Home

IRT-6080-DVS User Manual (Revision 00)

image

Contents

1. Slot 16 Multi Mode Switcher Slot 18 Multi Mode Switcher AM Slot 20 Multi Mode Switcher Product TAB Self explanatory Note that the Product Alias field can be set under the Configuration TAB setting Frame 50084695003 Slot 18 Multi Mode Switcher lt x Slot 18 Multi Mode Switcher Card state OK Connection ONLINE Produce Status Dipswitch Settings mielin eccmm ulti Vode Switcher Aaa IRT 6080 DVS Sa RT Electronics Board Rev 1 0 Software Rev Kill IRT Electronics Pty Ltd www irtelectronics com Page 21 of 29 Revision 00 IRT 6080 DVS Status TAB Status TAB shows the set input names corresponding to each input channel number these being set under the Configuration TAB in the second half of the DashBoard frame see next screenshot The input signal status is also shown In this example input 1 has a 2 97Gb s 3G rated signal present input 2 has a 270Mb s SD rated signal present this could correspond to either an SD SDI or ASI signal whilst inputs 3 to 8 do not have any valid input present Frame 50084695003 Slot 18 Multi Mode Switcher x Slot 18 Multi Mode Switcher Card state OK Connection ONLINE Product Sats Dipswitch Settings Input Monitor Input Channel Input Name Input Signal Status IRE IN2 IN3 IN4 IN5 ING IN7 INS Alarm Monitor General I O Alarm Priority Mode Alarm OUT A Alarm OUT B Alarm Priority Mode Warning Input Warning IRT Electro
2. SW11 7 Not Used SW11 8 OFF Front edge and remote panel switches switch immediately when pressed ON Front edge and remote switches must be held for approximately 2 seconds User s Choice before change in switcher state occurs N A Not Applicable if front edge and remote panel switches have been disabled for Tally indication only IRT Electronics Pty Ltd www irtelectronics com Page 9 of 29 Revision 00 IRT 6080 DVS 8x2 Router Quick Set up Guide Outputs A and B are independent from each other For push button switch control the IRT 6080 DVS must be used in conjunction with the optional 2 x 8 button IRT RC2 remote control panel Note that the IRT 6080 DVS s own front edge push buttons will only control O P A Without the optional remote control panel full 8x2 router operation is still possible via the DashBoard software control IRT 6080 DVS 8x2 O P A Local amp Remote Switch A Control O P B Remote Switch B Control O P A independent from O P B IRT RC2 Remote Panel DashBoard Control ees O P A Rate Set in conjunction with SW10 2 See page r SW10 1 OFF SW10 2 OFF User s Choice A SW10 2 O P A Rate Set in conjunction with SW10 1 See page 7 Ut Detect SW10 3 OFF 8 input mode SW10 4 ON 8x2 router mode O P A independent from O P B SW10 5 OFF Factory use only leave OFF User s Choice puso OFF Enable O P A front edge and O P A remote panel switche
3. OMDOOO oberr IRT 6080 DVS ELECTRONICS User Manual IRT Electronics Pty Ltd www irtelectronics com Page 1 of 29 Revision 00 IRT 6080 DVS 3G HD SD SDI ASI Digital Video Switcher Revision History Revision Date By Change Description Applicable to 26 09 2013 AL Original Issue Firmware Revision 3 0 IRT Electronics Pty Ltd www irtelectronics com Page 2 of 29 Revision 00 USER MANUAL Table of Contents IRT 6080 DVS Section Page Revision History 2 Operational Safety 4 openGear Introduction 4 General Description 5 Technical Specifications 6 Configuration 7 DIP Switch Settings 7 8x1 Switcher Quick Set up Guide 9 8x2 Router Quick Set up Guide 10 Dual 4x1 Switcher Quick Set up Guide 11 4x2 Router Quick Set up Guide 12 Installation 13 Signal Inputs amp Outputs 13 Remote Rear Assembly Wiring 13 HE 14 Connector Pin Assignments 14 15 pin D Connector Pin Assignments 14 9 pin RS 232 D Connector Pin Assignments 14 Front Edge LED and Switches Location 15 Rear Assembly Layouts 16 Operation 17 Single 8x1 Mode 17 8x2 Router Mode 17 Dual 4x1 Mode 18 4x2 Router Mode 18 Remote Control 19 IRT RC1 19 IRT RC2 20 IRT RP1 20 DashBoard Software Control 21 IRT 6080 DVS DashBoard Screenshots 21 Maintenance amp Storage 29 Warranty amp Service 29 This instruction book applies to units fitted with firmware Revision 3 0 IRT Electronics Pty Ltd www irtelectronics com Page 3 of 29
4. OUTPUT A and OUTPUT B are independent from each other when the IRT 6080 DVS is configured for 4x2 router mode of operation The switcher s inputs which are all reclocked can be configured for automatic rate detection which corresponds to rates at 3G SDI HD SDI and SD SDI ASI rates It is also possible to set the inputs to 3G SDI only HD SDI only and SD SDI ASI only rates Note that all inputs are set it is not possible to individually set each input independently For rates other than these rates the reclocker can be bypassed to allow other non SDI rates to pass through Selection of inputs to outputs are made either via the front panel push button switches via the remote panel push button switches if fitted or via SNMP see SNMP section of this manual Input 1A corresponds to the top most switch consecutively down to input 4A followed by input 1B consecutively down to input 4B at the bottom most switch When a front panel switch is pressed provided there is a valid signal corresponding to its input the switch will illuminate green showing that its input is now switched to its output If a non valid signal is present that is at the wrong rate or absent altogether the front panel switch will illuminate orange and the output will be muted A remote panel can be connected via the remote connector on the rear assembly In the 4x2 router mode the remote panel switches mirror the front panel switches with the exception of the remote panel s
5. Revision 00 IRT 6080 DVS OPERATIONAL SAFETY WARNING Operation of electronic equipment involves the use of voltages and currents that may be dangerous to human life Note that under certain conditions dangerous potentials may exist in some circuits when power controls are in the OFF position Maintenance personnel should observe all safety regulations Do not make any adjustments inside equipment with power ON unless proper precautions are observed All internal adjustments should only be made by suitably qualified personnel All operational adjustments are available externally without the need for removing covers or use of extender cards openGear INTRODUCTION Developed by Ross Video openGear is a standard where various manufacturers can design their equipment to fit a common frame allowing the end user to mix and match the various openGear cards available in the market place together in one frame This allows a single frame to be used instead of multiple different vendor s frames that each would otherwise be using their own proprietary standard A simple to use monitoring and control software called DashBoard is a free program downloadable from the openGear website www opengear tv that allows the user to remotely monitor and control an openGear type card fitted within an openGear frame that meets the openGear standard for DashBoard control A link is also supplied via the IRT Electronics website www irtelectr
6. 1 1 pin pin wiring Only 10 pin HE 14 or 15 pin D connector need be used not both RS 232 interface for IRT RC2 remote control panel 1 1 pin pin wiring Revision 00 IRT 6080 DVS OPERATION Single 8x1 Mode With the IRT 6080 DVS set up in the single 8x1 mode inputs correspond to BNC connectors marked IP1 to IP8 and outputs correspond to BNC connectors marked OUTPUT A and OUTPUT B on the rear assembly OUTPUT A and OUTPUT B are the same when the IRT 6080 DVS is configured for 8x1 mode of operation The switcher s inputs which are all reclocked can be configured for automatic rate detection which corresponds to rates at 3G SDI HD SDI and SD SDI ASI rates It is also possible to set the inputs to 3G SDI only HD SDI only and SD SDI ASI only rates Note that all inputs are set it is not possible to individually set each input independently For rates other than these rates the reclocker can be bypassed to allow other non SDI rates to pass through Selection of input to output is made either via the front edge push button switches via the IRT RC1 remote panel pushbutton switches if fitted or via DashBoard software control Input 1 corresponds to the top most switch consecutively down to input 8 at the bottom most switch When a front edge switch is pressed provided there is a valid signal corresponding to its input the switch will illuminate green showing that its input is now switched to both outputs If a non valid si
7. buttons of the IRT 6080 DVS card itself or via the DashBoard software control The push buttons illuminate green when pressed to indicate the selected input and mirror that of the IRT 6080 DVS front edge indicators and the DashBoard software control However if there is no input or the signal rate does not match the card s set rate the IRT RC1 remote panel does not give an alarm indication In order to use the IRT RC1 remote control panel the IRT 6080 DVS requires the remote control double width rear assembly IRT 6080 ZRC Two connectors are provided for connection to the rear assembly either the 10 pin blue HE 14 type of connector wired pin for pin or a female D15 connector wired pin for pin pins 1 to 10 need only be connected only one connector need be used not both unless connecting to more IRT RC1 remote control panels to allow parallel control from multiple locations where IRT RC1 remote control panels are interconnected When switching with the IRT RC1 remote control panel push button should be pressed and held for approximately half a second The IRT RC1 front panel is designed to be mounted within the IRT RP1 remote panel mount 19 1RU panel for control desk or rack applications though it will also mount in a standard 3RU Eurocard type of frame IRT Electronics Pty Ltd www irtelectronics com Page 19 of 29 Revision 00 IRT 6080 DVS IRT RC2 Q IRT RC2 D IRT A B om IC Ck IC m m Mm Ck T
8. 2 remote control panel with 2 x 8 16 pushbuttons amp tally LED s Standard programmed with DashBoard control Remote control panel with 8 pushbuttons amp tally LED s RS 232 remote control panel with 2 x 8 16 pushbuttons amp tally LED s Double width rear assembly for IRT RC1 and IRT RC2 remote control panels 1RU 19 rack mounting plate for IRT RC1 and IRT RC2 remote control panels Due to our policy of continuing development these specifications are subject to change without notice IRT Electronics Pty Ltd www irtelectronics com Page 6 of 29 Revision 00 IRT 6080 DVS CONFIGURATION The IRT 6080 is an 8 input 2 output device that may be configured via on board DIP switches as a single 8x1 switcher where both outputs are the same an 8x2 router where both outputs are independent from each other required to be used in conjunction with a remote panel or via Dashboard control a 4x2 router where outputs are independent from each other and inputs 1A 4A 1 4 are internally connected to inputs 1B 4B 5 8 DIP Switch settings DIP O DIP kaukana ulna 12345 6 7 8 12345 6 7 8 SW 10 SW11 Output Signal Rate Set 8x1 and SW10 1 A Output of 8x2 amp dual 4x1 amp 4x2 modes Auto Detect SD SDI ASI only ON OFF HD SDI only OFF O JON O 3G SDI only ON FON SW10 3 OFF 8 input mode ON 4 input mode SW10 4 OFF 8x1 mode In 8 input mode remote panel mi
9. C1 remote panel The pins are momentary wire per crosspoint WPX control lines and can also be used with an external momentary switch to ground telemetry system The 3 3Vdc power is for powering the LEDs of the remote panel 3 3Vdc Power REMOTE 1 REMOTE 3 REMOTE 5 REMOTE 7 REMOTE oh hhe api T B ol i Ky 15 pin D Connector Pin Assignments GND REMOTE 2 REMOTE 4 REMOTE 6 REMOTE 8 On the remote rear assembly a 15 pin D connector female style of connector is used for pin to pin connection to the 15 pin D connector female style of connector of the optional IRT RC1 remote panel The pins are momentary wire per crosspoint WPX control lines and can also be used with an external momentary switch to ground telemetry system The 3 3Vdc power is for powering the LEDs of the remote panel The Remote RS 232 Tx and Rx pins are not used with the IRT RC1 remote control panel and do not need to be wired though no issues will occur if they are RN Saat PIN 1 REMOTE 1 i PY wae N y 9 pin RS 232 D Connector Pin Assignments 2 O CON DMD UB W 11 12 13 14 15 REMOTE 2 REMOTE 3 REMOTE 4 REMOTE 5 REMOTE 6 REMOTE 7 REMOTE 8 3 3Vdc Power GND Not Connected Not Connected Not Connected RS 232 Tx RS 232 Rx On the remote rear assembly a 9 pin RS 232 D connector female connector is used for pin to pin connection to the 9 pin RS 232 D con
10. Priority OUT B IRT Electronics Pty Ltd www irtelectronics com Page 26 of 29 Revision 00 IRT 6080 DVS In this example the switcher has been set up as a dual independent 4x1 switcher OUT A input settings are independent to OUT B input settings likewise inputs 1 to 4 are independent to inputs 5 to 8 Rear Assembly Rate Settings OUT A amp OUT B amp Output Channel A OUT A Name Signal Status OUT A Priority OUT A CHANNEL 1A 3G Locked fMmmDisabled Output Channel B OUT B Name Signal Status OUT B Priority OUT B SD IRT Electronics Pty Ltd www irtelectronics com Page 27 of 29 Revision 00 IRT 6080 DVS In this example the switcher has been set up as a 4x2 router OUT A input settings are independent to OUT B input settings though the same inputs 1 to 4 are available to each output Inputs 5 to 8 are not used in this mode OPICO Point selection Config Rear Assembly Rate Settings Output Channel A OUT A Name Signal Status OUT A Priority OUT A CHANNEL 1 3G Locked I ZN Output Channel B OUT B Name Signal Status OUT B Priority OUT B IRT Electronics Pty Ltd www irtelectronics com Page 28 of 29 Revision 00 IRT 6080 DVS MAINTENANCE amp STORAGE Maintenance No regular maintenance is required Care however should be taken to ensure that all connectors are kept clean and free from contamination of any kind This is especially important in fibre optic equipment where cleanliness of optical c
11. assembly Only BNC signal inputs and outputs are fitted Control of the IRT 6080 DVS is only via either the front panel edge switches or via the DashBoard software control For remote monitoring via pushbutton switches two types of remote panels are available depending on the switcher function required If the IRT 6080 DVS is to be set up as an 8x2 router then the IRT RC2 remote control panel is required All other functions that require remote pushbutton control require the IRT RC1 remote control panel Both these remote control panels require the IRT 6080 ZRC double width rear assembly to replace the standard rear assembly of the IRT 6080 DVS switcher IRT RC1 is connected via either the 10 pin HE 14 style header or via the 15 pin D connector Cable wiring is 1 1 pin pin Note that the HE 14 pin connections are wired in parallel with the D15 connector pins Although both are provided only one connector need be wired to the optional IRT RC1 panel IRT RC2 is connected via the 9 pin RS 232 D connector Cable wiring is 1 1 pin pin Wire per crosspoint WPX control by an external source is also possible via the 10 pin HE 14 style header or the 15 pin D connector IRT Electronics Pty Ltd www irtelectronics com Page 13 of 29 Revision 00 HE 14 Connector Pin Assignments IRT 6080 DVS On the remote rear assembly a 10 pin HE 14 style of connector is used for pin to pin connection to the 10 pin HE 14 style of connector of the optional IRT R
12. erly packed for return observing antistatic procedures The following information should accompany the unit to be returned A fault report should be included indicating the nature of the fault The operating conditions under which the fault initially occurred Any additional information which may be of assistance in fault location and remedy A contact name and telephone and fax numbers Details of payment method for items not covered by warranty Full return address For situations when No Fault Found for repairs a minimum charge of 1 hour s labour will apply whether the equipment is within the warranty period or not Contact IRT for current hourly rate e ee ee a Please note that all freight charges are the responsibility of the customer The equipment should be returned to the agent who originally supplied the equipment or where this is not possible to IRT directly Details of IRT s direct address can be found at IRT Electronics website Web address www irtelectronics com Email sales irtelectronics com IRT Electronics Pty Ltd www irtelectronics com Page 29 of 29 Revision 00
13. erting or removing cards from these bags Installation in openGear frame See details in separate manual downloadable from the openGear website www opengear tv Signal Inputs amp Outputs The IRT 6080 DVS can be configured as a single 8x1 switcher an 8x2 router dual independent 4x1 switchers or a 4x2 router as described in the Configuration section of this handbook Inputs and Outputs are 75 Q BNC type for connection with high quality 75 Q coaxial cable Inputs are self terminating Two outputs labelled as OUTPUT A and OUTPUT B are located at the top of the rear assembly below which the inputs are labelled as being IP1 1A IP2 2A IP3 3A IP4 4A IPS 1B IP6 2B IP7 3B and IPS 4B When the IRT 6080 DVS is configured as a single 8x1 switcher or 8x2 router the designators IP1 to IP8 apply to represent the 8 inputs When the IRT 6080 DVS has been set up for the dual 4x1 mode there are effectively two separate switchers with separate inputs These are designated as being IP1A to IP4A for Output A s 4x1 switcher and IP1B to IP4B for Output B s 4x1 switcher When the IRT 6080 DVS has been set up for the 4x2 router mode inputs IP1B to IP4B or IP5 to IP8 are non functional Output A is independent from Output B but the inputs IP1A to IP4A are shared between both Output A and Output B though independently controlled Remote Rear Assembly Wiring The IRT 6080 DVS is supplied with its own standard rear
14. etect mode reclocker is bypassed on non 3G HD SD ASI rates and passes input to outputs N A Not Applicable for 3G SDI only HD SDI only and SD SDI ASI only fixed rate modes User s Choice Applies to both 4x1 switchers concurrently i OFF In Auto Detect mode the outputs are muted if a selected input is not at the SW11 4 ON 4x2 router mode Inputs 1B to 4B automatically mirror inputs 1A to 4A SW11 5 OFF Factory use only leave OFF W11 6 OFF Enable front edge and remote panel switches 5 to 8 1B to 4B S User s Choice D ka i ON Disable front edge and remote panel switches 5 to 8 1B to 4B Tally only SW11 7 Not Used SW11 8 OFF Front edge and remote panel switches switch immediately when pressed User s Choice ON Front edge and remote switches must be held for approximately 2 seconds Applies to both 4x1 before change in switcher state occurs switchers concurrently N A Not Applicable if front edge and remote panel switches have been disabled for Tally indication only IRT Electronics Pty Ltd www irtelectronics com Page 12 of 29 Revision 00 IRT 6080 DVS INSTALLATION Pre installation Handling This equipment may contain or be connected to static sensitive devices and proper static free handling precautions should be observed Where individual circuit cards are stored they should be placed in antistatic bags Proper antistatic procedures should be followed when ins
15. gether Data rate and push button enable disable settings are independently set between each output I P 1A to 4A gt O P A and I P 1A to 4A gt O P B where O P A and O P B are controlled independently from each other The top four switches of the local front edge control O P A of the router and the bottom four switches control O P B likewise for the optional IRT RC1 remote control panel IRT 6080 DVS 4x2 I P 1A 1 PAA 4 O P A I P_1B 5 O P B I P 4B 8 IRT RC1 Remote Panel DashBoard Control SW10 1 O P A Rate Set in conjunction with SW10 2 See page 7 SW10 1 OFF SW10 2 OFF User s Choice SW10 2 O P A Rate Set in conjunction with SW10 1 See page 7 O P A independent from O P B I P s 1A to 4A internally connected to P s 1B to 4B actual physical inputs 1B to 4B not used Auto Detect SW10 3 ON 4 input mode set in conjunction with SW11 4 ON SW10 4 N A Not Applicable SW10 5 OFF Factory use only leave OFF W10 6 OFF Enable front edge and remote panel switches 1A to 4A 1 to 4 S User s Choice cleo ON Disable front edge and remote panel switches 1A to 4A 1 to 4 Tally only SW10 7 Not Used SW10 8 Not Used l SW11 1 O P B Rate Set in conjunction with SW11 2 See page 7 SW11 1 OFF SW11 2 OFF User s Choice SW11 2 O P B Rate Set in conjunction with SW11 1 See page 7 Auto Detect 3G HD SD ASI rate ON In Auto D
16. gnal is present that is at the wrong rate or absent altogether the front panel switch will illuminate orange and the outputs will be muted An IRT RC1 remote panel can be connected via the 10 pin remote connector on the remote rear assembly Provision is also made to fit DB15 pin D connectors as an alternative as well In the single 8x1 mode the remote panel switches mirror the front edge switches with the exception of the remote panel switches can only illuminate green regardless of the validity or absence of an input Front edge and remote panel switches can be disabled for tally indication only when switching via DashBoard software control It is also possible to set the switches so that they have to be pressed for approximately 2 seconds before switching will actually take place This is so that accidental switching does not take place if the switch panel is brushed against or bumped 8x2 Router Mode With the IRT 6080 DVS set up in the 8x2 router mode inputs correspond to BNC connectors marked IP1 to IP8 and outputs correspond to BNC connectors marked OUTPUT A and OUTPUT B on the rear assembly OUTPUT A and OUTPUT B are independent from each other when the IRT 6080 DVS is configured for 8x2 router mode of operation The switcher s inputs which are all reclocked can be configured for automatic rate detection which corresponds to rates at 3G SDI HD SDI and SD SDI ASI rates It is also possible to set the inputs to 3G SDI only HD SDI
17. he IRT RC2 remote panel is a 2 x 8 16 button remote control panel that allows pushbutton control to the IRT 6080 DVS when set to either the 8x2 router mode It can still be used for the other modes but is not recommended When the IRT 6080 DVS is set for 8x2 router mode one bank of switches controls the A output whilst the second bank of switches control the B output The push buttons illuminate green when pressed to indicate the selected input and mirror that the DashBoard software control Unlike the IRT RC1 remote control panel if there is no input or the signal rate does not match the card s set rate the IRT RC2 remote panel does give an alarm indication by illuminating yellow when the corresponding push button is pressed In order to use the IRT RC2 remote control panel the IRT 6080 DVS requires the remote control double width rear assembly IRT 6080 ZRC One female D9 connector is provided for connection to the female D9 connector of the rear assembly Connectors are wired pin for pin Control is via RS 232 signals In order to operate multiple IRT RC2 remote control panels to allow parallel control from multiple locations the control lines need to be paralleled into the same connector there is no second port to allow expansion The IRT RC2 front panel is designed to be mounted within the IRT RP1 remote panel mount 19 1RU panel for control desk or rack applications though it will also mount in a standard 3RU Eurocard t
18. itches if fitted or via SNMP see SNMP section of this manual Input 1A corresponds to the top most switch consecutively down to input 4A followed by input 1B consecutively down to input 4B at the bottom most switch When a front panel switch is pressed provided there is a valid signal corresponding to its input the switch will illuminate green showing that its input is now switched to its output If a non valid signal is present that is at the wrong rate or absent altogether the front panel switch will illuminate orange and the output will be muted A remote panel can be connected via the remote connector on the rear assembly In the dual 4x1 mode the remote panel switches mirror the front panel switches with the exception of the remote panel switches can only illuminate green regardless of the validity or absence of an input Front panel switches per 4x1 switcher can be disabled for tally indication only when switching via a remote panel or via SNMP It is also possible to set the switches so that they have to be pressed for approximately 2 seconds before switching will actually take place This is so that accidental switching does not take place if the switch panel is brushed against or bumped 4x2 Router Mode With the IRT 6080 DVS set up in the 4x2 router mode inputs correspond to BNC connectors marked IP1A to IP4A and outputs correspond to BNC connectors marked OUTPUT A and OUTPUT B on the rear assembly Inputs IP1B to IP4B are not used
19. l switching ensure Priority OUT B is Disabled Mute Output on Loss of Lock Disabled Page 24 of 29 Revision 00 IRT 6080 DVS Output Cross Point Selection TAB Under this TAB remote user control of the switcher takes place With the computer mouse clicking on the relevant channel input will switch this input to the relevant output As well as the user control operation information is shown as to the set output rate and alarm conditions such as whether the card has been plugged into the wrong type of rear assembly and the signal status of the output Note that Priority Control is disabled and is a non documented feature In this example the switcher has been set up as an 8x1 switcher Clicking on an input relating to OUT A will also switch the corresponding input to OUT B Rear Assembly Rate Settings OUT A Ai t Esme Auto Detect l Output Channel A OUT A Name Signal Status OUT A Priority OUT A Output Channel B OUT B Name Signal Status OUT B Priority OUT B IRT Electronics Pty Ltd www irtelectronics com Page 25 of 29 Revision 00 IRT 6080 DVS In this example the switcher has been set up as an 8x2 router OUT A input settings are independent to OUT B input settings though the same inputs 1 to 8 are available to each output MOliputlcross Point Selection Config Rear Assembly Rate Settings Output Channel A OUT A Name Signal Status OUT A Priority OUT A CHANNEL 1 Output Channel B OUT B Name Signal Status OUT B
20. nector female connector of the optional IRT RC2 remote panel IRT Electronics Pty Ltd www irtelectronics com Page 14 of 29 Revision 00 IRT 6080 DVS Front Edge LED and Switches Locations Front Edge Mount Switches Front Edge LED Indicators In this situation I P 1 selected Green Valid input rate Red No input or invalid rate SAQG 0809 Lul SW_ boot switch Default Reset Switch User set names and switch position are stored within memory so that in the event of a loss of power this information is restored on resumption of power If the default Reset Switch is pressed whilst powering or inserting the card the IRT 6080 DVS will default to factory preset names and input position IRT Electronics Pty Ltd www irtelectronics com Page 15 of 29 Revision 00 Rear Assembly Layouts yo amp os 7 pi AA bij AA i SAN N yf M N HE F3 FJ oo f SS k a ko o 1A IP 5 1B amp IP 3 3A IP 7 i 5 2 4A Faa at Standard Rear Assembly IRT 6080 ZVS e A OUTPUT B ES as iM N i N Q W A Hi t 1 a SS ko o 1A IP 5 1B IP 6 2B IP 3 3A IP 7 7 i C7 IP 8 4B Remote Control Double Width Rear Assembly IRT 6080 ZRC IRT Electronics Pty Ltd www irtelectronics com Page 16 of 29 IRT 6080 DVS Wire per crosspoint WPX interfaces for IRT RC1 remote control panel
21. nics Pty Ltd www irtelectronics com Page 22 of 29 Revision 00 Config TAB IRT 6080 DVS Under the Configuration TAB parameters such as Product Alias name and channel names Input 1 to Input 8 can be user set Click computer mouse into the field to change and type new name Outputs Cross Point Selection Product Alias Input 1 Name Input 2 Name Input 3 Name Input 4 Name Input 5 Name Input 6 Name Input 7 Name Input 6 Name Page 23 of 29 Multi Mode Switcher CHANNEL 1 CHANNEL 2 CHANNEL 3 CHANNEL 4 CHANNEL 5 CHANNEL 6 CHANNEL 7 CHANNEL 8 IRT Electronics Pty Ltd www irtelectronics com Revision 00 Dipswitch Settings TAB IRT 6080 DVS Switcher configuration is set by on board DIP switches This TAB shows how the switcher has been configured In this case the switcher has been set up as an 8x1 switcher with local and remote panel switches enabled and 2 second switch delay disabled Note that Priority Control is disabled and is a non documented feature Frame 50084695003 Slot 18 Multi Mode Switcher x Slot 18 Multi Mode Switcher Card state Ok ONLINE Status MDipswncnsemnge Connection Product Switcher Mode Priority Control Panel Switches for OUT A Panel Switches for OUT B Auto Detect Loss of Lock Setting Two Second Delay for Switches 8x1 Switcher OUT A amp OUT B Disabled Enabled Note For manual switching ensure Priority OUT A is Disabled Enabled Note For manua
22. ntrinsic jitter Power Requirements Voltage Power consumption Connectors 3G HD SD SDI ASI Control with remote option Other Temperature range Mechanical Dimensions openGear standard Supplied accessories Optional accessories IRT 6080 DVS IRT RC1 IRT RC2 IRT 6080 ZRC IRT RP1 Ordering IRT 6080 DVS 8 3G SDI HD SDI SD SDI or ASI gt 100 m at 2 97 Gb s 3G SDI with Belden 1694A gt 100 m at 1 485 Gb s HD SDI with Belden 1694A gt 250 m at 270 Mb s SD SDI ASI with Belden 8281 75 Q 2 x 800 mV 10 into 75 Q Momentary wire per crosspoint WPX grounding contacts Front edge push button switches or optional IRT RC1 remote control panel openGear DashBoard software RS 232 9600bps 8 data bits No parity 1 Stop bit No flow control optional IRT RC2 remote control panel gt 15 dB 5 MHz to 1 5 GHz gt 10 dB 1 5 GHz to 2 97 GHz 0 V 0 5 V lt 135 ps at 2 97 Gb s and 1 485 Gb s 0 4 ns and lt 1 5 ns at 270 Mb s lt 0 3 Ul at 2 97 Gb s reclocked lt 0 2 Ul at 1 485 Gb s reclocked lt 0 1 Ul at 270 Mb s reclocked 12 Vdc lt 5VA BNC Plug in 10 pin HE14 dual IDC DB9 or DB15 0 50 C ambient Suitable for mounting in an openGear 2RU rack chassis 33 6 mm x 2U x 325 mm 67 3 mm x 2U x 325 mm with remote option rear assembly Rear connector assembly IRT RC1 remote control panel with 8 pushbuttons amp tally LED s IRT RC2 RS 23
23. onics com under the openGear navigation section IRT Electronics openGear cards are designed to meet the openGear standard for mounting within the openGear OG3 FR frame and its earlier version DFR 8300 frame and is fully compliant with DashBoard control The openGear frame manual DashBoard control software and information regarding the frame s power supplies controller card and frame accessories are available for download at the openGear website The term openGear is a registered trade mark of Ross Video Limited DashBoard software Control is a trade mark of Ross Video Limited IRT Electronics Pty Ltd www irtelectronics com Page 4 of 29 Revision 00 IRT 6080 DVS GENERAL DESCRIPTION BLOCK DIAGRAM IRT 6080 DVS SIGNAL PATH 3G HD SD SDI ASI I P 2 2A EQUALISER OUTPUT O EC UALISER 0 0 P I P 3 3A QUAL 8x1 DE 0 O P 1 iiaii I P 4 4A 4 EQUALISER Dual 4x1 HD SDI 3G HD SD SD SDI I P 5 1B EQUALISER ASI ASI EQUALISER _ SWITCHER OUTPUT gt I P 6 2B EQUALISER ance 90 2 I P 7 3B EQUALISER _ I P 8 48 EQUALISER LOCAL CONTROL I DASHBOARD The IRT 6080 DVS digital video switcher is part of a family of smart switchers in openGear format that may be configured by the user to cover a wide range of switching and monitoring functions On board configuration is possible to allow the IRT 6080 DVS to be u
24. only and SD SDI ASI only rates Note that all inputs are set it is not possible to individually set each input independently For rates other than these rates the reclocker can be bypassed to allow other non SDI rates to pass through For push button router control an IRT RC2 remote panel is connected to the DB9 RS 232 D connector port on the remote rear assembly One row of 8 push button switches controls and monitors OUTPUT A whilst the second row of 8 push button switches controls and monitors OUTPUT B Connection is made via a though it is still possible to use the IRT 6080 DVS as an 8x2 router without the use of the remote panel when controlling via SNMP see SNMP section of this manual Output A is made via selection of input via the front panel push button switches Output B is made via selection of input via the remote panel push button switches Input 1 corresponds to the top most switch consecutively down to input 8 at the bottom most switch When a front panel switch is pressed provided there is a valid signal corresponding to its input the switch will illuminate green showing that its input is now switched to output A If a non valid signal is present that is at the wrong rate or absent altogether the front panel switch will illuminate orange and output A will be muted With a remote panel connected via the remote connector on the rear assembly in the 8x2 router mode the remote panel switches independently from the front panel switche
25. onnections is critical to performance Storage If the equipment is not to be used for an extended period it is recommended the whole unit be placed in a sealed plastic bag to prevent dust contamination In areas of high humidity a suitably sized bag of silica gel should be included to deter corrosion Where individual circuit cards are stored they should be placed in antistatic bags Proper antistatic procedures should be followed when inserting or removing cards from these bags WARRANTY amp SERVICE Equipment is covered by a limited warranty period of three years from date of first delivery unless contrary conditions apply under a particular contract of supply For situations when No Fault Found for repairs a minimum charge of 1 hour s labour at IRT s current labour charge rate will apply whether the equipment is within the warranty period or not Equipment warranty is limited to faults attributable to defects in original design or manufacture Warranty on components shall be extended by IRT only to the extent obtainable from the component supplier Equipment return Before arranging service ensure that the fault is in the unit to be serviced and not in associated equipment If possible confirm this by substitution Before returning equipment contact should be made with IRT or your local agent to determine whether the equipment can be serviced in the field or should be returned for repair The equipment should be prop
26. rrors local front edge switches O P A O P B ON 8x2 router mode O P A independent from O P B N A Not Applicable to 4 input mode i e if SW10 3 ON SW10 5 OFF Factory use only leave OFF SW10 6 OFF Enable front edge and remote panel switches for 8x1 mode and O P A switches of 8x2 and dual 4x1 amp 4x2 modes ON Disable front edge and remote panel switches Tally indication only Control only possible via Dashboard control for 8x1 mode and O P A switches of 8x2 and dual 4x1 amp 4x2 modes SW10 7 Not Used SW10 8 Not Used B Output Signal Rate Set SW11 1 SW11 2 8x2 dual 4x1 amp 4x2 modes only Auto Detect SD SDI ASI only ON OFF HD SDI only OFF LON 3G SDI only ON JON O SW11 3 OFF Reclocker mode In Auto Detect mode the outputs are muted if a selected input is not at the 3G HD SD ASI rate ON Bypass Reclocker In Auto Detect mode reclocker is bypassed on non 3G HD SD ASI rates and passes input to outputs SW11 4 OFF Dual 4x1 mode In 4 input mode switcher behaves as two independent 4x1 switchers A Inputs gt O P A B Inputs gt O P B ON 4x2 router mode In 4 input mode B inputs mirror A inputs A Inputs gt O P A amp independently to O P B NOTE Actual physical inputs 1B 5 2B 6 3B 7 amp 4B 8 are disabled N A Not Applicable to 8 input mode i e if SW10 3 OFF IRT Electronics Pty Ltd www i
27. rtelectronics com Page 7 of 29 Revision 00 IRT 6080 DVS SW11 5 Factory use only leave OFF SW11 6 OFF Enable front edge and remote panel switches for O P B switches of 8x2 dual 4x1 amp 4x2 modes only ON Disable front edge and remote panel switches Tally indication only for O P B switches of 8x2 dual 4x1 amp 4x2 modes only N A Not Applicable for 8x1 mode of operation SW11 7 Not Used SW11 8 OFF Front edge and remote panel switches switch immediately when pressed NOTE 1 ON Front edge and remote panel switches must be held for approximately 2 seconds before change in switcher state occurs N A Not Applicable for front and remote panel switches when these have been disabled for Tally indication only Auto Detect mode will allow 3G SDI HD SDI and SD SDI or ASI signals to pass to the output even if inputs are of mixed types DIP switch SW11 3 gives the option of either muting both outputs if a selected input is at a rate other than the 3G HD SD SDI rates or the internal reclocker is bypassed and the signal will still pass through though the output level is still 300mV regardless of the other rate s standard 3G SDI only HD SDI only and SD SDI only settings will only pass an input if it is at the correct set rate else the output will be muted if a chosen input does not match the set rate Leave SW10 5 and SW11 5 OFF Reserved for Factory use only In order to prevent accidental swi
28. s ON Disable O P A front edge and O P A remote panel switches Tally indication only SW10 7 Not Used SW10 8 Not Used SW11 1 O P B Rate Set in conjunction with SW11 2 See page 7 SW11 1 OFF SW11 2 OFF User s Choice SW11 2 O P B Rate Set in conjunction with SW11 1 See page 7 Avto Detect SW11 3 OFF Reclocker mode In Auto Detect mode the outputs are muted if a selected input is not at the 3G HD SD ASI rate User s Choice ON Bypass reclocker In Auto Detect mode reclocker is bypassed on non 3G HD SD ASI rates and passes input to outputs N A Not Applicable for 3G SDI only HD SDI only and SD SDI ASI only fixed rate modes SW11 4 N A Not Applicable SW11 5 OFF Factory use only leave OFF SW11 6 OFF Enable O P B remote panel switches ON Disable O P B remote panel switches Tally indication only SW11 7 Not Used SW11 8 OFF Front edge and remote panel switches switch immediately when pressed ON Front edge and remote switches must be held for approximately 2 seconds User s Choice before change in switcher state occurs N A Not Applicable if front edge and remote panel switches have been disabled for Tally indication only IRT Electronics Pty Ltd www irtelectronics com Page 10 of 29 Revision 00 IRT 6080 DVS Dual 4x1 Switcher Quick Set up Guide In the dual 4x1 mode each half of the IRT 6080 DVS behaves as an independent 4x1 switcher Data rate and p
29. s however the remote panel switches can only illuminate green regardless of the validity or absence of an input Front panel switches can be disabled for tally indication only when switching via a remote panel or via SNMP It is also possible to set the switches so that they have to be pressed for approximately 2 seconds before switching will actually take place This is so that accidental switching does not take place if the switch panel is brushed against or bumped IRT Electronics Pty Ltd www irtelectronics com Page 17 of 29 Revision 00 IRT 6080 DVS Dual 4x1 Mode With the IRT 6080 DVS set up in the dual 4x1 mode two separate 4x1 switchers operate independently from each other OUTPUT A s inputs correspond to BNC connectors marked IP1A to IP4A and OUTPUT B s inputs correspond to BNC connectors marked IP1B to IP4B on the rear assembly Each 4x1 switcher s inputs which are all reclocked can be configured for automatic rate detection which corresponds to rates at 3G SDI HD SDI and SD SDI ASI rates It is also possible to set the inputs to 3G SDI only HD SDI only and SD SDI ASI only rates Note that all inputs per 4x1 switcher are set it is not possible to individually set each input independently For rates other than these rates the reclocker can be bypassed to allow other non SDI rates to pass through Selection of input to output is made either via the front panel push button switches via the remote panel push button sw
30. sed as an 8x1 switcher with 2 common outputs a dual independent 4x1 switcher an 8x2 or 4x2 router Push button switches along the front edge provide local control although control is usually intended via a software interface such as DashBoard Optionally remote control is via a momentary wire per crosspoint WPX control connector allowing interface to a remote control panel or a telemetry system or alternatively an RS232 remote control is also available providing extended control Front edge switches can be disabled for tally indication only so as to prevent accidental switching when intending only to use one of the remote control options The IRT 6080 DVS is designed to fit the openGear standard 2RU frames which allow a mixture of cards from various manufacturers to be mounted within the same frame The DashBoard control software is available as a free download Standard features 3G SDI HD SDI SD SDI or ASI capable 8x1 or dual 4x1 switching operation 8x2 or 4x2 router setup Automatic muting on loss of inputs Front edge local control with remote control option DashBoard software monitoring and control IRT Electronics Pty Ltd www irtelectronics com Page 5 of 29 Revision 00 TECHNICAL SPECIFICATIONS Signal inputs Number Type Automatic cable compensation Impedance Signal outputs Type Control Type 1 Type 2 Type 3 Performance Return loss DC offset Output rise and fall time I
31. tching via the front edge or remote panel switches switches must be held in the pressed state for approximately 2 seconds before switching will occur IRT Electronics Pty Ltd www irtelectronics com Page 8 of 29 Revision 00 IRT 6080 DVS 8x1 Switcher Quick Set up Guide Outputs A and B are the same What is switched to O P A will also switch to O P B IRT 6080 DVS 8x1 O P A O P A O PB O P B IRT RC1 Remote Panel DashBoard Control SW10 1 Rate Set in conjunction with SW10 2 See page r SW10 1 OFF SW10 2 OFF User s Choice A SW10 2 Rate Set in conjunction with SW10 1 See page 7 uto Detect SW10 3 OFF 8 input mode SW10 4 OFF 8x1 mode O P A O P B SW10 5 OFF Factory use only leave OFF User s Choice SW10 6 OFF Enable front edge and remote panel switches ON Disable front edge and remote panel switches Tally indication only SW10 7 Not Used SW10 8 Not Used SW11 1 N A Not Applicable SW11 2 N A Not Applicable SW11 3 OFF Reclocker mode In Auto Detect mode the outputs are muted if a selected input is not at the 3G HD SD ASI rate User s Choice ON Bypass reclocker In Auto Detect mode reclocker is bypassed on non 3G HD SD ASI rates and passes input to outputs N A Not Applicable for 3G SDI only HD SDI only and SD SDI ASI only fixed rate modes SW11 4 N A Not Applicable SW11 5 N A Not Applicable SW11 6 N A Not Applicable
32. ush button enable disable settings are independent for each 4x1 switcher Inputs 1 to 4 are designated as inputs 1A to 4A and inputs 5 to 8 are designated as inputs 1B to 4B I P 1A to 4A gt O P A and I P 1B to 4B gt O P B The top four switches of the local front edge control one 4x1 switcher O P A and the bottom four switches control the other 4x1 switcher O P B likewise for the optional IRT RC1 remote control panel IRT 6080 DVS O P A O P B O P A independent from O P B I P 1A to 4A independent from I P 1B to 4B IRT RC1 Remote Panel DashBoard Control SW10 1 O P A Rate Set in conjunction with SW10 2 See page 7 sw10 1 OFF SW10 2 OFF User s Choice SW10 2 O P A Rate Set in conjunction with SW10 1 See page 7 Auto Detect SW10 3 ON 4 input mode set in conjunction with SW11 4 OFF SW10 4 N A Not Applicable SW10 5 OFF Factory use only leave OFF W10 6 OFF Enable front edge and remote panel switches 1A to 4A 1 to 4 S User s Choice ON Disable front edge and remote panel switches 1A to 4A 1 to 4 Tally only SW10 7 Not Used SW10 8 Not Used SW11 1 O P B Rate Set in conjunction with SW11 2 See page 7 SW11 1 OFF SW11 2 OFF User s Choice SW11 2 O P B Rate Set in conjunction with SW11 1 See page 7 Auto Detect 3G HD SD ASI rate ON In Auto Detect mode reclocker is bypassed on non 3G HD SD ASI rates and passes input to o
33. utputs N A Not Applicable for 3G SDI only HD SDI only and SD SDI ASI only fixed rate modes User s Choice Applies to both 4x1 switchers concurrently OFF In Auto Detect mode the outputs are muted if a selected input is not at the SW11 4 OFF Switcher behaves as two independent 4x1 switchers SW11 5 OFF Factory use only leave OFF W11 6 OFF Enable front edge and remote panel switches 1B to 4B 5 to 8 S User s Choice ON Disable front edge and remote panel switches 1B to 4B 5 to 8 Tally only SW11 7 Not Used f SW11 8 OFF Front edge and remote panel switches switch immediately when pressed User s Choice i i epics bathad ON Front edge and remote switches must be held for approximately 2 seconds switchers concurrently before change in switcher state occurs Not Applicable if front edge and remote panel switches have been disabled for Tally indication only IRT Electronics Pty Ltd www irtelectronics com Page 11 of 29 Revision 00 IRT 6080 DVS 4x2 Router Quick Set up Guide In the 4x2 router mode outputs A and B are independent from each other and inputs 1A to 4A 1 to 4 are internally connected to inputs 1B to 4B 5 to 8 respectively The actual physical BNC connectors of inputs 1B to 4B 5 to 8 are non functional In all respects the 4x2 router mode behaves in the same way as the dual 4x1 switchers mode except where the inputs are automatically internally commoned to
34. witches can only illuminate green regardless of the validity or absence of an input Front panel switches can be disabled for tally indication only when switching via a remote panel or via SNMP It is also possible to set the switches so that they have to be pressed for approximately 2 seconds before switching will actually take place This is so that accidental switching does not take place if the switch panel is brushed against or bumped IRT Electronics Pty Ltd www irtelectronics com Page 18 of 29 Revision 00 IRT 6080 DVS Remote Control Remote control of the IRT 6080 DVS is possible via three ways and is partially dependent upon the mode of operation that the unit is set up for 1 DashBoard Software Control all modes see separate section 2 IRT RC1 remote control panel with 8 pushbuttons amp tally LED s for 8x1 dual 4x1 or 4x2 modes 3 IRT RC2 RS 232 remote control panel with 2 x 8 16 pushbuttons amp tally LED s for 8x2 mode IRT RC1 Je RE Pi Galo wwe a i P amta _ gt N N gt w oo oa o I Z The IRT RC1 remote panel is an 8 button remote control panel that allows pushbutton control to the IRT 6080 DVS when set to either the 8x1 dual 4x1 or 4x2 router modes It can still be used for the 8x2 router mode however the IRT RC1 control panel will then only control one side of the 8x2 router the other half being controlled either by the front edge push
35. ype of frame IRT RP1 The IRT RP1 is a LRU 19 rack mount panel allowing up to three IRT remote panels to be mounted within a control desk or 19 rack g SS amp B 9 mmm co Y E IRT RP1 fitted with IRT RC1 and IRT RC2 remote control panels IRT Electronics Pty Ltd www irtelectronics com Page 20 of 29 Revision 00 IRT 6080 DVS The DashBoard Control and Monitoring System is a free application designed for remote control and monitoring of the openGear platform This is a free application downloadable from the openGear website www opengear tv As such configuration of the DashBoard program will not be described here The DashBoard manual is also downloadable from the openGear website Basic Tree View 9h Basic Tree View x On the left the basic tree view shows the frame With the tree structure gliacr expanded a list of cards within the frame is shown In this example slot position 18 is highlighted All sections and tabs to the right of the basic tree view EE Frame 50084695003 now relate to the card in slot position 18 in this case the IRT 6080 DVS Multi AM Slot 0 MFC 8320 N Mode Switcher The name of the switcher in this case Multi Mode Switcher can bs Slot 6 Multi Mode Switcher be set under the Configuration TAB setting Slot 10 Multi Mode Switcher A Slot 12 Multi Mode Switcher A Slot 14 Multi Mode Switcher