1. A TELEDELTA Operation and Installation Guide HDS2800 Series Encoder Modulator High Definition HD Digital COFDM MPEG2 and H 264 Modulator with IP Multicast 19 Rack Mount Revision 4 0 Firmware version Released File HDS2800 Rev 4 0 Docx HDS2800 Operation and Installation A TELEDELTA Contents TO TE 3 2 0 HDS2800 Rack and Wall Frames anian aeaaaee aeaa aaa a aeaa aAA 4 2 1 Indicators and Key buttons Details eee cccceeeeeeeeeeeeeee eee eeeeeeeeeeeeeeeeaeeeeeeaaeeeseeaaeeeseeseeseeeeeeneeees 4 ET te EE 5 3 0 Operation from the front Dame 6 4 0 Programming via inbuilt Web Server NMS operation ccccccsceeeeeeeceeeeeceaeeeeeeeseeeeeseaeeeeeaeeneneeees 7 4 1 Connection ANG Me UL DE 7 4 2 Input configuration Setting 2 20 cae ocean ehi R cared dine tore 8 4 2 1 Select the Input n setting 2 22 ceeeeesceceeeeceeeeeeeeeeeeeeeeeaeeeeaae cence seeeeesaaeseeaaeseeeeeseaeeesaeeeeneessaes 8 4 22 ASI INPUT SOTA ET 10 4 3 NIT table Seting ET 12 4 3 1 Add Set Edit the NIT table teisiin eaan aia a aa aaa i aaa aaea aaee 13 4 4 P Output Setting EE 14 4 5 Modulator Seting EE 15 4 6 Utilities Save Restore A 16 4 RODOOt TE 18 4B FUERE 18 TeleDelta is proudly an Australian owned company File hds2800 rev 4 www teledelta com Page 2 of 18 HDS2800 Operation and Installation A TELEDELTA 1 0 Key Features Transparent resolution pass through up to 1920x1080 and 1280x720 50P 60P 108
2. available on request TeleDelta is proudly an Australian owned company File hds2800 rev 4 www teledelta com Page 6 of 18 HDS2800 Operation and Installation A TELEDELTA 4 0 Programming via inbuilt Web Server NMS operation The inbuilt web interface allows fast setting of the units parameters The web interface is required for the setting of the LCN and NIT table as well as labelling the input for on screen display OSD 4 1 Connection and Login Connect a PC equipped with a modern browser to the NMS port The HDS can be connected with a straight through cable or via a hub switch Point your browser at the IP address for the unit The IP that is set for the unit can be read at LCD menu location 5 1 Hint To read the IP address from the LCD press Lock key to enter the menu tree and navigate to menu 5 1 A login interface will appear Both of the default user name and password are admin and are case sensitive AA PECE Usemame Password FS Login Hint To reset the username and password to default from the LCD press Lock key to enter the menu tree and navigate to menu 5 5 After login the Welcome system status screen will display gt D 19216815120 o A TELE Status input input2 Ast Modulator Tables Networking Utilities STATUS INFORMATION INPUTS INPUT 1 INPUT 2 Interface HDMI HDMI Bitrate 14 762 Mbps 0 000 Mbps OUTPUTS Max Output Bitrate 19 35
3. A 7 J Status Input 1 Input2 ASI Modulator TELEDELTA LOAD CONFIGURATION Load a saved device configuration Choose File No file chosen No file chosen FIRMWARE UPDATE Upgrade the device firmware to gain new functionality Current Software Version Current Hardware Version Current Web Version Choose File No file chosen No file chosen USER ACCESS Change the user name and or password for this Web Management Interface The username and password are case sensitive Tables Networking Utilities from a file Load Config 6 04 Build 129 Jan 7 2013 5 2 5 03 Current User Name admin Current Password New User Name New Password Confirm New Password Keyboard and LCD Lock A Labels Comment Load Configuration Load a saved configuration from file Firmware Update Update of existing firmware User Access Adjustment of login password and security details Backup Configuration Saves the current setup to a re loadable file TeleDelta is proudly an Australian owned company File hds2800 rev 4 www teledelta com Page 17 of 18 HDS2800 Operation and Installation A TELEDELTA 4 7 Reboot Click to initiate a re boot of the unit and the re load of the most recently saved settings see above REBOOT Reboot unit to apply major configuration changes 4 8 Firmware This function is used to upgrade the device s
4. and B If there are no existing table entry s add a new table with the following RF Frequency 550 500MHz Leave all other parameters as default and set the LCN s in ascending numbers E g 101 102 201 202 Refer to the next section for Adding setting editing the NIT table Update NIT click to update the NIT tables in system always do this after an update to the table Clear NIT click to remove all the tables that have been inserted before TeleDelta is proudly an Australian owned company File hds2800 rev 4 www teledelta com Page 12 of 18 HDS2800 Operation and Installation A TELEDELTA 4 3 1 Add Set Edit the NIT table Click Del A and Add to pop up a new table or Detail to show the existing table E HDS2800 Management Google Chrome Lo ji 192 168 15 120 SetNIT htm key AddTSLoop 255 0 NIT ENTRY a Transport Stream ID 0x0001 Original Network ID 0x0001 RF Frequency 550 000 MHz Bandwidth 7 MHz Le Constellation 64 QAM ls Hierarchy Informaion Not Hierarchy Code Rate 213 7 Guard Interval 1 8 v Transmission Mode 8K v 0x0101 51 T De 0x0201 EI E Det y y Pn m e Label Options Comment Transport stream ID Inherited 16 bit field label identifying the TS which contains the service event or mosaic described by the cell The default value is not normally changed Inherited from prev
5. available for the implementation of IP systems RENEE DEN MODULATOR WEEN TELE KI Status Input1 Input2 AS Modulator Tables Networking Utilities NMS PORT CONFIGURATION NMS Port Address 192 168 15 120 Subnet Mask 255 255 255 0 Gateway Address 192 168 0 1 Management Port 80 DATA PORT CONFIGURATION IP Output Enable NM Service IP Address 192 168 2 137 Output IP Address 224 2 2 2 Subnet Mask 255 255 255 0 Gateway Address 192 168 2 0 Port 1234 Note In this example if using VLC set the VLC network stream to udp 224 2 2 2 1234 and connect the stream from the DATA port ensure your computers firewall is either disabled or accepting of the above port address TeleDelta is proudly an Australian owned company File hds2800 rev 4 www teledelta com Page 14 of 18 HDS2800 Operation and Installation 4 5 Modulator setting V Status Input 1 Input2 ASI Modulator Tables Networking Utilities A TELEDELTA A TELE DVB T MODULATOR CONFIGURATION Bandwidth 7 MHz k Constellation 64 QAM a Transmission Mode 8K x Guard Interval 1 8 x Code Rate 2 3 X RF Frequency 550 000 MHz 30 000 1000 000 RF Output Level 10 0 dBm 30 0 10 0 Appi Label Options Comment Bandwidth User set the range is 6MHz 7MHz and 8MHz Australia is 7MHz Constellation User set QPSK 16QAM and 64QAM Use 64QAM Transmission mode U
6. latest software program Follow the instructions provided with the software updates TeleDelta is proudly an Australian owned company File hds2800 rev 4 www teledelta com Page 18 of 18
7. 0P 10801 and 720P resolution depending on input modules 1 or 2 input modules provide up to 4 inputs format and rate dependant Input formats HDMI HD SD SDI Composite PAL CVBS 576l resolution ASI Multiple outputs on coax as selectable COFDM DVB T MPEG 2 and H 264 as IP MPTS UDP Multicast as ASI Modular design select input modules to suit the application The HDS2800 series supports HDCP Channel naming installer selectable LCN s and DVB tables Front panel LCD or built in webserver Frame chassis options include wall mount 1HD or 2 SD inputs and rack mount options 2 HD and 4 Comp input channels High quality modulation MER gt 42 Output bandwidth fully adjustable up to 27Mbps Individual channel rate adjustment Selectable RF Frequency RF Power output FEC Guard Intervals Constellation HDMI modules auto switching provides redundant inputs Multiple HD SD channels can be daisy chained together to output as a single digital RF channel or can be spread over multiple RF channels The HDS2800 has an excellent cost per HD digital channel TeleDelta is an Australian owned company with local engineering and support facilities in Australia and New Zealand for more information please visit our website www teldelta com TeleDelta is proudly an Australian owned company File hds2800 rev 4 www teledelta com Page 3 of 18 HDS2800 Operation and Installation A T
8. 2 Mops Current Output Bitrate 14 810 Mops TS Overflow e RF Frequency 550 000 MHz RF Output Level 10 0 dBm As at May 2102 Google Chrome 18 0 1025 168 m and IE9 0 6 are known to work Goodness knows what the future will hold TeleDelta is proudly an Australian owned company File hds2800 rev 4 www teledelta com Page 7 of 18 A HDS2800 Operation and Installation TELEDELTA 4 2 Input configuration setting 4 2 1 Select the Input n setting A HDMI input card is shown below Vidoe Format Mpeg2 e Video BitRate 12 00 Mops Audio Format Mpeg2 e Audio BitRate 192 Kbps X Program Out Enable v Program Name HDMI Channel 1 Service ID 0x101 PMT PID 0x100 Video PID 0x101 Audio PID 0x102 PCR PID 0x103 Video amp Video Format 1920x1080 50i Encoding Bitrate 14 750 Mbps Rom Version 0 4 0 3 Heip Apply Label Options Comment Video format User set MPEG2 H 264 selectable video format on certain HD HDMI frames Video bit rate User set The range is 1 19 5Mbps Audio format bit rate Default The default value is MPEG2 and 128kbps and is not normally changed Program out enabled User set Turn on off program output Program name User set Enter the program name to be displayed on the TV a een Default System will automatically select the default values Encoding and video Indication only Green is normal Red is fault indicator
9. ELEDELTA 2 0 HDS2800 Rack and Wall Frames 2 1 Indicators and Key buttons Details Rack Mount Frame Wall Mount Frame LCD display NMS port access to internal management web server Power Indicator Channel Lock light s Up and down left and right button Enter button for confirm Menu button for back step Lock button press to lock unlock Data port IP multicast output D Alarm indicator N OONDOAW TeleDelta is proudly an Australian owned company File hds2800 rev 4 www teledelta com Page 4 of 18 HDS2800 Operation and Installation A TELEDELTA 2 2 Installation This section outlines some of the precautions users must maintain when installing servicing and operating the TeleDelta HDS2800 Series General Precautions Operate the HDS2800 in a dry dust free environment Unless qualified do not open the cover of the HDS2800 doing so may void all warranty purposes Exercise caution when operating any electrical device do not operate any device unless you are qualified to do so Do not stick your fingers into a light bulb socket TeleDelta is proudly an Australian owned company File hds2800 rev 4 www teledelta com Page 5 of 18 HDS2800 Operation and Installation A TELEDELTA 3 0 Operation from the front panel This version of the manual is intended for setup and maintenance of the unit using the NMS web interface For front panel LCD operation please refer to the LCD supplement
10. ious window Original network ID Inherited 16 bit field a label which in conjunction with the following fields uniquely identifies a service event or mosaic The default value is not normally changed Inherited from previous window RF Frequency Inherited Inherited from Modulator settings Don t change Bandwidth Inherited Inherited from Modulator settings Don t change Constellation Inherited Inherited from Modulator settings Don t change Hierarchy information Not used Hierarchy information this option only for ISDB T standard device Don t change Code rate Inherited Inherited from Modulator settings Don t change Guard interval Inherited Inherited from Modulator settings Don t change Transmission mode Inherited Inherited from Modulator settings Don t change Service ID Inherited Inherited from Input settings Don t change LCN logical channel User set Enter the logical channel number The LCN can number be added more than one by re clicking Add option TeleDelta is proudly an Australian owned company File hds2800 rev 4 www teledelta com Page 13 of 18 HDS2800 Operation and Installation A TELEDELTA Del clicking Del to delete the added LCN information k Save clicking Save to save the current NIT parameters Cancel clicking Cancel to exit the edit interface 4 4 IP Output Setting Follow the on screen help guidelines for setting the IP output configuration Separate documentation is
11. ital 1 Passthrough 37Two Multiplex Parse timeout 200 Seconds Label Options Comment x Select the carrier output channel for the multiplexed programs This Cupit An B Users selection does not exist for the HDS2800 single carrier units Passthrough Usor set If selected all the input programs will pass through without any changes Multiplex User set Enable mux to select which programs are passed through Refresh Input Click Click to re scan the input stream and rebuild program list Refresh Output Click Click to refresh the Output program list Select Program Click Transfers input programs marked with V to the output stream Cancel Program Click Removes output programs marked with V from the output stream All Input Click Selects all the input programs with one click All Output Click Selects all the output programs with one click Parse Timeout Default Time limitation to parse the input stream before TimeOut PID Pass Default Table is blank see details below TeleDelta is proudly an Australian owned company File hds2800 rev 4 www teledelta com Page 10 of 18 HDS2800 Operation and Installation A TELEDELTA e Click the PID Pass button to trigger a dialog box as below enter any PIDs required for pass through In some streams there are required PIDs which won t belong to any program Such as EPG amp NIT tables from here you can pass them through the multiplexing module without changing anything y HDS2800 Ma
12. nagement Google Chrome PID PASS Number Input PID Output PID Add 1 0x0018 0x0018 2 Del m m Gan Click Add to add more boxes for the Input amp Output PIDs then click Apply to confirm TeleDelta is proudly an Australian owned company File hds2800 rev 4 www teledelta com Page 11 of 18 HDS2800 Operation and Installation A TELEDELTA 4 3 NIT table setting The location of the NIT is defined in compliance with the ISO IEC 13818 1 1 specification but the data format is outside the scope of ISO IEC 13818 1 1 It is intended to provide information about the physical network Important Set the Modulator settings BEFORE creating a NIT refer Modulator section 4 5 below we Wf EH rn CES Jh d TELE Status Input1 input 2 ASI Modulator Tables Networking Utilities NETWORK INFORMATION TABLE Network Name My Network Network ID 0x0001 Transpor Stream ID 0x0001 Original Network ID 0x0001 NIT Version 0 LCN Standard European NorDig V1 J9 NorDig V2 ox0001 0x0001 550 000 7 MHz 64 QAM ys SE EI Update NIT Clear NIT An existing table entry The syntax and semantics of the NIT are defined as follows Defaults are shown above Network name The name of current network user can set as required Network ID This is a 16 bit field which identifies the terrestrial network that supports the service indicated The NIT table MUST be updated for both modules A
13. s HDMI input it Indication only Indicates if there is real time HDMI signal present Video format Indication only the current video format of the device Bit rate Indication only the current encoding bit rate Interface settings must be altered to reflect the input modules on the HDS 2800 For RCA modules the interface defaults to VGA this must be changed to RCA The aspect ratio for RCA input modules must also be changed to 16 9 Repeat the setup as required for all inputs fitted 1 4 TeleDelta is proudly an Australian owned company www teledelta com File hds2800 rev 4 Page 8 of 18 HDS2800 Operation and Installation A TELEDELTA TeleDelta is proudly an Australian owned company File hds2800 rev 4 www teledelta com Page 9 of 18 HDS2800 Operation and Installation A TELEDELTA 4 2 2 ASI Input Setting ASI Input If fitted the ASI option is fitted the ASI tab will display ASI input program information as below In this example an incoming ASI stream carries Seven Networks DTT formats as a 20 MiB stream Filtering is carried out to output only 7Digital and PID 18 Logout j sees anita I MODULATOR A TELE Status input 1 input2 ASI Modulator Tables Networking Utilities 1 INPUT ASI CONFIGURATION EN06 Set Tuner PID Pass INPUT PROGRAM Output A BO OUTPUT PROGRAM 17 Digital M17 Digital 27 Dig
14. ser set Use 8K Guard interval User set Use 1 8 Code Rate User set Use 2 3 RF Frequency User set Range is 30 1000MHz RF output level User set Range is 30 10dBm Set RF Frequency to 550 500MHz for Australian compatibility TeleDelta is proudly an Australian owned company www teledelta com File hds2800 rev 4 Page 15 of 18 HDS2800 Operation and Installation A TELEDELTA 4 6 Utilities Save Restore Follow the on screen help guidelines rR cca l L MODULATGR CA TELE d e Input 1 Input2 ASI Modulator Tables Networking Utilities SAVE BOOT CONFIGURATION Save modified parameters to the Boot Configuration Save Config RESTORE BOOT CONFIGURATION Load the last saved Boot Configuration Restore Config FACTORY DEFAULT CONFIGURATION Restore the unit to Factory Default Boot Configuration BACKUP CONFIGURATION Backup the current device configuration to a file Backup Config Labels Comment Save Boot Configuration Saves the current setup as the start up or restore settings Restore Boot Configuration Cancels current settings and restores the last saved settings Factory Default Configuration Resets all settings to factory defaults Backup Configuration Saves the current setup to a re loadable file Continued Below TeleDelta is proudly an Australian owned company File hds2800 rev 4 www teledelta com Page 16 of 18 HDS2800 Operation and Installation