1. Model WAPO MAT 170998 Applicable standards EN 61010 1 1993 A2 1995 EN 50081 1 EN 50082 1 DIN 45635 Pt 1 Hiermit wird best tigt da die oben bezeichnete Maschine den genannten EG Richtlinien entspricht Diese Erkl rung wird ung ltig falls die Maschine ohne unsere Zustimmung ver ndert wird This is to confirm that the above mentioned machine complies with the described EC rules This declaration becomes invalid if the machine is modified without our approval Cette machine est conforme aux normes en vigueur de la Communit Europ ene Cet avis est nul et non avenant si cette machine est modifi e sans notre accord Esta m quina anteriormente mencionada cumple con los limites requeridos por el reglamento EC Ahora bien esta declaraci n quedar invalidada en caso de realizar modificaciones al aparato sin nuestra aprobaci n Hiermee wordt bevestigd dat bovengenoemde machine voldoet aan de voorgeschreven EU normen Deze verklaring verliest geldigheid als er zonder onze uitdrukkelijke toestemming wijzigen aan de machine worden aangebracht Place date Hamburg 10 April 2003 Company stamp D A Ur by Signed pu se Wilfried Wassermann Managing Director WASSERMANN DENTAL MASCHINEN WASSERMANN Dental Maschinen GmbH Rudorffweg 15 17 D 21031 Hamburg Tel 49 0 40 730 926 0 Fax 49 0 40 730 37 24 e mail info wassermann dental com Internet http www wassermann dental com
2. Guarantee and responsibility provisions contained in the sales and supply conditions of Wassermann Dental Maschinen GmbH are not extended by these instructions i Ensure that this user manual is accessible at all times and has been read and understood dek WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 3 Application The WAPO MAT is designed for water bath polymerisation All readily available plastics can be polymerised fully automatically slowly up to 12 hours and at high temperature 95 C 4 Before you start 4 1 Unpacking Transport Remove the packing materials and place the unit on a firm level surface Check the accessories are correct see 8 4 When moving the unit ensure that you have disconnected the power cord Use appropriate packing materials to avoid accidental damage 4 2 Set up Storage Setthe machine up on a level surface Use the clip to attach the drain hose supplied firmly to the housing to ensure there is adequate drainage Always set up the equipment with sufficient space around it for working and servicing take its dimensions into consideration Do not set it up out of doors f the unit is to be stored for an extended period protect it from moisture and dust drainage system because the water draining from it can be very hot approx 95 C This also makes it much easier to empty the tank completely for cleaning for example i We recommen
3. User manual Wapo MAT Polymeriser Figure 1 Wapomat C WASSERMANN DENTAL MASCHINEN GMBH de WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor Dear customer Thank you for choosing a product from the Wassermann range Wassermann dental equipment incorporates the highest standards of quality and the latest technology In order to enjoy maximum performance and years of trouble free operation please read this user manual carefully before you start work and operate the unit according to the recommended guidelines Please ensure that all personnel operating the equipment have read and understood this user manual Keep this user manual on hand for ready reference Company address Wassermann Dental Maschinen GmbH Rudorffweg 15 17 D 21031 Hamburg Germany Tel 49 0 40 730 926 0 Fax 49 0 40 730 37 24 email info wassermann dental com URL http www wassermann dental com ide WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 1 FEATURES 3 2 FOR YOUR ET7O2 3 3 2 1 YOUR USER MANUALE 3 2 2 SAFETY GUIDELINES nn ae tee a e ae tre a e tret ps eiaeiiai 4 2 3 RESPONSIBILITY FOR OPERATION AND DAMAGE nne rre nnn trn tren rins 4 3 APPEICATIQN 3 3 rir E yo z coi eade Ea YE eEZ oye eco cea suseascavsee A T 5 4 BEFORE YOU START ek KEREN KEEN KEN RENE KEEN n uk ss RR sa un Rura KEREN 5 4 1 UNPACKING TRANSPORT ree renn nnn ree hin tre trei rie t
4. d installing the polymeriser directly to the 6 WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor Plug in the power cable 230V 50Hz Fill the tank with water up to the white plastic ring max 18 5 litres Turn on the main switch green rocker switch The unit starts heating up immediately to the last stored temperature When the desired temperature is reached the yellow LED goes out and the unit is ready for use Use heat resistant gloves when working with the WAPO MAT The WAPO MAT has a dry run cut out in order to prevent the A heater burning out when there is insufficient water in the tank orange LED A warning signal also sounds while the program is running Make sure that the water level is always above the white plastic ring inside tank otherwise the heater will shut off automatically If the equipment is not to be used for an extended period i disconnect the power plug from the mains switch WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 6 1 Operation 1 oO N O Om P CO flashing Turn on the main switch green rocker switch Place the prepared moulds in the holder Set the desired polymerisation time 2 see 6 2 Set the desired temperature 3 see 6 2 The yellow LED 6 comes on during heating Note The red LEDs indicate the active controls Press the Start Stop button 9 to start polymerisation i
5. e ah VV Polymerisation 1 EE Time 2 Temperature 3 TH Heating 6 E Kal Lowwater 7 PALO Je AM BN ie WASSERMANN DENTAL MASCHINEN iA gt SC Check the water level the orange low water light 7 should not be on or The unit switches off automatically at the end of the polymeriation time 8 LED display 4 Default Plus 5 Current Minus 9 Start Stop 8 WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 6 1 1 Polymerisation choice of 3 times and 3 temperatures The Polymerisation 1 and Set Point 4 LEDs must be on but not Start Stop 7 Use the buttons as described below to set the function This allows you to check and or change stored values 6 1 2 Setting the time 1 Press and hold Time 3 then press Start Stop 7 once The first character on the display 8 flashes to indicate that the Ee value can be changed by pressing Set Point Warn Es 4 or True Value 5 while Time 3 is held T o on Release all three buttons to store the Qd 8 changed value IJ Lg E 2 Store the value by simultaneously pressing 6 3 Polymerisation 1 and Set Point 4 P3 m En Im 3 For the second value press and hold Time 3 again then press Start Stop 7 once aly The second character on the display flashes k 7 Q Fo
6. he above measures do not solve the problem contact your dental depot or our Service department 11 WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 8 Maintenance 8 1 Cleaning The equipment should be cleaned regularly ie clean every 4 weeks with Kalk Ex to guarantee problem free operation Quantity approx 300ccm Kalk Ex per full tank 18 5 litres water If there is considerable limescale present increase the amount of Kalk Ex appropriately The initial supply of Kalk Ex comes with the machine Clean the level sensor white plastic ring in the tank using a nailbrush for example Clean the outside of the unit and any accessories with a sponge and or a soft cloth and mild detergent The model plate must always be legible and must not be removed Warning Leave KALK EX to work for a maximum 12 hours Then drain the tank and rinse thoroughly 8 2 Maintenance The WAPO MAT does not require any special maintenance You just need to keep it clean 12 WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 9 Warranty The warranty period for our equipment is 12 months If faults occur within the warranty period contact your dental depot or get in touch directly with our Service department Your polymeriser should only be operated in perfect condition If faults occur which could harm operators or third parties the unit should not be used until it has been fixed The warranty does not cove
7. llow the same sequence as above 4 The procedure is the same for the third display character Each change needs to be stored 5 If Time 3 is pressed and held and Start Stop 7 pressed a fourth time the total of the three individual times is displayed Times assigned the value zero 0 are ignored 1 il 6 1 3 Setting the temperature Press and hold Temperature 6 then press Start Stop 7 once The first character on the display 8 flashes to indicate that the value can be changed by pressing Set Point 4 or True Value 5 while Temperature 6 is held on Release all three buttons to store the changed value The value is stored by simultaneously pressing Polymerisation 1 and Set Point 4 For the second value press and hold Temperature 6 then press Start Stop 7 once The second character on the display flashes Follow the same sequence as above WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor fr m Au PA Ob ae s em CZ Zee Ge ES A Ba RUD 4 6 POINT VALUE K 7 4 The procedure is the same for the third display character Each change needs to be stored If Temperature 6 is pressed and held and Start Stop 7 pressed a fourth time the first of the three individual temperatures is displayed All recommendations for the use of this instrument whethe
8. r damage caused by improper use external mechanical causes transport damage or interference with the unit by unauthorized persons Spare parts and accessories Spare parts 170601 170625 392008 Rubber foot 32 x 32 H6 black 511091 Hocker switch green Accessories 320030 PVC hose 19 x 4 1500 mm long 322017 Hose protector D20 32 x 12 2 655002 Kalk Ex 1000 ccm 9 1 Repairs Servicing or repairs to the equipment must only be carried out by trained technicians Only original Wassermann spares are to be used Responsibility for the product is voided if altered by unauthorised persons or if inappropriate components are installed SE WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 10 Technical specifications 170998 WAPO MAT Voltage 230 V 50 Hz Power consumption 8A Output 1800 W Capacity max 18 5 L Overall dimensions Width 330 mm Height 460 mm Depth 530 mm Weight 18 5 kg Noise emission x 70 dB A i We reserve the right to make technical changes i WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor EC CONFORMITY CERTIFICATE in accordance with 73 23 EWG low voltage guidelines modified by 93 68 EWG and 89 336 EWG EMV guidelines and 89 392 EWG Machinery guidelines with modifications Manufacturer WASSERMANN Product description Polymeriser for dental Dental Maschinen GmbH applications Rudorffweg 15 17 D 21031 Hamburg
9. r in the form of verbal written or practical instructions are based on our own experience and testing and can therefore only be regarded as guidelines 10 WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 6 2 Storing settings Individual settings can be stored by simultaneously pressing the Polymerisation 1 and Default 4 buttons When you store a setting a YES appears on the LED display The old setting is overwritten each time you store a new one Note You can return to the Wassermann default settings by pressing Polymerisation 1 and Current 5 simultaneously When you store them by pressing Polymerisation 1 and Plus 4 this is confirmed by a YES on the display Polymerisation default settings Time Temperature 6 30 h 70 C 0 00 h 0 C 1 30 h 95 C 7 Troubleshooting Correcting errors Error Likely cause Likely solution WAPO MAT does not heat Low water light and warning tone come on Multi function display does not work correctly Not plugged in Main switch not on Dirty water level sensor Water level too low Fluctuations in power supply 230V 50Hz Check plug and connect to mains if necessary Check and turn on if necessary Clean sensor Fill with water until orange LED goes out and warning tone stops Dirty water level sensor Clean sensor Turn main switch off then on again in about 1 minute Li If t
10. re rsi tre rrsi ris rp nar nnn 5 4 2 SET UP STORAGE ccccecceccceccecccecceccaeececeueecuccuecaueceecaueceecueeaueceeeaeeseeeaeeaeeserens 5 5 START UP EEN 6 c JR d LEE 7 6 1 OPERATION cceccecececcececeececceeeseccecaeececeaeeceecueeaeeceesaeeaeecueeaueceecesaueceesaeeaeesaees 7 6 1 1 Polymerisation choice of 3 times and 3 temperatures 8 6 1 2 Selling the time E 8 8 1 3 Setting the temperature seen a 9 6 27 STORINGSETTINGS ege 10 7 TROUBLESHOOTING CORRECTING ERRORS cerner 10 8 MAINTENANCE CN 11 8 1 GEEANING rare r 11 8 2 MAINTENANCE ann nnnnnnnnnnnnn rre rr naria 11 9 WARRBANHFY as raten Ee 12 SPARE PARTS AND ACCESSORIES ee KEN KKK KEEN KEREN KEREN KEEN Renan KEN 12 9 1 REPAIRS viccvccavccavdeiveesuecavecivcdsvavavcdsccesedcaveviecdewcesvcusueuavedivecevsdewcesneeseecavieavsees 12 10 TECHNICAL SPECIFICATIONS 00ccescceeceecceeceeccescneceeccnsceeccuseneceeseneees 13 EC CONFORMITY CERTIFICAT Bisinccicscsescccsssnssdecinesnseccresscnsacesedunacecsdssanesecevecenecs 14 ue WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor The well proven WAPO MAT polymeriser now with an easy clean multifunction display is a very compact tabletop unit designed for slow high temperature polymerising in a water bath Up to 9 moulds can be cured fully automatically during each polymerisation procedure The unit s stainless
11. steel housing and tank guarantee a long service life It also has a safety cut out to protect the heater in case the water level drops too low 2 For your safety 2 1 Your user manual Configuring and operating this equipment requires precise knowledge and observance of the instructions in this user manual The equipment is designed only for its intended application Important safety symbols used in this manual Warning This is a warning of risk situations and dangers Failure to observe this warning could be life threatening These warnings must be heeded Information This symbol draws your attention to specific features which should be noted s WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 2 2 Safety guidelines This equipment is designed for 230V 50Hz A Make sure it is connected to the correct power supply Disconnect the power cord before carrying out maintenance or cleaning work 2 3 Responsibility for operation and damage The responsibility for operating the equipment lies exclusively with the owner or user if said equipment is incorrectly serviced maintained or altered by persons not employed by an authorized dealer or if the equipment is used in a manner contrary to its specified purpose The equipment must be maintained and operated in accordance with this user manual Wassermann Dental Maschinen GmbH is not responsible for damage arising from the non observance of these instructions

Download Pdf Manuals

image

Related Search

Related Contents

Harman Kardon LAZER LZR303 User's Manual  608DA04_Relazione gestionale  WCS-222 Gembird User Manual  Canon KJ10EX4.5B IRSE User's Manual  MODEL N0: INSTRUCTION MANUAL  IFE Ethernet Interface for LV Circuit Breakers - User Guide  Netis System PE6108G network switch  HP ProBook 4530s  Epson 3100Z Warranty Statement  