Adash 3750 Monitoring System fflfflfflffl User Manual

image

Contents

1. Restructuring of Template DB Database Tree The Data Admin Project Editor creates a new Template DB as a mere list of data cells in a database tree root Such list becomes hard to read for a larger amount of measurements therefore needs to be divided to more branches of the database tree Restructuring of the database tree is performed in the DDS software We are going to perform division of measurements in the Template DB in the further text according to individual measuring cards and within each card we are going to divide the measurements according to measuring channels We have so far defined the measurement from only one card which we designated 6110 1 in a sub project of the Data Loader service Definitions of these measurements are specified in the Idi configuration file of the Data Loader service This file is used as an input for the Data Admin Project Editor which created data cells for the measurements in the Template DB and database connections for them in the adi configuration file We are going to divide the measurements further within one card into three database branches designated Common speed measurement and two channel AB measurements Channel A channel 1 measurements and Channel B channel 2 measurements Opening of Template DB Through item Database Select and Open you can open a table of all available databases Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For
2. Data Admin Project Editor Editor is started from the A3716 Setup ADI button Most of the parameters are passed to the editor You have already input these parameters during project creation in the A3716 Setup software their descriptions are mentioned in the A3716 Setup chapter In this software you can set following parameters Limits Because the computers have limitations disc sizes disc speed CPU speed etc and the A3716 system can produce much more data than SQL server can handle there is a option how to input some limitations in the system Online History set a required length of measured data history in the Online DB Unnecessary long history increases Online DB volume and slows down a Data Admin service response which is not desirable Therefore set only as many history hours as you are going to use during a measured data analysis The history makes sense only in case when you run Abnormal TCGs where you require recording of the data before occurrence of an extraordinary event We recommend you set it to one hour Max Normal DB Size set maximum size of normal database If Data Admin detects that normal database reaches the limit creates a new normal database with the same structure This improves the responsiveness of the system Reduction Described in the TCG editor section First reduction at sets when is the first start of the reduction Because the reduction process may take a while this is a way to set
3. A3716 Reg exe registering A3716 Server into system A3716 Server exe A3716 Server service A8716_Server log A3700 Server log AOPC_A3716 exe AOPC_A3716 OPC Server module A3716_Monitor exe A3716 Server Monitor bin o A3716 MeasEngine exe A3716 program for data acquisition o VA4coef LP HP filter coefficients o A3716 SignalAnalyser exe interface for quick signal analysis data o script a37 configuration of data acquisition o A4log logs of A3716 MeasEngine program Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 23 A3750 A3716 MeasEngine A3700 purpose is to configure the measuring HW and for collect data from it The data are exposed into shared memory where from they are being collected by AOPC A3716 This program is being monitored by A3716 Server and in case if this program crash A3716 Server restarts it immediately A3716 Server A3716 Server is program working as a watchdog for A3716 MeasEngine and is responsible for setting the configuration for the A3716 measuring HW On one A3716 hardware can run just one A3716 Server Communication runs over network as a TCP server on port 37160 and is awaiting commands from A3716 Setup like configure new measuring or restart the system E g when it receives the information that the configuration has changed it stores new co
4. MAC A3 ICP off 100mV g AC A4 ICP off 100mV g AC B1 ICP off 100mV g AC B2 ICP off 100mV g MAC B3 ICP off 100mV g AC B4 ICP off 100mV g Y AC C1 ICP off 100mV g AC C2 ICP off 100mV g MAC C3 ICP off 100mV g AC C4 ICP off 100mV g MAC D1 ICP off 100mVig MAC D2 ICP off 100mV g MAC D3 ICP off 100mV g MAC D4 ICP off 100mV g DC Tacho SN 00000X Every channel can be disabled by unchecking its checkbox this will disable all measuring bound with this channel To change the properties for the channel double click on the measuring This will enable changing the sensor settings To change the settings of multiple channels at once press right click on the channel with requested parameters and press Copy to It will show the list of channels select the channels you want to change and press OK AC Sensor Properties Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 33 A3750 x ICP on Sensitivity mV g Unit Position To change the property double clicks on it ICP on off selection of required setting accordingly the sensor type Sensitivity mV selected unit usually 1 10 100 user Unit select one of predefined units or if no one fits your sensor just enter your own Position the a
5. Save Edit Close Clicking New invokes the dialog to enter a new TCG name Enter a new TCG name xj Name 6110 1 Normal Static OK Cancel Enter the requested name 6110 1 Normal Static and confirm it with OK The new TCG will appear in the list and its parameters will be set to predefined values TCG type Normal active with 60 second period and with no reduction applied to data From the Reductions offer pick the requested reduction Weak which enters all the Normal TCG parameters Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 59 A3750 Teo Editor 4 TCGs TCG Ini File EXProgram Files Adash MMS6850 DEMO_MMS DEMO_MMS teg TCGs List E TCG Measurements List O New Rename Coy Delete Edt m TCG Parameters M TCG Control Measurements List 7 Abnormal M TCG on Period o S A Pretrig Bo min Prolong ps min Reduction No Reduction No Reduction weak Usual In order to have complete Normal TCG definition we need to add required measurements into the TCG Measurements List However the button Edit of this list is disabled If the Edit of any of the lists is disabled it means that TCG parameters were changed but they were not stored into teg files by Save Click o
6. We have used an external database server and the SQL server instance called mms in the example on the picture User Password Write the username and password under which the A3750 logs in the selected SQL server into these fields In the example on the picture we used the user sa system administrator who is logged in under the password adash File Paths DB LOG Check this field and write address paths to place the Online database and log files on a computer disk in neighbouring fields if the paths are different from paths the SQL server standardly uses In the example on the picture was the Online database created in the physical volume e in the SQL db folder The SQL server log file was directed to the volume c into the SQL log folder Both folders had to be created during installation of the SQL server this means before creation of the Online database by clicking Create Create You will create a new online database on the selected SQL server by clicking this button The whole project can be created without the online database but you will not be able to start it That is why we recommend to create the new Online database immediately after entering of all the Online DB Group parameters Check Clicking on this button tests connection of the Online database to your computer If this test is successful you may be sure that after you start a project the Data Loader service will connect to the selected Online database An objective of
7. and the measurements mentioned in it are continuously stored in the target DDS database called ABNORMAL DDS DB in the following text All working ABNORMAL TCGs they may for example differ by storage interval periods store the data in the same ABNORMAL DDS DB there is always only one ABNORMAL_DDS_DB in operation during abnormal situations DDS DDS software is intended for work of a diagnostic who is able to process the data stored in the DDS database into well arranged diagrams This is a general software that enables to process not only data from the A3716 online measuring system but from other measuring systems and vibration measuring instruments as well Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 14 A3750 Level 2 Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 210 A3750 List of Terms for A3750 Introduction For easy orientation in the Level 2 chapter of the manual it is necessary to know meanings of used terms We shall explain them in relation to the Level 7 chapter where we have basic descriptions of processes that run in A3750 We need to set the system to have the A3750 functioning properly All parameters are stored in sever
8. Admin Project Edition A e SE E E SE destined 18 TOG EGRO aeneo a a a E e a e AE E TS 18 A NN 18 dmi File Project Configuration File naco nnccn nr crac 18 Idi File Configuration File for Data Loader Loader Ini File 18 adi File Configuration File for Data Admin Admin Ini File 18 tcg File TCG and Reduction Definition File for Data Admin TCG Ini File 19 BETTA dd 20 A3716 A Wii A Da RDNS PURE RD 20 A3716 S Wisin pa 22 simplified scheme iii A a 22 SYM A 22 ASTIG Meas Engine sunera di 23 A371 GLSOIVOL Anis Merits iti ach Meanie ca ins 23 POPG2 ATi Aten a NELA Reed Da RU ee ter ett ae 23 A3716 Server MONO iii add anda Danese mai 23 A3716 Signal AnalySeR seres sis ie 24 ASTON AO ida 25 Computer Requirements ooooncoconncconoccconoconconccononano no ncnnnn cnn cnn 25 A a ao dat 25 OO 25 A3750 Including Related Software oooooccccconococcnonocnnccononnncnnnnnnncnnnnnnncnnnnnnncnnnnnnnnnnn nan nnnnnnnnnrnnnnnn 26 Working Directory oct aro AAE E E Oca rr DARA 26 Structure and Placement of Working Directory reatar 27 Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 3 A3750 CAOS eee NEE eee eer Pr errr errr rere reece E REDE RARE E RODES eee rece EO
9. For further technical and contact information consult www adash net www adash eu ADASH Ltd 63 A3750 Task We are going to create an Abnormal TCG which we will call 6110 1 Abnormal Static in the further text We are going to include all static measurements from the card 6110 1 into it The measurements will be Speed Smax Val A Val B Gap A and Gap B We require a measurement period of 20 seconds storing of the data measured two minutes before occurrence of an extraordinary event and five minutes after it We do not want to apply any reduction to the stored data TCG will be controlled by speed as the only control quantity We shall demonstrate later how we are going to determine the limits for TCG control When we are creating the Abnormal TCG definition we assume that you can create a Normal TCG definition as was shown before Entering of Name and Creation of TCG Frame We could start creating the Abnormal TCG the same way as we created our first Normal TCG in the previous chapter Here however we are going to take advantage of the fact that the TCG Measurements List of the previously created Normal TCG is the same as the TCG Measurements List of the Abnormal TCG that is being created We are going to copy the already existing Normal TCG and then modify necessary parameters At the end we are going to create the TCG Control Measurements List to complete the definition By clicking on TCGs in the main editor window you are goin
10. a Y 6110 1 Orda A IGUANAS PES Eno oas me O110 1 Gap A Y 6110 1 Aps A O 6110 1 Gap B Y 6110 1 Aps B Y 6110 1 Center Line AB y Parameters 5 type TIME unit um status user off id 8 Suspending of Measurements in Data Loader Project We can see the Available Measurements List in the right upper quarter of the picture The list has been read from the Idi configuration file of the Data Loader project file The TCG Editor can only read this file and does not allow to modify it Modifications can be done only through the Data Loader Project Editor The list items that are not marked by the y sign present the measurements that were suspended in the Data Loader project If we select such an item from the list see picture we will see the line status user off between the Parameters at the bottom right quarter The measurement was suspended by a user through the Data Loader Project Editor by the change of the item status from user_on to user_off The Data Loader service will not transfer suspended measurement data from the OPC interface to the Online DB It is like this measurement did not exist in the A3750 project at all If you want to suspend any measurement in a whole project e g due to sensor defect then always use this way of suspending it Suspending of Measurement in Selected TCG We can see the Registered Measurements List in the left half of the picture The list has been read from the tcg file of
11. are temporarily suspended but can be added to TCGs This setting can be changed by editing the Idi file only Clicking on any item from this list activates the selected measurement Parameters of the selected measurement are shown in the window Parameters These are parameters read from the Idi configuration file of the Data Loader service The selected measurement can be added to the Registered Measurements List by clicking on Multiple choice is possible in the list and so a whole group of measurements from the Available Measurements List can be added to the Registered Measurements List The multiple choice is performed standardly by mouse and Shift or Ctrl keys TCG Name 6110 1 Normal Static x M TCG Measurements List TCG Ini File Loader Ini File fe Program Files Adash MMS6850 DEMO_MMS4DEM fe Program Files Adash MMS6850 DEMO_MMS DE Registered Measurements List M Available Measurements List Y 6110 1 Speed Y 6110 1 Time B m Parameters type TIME unit um id Clicking on transfers all selected measurements from the Available Measurements List to the Registered Measurements List The Save button is enabled at the same time E M TCG Measurements List TCG Ini File Loader Ini File C Program Files Adash MMS6850 DEMO_MMS DEM fe Program Files Adash MMS6850 DEMO_MMS DE M Registered Measurements List Available Measurem
12. username and password for a user logon to the SQL server directory paths for the Alternative Path unless they are standard however they should not be standard with regard to recommendation that an Online DB should be located on a different physical volume 4 Entering of NormalDBName name for the Normal DB from which a Template DB name is derived as NormalDBName_template Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 2184 A3750 5 Creation of the adi configuration file and Template DB by the Data Admin Project Editor software by clicking on a single button 6 Creation of the teg reduction definitions and TCG definitions file by the TCG Editor software Addition of New Measurements into Existing Project in A3716 Setup 1 Selection of the project through A3716 Setup 2 Creation of new measurement definitions in A3716 Setup 3 Addition of new measurements into Template DB and creation of database connections for new measurements via Data Admin Project Editor into adi file by clicking on one button 4 Addition of new measurements into Normal TCG and eventually into Abnormal TCG via TCG Editor Data Admin Project Editor This represents a complete Data Admin project adi file maintenance system for experienced users However if it is invoked from the Data Admin Setup software which
13. 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 58 A3750 By clicking on TCGs in the main editor window you will switch the editor into a mode of creation of new TCGs and modification of parameters of already existing ones The upper left quarter of the window has a list of TCGs defined up to this point Parameters of the selected TCG are shown in the individual fields in the left bottom quarter A list of measurements included into TCG is in the upper right quarter A list of control measurements included into TCG is in the bottom right quarter This list is available only for Abnormal TCG Normal TCG does not have any control measurements defined Task We will create Normal TCG in the further text that we will call 6110 1 Normal Static We will include the static measurements from the 6110 1 card in it They will be Speed Smax Val A Val B Gap A and Gap B We require a one minute measurement period and we will apply the reduction Weak which we have created in the previous chapter on the data Teo Editor TCGs TCG Ini File C Program Files Adash MMS6850 DEMO_MMS DEMO_MMS tcg TCGs List TCG Measurements List New Rename Copy Delete Edit M TEG Parameters r TCG Control Measurements List 7 E Abnormal F TCG on Period s Pretrig min Prolong min Reduction No Reduction v
14. B 6110 1 Aps 6110 1 Aps B 6110 1 Center Line AB plate DEMO MMS tem Creation of 6110 1 Item A3750 Click on Root and then press Insert on the keyboard You will see the dialog window for creation of new item Fill in required fields and click OK Name emio Type bmp res Measurement Point Note Options Iv Common Graphs Machine Measurement Point r Sensor Sensor definition F Use L r Default rotation speed p Bearings po EM Absolute Bearing definition Real APM Relative p Machine type Jena item gt y r Scheme lt No item gt y Show Scheme E Zoomable Scheme Identification in Schemes ano item gt oe RA el Show Identifier Place in Scheme The new created item was added to the database tree Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 41 A3750 DDS2007 DEMO MMS template Database Trees es Tools Window Options Help 0 View Scheme rr Machine Cell Item 6110 1 Speed 6110 1 Smax 6110 1 Val A 6110 1 Val B 6110 1 Gap A 6110 1 Gap B GB 6110 1 Time A BB 6110 1 Time B EB 6110 1 Orbit AB WW 6110 1 Orda A bu 6110 1 Orda B plate 6110 1 Center Line AB 63 6110 1 DEMO MMS tem Creation of Common Channel A and Channel B Items Cl
15. DB Both database types are created as copies of the Template DB in the beginning Normal DB This is the DDS database whose data storage is controlled only by TCGs of the Normal TCG type The new empty Normal DB is always created by the Data Admin service unless it finds an already existing Normal DB to store the measured data The Normal DB tree is created as a copy of the Template DB tree Abnormal DB This is the DDS database whose data storage is controlled only by TCGs of the Abnormal TCG type The new empty Abnormal DB is always created by the Data Admin service if the service finds that a monitored equipment operation changed from normal to abnormal The Abnormal DB tree is created as a copy of the Template DB tree The existing Abnormal DB is closed and cast aside by the Data Admin service if the service finds that the monitored equipment operation returned from abnormal to normal Project The ASA of A3750 monitoring system is created in the A3716 Setup software and includes project file with dmi extension it contains global parameters for the whole project creation of empty Online DB registration of Data Loader and Data Admin services on a computer configuration of Data Loader service configuration of Data Admin service The Data Loader is configured directly in A3716 Setup and includes configuration file of the Data Loader project with Idi extension The Data Admin is configured in the TCG Editor and Da
16. OK The new reduction will appear in the Reductions List All the fields for entering parameters will be enabled and some of them will get filled by predefined values Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 50 A3750 x M Reductions TCG Ini File C Program Files Adash MMS6850 DEMO_MMS DEMO_MMS tcg Reductions List Reduction Parameters Name Weak From To No Reduction N ow fe days Shorttime Red M days Long time Red M days M Max Dilutions Statics Dynamics Short time s feo 300 Long time s eo fi 4400 m Levels of Static Value Change Realtive Short time ao Realtive Long time so Rename Delete Close Save Save as L new Reduction Intervals From a data reduction viewpoint there are three time intervals 1 No reduction New data do not get reduced for a defined period at all Access to the unreduced data is assured for the period which enables their detailed analysis in case of occurrence of an extraordinary situation This interval exists in each reduction 2 Short time reduction It partially reduces measured data in order to decrease their volume however it would still remain possible to follow development trends and perform analysis on the medium time data This interval do
17. Project Editor described in the previous chapter Starting of TCG Editor Software We can start it from the Data Admin Setup software which gives it all necessary parameters and information for further work with a selected project The main screen can be divided into two parts left and right Pe LG Controlled Groups Editor DEMO_MMS BI xj T Files ap Edit j Loader Ini File C Program Files Adash MMS6850 DEMO_MMS DEMO_MMS di Find Reducti Admin Ini File eductions C Program Files Adash MMS6850 DEMO_MMS DEMO_MMS adi Find TCG Ini File CAProgram Files Adash MMS6850 DEMO_MMS DEMO_MMS tcg Nem About Lei Exit There is the Files group at the left side of the window which serves for selection of project initialization files Loader Ini File name of the Idi configuration file of the Data Loader service This file is used as an input for the TCG Editor If it does not exist or if it does not contain any measurement definitions transferred by the Data Loader service from the OPC interface to the Online DB TCGs cannot be created Admin Ini File name of the adi configuration file of the Data Admin service This file is used as an input for the TCG Editor If it does not exist or if it does not contain any database connections of measurements transferred by the Data Admin service from the Online DB to the DDS database TCGs cannot be created TCG Ini File name of the tcg file with TCG definitio
18. Save you will save the change in the tcg file Adding Removing and Suspending Measurements in TCG Lists Each TCG definition contains the TCG Measurements List which is a list of measurements whose data should the Data Admin service transfer from the Online DB to the DDS DB within the TCG An Abnormal TCG definition must also contain the TCG Control Measurements List which is a list of static measurements which control starting or stopping of this TCG Work with both lists is methodically the same and enables Adding of measurements to the list The added measurements are moved to the list from the Available Measurements List Removal of measurements from the list The removed measurements go back to the Available Measurements List Suspending or reactivating of selected measurements The suspended measurements stay in the list only they will not be acknowledged by the Data Admin service A suspended measurement can be reactivated within the TCG definition at any time Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 69 A3750 TCG Name 6110 1 Normal Static x M TCG Measurements List TCG Ini File Loader Ini File C Program Files Adash MMS6850 DEMO_MMS DEM C Program Files Adash MMS6850 DEMO_MMS DE Registered Measurements List M 6110 1 Speed 7 6110 1 Sm
19. accessible for A3750 You can argue why the two Adash systems do not cooperate directly but across the intermediary The reason is simple Some required processing parameters are not available in A3716 measurement system e g true power etc but they should be monitored through A3750 Such data can be measured by other company systems and simply transferred to the OPC interface since it is already normalised A3750 monitoring system then loads all the necessary data from various sources in the same standard format We can imagine the OPC data interface as a shop counter where fresh products of different kinds are constantly replenished Every kind is on the counter represented by one piece e g one roll one pie Every product on the counter is labelled by an exact time of manufacture in our case with accuracy in fractions of seconds The counter can be supplied by a number of different suppliers however each of them has their own products that nobody else supplies e g buns and rolls and produce We can pick the products on the other side of the counter any time we want If we take a specific product the supplier immediately replaces it with a next one The new product can however have the same time of manufacture as the one we have previously taken Let us imagine that it is from the same production series the supplier just has at his disposal From time to time the supplier gets a new series with a new origin time stamp Then he
20. any dynamic measurements A multiple choice is possible as was described before in the description of creation of a new Normal TCG In the left upper quarter is the list of the TCG control quantities In our case this list is empty since the TCG that is being newly created has no control quantity assigned yet The description of the Registered Control Measurements List is identical to the Registered Measurements List description as it was described during editing of the TCG Measurements List Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 66 A3750 However the left bottom quarter is completely new and marked Control Parameters Here we can set limits and intervals of the control quantity which has been just selected from the Registered Control Measurements List Individual limit fields have these meanings VL Very Low limit L Low limit H High limit VH Very High limit Measurement units are shown behind the fields If there is no control quantity defined yet the text unit appears behind the field In case the list contains control quantities then their units read from the Idi configuration file appear behind the fields The limits are the limiting interval points with the following meanings O Ol O O O Very Low Low Normal High Very High Interval vL Interval L Interval Inter
21. as the control quantity TCGs are often controlled by speed ATTENTION The current version of the Data Admin service requires that all measurements from the TCG Control Measurements List are also contained in the TCG Measurements List Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 65 A3750 To say it differently all Abnormal TCG control measurements must be archived into the DDS database while the Abnormal TCG is running The editor solves this requirement as follows Measurements shown in the TCG Control Measurements List are not shown in the TCG Measurements List at the same time Measurements shown in the TCG Control Measurements List are written into the tcg file for Data Admin as they have been mentioned in the TCG Measurements List The Data Admin service continuously checks a table of project control quantities and sets control indicators for all project Abnormal TCGs according to the actual status The abnormal TCGs are started and stopped according to the actual status of these indicators To select the control quantities properly and set their limits and intervals is a key presumption of proper function of each Abnormal TCG Now we are going to demonstrate how to do it for the TCG controlled by speed only Task A monitored device has nominal speed 1200 RPM Operating speed is betwe
22. by software Warning Do not enable ICP powering when NON ICP powered signal source is used It can cause permanent damage to the connected signal source Absolute maximum ratings Stresses above the values may cause permanent damage to the instrument hardware Any AC or DC input max 30V peak O max 48V peak Accessories inputs LAN ps2 mouse keyb vga usb Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd seda A3750 Terminal block AC signal inputs AC 1 2 3 4 where terminal is signal input and also positive ICP powering voltage terminal is common signal ground and also negative ICP powering voltage ICP powering has to be enabled if needed DC signal inputs DC 1 2 3 4 terminal positive voltage The polarity of the DC signal can be reversed terminal negative voltage U20 20Vpc 10 10mA negative pole of the voltage is common signal ground U5 5Voct 10 50mA negative pole of the voltage is trigger signal ground TRIG trigger signal input where terminal is positive signal input and terminal is common trigger ground Triggered voltage level is software adjustable Negative trigger voltage cannot be directly measured NC Reserved We do not recommend to connect AC and DC common sig
23. cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 55 A3750 and we will demonstrate it on creation of the new reduction called Usual Let us assume that it only differs from the already existing reduction Weak by the Max Dilutions parameters By clicking on Reductions in the main editor window you will switch the editor into a mode of creation of new reductions and modification of parameters of already existing reductions If the reduction list consists of more items click on a name of the reduction which is the most similar to the reduction you want to create You can check its parameters in the right half of the window In our case there is only one item on the list with the name Weak xi Reductions TCG Ini File E Program Files Adash MMS6850 DEMO_MMS DEMO_MMS tcg M Reductions List Reduction Parameters Name weak From To No Reduction Now so days Shorttime Red M EN so days Longtime Red M so fe days Max Dilutions Statics Dynamics Short time s 60 300 Long time s eco fi 4400 mM Levels of Static Value Change Realtive Short time feo Realtive Long time ao Rename Delete Close Save Save as New Click on Save as and the dialog to enter the new reduction name will open You are already familiar with the dialog from the previous chapter Creation of First New Reduction E
24. data from the OPC interface to the Online DB at all 3 TCGs TCG Ini File fe Program Filest dashiMMSGSSOADEMO MMSSDEMO MMS tcg TCGs List TCG Measurements List 6110 1 Speed 6110 1 Gap B New Rename Copy Delete Edit M TCG Parameters TCG Control Measurements List I Abnormal M TCG on Period eo Pretrig po m Poong Do mi Reduction wek S Edit Close The added measurements are shown in the TCG Measurements List window and the definition 6110 1 Normal Static TCG is complete Saving of TCG Definition in tcg File If the Save is enabled click on it This will store the definition into the tcg file Then click on Close The window for work with TCGs will close and you will return back to the main window of the TCG Editor software Creation of First New Abnormal TCG We have learned how to define the Normal TCG in the previous chapter Creation of First New Normal TCG While the Normal TCG runs continuously the Abnormal TCG is started by an extraordinary event and finished by an end of one The beginning and ending of an extraordinary event is evaluated by the Data Admin service according to actual status of so called control TCG Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 62 A3750 quantities control TC
25. days The significant change value can be set differently for each reduction interval Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 13 A3750 DDS Database We have talked about the target databases as about DDS databases This designation stems out of the fact that we use a DDS software for further data analysis included in A3750 That is why we do not talk about the target database but about DDS database in the manual It is always designated as DDS_DB There is usually more than one target database that is why the DDS_DB is only a database type not the designation of one individual database Similarly as with TCG we divide the DDS databases into normal and abnormal According to TCG group types that control the data collection into the particular DDS database the particular database is of the same type NORMAL TCG controls the data collection during both types of operations and the measurements mentioned in it are continuously stored in the target DDS database called NORMAL DDS DBinthe following text There is usually more than one NORMAL TCG type group created They all store the data in the same NORMAL DDS DB there is always only one NORMAL DDS DB in operation ABNORMAL TCG controls the data collection only during an abnormal operation when it is started by its control measurement
26. decrease under 1 1 4 0 71 times the value of the last remaining value after the reduction Storing Reduction in tcg File The reduction definition is now complete and by clicking on Save it can be stored in the tcg file Further reductions are defined and stored the same way Finally clicking Close closes the window for reduction work and you will return back to the main editor window x Reductions TCG Ini File C Program Files Adash MMS6850 DEMO_MMS 4DEMO_MMS tcg M Reductions List 7 F Reduction Parameters Name Weak From To No Reduction N ow 30 days Shorttime Red M fao so days Long time Red M so fe days Max Dilutions Statics Dynamics Short time s fo fo Long time s 600 fi 4400 Levels of Static Value Change Realtive 2 Short time 20 Realtive Long time ao Rename Delete Close Save Save as New Creation of Another Reduction The procedure from the last chapter Creation of First New Reduction can be of course used during creation of further reductions However what often happens is that the reduction that is being newly created is very similar to an already existing reduction We would like to take advantage of this by copying of this reduction and changing some of its parameters The editor enables such procedure Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash
27. further technical and contact information consult www adash net www adash eu ADASH Ltd 39 A3750 Ja Data Sources Manager Instrument Close Backup Restore Compress Copy database Synchronize databases SOL Server administration Exit Database Select the Template DB from it designated In this case DEMO MMS template see filled in editor dialog window above confirm its opening by clicking on Open database Databases x Default database DDS2007 DD5S2000 DD5S2000 SAY Program FilestMMSB8504DD5200 DD52007 4 ram Files Adash DDS 2007en MMS D er MMS_new_data C Program Files Adash DDS2007 Z MMS new full data const C Program Files Adash DDS2007 Z MMS new full speed C Program Files Adash DDS2007CZ You will see the closed database tree with one item Root only Expanding of Database Tree Double clicking the Root item expands the database tree and its data cells appear Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 40 t DDS2007 DEMO MMS template Database Trees Resources Tools Window Options Help ca e Machine Cell Item Cel View Scheme Instrument 6110 1 Speed 6110 1 Smax 6110 1 Val A 6110 1 Val B 6110 1 GapA 6110 1 Gap B RB 6110 1 Time A GB 6110 1 Time B 6110 1 Orbit AB TW 6110 1 Orda A bu 6110 1 Orda
28. gives it most of necessary information itself it enables an easy work with the files for a regular user Input Idi configuration file of Data Loader project Outputs adi configuration file of Data Admin project and Template DB TCG Editor This represents a complete Data Admin project tcg file maintenance system for experienced users However if it is invoked from the Data Admin Setup software which gives it most of necessary information itself it enables an easy work with the files for a regular user Inputs Idi configuration file of Data Loader project and adi configuration file of Data Admin project Output tcg file of reduction and TCG definitions for Data Admin Files dmi File Project Configuration File This file contains global settings for the whole project All A3750 monitoring system software can then take its information from one source only from this file The file is created by the A3716 Setup software during creation of a new project Idi File Configuration File for Data Loader Loader Ini File This is the measurement definition file that the Data Loader service should transfer from the OPC server to the circular memory Online DB It is an output of the A3716 Setup A Data Loader does not work without it It is an input for Data Admin Project Editor and TCG Editor software adi File Configuration File for Data Admin Admin Ini File This is a database connection and other parameters file to set the Data Ad
29. ida 27 A3750 Pro ect Seok shoal caddis alaska les ae taeda bated DRE De ORAR 28 Information Necessary for Creation of New Project ria 28 PROPS SOW oie O a vel eee eed as 29 Creation of New Project sanana aa ieaiaia AEAEE nn 29 Procedure to create a new project ires cnn 29 Parameters and Buttons of Online DB Group serenata 30 Buttons in DataLoader Group ccceccceeeeeeeeeeeeeeeceeeeecaaeeeeaaeeeeeeesaeeesaaeseeaeesecaeeeseaeeeeeeseneees 30 Buttons in DataAdmin Group cococccnncccnonccononanononcnonoconnncc nn rca 31 Adding new A3716 into system erre nn anno nan nnn cnn cnn nan tara 31 SENO A AAA a a Bee 32 AG Sensor Properties iii a A A i eee 32 DE Sensor Properties sms ave an ee ey A alee ae 33 Tacho Prop rties ee ee a dd 34 Creating the measurements list ie rca 34 Data Admin Project Editor a as 36 Template DB DDS Databases Template oooonnocccinnncncccnnncnonocnnoncccnnnccnannn nono nn nannc car nnn ana antena 36 Data Adminm Project Editor xiii 37 Creation of New adi Configuration File and Template database oocccccccinncccncccconccnoonnnanannnonnos 37 Restructuring of Template DB Database Tree errar 38 Maintenance of Existing adi Configuration File eae 44 How to Add New Measurements to Project rear 44 Proc
30. into Pretrig Put 5 into Prolong Change Reduction to No_Reduction Short time and long time intervals were given in days in the Weak reduction definition However periods of extraordinary situation do not last days If there is a reduction set for the Abnormal TCG then it usually has a protective character only in case of extraordinary data collection that would last days After the parameters are modified click Save The changed parameters are stored into the tcg file but primarily the Edit buttons for TCG Measurements List and for TCG Control Measurements List get activated x TCGs TCG Ini File C Program Files Adash MMS6850 DEMO_MMS DEMO_MMS tcg TCGs List 17 TCG Measurements List 6110 1 Speed 6110 1 Normal Static 6110 1 Abnormal Static 6110 1 Gap B Nem Rename Copy Delete Edit M TCG Parameters gt TCG Control Measurements List IM Abnormal M TCG on Period po BH Pretrig po min Prolong Bo min Reduction No Reduction o f Edit Close We have inherited the complete TCG Measurements List and we are not going to modify it However there is still the most important part of definition of each Abnormal TCG assigning of a control quantity to the TCG Control Measurements List and setting its limits Abnormal TCG Control Quantity Each Abnormal TCG must have at least one control quantity Any static measurement can be assigned
31. is as if the measurement did not exist only in the definition of the selected TCG If we want to suspend a measurement inside of just one TCG definition then we should use this method Remember when suspending measurements in TCG If you suspend all measurements in the Registered Control Measurements List then the corresponding Abnormal TCG will never be started By suspending the last list item you will disable control of such Abnormal TCG The TCG will then behave the same way as if its Control Measurements List were empty Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 71 A3750 If you suspend a measurement from the Registered Measurements List it does not mean that data from this measurement cannot keep transferring thanks to some other TCG definition to the DDS database If you suspend a measurement from the Registered Measurements List and its data will not be transferred to the DDS database any more they will still accumulate in the Online DB which is not desirable In this case suspend the measurement in the Data Loader project as was described above Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu
32. keep the database within reasonable size limits The word reduce means that we do not store all available data A simple reduction means that the data is stored in larger intervals for example 15 minutes and the data in between is removed In case that the measured values are stable and acceptable such approach suits to diagnostic requirements A3750 however uses more sophisticated data reduction However if the measurements show fast changes the longer interval is not suitable and we need to store the data more often For example in case of a turbine start up we would want to store all available data i e the interval would be around one second A3750 must be able to accept such contradictory requirements Its activity takes place on two levels In the first level it stores the more reduced data and enables long time measurements with acceptable size of the database If the machine works within acceptable values the device is active only on the first level the second level is idle An activity on the second level wakes up only when one of the measured values is beyond the acceptable limits Then fast acquisition of data occurs and the values get stored into a different database than on the first level This fast acquisition on the second level lasts until the values return into the acceptable limits Then the operation of the second level ends The data collection on the first level keeps running it is not interrupted by the activ
33. offers the products from this series only i e there is always only the freshest on the counter We customers are on the other side of the counter and want to monitor all the products on it If we take the products we are only interested in the ones with different manufacturing times This means that we always before taking the goods from the counter check whether we did not take the product with the given time of manufacture already Measurement results from A3716 system and other process values from other sources are offered to an actual OPC server A3750 continuously and cyclically takes values of chosen types offered on the OPC interfaces If a new value shows up i e loading time is higher than in the last value it gets stored in amemory A3750 Monitoring System This summary name labels a group of software that ensure the whole above mentioned process Two main software that work directly with the measured data are Data Loader and Data Admin Data Loader reads values form the OPC interface and stores them in the circular memory Data Admin reads values from the circular memory stores the values in the target DDS databases reduces the data in the DDS databases evaluates critical limits starts the process of the fast data storage during an extraordinary situation Data Viewer Data Viewer is comparatively independent software that serves to display the last measured values and can also show their shor
34. origin is the time when the first control measurement changes value from acceptable to unacceptable how much data is stored after the end of an extraordinary event the end is the time when the last control measurement changes value from unacceptable to acceptable After the first reading you may think that there are possibly only two groups This is not likely For example in normal operation you shall request to store the static measurements every 5 minutes order analyses every 30 minutes and time signals every hour This way you shall create three normal groups It is the same for the abnormal ones in addition they shall differ by a used control measurement or by a list of control measurements The groups can be also differentiated by monitored machines A whole group can be easily switched on or off in the A3750 This is very useful during outages Each group controls data collection The abnormal groups control the data collection ONLY during an abnormal operation The normal groups control the data collection continuously i e during normal and abnormal operations They are not switched off during the abnormal operation A reason for this is a request for uninterrupted data trends in a target normal database The creation of the groups represents an elegant solution to how to simply and efficiently define data collection conditions It is enough to define characteristic signs once for each group and also all the measurements for
35. stay the same even after the reduction From the time point of view we can only order a maximum interval that can stay in the data after the reduction Thus defined interval among the data kept after the reduction is requested for two reasons 1 The significant data inside of the reduced interval cannot be removed and will stay available for further analysis even after the reduction In this case the reduced data will be more dense inside of this interval than in the interval with the unimportant data 2 During stable operation when the data stay practically the same for hours or even days and consequently unimportant the interval between them will be the requested maximum interval after the reduction This signals that no data are lost for example as a consequence of a monitoring system outage but are only strongly diluted as a consequence of the monitored equipment stable run The picture shows a situation where in the section Significant Data almost all the data after reduction remained On the contrary in the section Insignificant Data there are three values of uninteresting data remaining only to maintain the Max Dilution parameter Data before reduction Data after reduction O O O Max Dilution Max Dilution Insignificant Data O Max Dilution Significant Data O significant data that must be kept O stable data that can be removed Set the max requested data interval after reduction i
36. the Data Admin project file for the selected TCG The TCG Editor is used for creation and maintenance of this file which is then fully under your control The list items that are not marked by the y sign present the measurements that were suspended in the selected TCG The measurement was suspended directly in this window by a user by the change of the status of the checking field The Data Admin service will ignore the suspended measurement If this is an item from the Registered Control Measurements List then this suspended measurement will not participate in the control of its TCG However this does not mean that the same measurement could not participate in the control of other TCGs in whose definitions it is not suspended If itis an item from the Registered Measurements List then data from the suspended measurement will not be transferred by the Data Admin service from the Online DB to the DDS DB but again only within its TCG It does not mean at all that the data from the same measurement could not be transferred within other TCGs in whose definitions this measurement is not suspended Even the data from a suspended measurement can still be transferred into the DDS database however according to parameters from another TCG So this is a big change of behaviour with regard to the previous case The suspended measurements are suspended only within their TCGs but not in the Data Admin project And not at all in the whole A3750 project It
37. this product further development Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 8 A3750 Basic Description Individual Sensors Protection System Hardware unit OPC data interface Rack Ethernet Personal Computer A3750 Software DDS db SQL Database Please note that the following hardware is needed for the A3750 monitoring system 1 A3716 rack connected to protection system or to sensors 2 IBM PC type computer to run A3750 software 3 Ethernet connection between them i e standard LAN An addition the A3716 uses an OPC data interface This is a stand alone software that helps to exchange data between the measurement system A3716 and the monitoring system A3750 A3716 Online Measuring System A detailed description of A3716 measuring system is the subject of a separate manual we shall not deal with it here Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 9 A3750 OPC Data Interface This is a standardised data interface commonly used in machine control In other words this is a software that runs on a A3716 The main objective of the OPC is to load measured values from A3716 system and make them
38. this software is to let the user create and maintain the Data Loader service configuration file with Idi extension easily This file contains all parameter settings needed for the Data Loader Buttons in DataLoader Group After you configure the measuring described in next chapters and create Online DB the data acquisition will be started by pressing the Start button On configuration change DataLoader must be restarted to accept new parameters Meas interval This parameters means how often you need the measurings from the hardware This option helps to reduce the size of online database e g you want value every 5 seconds not all of them Zero means that you want as much values as possible OPC interval This parameter reduces the network traffic It tells DataLoader how often he checks OPC server A3716 for a new data It is recommended to set this value smaller then the Meas interval to be sure that all values are collected Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd sale A3750 Buttons in DataAdmin Group If you are using just DataViewer and not the DDS check Disable DataAdmin button This will disable the whole group If you wish to use DDS leave the button unchecked Start and Stop buttons starts stops DataAdmin s work shifting data from Online DB into DDS databases ADI button
39. which they shall be used Thus defined measurement groups are a one of basic building stones of a A3750 project They are designated TCG Time Controlled Group in the following text A normal operation TCG shall be called NORMAL_TCG in the following text An abnormal operation TCG shall be called ABNORMAL_TCG in the following text Measurement Reduction Data can be reduced in target databases This is a similar process as for a picture lossy compression We all know the jpeg format The objective of a compression is to lower a volume of stored data In general such procedure works as follows If measurement values are sufficiently similar then it is possible to keep only one representative value Such lossy compression shall be called reduction in the following text The reduction in A3750 allows a user to set so called significant change value in case of static measurements This value is in and for example a change smaller than 10 against a reference value is not significant The reduction set this way lowers the data volume at a time of a stable operation However in case of significant value changes it stores sufficient amount of data so that the user obtains complete information Additionally the reduction is divided into three time intervals They are data interval without reduction e g up to 7 days old short time reduction interval e g 7 21 days old data long time reduction interval e g data older than 21
40. will ensure that in case when a monitored equipment works at the edge of beginning ending of an extraordinary event the data will get collected into one Abnormal DB After TCG parameters are saved by clicking on Save both Edit buttons get enabled The enabling of Edit for the TCG Control Measurements List enables assigning of control measurements of an Abnormal TCG Prolong Parameter in Hysteresis Function The Prolong parameter has two functions 1 It enables to include data measured after the ending of an extraordinary event into an Abnormal DB 2 Creates hysteresis if a monitored equipment works at the edge of beginning ending of an extraordinary event Control measurement of Abnormal TCG Border of start end of extraordinary event Time Abnormal DB 1 AbnormalDB2 Prolong i Prolong gt _ gt Abnormal DB l O Start of extraordinary event End of extraordinary event The picture shows a situation in which during a short time two extraordinary events began and ended As a consequence of the parameter Prolong being zero two blue dot and dash line Abnormal DBs were created recording data from the individual extraordinary events On the contrary by choosing of a suitable non zero Prolong parameter we would create only one red continuous line Abnormal DB which would record data of both extraordinary events Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz
41. 1 3 1500 1950 RPM We are not going to analyse the reasons which led to the refusal of the first interpretation in detail here The Data Admin service uses the second interpretation The dependency of the upper and lower values on a selection of the is shown on the following graph and the table Please note that you can enter values higher than 100 and more This would not be possible with the first interpretation 3 0 hard PRE Ra RR RR RR AEE PRO OR IIA COPO N RR EPE PUT DOR ORAR AAA PR RR O 25 50 100 200 10 15 20 25 30 40 50 60 70 80 90 100 150 200 High 1 10 1 15 1 20 1 25 1 30 1 40 1 50 1 60 1 70 1 80 1 90 2 00 2 50 3 00 Low 0 91 0 87 0 83 0 80 0 77 0 71 0 67 0 63 0 59 0 56 0 53 0 50 0 40 0 33 Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 54 A3750 Levels of Static Value Change Realtive Short time 20 Realtive Long time ao This picture shows the situation where we require to keep static data after short time reduction whose values exceed by 1 2 times or decrease under 1 1 2 0 83 times the value of the last remaining value after the reduction to keep static data after long time reduction whose values exceed by 1 4 times or
42. 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 67 A3750 Only if any limit represents a change between checked and unchecked intervals it is really watched It is necessary to defined only the L limit for the next example O O El E E lt Recommendation ME E pl YA Fill allthe VL to VH fields even if you will not be using some of the entered limits The really watched limits in the order VL to VH must be increasing integers The complete Abnormal TCG definition created according to the previously specified task is as follows TCG Name 6110 1 Abnormal Static J x TCG Control Measurements List TCG Ini File Loader Ini File fe Program Filest dashiMMSBSSOADEMO MMSADEM je Program Files Adash MMS6850 DEMO_MM Registered Control Measurements List M Available Measurements List Y 6110 1 ValA Y 6120 1 Val B Control Parameters YL 1600 RPM L s00 RPM H 11200 RPM YH 11500 RPM Parameters VL L H W Save Close By clicking on Save you will save the definition in the tcg file Then click on Close to close the Control Measurements List creation and editing window this will return you to the TCGs creation and its parameter editing window ATTENTION When the 6110 1 Speed measurement is added to the TCG Control Measurements List it is not consequently shown in the TCG
43. A WW 6110 1 Orda B 6110 1 Aps 6110 1 Aps B plate 6110 1 Speed 6110 1 Smax 6110 1 Orbit AB 6110 1 Center Line AB al Channel A uty Channel B DEMO_MMS_tem You can move the data cells Val A Gap A Time A Orda A Aps A into Channel A and Val B Gap B Time B Orda B Aps B into Channel B the same way DDS2007 DEMO MMS template Database Trees Resources Tools Window Options Help UE MEYE ZA DO Machine Cell Item Cell View Scheme Instrument E Root SES 6110 1 Common 6110 1 Speed 6110 1 Smax 6110 1 Orbit AB 6110 1 Center Line AB Channel 6110 1 Val A 6110 1 Gap A BB 6110 1 Time A GY 6110 1 Orda A 6110 1 Aps A plate Channel B 6110 1 Val B 6110 1 Gap B GB 6110 1 Time B 6110 1 Orda B 6110 1 Aps B DEMO MMS tem A DDS database template was created by creation or eventual restructuring of the new Template DB The Data Admin service will create the Normal database for data collection during a normal as well as Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 44 A3750 abnormal operation of a monitored machine by copying the template after it is started for the first time In case of extraordinary situations the Data Admin service will create Abnormal databases by copying the same template to collect data during abnormal operations of the monito
44. AM 2 GB or more recommended two physical discs on SQL Server machine A8716 rack connection with the computer over gigabit network Software supported OS are Windows XP 32bit Windows Vista 32 64 bit Windows 7 32 64 bit and Windows Server 2003 or 2008 supported SQL Servers are MS SQL Server 2005 and MS SQL Server 2008 Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 226 A3750 A3750 Including Related Software The basic software of A3750 monitoring system are the following programs Data Loader service that transfers measured data from the OPC interface to the Online database Data Admin service that transfers data stored in the Online database to the DDS databases Data Status software to control and monitor working of the whole system To ease the configuration and registration of these programs there are A3716 Setup Software to create a project and configuring measurings Idi Data Admin Project Editor Software to create and maintain the adi configuration file of the Data Admin service and to create and maintain template of the DDS databases TCG Editor Software to create and maintain the tcg file of TCG and reductions definitions of the Data Admin service For quick visualization of the Online database we provide Data Viewer software to online monitor selected data stored in t
45. Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 47 DDS2007 DEMO MMS template Database Trees Resources Tools Window Options Help Ja zap IO Y Gell Scheme Instrume 6120 1 Speed 6120 1 Val A 6120 1 Val B GB 6120 1 Time A BB 6120 1 Time B 6120 1 Orbit AB bu 6120 1 Orda A TW 6120 1 Orda B 6120 1 Aps A 6120 1 Aps B PEI 6110 1 plate Common Channel Channel B DEMO_MMS_tem Moving of Data Cells A3750 By using double combinations Ctrl X and Ctrl V gradually move the data cells in groups from the Root item to the Common Channel A and Channel B items This procedure was described before during creation of the 6110 1 branch Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 48 A3750 ICG Editor An objective of this software is to let a user create and maintain the Data Admin service TCG definition file with teg extension easily This file contains a part of parameter settings needed for the Data Admin It especially contains data reduction definitions and TCG definitions Remaining parameters are contained in a configuration file with adi extension for whose creation and maintenance we have the Data Admin
46. E Channel li Channel B template DEMO MMS tem After selecting all items release Ctrl Press Ctrl and X together this combination is known from other software ATTENTION In this case the combination Ctrl X does not remove cells from the Root it does not cancel their selection either they are only ready to be moved Click on the Common into which you want to move the cells Their selection is cancelled now The data cells remain in the Root item even after they were deselected DDS2007 DEMO_MMS_template Database Trees Resources Tools Window Options a Ja TESES Machine Cell Item view H al Root 6110 1 Speed 6110 1 Smax 6110 1 Val A 6110 1 Val B 6110 1 Gap A 6110 1 Gap B BB 6110 1 Time A BB 6110 1 Time B 6110 1 Orbit AB TW 6110 1 Orda A TW 6110 1 Orda B 6110 1 Aps A 6110 1 ps B 6110 1 Center Line AB template Channel B DEMO MMS tem A double combination Ctrl V moves the cells from Root to a selected item in Common Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 43 A3750 DDS2007 DEMO MMS A Database Trees Resources Tools 1 Options Help Jz ETE El Machine Cell Item Cell View Scheme Instrument Root 6110 1 Val A 6110 1 Val B 6110 1 Gap A 6110 1 Gap B GB 6110 1 Time A GB 6110 1 Time B ht 6110 1 Orda
47. G measurements For this reason must a Abnormal TCG definition contain at least one item in the TCG Control Measurements List All active Normal TCGs store the continuously measured data into one Normal DB This exists all the time during normal and abnormal operations of a monitored equipment Similarly all concurrently running Abnormal TCGs store their data into one Abnormal DB The difference is While Normal DB exists continuously the Abnormal DB creates the first starting Abnormal TCG only after the start of an extraordinary situation All running Abnormal TCGs will store data into this newly created Abnormal DB now After the extraordinary situation ends the last finishing Abnormal TCG at its end closes the Abnormal DB used up to this point and casts it aside The next extraordinary situation invokes creation of another new Abnormal DB and the cycle repeats itself Definition of an Abnormal TCG differs from the one of a Normal TCG in these points The Abnormal field is checked in the TCG Parameters group This makes the fields Pretrig and Prolong accessible We can enter how many minutes of data measured before the beginning of an extraordinary event should be stored in this TCG into the Pretrig field We can enter how many minutes after the ending of the extraordinary event should the TCG stay active as if the extraordinary event continued into the Prolong field This parameter should always be non zero The non zero Prolong parameter
48. Measurements List Adding of More TCGs Other TCG definitions can be added to a project by two ways 1 By creating a complete definition from scratch This procedure was described in the chapter Creation of First New Normal TCG in detail 2 By copying of an already existing TCG definition which has similar parameters and especially the TCG Measurements List or TCG Control Measurements List This procedure that can make your work significantly easier during creation of the new TCG since you do not have to create a complete definition but only modify some of its parameters and lists was described in the chapter Creation of First New Abnormal TCG in detail Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 68 A3750 Remarks If you create a new Normal TCG from the copy of an already existing Abnormal TCG all you need to do is to deactivate the Abnormal field The TCG Control Measurements List becomes inaccessible so it is not necessary to erase its items in advance Even if some list was generated into the tcg file it would be ignored for the Normal TCG On the other hand if you create a new Abnormal TCG by copying an existing Normal TCG you must after checking the Abnormal field and making the TCG Control Measurements List accessible create a corresponding list of control quantities Ch
49. User Manual r oN El asha Adash 3750 Monitoring System Ref 18102010mka ADASH Ltd 2 A3750 Contents Howto Use This Manuali rasas SA Sa 4 A E ER RR 5 A tetaaa REED Rat ear 6 Always Available Counselling for A3750 Directly from Manufacturer 7 Basic Description ac ae cee et ci eee ee 8 A3716 Online Measuring System rente are rn cra 8 OPC Data Intenmaces ii A TER ENC RAE idan ER DOTE RIE 9 A3750 MONTON System sas canina aie Gan nigh Wir A aaa 9 Static and Dynamic Measurements nono nn nnnn crac 11 ConiroliMeasurements ui ad EREE ATESAT EAE EE TE IENA 11 Normal and Abnormal Machine Operation ccccccceceeeeeeeeeceeeeeceeeeeseaeeeeaeeseeeeeseaeeesuaeeseeeseaes 11 Grouping ot Measurements vcc sccasercteceteseisbes abate 11 Measurement Reductores snio ers areias En E E A A A EEEE E S E 12 DDS Databases euan E A EAE E atrai Aid 13 DDS seia nato E E E A AE E 13 A E E E 14 LISO Terms for AT apa Ri ae 15 oligo o 8 ot io a iia A eda ai OE el pen ee aaia 15 Databases iaee iniae ii aa a a ia deii E A ee ee 15 Online DB Circular M Mory ccccccceeceeeeceeeeeeeeceaeeecaaeeeeaaeeeeeeceaeeesaaesseaeeseeeeseaeeesaaesseneeenaes 15 Template DB Template for DDS Databases ear 15 DOS DB A E dieta 16 Normal DB tiara ra 16 O NN 16 NN 16 Managing Projects cucuta 17 AS sedoso E E EA T D 17 Data
50. al text files it means that they can be opened and read by many common software e g Notepad in Windows XP We need to register several services in a computer in order to have A3750 functioning properly If this sentence is not quite clear to you do not worry Services are software just like other ones we are used to Only they start automatically during a Windows system initiation and run before a user is logged on We have already mentioned a term Project This includes both files and registrations We are talking both about a whole A3750 project and about partial projects belonging to individual software We also talk about databases abbreviated as DB further in the text Databases Online DB Circular Memory So far we have talked about a circular memory into which a Data Loader service stores data Also this memory has a database structure and we shall call it Online DB in the further text A data cell is its basic building block An empty Online DB is created in the A3716 Setup software during a set up of a new project The Data Loader service creates the cells in the empty Online DB The Online DB works as a circular memory into which the Data Loader service stores measurement data from the OPC interface and so creates a time history with defined length All measurements defined in a configuration file of the Data Loader are stored in the circular memory without any reduction Template DB Template for DDS Databases A D
51. ange of TCG Parameters If you change parameters of a TCG these changes will come into effect only after restarting the Data Admin service which after it is started read the tcg file with the new parameters It is possible to change parameters of any already defined TCG in a project Most of the changes is done by overwriting of the parameter value in the corresponding field of the edit window or by adding the measurement into or removing it from the TCG list We have become familiar with all Normal TCG and Abnormal TCG parameters and important elements of the window for work with TCGs and their measurement lists in the chapters Creation of First New Normal TCG and Creation of First New Abnormal TCG We assume in the further text that you can create a new Normal and new Abnormal TCGs Change of TCG Name Each TCG must have its name under which it is in the TCG Editor in the TCGs List and under which itis in the Data Admin service in its tables The TCG name must be unique in the list and serves as a TCG identifier only Its change does not cause any side effects only the TCG will be under a new name from then on Renaming of a TCG is done as follows Inthe TCGs List click on the TCG name you want to change Click on Rename The dialog to enter a new name appears Enter the new TCG name which may not be contained in the TCGs List yet and confirm it by OK The TCG will appear in the TCGs List under the new name By clicking on
52. ata Admin service creates a new DDS database and its measurement structure tree as a copy of Template DB A Data Admin Project Editor creates and maintains the Template DB It makes sure that during creation of a new project the corresponding Template DB shall be created and that newly defined measurements shall be added into the already existing Template DB So a user does not have to worry about Template DB maintenance with one exception The Data Admin Project Editor creates all new data cells in a database tree root If the Template DB and consequently Normal DB and Abnormal DB does not suit to the user as a mere list of the data cells in the database tree root user must maintain the tree structure which means that user must always move the cells using a DDS Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 210 A3750 software from the database tree root into a required tree branch after an editor adds the new data cells DDS DB The measured data are stored into DDS databases by the Data Admin service Individual TCGs see reduction and a TGC definition file for the Data Admin define what measurements and with what reduction should be stored We recognise two types of the DDS databases according to a type of the TCGs which control storing of the data into the databases Normal DB Abnormal
53. ax Y 6110 1 Time B Y 6110 1 ValA Y 6110 1 Orbit AB Y 6110 1 Orda A A ES re SA Y 6110 1 Aps A V 6110 1 Gap B Y 6110 1 4ps B 6110 1 Center Line AB y Parameters Available Measurements List Adding of Measurement to List In the chapter Creation of First New Normal TCG we have learned that measurements selected from the Available Measurements List can be moved to the Registered Measurements List by clicking on The selected measurement will be moved from the Available Measurements List to the end of the Registered Measurements List At the same time we have learnt that the measurements do not have to be moved individually but also in whole groups A multiple choice is possible in the Available Measurements List by a mouse together with Ctrl and Shift More information can be found in the chapter Creation of First New Normal TCG Removing of Measurement from List This is a procedure which is the exact opposite to the above described measurement addition procedure The measurement this time selected from the Registered Measurements List can be moved back to the Available Measurements List by clicking on The selected measurement will be moved from the Registered Measurements List to the end of the Available Measurements List In this case we always remove the measurements individually A multiple choice is not allowed in the Registered Measurements List Suspend
54. ccording to your image How to do it was already described above during creation of the new adi file Restructuring of Template DB Database Tree The Data Admin Project Editor created new data cells in a database tree root called Root If you want to move them to different tree branches you need to do it by the DDS software A detailed methodology of creation of database tree branches and moving of data cells was described step by step in the chapter of the same name earlier during restructuring of the newly created Template DB Now we will consider only differences We will start from the database tree Template DB that we restructured immediately after creation of the new template We have added another root to this tree called 6110 1 into which we moved all the 6110 card measurements from the Root item These measurements were added to the Root automatically by the Data Admin Project Editor during creation of the new adi configuration file Now we are in the phase when we have added the new measurements from the 6120 card to the project through the Data Admin Project Editor and the editor automatically created data cells for them in the Root item We shall create a new branch called 6120 1 and divide the measurements in it Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 46 A3750 according to the m
55. dash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 57 A3750 Reductions List im Usual 2 The reduction is being selected from the list of defined reductions in case of its assignment to TCG The assignment is done in the editor window for work with TCGs in the part called TCG Parameters Reduction lf you rename any reduction do not forget to assign the new name to all TCGs which used this reduction before If you leave it the original name which does not exist anymore the Data Admin service will not perform any data reduction M TCG Parameters J Abnormal M TCG on Period so s Pretrig fo min Prolong fo min Reduction No_Reduction No Reduction Weak Usual Save Reduction renaming is done as follows In the Reductions List click on the name of the reduction you want to rename Click on Rename The dialog to enter a new name appears Enter the new reduction name which may not be contained in the Reductions List already and confirm it with OK Anew reduction will appear in the Reductions List with the new name Click on Save to store the changes into the teg file Creation of First New Normal TCG If the tcg file does not have any TCGs defined a project is not complete and it does not make sense to start it In order to transfer any measurement data from the OPC interface all the way to the DDS database this measurement mus
56. duction parameters and with important elements of the window for work with reductions It is assumed in the further text that you are capable of creating a new reduction Now we will demonstrate what parameter changes are offered by the editor x m Reductions TCG Ini File C Program Files Adash MMS6850 DEMO_MMS DEMO_MMS tcg m Reductions List Reduction Parameters Weak Name Usual From To No Reduction Now so days Shorttime Red V fao so days Long time Red M so fe days Max Dilutions Statics Dynamics Short time s feo 300 Long time s feoo 14400 Levels of Static Value Change Realtive Short time zo Realtive 2 Long time ao Rename Delete Close Save New Any parameter shown in the right half of the Reduction Parameters window can be changed by the following procedure Perform the change of one or more parameters by overwriting the value in the appropriate field Click on Save to store the changes into the tcg file Change of Reduction Name Each reduction must have its own name which unambiguously identifies it in two cases 1 The reduction is shown under its own name in the editor reduction work window in the window part called Reduction List Renaming of the reduction does not have any side effects with regard to the Reduction List Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info a
57. e of Adding New Measurements to adi Configuration File When we were creating the new project we have worked with the 6110 1 card measurements Now we have to add measurements from the 6120 1 card to a Data Loader service project This step is not described in this manual however it is the same as in creation of the new Idi configuration file of the Data Loader service Now the new measurements need to be added to the adi configuration file of the Data Admin service and concurrently to the Template DB 1 First you can change the parameter value of the Online History if it is not suitable 2 Click on Save and Finish If new measurements are found in the Idi configuration file the editor will create data cells for them in the Template DB and will add their database connections to the adi configuration file Finding of new measurements is announced by this information x 1 There are more than one root in the database Cells will be added to the Root item Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 245 2 A3750 This information is a consequence of restructuring of the Template DB database tree which we have performed after creation of the new Template DB If the tree was left in the original state as the mere list of data cells in the root of the database tree this information would not be wr
58. easurement channels into Common Channel A and Channel B branches just like before with the 6110 1 Opening of Template DB and Creation of New Items We will open the database and create the new items in it by the same procedure which was described before for the 6110 7 branch 2 DDS2007 DEMO MMS template Daaba Trees Resources Tools Window Options Help JM EM DM O Machine Cell Item Cel View Scheme Instrument ASS 6110 1 SS 6120 1 Common plate Channel An d Channel B E vu 2 n O W A Expanding of Database Tree Since the Root item is not the only item in the database tree any more we cannot expanded by the double click like before Display of the list of newly created data cells can be achieved by two methods Method No 1 Click on Root item and then press the key on the keyboard This will expand the whole database tree The tree can also be expanded by clicking the Root by right mouse button and selecting Expand all from the menu However expanding the whole tree is not usually suitable The newly added data cells in the Root item are placed at the beginning of the tree while items into which we want to move these cells are in the bottom part of the tree The whole expanded tree is soon hard to read Method No 2 recommended Click on the Root item by the right mouse button and select Open Data Cells from the menu Only the Root branch with its data cells is expanded
59. edure of Adding New Measurements to adi Configuration File 44 Restructuring of Template DB Database Tree area 45 IREN A O 48 Starting of TCG Editor Software erre ao aaea nena nenas 48 Creation of First New Reduction ooooconncnninnccnnnccnncconnnccnconccconcnn nan nnnnnnccnrcannnrnnnnncrnnrnrrnannn 49 Reduction IntervalS ici ici ae eiea lac teen abet enti anne teas 50 Max Dilution Parameter of Data Dilution seara 52 Significant Change of Static Data eee cece ceee eens eens eeeeeeeeeeeeeeeeeseeeesaeesaaeseaeesaeeseeseeeaaes 53 Storing Reduction in tcg FilB oonncconnndinncninncnnnncconn cnn cnn cccnn rca 54 Creation of Another Reduction art cnn rca 54 Change of Reduction Parameters renina reaacerareaa nina neraneraaa 56 Change of Reduction Name ste errareraneraaeaaaaa rena rara nara nera netas 56 Creation of First New Normal TCG rr rareaaaaana nene aaar aa aaarna nana 57 Saving of TCG Definition in tog File ereta eretas 61 Creation of First New Abnormal TOG cccccceceeeeceeeeeeeeeeeeaeeeeaeeseeeeseaeeeeaaeseeeeeseaeeeseaeeseaeeteaes 61 Entering of Name and Creation of TOG Frame eterna 63 Abnormal TCG Control Quanntity ceecceceeeeeeeeeeeeeeeeceeeeeeeaeeeeaeeseaeeeseaeeeeaaeseneeeseaeeesaeeneneeeeaes 64 Adding rot M
60. en 900 RPM to 1200 RPM Decrease of the speed under 900 RPM or increase above 1200 RPM represents an extraordinary event Decrease of the speed under 600 RPM or increase above 1500 RPM represents an emergency We require the new TCG to be running during both extraordinary and emergency operations Click on Edit for TCG Control Measurements List The edit window for the TCG Control Measurements List opens This window is very similar to the edit window for the TCG Measurements List editing which we have seen and described in detail during creation of a Normal TCG xi M TCG Control Measurements List TCG Ini File Loader Ini File fe Program Files Adash MMS6850 DEMO_MMS DEM C Program FilestAdashiMMSBSSOADEMO MM M Registered Control Measurements List _ m Available Measurements List Y 6110 1 Smax Y 6110 1 Val A Y 6110 1 Val B lt Y 6110 1 GapA E Y 6110 1 Gap B gt 6120 1 Speed Y 6120 1 ValA Y 6120 1 Val B Control Parameters VL unit L unit H unit YH unit M Parameters The whole right hand side of the window i e Available Measurements List and Parameters is identical with the previously described one in editing of the TCG Measurements List The upper half contains a list of measurement that can be selected as control quantities Only static measurements can be assigned as the control quantities therefore the list does not contain
61. ents List 6110 1 Speed 4 6110 1 Smax Y 6110 1 Time B Y 6110 1 Val A E 3 a pios ne 1 Orda al Br101 Orde 8 inicia Y 6110 1 4ps A M 6110 1 Gap B Y 6110 1 Aps B Y 6110 1 Center Line AB x M Parameters Save Close Click on Save to store the changes into the tcg file Then close the TCG Measurements List edit window by clicking on Close and you will return back to the window for work with TCGs All the newly added measurements have the y in front of their names This signals that the measurement is not halted in the TCG The checking field can be edited in the Registered Measurements List and you can suspend any measurement by clicking on it ATTENTION If a measurement is registered in more TCGs and should be suspended in one or more TCGs then a suitable place to do it is here The measurement will stay active in the remaining TCGs Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 61 A3750 its data will continue to be transferred by the Data Admin service from the Online DB to the DDS DB so they will not accumulate in the Online DB However if the measurement should be suspended as such then it is better to suspend it through the parameter status in the Idi file In this case the Data Loader service will not transfer the suspended measurement
62. es not have to be defined for a reduction 3 Long time reduction Significantly reduces measured data and significantly decreases their volume This interval does not have to be defined for a reduction Each reduction always has an interval of the last stored data without reduction It is possible to switch on the short time reduction long time reduction or both the most common case for older data The intervals are defined in days by entering values into To fields as is shown on the following pictures Long time Reduction Space Short time Reduction Space No Reduction Space lt From No Reduction Value Short time Reduction Value Long time Reduction Value The Oldest Data The Newest Data Now Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 51 A3750 Short time Reduction Only Check the Short time Red field The To field gets enabled for entering the No Reduction interval end which is also the beginning of the From interval of the Short time Reduction The To field that defines the end of the short time reduction will stay disabled since the short time reduction will be applied all the way to the oldest data The picture shows a situation when there is no reduction of data for 7 days All the data older than 7 days are reduced according to parameters of the short time reduct
63. file unless these paths are standard see Alternative Path further computer name and instance of OPC server used on this computer o predefined computer name is in following format A3716_XXXXXX where XXXXXX stands for serial number of the A3716 rack this information is on the of rack o on A3716 the OPC instance is AOPC_A3716 Procedure to create a new project 1 Entering of a project name PrjName From it are derived Data Loader project name to register Data Loader service Data Admin project name to register Data Admin service Project configuration file name PriName dmi Data Loader configuration file name PriName ldi Data Admin project configuration file name PriName adi TCG definitions file name for Data Admin PrjName tcg Online DB name PriName online The user must name only Normal DB and Template DB If the names of these databases were tied to the project name it would preclude use of the same Normal DB for more monitoring systems i e a possibility of data collection from more OPC interfaces Such limitation is not desirable 2 Assignment of OPC server name of a computer where is the OPC server installed A3716 SerialNumber instance of the OPC server on the chosen computer AOPC_A37160 3 Setting of parameters for SQL server and creation of empty Online DB ATTENTION name of a computer where the SQL server is installed instance of the SQL server on the chosen computer
64. formation consult www adash net www adash eu ADASH Ltd 6 A3750 A3716 and A3750 A task of A3716 is to measure analogue signals from protection systems or from directly connected sensors The protection system usually does not store the measured and consequently analysed values but overwrites them in the memory by new ones after the analysis If the user wants to use the measured values for a predictive maintenance control the additional product must be used usually called a Monitoring System This system continually stores the measured values into a computer where they are prepared for further processing We have developed the online monitoring system A3750 with the 16 channel parallel dynamic signal acquisition unit A3716 What properties do we expect from the continuous storing of the measured data To start the user usually answers that he would want to store all the measured data However this means that we would need to store very large amount of data approximately every second If we calculate the volume of this data for just one day we shall find out that such database shall have several gigabytes This is not acceptable even today when sizes of hard disks are sufficient This size is not our limiting factor however The actual limitation lies in a time demand for processing of such a large database since the processing of the large database is much slower than of a small one Therefore we need to reduce the data and
65. g to switch the editor to the work with TCGs mode The TCG List with all so far defined TCGs is located in the upper part of the newly opened window In our case the list contains only one item with the name 6110 1 Normal Static If it is not selected click on it Then click on Copy and a dialog to enter a name will appear Fill it with the name 6110 1 Abnormal Static and confirm with OK A new item created by copying of the original TCG appears at the end of the TCG List Thanks to this the TCG Measurements List which we inherited from the Normal TCG is filled for the new Abnormal TCG Tcg Editor x M TCs TCG Ini File fe Program Filest dashiMMSBSSOADEMO MMSADEMO MMS tcg TCGs List 6110 1 Normal Static TCG Measurements List 6110 1 Speed 6110 1 Abnormal Static 6110 1 Gap B New Rename Coy De Edt JL Te gt TCG Parameters 17 TCG Control Measurements List I Abnormal M TCG on Period o CH Pretng Doi min Pong fO tm Reduction wek S Save Edit Close Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 64 A3750 We are going to fix the following items in the TCG Parameters group Check the Abnormal field This will make the fields Pretrig and Prolong accessible Put 20 into Period Put 2
66. he Online database For analysing of the data stored in the DDS databases we need another software which is not a part of the A3750 monitoring system It is a universal software to archive visualise and analyse data measured by both manual instruments and online measuring systems DDS software to visualise and analyse data stored in the DDS databases The A3750 uses support of some other software for its work Although their installation is not a subject of this chapter they are necessary for its work and the A3750 will not work without their previous installation and activation on a computer They are these software SQL Server Software for work with SQL type databases OPC Server Software to transfer data between A3716 measurement system hardware and the PC where should be the A3750 monitoring system installed Working Directory Data Admin and Data Loader which are the backbone of the A3750 monitoring system are not common software but services Thanks to this they are capable of running immediately after starting a PC before any user logs on the system This characteristic ensures that after a PC is restarted for example after a power outage work of the A3750 monitoring system starts automatically The services however have certain limitations that must be respected One of them is the need to be registered on the PC This is automatically done by the A3716 Setup software which registers both services during a start up of a ne
67. heir reports The services do not have any user interfaces Their work can be monitored only through the Data Status software which is a part of the A3750 monitoring system and in case of a defect the reports written in the log files can help to find it During creation of a new project the A3716 Setup creates a subdirectory in the working directory with a name of this project the picture shows the name PrjName and places all the project configuration files in it i e files with dmi Idi adi and tcg extensions C Program Files Adash A3750 PriName PriName adi DataAdmin exe PriName dmi DataAdminProjectEditor cfg PriName di DataAdminProjectEditor exe PriName tcg DataLoader exe A3716Setup exe TCGEditor cfg TCGEditor exe Adash subdirectory not file underlined PriName PriName adi is not created during installation but after start of some software italics DataAdmin exe part of installation in bold letters Licences For protection of our software we developed the system of Licences These Licences licence files or aky files are bound with hardware protection key called HASP That means if you want to run the A3750 software you need the HASP key and a licence files for this particular key the licence files cannot be used with any other HASP key Protected programs are DataLoader can connect only the OPC servers that are specified in the licence file Licence name DataLoader aky DataAdmin can transfe
68. hout regard to size of operated projects The whole computer should be reserved only for operating of A3750 monitoring system including all of its possible expansions New hardware should be used with a new installation of the operating system When you install the operating system install only parts that are necessary for using the A3750 monitoring system Install only software that are necessary for operating the A3750 monitoring system and software necessary for setting and testing of hardware operation of the A3716 measuring system Limit number of concurrent users that can access the SQL server from the outside through a network to a necessary minimum in SQL server settings They are users of DDS software processing of DDS database data and Data Viewer online visualisation of selected data from the Online DB A large number of users simultaneously accessing the databases can overload the SQL server and slow down the system Hardware Hardware requirements depend on data collection requests for a specific project The system load depends primarily on these parameters Online database history length see parameter Online History in the chapter Data Admin Project Editor frequency of data transfers from the Online DB to the DDS databases see parameter Transfer Period in the chapter Data Admin Project Editor amount of data in the DDS databases We generally recommend two core 64 bit processor minimum of 1 GB R
69. ick on 6110 7 and then press Insert on the keyboard We shall see the familiar dialog window for creation of the new item again Create all items the same way as you created the 6110 1 during the last step DDS2007 DEMO MMS template Database Trees Resources Tools Window Options Help JF MEYE ZA Y Machine Cell Item Cell View Scheme Instrument 6110 1 Speed 6110 1 Smax 6110 1 Val A 6110 1 Val B 6110 1 Gap A 6110 1 Gap B RB 6110 1 Time A GB 6110 1 Time B EB 6110 1 Orbit AB uu 6110 1 Orda A WW 6110 1 Orda B 6110 1 Aps A 6110 1 Aps B 6110 1 Center Line AB mS 6110 1 iS plate DEMO_MMS_tem Moving of Selected Data Cells The Speed Smax Orbit AB and Centre Line AB data cells should be moved from the Root to the Common item Click on the first selected item in this case Speed Press Ctrl on the keyboard and keep it pressed Add other items by clicking on them Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 42 A3750 DDS2007 DEMO MMS template Database Trees Resources Tools Window Options Help SIE ELS E Machine Gell Item ell cheme Instrument 6110 1 Val A 6110 1 Val B 6110 1 Gap A 6110 1 Gap B GB 6110 1 Time A BB 6110 1 Time B WW 6110 1 Orda A bu 6110 1 Orda B 6110 1 Aps A 6110 1 Aps B MES 6110 1 MID common c
70. ing of Measurement in List In the chapter Creation of First New Normal TCG we have already recognised in the Registered Measurements List and Available Measurements List descriptions that measurements specified in both lists can be temporarily suspended The description on how the process of suspending works is shown there We will only state this information more precisely in this chapter The picture represents a situation when the static measurements Gap A and Gap B are suspended in the TCG with the name 6110 1 Normal Static We can see it on the status of checking fields on the left of the Registered Measurements List On the other hand the dynamic measurements Time A and Time B are suspended in the whole Data Loader project We can see it on the y signs at the right hand side of the Available Measurements List Now we will explain differences of these two types of interruptions Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 70 A3750 TCG Name 6110 1 Normal Static E xi gt TCG Measurements List TCG Ini File Loader Ini File C Program Files Adash MMS6850 DEMO_MMS DEM C Program Files Adash MMS6850 DEMO_MMS DE M Registered Measurements List 7 m Available Measurements List M 6110 1 Speed 6110 1 Time A a W 6110 1 5 6110 1 Time B a E ge Y 6110 1 Orbit AB
71. ion All the data older than 90 days are reduced according to parameters of the long time reduction From To No Reduction Now 30 days Short time Red v 30 30 days Long time Red V so days Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 52 A3750 Max Dilution Parameter of Data Dilution A data reduction in its final result presents dilution of the succession of the originally more often measured and stored data In no case however it is just mere time dilution which could cause that significant data which by accident fell into a dilution interval would be removed or lost That is why also other parameters exist from the time dilution point of view that qualify a possibility of removal of a measured value from the data succession as a consequence of the reduction In a simple case it would be sufficient to define the interval which should remain in the data after the reduction and all the data within this interval would be removed However with regard to other criteria limiting the possibility to remove any data within this time interval we cannot require keeping of the identical interval between the reduced data For example if all the data inside of the just reduced interval are significant then the reduction algorithm must keep all of them Such data interval must then
72. ion The long time reduction will not be applied to any data From To No Reduction Now 7 days Shorttime Red M 7 fo days Long time Red To days Long time Reduction Only Check the Long time Red field The To field gets enabled for entering the No Reduction interval end which is also the beginning of the From interval of the Long time Reduction The To field that defines the end of the long time reduction will stay disabled since the long time reduction will be applied all the way to the oldest data The picture shows a situation when there is no reduction of data for 15 days All the data older than 15 days are reduced according to parameters of the long time reduction The short time reduction will not be applied to any data From To No Reduction Now fi 5 days Shorttime Red To days Long time Red V f 5 fo days Short time and Long time Reductions Check the Short time Red field The To field gets enabled for entering the No Reduction interval end which is also the beginning of the From interval of the Short time Reduction Now check the Long time Red field The To field gets enabled for entering the Short time Reduction interval end which is also the beginning of the From interval of the Long time Reduction The picture shows a situation when there is no reduction of data for 30 days All data older than 30 days but not older than 90 days are reduced according to parameters of the short time reduct
73. ion signal that does not requires any deep knowledge of the whole system This interface is called A3716 Signal Analyser It is accessible directly on the A3716 rack If the A3716 has attached usual computer accessories Monitor keyboard mouse then you can log into the computer as user remote or if the A3716 rack is connected through network you can log in from other computer using Remote desktop RDP On the desktop you will see the small program A3716 Server Interface In this program you can initiate the A3700 Signal Analyser Warning A3716 Signal Analyser requires that A3716_MeasEngine software is not running this means any projects collecting data from this particular A3716 will be stopped When you stop working with the A3716 Signal Analyser start the A3716 again A3716 Server Monitor Is a program intended to ease running A3716 Signal Analyser and basic system diagnostics On the top of list is the instrument A3716 and below it there is a list of measuring cards with their status indicating basic problems overload icp problems hw problems To start the Signal Analyser first press Stop button this stops A3716_Server and A3716_MeasEngine Now A3716 cannot be configured remotely with A3716 Setup After the measuring is stopped you can run A3716 Signal Analyser After you exit Signal Analyser press Start button to start A3716_Server and A3716 again Adash Ltd Czech Republic Tel 420 59 6232670 Fa
74. ires a different type of a data collection just the one we have mentioned above the second level collection with no or little reduction The measurements that are used to control i e start or stop the data collection on the second level we call the CONTROL MEASUREMENTS Normal and Abnormal Machine Operation We mark a machine operation as Normal if all control measurements have acceptable i e normal values If at least one control measurement acquires unacceptable values we call the machine operation Abnormal Grouping of Measurements Once you start creating projects you shall find out that all measurements you want to monitor fall into many groups A basic property of each group is whether it contains measurements only for a normal or only for abnormal machine operation Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 12 A3750 Characteristic signs of each Normal group are the same data storage time period for example 5 minutes a level of used reduction Characteristic signs of each Abnormal group are the same data storage time period for example 5 seconds a level of used reduction a list of control measurements acceptable values for each control measurement how much data is stored before the origin of an extraordinary event the
75. ities on the second level We have explained that the fast collection starts when some measured value is not acceptable However there is a reasonable requirement that we would like to have the fast collected data for the time before the origin of the unacceptable situation Even this the A3750 can handle thanks to a special circular memory that stores ALL available data This memory contains the last several hours of the measurements in full definition The process of data collection then can load even the fast data retroactively We have described the collection of data on two levels very generally Now certainly there shall appear questions like Can every measured quantity start the second level data collection How are the acceptable intervals defined How does the data reduction procedure work All characteristics of the data collection and reduction can be set based on real life requirements We shall explain this in detail in the following text If the data are stored in the databases they are prepared for further evaluation and they can bring much more information about status of the monitored machinery to the user This information is not Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd Eus A3750 available and really it is lost since the protection system is used only wi
76. itten Since we have created the new branch 6110 1 in the restructuring the editor informs us that the new data cells can be found in the Root item 3 Confirm this information and the new information about the first found new measurement will be written x 6120 1 Speed New measurement has been found Register it and create a new DB cell No The new speed measurement was found first There is no database cell in the Template DB nor database connection in the adi configuration file for it the measurement is not registered By the Yes and No buttons you can select which measurements will be added Clicking on All adds all the newly found measurements together ATTENTION If you do not add one of the measurements and then do not remove it from a Data Loader service sub project the measurement data will accumulate in the Online DB with all negative consequences which were described before 4 Clicking on All adds all the newly found measurements together Then the information about the number of the added measurements will be written Speed Val A Val B Time A Time B Orbit AB Orda A Orda B Aps A Aps B Information 8 86 lx 1 10 cells has been successfully added 5 Confirm the information Now the new measurements are added in the adi configuration file and the root of the Template DB database tree If you do not like this database tree arrangement start the DDS and perform restructuring of the tree a
77. min service Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 19 A3750 It is an output of the Data Admin Project Editor software A Data Admin does not work without it It is an input of the TCG Editor software tcg File TCG and Reduction Definition File for Data Admin TCG Ini File This is a TCG and reduction definition file to set the Data Admin service It is an output of the TCG Editor software A Data Admin does not work without it Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 20 A3750 A3716 A task of A3716 is to measure analogue signals from protection systems or from directly connected sensors Practically it consists of fast computer with specialized HW for measuring and software for collecting the data A3716 HW 2 3700 Dimensions Standard 2U rack Inputs 4 measuring modules A B C D 16 channels AC 16 channels DC Each module contains 4 AC channels with optional ICP powering 4 DC channels Tacho The AC inputs measure max voltage peak 12V 24 bit A D conversion The DC inputs measure max 24V 12bit A D conversion Tacho input max 10V above 10V the signal is limited ICP powering 18 20V 3 8 mA can be enabled
78. n Save and this will enable Edit for the TCG Measurements List Edit for the TCG Control Measurements List will stay disabled since we are creating a Normal TCG Click on Edit and this will open a window to edit the TCG Measurements List xl M TCG Measurements List TCG Ini File Loader Ini File EXProgram Files Adash MMS6850 DEMO_MMS DEM je Program Files Adash MMS6850 DEMO_MMS DE M Registered Measurements List 7 Available Measurements List Y 6110 1 Smax Y 6110 1 Val A Y 6110 1 Val B lt Y 6110 1 Gap Y 6110 1 Gap B gt Y 6110 1 Time A Y 6110 1 Time B y Parameters type 5TAT unit rpm id 1 Save Close The left half of the window shows a list of measurements included in TCG It is marked as Registered Measurements List In our case it is yet empty Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 60 A3750 The right half of the window has the list of all available measurements which can be added into the TCG It is marked as the Available Measurements List Items that have the Y mark in front of them have the status_on parameter set in the Idi configuration file and are transferred from the OPC interface to the Online database by the Data Loader service The measurements which do not have this sign on front of their names
79. n the Max Dilutions group This interval is entered in seconds and is different for long tome or short time reductions and also usually for static or dynamic measurements We normally select smaller level of data reduction i e shorter interval for the short time reduction than for the long time one On the other hand we usually dilute dynamic data far more than static ones Max Dilutions Statics Dynamics Short time s 50 300 Long time s 500 1 4400 Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 53 A3750 The picture shows a situation where we want the interval between measurements no smaller than 1 minute 60 seconds for static data after short time reduction while for long time reduction we are satisfied with 10 minutes 600 seconds We select larger intervals for dynamic data We request the interval after short time reduction at least 5 minutes 300 seconds after the long time reduction we are satisfied with the interval of 4 hours 14400 seconds Significant Change of Static Data During the dilution of static data the significance of the measured data beyond the time view must also be applied If we did not introduce this parameter we would be removing important data for possible further analysis during the data dilution The important indicator of the static data sig
80. nal ground to trigger signal ground Front panel contains Power switch Hard Disc Drive indicator System reset button Status indicator for each measuring module and channel indicator Ch1 16 for each measured channel A status indicator should be green If it is red license checking or measuring module hardware failed A channel indicator should be also green when channel is in use If it is red it indicates ICP powering error broken cable or sensor sensor not connected Status 6h9 Ch10 Chti Ch12 o o o o o Status Ch13 Ch14 Ch15 Ch16 o o o o Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 22 A3750 A3716 SW Simplified scheme HW Modules l Configuration A3716_MeasEngine Data A3716 Server AOPC A3716 A3716 Setup DataLoader System On A3716 is installed Windows so the entire measuring process can be easily monitored and maintained with standard equipment like RDP Manufacturer setup LAN o The computer has pre set name A3716 SERIALNUMBER o IP Address 192 168 1 xxx o Subnet 255 255 255 0 USERS o Predefined user OPC for OPC DCOM purposes o Predefined user remote with password remote A8716 Software o Placed in c A3716 folder o Consist of A3716 MeasEngine A3716 server and AOPC_A3716 A3716 Folder structure C A3700
81. nfiguration into script a37 stops A3716 MeasEngine and OPC interface and starts A3716 with new configuration As a service it has some advantages and disadvantages The advantage e g is can run when no one is logged into the windows Disadvantage is that the program must be registered into system before it can run There is a simple command line program created for registering A3716 Server into system called A3716 Reg exe A3716 Reg exe must be placed in the same folder as A3716 Server A3716 Reg parameters register registers A3716 Server exe into system unregister unregister A3716 Server exe from system start starts A3716 Server service stop temporarily stops A3716 Server service AOPC A3716 Is a program providing standard OPC interface between A3716 MeasEngine and any OPC Client It communicates with the A3716 MeasEngine through shared memory and DataLoader through network In one system can run multiple instances of AOPC_A3716 Like A3716 Server this program is not usual program but the DCOM object But unlike A3716 Server it can register by itself It can be registered in command line by calling the AOPC_A3716 exe RegServer Usually we need to register the OPC server only once on the fist system installation But because we need OPC server to communicate through network we must set the rights for this DCOM object in the system One of key features of A3750 system is that A3716 provides interface for quick analysis of vibrat
82. ngle of sensor see picture bellow Usually used for proximity sensors or a5 ane Ne ap ag o a gr y a PEE O ze 1357 135 Sensor angles examples DC Sensor Properties Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 34 A3750 3 Sensitivity mV g Q Offset mV Unit Position DC sensor properties are similar to AC sensor properties The only exception is parameter Q Offset The value on this sensor will be calculated as Input Sensitivity Offset Tacho Properties lol Tacho Trig Level V 1 Trigger Tacho x _ Camel Trigger freerun taking of measured data begin immediately after preparation without waiting for anything tacho the taking of measured data begins when the external signal voltage level higher then defined Tacho Trig Level appears on the trigger input Tacho Trig Level V see previous section tacho Creating the measurements list Adding a new measurement into a list is a basic activity The procedure is the same as with all the measurement types We shall show the procedure on the adding of the TIME measurement type in the further text After the setting of sensors is done move to next tab Measurements To add new measurement click Add button In dialog box Add measurements to select app
83. nificance is an amplitude of the measured value There are three types of amplitudes absolute relative with regard to some reference value relative with regard to a previous value remaining after reduction If we have a chance to assign a reduction to each measurement then we can apply all three views to the measured value However this is not our case With the A3750 monitoring system we assign a reduction to the whole TCG And we can introduce measurements of different quantities into one TCG i e measurements whose results are in different units We would be hard put to define an absolute limit which would satisfy measurements of acceleration velocity displacement and speed at the same time We would have the same problem if the limit would be defined relative to some reference value Only if we define the limit relative to the previous value left after a reduction we can find an agreement unless we introduce completely incommensurable quantities into one TCG For example if a change of the monitored equipment speed is significant in the amount of 5 and significant change of vibrations is significant at 30 then it is not suitable to apply the same reduction to the both sets of data Relative Change We can understand the relative change of 30 of the 1500 RPM measured value in two ways 1 the change of 30 which corresponds to 0 7 1500 1050 RPM and 1 3 1500 1950 RPM 2 the change to 1 1 3 1154 RPM and to
84. ns and reductions of the Data Admin service This file is an output from the TCG Editor software Detailed description of individual fields and buttons is shown in the Level 3 During normal work with a project when the editor has been started from the A3716 Setup Data Admin Setup software you do not have to select any files since the names of all three files are transferred to the editor There is the Edit group on the right side of the window whose buttons we use to select whether we want to create or modify the reductions used by the Data Admin service or if we want to define or modify TCGs TCGs after you click on this button the editor goes into the TCG creation or modification mode Reductions after you click on this button the editor goes into the data reduction definition creation or modification mode Exit finishes the software If the TCG Editor was started from the Data Admin Setup software you will return back to the Data Admin Setup dialog window Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 49 A3750 Creation of First New Reduction If you do not require to use reductions in your work with the Data Admin service you can skip this chapter over However usually it helps to use the reductions in order for the DDS databases especially the Normal DB not to increase to
85. nter the name Usual and confirm it by OK The copy of the selected reduction will be placed to the end of the list under the entered name E Reductions TCG Ini File EProgram Files Adash MMS6850 DEMO_MMSSDEMO_MMS tcg M Reductions List Reduction Parameters Weak Name Usual From To No Reduction Now so days Shorttime Red V EN so days Long time Red M so fe days M Max Dilutions Statics Dynamics Short time s feo 300 Long time s eoo fr 4400 Levels of Static Value Change Realtive 2 Short time fo Realtive Long time ao Rename Delete Close Save save as New Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 56 A3750 Now modify parameters Max Dilutions and save the new reduction into the tcg file by clicking on Save Change of Reduction Parameters If you change parameters of any reduction you will be able to see the changes only after restart of the Data Admin service which will read in the tcg file with new parameters after starting By clicking on Reductions in the main editor window you will switch the editor into a mode of creation of new reductions and modification of parameters of already existing reductions In the chapter Creation of First New Reduction we have become familiar with all re
86. o much If you are going to use any reductions in the TCG definitions then you need to create definitions of these reductions before their first assignment to TCG That is why the chapter on definition creation precedes the chapter on creation of TCGs By clicking on Reductions in the main editor window you will switch the editor into a mode of creation of new reductions and modification of parameters of already existing reductions The left side of the window has a list of reductions defined up to this point Parameters of a selected reduction are shown in the right side of the window 4 m Reductions TCG Ini File C Program Files Adash MMS6850 DEMO_MMS DEMO_MMS tcg Reductions List Reduction Parameters Name From To No Reduction fr ow days Shorttime Red JT days Longtime Red M days Mag Dilutions Statics Dynamics Short time s Long time s Levels of Static Value Change Realtive Short time Realtive Long time Jl Delete Close Clicking New invokes the dialog to enter a reduction name A new reduction will be put into the list and assigned to the TCG definitions under this name EE Enter a new reduction name 1 x Name Weak OK Cancel The entered name must not exist in the list already and it is not possible to enter the reserved name No Reduction Enter the name of the reduction and confirm it by
87. ore TOGS irri aaa aar a aia 67 Changeoft TCG Parameters sucios e o aii enna E 68 Change ot TOG Name icono ia ati Dar RARE ERRE 68 Adding Removing and Suspending Measurements in TCG Lists 68 Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 4 A3750 How to Use This Manual A content of this manual is a complete description of the A3750 monitoring system The manual is divided into two difficulty levels for easier orientation Level 1 simply describes basic functions and does not dwell on details that are not important during the first reading After you read the first level you will gain necessary basic knowledge of A3750 behaviour and will be ready to read Level 2 Level 2 contains more detailed information about the A3750 We are focused primarily on information about its settings for practical operation After you finish the Level 2 you will be able to install and set the A3750 on your own in such way that will provide you with required data Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 5 A3750 Level 1 Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact in
88. ovided by a person who installed the SQL server Database Administrator Example SQL Server local SQL server on a local computer User sa system administrator Password adash password adash 2 Computer name and instances of used OPC servers A3716 racks Example Computer Name A3716 623178 name of an computer on which a selected instance of the OPC server runs Instance AOPC A3700 predefined OPC server on A3716 rack 3 Measurement list This is specification of required measurements from A3750 system and where they can be acquired A3176 rack and channels Example Wideband mm s 10 1000Hz on rack A3716 623178 channel A Spectrum g 0 25600 on rack A3716 623178 channel B1 Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 29 A3750 A3716 Setup This software is used for setting of A3750 general properties that will be used by all other software The services DataLoader and DataAdmin are registered and started from this software as well as the programs DataAdmin Project Editor and TCG Editor for setting the DataAdmin configuration Creation of New Project Registration of the project on your computer and definition of global project parameters creation of dmi file and definition of requested measurings This step is done in the dialog window of the A3716 Setup software and it is de
89. r into DDS only data collected from specified OPC servers Licence name DataAdmin aky DataViewer DDS2010 because they are not the essential parts of A3750 monitoring system and are can be ordered separately they are also protected by licences Licence name DataViewer aky and DDS2010 aky The licence files are placed in the same folder as the protected program If you want to change licence e g add a new A3716 into system contact us and we will send you new licence file typically in email And that is all The monitoring system is now prepared to create the first project on your PC In the next chapters you will find out how to create it Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 28 A3750 A3750 Project Under this term we understand a summary of all parameters according to which a A3750 monitoring system operates These settings are stored in several files with the same names but different extensions The files are in a text format it is possible to read and edit them with other software but we recommend using our programs Editors to avoid problems Information Necessary for Creation of New Project In order for the user to be able to create the new project user must have the following information 1 Instance of used SQL server username and password This information was pr
90. r the term measurement we shall thereafter understand all kinds of measurements available on the OPC interface We are going to divide the measurements to static and dynamic ones to easier understand the following explanation A static measurement is represented by one or several values only Examples are measurement of machine speed is a one value measurement measurement of a shaft position in a bearing Centre line is a two value measurement Aps measurement i e measurement of amplitude and phase on a machine speed frequency is a three value measurement The dynamic measurements are represented by an array of measured values for example time signals spectrum order analysis Control Measurements We are going to talk about significance of some static measurements in this paragraph Not all measurements available from the OPC interface have the same significance For example amplitude and phase values of the third harmonics are definitely less significant than an Smax value We understand higher or lower importance so that a change of the measured value is more or less significant for a total operational status of monitored equipment The important measurements primarily are Smax and machine speed For both of them it is very easy to determine value ranges acceptable for a good i e normal operational status If these measurements acquire unacceptable values it means an extraordinary situation Such situation requ
91. r whose creation and maintenance we have the TCG Editor described in the next chapter The Data Admin Project Editor together with creation and maintenance of the adi configuration file creates and maintains a common template of both DDS databases designated in this text as the Template DB Template DB DDS Databases Template The Data Admin service stores measured data into two DDS databases Normal DB is a database to which data according to parameters specified in Normal TCG are continuously stored during normal as well as abnormal operation of a monitored device Abnormal DB is a database to which data according to parameters specified in Abnormal TCG are stored only during abnormal operation of a monitored device The Data Admin service creates both databases as needed without user intervention as copies of the DDS database template called the Template DB This template is created and maintained by the Data Admin Project Editor during work with the adi configuration file The editor creates and maintains it itself without user intervention as a list of data cells in a root of a database tree Eventual structuring of the data cell list to the database tree branches is done by the user through the DDS software How to move groups of newly created data cells to individual tree branches the most easily will be described later in the chapter Restructuring of Template DB Database Tree In case that the Template DB and consequen
92. red machine Although the new adi configuration file of the Data Admin service and the new Template DB were created the Data Admin new project is not complete and therefore it cannot be started One last step remains to create a tcg definition file and assign measurements to the definitions How to do it is described in the TCG Editor chapter Maintenance of Existing adi Configuration File How to Add New Measurements to Project The most common modification of the adi configuration file is adding new measurements during expansion of a monitoring system 1 The new measurements had to be added to the Idi configuration file of the Data Loader service in order to be transferred by this service from the OPC interface to the Online database circular memory How to do it was described in the chapter Data Loader Project Editor 2 Now we need to add these measurements to the adi configuration file of the Data Admin service in order to create a database connection between the Online database and the DDS databases template for them New data cells in the Template DB need to be created for the measurements at the same time The Data Admin Project Editor working in the Add Cells mode will take care of it itself 3 At the end we need to add the measurements to the tcg definition file of the Data Admin service in order for this service to start moving them from the Online database to the DDS database This will be done in the TCG Editor Procedur
93. ropriate A3716 rack and press OK Edit the measurement settings and confirm the changes with OK Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 35 A3750 Measurement re Type j Channel Band fmin Hz Band fmax Hz Samples Avg Unit Now you will see the list of defined measurements EF A3716 Setup Project A3700 Test jolxi Project A3716 Sensors Measurements Filter fan 7 Advanced A3716_1 ch AC_A1 mm s TIME 10Hz 1000Hz tis s4096 AVG1 Total 1 Displayed in list 1 SN 00000X After you set all requested measurings save the project and start DataLoader now the data are being collected into the online database Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 36 A3750 Data Admin Project Editor An objective of this software is to let a user create and maintain a Data Admin service configuration file with adi extension easily This file contains a part of parameter settings needed for the Data Admin Especially it contains a database connection of the Online DB circular memory to both DDS databases Normal DB and Abnormal DB Remaining parameters are contained in a TCG definition set with extension tcg fo
94. scribed in this chapter Procedure to create a new project Press Create Project button and input the name of the project Fill Online DB Group boxes and press Create to create online database Fill the Meas interval and OPC interval boxes Next step is is described in chapter Adding new A3716 into system The descriptions of parameters are written below A3716 Setup No project TT Project Help Project A3716 Sensors Measurements M Online DB Online DB Name SQL Server Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 30 A3750 Parameters and Buttons of Online DB Group Online DB Name An Online database circular memory name is displayed in this information field The Online database helps the Data Loader service to create unreduced uncompressed data history The Online database name is created from the Project name by adding online The example on the picture shows the Online database name DEMO MMS online Under the term Online database we mean an ODBC source name under which the database is registered on your computer This registration is performed by the monitoring system itself SQL Server Write an instance of the used SQL server into this field If the SQL server is installed directly on your computer use the instance local
95. starts DataAdmin Project Editor and TCG button starts TCG Editor Their detailed description is below in chapters named after editors Adding new A3716 into system In the previous steps we defined for A3750 project where to store collected data in the next step we will show how to define where from we want to collect data 1 Open the project you want to edit 2 Move to second tab A3716 Project Help Project A3716 Sensors Measurements A3716 address a3716 623170 a3716 623170 43716 1 In A3716 address edit box input the network name or IP address of A3716 A3716 SerialNumber and press Add button The A3716 must be already present on the network A3716 Setup immediately checks if the A3716 is connected Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 32 A3750 Sensors When you connect the sensors to the A3716 rack you have to tell A3716 what kind of sensors you use This information is inserted into system in A3716 Setup in Sensors tab As we described above there are 4 modules A B C D and on each of them there are 4 channels AC DC and Tacho channel The A3716 Setup displays the sensors in a form of tree HE A3716 Setup Project A3700_Test Project Help Project A3716 Sensors Measurements A3716_1 MAC AC A1 ICP off 100mV g AC A2 ICP off 100mV g
96. t fulfil three conditions 1 A definition of this measurement must be performed in the Idi configuration file of the Data Loader service It will ensure that the Data Loader service will transfer data from the OPC interface to the Online database We have learned how to create the needed definition in the chapter Data Loader Project Editor 2 A new data cell must be created in the Template DB for the measurement This will ensure that the Data Admin service will be capable of creation of the corresponding data cell in both DDS databases in Normal DB and in Abnormal DB After this the database connection between the Online DB and DDS DB will have to be added into the adi configuration file of the Data Admin service for this measurement This will ensure that the Data Admin service will know from which Online database data cell to which DDS database data cell it should transfer the data We have learned how to create the corresponding data cell in the Template DB and its database connection in the chapter Data Admin Project Editor 3 The measurement must be entered at least into one active TCG definition in the teg definition set for the Data Admin service The Data Admin service creates a measurement table from the TCG definitions whose data it transfers from the Online database to the DDS database We will learn how to create the TCG definition and how to include requested measurements in it in this chapter Adash Ltd Czech Republic Tel
97. t history The values are shown in a well arranged graphical form A typical use of this is on a control station monitor where an operator continuously sees actual measured values together with information whether the values are acceptable or not The Data Viewer reads the data from the circular memory which means that it needs the Data Loader to run However it is independent from the Data Admin software Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 10 A3750 We shall often talk about the project in the following text Under this term we understand a summary of all settings according to which A3750 monitoring system operates These settings are stored in several files with the same name but different extension Other software that shall be described later are intended for easy creation of the mentioned settings Data Status It enables a user to follow work of the whole A3750 monitoring system A3750 Main Parts A3716 OPC data interface Rack Ethernet Data Loader Circular memory Data Viewer Data Admin DDS db SQL Database Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 11 A3750 Static and Dynamic Measurements Unde
98. taAdmin Project Editor software and includes configuration file of the Data Admin project with adi extension file of reduction and TCG definitions for the Data Admin with tcg extension creation of Template DB Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 17 A3750 Managing projects A3716 Setup Main parameters for A3750 are entered in this software The software also initiates other software and services This is the highest level for creation of a new project creation of a new Online DB creation of a dmi configuration file for the new project maintenance of existing projects intermediate control starting stopping of Data Loader and Data Admin services Creation of New Project in A3716 Setup A user creating a new project must have informations necessary to create every new project There are two types of this information 1 Information about installation of OPC and SQL servers 2 Necessary information about settings A3716 measurements ad 1 If the users do not perform these installations themselves they have to read the following information from the specification protocol computer name instance of SQL server used on this computer username and password to log on onto the SQL server directory path for placement of an Online DB and SQL server log
99. thout the tie in A3750 monitoring system So the A3750 can fulfil three at the first sight contradictory however at the same time legitimate requests of the user 1 Store suitably reduced measured data without excessive increase of a database volume on the long time basis 2 Collect and store measured data as often as to pick up even short term events that are important for further analysis and drawing of correct measures to protect the diagnosed equipment 3 In case of extraordinary situation store complete or little reduced data including the data measured before an occurrence of the extraordinary event Work of A3750 is divided into two stages to fulfil these requirements 1 Storage of complete data collected sufficiently often into the circular memory that contains the measured data for a limited time The circular memory enables access to the data that were measured before the extraordinary event The 24 hours history is usual size of circular memory 2 Storage and reduction of measured data The measured data are continuously stored at this stage with set reductions In case of an extraordinary situation complete or little reduced data are being stored Thanks to the circular memory it is possible to store even data measured before the occurrence of the extraordinary event Always Available Counselling for A3750 Directly from Manufacturer Reasons why use the A3750 monitoring system are clear You shall have your machine opera
100. tion under continual supervision and you can take advantage all available information for diagnostics If you know actual operational status of all your equipment you can efficiently plan its maintenance and lower costs Resources spent to buy the diagnostic system have very high returnability The A3750 monitoring system is designed to enable different kinds of user operations Typical cases for example are 1 The user is fully familiar with A3750 and uses it continuously and independently 2 A3750 runs without continuous analysis of stored data by the user In situation when unacceptable measurement values occur an external consultant is asked for a report The user may come in personally and perform the analysis in situ or user can do it remotely from the office The user always has all the necessary data available 3 The user does not have own workers to work with A3750 in spite of this requests regular diagnostic reports and recommendations Then the A3750 is operated remotely under direct manufacturer s supervision Nowadays when Internet is commonly available A3750 can be remotely supervised anywhere in the world Since this is a system that is constantly under improvement the manufacturer provides regular updates and upgrades that can be downloaded without charge on its web site We try to react quickly to your suggestions and include the improvements in a new version Cooperation with final users is without substitution for
101. tly also Normal DB and Abnormal DB satisfies you as a data cell list in the database tree root you do not have to worry about it It is hidden at a background of A3750 monitoring system work However this is good only for smaller amounts of stored measurements In case you have a large number of these measurements the list becomes hard to read and requires division into more branches of the database tree In this case you have to create and maintain this structure from the data cell list The Data Admin service always ensures after it is started that the new cells added to the Template DB by the editor will be created in the Normal DB also It will also at the same time ensure that the data cells that have been used so far and transferred due to restructuring of the Template DB database tree from one branch to another would be transferred identically in the Normal DB The Abnormal DB is being created by the Data Admin service always at the moment when the first extraordinary situation occurs according to the actual Template DB This ensures synchronisation of the database tree between the Template DB and both DDS databases A user does not maintain the Normal DB database tree User takes care of the Template DB database tree structure only Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 37 A3750
102. val VH Interval By checking the interval field we request the control quantity to be active provided its actual value falls into the checked interval By checking more intervals at the same time we can activate the control quantity in more intervals In the Available Measurements List click on the 6110 1 Speed measurement which should become the control quantity of the TCG that is being created Then click on The measurement will move from the Available Measurements List to the Registered Control Measurements List At the same time the text unit in the fields VL to VH changes to RPM since this unit was read from the Idi configuration file for the selected measurement Speed TCG Name 6110 1 Abnormal Static OS xi M TCG Control Measurements List 7 TCG Ini File Loader Ini File fe Program Files Adash MMS6850 DEMO_MMS DEM je Program Files Adash MMS6850 DEMO_MM M Registered Control Measurements List gt m Available Measurements List Y 6110 1 Val A Y 6110 1 Val B Y 6110 1 Gap lt noae Y 6120 1 Speed gt Y 6120 1Val A Y 6120 1 Val B M Control Parameters YL fo RPM L o RPM H fo RPM VH fo RPM Parameters vwu L H W Save Close Enter the limits that are specified in the task into the fields VL to VH At the same time check required intervals in which should the control quantity be activated Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59
103. w project ATTENTION Your computer operating system will register the services including their actual directory paths After the PC is restarted the operating system will look for the services at these paths to start them If you create a project and then move the A3750 directory someplace else on the disk the project will be visible and editable but you will not be able to run it lts Data Loader and Data Admin services will not run since they are not found on their original registered paths To ensure safe work with the services we have introduced the working directory in which key software of the monitoring system must be located Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 27 A3750 Structure and Placement of Working Directory We recommend that you name the working directory A3750 and place it on C disk as a standard to the directory path C Program Files Adash The working directory must have the following files installed in it Data Loader Data Admin A3716 Setup Data Admin Project Editor and TCG Editor After they are started The editors will create or look for their configuration files extension cfg in the working directory The Data Loader and Data Admin services will create their log files in the working directory extension log into which they will write all t
104. when it begins typically when nobody is using DDS Reductions per day set how often the reduction will be performed during the day E G when we set 2x the reduction will be every 12 hours Creation of New adi Configuration File and Template database It is apparent from the picture that if you start the editor from the Data Admin Setup software most of control buttons will be disabled and that most fields are already pre filled and their contents are not possible to change Save and Finish Clicking on this button will create a new adi configuration file in the New Project mode and a new Template DB at the same time Exit finishes the software If the Data Admin Project Editor was started from the Data Admin Setup software the software would finish itself after creation of the new project and you will return back to the dialog window Data Admin Setup Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 38 A3750 10x Ini Files Control of Reduction Loader Ini File First Reduction at Reductions per Day CNA3700DM detest detest Idi 00 x y Admin Ini File Limits C A3700DM dctest dctest adi Online History Max Normal DB Size 2 hous 4000 MB SQL Server Server Normal DB kaluza SqlExpress dctest User Template DB sa dctest template Password adash
105. x 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 24 A3750 43716 Server Monitor 13 03 12 Status updated A3716 Signal Analyser A3716 Signal Analyser is a program for quick signal analysis It has very similar interface to our VA4Pro instrument Here you can configure your own measuring set and see what is happening on the inputs on A3716 This data are not stored anywhere so you can experiment with the setup without affecting any projects running on this A3716 When A3716 Signal Analyser starts it loads the configuration from the last running project Adash Ltd Czech Republic Tel 420 59 6232670 Fax 420 59 6232671 e mail info adash cz For further technical and contact information consult www adash net www adash eu ADASH Ltd 229 A3750 A3750 Installation In this chapter we shall find out what kind of computer to use for operation of the monitoring system and how to install A3750 software on it simply Computer Requirements This chapter shows minimum requirements for hardware and software of a computer on which we operate the whole A3750 monitoring system These requirements cannot be universally prescribed Certainly they are going to be quite different in case that we operate one relatively small project on the computer as opposed to several large ones General Recommendations The following principles should be kept wit

Download Pdf Manuals

image

Related Search

Related Contents

LYNX Touch Security System  Sibelius User Guide  Manual de seguridad DP2K-E series    - National Instruments  Écrire le scenario d`exposition  Sony RMM-131 User's Manual  Bedienungsanleitung  59,9 cm - MEDION USA  0127-1650_2092 Fiber IFU_RevE_0310.indd  

Copyright © All rights reserved.
Failed to retrieve file