Contents
1. Dip switch 6 OFF Dip Switch 5 OFF Dip Switch 4 ON 40 sec Dip switch 6 ON Dip Switch 5 OFF Dip Switch 4 ON 60 sec Dip switch 6 OFF Dip Switch 5 ON Dip Switch 4 ON 120 sec Dip switch 6 ON Dip Switch 5 ON Dip Switch 4 ON 300 sec Note Auto close mode activates when the gates move to the end position or stopped manually If the transmitter push button or the key selector is activated before the auto close counting the gate will close immediately 2 1 4 Photocells Adjustment Dip 7 Photo ON When encountering any obstacles the gates will stop during opening phase stop and reverse during closing phase OFF The gate will keep moving when encountering any obstacles during closing and opening phases 2 1 5 Flashing Light Adjustment Dip 8 Light ON The flashing light blinks for 3 seconds before the gate moves and blinks simultaneously during the movement OFF The flashing light blinks and the gate moves simultaneously 2 2 SW2 Dip Switch Setting 2 2 1 Electric Latch Adjustment Dip 5 Latch ON The electric latch functions when dip switch is set to ON OFF The electric latch does not function when dip switch is set to OFF 2 2 2 Slowdown Speed Adjustment of The Gear Motors Dip 6 Slow ON The speed is 70 output of the full speed OFF The speed is 5096 output of the full speed 2 2 3 Operation Speed Adjustment of The Gear Motors Dip 7 Fast ON The s
2. O O O O 2 Setting Before powering on the control unit the following dip switch setting must be decided by gate weight and installation environment first See Figure 2 O 9 LI AAA IAS 1 5 5 E sims NC No Connection 2333 12345678 12345678 li LE O 00100006 O 1 NC 5 Latch 1 S F Set 5Auto2 2 NC 6 Slow 2 Over2 6 Auto1 7 Fast 3 0ver1 7 Photo 4 NC 8 Ds Set 4 Auto3 8 Light 2 1 SW1 Dip Switch Setting 2 1 1 Slowdown Adjustment Dip 1 S F Set ON The gear motors do not slow down before the gates completely close or open OFF The gear motors slow down before the gates completely close or open 2 1 2 Over current Adjustment Dip 2 Over2 amp Dip 3 Over1 OVER1 Dip Switch 3 OFF OVER2 Dip Switch 2 OFF Current Amp 2A Dip Switch 3 ON Dip Switch 2 OFF 3A Dip Switch 3 OFF Dip Switch 3 ON Dip Switch 2 ON Dip Switch 2 ON 4A 5A 4 CONTROL BOX Auto close 1 Dip switch 6 OFF Auto close 2 Dip Switch 5 OFF Auto close 3 Dip Switch 4 OFF 2 1 3 Gate Auto close Adjustment Dip 4 Auto 3 Dip 5 Auto 2 amp Dip 6 Auto 1 Effect No auto close Dip switch 6 ON Dip Switch 5 OFF Dip Switch 4 OFF 3 sec Dip switch 6 OFF Dip Switch 5 ON Dip Switch 4 OFF 10 sec Dip switch 6 ON Dip Switch 5 ON Dip Switch 4 OFF 20 sec
3. PC200 Control Box 24V DC GEAR MOTOR FOR RESIDENTIAL USER MANUAL Index 1 PC200 Control Box 2 Setting 2 1 5 1 Dip Switch Setting 2 1 4 Slowdown Adjustment Dip 1 S F Set 2 1 2 Over current Adjustment Dip 2 Over2 amp Dip 3 Over1 2 1 3 Gate Auto close Adjustment Dip 4 Auto 3 Dip 5 Auto 2 amp Dip 6 Auto 1 2 1 4 Photocells Adjustment Dip 7 Photo 2 1 5 Flashing Light Adjustment Dip 8 Light 22 SW2 Dip Switch Setting 2 2 1 Electric Latch Adjustment Dip 5 Latch 2 2 2 Slowdown Speed Adjustment of The Gear Motors Dip 6 Slow 2 2 3 Operation Speed Adjustment of The Gear Motors Dip 7 Fast 2 2 4 Single and Dual Gate Operation Adjustment Dip 8 Ds Set 2 3 LED Indication 24 Transmitter Memorizing and Erasing Process 2 5 System Learning Process 2 6 Gate Operation 27 Gate moving Logic 2 8 Advanced Operation of the Transmitter 3 Trouble Shooting 4 Technical Characteristics 4 1 PC200 Control Box 5 Annexes 5 1 Declaration of Conformity 0 SIIS SI SI 0 o O1r O1 O1 O1 O1 O1 O1 O1 O1 2 JIN CONTROL BOX EN 1 PC200 Control Box 1 Decide the installation position of PC200 control box first it is suggested to be installed near the gate and should be protected from possible damage Be aware of the motor cable length before deciding the installation position 2 Remove the cover by unscrewing the four screws on the cover See Figure 1 1 3 Use a screwdrive
4. Situation 3 CSk Transmitter button C for single leaf operation DkD Transmitter button D for double leaves operation See the following description 3 Trouble Shooting Situation 4 DSk Transmitter button D for single leaf operation DkC Transmitter button C for double leaves operation Overheated Back up Batteries Check the wiring connection of the batteries The gate doesn t move when pressing the button of the transmitter 1 Check if LED3 or 4 is ON 2 Check if the voltage of the batteries is below 22V 3 Check if LED1 is ON 4 Make sure all the wiring connections are firmly connected to the terminals on the PCB 5 Make sure the fuse is workable The gate only moves a little distance when pressing the button of the transmitter Make sure the wiring connection of the hall sensor is firm The transmitting distance is too short The gear motors run very slowly Make sure the connecting terminals of the Antenna is firm Check the dip switch setting of the speed adjustment The Flashing light does not work Check if the wiring connection of the flashing light is correct The leaves shall be closed instead of opening Change the polarity connection of the positive with the negative of the gear motors The leaves suddenly stop during moving 1 Check if the RESET socket is activate
5. an be memorized with 200pcs of transmitters 8 CONTROL BOX 2 5 System Learning Process Step1 Connect the master motor wires to M1 terminals and the slave motor wires to M2 terminals correctly If only one gate is installed the motor wires have to be connected to M1 terminals Step2 Press and hold the S2 button on the PCB for 5 seconds After LED1 blinks once per second press the button on the transmitter to choose dual gate A button or single gate B button system learning In system learning mode the gates will proceed with the following procedures Dual Gate Mode Slave Gate closes Master Gate closes Master Gate opens Slave Gate opens Slave Gate closes Master Gate closes B Single Gate Mode Master Gate closes Master Gate opens Master Gate closes The completion of system learning A For Dual Gate installation The system learning is completed when LED1 quickly blinks twice per second B For Single Gate installation The system learning is completed when LED1 quickly blinks once per second Notes A System learning fails and needs to be learned again when an unpredictable interruption occurs B Once the system learning is completed there is no need to proceed with the learning process again when there isa power failure C The slave gate opens 3 seconds after the master gate opens and the master gate closes 3 seconds after the slave gate closes 2 6 Gate Operation Press the button A on the transmitte
6. d 2 Make sure the wiring connection of the gear motors is firm 3 Make sure the hall sensor wiring connection is firm 4 The GND terminal of the photocells on the PCB must be short circuited if no photocells installed 5 Make sure the fuse is workable The leaves does not move or only move toward one direction 1 Check if the RESET socket is activated 2 Make sure the wiring connection of the gear motors is firm 3 Make sure the hall sensor wiring connection is firm 4 The GND terminal of the photocells on the PCB must be short circuited if no photocells installed The master gate closes to the end first and the slave gate stops the flashing light blinks fast for five seconds Cut off the AC input power and the output of the batteries Release the master gate and slave gate manually then open the master to the end and close the slave gate to the end by hand then power the whole unit by connecting the AC and battery terminals The gear motors does not run and the relay is noisy when operating the gate opening and closing Check if the fuse is burned ga CONTROL BOX 4 Technical Characteristics 4 1 PC200 Control Box Application For PW220 PW230 poweFor PW320 PW330 power supply Main power supply 230Vac 110Vac 50Hz 60Hz Back up battery 2pcs of batteries for emergency operation 1 2A each Transformer 6A 24V Receiver board 433 92MHz 200 transmitters memory Installation Wall mounted ver
7. peed is 100 output of the full speed OFF The speed is 70 output of the full speed 2 2 4 Single and Dual Gate Operation Adjustment Dip 8 Ds Set ON Dual Gates operation in system learning and normal operation OFF Single Gate operation in system learning and normal operation CONTROL BOX 2 3 LED Indication LED1 System Learning LED1 blinks once when single gate learning is completed LED1 blinks twice when dual gate learning is completed LED2 RF If the switch of the transmitter key selector or the push button is activated LED2 will be on LED3 Photocells 1 LED3 will be on when the first pair of the photocells are activated LED4 Photocells 2 LED4 will be on when the second pair of the photocells are activated LED5 RF Indicator LED5 will be on when RF signal is received Transformer u 1234 5678 12545678 Sinn OF ka 24V o eec 5 2 4 Transmitter Memorizing and Erasing Process A Transmitter Memorizing Press and hold the S3 button on the PCB for 1 second and then the blue LED indicator on the RF board will be ON Press A button for dual gate installation press B button for single gate installation on the transmitter within 5 seconds The transmitter learning is completed when the blue indicator is OFF B Transmitter Memory Erasing Press and hold the S3 button on the PCB for three seconds C One radio receiver c
8. r for dual gate operation Press the button B on the transmitter for single gate operation in either single gate or dual gate installation 2 7 Gate moving Logic A In gate opening phase The gates stop if the transmitter push button key selector is activated and close when the transmitter push button key selector is reactivated B In gate closing phase The gates stop if the transmitter push button key selector is activated and open when the transmitter push button key selector is reactivated C In gate opening or gate closing phase For safety purpose the gates stop if encountering obstacles 2 8 Advanced Operation of the Transmitter You could decide the buttons of the transmitter to operate single or double leave by adjusting the position of JP3 jumpers For two channel transmitter there are two adjustments Situation 1 ASk Transmitter button A for single leaf operation DkB Transmitter button B for double leaves operation Situation 2 BSk Transmitter button B for single leaf operation DkA Transmitter button A for double leaves operation CONTROL BOX For four channel transmitter there are four normal adjustments Situation 1 ASk Transmitter button A for single leaf operation DkB Transmitter button B for double leaves operation Situation 2 BSk Transmitter button B for single leaf operation DkA Transmitter button A for double leaves operation
9. r to puncture the holes beneath the bottom of the control box See Figure 1 2 4 Secure it on the wall See Figure 1 3 Figure 1 1 Figure 1 2 Figure 1 3 5 Wiring Connection Prepare all the wires of the accessories beforehand and connect the wires to the gear motors and accessories on the PCB as shown in Figure 1 4 All of the wiring connections of the accessories are not requested to distinguish the positive and the negative polarity 1 PF 1 Flashing light Connect the two wires from the flashing light to the terminal LIT and LIT on the PCB 2 PEL 1 Electric Latch Connect the two wires from the electric latch to the terminal LAT and LAT on the PCB 3 PW150 PW200 Gear Motors Refer to Figure 1 5 and connect the wires separately to the terminals on the PCB M1 Connect the motor wire White to the terminals M1 and Yellow to the M1 Connect the hall sensor wires red green and black to the terminals 5V 51 and GND M2 Connect the motor wire White to the terminals M2 and Yellow to the M2 Connect the hall sensor wires red green and black to the terminals 5V S2 and GND Notes For gates opened outward M1 Connect the motor wire Yellow to the terminals M1 and White to the terminals M1 M2 Connect the motor wire Yellow to the terminals M2 and White to the terminals M2 4 PH 1 Photocells See Figure 1 4 and Figure 1 5 A In the installa
10. tically Operating Temperature 20 C 50 C Dimension 275mm 195mm 102mm P 1095 Budapest Mester u 34 1141 Budapest Fogarasi t 77 Tel 218 5542 215 9771 215 7550 220 7940 220 7814 220 7959 216 7017 216 7018 Fax 218 5542 220 8881 364 3428 Fax 220 7940 Mobil 30 940 1970 20 949 2688 Mobil 30 531 5454 30 939 9989 E mail delton delton hu Web www delton hu www kaputnyitunk hu CONTROL BOX EI
11. tion of one set Connect the wires referred to 7 and 9 And remove the electric jumper JP1 B In the installation of two sets connect the wires referred to 7 8 9 and 10 And remove both the electric jumper JP2 and JP1 Figure 1 4 83 2 i gt 5 PKS 1 Key Selector For single gate installation Refer to Figure 1 6 and connect the two wires from the key selector to the terminal SKEY and GND on the PCB For dual gate installation Refer to Figure 1 5 and connect the two wires from 5 the key selector to the terminal DKEY and GND on the PCB 6 PPB 1 Push Button For single gate installation Refer to Figure 1 6 and connect the two wires from the push button to the terminal SKEY and GND on the PCB For dual gate installation Refer to Figure 1 5 and connect the two wires from the push button to the terminal DKEY and GND on the PCB For Dual leaf operation Refer to Figure 1 4 and connect the two wires from the key selector to the terminal BUTT2 and GND J7 on the PCB 2 CONTROL BOX Figure 1 4 PW150 200 Manual Transformer 5 509 amp E amp EX El E Ed E pa ni Rx1 9 OS e Ee TE og y E CONTROL BOX Figure 1 5 N c3 c3 o 0 9 Oo O