c o The loaded project will now be compressed with the FEZIF ESE compression program in the working directory Delete the existing backup files Cancel Fr In project selection compressed projects are identified by a special graphics symbol 2 as well as by the text Compressed in the project properties Example for the display of a compressed project in the project selection Current project directory C EPLAN4 PATDOC El C H E EPLAN4 P TDOC Ca FORM 2 PLAN H E SYM
41. ata of this cable differ from those of a cable of the same type and this check box is activated the Differing cable data message is suppressed PE conductor Shielding Use the dropdown list box of these fields to specify whether the respective value in the cable type file is to be used or whether you want to specify a different value There are the following selection possibilities e Automatic The definition of the PE conductor shielding is imported from the cable type defined in the Cable type input field e Without Even if the cable defined under Type provides for a shielding or PE conductor it is not created in the interconnect diagram e 1 PE One end If this entry is selected a shielding PE can be generated e 2 PE Both ends Select the 2 PE entry if two PE conductors are to be allowed for the cable If the shielding is connected to both ends this entry suppresses the message Two several shielding conductors intersected Source target Use this entry to specify whether the target designations in the interconnect diagram should correspond to those of the terminal diagram or whether the target designations are to be exchanged Use for print and graphics output If you activate this check box EPLAN will consider the cable specified here and includes it in the printout as well as in the graphics output of the interconnect diagram This is the default setting If the check box is deactivated the cable is ignored during o
42. dit Selection Directories Delete Copy Gave Cancel Fr Please note that the availability of the functions depends on whether you have selected a directory or a project and if you are currently editing the project properties EPLAN 5 Basic Training Function New Rename Copy Delete Edit Save Drives Action Create a project directory This option can always be activated Depending on the subsequent option you select either a new project is created in the corresponding sub directory or a new subdirectory is created Rename projects directories Using this function you can rename the project or directory currently highlighted in the directory tree Copy projects Activate this option and enter the drive path and name of the project to be created in the subsequent dialog box Delete projects directories Use this functions to delete projects or empty directories A prompt for confirmation is displayed when you select this option Edit projects This function is used to edit the project properties of the currently selected project Save projects Use this function to save the project properties you entered The corresponding button or menu option is activated when a new project is created when projects are copied or when project properties are edited Change the drive for the project selection Use this function to have all drives displayed in the directory tree that contain EPLAN pr
43. e HLA 1 LOD 1 1 HLA 1 LOD 1 2 At the type Higher level assignment and location designation at least one of the three identifiers higher level assignment location designation page number must identify the page uniquely The higher level assignment is unique in the following example HLA 1 LOD 1 1 HLA 2 LOD 1 1 At the type Only location designation at least one of the two identifiers location designation page number must identify the page uniquely The location designation is unique in the following example RT HOW Uy Al LOD A a At the type Higher level assignment only at least one of the two identifiers higher level assignment page number must identify the page uniquely The page number is unique in the following example HLA 1 1 HLA 1 2 EPLAN 5 Basic Training Page Numbering according to KKS Page numbering to the German KKS for numbering power stations is carried out using the higher level assignment and location designation These identifiers are preceded by one identifier each for the document type and the documentation type A page designation to KKS thus consists of Document type Documentation type Higher level assignment if appropriate subpage Location designation if appropriate subpage Page number if appropriate subpage Ensure that the page designations differ by at least one identifier The following expressions are thus valid page designations to
44. e Phoenix Contact GmbH amp Co OLFLEX OLFLEX SERVO and OLFLEX CLASSIC are registered trademarks of the U I LAPP GmbH AutoCAD and Volo View Express are registered trademarks of Autodesk Inc SIMATIC HW Config is a registered trademark of Siemens AG SCAN is a registered trademark of McAfee Associates PKZIP PKUNZIP are registered trademarks of PKWARE Inc ObjectStore is a registered trademark of eXelon Corporation D ISAM is a registered trademark of Informix Software Inc Hardlock E Y E is a registered trademark of Aladdin Knowledge Systems Ltd Int InstallShield is a registered trademark of InstallShield Inc PMS is a registered trademark of PMS Compelec GmbH MicroStation is a registered trademark of Bentley Systems All other mentioned product names trade names and company names are trademarks or registered trademarks of their respective owners Note The hardware requirements indicated by the operating system manufacturers must be considered Hardware combinations that according to the manufacturer s specification cause malfunctions may also have an effect on the operation of EPLAN LOGOCAD TRIGA Therefore an accurate basic installation of hardware operating system and hardware drivers e g graphics board driver etc is essential for a smooth operation of EPLAN LOGOCAD TRIGA Therefore the main conditions and areas of application specified by the hardware manufacturers also apply to the opera
45. e generated in a procedure analogous to that for contact cross references Simply select Generate gt Generate in the cross reference module and activate the Interruption point cross reference check box in the subsequent dialog box Here too a checkmark in the Run carried out field indicates that you have already generated interruption point cross references at an earlier point in time Once you confirm the dialog box by clicking OK EPLAN starts the interruption point cross reference run If interruption point cross reference errors occur in the project EPLAN outputs messages during the evaluation Generating Cross references according to IEC 1082 1 Up to now a cross reference has in general been represented by a page and a path specification separated by a specific character The so called path specification is the subdivision of a schematic page into several columns marked by a number or a letter In many cases an additional subdivision in line areas is required This requirement is based on the IEC 1082 1 standard which corresponds to the EN 61082 1 standard and which is supported by EPLAN as from version 5 50 EPLAN now adds one letter to the cross reference which is placed ahead of the path specification This letter specifies the line area of the counter element EPLAN 5 Basic Training In order to determine the line area the current page is subdivided into equal sections The line sections are designated with ascendi
46. ecific search results which are written into the search database during certain actions are to be deleted Compressing a Project You can use the radio buttons in this group box to compress your project during the data backup Compress project beforehand C Yes ie Ho This compression is a completely separate action from the project compression function and is performed by a separate EPLAN module which reorganizes the project database The function irretrievably removes any deleted pages from the project and removes gaps in the database The project can be examined at the same time for data consistency In addition you can continue to edit a compressed project with the standard EPLAN graphics functions Only the deleted pages can no longer be accessed Fr The database compression can be started in the EPLAN main menu by selecting Project gt Compress page database The section on Revising the Page Database in this documentation will provide you with further information on this topic Backing up General Type Files If you have used general not project specific cable and connector type files in your project you can use the two check boxes in this area to specify whether these are to be backed up with the project data IF project specific files do not exist T Copy cable type file to project T Copy connector type file to project EPLAN 5 Basic Training Backing up Associated Files When you back up projects you can als
47. ectory all files except for the backup files and the error files are backed up EPLAN 5 Basic Training The Backup Dialog Box The Backup dialog is called up when you have selected a project and wish to save it or to send it by e mail or when you wish to save non project specific data such as macros Backup number for EDUC fe 1 PO Number of media Stored at Backup method C File off for external processing Archive back up and delete Backup type According to control file All files in the directory C Selected files see Help individual selection Delete databases Number of media Backup files Backup pages 7 455 Search databases Compress project beforehand i Yes ie Ho f proyject specitic files do not esist Stored at Humber of media Stored at T Copy cable type file to project T Copy connector type file to project Projact speciic files C No backup Backup Backup with print forms Save default setting To la Removable mediurr Cancel The various options of this dialog box will be explained below Depending on the backup selected you do not always have all options available EPLAN 5 Basic Training Specifying the Backup Method There are three backup methods available Backup Backing up copies the project to the target data medium In other words the project remains available in exactly the same form File off
48. ed after the period The following assignments apply Projects Master data Macros Parts data Print and control forms Personal and workstation parameters oOonr gaz uU Each control sequence line is followed by one or more lines containing file specifications The use of the wildcard characters and is allowed in accord ance with standard DOS conventions means that all the files of the directory are to be backed up Example of a patsicu INF file e Project directory seiten Graphics database projekt ppd Project parameter file ort DIN file of location designations anlage DIN file of higher level assignments N Directory for master data x all files M Macro directory ESS D MSF Page macros graphics pages T Parts directory k x all files F Directory for print and control forms EPLAN All EPLAN form files EPPS All ERP form files O Personal and workstation directories a8 all files EPLAN 5 Basic Training Files specified with a preceding will not be backed up All other listed files will be backed up lf a colon is used for the identification only the combinations of a colon with the file name or with the file extension are allowed Examples of the identification with a colon for an extract from another DATSICH INF file P Project directory pDackup e g backup spl rE g Ep10004 err x M Macro directory This means that in the project dir
49. eload menu of the Data backup module Utilities gt Backup gt Reload gt Projects If necessary you will be asked to insert a diskette After project selection in a subsequent dialog box you can decide while reloading projects whether the project is to be reloaded under its original name or whether you want to assign a new name 4 Directory New project name FUE PLAMPROJECTA Cancel If you confirm the original name the project files are written back to the original directory If you enter a project name that already exists or confirm of the original name a window appears asking you if you want the project directory to be overwritten When reloading projects for which project associated files were backed up as well you will we prompted in subsequent dialog boxes how to proceed with the associated files The reloading result is documented in the message management and output to a window Click OK to return to the data backup module EPLAN 5 Basic Training Specifying Directories for Shared Data When reloading projects an additional dialog box is called up once the project name has been specified The Specify directories dialog box only appears for projects for which the project specific files were included in the backup Enter the directories manually here or use the buttons that will open a selection dialog box 4 Determine directories Directory structure Project related C Cu
50. en power contact in the schematic EPLAN will look for a contactor with an SL contact with symbol type 0 in the contactor specification file If you have not specified a contactor with this contact in the specification file EPLAN cannot find a matching contactor Note that while the symbol S normally open and symbol type 0 also represent a normally open power contact this designation is not the same as SL and 0 Therefore ensure that you only enter valid symbol names when entering them manually and that you adapt the symbol type of the contact EPLAN 5 Basic Training Symbol type In the Symbol type column you can have the symbol types of the entered coils and contacts displayed and check them Fr If a specific contact is to remain free assign the first entry blank entry from the dropdown list box to it Contact 1 H Hl Contact 2 f at a ET RET A Oe ee a ee SE Saree 2 E Normally closed contact 07 02 03 ONE Break contact which is late to open O 04 D Contact OOY Normally clased on delay 07 05 03 Contacts OS Normally closed off delay 07 05 04 JOT Normally closed thermal trip 07 09 03 LontactS OVE Break contact which is early ta open O7 04 E ai The individual command buttons of the dialog have the following effect New This function lets you re create contactor specifications The data of the contactor last selected are retained as default values and can be revised Change
51. ering In the case of DIN projects the page designation can include a higher level assignment a location designation or both depending on the numbering type selected EPLAN provides the following numbering types for the resultant combination possibilities Higher level assignment and describing location designation Higher level assignment and location designation Location designation only Higher level assignment only The two upper types differ only in as far as a local designation specified at the type Higher level assignment and describing location designation is not used to identify a page Only the higher level assignment is used In the second type Higher level assignment and location designation both identifiers are used for identification In the other types the respective identifier used exclusively Location designation only or Higher level assignment only serves to identify a page EPLAN 5 Basic Training Sequence of the Identifiers As a rule the individual identifiers are to be used in the following order for a page designation to DIN e Higher level assignment if appropriate subpage e Location designation if appropriate subpage e Page number if appropriate subpage At the type Higher level assignment and describing location designation at least one of the two identifiers higher level assignment page number must identify the page uniquely The page number is unique in the following exampl
52. es for the display of devices 13 be E4 aMi ja E42T LS A K43M Na Terminology The following terms are particularly important when working with symbols and devices Symbols device designations Electrical and mechanical devices are represented by graphics symbols in EPLAN A device in the project is identified by EPLAN by means of the device designation DD you always have to specify in order to receive error free evaluations Symbol files EPLAN manages most symbols in symbol libraries the so called symbol files You can extend or edit them Apart from the symbols you can insert from symbol files into the schematic there are symbols that are not linked to a symbol file for example the black box the interruption point or the device end terminal Symbol properties When inserting a symbol into the schematic EPLAN opens a dialog box into which ePLAN 5 EPLAN 5 Basic Training you must enter symbol specific texts or identifiers These data are called symbol properties EPLAN evaluates the symbol properties during the various generation runs One of the most important symbol properties is the device designation Depending on the symbol you insert into the schematic EPLAN displays various fields for inserting symbol properties Wires If the connecting points for device symbols lie opposite one another either vertically or horizontally connections between the symbols are generated automatically autoconnect
53. files xF When exporting a project to the data exchange format EXF the entire project is converted to a file This file that by default is called EPL_asc ExT and is stored in the project directory can therefore become quite large and should be removed before the data backup is carried out ASCII files asc Through the corresponding check box ASCII files that may have been created in different ways are removed from the project directory Page filter sns A page filter file is created in the project directory if a page selection is permanently saved in graphics editing To clean the project activate the corresponding check boxes and confirm with OK If all functions are to be carried out click the Mark all button first and then click OK
54. functions such as Move Minimize etc In contrast to the two other window types page overview message window in graphics editing it can only be placed within the main window A working window shows the graphics contents of an open page If you have modified an open page EPLAN displays an asterisk in the title bar of the working window to indicate this Example of the title bar of a modified page EPL5001 Graphics editing AP 5T1 13 EPLAN allows you to view several pages at the same time on the screen For this purpose you Can open several working windows see the section on Opening pages in a new window in this User Guide Even if several working windows are open at the same time pages can be edited in only one window at a time The window containing the page in which the current cursor movements and functions are carried out is called the active window You can recognize this window by its colored title bar EPLAN 5 Basic Training Switching between Several Open Working Windows If you want to change from one working window to another open working window simply click on it In addition the cm cam key combination can be used for this purpose Project gt Graphics editing output gt Window It is also possible to select the desired window via the Window menu All open working windows are listed in this menu The active topmost window is marked by a preceding checkmark Y In this list a modified page is
55. fy the name of a general contactor list by either entering it in the text field under General or by using the button Enter a new file name here in order to create a new general contactor list EPLAN 5 Basic Training You define a contactor list by highlighting data of the contactor specification file in the left hand area of the dialog box and then copying them to the area on the right hand side with a click on the button You can also delete elements from a contactor list by highlighting them in list box in the right hand half of the dialog box and then clicking the button By activating the Preview check box you can have the contact image for the currently highlighted contactor displayed By clicking on Apply the selected contactors are saved in the respective contactor list In contrast to the OK button the window will not be closed so that you can select and copy additional contactors or undo the selection Defining Contactors This section describes the structure of the contactor specification file how you can add and modify contactor specifications and how to import export the contactor specification data Entries in the contactor specification file are arranged by part number These part numbers should conform to the part numbers of the corresponding contactors in the master parts file or in the tpt file depending on the parts management used so that EPLAN can load the technical data for the contactor from
56. hematic EPLAN 5 Basic Training Defining Shieldings The Shieldings function lets you add the graphics symbol for the shielding of wirings You can use the mouse to define the size of the shielding You must activate this function next to the wires for which you want to add a shielding You can use the mouse to expand and rotate the shielding as required Shieldings can also be created by clicking the button of the Insert toolbar The designation for shieldings entered in the terminal and cable parameters menu path Utilities gt Parameters gt Project gt Terminals cables is evaluated in the terminal or interconnect diagram as the target designation 4 Parameters to create terminal and interconnect diagrams Terminals cables 1 Terminals cables 2 Terminal subdivision D x 4 0 i 4 l Shielding target designation Sh Conductor designation for shielding SH In order to subsequently change the width or height of the shielding position the cursor on the shielding s insertion point and press or the left mouse button You can then use the mouse to dynamically change the size To modify the graphics data of a shielding right click on the insertion point of a shielding to call up the pop up menu and select the Attachment line type option Afterwards left click on the insertion point of the shielding and modify the current data for line type line thickness and pattern length EPLAN 5 Basic Tra
57. ialog in which you can repeat the contactor selection Fr Note that direct assignment of the part number without a check is only possible in the graphic when you input the symbol EPLAN 5 Basic Training Setting Parameters for the Contactor Data Output E Utilities gt Parameters gt Project gt Contactor cross reference wiring On the Contactor 2 tab you can specify the parameters that influence the output of the part numbers and of the type designations of the contactors in the schematic You can access the parameters either from the contactor selection module or via the parameter management function 4 Parameters for contactor selection and the cross reference program Centered E T Abe E 1213mm E T centered E EPLAN 5 Basic Training These parameters include Output identifier By entering 1 or 2 you can have the part numbers and the type designations output above or below the contact image in the schematic If O is specified no number will be output Output auxiliary block If you activate the check box the auxiliary block will be output in addition to the part numbers and type designations In order for this to occur you must have specified either a 1 or 2 in the Part no output identifier field Font size Use the dropdown list box to specify the font size in which the part numbers and type designations of the contactors will be displayed in the schematic Alignment Here again
58. ies for the compression the Directory selection dialog box comes up Select the Project related setting here to backup the correct directories during the compression Compress Sen Sha d by e mail MW JSE EPLAN 5 Basic Training Executing Special Functions of the Data Backup Reloading the Backup The Reload backup dialog shows a list of the last backup copies of the entire project The display contains the user date time and the executed function To retrieve a backup copy highlight the corresponding line in the dialog box Then click on the OK command button The process is started and the dialog box closed lf you wish to delete a copy click on the Delete command button after having highlighted the corresponding line The Reload backup dialog box can be called up as follows e Inthe data backup module via the menu path Extras gt Backup management e In the cross reference module and in the terminal and interconnect diagram module by following the same menu path e Inthe Move Number and Position functions of the generation runs by using the Undo button In order to undo changes it is possible to create a backup copy for the project before executing the Correction function Move Number and Position functions To do this the Create backup check box must be activated before carrying out the respective function A backup is also generated when the page database is compressed ye Notes In EP
59. in the terminal cable parameters The cable designation can also be assigned with the support of the system For detailed information refer to the following section System supported Assignment of Cable Designations Type The cable type defines what kind of cable is being used This is important when assigning color codes and when the maximum number of conductors is considered If color codes are to be assigned or if there is a maximum conductor number the cable file must have an entry containing the name specified here and the corresponding data Use to access the data already created No of conductors lf the form used contains a corresponding entry the number of conductors entered here will be imported into the terminal and interconnect diagrams Enter the number first You can then enter an x as a separator between the number of conductors and the cross section You must enter this x if you are using the standard forms supplied by EPLAN Software amp Service In order to specify conductor pairs you can enter a second x If you do not want to use the unit of measure for the cross section that is specified in the parameters enter the x separator as a capital letter The number of conductors specified for the respective cable type can be viewed and applied by clicking on The x separator is then added automatically by EPLAN EPLAN 5 Basic Training 4 Selection of the no of conductors CXE PLAN4
60. ing Angles and nodes are used to branch and divide wires You can use interruption points to continue a wire over a number of pages of the schematic Texts and hyperlinks In addition to devices and wirings it is also possible to insert special objects such as texts and hyperlinks into the schematic in order to get a documentation that is structured more clearly and to obtain additional information A hyperlink is a text inserted in the schematic providing a link to a document EPLAN 5 Basic Training Using Macros Macros are used in EPLAN to facilitate your work as is the case in other programs You can combine several steps such as the insertion of various components and schematic elements with the assignment of device designations to one step that is save as a macro and insert at a later point In general macros consist of any sections of schematic or graphics pages in EPLAN or include the entire contents of a whole project page Furthermore there are various other macros which provide specific functions The following sections first introduce these various macro types Then further sections will follow dealing with the following subjects e Defining a new macro e Using macros Finally you will be familiarized with a specialized application of macros the schematics Generator With the Schematics Generator you can use standardized macros to create your plant documentation without any drawing effort Macro types I
61. ing been made able to be cross referenced Symbol Cross references General symbols can have a cross reference assigned during schematic editing can be made able to be cross referenced This is the only case in which two symbols graphics symbols can have the same device designation The connections on the symbols representing the device connections must have different connection designations In symbol cross referencing the individual symbols are identified as having a main and one or more auxiliary elements The settings required for this can be specified in the Symbol properties input window that you call up in the Symbol type dropdown list Depending on the symbol type this list may contain different elements Symbol type 153 Auxiliary element 50 Main coll 51 Secondary coll 150 Main element lt 153 Auxiliary element 151 Cross reference under symbol motor overload switch 152 Cross reference next ta symbol motor overload switch 154 Cross reference under symbol SU motor overload switch 255 Standard symbol not cross referenceable 254 Graphic element EPLAN 5 Basic Training The following table lists the possible identifiers for the symbol type of the main and auxiliary elements Symbol type Identifier Standard symbol not cross referenceable Symbol as main element cross referenceable 150 Symbol as auxiliary element cross referenceable You can only enter part specific
62. ining Creating a Table of Contents EPLAN allows you to enter page specific information for example for the page designation or the supplementary page fields on every page of your project The function for the table of contents creation is used to read out these data and present them in the form of separate overview pages Extract from a table of contents d Ly D O 0 mt D ct LW Page Page designation DOUKU 4 title sheet UUKUS 2 Table of contents DUKUS 2 1 Table of contents UOUKUS 2 2 Table of contents QOKU 3 EPLAN News 45 50 HP 0 4 plant overview HP 0 2 plant overview HP S71 1 supply HP 571 2 drive HP S741 3 control voltage AP4 S57T1 4 control voltage The next sections will provide information on the following topics Setting Graphics Output Parameters for the Table of Contents Creating a Table of Contents Updating a Table of Contents Editing Special Text Coordinates in the Table of Contents Form EPLAN 5 Basic Training Setting Graphics Output Parameters for the Table of Contents Various graphics output parameters allow you to adapt the format and the type of output of the table of contents to suit your requirements The following options are available Using a Plot Form To output the table of contents in project pages you must specify a corresponding plot form using which you can influence the format of the table of contents Starting from the EPLAN
63. ion Use the appropriate identifier to enter the direction in which EPLAN should search to find the strip designation for this terminal Sorting identifier Use this identifier to specify how the terminal is to be sorted into the terminal diagram You can open the Terminal positioning dialog box via the button where the position of the terminal on the associated strip can be changed Check identifier Use this identifier to specify whether the terminal may occur only once or several times in the terminal diagram Jumper bars By entering the appropriate identifier in this field you can specify whether you want to define jumper bars for this terminal regardless of the automatic evaluation The possible entries can be selected from the dropdown list box In addition to the terminal properties you can specify the display of the terminal number or of the terminal strip designation in the properties dialog box This is done by using the Text display tab as is the case for general symbols from the symbol file see the section on Defining the Display of the Symbol Texts in this chapter Assigning Terminal Connector Designations System supported Just like device designations terminal or connector designations can be assigned system supported too To do so highlight the terminal or connector of any strip in the schematic or insert a new terminal or connector into an existing strip EPLAN 5 Basic Training Afterwards c
64. lick on the button located next to the Designation field in the Symbol properties dialog box for terminals or connectors Terminal Connector pin tab The Terminal selection dialog box that comes up provides an overview of all terminal designations connector designations used in the project for the terminal strip connector strip highlighted in the schematic or to which you have added a terminal connector in the schematic Entries in round brackets signify that the corresponding terminal connector is actually used in the project Entries without brackets indicate spare terminals or spare connectors If you activate the Supplementary data check box the cross reference data and connection targets for each terminal strip connector strip that has been assigned are displayed in the lower window Click on Strip to open the Strip selection dialog box which gives an overview of all terminal strips connector strips used in the project Here you can select the strip which you wish to assign to the inserted terminal connector If you click the Next button EPLAN will automatically suggest the next available terminal number strip number Confirm the suggested designation by clicking OK it is then entered into the Designation field of the Symbol properties dialog box Finally click OK again and the new terminal connector designation is read into the schematic Fr You should already have generated a terminal diagram beforehand in order to e
65. ms EPLAN reads the project schematic pages starts a selection run based on the parameter settings for each contactor it finds and presents the part numbers and type designations of the appropriate contactors or the appropriate combinations of auxiliary blocks in the Contactor selection window Fr It may occasionally occur that EPLAN cannot find a suitable contactor mainly if only a project specific or general contactor list is used EPLAN then asks if the search should be continued suggests all the Suitable contactors from the contactor specification file and changes the selection run to the specified selection file for the next contactor 5 EPLAN No contactor was found in the project specitic or general contactor list f Search in contactor specification file Abort selection for this Contactor The DD dropdown list box in the upper area of the Contactor selection dialog box lists all the DDs contained in the schematic The number of the currently highlighted DD is displayed in the Contactor text box under From you will find the number of DDs this however only applies to the off line selection EPLAN 5 Basic Training 4 Contactor selection x DD l ICO 0RT2 ES Contactor 3 From li 0 Contact image Coil voltage 24 i Contact rating an Part number auxiliary Type designation Typ LF1 D253 465 LA1 D13465 LF1 D253 465 LA LF1 D253 465 LA1 D22A85 LP1 D253 AB5 LA LP1 D259 ABE LA1 D22A85 LP1
66. n EPLAN you can use six basic macro types and three special macro types The basic macro types are Macro type Character Schematic Graphics Page macro SKK a a a a PLC macro Path macro l Variable macro OO yY fJ o o S xX o o Combined macro O Z J o xX EPLAN 5 Basic Training Every macro is saved in a separate file in the directory which you set for saving macros in the parameter management module The extension of a macro file name provides information on the type and possible uses of the macro e The first character of the extension is always m for macro e The second character specifies the macro type this is the Character column in the table e The third character of the extension specifies the page type on which the macro is to be inserted for schematics pages and F for graphics pages The table columns Schematic and Graphics indicate whether a certain macro type is suitable for the respective page type Not every type of macro can be created and inserted on every type of page In addition to the specified types there are further special macro types for which the above rule on the file extension does not apply Macro type Extension Schematic Graphics Plotframe SK Symbol macro a Control panel macro Rittal control panel macro a E E Symbol Macros A symbol macro combines several individual symbols which represent a unit into one object Symbol macros are intended as a sup
67. ncerning data backup is recorded If in addition you have also activated the logging function the data backup procedures will also be recorded in the log EPLAN 5 Basic Training The fields in the right hand area of the Backup dialog box have the following meaning Backup number for EDO e DS Sep 396 08 29 24 4 Diskette 34 1 44 MB Number of media Stored at Humber of media Stored at Backup number You can document up to three backup processes for each project Each backup action is given a number You can enter this number in the input window that appears when you initiate a data backup The entry associated with the number you input is replaced in the documentation database Backup medium The backup medium on which backing up is to be carried out is entered in this field The possible entries can be selected from the dropdown list box Number of media Use this field to enter the number of media needed Stored at You can enter the storage location of the medium into this field e g Project archive Data safe Personal archive In addition the data and time at which the backup was carried out are entered in the documentation database EPLAN 5 Basic Training Filing off Projects lf you have activated the File off for external processing radio button under Backup method you can enter the corresponding information for the project in the File off group box File off
68. nclude master parts files Print control forms These are terminal cable potential forms and contactor lists as well as the forms for the system specific parts management program Plot forms are located in the master data directory In addition this dialog box displays the directories for e Personal and workstation data e Temporary data These two settings serve for checking purposes and cannot be changed In all fields you can right click to launch the pop up menu and to assign the standard entry to the respective field EPLAN 5 Basic Training 4 Input directories for programs projects macros and files EPLAN directories EAP settings Directories Projects p DAEPLANAPESSPLAN Master data MID EPLANAMMESSIES m Macros MW IDAEPLANMAIMESS ES Parts data Jw DAEPLANALESSIEN sd pe Print control forms WV DAEPLANAPRES SE O a Personal workstation data P Derme e Temporary data M CAWINNT PRe a Paste Delete Select all Set default cancel a Use the command button in order to branch to the Directory selection dialog box and to select the directory interactively lf you enter a directory that does not yet exist manually the program will prompt you if you want to create it now The check boxes before the directory entries indicate whether the respective directory exists or not Fr When specifying the directories ensure that they are positioned within the
69. ng letters A F The count ing direction is from top to bottom A specific plot frame is required to subdivide the schematic page into line areas For this reason the EPLAN installation includes the plot frame Esscoo4p sxe for the cross reference display according to ICE 1082 1 EPLAN 5 Basic Training The line division is carried out in the project specific graphics parameters by making an entry in the Line size input field For detailed information on this parameter refer to the section The Parameters on the Graphics 1 Tab User Guide II i Notes The path and line specifications contained in the cross reference do not have an additional separator The specified cross reference format applies to the schematic as well as to all cross reference specifications in databases or on generated pages There isn t an offset for the desired subdivision The subdivision starts at the upper zero point and goes to the lower end of the sheet The beginning of the sheet upper zero point is the top edge of the plot frame The bottom edge of the plot frame represents the lower end of the sheet EPLAN 5 Basic Training Contactor Selection Selecting Contactors Off line For off line selection start the procedure after the schematic has been completed This lets you select all contactors in the entire project in one pass Generate gt Contactor selection gt Contactor gt Select Select the Contactor gt Select menu ite
70. nia DEMO_D ha MICKLAS Extracting Projects lf you select a compressed project for graphics editing EPLAN points this out and offers to extract it in a subsequent dialog box As an alternative the decompression can also be directly started via the Reload gt Decompress menu items of the Data backup module EPLAN 5 Basic Training Please note that in case you decompress data that were packed by the ARJ compression program in an earlier EPLAN version prior to EPLAN 5 50 you must certain workstation specific parameter If this is the case specify the directory in which the ARJ compression program is loaded in the input and output parameters As an alternative the directory can also be determined by a corresponding entry in seta the PATH system variable Control Panel LF Mer H Fename Copy Delete Edit Save Update Drives Selection Notes Projects can also be compressed and extracted within the project management To do this select the Select create copy project option under the Project menu item to call up project management Highlight the desired project s in the directory tree and select the respective Compress or Decompress menu item from the pop up menu Unlike the process in the data backup module the Compress or Decompress queries will not appear but the projects will be compressed or extracted immediately If the project specific directories do not correspond to the current director
71. ning In the following sections you will find detailed information on the topics Generating cross references Creating wiring lists Updating the text database and checking function texts Creating and deleting wire numberings Automatically correcting cross reference errors in the schematic Creating a list of special components Deleting cross reference databases Editing cross reference data Outputting formatted cross references Deleting the contactor contact arrangement in the schematic Outputting wiring lists as graphics pages Evaluating messages produced during cross reference generation Setting parameters for the cross reference display and output Online cross references when copying schematic pages Online updating of cross references when renaming and deleting schematic pages Generating cross references EPLAN produces two types of cross references in the schematic Contact cross references Interruption point cross references EPLAN 5 Basic Training The program automatically online inserts both cross references into the schematic while the project is being edited Nevertheless we advise you to update the contact and interruption point cross references with a generation run This is of particular importance if e Cross reference changes result from loading macros and the individual symbols interruption points have not been confirmed with in the graphics editing module e You have modified page numbers path numbers
72. nsure that the terminal database has been updated and is error free EPLAN 5 Basic Training Insert PLC End Terminals PLC end terminals are used to display the circuit of sensor or actuator components at PLC assemblies in the schematic In EPLAN PLC end terminals are used on pages of the page type Q PLC page as well as on pages of the page type T PLC overview Insert PLC end terminals on pages of the Q type to realize the byte wise connection assignment of PLC inputs and outputs of an I O board This is different for page of the I type you will need them here to create a board oriented complete overview of the connection assignment of all PLC input or output boards Fr In EPLAN COMPACT you can also insert PLC end terminals in project pages of the type Q PLC page that have been created with the full version However due to the limited functions compared to the full version EPLAN COMPACT does not allow to evaluate PLC end terminals during generation runs In general you must insert PLC end terminals into a black box to make PLC assignments visible on T or Q pages On PLC overview pages this black box is inserted as PLC box Fr Note that after having inserted the black box into a PLC page you must set the symbol number to 13 I O boards in the Symbol properties dialog box For detailed information on how you insert black boxes into the schematic in EPLAN refer to the section Inserting Black Boxes in this ch
73. o include certain files from other file groups in the project These files are required to display a project These include symbol files combined and variable drawing macros and forms for terminal diagrams interconnect diagrams etc The following possibilities are available Project specitic tles C No backup f Backup C Backup with print forms No backup The associated files will not be backed up Select this option if you have already separately backed up the other file groups Backup The associated files from the N Master data and M Macros file groups are backed up Their names are read from the project parameters symbol files plot forms and the project pages symbol macros Select this option if you want to send a project to another EPLAN user e g to allow him to edit it Backup with print forms This option will include all the print forms used in the project as defined in the parameters together with the master data and the project macros Updating the Documentation Database In order to update the information in the documentation database after a data backup you must create a log and activate the log function as well as create an EDOC database before the projects are backed up and reloaded Backing up data also has an effect on the documentation database since for example archiving projects must be recorded in this database The database contains input fields for projects in which specific information co
74. ojects You can then change the drive for the project selection EPLAN 5 Basic Training Function Directories Selection Compress send by e mail Show user Action Change directories Use this function to influence the access to macros master and parts data as well as the print and controls form for the currently opened project This option is only available as a button Select projects delete selection criteria Select the Create submenu option from the Selection menu item if you want to preselect projects for the directory tree Select the Selection gt Delete menu items to remove the specified selection criteria again Compress projects This function is used to compress the currently selected project Send projects by e mail Select this option from the pop up menu in order to send the selected project by e mail If you select this function you will get the information which users are currently editing the project selected in the project management Please note that the Show user function is part of an add on module Only when the license for the module has been purchased can you carry out this function EPLAN 5 Basic Training Projects and Directories EPLAN files projects in the EPLaN4 pP directory which is created when you install the program This directory cannot be altered You can however create subdirectories under this directory in order to make project management easier These
75. ong false target wiring EPLAN 5 Basic Training Target Tracking along Interruption Points Target tracking along interruption points is important for the following functions e Display of the counter target You can use parameters to change the information at the interruption point Among other things you can also have the counter target displayed Graphics parameters Graphics 1 Graphics 2 Graphics 3 Graphics 4 Graphics 5 Font size 1 Schematic logic F Display interruption point designation e Determination of the wiring target If a wire between interruption points leads to another schematic page the relationship between targets must be determined in order for the wiring list to be generated e Determination of the terminal targets If an interruption point is connected to a terminal the interruption point s counter target will be entered as the target during the evaluation of the terminal data Identifier for the Interruption Point Check Use the Identifier for interruption point check parameter to specify what kind of interruption point check EPLAN is to carry out during the cross reference run The individual options are explained in detail in the chapter entitled Setting Parameters for the Cross references EPLAN 5 Basic Training Starting an Interruption Point Cross reference Run Generate gt Cross references wiring list gt Generate gt Generate Interruption point cross references ar
76. or Power contactor with auxiliary black Auxiliary block Any three alphanumerical characters can be entered for the group This way you divide the contactors into groups so that you can define possible combinations of contactors and auxiliary blocks The following contactors were entered in a contactor specification file EPLAN 5 Basic Training Part No Contactor type Group Explanation AAA Aux contactor X Auxiliary contactor onto which aux block an auxiliary block can be added If the number of contacts is insufficient this contactor is displayed together with the auxiliary block DDD for selection grouping X BBB Aux contactor Y As for AAA but can be aux block combined with the auxiliary blocks EEE and FFF CCC Auxiliary contactor This contactor cannot be combined Grouping is therefore not possible DDD Auxiliary block EEE Auxiliary block FFF Auxiliary block lt lt X Part type Use this field to specify the part type under which the contactor or relay will be managed in the master parts data You can define the part as either an individual part I or as an assembly A Variation This field is used to define multifunction relays Since these relays are all listed under the same part number but can have a variety of contact configurations this field is used to differentiate between the individual variants so that EPLAN can also include multifunction relays in the contactor selection p
77. p format e Compression program directory EPLAN 5 Basic Training 4 Parameters to backup files x Input Output Data exchange drive x Network drive Compress W Compress data Use old backup format Compression program directory i ID PACKE ie Notes You can also specify the workstation specific input and output parameters in the parameter management under Workstation I O parameters lf you carry out the data backup with the COMPACT version a compression of the data is not carried out via the internal compression program even if the Compress data check box is activated For further information on these parameters refer to the section Specifying I O Parameters in this User Guide Editing the Control File DATSICH INF In order to specify the extent of the backup you can the edit the control file DATSICH INF in the customer specific directory for the master data Use the menu items Extras gt Edit control file in the Data backup dialog box This function allows you to define the extent of backup separately for each data group Utilities gt Backup gt Extras gt Edit control file EPLAN 5 Basic Training The control file is an ASCII file that must be built up on a line by line basis Each line contains either a file specification or a control sequence All control sequences must begin with a period and define the respective file group The respective file group character is enter
78. plement to the symbol files They are saved with the mys file extension Utilities gt Parameters gt Personal gt Graphics If you use the personal parameter Symbol macros directory you can specify that symbol macros are not to be filed below the directory n for master data but rather below the actual macro directory m For saving symbol macros we recommend to file them in a directory that is named after the used symbol file in order to have a good overview x EPLAN4 N lt customer code gt DIC WUP lt X gt M3 MYS EPLAN 5 Basic Training Generating Cross references and Associated Lists Generate gt Cross references wiring list In this chapter you will learn how to update cross reference data with various generation runs and how to carry out several other functions The respective module is accessed by selecting the menu path Generate gt Cross references wiring list from the main menu Select Generate gt Generate to open a selection dialog box Here you can decide whether you want to start the listed generation functions as shown in the following figure individually or together 4 Generate Run cared out WM Contact cross reference online DD a M Interruption point cross reference M i wiring and wire list W Function text database lf a generation run has been carried out before EPLAN indicates this by setting a check in the grayed fields on the right of the dialog box EPLAN 5 Basic Trai
79. re EPLAN 5 Basic Training System supported Assignment of Cable Designations Apart from the manual assignment of cable designations EPLAN also offers a system supported solution to designate defined cables lf you want to use it click on the selection button next to the Designation field in the symbol properties dialog box for the cable EPLAN then opens the Cable selection dialog box This dialog box provides an overview of all cable designations assigned in the schematic that have been defined by means of a cable definition line in the graphics EPLAN displays the cable properties of the currently highlighted cable in a separate field below Fr Wires that do not contain a cable definition line but that have been generated by the automatic assignment of the cable designation are not displayed in this dialog box There are two alternatives for the system supported cable designation 1 Highlight a designation listed in the selection dialog box and confirm by clicking OK 2 You want to use a designation that is not contained in the overview To do so click the Next button EPLAN then automatically suggests the next designation that has not been assigned yet After you have confirmed with OK the selection dialog box is closed and the selected or suggested designation is entered into the Designation field of the Symbol properties dialog box Finally click OK again and the new designation is read into the sc
80. re placed below the device designation For symbols that have been made cross referenceable the same method is used as for contacts Contact Image A contact image containing all cross references to a coil is drawn below the respective coil in the schematic The appearance of the contact image is governed by parameter settings The contacts are listed in ascending alphanumeric sequence of the connection designations An exception to this are changeover contacts Extract from a schematic page with contact image EPLAN 5 Basic Training Starting a Contact Cross reference Run Generate gt Cross references wiring list gt Generate gt Generate Proceed as follows to start the generation process Select Generate gt Generate in the Cross references module Then activate the Contact cross reference online DD check box in the subsequent Generate dialog box A checkmark in the grayed Run carried out field indicates that a contact cross reference run has been carried out before Once you confirm the dialog box by clicking OK EPLAN starts the contact cross reference run If contact cross reference errors occur in the project EPLAN outputs messages during the evaluation Creating Interruption Point Cross references This subchapter is about the creation of interruption point cross references First of all the terminology of the interruption point cross reference is explained in the following section Finally we will describe ho
81. red on graphics pages for the automatic evaluation Interactive pages These are pages that you create and edit yourself such as schematic pages or free graphics pages Automatic pages These pages are automatically created and processed by EPLAN This includes all pages whose data are first created during generation runs and then output as project pages e g terminal and interconnect diagrams etc EPLAN 5 Basic Training On the basis of the criteria mentioned above the various page types can be assigned to the following groups Groups Page types Interactive schematic logic pages PLC page Single pole display Interactive Free graphics graphics page Control panel layout Plot frame creation Title page cover sheet PLC overview Automatic Table of contents graphics pages Terminal diagram Terminal line up diagram Terminal connection diagram Interconnect diagram Bill of materials Device list Terminal strip overview Cable overview Purchase order list Wiring and wire list Special pages External document All pages belonging to one specific group are indicated by one standard symbol in the page overview For example all automatic graphics pages have the amp symbol see the section Symbols used in the page overview An exception to this rule is the interactive logic pages as a symbol is used for pages of the Schematic and PLC page type and another symbol for pages of the Single pole display page
82. rocess EPLAN can then also use multi function relays during contactor selection Coil 1 Coil 2 Use these fields to define the coils for the contactor or relay as well as the corresponding upper and lower connection designations By using the dropdown list box you can select the symbol names of the coils from the symbol file specified in the parameters under Symbol file EPLAN 5 Basic Training Multifunctional relay KMU Multifunctional rela KR Relay coil of a slow releasing relay OF7 15 07 KEZ Relay coil electric drive with dropout delay OF KEM Relay coil of a remanent relay 07 15 19 Latching relay Counter Fr Note that during contactor selection EPLAN compares symbol numbers of the coils In other words if it encounters the coil symbol KT in the schematic EPLAN will also search the contactor specification file for a coil designated as KT If you have not defined a coil with this designation in the contactor specification file EPLAN cannot find a matching contactor You should therefore take care not to make any incorrect entries wnen making a manual entry Contacts 1 to 12 Use these fields to define the contact configuration of the contactor or relay as well as the contact s connection designations Note that during contactor selection EPLAN compares contacts by the symbol number and symbol type For example for the contact symbol SL normally open power contact with a symbol type of 0 normally op
83. rrently set Master data FUES s lt sCS E Macros FUES is SCS Bi Parts data FUN i itsts SsSC es Print control forma FUES s SCS E Cancel Use this dialog box to specify the directories for the shared data By doing this you also determine the directories into which the associated files can be copied afterwards Select an option from the Directory structure group box The following options are available Original as saved The directory structure of the reloaded project is applied Project related The directory structure is copied from the directory that was specified in the previous dialog box for the project name EPLAN 5 Basic Training Currently set The directory structure of the currently selected project is applied The directories of the selected directory structure are shown in the fields below These directories can be changed which is useful if a different directory is to be used e g for the macros When you click OK the reload procedure will be continued and you will be asked what should be done with the associated files Reloading Additional Data Reloading other data master data macros parts data print and control forms personal and workstation files is done in the same way After having selected the corresponding menu item from the Reload menu you must choose the directory of the data to be reloaded in the selection dialog box Afterwards you may change the t
84. s Minimize unused contacts and Number of unused contacts permitted have no effect in this case In the case of power contacts all contacts are offered for selection EPLAN 5 Basic Training When you click on the Display button the settings will become effective Afterwards the list box will be filled with the contactors valid under the selected parameter setting A warning message may also appear informing that no contactor could be found for these settings Ci Contactor not found due to parameter settings In this case you have to use less restrictive parameter settings Online Contactor Selection EPLAN also allows you to select contactors online That is while you are creating a schematic When specifying the properties of the main coil select the Contactor selection button in the Symbol properties window 4 Symbol properties E4 Device Text display Parts Device designation K7 K Connection designations AAT Techn characteristics FO Supplementary field FO Function text PO Engraving data FO Mounting location Po Symbol number a7 o K2 K_ DIC_WUPE 1 Residual relay inhabiting contactor E Angle variant jo 0 l Symbol type 50 Main eoi 0 Contactor selection Hesewe contarle mea EPLAN 5 Basic Training EPLAN then initiates the selection run for the current contactor and loads the part number the connection designations as well as the technical characteristics You can
85. splayed on the left hand side of the element if the connection designation in the schematic is identical to the connection designation in the contactor Furthermore the coil voltage and the contact rating are displayed for the selected contactor Depending on the parts program specified EPLAN parts management or other ERP these data are taken either from the master parts file of from a transfer file extension tptT This requires that you have entered the contactor in the parts file under a part number that is identical to the part number you entered in the contactor specification file You will find a list box below in which you can select the contactors For each con tactor and possibly the associated auxiliary block the part number and the type des ignation is displayed For the part number a variant may be defined column Var Note that EPLAN also displays combinations of a single contactor with various aux iliary blocks Fr Please note that you only transfer the contactor for the current device by clicking on the OK or Apply button Therefore it is not sufficient to select several contactors and confirm the transfer of all contactors by clicking on OK At the bottom of the dialog you will find a group box Here you can adapt the settings for the contactor selection selected in the parameter management for this selection process Only the selection file to be used cannot be changed here Fr Please note that the two option
86. t of the device can be found in the schematic There are the following contact cross reference types e Contactor cross references cross references between the contactor coils and the contacts e Symbol cross references cross references between general symbols Pair cross references cross references between contacts Counter cross references cross references between symbols that were made able to be cross referenced e Contact image image of all the contacts that are cross referenced with a contactor coil lt gt v abe at Ee Cross reference between Sas relay and contactors Contact image m Drrers contact designations m Contactor murronng T gt Cross references between general syrabo m Drers contact designations C Cross referens between contactors IvIotor overload relay m Same contactor detinitior The individual cross references are generated in different ways ePLAN 5 EPLAN 5 Basic Training Contactor Cross references Coils and contacts are marked correspondingly when the symbol is designed in the symbol editor Here the symbol type is specified which defines the symbol as coil or contact symbol A cross reference to a coil symbol is drawn in the form of a contact image whose appearance is defined in the graphics parameters Thus coils and contacts are by their nature able to be cross referenced while other cross references are generated as a result of the respective elements hav
87. t on Page 51 Explanation The last page number is 46 You have to add 4 blank pages which results in 50 as last page number This result is rounded up the next full 10 so that the last page number is 50 Therefore 51 is the first page of the table of contents Output method Use this parameter to adjust the output of the table of contents to your project type It is for example possible to output a separate table of contents for each higher level assignment of your DIN project EPLAN 5 Basic Training The dropdown list offers the following options Entire output This option enables you to output the entire table of contents at a defined position By higher level assignment This option allows you to output the table of contents separately for each existing higher level assignment By location designation This option allows you to output the table of contents separately for each existing location designation KKS Using this option you can output the table of contents separately for each document and documentation type Entire output and by higher level ass This option enables you to output the entire table of contents at a defined position and in addition by higher level assignments Entire output and by location des Using this option you can output the entire table of contents at a defined position and in addition by location designations Entire output and KKS This option enables you to output the en
88. tion of EPLAN LOGOCAD TRIGA FRIEDHELM LOH GROUP EPLAN 5 Basic Training EPLAN Topics and Contents Basic Working Methods Defining personal directory settings Editing projects EPLAN page types Using the working window of graphics editing Using macros Automatic Evaluations Generating cross references and associated lists Contactor selection Terminals Cables Creating a table of contents Backing up data Exercises Creating a sample project incl data backup EPLAN 5 Basic Training Defining Personal Directory Settings Utilities gt Parameters gt Personal gt Directories The Directories option under the personal parameters is used to specify the directories in which the programs should search for specific files The individual EPLAN files are distributed among the following different directories Projects In EPLAN projects are saved in the directory zPLan4 p This directory is created during the installation and cannot be changed by the user But it is possible to create subdirectories under this directory in order to make project management easier Master data These include symbol files plot frames parameters and plot forms Print forms are filed in a separate directory refer to Print control forms Macros Macros must be filed in a directory below EpLan4 m otherwise the program will not find them Parts data These are the files for the system internal stock management These i
89. tire table of contents at a defined position and in addition KKS oriented Manual Using this option you can highlight the pages to be output in the page overview of graphics editing and manually define the page designation the starting page and the output positions Creating and Deleting a Table of Contents Project gt Graphics editing output gt Extras gt Table of contents gt Create The table of contents is an overview of all pages contained in the project You create it by following the menu path Extras gt Table of contents gt Create in graphics editing EPLAN then reads the pages of your project and searches for a free space at which the directory can be inserted You can either accept or change the page EPLAN suggests as the first page EPLAN 5 Basic Training 5 Select page for the creation Entire output Tz ma AEPLAN DEMO2 Page Higher level assignment Location designation 2 p Doku Type J Table of contents graphics automatic Designation Dinhaltsverzeichnis yEcontents Created by PFE License no wUP3o00060 Last editor FEH Page properties 1 Page properties 2 Drawing number Se Suppl field Page LLL Ln Suppl field Group A Document name E e Plot frame S Bi x Eom F ESSJO10E Z Use fern for plotting Resolution Number of ladders Paper size 0 I50 A3 without ma rgin oe Scale ll fio
90. u specify in which direction from the terminal in the schematic cables will be generated automatically Fr The automatic cable generation is not possible on single pole pages Utilities gt Parameters gt Project gt Terminals cables The cable that will be used is defined by your entries in the Standard cable type Standard number of conductors and Standard conductor cross section fields of the project specific terminal diagram parameters EPLAN 5 Basic Training 4 Parameters to create terminal and interconnect diagrams Terminals cables 1 Terminals 7 cables 2 Terminal subdivisiors Shielding target designation Conductor designation for shielding Load function tert Maximum cable designation length Cable number assignment Cable identifier Cable separator if 2 targets Standard cable type Standard number of conductors Standard conductor cross section Spare conductors in Minimun number of spare conductors Suppress duplicate HLA LOD Terminal sorting by HL amp LOD PLC designation If you use a terminal diagram form which provides for the PLC designations to be output the text entered here will be output The text in this field can be translated online The online translation function see the chapter on Translating Texts Online in the User Guide II is started by pressing the right hand mouse button to call up the Foreign languages pop up menu EPLAN 5 Basic Training Function text
91. utput Remark You can use this field to enter additional information about the specified cable definition The maximum length is 80 You can use any character except control codes EPLAN 5 Basic Training The entries made in the Designation Type Length No of conductors Cross section Voltage and Remark fields are displayed as cable definition texts on the schematic page once the dialog box has been closed If you want to display the cable definition texts in several lines you must enter a line feed behind the respective field entry To do this press the key combination or select the Line feed option from the pop up menu after you have entered the text In the text field a line break is represented by a T symbol Text Display of the Cable Definition In addition to the cable properties you can also influence the display of the cable definition texts in the properties dialog box This is done by using the Text display tab as is the case for general symbols from the symbol file see the section on Defining the Display of the Symbol Texts in this chapter s Symbol properties Cable Text display Line data Parts l Invisible Alignment Position s 400 Position r a00 Font size 2 1 6 mm Angle 1 vertical Undo position move EPLAN 5 Basic Training Line Data of the Cable Definition You can determine the line type and thickness as well as the pattern length for the actual
92. w to start a interruption point cross reference run Terminology of the Interruption Point Cross reference Interruption points are used to represent wires that go across more than one page The cross references represent the reference to the page in the schematic on which the wire continues Target tracking is carried out at the same time Target tracking means that a target is searched for each interruption point The target leads from this interruption point to the next component EPLAN 5 Basic Training The following section defines some of the terms used in the creation of interruption point cross references Target Targets are defined as all those symbols that represent a device Other graphics symbols such as angles and nodes cannot be targets although they influence target tracking Target tracking EPLAN searches for a target for every interruption point The search continues along the generated wires until a target is detected Counter target Where two interruption points that belong together appear on different pages the target DD always has a corresponding counter target Target wiring The target information for the wiring is important for target tracking This is particularly true when nodes are used If point wiring was used to draw nodes in the graphics a sensible definition for target tracking must be included so that the wiring will produce the desired results Incorrect Correct target wiring wr
93. you use a dropdown list box to specify whether the information will be output left justified centered or right justified relative to the path on which the contactor coil is located Documenting the Contactor Selection The Print option offers the following functions for printing the contactor data Print contactor specification file Print selected contactors Print contactors not selected The procedure is the same for all lists The lists can be output to the printer the screen or a file Refer to the section Specifying the Output Format for Printing in the User Guide Il EPLAN 5 Basic Training Defining Contactor Lists Generate gt Contactor selection gt Contactor gt Contactor lists Contactor lists are used to limit the contactor selection to a part of the contactor specification file in order to for example meet specific customer requirements concerning the types of contactors you can use or to speed up the selection EPLAN offers two types of lists that you can define and activate after you have selected the Contactor lists function from the Contactor pulldown menu e Project specific contactor list e General contactor list 5 Define contactor list Specification file Contactor list M Preview C EPLANA N FOEOO0SD BD Project C DIN2V50D P SCHUETZ SCH C General C EPLANA4 NAFOES SCH Part number aA ooh _ The file name of the project specific contactor list is a fixed one You can speci