bs 181 single channel power supply user manual

image

Contents

1. AC power outlet before cleaning Use only a damp cloth for cleaning the exterior of the apparatus Do not use accessories or attachments not recommended by the manufacturer as they may cause hazards and void the warranty Do not operate this apparatus in high humidity areas or expose it to water or moisture Do not place the apparatus on an unstable cart stand tripod bracket or table The apparatus may fall causing serious personal injury and damage to the apparatus Do not block or cover any openings in the apparatus These are provided for ventilation and protection from overheating Never place the apparatus near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat Do not place the apparatus in an enclosure such as a cabinet without proper ventilation Operate the apparatus using only the type of power source indicated on the marking label Unplug the apparatus power cord by gripping the power plug not the cord 9 10 11 12 13 14 Insert the plug properly Do not defeat the safety purpose of the polarized or grounding type plug An American polarized AC line plug has two blades with one wider than the other This plug will fit only one way into the power outlet This is a safety feature If you are unable to insert the plug fully into the outlet try reversing the plug If the plug still fails to fit contact an electricia
2. The intercom line power supply is fully protected and can drive at least 10 beltpacks operating at full power 3 0 UNPACKING The shipping carton contains the parts listed below i The BS 181 R Power cable Spare fuses User manual If any are missing contact your dealer ASL has taken great care to ensure that this product reaches you in flawless condition After unpacking the unit please inspect for any physical damage to the unit and retain the shipping carton and relevant packing materials for use should the unit need returning If any damage has occurred please notify your dealer immediately so that a written claim can be initiated Please also refer to the guarantee section of this manual 4 0 MECHANICAL INSTALLATION Adequate ventilation must be provided by allowing sufficient space around the sides and rear of the unit to ensure free circulation of air Forced cooling is not required After a period of time the unit will feel warm to the touch This is quite normal and should be no cause for alarm 5 0 MAINS POWER WARNING This appliance must be earthed The BS 181 may be connected to a mains power outlet 100 240 V AC 50 60 Hz 60 watts The outlet should have a clean earth Avoid using mains power outlets which also power dimmer controlled lighting equipment The wires in the mains lead are color coded in accordance with the following code Green yellow Earth safety ground Blue Neutr
3. This principle has three advantages e the use of a single audio line allows several stations to talk and listen simultaneously e due to the high bridging impedance offered by each station the number of stations on the party line has no influence on the level of the communications signal e power and audio to the intercom stations use the same cable The Call signal is also sent as a current on the audio line It develops a DC potential over the line impedance which will be sensed by each station and interpreted as a Call signal The intercom lines the party lines are of the shielded two conductor microphone cable type The intercom line connectors are of the XLR 3 type Audio and Call signals are on pin 3 DC power is on pin 2 and pin 1 is connected to the shield of the cable which functions as the common return for audio and power To avoid earth loops hum and the possible effect of electromagnetic fields and to minimize power loss certain rules have to be obeyed when installing the cabling of an intercom system Use high quality cable Use high quality microphone cable shielded two conductor cable minimum 2x 0 30 mm2 In case multi pair microphone cable is used each pair should consist of two conductors minimum 2x 0 15 mm2 with separate shield and an overall shield Use flexible cable Use flexible single and multi pair microphone cable instead of cable with solid cores especially when the cable is subjected to bendi
4. high energy cables e g 115 230 400V mains power or dimmer controlled feeds for spotlights Intercom cables should cross high energy cables at an angle of 90 only Intercom cables should never be in the same trunks as energy cables Place power supply in a central position In case of a system powered by a separate power supply In order to diminish power losses place the power supply as close as possible to where most power consumption occurs in other words most user stations are placed ASL powered units to a clean mains outlet Master stations or power supplies should be connected to a mains outlet with a clean earth Other audio equipment may be connected to this mains outlet but avoid using an outlet which also powers dimmer controlled lighting systems in case of more complex installations don t hesitate to contact us Please send us a block diagram of the planned network with a list of all user stations and their positions and we are happy to advise you on cabling lay out PAGE 6 User Manual BS 181 Issue 2011 ASL Intercom BV 12 0 BLOCK DIAGRAM BS 181 Switched mode power supply deeg Line impedance Block diagram BS 181 C 1998 ASL intercom 13 0 SYSTEM CONFIGURATION BS 15 1 CHANNEL BELTPACK BS 181 1 CHANNEL POWERSUPPLY IS 141 SOUND amp LIGHT BEACON 1 CHANNEL SYSTEM CONFIGURATION Dote 14 6 2011 Sheet of PAGE 7 User Manual BS 181 Issue 2011 ASL I
5. ANALUG INTERCOM BS 181 SINGLE CHANNEL POWER SUPPLY BS 181 power supply intercom USER MANUAL Issue 2011 ASL Intercom BV DESIGNED amp MANUFACTURED BY ASL Intercom B V Zonnebaan 42 3542 EG Utrecht The Netherlands Tel 31 0 30 2411901 Fax 31 0 30 2667373 Email info asl inter com Web www asl inter com CONTENT OF THIS USER MANUAL 1 0 2 0 3 0 4 0 9 0 7 0 9 0 10 0 11 0 12 0 13 0 14 0 SAFETY INSTRUCTIONS eee GENERAL DESCRIPTION BS 181 UNPACKING EE MECHANICAL INSTALLATION eese MAINS POWER celle REAR PANEL CONTROLS amp CONNECTORS TECHNICAL SPECIFICATIONS BS181 PARTY LINE TECHNICAL CONCEPT EE IC EE BLOCK DIAGRAM B 181 leere SYSTEM CONFIGURATION ellen EARTHING CONCEPT leere PAGE 2 User Manual BS 181 Issue 2011 ASL Intercom BV 1 0 SE 8 SAFETY INSTRUCTIONS Please always follow these instructions to help ensure against injury to yourself and or damage to the system Read all safety and operating instructions before you operate the apparatus Retain all safety and operating instructions for future reference Heed all warnings on the apparatus and in the safety and operating instructions and follow all installation and use instructions Unplug the apparatus from the
6. al Brown Live In case the colors of the wires in the mains lead do not correspond with the colored markings identifying the terminals in your plug proceed as follows e hewire which is colored green and yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol which is or colored green e he wire which is colored blue must be connected to the terminal which is marked with the letter N or colored black e The wire which is colored brown must be connected to the terminal which is marked with the letter L or colored red Safety Earth The green and yellow wire of the mains cord must always be connected to the electrical installation safety earth or ground This is essential for personal safety as well for proper operation of the BS 181 and the other connected stations This wire is internally connected to all exposed metal surfaces Powering up Powering up procedure e Make sure that the power switch on the left side of the front panel is OFF e Connect the power cord to the rear of the station e Plug the other end of the power cord into a PROPERLY GROUNDED outlet e Turn on the power with the red button The green power LED illuminates indicating the BS 181 is active User Manual BS 181 Issue 2011 ASL Intercom BV 6 0 FRONT PANEL CONTROLS BS 181 power supply 1 POWER ON OFF switch Mains power push button for switching ON and OFF the power s
7. n to replace the obsolete outlet A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician to replace the obsolete outlet Route power supply cords so that they are not likely to be walked on or pinched by items placed upon or against them Pay particular attention to cords at plugs convenience receptacles and the point where they exit from the apparatus Do not overload wall outlets or extension cords as this can result in a risk of fire or electrical shock Unplug this apparatus during lightning storms or when unused for long periods of time Never insert objects of any kind into the apparatus through openings as the objects may touch Dangerous voltage points or short out parts This could cause fire or electrical shock Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as when the power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped User Manual BS 181 Issue 2011 ASL Intercom BV 2 0 GENERAL DESCRIPTION BS 181 The BS 181 is designed to be a power supply in an ASL intercom system and can be used in portable as well as fixed applications
8. ng during operation or installation Cable screens to XLR pin 1 The screen of each separate microphone cable and or the screen of each single pair in a multi pair cable should be connected to pin 1 of each XLR 3 connector Do not connect these screens to the metal housing of ASL units or XLR 3 wall boxes See Earthing Concept Connect metal cable trunks wall boxes and overall multi pair cable screens to clean earth Metal cable trunks metal wall boxes and overall multi pair cable screens should be interconnected and at the central earth point in the intercom network only be connected to a clean earth or a safety earth See section Earthing Concept Keep metal connection boxes and cable trunks isolated from other metal parts Metal trunks or pipes for intercom cables and metal connection boxes should be mounted in such a way that they are isolated from any other metal housing or construction part Keep cables parallel as much as possible When two multi channel units in a network are connected by more than one cable make sure that these cables are parallel to each other over the whole distance between those units When using multi pair cable parallelism is ensured in the best possible way Avoid closed loops Always avoid that intercom cables are making a closed loop So called ring intercom should not physically be cabled as a ring Keep cables away from electromagnetic sources Keep intercom cables away from
9. note must be included stating the faults found and a copy of the original suppliers invoice 9 0 TECHNICAL SPECIFICATIONS BS 181 Switch Mode Power Supply mains voltage range 100 240 V AC 50 60 Hz DC output voltage 30 V DC 5 ripple and noise 11 mV rms max output power 45 watts Dimensions amp Weight Width 176 mm Height 42 mm Depth 139 mm Weight 900 grams System Specifications dynamic range 80 dB call signal send 2 8 mA call signal threshold receive 2 4 V DC supply voltage 30 V DC 12 V 32 V line impedance 350 O 1kHz 2 2 kO DC audio level nom 18 dBu max 4 dBu 0 dBu defined as 775 mV into open circuit User Manual BS 181 Issue 2011 ASL Intercom BV 10 0 PARTY LINE TECHNICAL CONCEPT User stations in an ASL intercom system are connected via one or several party lines A party line offers two way full duplex communication and consists of standard microphone multi pair cable One wire is used as an audio line one as a power line and the screen of the cable functions as earth return Current drive is used for signal transfer Each station utilizes a current amplifier to amplify the microphone signal and place it on the common audio line where due to the constant line impedance situated in the power supply between XLR pin 3 and 1 a signal voltage is developed which can be further amplified and sent to the headphones or loudspeakers 11 0 CABLING
10. ntercom BV 14 0 EARTHING CONCEPT POWER SUPPLY Z1 Z2 Line Impedances Mains Earth Wallbox SF geg JL i IS ONLY ONE EARTHING POINT 2am KE ams Individual intercom line shield not to be connected with overall shielding WE r u SE e Overall shield of multipair cable and or metal cable trunk EARTHING CONCEPT ASL INTERCOM PAGE 8 User Manual BS 181 Issue 2011 ASL Intercom BV
11. upply 7 0 REAR PANEL CONTROLS amp CONNECTORS 2 POWER LED This LED illuminates if line power is supplied by the internal power supply intercom line DANGEROUS VOLTAGES INSIDE Disconnect power cord before removing cover nput 100 240 VAC 50 60 Hz serialnumber Fuse T1 25A CE 3 INTERCOM LINE connectors These two XLR 3 connectors are for connecting the user stations via standard microphone cable Pin assignments Pin 1 0 V ground shield Pin 2 30 V power wire Pin 3 audio wire 4 FUSE holder A fuse protects the BS 181 against severe internal damage in case of malfunction in the power 80 WARRANTY This unit is warranted by ASL Intercom to the original end user purchaser against defects in workmanship and materials in its manufacture for a period of one year from date of shipment to the end user section Disconnected the power cord before replacing the fuse Place the correct fuse in the holder T 1250 mA for all mains voltages 100 240V AC An extra internal fuse is located on the printed circuit board if necessary replace this fuse ONLY with a 4A 5 MAINS INLET IEC Mains connector For correct wiring and operation refer to section 4 0 Faults arising from misuse unauthorized modifications or accidents are not covered by this warranty If the unit is faulty it should be sent in its original packing to the supplier or your local ASL dealer with shipping prepaid A