Home

NWKSP3 - ComNet

image

Contents

1. comnet Communication Networks INSTALLATION AND OPERATION MANUAL f A netwave NWKSP3 COMNET SOLAR POWERED SYSTEM Thank you for purchasing NetWave from ComNet This manual will cover how to install hardware on your enclosure Configure batteries cabling and mounting of the enclosure The NetWave NWKSP3 Solar off the grid power system is designed for applications where a remote camera or wireless repeater is needed but power is not available or the cost to run power is too expensive NetWave Solar is a complete system tor providing remote power to edge communications equipment The kit includes high quality photovoltaic solar panels valve regulated lead acid batteries outdoor enclosure solar charge controller PoE midspan injector and mounting hardware The steel outdoor enclosure has a gasket hinged lid with two tamper proot locks operated by a special key for high security The enclosure can be mounted on a two to four inch pole or wall mounted with the included mounting hardware The Solar Panels include a top of pole mount requiring a 4 diameter pole A side of pole mount is available as an optional accessory The included 30A solar charge controller supports an LCD screen for local diagnostics and system health monitoring Intelligent PWM charging mode and battery protection from overcharge and over discharge while the batteries provide outstanding deep cycle and cold weather performance INSTALLATION AND OPERATIO
2. MANUAL NWKSP3 Solar Panel Electrical Wiring Assemble The Solar Panels and run cable thru the cable glands on the bottom of the enclosure The cabinet should be installed ten feet or less below the panels to ensure the cables have room to enter the bottom of the cabinet and make their connections to the other components Do not connect PV cables to the controller yet it is recommended to connect the battery first Series Configuration To the Controller Enclosure Mounted to Pole with Clamps The NWKSP3 Kit will need to be configured in a 24V series Connect the MC4 Male Positive Connector to the MC4 Female Negative Connector on the other panel Connect the MC4 Male and Female connectors with the 15 600V PV cables and route the cable thru the glands into the enclosure Note The cables may ship as one 30 cable If this is the case you will need to cut the cable in half creating two 15 cables Please reapply the Twist Nut to the open end of the cables to prevent a short 15 MC4 Male and MC4 Female Cables TECH SUPPORT 1 888 678 9427 INS_NWKSP3_REV 07 10 14 PAGE 13 INSTALLATION AND OPERATION MANUAL NWKSP3 Battery Installation Insert batteries into the enclosure on their side and stack them Batteries Placed into the Enclosure Connect battery cables The NWKSP3 Kit will need to be configured in a series then connected to the controller First connect the 18 PV Cable from the Ne
3. Related Documentation 2 Website 2 Support 2 Safety 2 Overview A Legal Information 4 Introduction 5 Typical Setup 6 Mounting Assembly 7 Preparing the Enclosure 10 Pole Mount 12 Solar Panel Electrical Wiring 13 Battery Installation 14 Agency Compliance 17 GPL General Public License Statement 19 TECH SUPPORT 1 888 678 9427 INS_NWKSP3_REV 07 10 14 PAGE3 INSTALLATION AND OPERATION MANUAL NWKSP3 Overview Legal Information No part of this document may be reproduced or transmitted in any form or by any means electronic and mechanical for any purpose without the express written permission of ComNet Copyright Copyright 2014 ComNet All rights reserved Disclaimer ComNet reserves the right to make changes in specifications at any time without notice The information furnished by ComNet in this material is believed to be accurate and reliable However ComNet assumes no responsibility for its use TECH SUPPORT 1 888 678 9427 INS_NWKSP3_REV 07 10 14 PAGE 4 INSTALLATION AND OPERATION MANUAL NWKSP3 Introduction The NetWave NWKSP3 Solar off the grid power system is designed for applications where a remote camera or wireless repeater is needed but power is not available or the cost to run power is too expensive NetWave Solar is a complete system for providing remote power to edge communications equipment LEGEND Solar Panel WIRELESS CAT5 a lt POWER a D PoE i ETHERNET PoE Inject 4 oE Injecto
4. N MANUAL NWKSP3 About This Guide This guide is intended for different users such as engineers integrators developers and technicians It assumes that users have knowledge of the following Installation of electronic equipment Electrical regulations and guidelines Related Documentation The following documentation is also available on the disc that was included with your shipment as well as from http www comnet net Solar Charge Controller User Manual NetWave Wireless Unit User Manual Solar Panel mounting instructions included with the mounting hardware Website For information on ComNet s entire product line please visit the ComNet website at http www comnet net Support For any questions or technical assistance please contact your sales person sales comnet net or the customer service support center techsupport comnet net Safety Only ComNet service personnel can service the equipment Please contact ComNet Technical Support The equipment should be installed in locations with controlled access or other means of security and controlled by persons of authority Do not install equipment on wet or windy days Make sure you have assistance mounting the hardware Complete as much of the setup as you can on the ground in a safe environment TECH SUPPORT 1 888 678 9427 INS_NWKSP3_REV 07 10 14 PAGE2 INSTALLATION AND OPERATION MANUAL NWKSP3 Contents About This Guide 2
5. NFO EUROPE COMNET NET 2014 Communications Networks Corporation All Rights Reserved ComNet and the ComNet Logo are registered trademarks of Communication Networks LLC TECH SUPPORT 1 888 678 9427 INS_NWKSP3_REV 07 10 14 PAGE 20
6. e Grounding Cable Installed Mount the DIN Rail The DIN Rail can be mounted to the door backplate or sides of the enclosure DIN Rail installed on door TECH SUPPORT 1 888 678 9427 INS NWKSP3 REV 07 10 14 PAGE 10 INSTALLATION AND OPERATION MANUAL NWKSP3 Attached the DIN Rail Adapters to the Controller and Power Injector then clip to the DIN Rail u i r9 G 3 z al 5 amp i Controller and Power Injector Mounted on DIN Rail Plug the external thermal sensor into the interface of the thermal sensor on the left of the controller S LARLAND HA Ww Thermal Sensor Plugged into Controller Insert battery platform in the enclosure The cutouts in the platform are for routing cable under the batteries Battery Platform on Floor of Enclosure Be sure the front of the Platform is placed along the front edge of the Enclosure TECH SUPPORT 1 888 678 9427 INS_NWKSP3_REV 07 10 14 PAGE 11 INSTALLATION AND OPERATION MANUAL NWKSP3 Pole Mount If mounting to a pole use the 6 included Stainless Hose clamps to secure the enclosure to a pole For your safety we highly recommend mounting the enclosure before installing the batteries Enclosure Mounted to Pole with Clamps Add the cable glands and drain plug to the bottom of the enclosure after mounting Battery Platform on Floor of Enclosure TECH SUPPORT 1 888 678 9427 INS NWKSP3 REV 07 10 14 PAGE 12 INSTALLATION AND OPERATION
7. etailed information about the disposal of your old equipment please contact your local authorities waste disposal service or the shop where you ourchased the product TECH SUPPORT 1 888 678 9427 INS_NWKSP3_REV 07 10 14 PAGE 18 INSTALLATION AND OPERATION MANUAL NWKSP3 GPL General Public License Statement You may have received from ComNet products that contained in part free software software licensed in a way that ensures your freedom to run copy distribute study change and improve the software Such products include NetWave series of products As part of these products ComNet may have distributed to you hardware and or software that contained a version of free software programs developed by the Free Software Foundation a separate not for profit organization without any affiliation to ComNet See http www gnu org philosophy free sw html for more details If ComNet distributed any portions of these free software programs to you you were granted a license to that software under the terms of either the GNU General Public License or GNU Lesser General Public License License copies of which are available from http www gnu org licenses licenses html The Licenses allow you to freely copy modify and redistribute that software without any other statement or documentation from us ComNet will provide to anyone who contacts us at the contact provided below for a charge of no more than our cost of physically performing sou
8. gative terminal on one battery to the positive terminal on the other PV Cable Connecting Battery Terminals TECH SUPPORT 1 888 678 9427 INS_NWKSP3_REV 07 10 14 PAGE 14 INSTALLATION AND OPERATION MANUAL NWKSP3 NOTE Please apply rubber insulator to the terminals to prevent contact with the door in case of earthquake or vibration Rubber Insulator Connect the 24 10AWG Red and Black cables to the positive and negative battery terminals that were not used in the previous step PV Cable Connecting Battery Terminals Connect the Positive and Negative cables from the battery to the Controller battery terminals HAW 8 B Batterv Cables Connected to Controller Batterv Terminals TECH SUPPORT 1 888 678 9427 INS NWKSP3 REV 07 10 14 PAGE 15 INSTALLATION AND OPERATION MANUAL NWKSP3 Once batteries are connected to the controller connect the PV cables from the solar panels to the Solar Load terminals on the controller S LARLAND A vw Solar Panel Cables Connected to Solar Load Terminals on Controller Connect the 12 Bonded Red and Black cable to the green terminal adaptor then connect the other end of the cable to the load terminals on the controller Red and Black Cable Connected Green Terminal Connector left and to Load Terminals on Controller right Insert green terminal into the Power Injector Green Terminal Connector attached to Power Injector See Solar Charge Controller User Manual for i
9. ith any other antenna or transmitter Les antennes utilis es pour ce transmetteur doivent tre install en consid rant une distance de s paration de toute personnes d au moins 2 52m et ne doivent pas tre localis ou utilis en conflit avec tout autre antenne ou transmetteur CE Marking CE marking on this product represents the product is in compliance with all directives that are applicable to it This equipment may be operated in the following countries Great Britain and Northern Ireland Austria Belgium Denmark Finland France Germany Ireland Italy Netherlands Norway Portugal Romania Switzerland Sweden Installer Compliance Responsibility Devices must be professionally installed and it is the professional installer s responsibility to make sure the device is operated within local country regulatory requirements RoHS WEEE Compliance Statement European Directive 2002 96 EC requires that the equipment bearing this symbol on the product and or its packaging must not be disposed of with unsorted municipal waste The symbol indicates that this product should be disposed of separately from regular household waste streams It is your responsibility to dispose of this and other electric and electronic equipment via designated collection facilities appointed by the government or local authorities Correct disposal and recycling will helo prevent potential negative consequences to the environment and human health For more d
10. nstructions on how to use the controller Solar Panel mounting instructions will be included with the mounting hardware TECH SUPPORT 1 888 678 9427 INS_NWKSP3_REV 07 10 14 PAGE 16 INSTALLATION AND OPERATION MANUAL NWKSP3 Agency Compliance FCC Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions e This device may not cause harmful interference and e This device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a Industrial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Industry Canada This Class A digital apparatus complies with Canadian ICES 003 To reduce potential radio interference to other u
11. r G g Ethernet Ethernet NW7 PoE Camera The kit includes high qualitv photovoltaic solar panels valve regulated lead acid batteries outdoor enclosure solar charge controller PoE midspan injector and mounting hardware The steel outdoor enclosure has a gasket hinged lid with two tamper proof locks operated by a special kev for high securitv The enclosure can be mounted on a two to four inch pole or wall mounted with the included mounting hardware The Solar Panels include a top of pole mount requiring a 4 diameter pole A side of pole mount is available as an optional accessorv The included 30A solar charge controller supports an LCD screen for local diagnostics and system health monitoring Intelligent PWM charging mode and battery protection from overcharge and over discharge while the batteries provide outstanding deep cycle and cold weather performance This manual contains detailed operational and configuration information TECH SUPPORT 1 888 678 9427 INS_NWKSP3_REV 07 10 14 PAGE5 INSTALLATION AND OPERATION MANUAL Typical Setup Solar Panel Connects to Controller p L C ali y A s Lamera HE Ey Connects to NetWave Unit Max 10 feet aN From top of cabinet to solar panel OH NetWave Unit mount to allow for cable flex if Spe i ip l Connects to Power Injector and wiring through cabinet Cabinet ia a ji 9 Houses Batteries Controller ty Power Injector Drip Loops Use on all exte
12. rce code distribution a complete machine readable copy of the complete corresponding source code for the free software programs used in the version of the programs that we distribute to you The cost will be free if the delivery medium of the machine readable copy is through the Internet Contact information Email techsupport comnet net Tel 203 796 5300 Address 3 Corporate Drive Danbury CT 06810 USA We will reply within 7 working days once the request has been made through email or telephone TECH SUPPORT 1 888 678 9427 INS_NWKSP3_REV 07 10 14 PAGE 19 INSTALLATION AND OPERATION MANUAL NWKSP3 ComNet Customer Service Customer Care is ComNet Technology s global service center where our professional staff is ready to answer your questions at any time Email ComNet Global Service Center customercare comnet net Contact Information ComNet www comnet net bie or a ea ne aa tne Gee ce ar ee ve Tel 1 888 6789427 Email info comnet net E A A EE seers ange aed ase a a ComNet Europe Ltd Leeds Tel 44 0 113 307 6409 Email info europe comnet net sess ComNet Corporate Headquarters and Customer Support Center EMEA PACRIM South America 3 CORPORATE DRIVE DANBURY CT 06810 USA T 203 796 5300 F 203 796 5303 TECH SUPPORT 1 888 678 9427 INFO COMNET NET CO Mm n et 8 TURNBERRY PARK ROAD GILDERSOME MORLEY LEEDS UK LS27 7LE Communication Networks T 44 0 113 307 6400 F 44 0 113 253 7462 I
13. rior cabling NWKSP3 TECH SUPPORT 1 888 678 9427 INS_NWKSP3_REV 07 10 14 PAGE 6 INSTALLATION AND OPERATION MANUAL NWKSP3 Mounting Assembly If mounting the enclosure to a pole remove the orange panel mount from inside the cabinet Orange Panel Mount Removed from Cabinet Attach the horizontal mounting braces to the cabinet at the top and bottom Connect the two halves of the pole mount brace then attach them to the center of the cabinet through the center holes top and bottom Please refer to the diagram on the next page TECH SUPPORT 1 888 678 9427 INS NWKSP3 REV 07 10 14 PAGE7 INSTALLATION AND OPERATION MANUAL NWKSP3 Mounting Hardware Pole Mount TECH SUPPORT 1 888 678 9427 INS_NWKSP3_REV 07 10 14 PAGE8 INSTALLATION AND OPERATION MANUAL NWKSP3 Pole Mount Hardware mounted on back of enclosure Reinstall the orange panel after the pole mounting hardware is installed If mounting the enclosure to a wall you can skip this step and mount the enclosure directly to a wall by attaching the wall mount hardware via the 4 holes in the back of the enclosure Wall Mount Hardware mounted on corners of enclosure TECH SUPPORT 1 888 678 9427 INS NWKSP3 REV 07 10 14 PAGE9 INSTALLATION AND OPERATION MANUAL NWKSP3 Preparing the Enclosure Attach grounding wire to the door and enclosure Remove plastic covers on copper studs Add grounding cable to the two studs and use the copper washers and nuts to secur
14. sers the antenna type and its gain should be so chosen that the equivalent isotropically radiated power EIRP is not more than that permitted for successful communication This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions e This device may not cause interference and e This device must accept any interference including interference that may cause undesired operation of the device Cet appareil num rique de la classe A est confrome a la norme NMB 003 Canada Pour r duire le risque d interference aux autres utilisateurs le type d antenne et son gain doivent tre choisies de fa on que la puissance isotrope rayonn e quivalente PIRE ne d passe pas ce qui est n cessaire pour une communication r ussie Cet appareil est conforme a la norme RSS Industrie Canada exempts de licence norme s Son fonctionnement est soumis aux deux conditions suivantes 17 Compliance e Cet appareil ne peut pas provoquer d interferences et TECH SUPPORT 1 888 678 9427 INS_NWKSP3_REV 07 10 14 PAGE 17 INSTALLATION AND OPERATION MANUAL NWKSP3 e Cet appareil doit accepter toute interf rence y compris les interf rences qui peuvent causer un mauvais fonctionnement du dispositif RF Exposure Warning The antennas used for this transmitter must be installed to provide a separation distance of at least 2 52m from all persons and must not be located or operating in conjunction w