Home

Advanced_PC Configuration_en - Service, Support

image

Contents

1. FMS OPC Server DP OPC Server S7 OPC Server S7 OPC Server FF EF OPS FMS Protocol DP Protocol S7 Communic S5 comp comm SEND RECEIVE fil S7 400 cll chy alll li Ml SIMATIC S5 SEND RECEIVE only Ind Ethernet 7 PC G_IK10_del0067s Fig 4 56 System configuration with OPC server a Application Under Windows NT and Win For Industrial Ethernet the Identical and easy to oper dows 2000 Professional OPC OLE for Process Control can be used as an extension to the communications interfaces COM Component Object Model and DCOM Distrib uted COM for the user soft ware The basic principle of OPC is that OPC client applications can communicate with the OPC server through a stan dard open and thus multi ven dor interface Facility for linking to existing OPC capable Windows appli cations Office 97 or HMI sys tems on the market following OPC servers are available S7 OPC servers for S7 communciation alarms and events as well as S5 compatible commun ciation SEND RECEIVE The OPC servers offer the fol lowing Standardized access to SIMATIC S7 and SIMATIC S5 for OPC capa ble applications under Win dows NT and Windows 2000 Professional Integration between auto mation products from differ ent manufacturers in the scope of supply of the communication software Standardized open and vendor independent interface Connection of OPC capable Windows appl
2. CP 5613 Other CPs with polling with events via DP RAM access mm CPU load at same data thruput to get current data of a slave G_IK10_deP0036s Fig 3 104 Comparison of CPU loading for event polling access Performance data of the PROFIBUS CP CP 5613 CP 5613 FO CP 5614 CP 5614 FO CP 5412 A2 CP 5611 CP 5511 Number of connectable DP slaves max 122 122 64 60 60 No of parallel FDL tasks to be processed max 120 120 118 100 32 No of PG OP and S7 connections max 501 501 29 8 8 No of FMS connections max 402 402 32 Note The CP 5613 is the successor type to CP 5412 A2 1 for credit 1 PDU size lt 480 bytes 2 for credit 1 Siemens IK PI October 2000 i Connection possibilities for PG PC 0 eR a OPC servers are supplied with the communication soft ware e Standard open manufac turer independent interface Interfacing of OPC capable Windows applications to S7 communication and S5 compatible communication SEND RECEIVE e Builds upon software pro gramming interfaces Efficient data exchange for Windows NT 4 0 and Windows 2000 Pro e OPC Scout with Browser function as OPC Client and OCX Data Control only S7 OPC server aa b OLE for Process Control can be used as an extension to the communications inter faces COM Component Object Model and DCOM Distributed COM for the user software The basic principle of OPC is that OPC client appli
3. Application tion to PROFIBUS for SIMATIC PG PC and PCs with PCI slot under Windows NT 4 0 and Windows 2000 Professional It can be either a DP master or a DP slave independently of each other The CP 5614 enables connec e PCI card with microproces sor for system interfacing for PCs and SIMATIC program ming devices IPC to PROFIBUS up to 12 Mbit s Communication services PROFIBUS DP master interface according to IEC 61158 EN 50170 on a PCI card PROFIBUS DP slave inter face according to IEC 61158 EN 50 170 on a PCI card PG OP communication with STEP 5 and STEP 7 S7 communication This means that two different PROFIBUS networks can be connected to a PC in a hierar chic structure using one PROFIBUS card and data can be exchanged between the networks 5 compatible communi cation SEND RECEIVE on the basis of the FDL interface PROFIBUS FMS according to IEC 61 158 EN 50170 High performance via direct Dual Port RAM access Event and filter mechanism for relieving the host CPU OPC servers are supplied with the communication soft ware The CP 5614 provides high performance support for con trol tasks on the PC e g PC based control numeric con trol robot control E Design Short PCI card It is connected to the electri It is connected to the optical 2 x 9 pin Sub D sockets for connecting to PROFIBUS e Diagnostic LEDs Parallel opera
4. Enter a Group Name lE_SAM PLE Create Group Active V Update Rate in ms 500 I Extended Cancel Apply Double click on the group entry IE_SAMPLE to open the OPC Browser In the left hand pane you will see the hierarchically arranged name space of the OPC variables SIMATIC NET NCM PC Manual Quick Start 74 C79000 G8976 C 156 01 Quick Start for the OPC Application for Industrial Ethernet Eqjopc navigator oi A x The listed Item s will be added to Group E E Connections O Cument SIMATIC_400 1 _CPU_416 1 Pump2 Current E O EE Motors Sane B SIMATIC_400 1_CPU_416 1 o Emergency SIMATIC_400 1 _CPU_416 1 Pump2 Emergency SIMATIC 400 1 L CPU_416 1 Pump Flow a rata O Flow SIMATIC_400 1 _CPU_416 1 Pump2 Flow SIMATIC_400 1 CPU_416 1 Pump2 Power Power SIMATIC_400 1 _ CPU_416 1 Pump2 Power il Pump is selected 27 04 2001 16 07 4 Select the following OPC items from the appropriate branches in the left hand window and transfer these variables to the right hand pane by clicking on the arrow button Examples SIMATIC_400 1 _CPU_416 1 Machine Speed SIMATIC_400 1 _CPU_416 1 Machine Start SIMATIC_400 1 _ CPU_416 1 Pump1 Flow SIMATIC_400 1 _ CPU_416 1 Pump2 Power The items are added to the group after you confirm the dialog with OK SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 75 Quick Start for the OPC Application for Industrial Ethernet
5. SIMATIC NET NCM PC Manual Quick Start 52 C79000 G8976 C 156 01 Quick Start for the OPC Application for PROFIBUS DP 4 2 5 STEP 7 PC Station Wizard Changing Settings Changing the Hardware and Driver Configuration Activity Change Settings Pcstatin E PCstation Click the Finish button This starts HW Config of SIMATIC STEP 7 SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 53 Quick Start for the OPC Application for PROFIBUS DP 4 2 6 HW Config Inserting a DP Master System CP 5613 as DP Master In the STEP 7 project created by the wizard a SIMATIC PC station was created automatically as an image of the local PC This PC station already includes the OPC server as the basic component for productive communication and the CP 5613 You require a DP master system so that you can assign DP slaves For the DP mode a DP master system must therefore be added to the CP 5613 Activity PCStation Configuration DP_5613_Test 0 PC a I OPC Servet ee 2 CP 5613 Bites Add Ma UISGOnHEG f al HE CP 5613 6GK1 561 334 SS Bee a SS Be Lee a Select the Insert DP Master System menu command SIMATIC NET NCM PC Manual Quick Start 54 C79000 G8976 C 156 01 Quick Start for the OPC Application for PROFIBUS DP 4 2 7 HW Config Inserting a DP Slave ET 200B as DP Slave Activity Open the catalo
6. A DP master and a DP slave library DP_BASE DLL or DPS_BASE DLL offer admin istrative function calls initial ization and management ser vices as well as diagnostic functions A transfer mechanism appli cation in the PC can be set through software as a link for data exchange between the master and slave interface In this manner defined O data can be transferred between the master interface and the slave interface The two connected PROFIBUS networks can be operated with different PROFIBUS bus parameters due to their mutual indepen dence 3 350 0 Siemens IK PI 2001 P Development kit DK 5613 The development kit DK 5613 offers access to the functions DP master class 1 including non cyclic DP expansions With the software develop ment kit DK 5613 the commu nications processors CP 5613 and CP 5614 can be inte grated in any operating sys tem environments The kit contains the necessary source code including the descriptions in PDF format and can be downloaded from the Internet Access to process data with DP 5613 The user interface is compati ble with software package DP 5412 DP master class 1 The CP 5614 operates as a DP master class 1 according to IEC 61158 EN 50170 and handles data transfer with the distributed stations DP slaves completely indepen dently In a fixed repetitive message cycle the central controller exchanges informa tion with the DP slaves
7. H Technical specifications OPC server Product versions Programming e Open and standardized Product contains OPC servers for e Can be used with different DP 5613 PROFIBUS DP manufacturers systems Variable item groups S7 5613 S7 communication Access to One set of variables FMS 5613 FMS communication ENENG ORES 0 SOFTNET S7 for PROFIBUS S7 communication of large data volumes in a short time SOFTNET DP PROFIBUS DP Interfaces e Custom Interface C SOFTNET DP slave PROFIBUS DP slave PC is theref ful OEE r bh ee CP 5613 5614 and S5 compatible communication el Hae ee CP 5613 FO 5614 FO FDL Balen Bley i with DP Base software PROFIBUS DP master therefore easy to use Access to DP slave of the e Graphics with OCX CP 5614 allowing configuration instead of programming Protocols DP protocol e S7 communication e FMS protocol e S5 compatible communication SEND RECEIVE Availability e Windows NT 4 0 2000 is automatically available for all applications after installation Siemens IK PI 2001 Sr e Connection options for PG PC Advanced PC Configuration Overview e Advanced PC Configuration Considerably simplified is included in delivery of the OPC configuration communications software from version 6 0 onwards e Advanced PC Configuration contigs SIEMENS parce cl is delivered with the new Simple handling thanks to configuring tool NCM PC SIMATIC NET automatic software and the Startup Wizar
8. Reading configuration data and Changing the slave address The extended DP functions also include non cyclic access to the parameters and measured values of a slave e g field devices of the pro cess automation intelligent HMI devices This type of slave has to be supplied with extensive parameter data during startup and normal operation DS_READ DS_WRITE DS_DATA_TRANSPORT Connection options for CP 5614 communications processor BE we PG PC eTe tolet Functions continued Software for PG OP communication This software enables pro gramming of the SIMATIC S5 S7 controllers through PROFIBUS in con nection with STEP 5 STEP 7 The PG OP communication for the CP 5614 is already available after installing the CP 5614 DP Base No additional software pack age is needed S5 compatible communica tion SEND RECEIVE based on the FDL interface SEND RECEIVE FDL inter face is already available after installation of the CP 5614 DP Base and offers data exchange services for diag nostics and management No additional software package is needed Software for S7 communication S7 5613 The user interface is compati ble with S7 5412 SIMATIC S7 system compo nents communicate with each other through S7 communica tion The S7 programming interface enables PG PC application programs access to SIMATIC S7 system com ponents The SIMATIC S7 data can be accessed eas
9. SIMATIC NET WinCC Office 97 OPC Manager OPC Client OPC Client OPC servers are supplied with the communication software e Standard open manufac turer independent interface Interfacing of OPC capable Windows applications to S7 communication and S5 compatible communica tion SEND RECEIVE Builds upon software FMS OPC Server DP OPC Server 7 OPC Server S7 OPC Server TLES S a a ZO Oe FMS protocol DP protocol S7 communic S5 com comm ae eee SEND RECEIVE xil ll SIMATIC S7 iL Ih lil Balli LLN ALLU SIMATIC S7 SIMATIC S5 HF SEND RECEIVE only p lt ET 200X F it E a i SIMATIC S5 PROFIBUS Ind Ethernet S7 PC Fig 3 111 System integration with OPC server a Application Under Windows NT OPC The following OPC serversare The same simple to use OLE for Process Control can be used as an extension to the communications inter faces COM Component Object Model and DCOM Distributed COM for the user software The basic principle of OPC is that OPC client applications can communicate with the OPC server through a stan dard open and thus manu facturer independent inter face Connection to OPC compati ble Windows applications already on the market Office 97 or HMI systems is possible available PROFIBUS DP OPC server for PROFIBUS DP FMS OPC server for PROFIBUS FMS
10. The extended DP functions also include non cyclic access to the parameters and measured values of a slave e g field devices of the pro cess automation intelligent HMI devices This type of slave has to be supplied with extensive parameter data during startup and normal operation DS_READ DS_WRITE DS_DATA_TRANSPORT Configuration of PROFIBUS DP takes place with the enclosed COM PROFIBUS PC Edition Functions continued Connection possibilities for CP 5614 communication processor SE Software for PG OP communication This software enables pro gramming of the SIMATIC S5 S7 controllers via PROFIBUS in connection with STEP 5 STEP 7 The PG OP communication for the CP 5614 is already available after installing the CP 5614 DP Base No addi tional software package is needed 5 compatible communica tion SEND RECEIVE based on the FDL interface SEND RECEIVE FDL inter face is already available after installation of the CP 5614 DP Base and offers data exchange services for diag nostics and management No additional software pack age is needed Software for S7 communication S7 5613 The user interface is compati ble with S7 5412 SIMATIC S7 system compo nents communicate with each other via S7 communication The S7 programming inter face enables PG PC applica tion programs access to SIMATIC S7 system compo nents The SIMATIC S7 data can be accessed easily and flexibly The fo
11. in preparation incl acyclic expansions Access to the process data is directly through the Dual Port RAM The Dual Port RAM interface not only offers fast access as a DP master but also a basis for portability to other operating system envi ronments e g VXWorks QNX RMOS Via a library DP_BASE DLL administrative functional calls initialization and manage ment services are offered Development Kit DK 5613 The Development Kit DK 5613 offers access to the functions DP master class 1 including non cyclic DP expansions With the software develop ment kit DK 5613 the commu nication processors CP 5613 and CP 5614 can be inte grated in any operating sys tem environments The kit contains the necessary source code including the descriptions in PDF format and can be downloaded from Internet So seco KIPI Siemens IK PI October 2000 Cis Access to process data with DP 5613 The user interface is compati ble with software package DP 5412 DP master class 1 The CP 5613 operates as a DP master class 1 according to IEC 61158 EN 50170 and handles data transfer with the distributed stations DP slaves completely indepen dently In a fixed repetitive message cycle the central controller exchanges informa tion with the DP slaves e g ET 200S The DP program ming interface DPLib DLL provides the PC programmer with function calls for data transfer In addition the DP interface o
12. No of PG OP and S7 connections max e No of FMS connections max 1 For credit 1 PDU size lt 480 byte 2 For credit 1 Ordering data CP 5614 communications gt processor PCI card with master and slave connection to PROFIBUS incl Windows NT 4 0 WS server Windows 2000 Pro server driver DPRAM Interface for DP master and slave PG and FDL configuration software with electronic manual on CD ROM Development kit 1 DK 5613 Software development kit for CP 5613 CP 5614 for integration in any operating system environments on sys tems with PCI slot 1 Download from the Internet at 9 6 kbit s to 12 Mbit s 9 pin Sub D socket 9 pin Sub D socket 5 V DC 5 1 6A 8 0 W 5 C to 40 C 5 C to 60 C 40 C to 70 C 95 at 25 C PCI card 107 x 168 300 g 1 x PCI slot 122 244 byte each 120 50 1 40 2 Order No 6GK1 561 4AA00 http www siemens de simatic net dk5613 DP 5613 Windows V6 0 gt Software for DP protocol incl PG OP communication FDL DP OPC server NCM PC under Windows NT 4 0 WS server Windows 2000 Pro server for CP 5613 CP 5614 CP 5613 FO CP 5614 FO with electronic manual on CD ROM in German English S7 5613 Windows V6 0 gt Software for S7 communication incl PG OP communication FDL S7 OPC server NCM PC under Windows NT 4 0 WS server Windows 2000 Pro server for CP 5613 CP 5614 CP 5613 FO CP 5614 FO w
13. e Signaling by new kind of event filter mode in the event of changes in the input data of a slave minimum load on host CPU Both alternatives can be com bined Optimum utilization of the PC is therefore possible for the relevant application The new event filter mecha nism can also be used for diagnostic messages from slaves In equidistant mode signal ing by interrupt Start DP cycle End of cyclic data exchange with the DP slaves from hardware version 3 available soon Equidistant operation adjustable with STEP 7 V5 1 or higher or NCM PC V5 1 SP2 Connection options for PG PC POOP CP 5614 FO communications processor BE a Functions continued FastLogic rapid shutdown FastLogic means that the CP5614 FO can react auto matically to up to 4 plant states This achieves a fast response time and indepen dence from the host applica tion e g for rapid equipment shutdown DP programming interface The DP programming inter faces of the CP 5613 and CP 5614 FO are identical The DP programming inter face of the CP 5614 FO has the following functions DP slave DP master class 1 including acyclic DP extensions DP master class 2 available soon incl non cyclic expansions Access to the process data is directly through the dual port RAM The dual port RAM interface not only offers fast access as a DP master slave but also a basis for porta
14. erating systems by a Dual Port RAM interface Fast commissioning by Can also be used in a high Plug amp Play and diagnostic temperature industrial envi tools ronment g Ordering data Order No DP 5613 Windows NT 4 0 2000 Pro gt 6GK1 713 5DB21 3AA0 Software V2 1 for DP protocol on CP 5613 CP 5614 CP 5613 FO CP 5614 FO incl PG FDL and DP OPC server with electronic manual on CD ROM German English S7 5613 Windows NT 4 0 2000 Pro 6GK1 713 5CB21 3AA0 Software V2 1 for S7 communication on CP 5613 CP 5614 CP 5613 FO CP 5614 FO incl PG FDL and S7 OPC server with electronic manual on CD ROM German English FMS 5613 Windows NT 4 0 2000 Pro Software V2 1 for FMS protocol on CP 5613 CP 5614 CP 5613 FO CP 5614 FO incl PG FDL and FMS OPC server with electronic manual on CD ROM German English Manual CP 5613 CP 5614 and SOFTNET for PROFIBUS Including Description of the interfaces FMS DP S7 FDL OPC server configuration tools German e English PROFIBUS FastConnect RS 485 bus connector Plug 180 With 180 cable outlet PROFIBUS bus terminal 12M gt 6GK1 500 0AA10 Bus terminal for connecting PROFIBUS stations up to 12 Mbit s with connecting cable SIMATIC NET Software Update Service For Industrial Ethernet PROFIBUS OPC server including manuals on CD ROM German English gt 6GK1 713 5FB21 3AA0 gt 6GK1 971 5DA00 0AA0 gt 6GK1 971 5DA00 0AA1 gt
15. with electronic manual on CD ROM German English Manual CP 5613 CP 5614 and SOFTNET for PROFIBUS Including Description of the interfaces FMS DP S7 FDL OPC server configuration tools gt 6GK1 713 5CB21 3AA0 gt 6GK1 713 5FB21 3AA0 German gt 6GK1 971 5DA00 0AA0 e English gt 6GK1 971 5DA00 0AA1 PROFIBUS FastConnect gt 6GK1 500 0FC00 RS 485 bus connector Plug 180 With 180 cable outlet PROFIBUS bus terminal 12M gt 6GK1 500 0AA10 Bus terminal for connecting PROFIBUS stations up to 12 Mbit s with connecting cable SIMATIC NET Software Update Service For Industrial Ethernet PROFIBUS OPC server Including manuals on CD ROM German English gt 6GK1 704 0AA00 3AA2 Electronic manuals 6GK1 975 1AA00 3AA0 Communication systems protocols products on CD ROM German English 3 293 Siemens IK PI October 2000 s ae er A SEs The CP 5614 FO enables con nection to PROFIBUS DP for SIMATIC PG PC and Al compatible PCs with PCI slot under Windows NT 4 0 and Windows 2000 Profes sional Application 2 Duplex sockets for connection of plastic and PCF FOCs with 2 simplex plugs each to the optical PROFIBUS 9 pin Sub D socket for con necting to PROFIBUS Connection for external power supply This means data transmission on the optical line is not inter rupted when the PC is switched off Access to process data The CP 5614 is operated as
16. 2 3 5 Configuring Connections 0 cece eee 2 4 Downloading the Configuration Data to the PC Station 2 5 Commissioning Wizard 00 0c cece teens 2 6 PC Station Wizard s rasors evrol ccc ene eens 2 7 Station Configuration Editor 0 00 ccc eee eee 2 7 1 Managing Components Components Tab 2 000ee ee eee 2 7 2 Diagnostics Tabirin eirian e a dire hee eee aie Pg ee 3 Configuring the OPC Server 00 ccc eee eee eee eee eee eee 3 1 Significance of Configuration 0 00 eee 3 2 Configuring the Properties of the OPC Server 0 000 eee 3 3 Configuring Connection Properties for the OPC Server 4 Quick Start for the OPC Application for PROFIBUS DP 4 1 Example of a PROFIBUS Configuration 00ee eee 4 2 Quick Start for PROFIBUS Communication with OPC 4 2 1 Hardware and Software Installation 00 cee eee eee eee 4 2 2 Configuring the PC Station 0 ccc cece eee 4 2 3 STEP 7 Starting the PC Station Wizard 0000 eee aes 4 2 4 STEP 7 PC Station Wizard Selecting the Editing Mode 4 2 5 STEP 7 PC Station Wizard Changing Settings 4 2 6 HW Config Inserting a DP Master System 00ee ee eee 4 2 7 HW Config Inserting a DP Slave 602 cece eee eee ee 4 2 8 HW Config Downloading the Configura
17. 5 2 14 OPC Scout Displaying and Modifying Values of Variables Executing Synchronous Write Jobs Activity Ejorc scout New Project1 File View Server Group Item S wl a eae Servers and groups Items incl status information Servers Item Names Value Type Quality Time Stamp UTC 2 Local Servers 1 SIMATIC_4001_CPU_416_1 Machine_Speed 0 uintl6 good OPC SimaticNET 2 SIMATIC_4001_CPU_416_1 Machine_Start False bool good Group_1 3 p 0 uintlG good New Group 4 SIM 2 Pow MAR o0 amp Bry Remote Servers 04 27 2001 14 23 14 323 04 27 2001 14 23 14 323 0 SIMATIC_4001_CPU_416_1 Pump2 Power Now double click on the Value cell of one of the variables for example on the O of the first OPC item A dialog opens in which you can change the value of the variable Ea write alue s to the Itemfs gt Formatconyversion F Syne write Original C Async write C Hex Binary Cancel Apply Click the OK button to start the write job SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C 156 01 A SIMATIC NET Support and Training Customer Support Technical Support Open round the clock worldwide E a4 Bato as A Ll P Da Nuremberg F Johnson City S f Ue f o 0 Singapore y batt Nis Sie SIMATIC Hotline Worldwide Nuremberg Worldwide Nuremberg Technical Support Technical Supp
18. 6GK1 500 0FC00 gt 6GK1 704 0AA00 3AA2 Electronics manuals gt 6GK1 975 1AA00 3AA0 Communication systems protocols products on CD ROM German English Overview CP 5613 FO communication processor SE PGIPC e PCI card with microproces sor for system interfacing for PCs and SIMATIC PUs PC to the optical PROFIBUS with integrated interface up to 12 Mbit s e Integrated FOC interface for direct FO connection Communication services PROFIBUS DP master according to IEC 61 158 EN 50170 PG OP communication with STEP 5 and STEP 7 7 communication 5 compatible communi cation SEND RECEIVE on the basis of the FDL interface PROFIBUS FMS according to IEC 61 158 EN 50170 age Extensive diagnostic facili ties for installation commis sioning and operation of the module High performance via direct Dual Port RAM access Event and filter mechanism for relieving the host CPU e Multiple protocol operation and parallel operation of up to 4 CPs OPC servers are supplied with the communication soft ware E Application The CP 5613 FO enables con The CP 5613 FO provides nection to the optical PROFIBUS with integrated interface for SIMATIC PG PC and PCs with PCI slot under Windows NT 4 0 and Windows 2000 Professional high performance support for control tasks on the PC e g PC based control numeric control robot con trol E Desi
19. 6GK1 704 5DW60 3AA0 6GK1 704 5SW60 3AA0 6GK1 500 0FC00 6GK1 500 0AA10 6GK1 971 5DA00 0AA0 6GK1 971 5DA00 0AA1 6GK1 704 0AA00 3AA2 6GK1 975 1AA00 3AA0 Connection options for SOFTNET for PROFIBUS rT a a ee PG PC TRAPI tion systems Overview Software for linking pro 8 grammable controllers PCs PG PC SOFTNET and notebooks to automa CP 5611 CP 5511 for 3 PROFIBUS o Can be used in conjunction with CP 5511 PCMCIA CP 5611 PCI and integrat ed PROFIBUS interface of the SIMATIC PG PC PC Communication services PROFIBUS DP master class 1 PROFIBUS DP master class 2 with non cyclic expansions PROFIBUS DP slave PG OP communication S7 communication 5 compatible communi cation SEND RECEIVE based on the FDL inter face f e JO if as 5 115U to S5 155U with CP 5431 FMS DP ml 57 300 with 37 300 with CP 342 5 342 5 or CP 343 5 y ba Fig 3 116 System configuration SOFTNET for PROFIBUS OPC servers are supplied with the communication soft ware A pplication SOFTNET for PROFIBUS can be used to connect PCs to automation systems e g SIMATIC S7 through PROFIBUS The following are available as user interfaces DP protocol PG OP communication for SIMATIC S7 e S7 communication S5 compatible communica tion SEND RECEIVE based on the FDL interface SOFTNET is avai
20. Configuring the OPC Server Quick Start with PROFIBUS DP Configuring the OPC Server Quick Start with Industrial Ethernet Support and Training Glossary Index Classification of the Safety Related Notices gt amp Trademarks This manual contains notices which you should observe to ensure your own personal safety as well as to protect the product and connected equipment These notices are highlighted in the manual by a warning triangle and are marked as follows according to the level of danger Danger indicates that death severe personal injury or substantial property damage will result if proper precautions are not taken Warning indicates that death severe personal injury or substantial property damage can result if proper precautions are not taken Caution indicates that minor personal injury or property damage can result if proper precautions are not taken Vorsicht indicates that property damage can result if proper precautions are not taken Notice highlights important information on the product using the product or part of the documentation that is of particular importance and that can have detrimental results if ignored Note highlights important information on the product using the product or part of the documentation that is of particular importance and that will be of benefit to the user SIMATIC SIMATIC HMI and SIMATI
21. How It Works The Station Configuration Editor manages a diagnostic buffer in which the PC station components hardware and software enter event information You can use this list to analyze configuration or communication problems Note You will find more information on the meaning of the display boxes and the buttons in the integrated help system m SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 37 SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C 156 01 3 Configuring the OPC Server OPC Server With the SIMATIC NET OPC Server described here SIMATIC NET offers you a convenient tool with which your PC applications can write and read process data and receive notification of process events By creating a configuration you can specify the behavior of the OPC Server You then download the configuration data to the PC station with NCM PC This chapter describes the options available to you when configuring the OPC Server with the NCM PC configuration tool Where to Find Further Information e Creating PC stations and configuring connections Please read Section 2 3 in this manual e Using the interface to the OPC Server in PC applications How you address the OPC Server in your PC application and how the PC application reacts to the behavior of the OPC Server is not described in this documentation For more information on this topic please read the detailed OPC documentation provided by S
22. S7 REDCONNECT The S7 programming inter face enables PG PC applica tions e g WinCC and appli cation programs access to SIMATIC S7 M7 system components Thus easy and flexible access to the data of the SIMATIC S7 M7 is possible S7 communication provides Administrative services e Link management e Mini database e Trace Data transfer services READ WRITE variables BSEND BRECEIVE With S7 REDCONNECT communication with the high availability S7 400H system is possible All configuration for S7 communication is per formed using STEP 7 V5 up wards Continuous data throughput through protocol processing on the CP Can be connected to any Ethernet network via AUI ITP or RJ45 ports on the module Software for 5 compatible communica tion SEND RECEIVE This layer 4 based interface is used for communication between PG PC and SIMATIC S5 PG PC and SIMATIC S7 PG PC and PG PC S 5 compatible communica tion SEND RECEIVE pro vides the following services Management services Connection buildup service Data transfer services The software is contained in the products S7 1613 and TF 1613 e The configuration settings for PCs made with STEP 7 are stored in files that are then transferred to the individual PCs Free computer capacity for further applications in the PC e g HMI ISO and TCP IP transport onboard Simple handling through plug amp play and aut
23. Transport storage temperature e Relative humidity max Design e Module format e Dimensions W x H in mm e Weight e Space required approx Performance data Single protocol mode No of connectable DP slaves max Data area of slave interface input data output data diagnostics data o of parallel FDL tasks o be processed max No of PG OP and S7 connections max o of FMS connections max For credit 1 PDU size lt 480 byte For credit 1 N Ordering data CP 5614 FO communications gt processor PCI card with master and slave connection to PROFIBUS incl Windows NT 4 0 WS server Windows 2000 Pro server driver DPRAM Interface for DP master and slave configuration software with electronic manual on CD ROM Development kit 1 DK 5613 Software development kit for CP 5613 CP 5614 for integration in any operating system environments on systems with PCI slot 3 358 8 Siemens IK PI 2001 m a Connection options for PG PC CP 5614 FO communications processor 9 6 kbit s to 12 Mbit s 2 x duplex socket FO 9 pin Sub D socket 9 pin Sub D socket 2 x duplex socket FO Low voltage socket 3 5 mm 1 3 mm He 5 V DC 5 12 V DC 5 16A 0 3 A 8 W 9 12VDC O4A 3 6 4 8 W 5 C to 40 C 5 C to 60 C 40 C to 70 C 95 at 25 C PCI card 107 x 168 300 g 1 x PCI slot 122 244 byte each 120 50 1 402 Order No 6GK1 5
24. and offers data exchange services for diag nostics and management No additional software pack age is needed Connection options for CP 5613 FO communications processor BE PG PC poor i FIELD BUS nn F unctions continued Cc D D onfiguration iagnosis esigned for Industry Software for S7 communication S7 5613 The user interface is compati ble with software S7 5412 SIMATIC S7 system compo nents communicate with each other through S7 communica tion The S7 programming interface enables PG PC application programs access to SIMATIC S7 system com ponents The SIMATIC S7 data can be accessed easily and flexibly The following services are available with S7 communica tion Administrative services Link management Mini database e Trace Data transfer services Reading writing of variables BSEND BRECEIVE up to 64 KB per task Configuration of S7 commu nication protocols S5 compatible communica tion DP protocol DP DPV1 DPV2 and FMS protocol is executed in STEP 7 NCM PC V5 1 SP2 or higher Extensive diagnostic tools are available for installation com missioning and operation for the module itself and for the PROFIBUS network e Fastest possible access to process data through dual port RAM Short response time with FastLogic Process consistent data from a DP cycle e Direct connection to the op tical PROFIBUS throu
25. e g ET 200S The DP pro gramming interface DPLib DLL provides the PC programmer with function calls for data transfer In addi tion the DP interface offers the functions SYNC and FREEZE as well as the activation and deactivation of slaves The DP functional expansions with respect to master class 1 enable non cyclic read and write functions DS_READ DS_WRITE as well as alarm acknowledgement ALARM_ACkK to be per formed parallel to cyclic data traffic The non cyclic trans mitted data e g parameter ization data are changed very rarely in comparison with the cyclic measured values and are transmitted with low priority parallel to the fast cyclic useful data transfer Interrupt acknowledgment in the master ensures reliable transfer of the interrupts from DP slaves DS_READ DS_WRITE DS_DATA_TRANSPORT Parallel operation of DP Base and DP 5613 software is not possible e DP master class 2 In addition to DP master class 1 services the CP 5614 also offers DP master class 2 ser vices in connection with the DP programming interface according to IEC 61 158 EN 50170 Devices of this type programming configu ration or operating devices are used for commissioning configuring the DP system or system operation in normal operation diagnostics The DP programming inter face provides the following services Master diagnostics Slave diagnostics Read inputs outputs of a slave
26. gt Electronic manuals for communication systems protocols products on CD ROM German English 1 Download from the Internet at 6GK1 713 5DB60 3AA0 6GK1 713 5CB60 3AA0 6GK1 713 5FB60 3AA0 6GK1 500 0FC00 6GK1 500 0AA10 6GK1 901 0FB00 0AA0 6GK1 905 6PA10 6ES7 195 1BE00 0XA0 6GK1 971 5DA00 0AA0 6GK1 971 5DA00 0AA1 6GK1 704 0AA00 3AA2 6GK1 975 1AA00 3AA0 http www siemens de simatic net dk5613 Connection options for PG PC CP 5511 communications processor BE gt ptelolet O verview under different software pack ages and allows the user to execute programming device functions and PC functions through PROFIBUS and the multipoint interface MPI Only one CP can be operated for each PG PC notebook Similarly only one protocol PROFIBUS DP S7 communi cation or FDL can be used for each CP For connecting PG PCs and notebooks with PCMCIA slot to PROFIBUS and MPI of the SIMATIC S7 Communication services PROFIBUS DP master class 1 with SOFTNET DP PROFIBUS DP master class 2 including acyclic DP expansions with SOFTNET DP PROFIBUS DP slave with SOFTNET DP slave PG OP communication S7 communication with SOFTNET S7 5 compatible communi cation SEND RECEIVE based on the FDL inter ages support the CP 5511 e STEP 7 as of V3 2 Drivers for the CP 5511 are supplied with STEP 7 SOFTNET S7 The S7 progr
27. optical and electrical inter process data via Dual Port erating systems by a Dual face to master and slave RAM Port RAM interface e Short response time with FastLogic Programming device 5 j H bi with CP py 5 FO l SIMATIC 57 300 with CP 342 5 FO UU optical PROFIBUS DP slave le gt Switchable ____ RS 485 DP master PROFIBUS CP 5614 FO Distributed I O G_IK10_deP0109s Fig 3 108 Configuration example with CP 5614 FO Kyra Siemens IK PI October 2000 s aasa ARJ 3 i Technical specifications Baud Rates Basic interface setting PROFIBUS master e PROFIBUS slave Interfaces switchable by software call PROFIBUS master PROFIBUS slave e External power supply optional via standard external power supply Supply voltage from PCI Current consumption 9 6 Kbit s to 12 Mbit s 2 x Duplex socket FO 9 pin Sub D socket 9 pin Sub D socket 2 x Duplex socket FO Low voltage socket 3 5 mm 1 3 mm 5 VDC 5 12 V DC 5 efrom 5VDC 1 6A e from 12 V DC 0 3 A Power loss 8 W Supply voltage optional 9 12 VDC external power supply e Current consumption 0 4 A e Power loss 3 6 4 8W Perm ambient conditions Operating temperature without fan with fan air current 0 5 m s Transport storage temperature e Relative humidity max Design e Module format e Dimensions W x H in mm e Weight approx e Space required Performance
28. play The user receives up to date data via two access mecha nisms e Cyclic polling of the DP slaves higher load on host CPU Signalling by new kind of event filter mode in the event of changes in the input data of a slave minimum load on host CPU Both alternatives can be com bined Optimum utilization of the PC is therefore possible for the application in question The new event filter mecha nism can also be used for 7 communication 5 compatible communi cation SEND RECEIVE on the basis of the FDL interface PROFIBUS FMS according to IEC 61 158 EN 50170 High performance via direct Dual Port RAM access Event and filter mechanism for relieving the host CPU Multiple protocol operation and parallel operation of up to 4 CPs OPC servers are supplied with the communication soft ware The CP 5614 FO provides high performance support for control tasks on the PC e g PC based control numeric control robot control a Design e Short PCI card Diagnostic LEDs It is connected to the optical PROFIBUS with integrated interface and OBT by Plastic and PCF FOCs with simplex plugs It is connected to the electri cal PROFIBUS by e Plastic and PCF FOC with simplex plugs to an OBT E Functions PROFIBUS DP Event filter mechanism Signalling by Interrupt for diagnostic messages from slaves e In equidistant mode signal ling by interrupt Start DP cycl
29. tion e Time synchronization Continuing to use existing Windows applications Services for monitoring the redundant communication Diagnostics tool for visualiz ing the communication status OPC interface The OPC server contained in the respective software pack age can be used as a standard programming inter face for the protocols S7 com munication and S5 compati ble communication to connect automation applications to OPC capable Windows appli cations Office HMI systems etc via C library The programming interfaces for the protocols S7 communi cation PG OP communica tion S5 compatible communi cation and TF protocol for existing applications are implemented as a Dynamic Link Library DLL The following compilers can therefore be used in conjunc tion with the SIMATIC NET products e Microsoft Visual C C V6 0 e Microsoft Visual Basic V6 0 aes Siemens IKPI October 2000 AECE Industrial Ethernet system interfacing for PG PC S7 REDCONNECT Industrial E Configuration PC with S7 REDCONNECT and 2 x CP 1613 D E li E oz 7 300 EE i 87 400 PLAN am LLL H system 97 i 57 400 H system p 3 til Li 2 d Fig 4 60 Redundant network with S7 400 H and OSM Configuration The configuration established for the PCs with STEP 7 from V5 0 is written to files and transferred to the PCs Designed for Industry Provides protectio
30. 1411 communication processor Industrial Designed for Industry e Universal connection possibilities AUI ITP or RJ45 Optimized for SOFTNET Ideal for small installations E Technical specifications E Ordering data Order No 10 Mbit s CP 1411 ISA card for connecting a PG PC to Industrial Ethernet SOFTNET S7 Windows 98 NT 4 0 2000 Pro Transmission rate gt 6GK1 141 1AA00 Interfaces e Connection to Industrial Ethernet 15 pin Sub D socket autom switching between AUI and Industrial Ethernet pair A e Connection to 10BaseT Supply voltage Current consumption e from 5 V DC approx e from 12 V DC max Power loss Perm ambient conditions Operating temperature Transportation storage temperature RJ45 5 V DC 5 12 V DC 5 100 mA 500 mA 0 5 W 5 C to 40 C 40 C to 70 C Relative humidity max 95 at 25 C Construction e Module format Short AT format e Dimensions H x D in mm 107 x 15 e Weight approx 100g e Space requirements 1 x ISA slot ar ena 2 Siemens IK Pl October 2000 for Industrial Ethernet V3 3 via ISO or TCP IP Software for S5 compatible communica tion SEND RECEIVE and S7 communication incl OPC server for CP 1411 CP 1511 with electronic manual on CD ROM German English e Version up to 8 connections S7 SOFTNET PG Windows 98 gt NT 4 0 2000 Pro for Industrial Ethernet Software V3 3
31. APC As of the SIMATIC NET PC Windows CD 07 2001 a new standard for PC commissioning is available Advanced PC Configuration Automatic software installation Plug and Play for all supported modules and user guided commissioning are also part of Advanced PC Configuration just as greatly simplified OPC configuration and the new SIMATIC NCM PC configuration tool SIMATIC NCM PC allows configuration of SIMATIC NET PC components that is compatible with STEP 7 and serves as a substitute for the previous PC configuration tools COML S7 and COM PROFIBUS PC Edition A common database with STEP 7 ensures comprehensive configuration including all protocols SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 79 Glossary SIMATIC NCM PC SIMATIC NCM PC is a configuration tool that is compatible with STEP 7 and is tailored to the requirements of PC configuration SIMATIC NCM PC provides the full functionality for the following tasks Configuring PC stations and networking them graphically Configuring connections Configuring the DP mode DPVO and DPV1 Setting network parameters for PROFIBUS Downloading configuration data to PC stations Monitoring communication with attached S7 stations using NCM Diagnostics Station Manager With the Station Manager you can configure a PC in much the same way as an S7 station and download the configuration data over the network The Station Manager is the basic component for c
32. Access to e Custom Interface C making OPC performing e Automation interface VB Excel Access Delphi therefore easy to use e Graphics with OCX therefore parameterization instead of programming Interfaces DP protocol e S7 communication e FMS protocol S5 compatible communication SEND RECEIVE Windows NT 4 0 2000 Profes sional is automatically available for all applications after installa tion Protocols Availability 4 114 4 4L Siemens IK PI October 2000 Oo SOFTNET S7 Industrial Ethernet contains OPC servers for S7 communication S5 compatible communications S5 compatible communications S7 communication Industrial Ethernet System interfacing for PG PC CP 1613 communication processor Industrial Overview PCI card with microproces OPC servers are supplied A sor for connecting PG PC to with the communication Industrial Ethernet with software 10 100 Mbit s autosensing 15 pin AUI ITP e Communication services via e RJ45 connection ISO or TCP IP transport protocols ISO and TCP IP transport PG OP communication protocol onboard S7 communication Large quantity framework 5 compatible communi up to 160 connections with cation SEND RECEIVE ISO up to 64 connections TF protocol with TCP IP Application The CP 1613 enables connec SIMATIC PG Industrial PC and tion to Industrial Ethernet PCs with P
33. DPS_BASE DLL offer admin istrative function calls initial ization and management ser vices as well as diagnostic functions A transfer mechanism appli cation in the PC can be set by software as a link for data exchange between the mas ter and slave interface In this manner defined O data can be transferred between the master interface and the slave interface The two connected PROFI BUS networks can be oper ated with different PROFIBUS bus parameters due to their mutual independence a KIPET Siemens IK PI October 2000 O Development Kit DK 5613 The Development Kit DK 5613 offers access to the functions DP master class 1 including non cyclic DP expansions With the software develop ment kit DK 5613 the commu nication processors CP 5613 and CP 5614 can be inte grated in any operating sys tem environments The kit contains the necessary source code including the descriptions in PDF format and can be downloaded from Internet Access to process data with DP 5613 The user interface is compati ble with software package DP 5412 DP master class 1 The CP 5614 operates as a DP master class 1 according to IEC 61158 EN 50170 and handles data transfer with the distributed stations DP slaves completely indepen dently In a fixed repetitive message cycle the central controller exchanges informa tion with the DP slaves e g ET 200S The DP programming interface DPLib DLL pro
34. IK PI October 2000 ey a Connection options for Overview YUP Alive AD WW A Recommended solution for gt PC based control systems Soft Control PLC Numeric 4 Control Robot Control f s gt Process control systems CP 5613 FO PCI Human Machine Interface HMI E gt PROFIBUS systems with a P large quantity framework more than 8 stations gt Multi protocol operation gt Use of several CPs in one computer gt Versions with Fiber ot Optic interface FO CP 5614 FO PCI CP 5613 PCI SIMATIC fi in Ei Papen a i SIMATIC CP 5614 PCI You will find software for the PC products under Windows on the SIMATIC NET Windows CD including the appropriate manuals in pdf format and other detailed information on SIMATIC NET products and communication Recommended solution for gt Configuration tools e g STEP 7 gt PROFIBUS DP diagnostics station e g with COM PROFIBUS or as a DP master class 2 gt PROFIBUS DP slave connection gt PROFIBUS systems with up to 8 stations gt Monoprotocol mode The necessary configuration tools are contained in all software packages G_IK10_deP0052s Fig 3 108 System interfacing for PG PC Siemens IK PI 2001 Connection options for Performance data overview Performance of the The maximum data through PROFIBUS CP put indicates how many digital input output files can b
35. It is also possible to transfer the configuration data in the form of an XDB database that is also created with the Station Configuration Editor The OPC server and its protocol specific adapters are optional elements and are shown with broken lines SIMATIC NET PC Software CD 07 2001 88 79220 A5822 X 01 7419 SIMATIC NET PC Software CD 07 2001 4 2 2 Configurations up to SIMATIC NET CD 05 2000 Description A configuration created with the tools of the SIMATIC NET product CDs up to and including SIMATIC NET CD 05 2000 will be called the previous configuration in the description below Previous Configuration with LDB Databases Each protocol of each module required its own database If the OPC server was used it also required its own databases in TXT format for each protocol l OPC DP_ f l OPC FMS p l OPC S7 adapter _ adapter adapter ioe Bern eo SIMATIC NET PC Software CD 07 2001 79220 A5822 X 01 7419 89 SIMATIC NET PC Software CD 07 2001 Previous Configuration with LDB and XDB Databases Even when the entire communication of all modules for the S7 protocol was stored in the XDB database separate databases were required for DP and FMS An optional OPC server also had its own data storage T OPC DP TopcrMs l OPC S7 adapter adapter adapter ASSPiSuE ISES Lester SIMATIC NET PC Software CD 07 2001 90 79220 A5822 X 01 7419 SIMATIC NET PC Software CD 07 2001 4 2 3 Configuration
36. MPI 1 PROFIBUS 1 Ethernet 1 Press F1 to get Help Table 2 3 Tool Utility use on Configuration Station Networked PC Station SIMATIC NCM PC STEP 7 yes no is installed Station Configuration Editor no yes e to import an XDB file optional e can be used to match the actual configuration of aPC station toa planned configuration Commissioning Wizard no recommended e for setting up modules for productive communication PC Station Wizard recommended recommended e to edit a stored e to import an XDB file configuration e to create anew configuration SIMATIC NET NCM PC Manual Quick Start 16 C79000 G8976 C 156 01 Configuring SIMATIC PC Stations 2 3 Configuring with SIMATIC NCM PC This chapter will familiarize you with the basic functions of SIMATIC NCM PC What the NCM PC Configuration Tool Does The SIMATIC NCM PC Manager is a version of STEP 7 tailored for configuring PCs It provides the functionality with which you can perform the following tasks for PC stations Configure communication properties of the SIMATIC NET OPC Server Configure connections Configure the DP mode Set network parameters for PROFIBUS and Ethernet operation Download configuration data to PC stations Monitor communication to attached S7 stations with NCM Diagnostics Further Information in Help You will also find detailed information in the integrated help by selecting the menu command Help gt Introduction Conta
37. Mbit s Integrated FOC interface for direct FO connection Communication services PROFIBUS DP master ac cording to IEC 61158 EN 50170 PG OP communication with STEP 5 and STEP 7 S7 communication 5 compatible communi cation SEND RECEIVE on the basis of the FDL interface PROFIBUS FMS according to IEC 61 158 EN 50170 pAnar Extensive diagnostic facili ties for installation commis sioning and operation of the module High performance through direct dual port RAM access Event and filter mechanism for relieving the host CPU Multiple protocol operation and parallel operation of up to 4 CPs e OPC servers are supplied with the communication soft ware Application nection to the optical PROFIBUS with integrated interface for SIMATIC PG PC and PCs with PCI slot under Windows NT 4 0 and Windows 2000 The CP 5613 FO enables con The CP 5613 FO provides high performance support for control tasks on the PC e g PC based control numeric control robot control El Design Short PCI card Diagnostic LEDs It is connected to the optical 2 duplex sockets for con nection of plastic and PCF FOCs with 2 simplex plugs each to the optical PROFIBUS Connection for external power supply This means data transmission on the op tical line is not interrupted when the PC is switched off e Parallel operation of up to 4 CPs The module is installed
38. Ordering data Order No 6GK1 561 1AA00 6GK1 561 1AM00 6GK1 704 5CW53 3AA0 6GK1 704 5DW53 3AA0 6GK1 704 5SW12 3AA0 6GK1 500 0FC00 6GK1 500 0AA10 6GK1 971 5DA00 0AA0 6GK1 971 5DA00 0AA1 6GK1 704 0AA00 3AA2 6GK1 975 1AA00 3AA0 Overview Software for linking pro grammable controllers PCs EE and notebooks to automa tion systems e Can be used in conjunction with CP 5511 PCMCIA CP 5611 PCI and integrat ed PROFIBUS interface of the SIMATIC PG PC PC e Communication services PROFIBUS DP master class 1 PROFIBUS DP master class 2 with non cyclic ex pansions PROFIBUS DP slave PG OP communication 7 communication 5 compatible communi cation SEND RECEIVE based on the FDL inter face CP 5611 CP 5511 s 2 amp BA lt e EE PG PC SOFTNET for 3 PROFIBUS a cay NS t i x l gt 5 115U bis 55 155U with CP 5431 FMS DP A 7 300 with CP 342 5 or CP 343 5 fall _ 7 400 with CP 443 5 Fig 3 109 System configuration SOFTNET for PROFIBUS e OPC servers are supplied with the communication soft ware SOFTNET for PROFIBUS can be used to connect PCs to automation systems e g SIMATIC S7 via PROFIBUS The following are available as user interfaces Application e DP protocol PG OP communication for SIMATIC S7 S7 communication 5 compatible communica tion SE
39. Pe iG alern mh ay PS Alan mes WAYS eIteT COnnesuGh Est DETauIt BiGiwITGT alan nessages SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 45 Configuring the OPC Server ISO Transport Connection SEND RECEIVE Interface Properties ISO transport connection j oO Wpimzaton GNGIEGl access Varraule services ISO on TCP Connection SEND RECEIVE Interface Properties 1SO on TCP connection J Gptinization of diect access vanene services SIMATIC NET NCM PC Manual Quick Start 46 C79000 G8976 C 156 01 4 Quick Start for the OPC Application for PROFIBUS DP 4 1 Example of a PROFIBUS Configuration How does a communication system with PROFIBUS appear Below you will find an example of a communication system using PROFIBUS Typical communication partners are attached to the PROFIBUS network and they can be reached over the OPC Server 57 400 55 AG 95 U 3 5 Seige if AG PCIPG f ib mit CP 5613 k ee 2 OPC Interface ET 200 B 37 300 Example of a PROFIBUS Configuration Communication takes place between two devices or modules Communication in this sense means the transfer of data between two communication partners with different characteristics controlling the communication partner and querying the operating state of the partner Communication with an ET 200 B is described in detail SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01
40. S5 S7 controllers via PROFIBUS in connection with STEP 5 STEP 7 The PG OP communication for the CP 5613 FO is already available after installing the CP 5613 FO DP Base No additional software package is needed 5 compatible communica tion SEND RECEIVE based on the FDL interface SEND RECEIVE FDL inter face is already available after installation of the CP 5613 FO DP Base and offers data exchange services for diag nostics and management No additional software package is needed Functions continued CP 5613 FO communication processor SE Software for S7 communication S7 5613 The user interface is compati ble with software S7 5412 SIMATIC S7 system compo nents communicate with each other via S7 communication The S7 programming inter face enables PG PC applica tion programs access to SIMATIC S7 system compo nents The SIMATIC S7 data can be accessed easily and flexibly The following services are available with S7 communica tion Administrative services e Link management Mini database Trace Data transfer services Reading writing of variables BSEND BRECEIVE up to 64 Kbytes per task PG PC Software for PROFIBUS FMS interface FMS 5613 The user interface is compati ble with software FMS 5412 With the FMS programming interface Al compatible PCs can exchange data with FMS capable controllers e g S5 S7 and field devices of other manufacturers The
41. SIMATIC NET PC Software CD 07 2001 86 79220 A5822 X 01 7419 SIMATIC NET PC Software CD 07 2001 The Tools of Advanced PC Configuration Advanced PC Configuration includes the following tools e Commissioning Wizard The Commissioning Wizard allows simple and consistent commissioning of all modules and user programs supported by Advanced PC Configuration It guides the user step by step through the installation and configuration of the PC station e Configuration Console The Configuration Console is a snap in program embedded in the Microsoft Management Console MMC and provides a wide range of options for configuring PC hardware components and PC user programs as well as providing diagnostic functions Settings for the OPC servers that ship with the communication software are also made in the Configuration Console e SIMATIC NCM PC With SIMATIC NCM PC V5 1 Service Pack 2 a new configuration tool for STEP 7 compatible PC configuration is available e Station Configuration Editor The Station Configuration Editor is the user interface of the Station Manager it allows access to the component management of the PC station In this sense components are the modules and user programs involved in communication tasks The Station Configuration Editor can also be used for diagnostic purposes Supported Modules You will find a list of modules supported and not supported by Advanced PC Configuration in the hinw_e rtf file on the SIMATI
42. SOFTNET S7 SIMATIC S7 system compo nents communicate with each other via S7 communication The S7 programming inter face enables PG PC applica tion programs access to SIMATIC S7 system compo nents The SIMATIC S7 data can be accessed easily and flexibly The following services are available with S7 communica tion Administrative services Link management e Mini database Trace Data transfer services Reading writing of variables BSEND BRECEIVE up to 64 Kbytes per task a 2 6102 Siemens IK PI October 2000 The complete configuration of the S7 communication is per formed using STEP 7 V5 0 SP3 and higher The configu rations generated for the PCs using STEP 7 are stored in files which are subsequently transferred to the individual PCs Software for S5 compatible communica tion SEND RECEIVE based on the FDL interface This layer 2 based interface is used for communication between PG PC and SIMATIC S5 PG PC and SIMATIC S7 PG PC and PG PC SEND RECEIVE offers the fol lowing services Management services Connection establishment services Data transfer services This interface is contained in SOFTNET DP and SOFTNET S7 Configuration is not nec essary User interfaces OPC interface The OPC server contained in the respective software pack age can be used as a stan dard programming interface for the protocols PROFIBUS DP S7 communication and
43. Siemens office Topic Document Basic information for technical STEP 7 basics with personnel using the STEP 7 e User Manual standard software for control tasks with S7 300 400 i Frogiariming Manual programmable controllers e Manual for converting from S5 to S7 e Primer for a fast start Validity of this Manual The information in this manual applies to e Version 5 1 SP2 and higher of the SIMATIC NCM PC STEP 7 configuration software with the NCM S7 for Industrial Ethernet PROFIBUS options e CD 7 2001 and higher from SIMATIC NET Conventions References to other manuals and documentation are indicated by numbers in slashes These numbers refer to the titles of manuals listed in the References section of the Appendix m SIMATIC NET NCM PC Manual Quick Start 6 C79000 G8976 C 156 01 Contents 1 Introduction and Notes on Switching to Advanced PC Configuration 2 Configuring SIMATIC PC Stations 2 cc cece eee eee eee 2 1 Tools and UNES sc cht petal aheus ale pat Gunde babe aaled Bidens 2 2 Using tools Station Configuration Options 20 200 2 3 Configuring with SIMATIC NOM PC 0 cece cence eee 2 3 1 Relationship Between SIMATIC NCM PC and STEP 7 2 3 2 Creating a PC Station 0 cece neeaae 2 3 3 Configuring a PC Station with HW Config 0 0 c cece eee 2 3 4 Creating a DP Master System 0000 e cece
44. Use of Symbol Files Activity SIMATIC NET Commissioning Wizard x Symbols eo Here you specify whether and which symbolic names will be used for X communication If you want to use symbolic names for the variables you must create a symbol file Please enter the name of an existing symbol file or create a new symbol file with the Symbol File Configurator C Do not use a symbol file Use a symbol file File name C MySymbolFile ssd Browse Create modify the symbol file with the Symbol File Configurator Start Additional settings for PROFInet and SIMOTION Advanced Symbols Cancel Help SIMATIC NET NCM PC Manual Quick Start 70 C79000 G8976 C 156 01 Quick Start for the OPC Application for Industrial Ethernet Click the Start button to start the Symbol File Configurator Click the Next button only after the symbol file has been created with the Symbol File Configurator and the file name of the created file has been entered 5 2 10 Symbol File Configurator Inserting a New Program To create a symbol file with the Symbol File Configurator the programs and therefore the symbol definitions must be selected in a STEP 7 project The Symbol File Configurator then automatically enters the content of the symbol table and the definition of the data blocks of the STEP 7 program in the file To insert a program the corresponding S7 device must be linked to a PC station over
45. Windows on the SIMATIC NET Windows CD including the appropriate manuals in pdf format and other detailed information about SIMATIC NET products and communication CP 5511 PCMCIA Recommended solution for gt Configuration tools e g STEP 7 gt PROFIBUS DP diagnostics station e g with COM PROFIBUS or as a DP mas ter class 2 gt PROFIBUS DP slave connection gt PROFIBUS systems with up to 8 stations gt Monoprotocol mode The necessary configuration tools are contained in all software packages G_IK10_deP0052s Fig 3 102 System interfacing for PG PC Siemens IK PI October 2000 Connection possibilities for PG PC AOE Performance of the The maximum data through PROFIBUS CP put indicates how many digital input output files can be read or written to or from the i PROFIBUS application in O o 1 ms via the applicable PROFIBUS CP regardless of E the physical characteristics of the bus CP 5613 with CP 5613 with CP 5412 A2 with CP 5X11 with DP RAM access DP 5613 Win NT DP 5412 Win NT SOFTNET DP G_IK10_deP0035s 1 The CP 5613 is the successor type to CP 5412 A2 Fig 3 103 Performance in the case of almost equal CPU loading CPU loading and A comparison of event access time access via Interrupt and polling access shows that the CPU loading in CP 5613 can be reduced considerably using the event filter mecha nism at the same data throughput
46. a PROFIBUS DP master and slave module which holds the process image input output and diagnostic data in the Dual Port RAM The high per formance data exchange with the PROFIBUS slaves is han dled independently by the CP 5614 FO hardware The user has direct access to the Dual Port RAM The process data of the slaves are always consistent i e the user gets the data from one and the same DP cycle Parallel operation of DP 5613 DP master and DP Base DP master DP slave is not possi ble 3 294 Siemens IK PI October 2000 Oo p po e PCI card with microproces sor for system interfacing for PCs and SIMATIC PUs PC to the optical PROFIBUS with integrated interface up to 12 Mbit s Integrated FOC interface for direct FO connection e Communication services PROFIBUS DP master interface according to IEC 61158 EN 50 170 on a PCI card PROFIBUS DP slave inter face according to IEC 61158 EN 50 170 on a PCI card PG OP communication with STEP 5 and STEP 7 It can be either a DP master or a DP slave independently of each other In this way two dif ferent PROFIBUS networks can be connected in a hierar chical structure to one PC with a PROFIBUS card and can exchange data Parallel operation of up to 4 CPs e The software can switch as signment of master and slave to the optical and elec trical interface The module is installed via PCI standard mechanisms plug amp
47. an S7 connection as in this example Activity The dialog for selecting a new program opens Select the STEP 7 project in which the program was defined in the left hand pane of the window This is a project you created and contains the PC station and the S7 400 device Available Project s E Simatic Projects 2 ZEnO1_02_STEP7_STL_1 10 12 ZEn01_01_STEP _STL_1 9 ZDtO1_11_STEP7__Com_SFC1 ZDt01_10_5TEP 7 _Com_SFB zZDt01_09_5TEP7 _Zebra 2Dt01_08_STEP _ Mischen ZDt01_07_STEP7 _DezP_11 iz 2Dt01_06_STEP _KOP_1 10 2Dt01_05_ STEP _KOP_1 9 zy Sample_lE B S SIMATIC PC Station 1 Bll SIMATIC 400 1 El gj CPU 416 1 S Programm 3 ooga m e SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 71 Quick Start for the OPC Application for Industrial Ethernet Click the OK button These symbolic names are now extracted from the STEP 7 project and entered in a symbol file The dialog is closed and the symbolic name space that has been created is displayed in the main window Save the symbol file and close the Symbol File Configurator 5 2 11 SIMATIC NET Commissioning Wizard Completing Commissioning Activity When you closed the Symbol File Configurator the path to the symbol file was entered in the Symbols dialog of the Commissioning Wizard Now click the Next bu
48. from a DP cycle erating systems by a Dual 4 Fastest possible access to Higher computing perfor Port RAM interface process data via Dual Port mance in the PC by relieving Can also be used in a high RAM the host CPU temperature industrial envi Short response time with Fast commissioning by ronment FastLogic Plug amp Play and diagnostic tools Programming device 4 i 4 E Ee 4 3 SIMATIC S7 300 with CP 342 5 DP master ma 1 eee Transfer mecha nism RS 485 Distributed 1 0 SIMATIC ET 200S G_IK10_deP0110s Fig 3 107 Configuration example with CP 5614 3 292 J Siemens IK PI October 2000 po CP 5614 communication processor a Technical specifications Baud Rates 9 6 Kbit s to 12 Mbit s Interfaces connection PROFIBUS DP master PROFIBUS DP slave 9 pin Sub D socket 9 pin Sub D socket Supply voltage from PCI 5V DC 5 Current consumption from 5 V DC approx 1 6 A Power loss approx 8 0 W Perm ambient conditions Operating temperature without fan with fan air current 0 5 m s Transport storage temperature 5 C to 40 C 5 C to 60 C 40 C to 70 C Relative humidity max 95 at 25 C Design e Module format PCI card e Dimensions W x H in mm 107 x 168 e Weight approx 300g e Space required 1 x PCI slot Performance data Single protocol mode Number of connectable DP slaves max 122 e Data area
49. mA max 360 mA 1 8 W 5 C to 40 C 20 C to 60 C 95 at 25 C PCMCIA type II 54 x 85 x5 30g 130 g 1 x PCMCIA slot type II 3 300 Li Siemens IK PI October 2000 ey oo i Communication processor CP 5511 PCMCIA card for connecting a PG or PC to PROFIBUS or MPI SOFTNET S7 Windows 98 NT 4 0 gt 2000 Pro Software V5 3 for S7 communication incl FDL and S7 OPC server with electronic manual on CD ROM SOFTNET DP Windows 98 NT 4 0 gt 2000 Pro Software V5 3 for DP protocol incl FDL and DP OPC server with electronic manual on CD ROM 6GK1 704 5CW53 3AA0 6GK1 704 5DW53 3AA0 SOFTNET DP slave Windows 98 NT 4 0 2000 Pro Software V1 2 for DP slave incl OPC server with electronic manual on CD ROM PROFIBUS FastConnect gt RS 485 bus connector Plug 180 With 180 cable outlet Manual CP 5613 CP 5614 and SOFTNET for PROFIBUS Including Description of the interfaces FMS DP S7 FDL OPC server configuration tools German e English SIMATIC NET gt Software Update Service For Industrial Ethernet PROFIBUS OPC server including manuals on CD ROM German English vy Electronics Manuals gt Communication systems protocols products on CD ROM German English 6GK1 704 5SW12 3AA0 6GK1 500 0FCOO 6GK1 971 5DA00 0AA0 6GK1 971 5DA00 0AA1 6GK1 704 0AA00 3AA2 6GK1 975 1AA00 3AA0 The CP 5611 enables the con necti
50. manual on CD ROM in German English S7 5613 Windows V6 0 gt 6GK1 713 5CB60 3AA0 Software for S7 communication incl PG OP communication FDL S7 OPC server NCM PC under Windows NT 4 0 WS server Windows 2000 Pro server for CP 5613 CP 5614 CP 5613 FO CP 5614 FO with electronic manual on CD ROM in German English FMS 5613 Windows V6 0 gt 6GK1 713 5FB60 3AA0 Software for FMS protocol incl PG OP communication FDL FMS OPC server NCM PC under Windows NT 4 0 WS server Windows 2000 Pro server for CP 5613 CP 5614 CP 5613 FO CP 5614 FO with electronic manual on CD ROM in German English Manual CP 5613 CP 5614 and SOFTNET for PROFIBUS Paper version Including Description of the interfaces FMS DP S7 FDL OPC server configuration tools gt 6GK1 713 5DB60 3AA0 e German gt 6GK1 971 5DA00 0AA0 e English gt 6GK1 971 5DA00 0AA1 SIMATIC NET gt 6GK1 704 0AA00 3AA2 Software Update Service For Industrial Ethernet PROFIBUS OPC server including manuals on CD ROM German English SIMATIC NET Manual Collection 6GK1 975 1AA00 3AA0 Electronic manuals for communication systems protocols products on CD ROM German English 1 Download from the Internet at http Avww siemens de simatic net dk5613 Connection options for CP 5614 communications processor BE gt PG PC eTaloley Overview Application The CP 5614 supports con nectio
51. master interface and the slave interface The two connected PROFI BUS networks can be oper ated with different PROFIBUS bus parameters due to their mutual independence Development Kit DK 5613 The Development Kit DK 5613 offers access to the functions DP master class 1 including non cyclic DP expansions With the software develop ment kit DK 5613 the commu nication processors CP 5613 and CP 5614 can be inte grated in any operating sys tem environments The kit contains the necessary source code including the descriptions in PDF format and can be downloaded from Internet Access to process data with DP 5613 The user interface is compati ble with software package DP 5412 DP master class 1 The CP 5614 FO operates as a DP master class 1 accord ing to IEC 61158 EN 50170 and handles data transfer with the distributed stations DP slaves completely indepen dently In a fixed repetitive message cycle the central controller exchanges informa tion with the DP slaves e g ET 200S The DP program ming interface DPLib DLL provides the PC programmer with function calls for data transfer In addition the DP interface offers the functions SYNC and FREEZE as well as the activation and deactiva tion of slaves The DP functional expansions with respect to master class 1 enable non cyclic read and write functions DS_READ DS_WRITE as well as alarm acknowledgement ALARM_ACK to be per formed paral
52. modules in your PC will be used automatically in a a STEP 7 project Setting for the Ethernet module CP1613 Use module for productive operation in configured PC station Name crt 613 Index 4 M MAC address 08 00 06 08 62 58 f Change IP address en AGS OO You can only modify the i module parameters by o 0 Subnet mask 255 255 adapting the configuration Standard gateway 172 16 0 1 Use module for PG operation only H Cancel Help Leave the defaults as they are and click Next On the next page confirm the configuration of the modules by clicking Next This saves the configuration and you can no longer go back You have now made the following settings in the dialog e The module will be used for productive communication This requires a configuration that will be created with SIMATIC NCM PC or STEP 7 e The module will be initialized with the MAC address 08 00 06 01 55 06 This means that it would be possible to download to the PC station over Industrial Ethernet from an engineering station with SIMATIC NCM PC or STEP 7 In this example SIMATIC NCM PC is installed locally and a download over the network is not necessary e Index 4 is the identification number for internal addressing of the module within the PC station Each configured component of a PC station has a unique index During configuration the index can be set using SIMATIC STEP HW Config
53. new PC stations You can configure communication connections from these PC stations to existing S7 stations The restrictions in SIMATIC NCM PC relate to the S7 station types that can be configured and programming You can see the differences in the following graphic SIMATIC NCM PC STEP 7 e SIMATIC PC station e SIMATIC PC station e PG PC e PG PC e Other station e Other station e SIMATIC S5 N e SIMATIC S5 e SIMATIC 400 station after data import can be used e SIMATIC 300 station for configuring connections e SIMATIC H station e SIMATIC 400 station e SIMATIC 300 station e SIMATIC H station The types of stations that you can configure only in STEP 7 can be used in SIMATIC NCM PC as target stations for a connection configuration after importing the project After working on such a project in SIMATIC NCM PC you can return it to STEP 7 and edit it again at any time SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 Configuring SIMATIC PC Stations 2 3 2 Aims Creating a PC Station You want to create configuration data for communication services for individual PC stations This configuration data will then be downloaded to the PC station After this the PC applications can use the communications services Tip Remember that you can create a great deal of the project structure automatically using the PC Station Wizard Read the information on starting and working wit
54. not possible the PROFIBUS configuration must be recreated with SIMATIC NCM PC V5 1 Service Pack 2 or STEP 7 Version 5 1 Service Pack 2 or higher COML S7 Continued use not possible the configuration must be recreated with SIMATIC NCM PC V5 1 Service Pack 2 or STEP 7 Version 5 1 Service Pack 2 or higher S7 XDB STEP 7 Continued use possible the XDB database must be imported SEND TXT Text Editor Continued use not possible the RECEIVE configuration must be recreated with SIMATIC NCM PC V5 1 Service Pack 2 or STEP 7 Version 5 1 Service Pack 2 or higher TF LDB COML TF Continued use possible as previously with COML TF Note If you want to continue using the previous configuration tools use the SIMATIC NET CD 05 2000 SIMATIC NET PC Software CD 07 2001 79220 A5822 X 01 7419 SIMATIC NET PC Software CD 07 2001 4 3 Industrial Ethernet Effects on Older Product Versions SIMATIC NET CD 05 2000 and earlier Introduction This section describes what changes are necessary in Industrial Ethernet systems if you are already using a SIMATIC NET CD 05 2000 product or a previous version PG 1413 S7 1413 TF 1413 up to version 5 2 with Service Pack 2 for Windows NT 4 0 or Windows 98 Situation These products are not supported by the SIMATIC NET CD 07 2001 Simultaneous installation of these products with products of the new CD 07 2001 is not permitted and is prevented Steps to take Keep using the products of th
55. of PCI card CP 5611 and MPI cable 5m SOFTNET S7 Windows V6 0 gt Software for S7 communication incl FDL S7 OPC server NCM PC under Windows NT 4 0 WS server Windows 2000 Pro server for CP 5511 and CP 5611 with electronic manual on CD ROM SOFTNET DP Windows V6 0 gt Software for DP protocol master class 1 and 2 FDL incl DP OPC server NCM PC under Windows NT 4 0 WS server Windows 2000 Pro server for CP 5511 and CP 5611 with electronic manual on CD ROM SOFTNET DP Slave Windows V6 0 gt Software for DP slave incl OPC server under Windows NT 4 0 WS server Windows 2000 Pro server for CP 5511 and CP 5611 with electronic manual on CD ROM PROFIBUS FastConnect gt RS 485 bus connector Plug 180 With 180 cable outlet PROFIBUS 12M bus terminal gt Bus terminal for connecting PROFIBUS stations up to 12 Mbit s with connecting cable Manual CP 5613 CP 5614 and SOFTNET for PROFIBUS Paper version Including Description of the interfaces FMS DP S7 FDL OPC server configuration tools German gt English gt SIMATIC NET gt Software Update Service For Industrial Ethernet PROFIBUS OPC server including manuals on CD ROM German English SIMATIC NET Manual Collection gt Electronic manuals for communication systems protocols products on CD ROM German English E Ordering data Order No gt 6GK1 561 1AA00 6GK1 561 1 AM00 6GK1 704 5CW60 3AA0
56. of a slave e g field devices of the pro cess automation intelligent HMI devices This type of slave must be supplied with extensive parameter data during startup and normal operation DS_READ DS_WRITE DS_DATA_TRANSPORT Configuration of PROFIBUS DP takes place with the enclosed COM PROFIBUS PC Edition Software for PG OP communication This software enables pro gramming of the SIMATIC S5 S7 controllers via PROFIBUS in connection with STEP 5 STEP 7 The PG OP communication for the CP 5613 is already available after installing the CP 5613 DP Base No addi tional software package is needed 5 compatible communica tion SEND RECEIVE based on the FDL interface SEND RECEIVE FDL inter face is already available after installation of the CP 5613 DP Base and offers data exchange services for diag nostics and management No additional software pack age is needed Connection possibilities for CP 5613 communication processor SE Software for S7 communication S7 5613 The user interface is compati ble with software 7 5412 SIMATIC S7 system compo nents communicate with each other via S7 communication The S7 programming inter face enables PG PC applica tion programs access to SIMATIC S7 system compo nents The SIMATIC S7 data can be accessed easily and flexibly The following services are available with S7 communica tion Administrative services e Link management e Mini datab
57. of slave interface input data output data 244 bytes each diagnostics data No of parallel FDL tasks to be processed max 120 No of PG OP and S7 connections max 501 No of FMS connections max 402 1 for credit 1 PDU size lt 480 bytes 2 for credit 1 Ordering data Order No Communication processor 6GK1 561 4AA00 CP 5614 PCI card with master and slave connection to PROFIBUS incl Windows NT 4 0 2000 Pro drivers DP RAM Interface for DP master and slave PG and FDL configuration software with electronic manual on CD ROM Development Kit DK 5613 Software Development Kit for CP 5613 CP 5614 for integration in any operating system environments on systems with PCI slot 1 Download from Internet under http www ad siemens de net dk5613 ec ibilities for PG PC JadzJz Ordering data Order No DP 5613 Windows NT 4 0 gt 6GK1 713 5DB21 3AA0 2000 Pro Software V2 1 for DP protocol on CP 5613 CP 5614 CP 5613 FO CP 5614 FO incl PG FDL and DP OPC server with electronic manual on CD ROM German English S7 5613 Windows NT 4 0 2000 Pro Software V2 1 for S7 communication on CP 5613 CP5614 CP 5613 FO CP 5614 FO incl PG FDL and S7 OPC server with electronic manual on CD ROM German English FMS 5613 Windows NT 4 0 2000 Pro Software V2 1 for FMS protocol on CP 5613 CP5614 CP 5613 FO CP 5614 FO incl PG FDL and FMS OPC server
58. place with the enclosed COM PROFIBUS PC Edition aal Siemens IKPI October 2000 MIPIT O o DI T Functions continued Connection possibilities for PG PC CP 5614 FO communication processor Software for PG OP communication This software enables programming of the SIMATIC S5 S7 controllers via PROFIBUS in connection with STEP 5 STEP 7 The PG OP communication for the CP 5614 FO is already available after installing the CP 5614 FO DP Base No additional software package is needed 5 compatible communica tion SEND RECEIVE based on the FDL interface SEND RECEIVE FDL inter face is already available after installation of the CP 5614 FO DP Base and offers data exchange services for diag nostics and management No additional software pack age is needed Software for S7 communication S7 5613 The user interface is compati ble with S7 5412 SIMATIC S7 system compo nents communicate with each other via S7 communication The S7 programming inter face enables PG PC applica tion programs access to SIMATIC S7 system compo nents The SIMATIC S7 data can be accessed easily and flexibly The following services are available with S7 communica tion Administrative services Link management e Mini database Trace Data transfer services Reading writing of variables BSEND BRECEIVE up to 64 Kbytes per task EEEE KIRII Siemens IK PI October 2000 Soft
59. protocol You can for example prevent variables calculated internally by the controller from being overwritten As default no access protection is activated VFD VFD Virtual Field Device is the neutral description of a device used in FMS Communication connections FMS connections are then configured for the VFDs Here you inform the OPC server of the required VFDs During configuration you then assign the VFD to the FMS connection When accessing variables in the PC application you also reference the VFD Extra function creating the object dictionary Here you can also create the object dictionary OD belonging to a VFD The FMS variables name and structure are defined in the object dictionary Connec tion parameters Here you can make the settings required for communication for services that do not require specific connection configuration Segmenta tion Special settings for providing the data buffers independent of specific connections 42 Please note that the parameters are described in detail in the online help for each individual dialog in NCM PC SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C 156 01 Configuring the OPC Server 3 3 Configuring Connection Properties for the OPC Server When using OPC communication connections are established and managed by the OPC Server As a result you create the communication connections only
60. run through all the previously undetected modules confirm the settings you made for the modules 3 If you want to configure communication on the PC station you can now start the PC Station Wizard When you have finished configuring you return to the Commissioning Wizard 4 If you intend to use the OPC server you can decide whether to create a symbol file or use an existing one in the next step 5 After this the configuration is finally adopted and the PC is ready for the next steps SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 31 Configuring SIMATIC PC Stations 2 6 PC Station Wizard The PC Station Wizard supports you when you create projects in SIMATIC NCM PC It allows you to acquire the configure data of the PC station automatically This helps you to make sure that your configuration data is consistent Tips e Refer to the examples in the Quick Start section Chapters 4 and 5 e We have already described the interaction of the tools and utilities in Section 2 2 Station Configuration How to Start the PC Station Wizard e From the Commissioning Wizard After you have finished configuring the modules you start the wizard by clicking the corresponding button see Section 2 5 and the Quick Start chapters e From the Start menu Select Start gt SIMATIC gt SIMATIC NCM PC Station Wizard SIMATIC NCH PC Station Wizard SIMATIC NET NCM PC Manual Quick Start 32 C79000 G8976 C 1
61. slot under Windows NT 4 0 and Windows 2000 Short PCI card 9 pin Sub D socket for connecting to PROFIBUS Diagnostic LEDs e Parallel operation of max 4 CPs 1 The module is installed using PCI standard mechanisms plug amp play 1 FMS 5613 supports a maximum 2 CP 5613 5614 e PCI card with microproces sor for system interfacing for PCs and SIMATIC program ming devices PC to PROFIBUS up to 12 Mbit s Communication services PROFIBUS DP master according to IEC 61 158 EN 50170 PG OP communication with STEP 5 and STEP 7 S7 communication 5 compatible communi cation SEND RECEIVE on the basis of the FDL interface PROFIBUS FMS according to IEC 61 158 EN 50170 The CP 5613 provides high performance support for con trol tasks on the PC e g PC based control numeric con trol robot control It is connected to the electri cal PROFIBUS through Bus connector and PROFIBUS bus cable or e Bus terminal e g 12M bus terminal and PROFIBUS bus cable It is connected to the optical PROFIBUS through e Bus cable with 2 bus con nectors or 830 1T PROFIBUS connecting cable to an OLM papas e Extensive diagnostic facili ties for installation commis sioning and operation of the module High performance through direct dual port RAM access e Event and filter mechanism for relieving the host CPU e OPC servers are supplied with the com
62. the SEND RECEIVE programming interface You can configure the following communications services depending on the module inserted S7 connections FMS connections PROFIBUS DP services DPVO and DPV1 Note how these differ from the user programs that use the communication service as OPC clients via an OPC Server as described below SIMATIC NET NCM PC Manual Quick Start 22 C79000 G8976 C 156 01 Configuring SIMATIC PC Stations OPC Server You use the convenient interface to an OPC server to communicate with a programmable controller such as a SIMATIC S7 400 The OPC server can be set up as an interface for all available communications protocols You can only create this object once in a PC station You can then use this OPC Server for communication with any number of user programs OPC clients The following communications services can be used depending on the modules inserted all types of connection DP services e CP Industrial Ethernet This contains all the CP modules for attachment to Industrial Ethernet e CP PROFIBUS This contains all the CP modules for attachment to PROFIBUS SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 23 Configuring SIMATIC PC Stations 2 3 4 Creating a DP Master System Read the information below if you want to use a PROFIBUS CP and configure a DP master system Significance of the Configuration Data in a DP Master System The confi
63. the SIMATIC S7 400H to applications on the PC e g WinCC are necessary for assembling a SIMATIC H system with PC connection Typically a redundant Indus trial Ethernet is used The soft ware package can also be used where SIMATIC H sys tems are operated on non redundant networks up to two CP 1613 and S7 REDCONNECT for con necting the PC to Industrial Ethernet with ISO protocol under Windows NT 4 0 Mixed operation of redundant and non redundant systems is also possible CP 443 1 for connecting the S7 400H to Industrial Ethernet with ISO protocol STEP 7 from V5 0 upwards for configuring Application The highly available S7 com Fault detection switching The application e g Win CC munication is fed via a master over if required communica communicates with the 2 sub and a reserve connection tion monitoring and synchroni units of the S7 400H in the concealed for the application zation are handled in the same way as with an S7 CPU which is monitored during background invisible to the operation and switched over application in the event of a fault Functions S7 REDCONNECT contains User interfaces Programming interface the functional scope of the S7 1613 software package S7 communication S5 com patible communication and PG OP communication as well as additional redundant communication via S7 con nections An additional li cence for S7 1613 is unnecessary 5 compatible communica
64. to be processed max 32 100 Software V5 3 for DP protocol No of PG OP and incl FDL protocol and DP OPC server with electronic manual S7 connections max 8 8 on CD ROM S7 communication SOFTNET S7 Windows 98 gt 6GK1 704 5CW53 3AA0 NT 4 0 2000 Pro Software V5 3 for S7 communication incl FDL protocol and S7 OPC server with electronic manual on CD ROM SOFTNET DP slave Windows 98 6GK1 704 5SW12 3AA0 NT 4 0 2000 Pro Software V1 2 for DP slave interface with electronic manual on CD ROM Manual CP 5613 CP 5614 and SOFTNET for PROFIBUS Including Description of the interfaces FMS DP S7 FDL OPC server configuration tools German gt 6GK1 971 5DA00 0AA0 e English gt 6GK1 971 5DA00 0AA1 SIMATIC NET gt 6GK1 704 0AA00 3AA2 Software Update Service For Industrial Ethernet PROFIBUS OPC server including manuals on CD ROM German English Electronic manuals gt 6GK1 975 1AA00 3AA0 Communication systems protocols products on CD ROM German English 3 305 Siemens IK PI October 2000 U a fT System interfacing for PG PC eC ey SIMATIC SIMATIC You can find software for the PC products under Windows on the SIMATIC NET Windows CD including the appropriate manuals in pdf format and extensive further information about SIMATIC NET products and communication The necessary configuring tools are supplied with all software packages Fig 4 53 System interfacing for
65. to the CP PC station from STEP 7 Version 5 1 Service Pack 2 or higher SIMATIC NET PC Software CD 07 2001 79220 A5822 X 01 7419 97 SIMATIC NET PC Software CD 07 2001 SOFTNET DP slave up to version 1 2 for Windows 2000 Pro Windows NT 4 0 or Windows 98 Situation Windows 98 is no longer supported Steps to take Under Windows 98 use the SIMATIC NET CD 05 2000 SOFTNET S7 up to version 5 3 for Windows 2000 Pro Windows NT 4 0 or Windows 98 98 Situation Windows 98 is no longer supported An S7 configuration created with the COML S7 program cannot be used Steps to take Under Windows 98 use the SIMATIC NET CD 05 2000 A configuration created with the COML S7 program must be recreated with SIMATIC NCM PC V5 1 Service Pack 2 or STEP 7 Version 5 1 Service Pack 2 or higher If the configuration was already created with STEP 7 XDB this STEP 7 project can continue to be used You only need to download the configuration to the CP PC station from STEP 7 Version 5 1 Service Pack 2 or higher SIMATIC NET PC Software CD 07 2001 79220 A5822 X 01 7419 SIEMENS Configuring PC Stations with SIMATIC NCM PC Manual and Quick Start for SIMATIC NCM PC STEP 7 V5 1 SP2 and higher al 06 2001 C79000 G8976 C156 Release 01 Preface Contents Manual Introduction and Notes on Switching to Advanced PC Configuration Configuring SIMATIC PC Stations Configuring the OPC Server Quick Start
66. use of the FMS protocol ensures open communication The following services are available via the FMS inter face Administrative services CRL management services FMS connection manage ment services Object directory manage ment services for clients and server Variable services for clients and server read write infor mation report e Server functionality VFD virtual field device services for clients and server Bus access information ser vices live list Trace and mini database Teorey User interfaces OPC interface The OPC server contained in the respective software pack age can be used as a stan dard programming interface for the protocols PROFIBUS DP S7 communication and PROFIBUS FMS to connect automation applications to OPC capable Windows appli cations Office HMI systems etc Programming interface via C Library The programming interfaces for existing applications are implemented as a Dynamic Link Library DLL The follow ing compilers can therefore be used in conjunction with the SIMATIC NET products e Microsoft Visual C C V6 0 e Microsoft Visual Basic V6 0 For Borland programming interfaces e g DELPHI part ner solutions of AIXO are available For solutions for other operat ing systems see the Develop ment Kit DK 5613 The DK 5613 can be found in nternet http www ad siemens de net dk5613 Configuration For all packa
67. use via the Automation Interface VB or OCX Data Control S7 and FMS OPC server only which is supplied e Grouping of variables items whereby a large number of data can be processed in a short time m Functions Open standardization of ad Efficient data exchange from e Several clients can run on dressing using logical names for objects of an automation component or system Support of symbols from STEP 7 3 278 Siemens IK PI October 2000 ey p po a process component to a further processing applica tion e Simultaneous use of several servers by one client appli cation one OPC server at the same time e Server specific configura tion support Connection possibilities for PG PC AAOL y Functions Interfaces Automation Interface for OCX Data Control for continued Custom Interface for easy to create Visual Ba embedding directly in high performance C sic or similar applications COM DCOM compatible applications Windows applications S7 OPC server and FMS OPC server only ApplicationX gt se Application Y WinCC a S Application X DA a OPC Client OPC Client i a il I i j i 7 o d 4 4 FMS OPC S7 OPC XY OPC DP OPC Server A Server B Server C Server Server Server We iy eS el eee a ee 2 Fig 3 106 Comparison of conventional client server architecture with an OPC architecture Configu
68. using standard PCI mechanisms Plug amp Play PROFIBUS with integrated interface through e Plastic and PCF FOCs with simplex plugs It is connected to the electri cal PROFIBUS through Plastic and PCF fiber optic cable with simplex plugs to an OBT Functions PROFIBUS DP Event filter mechanism The new event filter mecha Access to process data with DP Base The CP 5613 FO is operated as a PROFIBUS DP master module which holds the pro cess image input output and diagnostic data in the dual port RAM memory area on the CP The high perfor mance data exchange with the PROFIBUS slaves is han dled independently by the CP 5613 FO hardware The user has direct access to the dual port RAM The process data of the slaves are always consistent i e the user gets the data from one and the same DP cycle Parallel operation of DP Base and DP 5613 software is not possible The user receives up to date data through two access mechanisms e Cyclic polling of the DP slaves higher load on host CPU Signaling by new kind of event filter mode in the event of changes in the input data of a slave minimum load on host CPU Both alternatives can be com bined Optimum utilization of the PC is therefore possible for the relevant application nism can also be used for Signaling by interrupt for di agnostic messages from slaves In equidistant mode signal ing by interrupt Start DP cyc
69. vides the PC programmer with function calls for data transfer In addition the DP interface offers the functions SYNC and FREEZE as well as the activa tion and deactivation of slaves The DP functional expansions with respect to master class 1 enable non cyclic read and write functions DS_READ DS_WRITE as well as alarm acknowledgement ALARM_ACK to be per formed parallel to cyclic data traffic The non cyclic trans mitted data e g parameter ization data are changed very rarely in comparison with the cyclic measured values and are transmitted with low priority parallel to the fast cyclic useful data transfer Interrupt acknowledgment in the master ensures reliable transfer of the interrupts from DP slaves DS_READ DS_WRITE DS_DATA_TRANSPORT Parallel operation of DP Base and DP 5613 software is not possible DP master class 2 In addition to DP master class 1 services the CP 5614 also offers DP master class 2 ser vices in connection with the DP programming interface according to IEC 61 158 EN 50170 Devices of this type programming configu ration or operating devices are used for commissioning configuring the DP system or system operation in normal operation diagnostics The DP programming inter face provides the following services Master diagnostics Slave diagnostics Read inputs outputs of a slave Reading configuration data and Changing the slave address
70. 13 FO CP 5614 FO with electronic manual on CD ROM in German English FMS 5613 Windows V6 0 gt Software for FMS protocol incl PG OP communication FDL FMS OPC server NCM PC under Windows NT 4 0 WS server Windows 2000 Pro server for CP 5613 CP 5614 CP 5613 FO CP 5614 FO with electronic manual on CD ROM in German English Manual CP 5613 CP 5614 and SOFTNET for PROFIBUS Paper version Including Description of the interfaces FMS DP S7 FDL OPC server configuration tools e German e English PROFIBUS FastConnect gt RS 485 bus connector Plug 180 With 180 cable outlet PROFIBUS 12M bus terminal gt Bus terminal for connecting PROFIBUS stations up to 12 Mbit s with connecting cable SIMATIC NET gt Software Update Service For Industrial Ethernet PROFIBUS OPC server including manuals on CD ROM German English SIMATIC NET Manual Collection gt Electronic manuals for communication systems protocols products on CD ROM German English vy 6GK1 713 5DB60 3AA0 6GK1 713 5CB60 3AA0 6GK1 713 5FB60 3AA0 6GK1 971 5DA00 0AA0 6GK1 971 5DA00 0AA1 6GK1 500 0FC00 6GK1 500 0AA10 6GK1 704 0AA00 3AA2 6GK1 975 1AA00 3AA0 Connection options for CP 5613 FO communications processor BE 7 Overview PG PC PCI card with microproces sor for system interfacing for PCs and SIMATIC PGs PC to the optical PROFIBUS with integrated interface up to 12
71. 1613 gt 6GK1 716 0HB13 3AA4 Windows NT 4 0 Upgrade V1 3 Expansion of S7 1613 Windows NT 4 0 to S7 REDCONNECT Windows NT 4 0 on CD ROM German English Manual CP 1613 for Industrial Ethernet Hardcopy contains a description of the interfaces S7 TF S5 compatible communica tion OPC server configuring tool for CP 1613 e German gt 6GK1 971 1GA00 0AA0 e English gt 6GK1 971 1GA00 0AA1 Electronic Manuals gt 6GK1 975 1AA00 3AA0 Communications systems protocols products on CD ROM German English SIMATIC NET gt 6GK1 704 0AA00 3AA2 Software Update Service for Industrial Ethernet PROFIBUS OPC server including manuals on CD ROM German English EEES A Siemens IK PI October 2000 O Industrial Ethernet System interfacing for PG PC S7 REDCONNECT Overview 8s PC with S7 REDCONNECT and 2x CP 1613 G_IK10_del004 Industrial Ethernet Industrial Ethernet D Industrial e For connection of PCs for redundant Industrial Ethernet to SIMATIC S7 400H For redundantly structured Industrial Ethernet Operation is also possible in non redundant networks Completely integrated in STEP 7 from V5 0 OPC servers are supplied with the communications ST MO Ei aL ALLL anh Fig 4 59 System configuration S7 REDCONNECT Application E Design The following components PC with S7 400H with The software package S7 REDCONNECT connects
72. 4 0 Windows 98 from V4 02 and K4 02 5 Drivers for the CP 5611 are included in the scope of supply of STEP 7 SOFTNET S7 The S7 programming inter face can be used with this package SOFTNET DP With this the CP 5611 can be used as a PROFIBUS DP master class 1 or 2 SOFTNET DP slave For using the CP 5611 asa PROFIBUS DP slave E Functions The CP 5611 is operated The following software pack COM PROFIBUS as of V3 3 The CP 5611 can be used with this package for com missioning or diagnostics DP online functions for PROFIBUS DP systems STEP 7 Micro Win as of V2 1 Hardware base for the pro gramming software of the SIMATIC S7 200 program mable controller ProTool ProTool PRO The CP 5611 can be used as the hardware basis for the configuration tool for SIMATIC operator panels touch panels and text dis plays EERE Siemens IK PI October 2000 WIKUIT p pe am 5 f Designed for Industry Technical specifications Data transfer rate Interfaces e Connection to PROFIBUS Supply voltage Current consumption Power loss Perm ambient conditions Operating temperature Transport storage temperature e Relative humidity max Design e Module format Dimensions H x D in mm e Weight approx e Space required PNanhARntTtAK AAA Connection poss Connection for portable PCs to PROFIBUS e g for diag nostics and commissioning 9 6 Kbit s to 12 Mbit s 9
73. 47 Quick Start for the OPC Application for PROFIBUS DP 4 2 Quick Start for PROFIBUS Communication with OPC Introduction This example illustrates how you can connect an ET 200 B DP slave with a CP 5613 in a PC station over PROFIBUS DP This section describes the programs used for configuring a PC station and a DP slave You will also see how to use the OPC Scout program for communication with the OPC Server Requirements If you want to try out the example yourself you require the following e aPC e acommunication module for PROFIBUS CP 5613 e the SIMATIC NET CD 07 2001 software e an ET 200 B DP slave e PROFIBUS cabling between the PC module and ET 200 device SIMATIC NET NCM PC Manual Quick Start 48 C79000 G8976 C156 01 Quick Start for the OPC Application for PROFIBUS DP 4 2 1 Hardware and Software Installation Installing the Software Activity Turn on the PC and start Windows Insert the SIMATIC NET 07 2001 CD If the installation program does not start the CD automatically start the Setup exe program on the CD Follow the on screen instructions of the installation program Install the SIMATIC NET software and SIMATIC NCM PC Installing the CP 5613 Activity Shut down the PC and turn it off Disconnect the power cable Read the instructions for installing cards in the manufacturer s instructions for your PC Insert the CP 5613 module in a PCI slot Reassemble the PC
74. 56 01 Configuring SIMATIC PC Stations The PC Station Wizard supports you in the following situations Changing local settings If the SIMATIC NCM PC configuration tool is installed on the destination PC station the wizard can compare the configuration data with the planned configuration data that already exist The communications parameters can then be edited in the project directly Editing a saved configuration Open an existing project and compare the local configuration with the information in the project In contrast to the Change Local Settings function the configuration edited here is independent of an existing local configuration Creating a new configuration Create a new project and enter the local configuration in the project Starting the Station Configuration Editor When working offline this option make use of an XDB file configuration station and PC station are not connected see Section 2 2 SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 33 Configuring SIMATIC PC Stations 2 7 Station Configuration Editor Purpose The Station Configuration Editor is the central management entity for the components of the PC station Components are the modules and communications tasks of active applications The Station Configuration Editor can also be used for diagnostic purposes Modes You can use the Station Configuration Editor for the local PC station or for a PC accessible over the ne
75. 5614 FO can be integrated in any operating system environments The kit contains the necessary source code including the descriptions in PDF format and can be downloaded from the Internet Access to process data with DP 5613 The user interface is compati ble with software package DP 5412 DP master class 1 The CP 5613 FO operates as a DP master class 1 and han dles data transfer with the dis tributed stations DP slaves completely independently In a fixed repetitive message cycle the central controller exchanges information with the DP slaves e g ET 200S The DP programming inter face DPLib DLL provides the PC programmer with function calls for data transfer In addi tion the DP interface offers the functions SYNC and FREEZE as well as the activa tion and deactivation of slaves The DP functional expansions with respect to master class 1 enable non cyclic read and write functions DS_READ DS_WRITE as well as alarm acknowledgement ALARM_ACkK to be per formed parallel to cyclic data traffic The non cyclic trans mitted data e g parameter ization data are changed very rarely in comparison with the cyclic measured values and are transmitted with low priority parallel to the fast cyclic useful data transfer Interrupt acknowledgment in the master ensures reliable transfer of the interrupts from DP slaves DS_READ DS_WRITE DS_DATA_TRANSPORT Parallel operation of DP Base and DP 5613
76. 61 4FA00 H Ordering data Order No DP 5613 Windows V6 0 gt Software for DP protocol incl PG OP communication FDL DP OPC server NCM PC under Windows NT 4 0 WS server Windows 2000 Pro server for CP 5613 CP 5614 CP 5613 FO CP 5614 FO with electronic manual on CD ROM in German English S7 5613 Windows V6 0 gt Software for S7 communication incl PG OP communication FDL S7 OPC server NCM PC under Windows NT 4 0 WS server Windows 2000 Pro server for CP 5613 CP 5614 CP 5613 FO CP 5614 FO with electronic manual on CD ROM in German English FMS 5613 Windows V6 0 gt Software for FMS protocol incl PG OP communication FDL FMS OPC server NCM PC under Windows NT 4 0 WS server Windows 2000 Pro server for CP 5613 CP 5614 CP 5613 FO CP 5614 FO with electronic manual on CD ROM in German English PROFIBUS FastConnect gt RS 485 bus connector Plug 180 PROFIBUS 12M bus terminal gt PROFIBUS plastic fiber optic simplex plug polishing set PROFIBUS plastic fiber optic stripping tool set Connection adapters e 50 pcs Manual CP 5613 CP 5614 and SOFTNET for PROFIBUS Paper version Including Description of the interfaces FMS DP S7 FDL OPC server configuration tools German gt English gt SIMATIC NET gt Software Update Service For Industrial Ethernet PROFIBUS OPC server including manuals on CD ROM German English SIMATIC NET Manual Collection
77. 6GK1 704 1CW33 3AA0 SOFTNET PG Windows 98 gt 6GK1 704 1PW33 3AA0 NT 4 0 2000 Pro for Industrial Ethernet German English SIMATIC NET gt 6GK1 704 0AA00 3AA2 Software Update Service for Industrial Ethernet PROFIBUS OPC server including manuals on CD ROM German English CP 1613 and SOFTNET Manual for Industrial Ethernet Hardcopy German gt 6GK1 971 1GA00 0AA0 English gt 6GK1 971 1GA00 0AA1 Electronic Manuals gt 6GK1 975 1AA00 3AA0 Communications systems protocols products on CD ROM German English Industrial Ethernet System interfacing for PG PC SOFTNET for Industrial Ethernet D Industrial Overview EOUN DRT ON Application CP 1411 PC PG SOFTNET for Industrial Ethernet CP 1511 an D lt orn a J d A Industrial Ethernet S5 115U to 155U with CP 1430 TF al 343 1 7 400 it CP 443 1 gl G 0_del0040s Fig 4 62 SOFTNET for Industrial Ethernet system configuration With SOFTNET for Industrial Ethernet programming devices PCs workstations can be connected to PLCs e g SIMATIC S7 via Industrial Ethernet The following appli cation interfaces are avail able PG OP communication for SIMATIC S7 5 compatible communica tion SEND RECEIVE for communication with SIMATIC S7 S7 communication For connecting program ming devices PCs workstations with automa tion systems Communicati
78. A 5 By Poe ajm anj d Hardware Catalog x Standard PROFIBUS DP Additional Field Devices Closed Loop Controller E Configured Stations __PROFIBUS 1 DP master 1 B 16D0 2 Slot Module _ Ordernumber__ Address_ QAddress_ SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 25 Configuring SIMATIC PC Stations 2 3 5 Configuring Connections Meaning During operation configured connections are established either implicitly or on request depending on the parameter assignment They are then available to the OPC Server or the PC application for communication General Rules Regardless of the type of application these general rules apply when configuring connections e Communication connections are always assigned to an application e Inthe PC station the CP that supports the type of connection is used for the data transfer e f there is more than one CP with this capability you can use Routing to select the transmission path Follow the steps below 1 Select the application to which you want to assign a connection iz NetPro PC Station_1 Network C Siemens Step7 5 7proj PC_Sta_2 92 Network Edit Insert PLC View Options Window Help S So elel lil S 58 BD Rel Ethernet 1 Industrial Ethernet MPI 1 MPI PROFIBUS 1 PROFIBUS 57 connection_1 S connection_1 SIMATIC PC Stati S connection 7 connection _2 57 connection_2 SIMATIC PC Stat
79. ATIC NCM PC is the central tool for configuring the communications services for your PC station After creating your configuration data with this tool you then download it to the PC station The PC station is then ready for communication Note You can configure both in SIMATIC NCM PC and in STEP 7 STEP 7 also provides all the SIMATIC NCM PC functions described here for configuring your PC From now on the description will only refer to SIMATIC NCM PC but nevertheless applies to both Station Manager with the Station Configuration Editor With the Station Configuration Editor you can both display and edit the list in which the components are managed in the Station Manager on a PC station The Station Configuration Editor also provides diagnostic services SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 11 Configuring SIMATIC PC Stations Wizards Mean Less Work The following wizards can be used in most situations e Commissioning Wizard A Commissioning Wizard helps you to integrate a newly installed communications module in a few simple steps so that subsequent configuration with the PC Station Wizard and the SIMATIC NCM PC configuration tool is normally extremely simple The existing configuration of the PC can be queried automatically you do not need to call up the Station Configuration Editor explicitly e PC Station Wizard The PC Station Wizard helps you when creating and handling projects for
80. C NET are registered trademarks of SIEMENS AG Third parties using for their own purposes any other names in this document which refer to trademarks might infringe upon the rights of the trademark owners SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C 156 01 Safety Instructions Regarding your Product Before you use the product described here read the safety instructions below thoroughly Qualified Personnel Only qualified personnel should be allowed to install and work on this equipment Qualified persons are defined as persons who are authorized to commission to ground and to tag circuits equipment and sy stems in accordance with established safety practices and standards Correct Usage of Hardware Products Warning Note the following This device and its components may only be used for the applications described in the catalog or the technical description and only in connection with devices or components from other manufacturers which have been approved or recommended by Siemens This product can only function correctly and safely if it is transported stored set up and installed correctly and operated and maintained as recommended Before you use the supplied sample programs or programs you have written yourself make certain that no injury to persons nor damage to equipment can result in your plant or process EU Directive Do not start up until you have established that the machine on whi
81. C NET product CD lt CD drive gt gt sw gt cdintern gt hinw_e rtf Consequences The following sections explain the effects of switching to Advanced PC Configuration You should also read the chapter Installation and Commissioning in the HTML document Industrial Communication for PG PC supplied on the CD SIMATIC NET PC Software CD 07 2001 S79220 A5822 X 01 7419 87 SIMATIC NET PC Software CD 07 2001 4 2 LDB and XDB Databases 4 2 1 Introduction Consequences of the New Central Configuration As of the SIMATIC NET PC software CD 07 2001 all SIMATIC NET PC software products have central configuration and download mechanisms The configuration data are now stored in XDB databases The previously used LDB databases can no longer be used Existing XDB databases can continue to be used after importing them into the central data management of the PC station the Station Configuration Editor Using the Databases and Central Data Management The graphics on the following pages illustrate the new situation e Configurations in previous product versions and the use of databases e New totally integrated and uniform configuration with the Station Configuration Editor e New totally integrated and uniform configuration within Advanced PC Configuration with SIMATIC NCM PC V5 1 Service Pack 2 STEP 7 Version 5 1 Service Pack 2 or higher The local or remote configuration data are downloaded using SIMATIC NCM PC STEP 7
82. CI slot 10 100 Mbit s for 10Mbits Triaxial network Bus connector Transceiver Bus cable 727 0 triaxial cable e m oe up to 500 m Twisted Pair Network Sub D OSM ESM OLM ELM ITP Standard Cable e upto 100m 10 100 Mbits Twisted Pair Network RU45 Structured cabling acc to EN 50173 Twisted Pair Switch e g ESM TP80 FC Outlet RJ45 FC Outlet RU45 G_IK10_del0051s Fig 4 58 Mains connection possibilities CP 1613 EE Siemens IKPI October 2000 MAET ll Industrial Ethernet system interfacing for PG PC CP 1613 communication processor Industrial E Design The CP 1613 module Connections The module is connected card with microprocessor 15 pin Sub D socket for use forexample is plugged directly into a in industrial applications for electrical networks via a SIMATIC PG PC or a PC and automatic switching be 727 1 connecting cable bus requires asnon Ee Tone tween AUI ITP and RJ45 coupler to the 727 0 bus interface for ITP via the ITP standard RJ45 for connection in the cable 9 15 to OSM ESM office environment star coupler for optical networks via the Mini OTDE optical transceiver H Application The module independently The data exchange between The data transfer between the processes the protocols up to module and host takes place host system and the CP 1613 and including level 4 trans in master mode This means is handled by a Windows NT port
83. CP 5613 communications gt 6GK1 561 3AA00 processor PCI card for connection to PROFIBUS incl Windows NT 4 0 WS server Windows 2000 Pro server driver DPRAM Interface for DP master incl PG and FDL configuration software with electronic manual on CD ROM Development kit DK 5613 Software development kit for CP 5613 CP 5614 CP 5613 FO CP 5614 FO for integration in any oper ating system environments on systems with PCI slot Download from Internet at http www siemens de simatic net dk5613 3 344 Siemens IK PI 2001 Higher computing perfor mance in the PC by relieving the host CPU Fast commissioning through Plug amp Play and diagnostic tools Implementation for motion control applications possi ble through support of the equidistant mode Easy portability to other op erating systems through a dual port RAM interface Can also be used in high temperature industrial environments E Ordering data Order No DP 5613 Windows V6 0 gt Software for DP protocol incl PG OP communication FDL DP OPC server NCM PC under Windows NT 4 0 WS server Windows 2000 Pro server for CP 5613 CP 5614 CP 5613 FO CP 5614 FO with electronic manual on CD ROM in German English S7 5613 Windows V6 0 gt Software for S7 communication incl PG OP communication FDL S7 OPC server NCM PC under Windows NT 4 0 WS server Windows 2000 Pro server for CP 5613 CP 5614 CP 56
84. DP PROFIBUS DP master class 2 including acyclic DP expansions with SOFTNET DP PROFIBUS DP slave with SOFTNET DP slave PG OP communication 7 communication with SOFTNET S7 5 compatible communi cation SEND RECEIVE based on the FDL inter face with SOFTNET DP or SOFTNET S7 PCMCIA card type II for PG PCs with PCMCIA slot and notebooks Used with STEP 7 ProTool Micro Win ProTool Pro SIMATIC PDM for PG OP communica tion COM PROFIBUS SOFTNET S7 for S7 communication SOFTNET DP for DP OPC servers are supplied with the communication soft ware A pplication The CP 5511 enables connec tion of programming devices and AT compatible PCs to PROFIBUS and to the multi point interface MPI of SIMATIC S7 for connecting PCMCIA slot and notebooks E Design PCMCIA card type II Adapter with 9 pin Sub D socket for connection to PROFIBUS m Functions The CP 5511 is operated The following software pack COM PROFIBUS as of V3 3 under different software pack ages and allows the user to execute programming device functions and PC functions via PROFIBUS and the multipoint interface MPI Only one CP can be operated for each PG PC notebook Similarly only one protocol PROFIBUS DP S7 communi cation or FDL can be used for each CP ages support the CP 5511 STEP 7 as of V3 2 Drivers for the CP 5511 are supplied with ST
85. EP 7 SOFTNET S7 The S7 programming inter face can be used with this package SOFTNET DP With this the CP 5511 can be used as a PROFIBUS DP master class 1 or 2 SOFTNET DP slave for using the CP 5511 asa PROFIBUS DP slave With this package the CP 5511 can be used for commissioning or diagnos tics DP online functions for PROFIBUS DP systems STEP 7 Micro Win as of V2 1 Hardware base for the pro gramming software of the SIMATIC S7 200 program mable controller ProTool ProTool PRO The CP 5511 can be used as the hardware basis for the configuration tool for SIMATIC operator panels touch panels and text dis plays as Siemens IKPI October 2000 WIPEEE e Connection for notebooks or other portable PCs to PROFIBUS e g for diag nostics and commissioning Designed for Industry Easy installation and commissioning Technical specifications B Ordering data Order No Data transfer rate 9 6 Kbit s to 12 Mbit s gt 6GK1 551 1AA00 A 5 f Interfaces e Connection to PROFIBUS Connection to PG PC Supply voltage Current consumption Power loss Perm ambient conditions Operating temperature Transport storage temperature e Relative humidity max Design e Module format e Dimensions W x H x D in mm e Weight without adapter with adapter e Space required approx approx 9 pin Sub D socket PCMCIA slot type II 5 V DC 5 typ 270
86. FMS 5613 Windows from V6 0 on CP5613 CP5614 Software Windows from V6 0 on CP 5511 SOFTNET DP Windows_ from V6 0 on IK PI 2001 SOFTNET S7 Windows from V6 0 on SOFTNET DP Slave Windows from V6 0 on CP 5611 SOFTNET DP Windows_ from V6 0 on IK PI 2001 and integr PB interfaces in SOFTNET S7 Windows from V6 0 on the IPCs PGs gt Prerequisite Np CP 5611 compatible SOFTNET DP Slave Windows from V6 0 on Industrial Ethernet CP 1613 S7 1613 Windows from V6 0 on IK PI 2001 PG 1613 Windows from V6 0 on CP 1512 SOFTNET S7 Windows from V6 0 on IK PI 2001 SOFTNET PG Windows from V6 0 on CP 1612 SOFTNET S7 Windows from V6 0 on IK PI 2001 and integr Ethernet SOFTNET PG Windows from V6 0 on interfaces of the IPCs PGs on preparation More details can be found in description SIMATIC NET PC Software CD 07 2001 chapter 4 3 and chapter 4 4 Siemens AG 2001 All Rights Reserved Technical data subject to change Information on Advanced PC Configuration and SIMATIC NCM PC Release 01 The following components are not supported by Advanced PC Configuration Boards In relation with SIMATIC NET Software Described in catalogue PROFIBUS CP 5613 5613FO DP 5613 Windows up to V2 1 IK PI 2000 CP 5614 5614FO 7 5613 Windows up to V2 1 FMS 5613 Windows up to V2 1 CP5613 CP5614 Software Windows up to V2 1 CP 5511 SOFTNET DP Windows up to V5 3 IK PI 2000 SOFTNET S7 Wi
87. G PC OPC server Industrial WinCC OFC Client Application x baa Application Y Qeeeesn Qeeeeess LI I 2 v a Application X OC Client a bw Damm Server B Server C C 7 OPC XY OPC DP OPC Server Server Server G_IK10_deP0041s Fig 4 57 Comparison of conventional client server architecture with an OPC architecture The communications parame ters can be completely config ured using the tools in the software which is already installed Configuration supply in C A kl e For custom interface The following demo programs are included in the scope of For automation interface with Visual Basic Different networks and pro tocols can be easily imple mented due to the uniform Designed for Industry e Easy integration in the system environment and of fice applications via C e Easy to handle and cost effective because the OPC servers are supplied with the communication software interface and Visual Basic interface Low training and familiariza Applications can be gener tion costs ated quickly E Technical specifications OPC server E Product versions Product S7 1613 Open and standardized e Can be implemented on installa tions from various manufacturers e Groups of variables items Programming e a set of variables TF 1613 therefore a large quantity of data can be processed in a short time
88. HMI systems etc Programming interface through C Library The programming interfaces for existing applications are implemented as a Dynamic Link Library DLL The follow ing compilers can therefore be used in conjunction with the SIMATIC NET products Microsoft Visual C C Version 6 0 e Microsoft Visual Basic Version 6 0 For Borland programming interfaces e g DELPHI partner solutions of AIXO are available Connection options for PaPe DOOR rnc rus a Configuration Configuration of S7 commu The configuring tool NCM PC is a component of nication protocols NCM PC is included in Advanced PC Configuration S5 compatible communica delivery of the PROFIBUS tion DP protocol DP DPV1 software package DPV2 and FMS protocol is executed in STEP 7 NCM PC V5 1 SP2 or higher Designed for Industry e Low cost integration as S7 communication with PROFIBUS DP master class SOFTNET S7 1 or master class 2 with SOFTNET DP As a PROFIBUS DP slave with SOFTNET DP slave enn oes a CC Performance data Single protocol operation Ordering data Order No v CP 5511 CP 5611 DP interface No of connectable DP slaves max 60 60 SOFTNET DP Windows V6 0 gt 6GK1 704 5DW60 3AA0 No of parallel FDL tasks Software for DP protocol to be processed max 32 100 master class 1 and 2 FDL No of PG OP and incl DP OPC server NCM PC under Windows NT 4 0 WS server Windows 2000 Pro server
89. IBUS 9 pin Sub D socket Supply voltage from PCI 5 V DC 5 Power consumption from 5 V 1 3A Power loss 6 5 W Perm ambient conditions Operating temperature without fan with fan air current 0 5 m s Transport storage temperature 5 C to 40 C 5 C to 60 C 40 C to 70 C Relative humidity max 95 at 25 C Design e Module format PCI card Dimensions W x H in mm 107 x 168 e Weight approx 250g e Space required 1 x PCI slot Performance data Single protocol mode Number of connectable DP slaves max 122 No of parallel FDL tasks to be processed max 120 No of PG OP and S7 connections max 501 No of FMS connections max 402 1 for credit 1 PDU size lt 480 bytes 2 for credit 1 Ordering data Order No CP 5613 communication processor gt 6GK1561 3AA00 PCI card for connection to PROFIBUS incl Windows NT 4 0 2000 Pro drivers DP RAM interface for DP master incl PG and FDL configuration software with electronic manual on CD ROM Development Kit DK 5613 Software Development Kit for CP 5613 CP 5614 CP 5613 FO CP 5614 FO for integration in any oper ating system environments on systems with PCI slot Download from Internet under http www ad siemens de net dk5613 3 284 2 Siemens IK PI October 2000 ey p Higher computing perfor mance in the PC by relieving the host CPU e Easy portability to other op
90. IMATIC NET You will find information on the basic aspects of the OPC indicated by the graphic shown below F Ora k Ta 2 Ys ba ne Grundlagen der OPC Schnittstelle SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 39 Configuring the OPC Server 3 1 Significance of Configuration The OPC Server Application Type The OPC Server can be configured as an interface to all available communication protocols You can create this object only once in a PC station You can then use this OPC Server for communication with any number of user programs OPC clients What Can be Configured You can configure the OPC Client following e g operator control and monitoring syste e Protocol and service dependent OPC Server far SIMATIC NET properties Alarms amp Events e Properties for specific connections Protocol software from SIMATIC NET Communications processor from SIMATIC NET Standard Situation Using the default settings In the simplest case in other words the standard situation you simply need to create the OPC Server in the PC station You must also create the communications modules used in the station and configure communication connections The steps are described in detail in Section 2 3 Configuring with SIMATIC NCM PC If you use the PC Station Wizard you will be able to put your PC station into operation both quickly and simply Using default settings or configured parameters Th
91. Information on Advanced PC Configuration and SIMATIC NCM PC Release 01 Information on Advanced PC Configuration and SIMATIC NCM PC Content e History of the document e Supported and not supported boards and software e Advanced PC Configuration Change to the SIMATIC NET PC Software CD 07 2001 Chapter 4 Part of the installation manual SIMATIC NET PC Software CD 07 2001 e Configuring PC Stations with SIMATIC NCM PC Manual and Quick Start e Part of the catalogue IK PI 2001 for PC boards and software e Part of the catalogue IK PI 2000 for PC boards and software Siemens AG 2001 All Rights Reserved Technical data subject to change Information on Advanced PC Configuration and SIMATIC NCM PC Release 01 History of the document Release Dated Changes compared to the previous release 01 07 2001 First release of this information collection on the items Advanced PC Configuration and NCM PC Siemens AG 2001 All Rights Reserved Technical data subject to change Information on Advanced PC Configuration and SIMATIC NCM PC Release 01 Supported and not supported boards and software The following components are supported by Advanced PC Configuration Boards In relation with SIMATIC NET Software Described in catalogue PROFIBUS CP 5613 5613FO DP 5613 Windows from V6 0 on IK PI 2001 CP 5614 5614FO 7 5613 Windows from V6 0 on
92. NCM PC Siemens IK PI 2001 3 359 O b 3 Designed for Industry Technical specifications Data transfer rate Interfaces e Connection to PROFIBUS Connection to PG PC Supply voltage Current consumption Power loss Perm ambient conditions e Operating temperature Transport storage temperature e Relative humidity Design e Module format Dimensions W x H x D in mm e Weight without adapter with adapter e Space required 3 360 Siemens IK PI 2001 i ij approx approx Connection options for CP 5511 communications processor Connection for notebooks or other portable PCs to PROFIBUS e g for diag nostics and commissioning 9 6 kbit s to 12 Mbit s 9 pin Sub D socket PCMCIA slot type II 5 V DC 5 typ 270 mA max 360 mA 1 8W 5 C to 40 C 20 C to 60 C 95 at 25 C PCMCIA type II 54 x 85x 5 30g 130 g 1 x PCMCIA slot type II e Easy installation and com missioning Ordering data Order No CP 5511 communications processor PCMCIA card for connecting a PG or PC to PROFIBUS or MPI SOFTNET S7 Windows V6 0 Software for S7 communication incl FDL S7 OPC server NCM PC under Windows NT 4 0 WS server Windows 2000 Pro server for CP 5511 and CP 5611 with electronic manual on CD ROM SOFTNET DP Windows V6 0 Software for DP protocol master class 1 and 2 FDL incl DP OPC server NCM PC under Windows
93. ND RECEIVE P lug amp Play OPC servers are supplied with the communication software Application The CP 1411 is an Ethernet It is intended for applications The CP 1411 can be operated card which can be operated in an industrial environment with all SOFTNET for Indus in any programming trial Ethernet packages device PC with a free ISA slot Design 15 pin Sub D socket for use With a special controller the There is no need to set jump in industrial applications CP 1411 is able to support the ers The configuration is made automatic switching be plug amp play mechanism of the by software The settings are tween AUI or industrial twist operating system resident on the module Free ed pair assignment of the Ethernet RJ45 interface for connec a ee USELIO tion in the office environment make rapid and simple changes for startup or diag nostics E Application The CP 1411 offers the follow Level 4 and level 7 In addition the protocols for ing accesses In conjunction with SOFTNET Industrial Ethernet provided Layer 2 packages for Industrial by the operating system are Interfacing for PC networks Ethernet the CP 1411 offers also supported in an industrial environment 0w costaccessto Industrial The AUI interface under Ethernet e g for SIMATIC Windows 2000 Professional is S5 S7 not supported 4 121 Siemens IK PI October 2000 p O Industrial Ethernet System interfacing for PG PC CP
94. ND RECEIVE based on the FDL interface SOFTNET is available for the following interfaces CP 5511 PCMCIA card e CP 5611 PCI card Integrated PROFIBUS inter faces of SIMATIC program ming devices PCs E Principle of operation SOFTNET processes the com This architecture means that packages depends on the plete protocol stack in the PC unlike CP 5613 or CP 5614 products the performance capability of the SOFTNET construction and or the work load of the PCs used E Functions Software for DP protocol Devices of this type program DP slave SOFTNET DP DP master class 1 SOFTNET DP offers DP master class 1 functions in conjunc tion with the CP 5511 or CP 5611 In a fixed repetitive message cycle the central controller exchanges information with the DP slaves e g ET 200S The DP programming inter face DPLib DLL provides the PC programmer with function calls for data transfer In addi tion the DP interface offers the functions SYNC and FREEZE as well as the activa tion and deactivation of slaves DP master class 2 In addition to DP master class 1 services SOFTNET DP also offers DP master class 2 services ming devices configuration devices or operating devices are used on startup on con figuring the DP system or for operating the system during normal operation e g diag nostics The DP programming inter face provides the following services Master diagnostics sla
95. NT 4 0 WS server Windows 2000 Pro server for CP 5511 and CP 5611 with electronic manual on CD ROM SOFTNET DP Slave Windows V6 0 Software for DP slave incl OPC server under Windows NT 4 0 WS server Windows 2000 Pro server for CP 5511 and CP 5611 with electronic manual on CD ROM PROFIBUS FastConnect RS 485 bus connector Plug 180 With 180 cable outlet Manual CP 5613 CP 5614 and SOFTNET for PROFIBUS Paper version Including Description of the interfaces FMS DP S7 FDL OPC server configuration tools German e English SIMATIC NET Software Update Service For Industrial Ethernet PROFIBUS OPC server including manuals on CD ROM German English SIMATIC NET Manual Collection Electronic manuals for communication systems protocols products on CD ROM German English gt vy 6GK1 551 1AA00 6GK1 704 5CW60 3AA0 6GK1 704 5DW60 3AA0 6GK1 704 5SW60 3AA0 6GK1 500 0FC00 6GK1 971 5DA00 0AA0 6GK1 971 5DA00 0AA1 6GK1 704 0AA00 3AA2 6GK1 975 1AA00 3AA0 Connection options for PG PC CP 5611 communications processor BE The CP 5611 enables the con nection of programming devices and PCs to PROFIBUS and multipoint capable MPI interfaces of the SIMATIC S7 Short PCI card 9 pin Sub D socket for connection to PROFIBUS under different software pack ages and allows the user to execute programming device functions and PC functions through P
96. P cycle Parallel operation of DP Base and DP 5613 software is not possible e PCI card with microproces sor for system interfacing for PCs and SIMATIC program ming devices PC to PROFIBUS up to 12 Mbit s Communication services PROFIBUS DP master according to IEC 61 158 EN 50170 PG OP communication with STEP 5 and STEP 7 7 communication 5 compatible communi cation SEND RECEIVE on the basis of the FDL interface PROFIBUS FMS according to IEC 61 158 EN 50170 performance support for con trol tasks on the PC e g PC based control numeric con trol robot control cal PROFIBUS by bus connector and PROFIBUS bus cable or e bus terminal e g 12M bus terminal and PROFIBUS bus cable It is connected to the optical PROFIBUS by bus cable with 2 bus con nectors or 830 1T PROFIBUS connect ing cable to an OLM The user receives up to date data via two access mechanisms e Cyclic polling of the DP slaves higher load on host CPU e Signalling by new kind of event filter mode in the event of changes in the input data of a slave minimum load on host CPU Both alternatives can be com bined Optimum utilization of the PC is therefore possible for the application in question Extensive diagnostic facili ties for installation commis sioning and operation of the module High performance via direct Dual Port RAM access Event and filter m
97. PG PC ial Ethernet system teo for PG PC Ethernet Industrial Protocol software runs on the CP Free PC resources for applications i Suitable for extensive i applications mee 1g Recommended for M applications with HMI BET J systems with high performance requirements e g WinCC gt Recommended for large scale systems 5 stations and more e g SIMATIC gt Constantly high communication thruput gt Use for redundant communication gt Time synchronization CP 1613 PCI v v v Yy 7 CP 1411 ISA gt Protocol software runs on the PG PC gt PC resources are divided between communication and applications gt Suitable for less extensive J T applications CP 1511 PCMCIA gt Recommended for smaller sytems up to 4 stations e g SIMATIC gt The communication performance depends on PC resources and PC workload G_IK10_ deP0O5Ss Siemens IK PI October 2000 Industrial Ethernet System interfacing for PG PC Industrial Data throughput A comparison between This course fluctuates in Used with software packages Industrial Ethernet CP 1413 CP 1411 CP 1511 CP 1411 and CP 1511 with communication performance CP 1413 predecessor to the appropriate software for the CP 1613 is stable and CP 1613 and CP 1613shows packages between 0 and the high permitting fast response the course of the respective maximum throughput times without fluctuations communication perfor
98. PROFIBUS FMS to connect automation applications to OPC capable Windows appli cations Office HMI systems etc Programming interface via C Library The programming interfaces for existing applications are implemented as a Dynamic Link Library DLL The follow ing compilers can therefore be used in conjunction with the SIMATIC NET products Microsoft Visual C C Version 6 0 e Microsoft Visual Basic Version 6 0 For Borland programming interfaces e g DELPHI part ner solutions of AIXO are available H H T a fap lities TOI eTe TOTE Configuration The necessary configuration The configurations generated Configuration of PROFIBUS tools are supplied with the for the PCs using STEP 7 are DP takes place with the appropriate packages stored in files which are sub enclosed COM PROFIBUS The complete configuration of Sequently transferred to the PC Edition the S7 communication is per Individual PCs formed using STEP 7 V5 0 ServicePack 3 and higher Designed for Industry e Low cost integration as to S7 communication with PROFIBUS DP master of SOFTNET S7 class 1 or master of class 2 with SOFTNET DP as a PROFIBUS DP slave with SOFTNET DP slave a 6 E Performance data Single protocol operation i Ordering data Order No u CP 5511 CP 5611 DP interface Number of connectable DP slaves max 60 60 SOFTNET DP Windows 98 gt 6GK1 704 5DW53 3AA0 No of parallel FDL tasks pia 2000 Pro
99. Quick Start for the OPC Application for PROFIBUS DP 4 2 12 OPC Scout Displaying and Modifying Values of Variables Executing Synchronous and Asynchronous Write Jobs Activity OPC Scout New Project1 I kemhames Value Type Qualiy Time Stamp 01G DP DP_5613 Slave005_E B0 2 010 uint3 goo 04 27 2001 14 28 43 848 DP DP_5613 Slave005_AB0 2 010 uint8 good 04 27 2001 14 28 43 848 Now double click on the Value cell of the output byte with the content 0 0 first table row A dialog opens in which you can change the value of a variable Click the OK button to start the write job SIMATIC NET NCM PC Manual Quick Start 60 C79000 G8976 C 156 01 5 Quick Start for the OPC Application for Industrial Ethernet 5 1 Example of an Industrial Ethernet Configuration How does a communication system with Industrial Ethernet appear Below you will find an example of a communication system using Industrial Ethernet Typical communication partners are attached to Industrial Ethernet and they can be reached over the OPC Server 55 AG 115 PCPG mit CP 1613 OPC Interface 57 300 BN i 37 400 Example of an Industrial Ethernet Configuration Communication takes place between two devices or modules Communication in this sense means the transfer of data between two communication partners with different characteristics controlling the c
100. ROFIBUS and the multipoint interface MPI Only one CP can be operated for each programming device PC Similarly only one protocol PROFIBUS DP S7 communication or FDL can be used for each CP For connecting PG PC to PROFIBUS and MPI of the SIMATIC S7 Communication services PROFIBUS DP master class 1 with SOFTNET DP PROFIBUS DP master Class 2 including acyclic DP expansions with SOFTNET DP PROFIBUS DP slave with SOFTNET DP slave PG OP communication S7 communication with SOFTNET S7 5 compatible communi cation SEND RECEIVE on the basis of the FDL in terface with SOFTNET DP or SOFTNET S7 e For PGs PCs with PCI slot ages support the CP 5611 STEP 7 V3 2 upwards under Windows 95 and NT 4 0 Windows 98 from V4 02 and K4 02 5 Drivers for the CP 5611 are included in delivery of STEP 7 SOFTNET S7 The S7 programming inter face can be used with this package SOFTNET DP With this the CP 5611 can be used as a PROFIBUS DP master class 1 or 2 SOFTNET DP Slave For using the CP 5611 as a PROFIBUS DP slave Jaded J Short PCI card for programming device PC with PCI slot Used with STEP 7 STEP 7 Micro Win SIMATIC NCM PC ProTool ProTool Pro SIMATIC PDM for PG OP communication COM PROFIBUS SOFTNET S7 for S7 communication SOFTNET DP for DP e OPC servers are supplied with the communication soft war
101. SIMATIC NET NCM PC Manual Quick Start 64 C79000 G8976 C 156 01 Quick Start for the OPC Application for Industrial Ethernet 5 2 3 STEP 7 Starting the PC Station Wizard Specifying the Configuration Activity SIMATIC NET Commissioning Wizard Configuration o Here you specify the configuration that will be used for this PC Only click the Next button in the Commissioning Wizard dialog when you have completed the configuration SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 65 Quick Start for the OPC Application for Industrial Ethernet 5 2 4 STEP 7 PC Station Wizard Selecting the Editing Mode Changing Settings Activity SIMATIC NCH PC Station Wizard Click the Next button SIMATIC NET NCM PC Manual Quick Start 66 C79000 G8976 C 156 01 Quick Start for the OPC Application for Industrial Ethernet 5 2 5 STEP 7 PC Station Wizard Opening the Project Creating a Copy of the Local PC Station Activity Select Project Sample_lE C ProgrammeSIEMENS SIMATIC NCM4S 7proj Sam DP_5613_Test c Programme SIEMENS SIMATIC NCM s proj Dp_5 Click the Next button SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 67 Quick Start for the OPC Application for Industrial Ethernet 5 2 6 STEP 7 PC Station Wizard Changing Settings Editing the Network and Connection Confi
102. S_DATA_TRANSPORT Parallel operation of DP Base and DP 5613 software is not possible e DP master class 2 In addition to DP master class 1 services the CP 5613 also offers DP master class 2 services in connection with the DP programming interface according to IEC 61158 EN 50170 Devices of this type programming configu ration or operating devices are used for commissioning configuring the DP system or system operation in normal operation diagnostics The DP programming inter face provides the following services Master diagnostics Slave diagnostics Read inputs outputs of a slave Reading configuration data and Changing the slave address The extended DP functions also include non cyclic access to the parameters and measured values of a slave e g field devices of the pro cess automation intelligent HMI devices This type of slave must be supplied with extensive parameter data during startup and normal operation DS_READ DS_WRITE DS_DATA_TRANSPORT Software for PG OP communication This software enables pro gramming of the SIMATIC S5 S7 controllers through PROFIBUS in con nection with STEP 5 STEP 7 The PG OP communication for the CP 5613 is already available after installing the CP 5613 DP Base No additional software pack age is needed 5 compatible communica tion SEND RECEIVE based on the FDL interface SEND RECEIVE FDL inter face is alre
103. Scout A utility that allows easy access to process data over the OPC interface The interactive options are Displays of the configured communications channels representing the available OPC variables Monitoring reading and writing of process data SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 13 Configuring SIMATIC PC Stations 2 2 Using tools Station Configuration Options Depending on where you install the configuration tool and how the PC station is networked you have the following options e Online networked remote PC station e Online local e Offline The following descriptions illustrate when and where to use the tools and utilities in various situations Online Networked Configuration Station and PC Station Networked EJ SIMATIC NCM PC Manager PC Station_1 D Sie Fel Ea PC station amp File Edit Insert PLC View Options Window Help lej x oe Aee wal fo SS Pols E eal lt no SIMATIC PC Station 1 B SIMATIC PC Stationi71 Other station MPI 1 PROFIBUS 1 Ethernet 1 Press F1 to get Help Z Table 2 1 Tool Utility use on Configuration Station Networked PC Station SIMATIC NCM PC STEP 7 yes no is installed Station Configuration Editor no optional e can be used to adapt a target PC station toa configuration Commissioning Wizard optional recommended e for setting up PG PC e for setting up modules operation for produ
104. able services for clients and server read write infor mation report e Server functionality e VFD virtual field device services for clients and server e Bus access information ser vices live list Trace and mini database User interfaces OPC interface The OPC server contained in the respective software pack age can be used as a stan dard programming interface for the protocols PROFIBUS DP S7 communication and PROFIBUS FMS to connect automation applications to OPC capable Windows appli cations Office HMI systems etc Programming interface through C Library The programming interfaces for existing applications are implemented as a Dynamic Link Library DLL The follow ing compilers can therefore be used in conjunction with the SIMATIC NET products Microsoft Visual C C V6 0 Microsoft Visual Basic V6 0 Partner solutions from AIXO are available for Borland pro gramming interfaces e g DELPHI For solutions for other operat ing systems see the develop ment kit DK 5613 The DK 5613 can be found in the Internet at http www siemens de simatic net dk5613 T Configuration e Configuration of S7 commu The configuring tool NCM PC is a component of nication protocols S5 compatible communica tion DP protocol DP DPV1 DPV2 and FMS protocol is executed in STEP 7 NCM PC V5 1 SP2 or higher NCM PC is included in deliv ery of the PROFIBUS software
105. ables of the OPC Server known as OPC items are assigned to groups You therefore require an OPC group before you can insert OPC variables Follow the steps outlined below to create a group and add items to it SIMATIC NET NCM PC Manual Quick Start 58 C79000 G8976 C 156 01 Quick Start for the OPC Application for PROFIBUS DP Activity Ee Add Group Group Properties Enter a Group Name 5613_D Create Group Active V Update Rate in ms 500 Double click on the group entry 5613_DP to open the OPC Browser In the left hand pane you will see the hierarchically arranged name space of the OPC variables Ejorc Navigator Leaves Item Names The listed Item s will be added to Group G 3 Connections O _EB0 2 DP DP_5613 Slave005_E B0 2 DP DP_5613 Slave005_E B0 2 a DEMO O _AB0 2 DP DP_5613 5lave005_AB0 2 DP DP_5613 Slave005_4B0 2 Sy Slave005 wy A aE E _Ajis selected 27 04 2001 16 47 4 Select the following OPC items from the appropriate branches in the left hand window and transfer these variables to the right hand pane by clicking on the arrow button The structure displayed and the variable names depend on the names specified in the STEP 7 program DP CP_5613 Slave0051B0 2 DP CP_5613 Slave005QB0 2 The items are added to the group after you confirm the dialog with OK SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 59
106. ad 2 Load the configuration data using PLC gt Download Requirement In the Set PG PC Interface you must first select the following setting as access point of the application S7ONLINE STEP7 gt PC internal local Tip If you use the PC Station Wizard this setting is made automatically SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 29 Configuring SIMATIC PC Stations Offline Configuration Station and PC Station are not Connected 30 If you are working offline you will require an XDB file to transfer the data The configuration system always generates an XDB file for each configured PC station E SIMATIC NCM PC Manager PC Station_1 D Sie B EG ED Eile Edit Insert PLC View Options Window Help lel x oe Hae wal To E Be Ef eno EES SIMATIC PC Station 1 2 SIMATIC PC Static Other station 1 MPI 1 PROFIBUS 1 Etheret 1 Press F1 to get Help Z Follow the steps below to create and import an XDB file 1 Select the station on which you want to load the data in the STEP 7 project 2 Open the object properties of the station with the Station Properties menu command and select the Configuration tab 3 Here you can check and if necessary change the setting under Storage Location of the Configuration File 4 Save and compile your project you will then find the required XDB file in the folder you have selected Note T
107. ady available after installation of the CP 5613 DP Base and offers data exchange services for diag nostics and management No additional software pack age is needed Connection options for CP 5613 communications processor T PG PC JzJzJzJ Software for S7 communication 87 5613 The user interface is compati ble with software S7 5412 SIMATIC S7 system compo nents communicate with each other through S7 communica tion The S7 programming interface enables PG PC application programs access to SIMATIC S7 system com ponents The SIMATIC S7 data can be accessed easily and flexibly The following services are available with S7 communica tion Administrative services Link management Mini database e Trace Data transfer services Reading writing of variables BSEND BRECEIVE up to 64 KB per task Functions continued Software for PROFIBUS FMS interface FMS 5613 The user interface is compati ble with software FMS 5412 With the FMS programming interface Al compatible PCs can exchange data with FMS capable controllers e g S5 S7 and field devices of other manufacturers The use of the FMS protocol ensures open communication The following services are available through the FMS interface e Administrative services CRL management services FMS connection manage ment services Object directory manage ment services for clients and server e Vari
108. amming inter face can be used with this package SOFTNET DP With this the CP 5511 can be used as a PROFIBUS DP master class 1 or 2 SOFTNET DP slave for using the CP 5511 asa PROFIBUS DP slave PCMCIA card type II for PG PCs with PCMCIA slot and notebooks Used with STEP 7 ProTool NCM PC Micro Win ProTool Pro SIMATIC PDM for PG OP communication COM PROFIBUS SOFTNET S7 for S7 communication SOFTNET DP for DP e OPC servers are supplied with the communication software face with SOFTNET DP or SOFTNET S7 Application The CP 5511 enables connec _ For connecting PCMCIA slot tion of programming devices and notebooks and AT compatible PCs to PROFIBUS and to the multi point interface MPI of SIMATIC S7 2 Design PCMCIA card type II Adapter with 9 pin Sub D socket for connection to PROFIBUS Ey Functions The CP 5511 is operated The following software pack COM PROFIBUS as of V3 3 With this package the CP 5511 can be used for com missioning or diagnostics DP online functions for PROFIBUS DP systems STEP 7 Micro Win as of V2 1 Hardware base for the pro gramming software of the SIMATIC S7 200 program mable controller ProTool ProTool PRO The CP 5511 can be used as the hardware basis for the configuration tool for SIMATIC operator panels touch panels and text dis plays NCM PC drivers for the CP 5511 are included in delivery of the
109. as described in the instructions of the PC manufacturer and reconnect the power cable Attaching to the Network Activity Connect the PROFIBUS cable to the CP 5613 Connect the DP slave to the PROFIBUS cable Check the terminators on the connectors The terminators at both ends of the cable must be activated On SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 49 Quick Start for the OPC Application for PROFIBUS DP 4 2 2 Configuring the PC Station Basic Configuration of the Installed Module Activity The welcome page of the Commissioning Wizard opens Click Next SIMATIC NET Commissioning Wizard x PC Station Configuration 2 6 be Here you decide which modules in your PC will be used automatically in a STEP 7 project Setting for PROFIBUS module CP5613 CP5614 Use module for productive operation in configured PC station Module name cPser 3 CP5614 Index 4 Station address f 4 Bus profile Universal 7 Transmission rate 197 5 Kbps GD You can only modify the module parameters by adapting the configuration Use module for PG operation only Cancel Help Leave the defaults as they are and click Next On the next page confirm the configuration of the modules by clicking Next This saves the configuration and you can no longer go back You have now made the following settings in the dialog e The m
110. ase Trace Data transfer services Reading writing of variables BSEND BRECEIVE up to 64 Kbytes per task Functions continued PG PC Software for PROFIBUS FMS interface FMS 5613 The user interface is compati ble with software FMS 5412 With the FMS programming interface Al compatible PCs can exchange data with FMS capable controllers e g S5 S7 and field devices of other manufacturers The use of the FMS protocol ensures open communication The following services are available via the FMS inter face Administrative services CRL management services e FMS connection manage ment services Object directory manage ment services for clients and server e Variable services for clients and server read write infor mation report e Server functionality VFD virtual field device services for clients and server Bus access information ser vices live list Trace and mini database I i l BUS JzdzJz User interfaces OPC interface The OPC server contained in the respective software pack age can be used as a stan dard programming interface for the protocols PROFIBUS DP S7 communication and PROFIBUS FMS to connect automation applications to OPC capable Windows appli cations Office HMI systems etc e Programming interface via C Library The programming interfaces for existing applications are implemented as a Dynamic Link Library DLL The foll
111. aves e In equidistant mode signal ing by interrupt Start DP cycle End of cyclic data exchange with the DP slaves from hardware version 3 available soon Equidistant operation adjustable with STEP 7 V5 1 or higher or NCM PC V5 1 SP2 Siemens IK PI 2001 3 Functions continued ERA Siemens IK PI 2001 meena aael Connection options for PG PC CP 5613 communications processor FastLogic rapid shutdown FastLogic means that the CP 5613 can react automati cally to up to 4 plant states A fast response time and independence of the host application is achieved here for example for rapid equip ment shutdown DP programming interface The DP programming inter face DP Base of the CP 5613 has the following functions DP master class 1 including acyclic DP extensions DP master class 2 available soon incl acyclic expansions Access to the process data is directly through the dual port RAM The dual port RAM interface not only offers fast access as a DP master but also a basis for portability to other operating system envi ronments e g VXWorks QNX RMOS A library DP_BASE DLL offers administrative func tional calls initialization and management services Development kit DK 5613 The development kit DK 5613 offers access to the functions DP master class 1 including non cyclic DP expansions With the software develop ment kit DK 5613 the commu
112. ayed in HW Config Notice Make sure you arrange the components exactly the same as in the configuration list of the Station Configuration Editor see Section 2 7 If the configuration differs from the list the configuration data that you download from SIMATIC NCM PC to the PC station will no be adopted correctly SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 21 Configuring SIMATIC PC Stations my HW Config SIMATIC PC Station 2 Configuration PC Station_1 tlh Station Edit Insert PLC View Options Window Help Olele a a e aol Cf 22 x2 reer z 0 PC Profile Standard x F PROFIBUS DP S82 PROFIBUS PA SIMATIC 300 SIMATIC 400 SIMATIC PC Based Control 300 400 SIMATIC PC Station H E Controller CP Industrial Ethernet CP PROFIBUS E HMI G User Application 9 Application d OPC Server OPC Server 1 Ge Order number Firmware OPC Server for configuring all protocols as ee HE CP 5611 6GK1 561 14400 J OPC Server We a N Press F1 to get Help PC Components in the Catalog For the SIMATIC PC station you can select the following components Application Application standard application You use standard interfaces to communicate with other applications and devices via your PC module The user programs included in the application use suitable interfaces for communication such as the SAPI programming interface or
113. bility to other operating system environments e g VXWorks QNX RMOS A DP master and a DP slave library DP_BASE DLL or DPS_BASE DLL offer admin istrative function calls initial ization and management ser vices as well as diagnostic functions A transfer mechanism appli cation in the PC can be set through software as a link for data exchange between the master and slave interface In this manner defined I O data can be transferred between the master interface and the slave interface The two connected PROFI BUS networks can be oper ated with different PROFIBUS bus parameters due to their mutual independence Development kit DK 5613 The development kit DK 5613 offers access to the functions DP master class 1 including non cyclic DP expansions With the software develop ment kit DK 5613 the commu nications processors CP 5613 and CP 5614 can be inte grated in any operating sys tem environments The kit contains the necessary source code including the descriptions in PDF format and can be downloaded from the Internet Access to process data with DP 5613 The user interface is compati ble with software package DP 5412 DP master class 1 The CP 5614 FO operates as a DP master class 1 accord ing to IEC 61158 EN 50170 and handles data transfer with the distributed stations DP slaves completely indepen dently In a fixed repetitive message cycle the central controller exchanges i
114. cations can communicate with the OPC server through a stan dard open and thus manu facturer independent inter face Connection to OPC compati ble Windows applications already on the market Office 97 or HMI systems is possible PC Windows NT SIMATIC NET WinCC Office 97 OPC Manager OPC Client OPC Client SIMATIC S5 lt lt FMS OPC Server DP OPC Server S7 OPC Server S7 OPC Server TEETE a a FMS protocol DP protocol S7 communic S5 comp comm S protocol protocol uni SENDIRECEIVE Ht Il SIMATIC S7 a I al ij SIMATIC S5 SEND RECEIVE only bam G_IK10_deP0040s Ind Ethernet 57 PC Fig 3 105 System integration with OPC server a Application Under Windows NT OPC The following OPC serversare The same simple to use available PROFIBUS DP OPC server for PROFIBUS DP FMS OPC server for PROFIBUS FMS e S7 OPC servers for S7 communication alarms and events as well as S5 compatible communication SEND RECEIVE The OPC servers have e Standardized access to SIMATIC S7 and SIMATIC S5 for OPC com patible applications under Windows NT e Consistency between auto mation products from differ ent manufacturers user interface for different components e Accessibility from every computer in the LAN WAN High performance data ac cess via the Custom Inter face C e Easy to
115. ces for existing applications are implemented as a Dynamic Link Library DLL The follow ing compilers can therefore be used in conjunction with the SIMATIC NET products Microsoft Visual C C V6 0 e Microsoft Visual Basic V6 0 For Borland programming interfaces e g DELPHI part ner solutions of AIXO are available For solutions for other operat ing systems see the Develop ment Kit DK 5613 The DK 5613 can be found in the Internet http www ad siemens de net dk5613 ar Siemens IKPI October 2000 7210 Connection possibilities for PG PC CP 5614 communication processor Configuration For all packages mentioned The complete configurationof Configuration of PROFIBUS above the configuration tools the S7 communication is per DP and FMS takes place are included in the scope of formed using STEP 7 V5 0 with the enclosed supply SP3 and higher The configu COM PROFIBUS PC Edition rations generated for the PCs using STEP 7 are stored in files which are subsequently transferred to the individual PCs Diagnostics Extensive diagnostic tools are Therefore a PROFIBUS net available for installation work can be started up commissioning and opera quickly and easily with a tion for the module itself and CP 5614 for the PROFIBUS network BR Designed for Industry e Only 1 slot is required for a Process consistent data e Easy portability to other op master and slave
116. ch you intend to run this component complies with the directive 89 392 EEC Correct Usage of Software Products Warning Note the following This software may only be used for the applications described in the catalog or the technical description and only in connection with software products devices or components from other manufacturers which have been approved or recommended by Siemens Before you use the supplied sample programs or programs you have written yourself make certain that no injury to persons nor damage to equipment can result in your plant or process Copyright Siemens AG 1999 2000 All rights reserved The reproduction transmission or use of this document or its contents is not permitted without express written authority Offenders will be liable for damages All rights including rights created by patent grant or registration of a utility model or design are reserved Siemens AG Bereich Automatisierungstechnik Geschaftsgebiet Industrie Automatisierung Postfach 4848 D 90327 Nurnberg Disclaimer of Liability We have checked the contents of this manual for agreement with the hardwa re and software described Since deviations cannot be precluded entirely we cannot guarantee full agreement However the data in this manual are revie wed regularly and any necessary corrections included in subsequent edi tions Suggestions for improvement are welcomed Subject to technical change Siemen
117. ctive communication PC Station Wizard recommended no e to edit a stored configuration e to create anew configuration SIMATIC NET NCM PC Manual Quick Start 14 C79000 G8976 C 156 01 Configuring SIMATIC PC Stations Online Local Configuration Station is also PC Station EJ SIMATIC NCM PC Manager PC Station_1 D Sie i E3 E gt Eile Edit Insert PLC View Options Window Help lel x ia Aae wal fo SS e cele a B SIMATIC PC Station 1 B SIMATIC PC Station 2 Other station 1 MPI 1 PROFIBUS 1 Ethernet 1 Press F1 to get Help Table 2 2 Tool Utility use on Configuration Station PC Station SIMATIC NCM PC STEP 7 is yes installed Station Configuration Editor optional e can be used to adapt the PC station toa configuration Commissioning Wizard recommended e for setting up modules for productive communication PC Station Wizard recommended to e change local settings e edit a stored configuration e create a new configuration e import XDB files SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 15 Configuring SIMATIC PC Stations Offline Configuration Station and PC Station not Connected E SIMATIC NCM PC Manager PC Station_1 D Sie I E3 E File Edit Insert PLC View Options Window Help _ amp x a B SIMATIC PC Station 1 B SIMATIC PC St Other station 1
118. d and installation Plug amp Play Configuration Console tools Networking for Industry PC indows and user prompted commissioning Simple consistent and cost effective configuration and planning and design of a PC station Application Advanced PC Configuration The Startup Wizard guides NCM PC V5 1 SP2 offers a represents a new simple the user through all the steps new configuring tool for consistent and cost effec necessary to achieve a STEP 7 compatible PC tive startup and diagnostics ready to run PC station configuration of a PC station The Configuration Console The Startup Wizard is the central tool for config Configuration Console and uration settings and diag NCM PC mark the launch of nostics a whole new world of tools ail Functions Startup Wizard Configuration Console Settings on the OPC servers Simple and consistent The Configuration Console is delivered with the communi startup of all modules and a snap in embedded in the cations software are also exe applications supported by Microsoft Management Con cuted through the Configura Advanced PC Configuration sole that offers a range of tion Console A wizard that takes the user Ptlons for the configuration step by step through the in and diagnostics of PC hard stallation and configuration Ware components and PC of the PC station applications 3 338 Siemens IK PI 2001 Oo p m Connection options for PG PC Ad
119. d for SOFTNET Control Room PG Notebook with CP 1511 7 400 7 400 max 10 m nr l i TP Cord 9 RJ45 Sie Hil LIN il il a ITP80 FC Standard Cable TP Cord9 RJ45 Outlet RJ45 G_IK10_del0068s System configuration with CP 1511 Ideal for small installations Use in programming devic es notebooks B Technical specifications a Ordering data Order No Transmission rate Interfaces e Connection to ITP e Connection to 10BaseT Connection to PG PC Supply voltage Current consumption max Perm ambient conditions Operating temperature Transportation storage temperature e Relative humidity max Construction of the CP 1511 e Module format e Dimensions H x W x D in mm e Weight e Space requirements Construction of adapter e Dimensions H x W x D in mm e Weight e Line length 10 Mbit s 15 pin Sub D socket RJ45 PCMCIA slot type II 5 V DC 5 0 18 A 5 C to 40 C 20 C to 60 C 90 at 25 C PCMCIA type II 85 6 x 54x5 approx 30 g 1 x PCMCIA slot type II ITP RJ45 60 x 40 x 18 40 x 22 x 20 100g 40g 50 cm 20 cm CE EBET Siemens IK PI October 2000 CP 1511 gt 6GK1 151 1AA00 PCMCIA card for the connection of PG PC to Industrial Ethernet including 2 adapters for ITP and RJ45 SOFTNET S7 Windows 98 NT 4 0 2000 Pro for Industrial Ethernet German English e Version up to 8 connections S7 gt
120. data Single protocol mode e Number of connectable Data area of slave interface input data output data diagnostics data No of parallel FDL tasks to be processed max No of PG OP and S7 connections max e No of FMS connections max ar for credit 1 PDU size lt 480 bytes for credit 1 N Ordering data CP 5614 FO communication gt processor PCI card with master and slave connection to PROFIBUS incl Windows NT 4 0 2000 Pro drivers DP RAM interface for DP master and slave configuration software with electronic manual on CD ROM DP slaves max 5 C to 40 C 5 C to 60 C 40 C to 70 C 95 at 25 C PCI card 107 x 168 300 g 1 x PCI slot 122 244 bytes each 120 50 1 40 2 Order No 6GK1 561 4FA00 EERE KIPEIET Siemens IK PI October 2000 rid E Ordering data Order No Development Kit 1 DK 5613 Software Development Kit for CP 5613 CP 5614 for integration in any operating system environments on systems with PCI slot DP 5613 Windows NT 4 0 gt 6GK1 713 5DB21 3AA0 2000 Pro Software V2 1 for DP protocol on CP 5613 CP 5614 CP 5613 FO CP 5614 FO incl PG FDL and DP OPC server with electronic manual on CD ROM German English S7 5613 Windows NT 4 0 gt 6GK1 713 5CB21 3AA0 2000 Pro Software V2 1 for S7 communication on CP 5613 CP 5613 FO CP 5614 CP 5614 FO incl PG FDL and S7 OPC server with electr
121. e Hi Functions The CP 5611 is operated The following software pack COM PROFIBUS as of V3 3 The CP 5611 can be used with this package for com missioning or diagnostics DP online functions for PROFIBUS DP systems STEP 7 Micro Win as of V2 1 Hardware base for the pro gramming software of the SIMATIC S7 200 program mable controller ProTool ProTool PRO The CP 5611 can be used as the hardware basis for the configuration tool for SIMATIC operator panels touch panels and text dis plays Siemens IK PI 2001 5 3 Designed for Industry Technical specifications Data transfer rate Interfaces e Connection to PROFIBUS Supply voltage Current consumption Power loss Perm ambient conditions Operating temperature Transport storage temperature e Relative humidity Design e Module format Dimensions H x D in mm e Weight e Space required 3 362 Siemens IK PI 2001 al i ij approx Connection options for CP 5611 communications processor Connection for portable PCs to PROFIBUS e g for diag nostics and commissioning 9 6 kbit s to 12 Mbit s 9 pin Sub D socket 5 V DC 5 O5A 2 0 W 5 C to 40 C 20 C to 60 C 95 at 25 C PCI card 102 x 130 100 g 1 x PCI slot e Easy installation and com missioning CP 5611 communications processor PCI card for connecting a PG or PC to PROFIBUS CP 5611 MPI gt Consists
122. e End of cyclic data exchange with the DP slaves from hardware version 3 in preparation Equidistant mode settable as of STEP 7 V5 1 FastLogic rapid shutdown FastLogic means that the CP5614 FO can react auto matically to up to 4 plant states A fast response time and independence of the host application is achieved here e g fast switch off of devices CP 5614 FO communication processor SE Tor PC l l BUS JadzJz Functions continued DP programming interface The DP programming inter faces of the CP 5613 and CP 5614 FO are identical The DP programming inter face of the CP 5614 FO has the following functions DP slave DP master class 1 including acyclic DP exten sions DP master class 2 in preparation incl non cyclic expansions Access to the process data is directly through the Dual Port RAM The Dual Port RAM interface not only offers fast access as a DP master slave but also a basis for portability to other operating system environments e g VxWorks QNX RMOS A DP master and a DP slave library DP_BASE DLL or DPS_BASE DLL offer admin istrative function calls initial ization and management ser vices as well as diagnostic functions A transfer mechanism appli cation in the PC can be set by software as a link for data exchange between the mas ter and slave interface In this manner defined I O data can be transferred between the
123. e S7 OPC servers for S7 communication alarms and events as well as S5 compatible communication SEND RECEIVE The OPC servers have Standardized access to SIMATIC S7 and SIMATIC S5 for OPC com patible applications under Windows NT e Consistency between auto mation products from differ ent manufacturers G_IK10_deP0040s programming interfaces s Efficient data exchange for Windows NT 4 0 and Windows 2000 Pro OPC scout with browser function as OPC client and OCX data control user interface for different components e Accessibility from every computer in the LAN WAN High performance data ac cess through the Custom Interface C Easy to use through the Automation Interface VB or OCX data control which is supplied Grouping of variables items whereby a large number of data can be processed in a short time Ba Functions Open standardization of Efficient data exchange from e Several clients can run on addressing using logical names for objects of an automation component or system Support of symbols from STEP 7 a process component to a further processing applica tion e Simultaneous use of several servers by one client appli cation one OPC server at the same time e Server specific configura tion support Siemens IK PI 2001 Connection options for OPC server Functions Interfaces Automation Interface for OCX data contro
124. e SIMATIC NET 5 2000 CD if you want to use a CP 1413 in your computer or replace it with a CP 1613 PG 1613 up to version 2 1 for Windows 2000 Pro or Windows NT 4 0 Situation PG operation possible as before Steps to take None necessary S7 1613 up to version 2 1 for Windows 2000 Pro or Windows NT 4 0 Situation An S7 configuration created with the COML S7 program cannot be used Steps to take A configuration created with the COML S7 program must be recreated with SIMATIC NCM PC V5 1 Service Pack 2 or STEP 7 Version 5 1 Service Pack 2 or higher If the configuration was already created with STEP 7 XDB this STEP 7 project can continue to be used You only need to download the configuration to the CP PC station from STEP 7 Version 5 1 Service Pack 2 or higher SIMATIC NET PC Software CD 07 2001 79220 A5822 X 01 7419 93 SIMATIC NET PC Software CD 07 2001 TF 1613 up to version 2 1 for Windows 2000 Pro or Windows NT 4 0 Situation Application associations will continue to be configured as previously with the COML TF program Support of this protocol by SIMATIC NCM PC or STEP 7 with OPC is not planned The SEND RECEIVE programming interface included in the product TF 1613 can continue to be used unchanged If you use the OPC interface it will be possible in future to configure SEND RECEIVE communication with SIMATIC NCM PC or STEP 7 Steps to take None necessary SOFTNET PG up to version 3 3 for Windows 2000 P
125. e event of changes in the input data of a slave minimum load on host CPU Both alternatives can be com bined Optimum utilization of the PC is therefore possible for the application in question nism can also be used for Signalling by Interrupt for diagnostic messages from slaves In equidistant mode signal ling by interrupt Start DP cycle End of cyclic data exchange with the DP slaves from hardware version 3 in preparation Equidistant mode settable as of STEP 7 V5 1 aaa Siemens IKPI October 2000 71 5 a ng 5 Functions continued FastLogic rapid shutdown FastLogic means that the CP 5613 FO can react auto matically to up to 4 plant states A fast response time and independence of the host application is achieved here for example for rapid equipment shut down DP programming interface The DP programming inter face DP Base of the CP 5613 FO has the following functions DP master class 1 including acyclic DP exten sions DP master class 2 in preparation incl acyclic expansions Access to the process data is directly through the Dual Port RAM The Dual Port RAM interface not only offers fast access as a DP master but also a basis for portability to other operating system envi ronments e g VXWorks QNX RMOS Via a library DP_BASE DLL administrative functional calls initialization and manage ment services are offered Dev
126. e parameters you can set with NCM PC all have default settings so that in most cases problem free communication is possible SIMATIC NET NCM PC Manual Quick Start 40 C79000 G8976 C 156 01 Configuring the OPC Server 3 2 Configuring the Properties of the OPC Server To check the properties of the OPC Server or to modify parameters open the Properties dialog of the OPC Server object Properties OPC Server The General tab contains the formal parameters for identifying the OPC Server In the other tabs you can make parameter settings for the OPC server related to the specific protocols These parameters are independent of the communication connections or a DP master system that you configure separately The table below provides you with an overview of the possible parameter settings depending on the protocol or service type SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 41 Configuring the OPC Server Table 3 1 Parameter Function Scan cycle time Possible Settings Significance Here you make the settings to control updating by the OPC Server The scan cycle time decides how often the OPC server updates the values of the OPC items Can be set for a specific protocol DP FDL SEND RECEIVE X FMS S7 ISO TCP SEND RE CEIVE X Access protection You can specify the access rights to individual variables or variable groups for each specific
127. e read or written to or from the PROFIBUS application in 1 ms through the applicable PROFIBUS CP regardless of the physical characteristics of the bus Ji 4 D CP 5613 with CP 5613 with CP 5412 A2 with CP 5X11 with d y DP RAM access DP 5613 Win NT DP 5412 WinNT SOFTNET DP s D 1 The CP 5613 is the successor type to CP 5412 A2 Al M Fig 3 109 Performance in the case of almost equal CPU loading CPU loading and A comparison of event access time access through Interrupt and polling access shows that the CPU loading in CP 5613 can be reduced considerably using the event filter mechanism at the same data throughput CP 5613 Other CPs with events through DP RAM access with polling E CPU load at same data thruput to get current data of a slave G_IK10_deP0036s Fig 3 110 Comparison of CPU loading for event polling access Performance data of the PROFIBUS CP CP 5613 CP 5613 FO CP 5614 CP 5614 FO CP 5412 A2 CP 5611 CP 5511 No of connectable DP slaves max 122 122 64 60 60 No of parallel FDL tasks to be processed max 120 120 118 100 32 No of PG OP and S7 connections max 50 50 29 8 8 No of FMS connections max 402 402 32 Note The CP 5613 is the successor type to CP 5412 A2 1 for credit 1 PDU size lt 480 byte 2 for credit 1 Siemens IK PI 2001 Connection options for PG PC GRIO OPC server T L see Overview PC Windows NT
128. echanism for relieving the host CPU OPC servers are supplied with the communication soft ware E Application The CP 5613 enables connec The CP 5613 provides high a Design Short PCI card It is connected to the electri It is connected to the optical PROFIBUS with integrated interface and OBT by e bus cable with 2 bus con nectors or 830 1T PROFIBUS connect ing cable to an optical bus terminal OBT for PROFIBUS DP Direct connection to the opti cal PROFIBUS with integrated interface by CP 5613 FO E Functions PROFIBUS DP Event filter mechanism The new event filter mecha nism can be used additionally f Signalling by Interrupt for diagnostic messages from slaves In equidistant mode signal ling by interrupt Start DP cycle End of cyclic data ex change with the DP slaves from hardware version 3 in preparation Equidistant mode settable as of STEP 7 V5 1 peter ese Siemens IKPI October 2000 I 5F ng 5 Functions continued FastLogic rapid shutdown FastLogic means that the CP 5613 can react automati cally to up to 4 plant states A fast response time and inde pendence of the host applica tion is achieved here for example for rapid equipment shutdown DP programming interface The DP programming inter face DP Base of the CP 5613 has the following functions DP master class 1 including acyclic DP exten sions DP master class 2
129. elopment Kit DK 5613 The Development Kit DK 5613 offers access to the functions DP master class 1 including non cyclic DP expansions With the software develop ment kit DK 5613 the commu nication processors CP 5613 CP 5614 and CP 5613 FO CP 5614 FO can be inte grated in any operating sys tem environments The kit contains the necessary source code including the descriptions in PDF format and can be downloaded from Internet 3 286 Siemens IK PI October 2000 O i Access to process data with DP 5613 The user interface is compati ble with software package DP 5412 DP master class 1 The CP 5613 FO operates as a DP master class 1 and han dles data transfer with the dis tributed stations DP slaves completely independently In a fixed repetitive message cycle the central controller exchanges information with the DP slaves e g ET 200S The DP programming interface DPLib DLL pro vides the PC programmer with function calls for data transfer In addition the DP interface offers the functions SYNC and FREEZE as well as the activa tion and deactivation of slaves The DP functional expansions with respect to master class 1 enable non cyclic read and write functions DS_READ DS_WRITE as well as alarm acknowledgement ALARM_ACk to be per formed parallel to cyclic data traffic The non cyclic trans mitted data e g parameter ization data are changed very rarely in comparison wit
130. er 73 5 2 13 OPC Scout Inserting a Group and Variables 000005 74 5 2 14 OPC Scout Displaying and Modifying Values of Variables 76 A SIMATIC NET Support and Training 0 cece eee eee eee 77 Customer Support Technical Support 06000 c ee eee ee 77 GIOSSARY ei he eee oe ee ie Ee a ke RN oh Sree let eo 79 SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C 156 01 1 Introduction and Notes on Switching to Advanced PC Configuration Advanced PC Configuration is the new tool with which you can commission a PC station as part of an industrial communication network SIMATIC NET supports the option of using Advanced PC Configuration on a central engineering station to configure not only PC stations but also for example operator stations The engineering station is a networked PC with the SIMATIC NCM PC program or STEP 7 Tools of Advanced PC Configuration Commissioning Wizard The Commissioning Wizard allows simple and consistent commissioning of all modules and user programs supported by Advanced PC Configuration It guides the user step by step through the installation and configuration of the PC station Configuration Console The Configuration Console is a snap in program embedded in the Microsoft Management Console MMC and provides a wide range of options for configuring PC hardware components and PC user programs as well as providing diagnostic functions Set
131. es for existing applications are E implemented as a Dynamic Link Library DLL The follow 4 ing compilers can therefore D be used in conjunction with i the SIMATIC NET products e Microsoft Visual C C V6 0 Microsoft Visual Basic V6 0 For Borland programming interfaces e g DELPHI partner solutions of AIXO are available For solutions for other operat ing systems see the develop ment kit DK 5613 The DK 5613 can be found in the Internet at http www siemens de simatic net dk5613 Siemens IK PI 2001 i Connection options for CP 5614 communications processor Configuration Configuration of S7 commu _ The configuring tool NCM PC is a component of nication protocols NCM PC is included in Advanced PC Configuration 5 compatible communica delivery of the PROFIBUS tion DP protocol DP DPV1 software package DPV2 and FMS protocol is executed in STEP 7 NCM PC V5 1 SP2 or higher Diagnosis Extensive diagnostic tools are Therefore a PROFIBUS available for installation network can be started up commissioning and opera quickly and easily with a tion for the module itself and CP 5614 for the PROFIBUS network Designed for Industry e Only 1 slot is required for a Higher computing perfor Easy portability to other op master and slave mance in the PC by relieving erating systems through a pa Fastest possible access to the host CPU dual p
132. es e B DELPHI part ner solutions of the AIXO Co are offered For solutions for other operat ing systems see the Develop ment Kit DK 5613 The DK 5613 can be found in the Internet http www ad siemens de net dk5613 Connection possibilities for PG PC CP 5614 FO communication processor SE Configuration For all packages mentioned The complete configuration of Configuration of PROFIBUS above the configuration tools the S7 communication is per DP and FMS takes place are included in the scope of formed using STEP 7 V5 1 with the enclosed supply and higher The configura COM PROFIBUS PC Edition tions generated for the PCs using STEP 7 are stored in files which are subsequently transferred to the individual PCs Diagnostics Extensive diagnostic tools are Therefore a PROFIBUS available for installation network can be started up commissioning and opera quickly and easily with a tion for the module itself and CP 5614 FO for the PROFIBUS network Designed for Industry Only 1 slot is required for a e Process consistent data Can also be used in a high master and slave from a DP cycle temperature industrial envi D Direct connection to the op Higher computing perfor ronment 6 tical PROFIBUS by integrat mance in the PC by relieving Flexible application by ed FOC interface the host CPU switchable assignment of Y Fastest possible access to Easy portability to other op
133. ffers the functions SYNC and FREEZE as well as the activation and deactiva tion of slaves The DP functional expansions with respect to master class 1 enable non cyclic read and write functions DS_READ DS_WRITE as well as alarm acknowledgement ALARM_ACk to be per formed parallel to cyclic data traffic The non cyclic trans mitted data e g parameter ization data are changed very rarely in comparison with the cyclic measured values and are transmitted with low priority parallel to the fast cyclic useful data transfer Interrupt acknowledgment in the master ensures reliable transfer of the interrupts from DP slaves DS_READ DS_WRITE DS_DATA_TRANSPORT Parallel operation of DP Base and DP 5613 software is not possible DP master class 2 In addition to DP master class 1 services the CP 5613 also offers DP master class 2 services in connection with the DP programming interface according to IEC 61158 EN 50170 Devices of this type programming configu ration or operating devices are used for commissioning configuring the DP system or system operation in normal operation diagnostics The DP programming interface provides the following ser vices Master diagnostics Slave diagnostics Read inputs outputs of a slave Reading configuration data and Changing the slave address The extended DP functions also include non cyclic access to the parameters and measured values
134. for the OPC Server application How to create a connection for PC applications is described in Section 2 3 5 If a connection is created for the OPC Server the properties dialog for the connection includes an additional tab OPC Properties The dialogs shown below for the various protocols provide you with an overview of the possible settings in these examples the parameters have their default settings Please note that the parameters are described in detail in the online help for each individual dialog in NCM PC FDL Connection SEND RECEIVE Interface Properties FDL connection EG General Addresses Options OPC Properties Overview Status Information Job timeout ms Max number of send retries Send buffer size 44 Bytes Max number of parallel send jobs il Number of resources for indications V Send with higher priority SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 43 Configuring the OPC Server FMS Connection Properties FMS Connection Here you assign a VFD to the FMS connection you create VFDs in the properties dialog of the OPC Server The Options button opens the dialog in which you will find the OPC tab Properties FMS Connection Options SIMATIC NET NCM PC Manual Quick Start 44 C79000 G8976 C 156 01 Configuring the OPC Server S7 Connection S7 Communication Properties S connection fe s
135. for CP 5511 and CP 5611 with electronic manual on CD ROM S7 connections max 8 8 S7 communication SOFTNET S7 Windows V6 0 gt 6GK1 704 5CW60 3AA0 Software for S7 communication incl FDL S7 OPC server NCM PC under Windows NT 4 0 WS server Windows 2000 Pro server for CP 5511 and CP 5611 with electronic manual on CD ROM SOFTNET DP Slave Windows V6 0 6GK1 704 5SW60 3AA0 Software for DP slave incl OPC server under Windows NT 4 0 WS server Windows 2000 Pro server for CP 5511 and CP 5611 with electronic manual on CD ROM Manual CP 5613 CP 5614 and SOFTNET for PROFIBUS Paper version Including Description of the interfaces FMS DP S7 FDL OPC server configuration tools German e English 6GK1 971 5DA00 0AA0 6GK1 971 5DA00 0AA1 SIMATIC NET gt 6GK1 704 0AA00 3AA2 Software Update Service For Industrial Ethernet PROFIBUS OPC server including manuals on CD ROM German English SIMATIC NET Manual Collection 6GK1 975 1AA00 3AA0 Electronic manuals for communication systems protocols products on CD ROM German English vy Siemens IK PI 2001 3 365 Oo o
136. for PG OP communication STEP 5 from V7 1 STEP 7 from V4 02 and K4 02 5 for SIMATIC S5 S7 incl OPC server for CP 1411 CP 1511 with electronic manual on CD ROM German English SOFTNET Manual for Industrial Ethernet Hardcopy Including Description of the interfaces S7 S5 compatible communication OPC server configuring tool German English SIMATIC NET gt Software Update Service for Industrial Ethernet PROFIBUS OPC server including manuals on CD ROM vy Electronic Manuals gt Communications systems protocols products on CD ROM German English 6GK1 704 1CW33 3AA0 6GK1 704 1PW33 3AA0 6GK1 971 1EA00 0AA0 6GK1 971 1EA00 0AA1 6GK1 704 0AA00 3AA2 6GK1 975 1AA00 3AA0 Industrial Ethernet System interfacing for PG PC CP 1511 communication processor Industrial Overview For connecting Designed for use in programming devices industrial environments notebooks with PCMCIA slot to Industrial Ethernet PCMCIA card type Il Interfaces Industrial Twisted Pair RJ45 for office applica e Communication services via ISO or TCP IP transport pro tocols A PG OP communication tons S7 communication OPC servers are supplied i with the communication 5 compatible communi eonware cation SEND RECEIVE Application The CP 1511 is an Ethernet In conjunction with all SOFT Two adapters are supplied card which can be operated NET packages for Ind
137. g in the right hand half of the window if it is not already open You open the catalog by clicking on the following button Hardware Catalog ET 2008 T 8 160 B 16DI AC B 16D1 16D0 B 16D0 B 16DO AC B 16D0 24 B 18RO AC B 24D1 8D0 B 24D1 8D0 2 B 32D B 32D1 0 2ms B 32D0 B 4 8A B 4 8A B 4Al ma B AAl BES 133 0BL00 0XB0 Digital 1 0 16D1 x 24 VDC 16D0 x 24 VDC 0 5 A SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 55 Quick Start for the OPC Application for PROFIBUS DP Ali PCStation Configuration DP_5613_Test 0 PC Ji OPC Server a e 1 B 16D1 716D0D0 DP Slot f Module 7 Order number l ddress GAddress Comme FADE L nvang ota fk 7 Linvversal mahae ee ee i 4 2 8 HW Config Downloading the Configuration Finishing configuration and returning to the Commissioning Wizard Activity B 2 3 Close HW Config 4 Activate the Commissioning Wizard dialog box and click the Next button SIMATIC NET NCM PC Manual Quick Start 56 C79000 G8976 C 156 01 Quick Start for the OPC Application for PROFIBUS DP 4 2 9 STEP 7 Commissioning Wizard Specifying the Use of Symbol Files Completing Commissioning Activity 1 SIMATIC NET Commissioning Wizard x Symbols 5 6 be Here you specify whether and which symbolic names will be used for ag communication IF you want to use symbolic names for t
138. ges mentioned above the configuration tools are included in the scope of supply The complete configuration of the S7 communication is per formed using STEP 7 V5 1 and higher The configurations generated for the PCs using STEP 7 are stored in files which are sub sequently transferred to the individual PCs Configuration of PROFIBUS DP and FMS takes place with the enclosed COM PROFIBUS PC Edition Diagnostics Extensive diagnostic tools are available for installation commissioning and opera tion for the module itself and for the PROFIBUS network Therefore a PROFIBUS net work can be started up quickly and easily with a CP 5613 FO Designed for Industry e Fastest possible access to process data via Dual Port RAM e Short response time with FastLogic e Process consistent data from a DP cycle Direct connection to the op tical PROFIBUS by integrat ed FOC interface e Higher computing perfor mance in the PC by relieving the host CPU e Fast commissioning by Plug amp Play and diagnostic tools e Easy portability to other op erating systems by a Dual Port RAM interface Can also be used in a high temperature industrial environment gestern Ste Siemens IKPI October 2000 IH 7A me i sun DH T Technical specifications Baud Rates Interfaces e Connection to PROFIBUS e External power supply optical via standard external power supply Supply vol
139. gh in tegrated FOC interface Software for PROFIBUS FMS interface FMS 5613 The user interface is compati ble with software FMS 5412 The FMS programming inter face allows AT compatible PCs to exchange data with FMS capable controllers e g S5 S7 and field devices of other manufacturers The use of the FMS protocol ensures open communication The following services are available through the FMS interface Administrative services CRL management services FMS connection manage ment services Object directory manage ment services for clients and server e Variable services for clients and server read write infor mation report e Server functionality e VFD virtual field device services for clients and server e Bus access information ser vices live list Trace and mini database The configuring tool NCM PC is included in delivery of the PROFIBUS software package Therefore a PROFIBUS network can be started up quickly and easily with a CP 5613 FO Higher computing perfor mance in the PC by relieving the host CPU Fast commissioning through Plug amp Play and diagnostic tools Implementation for motion control applications possi ble through support of the equidistant mode User interfaces OPC interface The OPC server contained in the respective software pack age can be used as a stan dard programming interface for the protocols PROFIBUS DP S7 commun
140. gn Short PCI card Diagnostic LEDs It is connected to the optical 2 Duplex sockets for con nection of plastic and PCF FOCs with 2 simplex plugs each to the optical PROFI BUS Connection for external power supply This means data transmission on the op tical line is not interrupted when the PC is switched off Parallel operation of up to 4 CPs The module is installed via PCI standard mechanisms plug amp play PROFIBUS with integrated interface by e Plastic and PCF FOCs with simplex plugs It is connected to the electri cal PROFIBUS by e Plastic and PCF FOC with simplex plugs to an OBT Functions PROFIBUS DP Event filter mechanism The new event filter mecha Access to process data with DP Base The CP 5613 FO is operated as a PROFIBUS DP master module which holds the pro cess image input output and diagnostic data in the Dual Port RAM memory area on the CP The high perfor mance data exchange with the PROFIBUS slaves is han dled independently by the CP 5613 FO hardware The user has direct access to the Dual Port RAM The process data of the slaves are always consistent i e the user gets the data from one and the same DP cycle Parallel operation of DP Base and DP 5613 software is not possible The user receives up to date data via two access mecha nisms e Cyclic polling of the DP slaves higher load on host CPU e Signalling by new kind of event filter mode in th
141. guration Activity Change Settings SIMATIC PC Station SIMATIC PC Station Click the Finish button This starts NETPRO of STEP 7 SIMATIC NET NCM PC Manual Quick Start 68 C79000 G8976 C 156 01 Quick Start for the OPC Application for Industrial Ethernet 5 2 7 STEP 7 NetPro Inserting an S7 Connection Activity Sample_lE Network C Programme S7proj Sample_ Ethernet 1 Industrial Ethernet SIMATIC PC Station 1 SIMATIC 400 1 OPC Se CP CPU CP rver 1613 416 1 443 1 a 2 The S7 400 device is automatically entered as the connection partner and the connection type S7 connection will be set 3 Confirm this dialog by clicking Apply You have now configured the connection between the PC station and the S7 400 SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 69 Quick Start for the OPC Application for Industrial Ethernet 5 2 8 STEP 7 NetPro Downloading the Configuration Finishing Configuration and Returning to the Commissioning Wizard Activity 1 a 2 Select both the PC station and the S7 device by first clicking on the PC sta tion and then on the S7 device while holding down the CTRL key 3 Close NetPro 5 Activate the Commissioning Wizard dialog box and click the Next button 5 2 9 STEP 7 Commissioning Wizard Specifying the
142. guration data inform the DP master in the PC station of the data and address areas of the attached slaves Depending on the type of slave this information is either implicitly linked to the entry in the catalog or must be configured here additionally as for example when using an intelligent DP slave such as the CP 342 5 Follow the steps below 1 You have already placed the applications and modules as described in Section 2 3 3 2 After you have taken the module from the catalog you can select it and create a DP master system using the Insert menu command 3 Select the application that will address the master system the DP slaves is HW Config SIMATIC PC Station 1 ioj x Station Edit Insert PLC View Options Window Help Dis s 2 3 SI dolia CIES 22 a HU SIMATIC PC Station 1 Configuration PC Station_1 The applications you have created are now ready to be assigned d Application 1 You can then see the DP master system you have created SSS 2 Index Module Order number Firmware MPI address Comment 1 a 2 CP 5611 6GK1 561 14400 Press F1 to get Help Chg Ui SIMATIC NET NCM PC Manual Quick Start 24 C79000 G8976 C 156 01 Configuring SIMATIC PC Stations Now insert the DP slaves you want to be addressed by the application from the catalog ar HW Config 5 SIMATIC PC Station 1 Configuration PC Station_1 HERA
143. h the cyclic measured values and are transmitted with low priority parallel to the fast cyclic useful data transfer Interrupt acknowledgment in the master ensures reliable transfer of the interrupts from DP slaves DS_READ DS_WRITE DS_DATA_TRANSPORT Parallel operation of DP Base and DP 5613 software is not possible DP master class 2 In addition to DP master class 1 services the CP 5613 FO also offers DP master class 2 services in connection with the DP programming interface according to IEC 61 158 EN 50170 Devices of this type programming con figuration or operating devices are used for commis sioning configuring the DP system or system operation in normal operation diagnos tics The DP programming interface provides the follow ing services Master diagnostics Slave diagnostics Read inputs outputs of a slave Reading configuration data and Changing the slave address The extended DP functions also include non cyclic access to the parameters and measured values of a slave e g field devices of the pro cess automation intelligent HMI devices This type of slave must be supplied with extensive parameter data dur ing startup and normal opera tion DS_READ DS_WRITE DS_DATA_TRANSPORT Configuration of PROFIBUS DP takes place with the enclosed COM PROFIBUS PC Edition Software for PG OP communication This software enables pro gramming of the SIMATIC
144. h the wizard in Section 2 6 You will find examples in the Quick Start in Chapters 4 and 5 Creating and Managing Objects Ie PC Station_1 C Siemenz St separate object of the type PC After starting SIMATIC NCM PC you either open an existing project or create a new one You use projects to manage your configurations consisting of all or part of the stations of your plant Objects are arranged in a hierarchical structure within a project For each PC station you create a station PC Station Application These objects in turn contain the configuration and parameter data of the hardware and software These objects are then used to assign the communications services The objects are created with HW Config as shown in Section 2 3 3 SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 19 Configuring SIMATIC PC Stations Notice The name selected here for the PC station identifies the PC configuration If you define a configuration for the local PC with NCM PC the name you select must be identical to the name of the actual local configuration If you define a con figuration for a remote PC station the name must not be identical to that of the actual local configuration Otherwise the local configuration would be overwritten when you download Follow the steps below 1 Start up the SIMATIC NCM PC Manager 2 You can create the stations with the
145. he station name must be identical in the configuration and on the local PC station Entry in the Station Configuration Editor 5 Copy the XDB file onto a data medium that the destination station can access 6 Import the XDB file into your destination station using the Station Configuration Editor SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 Configuring SIMATIC PC Stations 2 5 Commissioning Wizard When configuring the SIMATIC NET communications modules for the first time you are supported by the Commissioning Wizard The Commissioning Wizard takes you through the necessary steps for commissioning modules and the further steps for commissioning a PC station with configured communication Tips e Refer to the examples in the Quick Start chapters in this manual e The tools and utilities were described in Section 2 2 Station Configuration The wizard opens e when you boot the PC station after inserting an additional module e when you select the appropriate menu command in the Configuration Console tool e when you select it in the Start menu How to Use the Wizard The basic steps are outlined below 1 When you first configure the modules all those that had not been detected previously are detected For each module you then set the operating mode and if you select Configured mode the network related parameters for initial configuration 2 After the Commissioning Wizard has
146. he variables you must create a symbol file Please enter the name of an existing symbol file or create a new symbol file with the Symbol File Configurator Use a symbol file File name C MySymbolFile ssd Browse Dreate modity the symbol He with the Symbol File lantqurator Start Additional settings for PROFInet and SIMOTION Advanced Symbols lt Back Cancel Help Click the Next button The last dialog box of the Commissioning Wizard appears Click the Finish button to complete your work with the wizard 4 2 10 OPC Scout Establishing a Connection to the OPC Server The OPC Scout as Client for Commissioning and Testing You can now access the objects of the programmable controller with any OPC client The OPC Scout ships with this product as the tool for commissioning and testing Follow the steps outlined below to set the values of the variables of the DP slave using the OPC Scout SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 57 Quick Start for the OPC Application for PROFIBUS DP Activity Start the OPC Scout in the Start menu Start gt SIMATIC gt SIMATIC NET gt PROFIBUS gt CP5613_CP5614 gt OPC Scout Servers and groups Servers B Local Server s EE OPC SimaticNET tl Remote Server s 4 2 11 OPC Scout Inserting a Group and Variables Organizing Process Variables The process vari
147. i 57 connection 1 from 2 selected Insert Chg 7 SIMATIC NET NCM PC Manual Quick Start 26 C79000 G8976 C 156 01 Configuring SIMATIC PC Stations 2 Enter the desired connection type When selecting the destination station note the following After creating a new project in SIMATIC NCM PC you will normally find that the required destination station for example an S7 station does not exist You then have the following options Create an unspecified connection Select unspecified as the connection partner In the Properties dialog box you can then set the address parameters for the connection partner Create a proxy object Create an Other Station You then network this station by assigning the necessary interface types in the Properties dialog This method is advisable if you intend to assign several connections to this partner station on the same interface in your project Create a copy of an S7 station Insert the copy of an S7 station that you have created using STEP 7 in another project You can then select this S7 station as your destination station SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 27 Configuring SIMATIC PC Stations 2 4 Downloading the Configuration Data to the PC Station Notice Downloading as described below only results in successful installation of the communications services on your PC station if the arrangement of the components
148. ication and PROFIBUS FMS to connect automation applications to OPC capable Windows appli cations Office HMI systems etc Programming interface through C Library The programming interfaces for existing applications are implemented as a Dynamic Link Library DLL The follow ing compilers can therefore be used in conjunction with the SIMATIC NET products e Microsoft Visual C C V6 0 Microsoft Visual Basic V6 0 For Borland programming interfaces e g DELPHI part ner solutions of AIXO are available For solutions for other operat ing systems see the develop ment kit DK 5613 The DK 5613 can be found in the Internet at http www siemens de simatic net dk5613 NCM PC is a component of Advanced PC Configuration Easy portability to other op erating systems through a dual port RAM interface Can also be used in high temperature industrial envi ronments Siemens IK PI 2001 5 Technical specifications Baud rates Interfaces e Connection to PROFIBUS e External power supply optical through standard external power supply Supply voltage from PCI Current consumption from 5 VDC e from 12 V DC Power loss Supply voltage optional external power supply e Current consumption e Power loss Perm ambient conditions Operating temperature Without fan With fan air current 0 5 m s Transport storage temperature e Relative humidity
149. ications to S7 communication and S5 compatible communication SEND RECEIVE Builds on the software pro gramming interfaces Efficient data exchange for Windows NT 4 0 and Win dows 2000 Pro OPC Scout with browser function as OPC client and OCX data control only S7 OPC server ate user interface for differ ent components Can be accessed from every computer in the LAN WAN High performance data ac cess via the Custom Inter face C e Easy to use via the automation interface VB or the OCX data control sup plied S7 and FMS OPC server only Functions Open standardization of ad dressing via logical names for objects contained in an automation component or automation system Support of symbols from STEP 7 Efficient data exchange be tween a process component and a further processing ap plication Simultaneous utilization of two or more servers by one client application Simultaneous execution of two or more clients on one OPC server application e Server specific configura tion support Interfaces Custom interface for high performance C applications Automation interface for easily created Visual Basic or comparable applications OCX data control for direct integration in Win dows applications that support COM DCOM S7 OPC server only aa Siemens IKPI October 2000 240 Industrial Ethernet Introduction System interfacing for P
150. ily and flexibly The following services are available with S7 communica tion Administrative services Link management Mini database e Trace Data transfer services Reading writing of variables BSEND BRECEIVE up to 64 KB per task Software for PROFIBUS FMS interface FMS 5613 The user interface is compati ble with software FMS 5412 The FMS programming inter face allows Al compatible PCs to exchange data with FMS capable controllers e g S5 S7 and field devices of other manufacturers The use of the FMS protocol ensures open communica tion The following services are available through the FMS interface e Administrative services CRL management services e FMS connection manage ment services Object directory manage ment services for clients and server e Variable services for clients and server read write infor mation report e Server functionality VFD virtual field device services for clients and server e Bus access information ser vices live list Trace and mini database User interfaces OPC interface The OPC server contained in the respective software pack age can be used as a stan dard programming interface for the protocols PROFIBUS DP S7 communication and PROFIBUS FMS to connect automation applications to OPC capable Windows appli cations Office HMI systems etc Programming interface through C Library The programming interfac
151. in the configuration data is identical with that of the configuration data on the PC station See also Section 2 3 3 Online Mode The online mode allows you to download the configuration data directly to a PC station attached to the network MPI PROFIBUS or Ethernet or to load the data on the local PC station if you are using this as the configuration station e Online Networked Configuration Station and PC Station Networked SIMATIC NCM PC Manager PC Station_1 D Sie i l E3 ED Eile Edit Insert PLC View Options Window Help lej x Dis Eaa al e E safo aS fl lt No SIMATIC PC Station 1 2 SIMATIC PC Station 71 Other station Press F1 to get Help Z Download Follow the steps below 1 Switch the PG PC station online 2 Select the station you want to download to 3 Download the configuration data with PLC gt Download Make sure you set the correct interface in Set PG PC Interface SIMATIC NET NCM PC Manual Quick Start 28 C79000 G8976 C 156 01 Configuring SIMATIC PC Stations e Online Local Configuration Station is also PC Station E SIMATIC NCM PC Manager PC Station_1 D Sie BEI ES E File Edit Inset PLC View Options Window Help _ e x Dle al e 3 Saf ey 2 SIMAT B SIMATIC PC Station Other station 1 MPI 1 PROFIBUS 1 Press F1 to get Help Follow the steps below 1 Select the station you want to lo
152. in the input data of a slave minimum load on host CPU bined Optimum utilization of the PC is therefore possible for the relevant application The new event filter mecha nism can also be used for Signaling by interrupt for di agnostic messages from slaves In equidistant mode signal ing by interrupt Start DP cycle End of cyclic data exchange with the DP slaves from hardware version 3 available soon Equidistant operation adjust able with STEP 7 V5 1 or higher or NCM PC V5 1 SP2 Siemens IK PI 2001 943 3 Connection options for PG PC CP 5614 communications processor Functions continued FastLogic rapid shutdown FastLogic means that the CP 5614 can react automati cally to up to 4 plant states This achieves a fast response time and independence from the host application e g for rapid equipment shutdown DP programming interface The DP programming inter faces of the CP 5613 and CP 5614 are identical The DP programming inter face of the CP 5614 has the following functional scope DP slave DP master class 1 including acyclic DP extensions DP master class 2 available soon incl non cyclic DP expansions Access to the process data is directly through the dual port RAM The dual port RAM interface not only offers fast access as a DP master slave but also a basis for portability to other operating system environments e g VxWorks QNX RMOS
153. ins a brief description of SIMATIC NCM PC Help gt Getting Started Here you will find brief instructions on how to create a PC station its applications and modules For more detailed information you can go from here to the PC topics in the main help system These instructions are available only in Help on SIMATIC NCM PC In STEP 7 select the Help menu directly Help Here you will find help topics relating to the PC station under Configuring Hardware SIMATIC PC Station Configuring Connections for a SIMATIC PC Station SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 17 Configuring SIMATIC PC Stations 2 3 1 Figure 2 1 18 Relationship Between SIMATIC NCM PC and STEP 7 SIMATIC NCM PC and STEP 7 are compatible with each other You can e open and edit projects that you created with SIMATIC NCM PC at any time in STEP 7 SIMATIC Manager This allows you to use additional functions for programming and configuring S7 stations Notice Optional packages are not supported by SIMATIC NCM PC If you are editing a project that was created or edited in STEP 7 it may contain components from STEP 7 optional packages If this is the case you can only edit stations using SIMATIC NET PC that do not contain components from STEP 7 optional packages e open and edit projects you created with STEP 7 SIMATIC Manager at any time in SIMATIC NCM You can edit PC stations you have already created and create
154. insert objects function 3 Opening a station object starts the HW Config tool with which you can create the configuration of a PC station consisting of modules and applications see the following page Note When you start STEP 7 a wizard is opened that helps you to create a new project In SIMATIC NCM PC this wizard is replaced by the PC Station Wizard Depending on your initial situation this wizard provides you with more extensive support for your PC station The PC Station Wizard also exists in STEP 7 SIMATIC NET NCM PC Manual Quick Start 20 C79000 G8976 C 156 01 Configuring SIMATIC PC Stations 2 3 3 Configuring a PC Station with HW Config Creating an Image of the PC Configuration To allow the configuration data sent by the configuration system to be assigned to a module or an application they must have unique identification numbers The identification number for modules applications and other components in a PC station is the index You now place your applications and modules in slots in a virtual rack in HW Config This slot number then corresponds to the index mentioned above Notice Be careful not to confuse this Index with a hardware slot for example on the PCI bus of the PC station The slot on the PCI bus is not relevant for commissioning and is not used at any point Follow the steps below Drag the components from the catalog to the list the virtual rack displ
155. ith each other through S7 communica tion The S7 programming interface enables PG PC application programs access to SIMATIC S7 system com ponents The SIMATIC S7 data can be accessed easily and flexibly The following services are available with S7 communica tion Administrative services Link management e Mini database e Trace Data transfer services Reading writing of variables BSEND BRECEIVE up to 64 KB per task The complete configuration of the S7 communication is per formed using STEP 7 V5 0 SP3 and higher The configu rations generated for the PCs using STEP 7 are stored in files which are subsequently transferred to the individual PCs Software for 5 compatible communica tion SEND RECEIVE based on the FDL interface This layer 2 based interface is used for communication between PG PC and SIMATIC S5 PG PC and SIMATIC S7 PG PC and PG PC SEND RECEIVE offers the following services Management services Connection establishment services Data transfer services This interface is contained in SOFTNET DP and SOFTNET 7 Configuration is not necessary User interfaces OPC interface The OPC server contained in the respective software pack age can be used as a stan dard programming interface for the protocols PROFIBUS DP S7 communication and PROFIBUS FMS to connect automation applications to OPC capable Windows appli cations Office
156. ith electronic manual on CD ROM in German English FMS 5613 Windows V6 0 gt Software for FMS protocol incl PG OP communication FDL FMS OPC server NCM PC under Windows NT 4 0 WS server Windows 2000 Pro server for CP 5613 CP 5614 CP 5613 FO CP 5614 FO with electronic manual on CD ROM in German English Manual CP 5613 CP 5614 and SOFTNET for PROFIBUS Paper version Including Description of the interfaces FMS DP S7 FDL OPC server configuration tools e German English PROFIBUS FastConnect gt RS 485 bus connector Plug 180 With 180 cable outlet PROFIBUS 12M bus terminal gt Bus terminal for connecting PROFIBUS stations up to 12 Mbit s with connecting cable SIMATIC NET gt Software Update Service for Industrial Ethernet PROFIBUS OPC server including manuals on CD ROM in German English SIMATIC NET Manual Collection gt Electronic manuals for communication systems protocols products on CD ROM German English vy eTe Tore Order No 6GK1 713 5DB60 3AA0 6GK1 713 5CB60 3AA0 6GK1 713 5FB60 3AA0 6GK1 971 5DA00 0AA0 6GK1 971 5DA00 0AA1 6GK1 500 0FCOO 6GK1 500 0AA10 6GK1 704 0AA00 3AA2 6GK1 975 1AA00 3AA0 Siemens IK PI 2001 5 Connection options for PG PC CP 5614 FO communications processor Overview PCI card with microproces sor for system interfacing for PCs and SIMATIC PG PC to the optical PROFIBUS w
157. ith integrated interface up to 12 Mbit s e Integrated FOC interface for direct FO connection Communication services PROFIBUS DP master interface according to IEC 61 158 EN 50 170 on a PCI card PROFIBUS DP slave inter face according to IEC 61 158 EN 50 170 on a PCI card PG OP communication with STEP 5 and STEP 7 7 communication 5 compatible communi cation SEND RECEIVE on the basis of the FDL interface PROFIBUS FMS according to IEC 61 158 EN 50170 High performance through direct dual port RAM access Event and filter mechanism for relieving the host CPU e Multiple protocol operation and parallel operation of up to 4 CPs e OPC servers are supplied with the communication software Application The CP 5614 FO enables con nection to PROFIBUS DP for SIMATIC PG PC and AT compatible PCs with PCI slot under Windows NT 4 0 and Windows 2000 It can be either a DP master or a DP slave independently of each other In this way two dif ferent PROFIBUS networks can be connected in a hierar chical structure to one PC with a PROFIBUS card and can exchange data The CP 5614 FO provides high perfor mance support for control tasks on the PC e g PC based control numeric control robot control a Design Short PCI card Diagnostic LEDs It is connected to the optical 2 duplex sockets for con nection of plastic and PCF FOCs with 2 simplex plugs each to the o
158. l for continued Custom Interface for easy to create Visual Ba direct integration in high performance C sic or similar applications Windows applications that applications support COM DCOM a e e Application X Application X Pee Application Y i OPC Client Li i Tumme lt _ 4 4 4 Server A Server B Server C Se ner OPC Se a Sener Fig 3 112 Comparison of conventional client server architecture with an OPC architecture G_IK10_deP0041s Configuration The communications parame The following demo programs Other compilers can be im ters can be completely config are supplied as standard plemented through the OPC ured using the tools in the For custom interface server however the compil software which is already in C er must support the COM installed interface Microsoft For Automation Interface with Visual Gace Component Object Model Designed for Industry e Simple use of different net e Easy integration in the sys e Easy to handle and cost works and protocols through tem environment and office effective because the OPC standard interface applications through C servers are supplied with the Reduced training and learn and Visual Basic interface communication software ing requirements Short programming times for applications 3 336 Siemens IK PI 2001 Connection options for PG PC naoa FIELD BUS nf W OPC server
159. lable for the following interfaces e CP 5511 PCMCIA card CP 5611 PCI card Integrated PROFIBUS inter faces of SIMATIC program ming devices PCs E Principle of operation SOFTNET processes the com This architecture means that packages depends on the plete protocol stack in the PC unlike CP 5613 or CP 5614 products the performance capability of the SOFTNET design and or workload of the PCs used E Functions Software for DP protocol Devices of this type program DP slave SOFTNET DP DP master class 1 SOFTNET DP offers DP master class 1 functions in conjunc tion with the CP 5511 or CP 5611 In a fixed repetitive message cycle the central controller exchanges informa tion with the DP slaves e g ET 200S The DP program ming interface DPLib DLL provides the PC programmer with function calls for data transfer In addition the DP interface offers the functions SYNC and FREEZE as well as the activation and deactiva tion of slaves e DP master class 2 n addition to DP master ass 1 services SOFTNET c DP also offers DP master class 2 services ming devices configuration devices or operating devices are used on startup on con figuring the DP system or for operating the system during normal operation e g diag nostics The DP program ming interface provides the following services Master diagnostics slave diagnos tics reading the inputs and outputs of a slave reading c
160. lder Product Versions SIMATIC NET CD 05 2000 and earlier Introduction This section describes what changes are necessary in PROFIBUS systems if you are already using a SIMATIC NET CD 05 2000 product or a previous version DP 5412 FMS 5412 PG 5412 S7 5412 up to version 5 2 with Service Pack 2 for Windows NT 4 0 or Windows 98 Situation These products are not supported by the SIMATIC NET CD 07 2001 Simultaneous installation of these products with products of the new CD 07 2001 is not permitted and is prevented Steps to take Keep using the products of the SIMATIC NET 05 2000 CD if you want to use a CP 5412 in your computer or replace it with a CP 5613 DP 5613 up to version 2 1 for Windows 2000 Pro or Windows NT 4 0 Situation A DP configuration created with the COM PROFIBUS program cannot be used Steps to take A DP configuration created with the COM PROFIBUS program must be recreated with SIMATIC NCM PC V5 1 Service Pack 2 or STEP 7 Version 5 1 Service Pack 2 or higher If the configuration was already created with STEP 7 this STEP 7 project can continue to be used You only need to download the configuration to the CP PC station from STEP 7 Version 5 1 Service Pack 2 or higher SIMATIC NET PC Software CD 07 2001 96 79220 A5822 X 01 7419 SIMATIC NET PC Software CD 07 2001 FMS 5613 up to version 2 1 for Windows 2000 Pro or Windows NT 4 0 Situation An FMS configuration created with the COM PROFIBUS program ca
161. le End of cyclic data exchange with the DP slaves from hardware version 3 available soon Equidistant operation adjustable with STEP 7 V5 1 or higher or NCM PC V5 1 SP2 Siemens IK PI 2001 5 3 Functions continued 3 346 6 Siemens IK PI 2001 amen Connection options for CP 5613 FO communications processor FastLogic rapid shutdown FastLogic means that the CP 5613 FO can react auto matically to up to 4 plant states A fast response time and independence of the host application is achieved here for example for rapid equip ment shutdown DP programming interface The DP programming inter face DP Base of the CP 5613 FO has the following functions DP master class 1 including acyclic DP extensions e DP master class 2 available soon incl acyclic expansions Access to the process data is directly through the dual port RAM The dual port RAM interface not only offers fast access as a DP master but also a basis for portability to other operating system envi ronments e g VXWorks QNX RMOS A library DP_BASE DLL offers administrative func tional calls initialization and management services Development kit DK 5613 The development kit DK 5613 offers access to the functions DP master class 1 including non cyclic DP expansions With the software develop ment kit DK 5613 the commu nications processors CP 5613 CP 5614 and CP 5613 FO CP
162. lel to cyclic data traffic The non cyclic trans mitted data e g parameter ization data are changed very rarely in comparison with the cyclic measured values and are transmitted with low priority parallel to the fast cyclic useful data transfer Interrupt acknowledgment in the master ensures reliable transfer of the interrupts from DP slaves DS_READ DS_WRITE DS_DATA_TRANSPORT Parallel operation of DP Base and DP 5613 software is not possible DP master class 2 In addition to DP master class 1 services the CP 5614 FO also offers DP master class 2 services in connection with the DP programming interface according to IEC 61 158 EN 50170 Devices of this type programming configu ration or operating devices are used for commissioning configuring the DP system or system operation in normal operation diagnostics The DP programming inter face provides the following services j Master diagnostics ma Slave diagnostics D Read inputs outputs D of a slave Reading configuration M data and Changing the slave address The extended DP functions also include non cyclic access to the parameters and measured values of a slave e g field devices of the pro cess automation intelligent HMI devices This type of slave has to be supplied with extensive parameter data during startup and normal operation DS_READ DS_WRITE DS_DATA_TRANSPORT Configuration of PROFIBUS DP takes
163. llowing services are available with S7 communica tion Administrative services e Link management e Mini database Trace Data transfer services Reading writing of variables BSEND BRECEIVE up to 64 Kbytes per task PG PC Software for PROFIBUS FMS interface FMS 5613 The user interface is compati ble with software FMS 5412 With the FMS programming interface Al compatible PCs can exchange data with FMS capable controllers e g S5 S7 and field devices of other manufacturers The use of the FMS protocol ensures open communication The following services are available via the FMS inter face Administrative services CRL management services e FMS connection manage ment services Object directory manage ment services for clients and server Variable services for clients and server read write infor mation report e Server functionality VFD virtual field device services for clients and server Bus access information ser vices live list Trace and mini database I i l BUS JzdzJz User interfaces OPC interface The OPC server contained in the respective software pack age can be used as a stan dard programming interface for the protocols PROFIBUS DP S7 communication and PROFIBUS FMS to connect automation applications to OPC capable Windows appli cations Office HMI systems etc Programming interface via C Library The programming interfa
164. lly available for all applications after installation 3 280 Siemens IK PI October 2000 ey Product versions Product contains OPC servers for DP 5613 PROFIBUS DP S7 5613 S7 communication FMS 5613 FMS communication SOFTNET S7 for PROFIBUS S7 communication SOFTNET DP PROFIBUS DP SOFTNET DP slave PROFIBUS DP slave CP 5613 5614 and S5 compatible communication CP 5613 FO 5614 FO with DP Base software FDL PROFIBUS DP master in preparation Access to DP slave of the CP 5614 in preparation PGIPC Telolet CP 5613 communication processor SE e tion to PROFIBUS for SIMATIC PG PC and PCs with PCI slot under Windows NT 4 0 and Windows 2000 Professional 9 pin Sub D socket for con necting to PROFIBUS e Diagnostic LEDs Parallel operation of max 4 CPs The module is installed via PCI standard mechanisms plug amp play 1 FMS 5613 supports a maximum 2 CP 5613 5614 Access to process data with DP Base The CP 5613 is operated as a PROFIBUS DP master mod ule which holds the process image input output and diag nostic data in the Dual Port RAM memory area on the CP The high performance data exchange with the PROFIBUS slaves is handled independently by the CP 5613 hardware The user has direct access to the Dual Port RAM The process data of the slaves are always consistent i e the user gets the data from one and the same D
165. mance cP 1613 Constantly high communication performance i CP 1413 i Constant communication performance i LI CP 1411 CP1511 I Fluctuating communication performance 5 3 7 1 The CP 1613 is the successormodule to the CP 1413 a A Fig 4 54 Comparison of communication performance characteristics li CPU load The communication must Whereas under these condi The stated throughput figures i share the PC resources with tions e g the CP 1411 1511 represent average values other applications especially only lets through an average HMI In general therefore of about 80 messages with a less than 25 of the host CPU strongly fluctuating curve the time remains available for CP 1613 still offers maximum communication throughput 5 Thruput frames s PC processor performance for communication ee 100 i i 75 i E E 50 H i E i 25 ia H i a ae T ka m m 7 g 2 3 CP 1413 CP 1411 CP 1613 z CP 1511 o Fig 4 55 CP 1613 throughput at 20 CPU availability for communication 4 112 4 Siemens IK PI October 2000 sd System interfacing for PG PC OPC server Industrial Ethernet Introduction D Industrial E Overview OPC servers are contained PC Windows NT and Windows 2000 Pro SIMATIC NET WinCC Office 97 OPC Manager OPC Client OPC Client ee ell SIMATIC S5 PROFIBUS
166. max Design e Module format e Dimensions W x H in mm e Weight approx e Space required Performance data Single protocol mode e No of connectable DP slaves max e No of parallel FDL tasks o be processed max No of PG OP and S7 connections max e No of FMS connections max 1 For credit 1 PDU size lt 480 byte 2 For credit 1 Siemens IK PI 2001 Connection options for PG PC CP 5613 FO communications processor 9 6 kbit s to 12 Mbit s 2 x duplex socket FO Low voltage socket 3 5 mm 1 3 mm Haye 5V DC 5 12 V DC 5 14A 0 3 A 7W 9 12 DE O4A 3 6 4 8 W 5 C to 40 C 5 C to 60 C 40 C to 70 C 95 at 25 C PCI card 107 x 168 250 g 1 x PCI slot 122 120 50 1 402 E Ordering data Order No CP 5613 FO communications gt 6GK1 561 3FA00 processor PCI card for connection to PROFIBUS DP incl Windows NT 4 0 WS server Windows 2000 Pro server driver DPRAM Interface for DP master incl PG and FDL configuration software with electronic manual on CD ROM Development kit 1 DK 5613 Software development kit for CP 5613 CP 5614 for integration in any operating system environments on systems with PCI slot DP 5613 Windows V6 0 Software for DP protocol incl PG OP communication FDL DP OPC server NCM PC under Windows NT 4 0 WS server Windows 2000 Pro server for CP 5613 CP 5614 CP 5613 FO CP 5614 FO with electronic
167. ment Kit for CP 5613 CP 5614 for integration in any operating system environments on systems with PCI slot DP 5613 Windows NT 4 0 gt 6GK1 713 5DB21 3AA0 2000 Pro Software V2 1 for DP protocol on CP 5613 CP 5614 CP 5613 FO CP 5614 FO incl PG FDL and DP OPC server with electronic manual on CD ROM German English S7 5613 Windows NT 4 0 2000 Pro Software V2 1 for S7 communication on CP 5613 CP5614 CP 5613 FO CP 5614 FO incl PG FDL and S7 OPC server with electronic manual on CD ROM German English FMS 5613 Windows NT 4 0 gt 6GK1 713 5FB21 3AA0 2000 Pro Software V2 1 for FMS protocol on CP 5613 CP5614 CP 5613 FO CP 5614 FO incl PG FDL and FMS OPC server with electronic manual on CD ROM German English Manual CP 5613 CP 5614 and SOFTNET for PROFIBUS Including Description of the interfaces FMS DP S7 FDL OPC server configuration tools gt 6GK1 713 5CB21 3AA0 e German gt 6GK1 971 5DA00 0AA0 English gt 6GK1 971 5DA00 0AA1 SIMATIC NET gt 6GK1 704 0AA00 3AA2 Software Update Service For Industrial Ethernet PROFIBUS OPC server including manuals on CD ROM German English Electronic manuals gt 6GK1 975 1AA00 3AA0 Communication systems protocols products on CD ROM German English 1 Download from Internet under http www ad siemens de net dk5613 PGIPC Te Tolet CP 5614 communication processor T aa Overview
168. munication soft ware 5 It is connected to the optical PROFIBUS with integrated interface and OBT through e Bus cable with 2 bus connectors or 830 1T PROFIBUS connecting cable to an optical bus terminal OBT for PROFIBUS DP Direct connection to the opti cal PROFIBUS with integrated interface through CP 5613 FO E Functions PROFIBUS DP Event filter mechanism The new event filter mecha Access to process data with DP Base The CP 5613 is operated as a PROFIBUS DP master mod ule which holds the process image input output and diag nostic data in the dual port RAM memory area on the CP The high performance data exchange with the PROFIBUS slaves is handled independently by the CP 5613 hardware The user has direct access to the dual port RAM The process data of the slaves are always consistent i e the user gets the data from one and the same DP cycle Parallel operation of DP Base and DP 5613 software is not possible The user receives up to date data through two access mechanisms e Cyclic polling of the DP slaves higher load on host CPU Signaling through new kind of event filter mode in the event of changes in the input data of a slave minimum load on host CPU Both alternatives can be com bined Optimum utilization of the PC is therefore possible for the relevant application nism also can be used for Signaling by interrupt for diagnostic messages from sl
169. n PG PC E i 1 i 7 400 Runtime PC With application software Fig 3 113 PC configuration with STEP 7 or NCM PC i iW iH EE i A Runtime PC With application software G_IK10_deP0154s Siemens IK PI 2001 BESTA Connection options for PG PC Advanced PC Configuration Designed for Industry Simple use of different net Reduced training and learn Uniform procedure and con works and protocols through ing requirements figuration functionality as for standard configuration Short setting times for com STEP 7 munication Technical specifications Advanced PC Configuration Ordering data Order No Supported modules CP 5511 CP 5611 CP 5613 Advanced PC Configuration Included in delivery are the follow CP 5613 FO CP 5614 ing products CP 5614 FO 57 5613 CP 5611 compatible PROFIBUS DP 5613 interfaces of PCs PGs lt FMS 5613 Protocols e S5 compatible communication SOFTNET DP slave e S7 communication for PROFIBUS DP SOFTNET DP for PROFIBUS FMS SOFTNET S7 for PROFIBUS 7 SIMATIC NET CD 07 2001 Operating systems Windows NT 4 0 SP 6a Upgrade e Windows 2000 SP1 for Professional and servers Siemens IK PI 2001 Overview A D pplication esign Connection options for PG PC CP 5613 communications processor BE A l The CP 5613 enables connec tion to PROFIBUS for SIMATIC PG PC and PCs with PCI
170. n against e Safeguards previous invest e Increases availability of the communication failure in the ments due to the use of ex PC application e g PC S7 event of a fault in the double isting applications and the through redundant commu bus or in redundant rings flexible application possibili nication Simplifies communication of ties a PC application with the No additional programming SIMATIC S7 400H system required for PC and H systems Ordering data Order No S7 REDCONNECT Windows NT 4 0 6GK1 716 0HB13 3AA0 V1 3 Software for fail safe S7 communication via redundant networks Industrial Ethernet PROFIBUS under Windows NT 4 0 can be operated with CP 5412 A2 and CP 1613 including S7 OPC server with electronic manual on CD ROM German English S7 REDCONNECT 1613 gt 6GK1 716 0HB13 3AA4 Windows NT 4 0 Upgrade V1 3 Expansion of S7 1613 Windows NT 4 0 to S7 REDCONNECT Windows NT 4 0 on CD ROM German English 4 120 A 1 Siemens IK PI October 2000 E Industrial Ethernet System interfacing for PG PC CP 1411 communication processor Industrial Overview For connecting PG PC Designed for use in to Industrial Ethernet industrial environments Communication services ISA card via ISO or TCP IP transport iniartapes protocols DON AUI Industrial Twisted Pair PG OP communication RJ45 for office applica S7 communication tions 5 compatible communi cation SE
171. n to PROFIBUS for SIMATIC PG IPC and PCs with PCI slot under Windows NT 4 0 and Windows 2000 whereby it can operate both as DP master and as DP slave independently of one another PCI card with microproces sor for system interfacing for PCs and SIMATIC program ming devices IPC to PROFIBUS up to 12 Mbit s Communication services PROFIBUS DP master in terface according to IEC 61158 EN 50 170 on a PCI card PROFIBUS DP slave inter face according to IEC 61 158 EN 50 170 on a PCI card PG OP communication with STEP 5 and STEP 7 S7 communication This means that two different PROFIBUS networks can be connected to a PC in a hierar chic structure using one PROFIBUS card and data can be exchanged between the networks 5 compatible communi cation SEND RECEIVE on the basis of the FDL interface PROFIBUS FMS accord ing to IEC 61 158 EN 50170 High performance through direct dual port RAM access e Event and filter mechanism for relieving the host CPU OPC servers are supplied with the communication software E G The CP 5614 provides high il performance support for con trol tasks on the PC e g PC based control numeric con trol robot control E Design Short PCI card It is connected to the electri It is connected to the optical 2 x 9 pin Sub D sockets for connecting to PROFIBUS Diagnostic LEDs Parallel operation of up to 4 CPs The mod
172. ndows up to V5 3 SOFTNET DP Slave Windows up to V1 2 CP 5611 SOFTNET DP Windows up to V5 3 IK PI 2000 and integr PB interfaces of SOFTNET S7 Windows up to V5 3 the IPCs PGs gt Prerequisite Np CP 5611 compatible SOFTNET DP Slave Windows up to V1 2 CP 5412 A2 DP 5412 Windows up to V5 2 IK 10 1999 S7 5412 Windows up to V5 2 FMS 5412 Windows up to V5 2 PG 5412 Windows up to V5 2 CP 5411 SOFTNET DP Windows up to V5 3 IK 10 1999 SOFTNET S7 Windows up to V5 3 SOFTNET DP Slave Windows up to V1 2 MPI ISA and integr Interfaces of IPCs PGs which are not compatible to CP 5611 Industrial Ethernet CP 1613 TF 1613 Windows all releases IK PI 2000 S7 1613 Windows up to V2 1 PG 1613 Windows up to V2 1 CP 1413 TF 1413 Windows all releases IK 10 1999 S7 1413 Windows all releases PG 1413 Windows all releases CP 1511 SOFTNET S7 Windows up to V3 3 IK 10 1999 SOFTNET PG Windows up to V3 3 CP 1411 SOFTNET S7 Windows up to V3 3 IK 10 1999 SOFTNET PG Windows up to V3 3 More details can be found in description SIMATIC NET PC Software CD 07 2001 chapter 4 3 and chapter 4 4 Siemens AG 2001 All Rights Reserved Technical data subject to change SIMATIC NET PC Software CD 07 2001 4 Advanced PC Configuration Switching to the SIMATIC NET PC Software CD 07 2001 4 1 Introduction to Configuration Description of Advanced PC Configuration Advanced PC Configuration is
173. ndustry Communication with Can be used in notebooks SIMATIC via standard with PCMCIA slot Ethernet cards Optimi s Optimized for small NE 2000 compatible installations E Technical specifications E Ordering data Order No Performance data SOFTNET S7 Windows 98 S7 and PG OP communication NT 4 0 senile SOFTNET S7 for Industrial Ethernet Number of operable V3 3 2 connections max 8 Software for S5 compatible communica tion SEND RECEIVE and S7 communication incl S7 OPC server for CP 1411 CP 1511 with electronic manual on CD ROM German English 4 e Version up to 8 connections S7 gt 6GK1 704 1CW33 3AA0 SOFTNET PG Windows 98 gt 6GK1 704 1PW33 3AA0 NT 4 0 2000 Pro for Industrial Ethernet Software V3 3 for PG OP communication STEP 5 from V7 1 STEP 7 from V4 02 and K4 02 5 for SIMATIC S5 S7 for CP 1411 CP 1511 with electronic manual on CD ROM German English CP 1613 and SOFTNET Manual for Industrial Ethernet Hardcopy Including Description of the interfaces S7 S5 compatible communication OPC server configuring aid German 6GK1 971 1GA00 0AA0 e English 6GK1 971 1GA00 0AA1 Electronic Manuals gt 6GK1 975 1AA00 3AA0 Communications systems protocols products on CD ROM German English SIMATIC NET gt 6GK1 704 0AA00 3AA2 Software Update Service for Industrial Ethernet PROFIBUS OPC server including manuals on CD ROM Yvy 4 126 A amp Siemens
174. nforma tion with the DP slaves e g ET 200S The DP program ming interface DPLib DLL provides the PC programmer with function calls for data transfer In addition the DP interface offers the functions SYNC and FREEZE as well as the activation and deactiva tion of slaves The DP functional expansions with respect to master class 1 enable non cyclic read and write functions DS_READ DS_WRITE as well as alarm acknowledgement ALARM_ACK to be per formed parallel to cyclic data traffic The non cyclic trans mitted data e g parameter ization data are changed very rarely in comparison with the cyclic measured values and are transmitted with low priority parallel to the fast cyclic useful data transfer Interrupt acknowledgment in the master ensures reliable transfer of the interrupts from DP slaves DS_READ DS_WRITE DS_DATA_TRANSPORT Parallel operation of DP Base and DP 5613 software is not possible e DP master class 2 In addition to DP master class 1 services the CP 5614 FO also offers DP master class 2 services in connection with the DP programming interface according to IEC 61 158 EN 50170 Devices of this type programming configu ration or operating devices are used for commissioning configuring the DP system or system operation in normal operation diagnostics The DP programming inter face provides the following services Master diagnostics al Slave diagnostics J Read i
175. nications processors CP 5613 and CP 5614 can be inte grated in any operating sys tem environments The kit contains the necessary source code including the descriptions in PDF format and can be downloaded from Internet Access to process data with DP 5613 The user interface is compati ble with software package DP 5412 DP master class 1 The CP 5613 operates as a DP master class 1 according to IEC 61158 EN 50170 and handles data transfer with the distributed stations DP slaves completely indepen dently In a fixed repetitive message cycle the central controller exchanges informa tion with the DP slaves e g ET 200S The DP program ming interface DPLib DLL provides the PC programmer with function calls for data transfer In addition the DP interface offers the functions SYNC and FREEZE as well as the activation and deactiva tion of slaves The DP functional expansions with respect to master class 1 enable non cyclic read and write functions DS_READ DS_WRITE as well as alarm acknowledgement ALARM_ACkK to be per formed parallel to cyclic data traffic The non cyclic trans mitted data e g parameter ization data are changed very rarely in comparison with the cyclic measured values and are transmitted with low priority parallel to the fast cyclic useful data transfer Interrupt acknowledgment in the master ensures reliable transfer of the interrupts from DP slaves DS_READ DS_WRITE D
176. nnot be used Steps to take An FMS configuration created with the COM PROFIBUS program must be recreated with SIMATIC NCM PC V5 1 Service Pack 2 or STEP 7 Version 5 1 Service Pack 2 or higher S7 5613 up to version 2 1 for Windows 2000 Pro or Windows NT 4 0 Situation An S7 configuration created with the COML S7 program cannot be used Steps to take A configuration created with the COML S7 program must be recreated with SIMATIC NCM PC V5 1 Service Pack 2 or STEP 7 Version 5 1 Service Pack 2 or higher If the configuration was already created with STEP 7 XDB this STEP 7 project can continue to be used You only need to download the configuration to the CP PC station from STEP 7 Version 5 1 Service Pack 2 or higher SOFTNET DP up to version 5 3 for Windows 2000 Pro Windows NT 4 0 or Windows 98 Situation Windows 98 is no longer supported A DP configuration created with the COM PROFIBUS program cannot be used It will be possible to configure Send Receive communication on the basis of the FDL interface over OPC with SIMATIC NCM PC or STEP 7 in the future Steps to take Under Windows 98 use the SIMATIC NET CD 05 2000 A DP configuration created with the COM PROFIBUS program must be recreated with SIMATIC NCM PC V5 1 Service Pack 2 or STEP 7 Version 5 1 Service Pack 2 or higher If the configuration was already created with STEP 7 this STEP 7 project can continue to be used You only need to download the configuration
177. nputs outputs D of a slave Reading configuration ll data and Changing the slave address The extended DP functions also include non cyclic access to the parameters and measured values of a slave e g field devices of the pro cess automation intelligent HMI devices This type of slave has to be supplied with extensive parameter data during startup and normal operation DS_READ DS_WRIT DS_DATA_TRANSPORT Siemens IK PI 2001 Functions continued 9 90 Siemens IK PI 2001 Connection options for CP 5614 FO communications processor Software for PG OP communication This software enables pro gramming of the SIMATIC S5 S7 controllers through PROFIBUS in con nection with STEP 5 STEP 7 The PG OP communication for the CP 5614 FO is already available after installing the CP5614 FO DP Base No additional software pack age is needed 5 compatible communica tion SEND RECEIVE based on the FDL interface SEND RECEIVE FDL inter face is already available after installation of the CP5614 FO DP Base and offers data exchange services for diag nostics and management No additional software package is needed Software for S7 communication S7 5613 The user interface is compatible with S7 5412 SIMATIC S7 system compo nents communicate with each other through S7 communica tion The S7 programming interface enables PG PC application programs access t
178. ns de Technical Support Online Services The SIMATIC Customer Support team provides you with comprehensive additional information on SIMATIC products in its online services e You can obtain the latest information On the Internet at http www ad siemens de net Using the Fax Polling no 08765 93 02 77 95 00 e Current Product Information leaflets and downloads which you may find useful for your product are available Onthe Internet at http www ad siemens de csi net Via the Bulletin Board System BBS in Nuremberg SIMATIC Customer Support Mailbox at the number 49 911 895 7100 To access the mailbox use a modem with V 34 28 8 Kbps capability whose parameters you should set as follows 8 N 1 ANSI or dial in using ISDN x 75 64 Kbps Further Support If you have further questions about SIMATIC NET products please contact your local Siemens representative You will find the addresses e In our catalog IK PI e On the Internet http Awww ad siemens de m SIMATIC NET NCM PC Manual Quick Start 78 C79000 G8976 C 156 01 Glossary Station Configuration Editor The Station Configuration Editor is the user interface of the Station Manager this allows you access to the component management of the PC station Here the components are the modules and the applications involved in communications The Station Configuration Editor can also be used for diagnostic purposes Advanced PC Configuration
179. o SIMATIC S7 system com ponents The SIMATIC S7 data can be accessed easily and flexibly The following services are available with S7 communica tion Administrative services Link management Mini database e Trace Data transfer services Reading writing of variables BSEND BRECEIVE up to 64 KB per task Software for PROFIBUS FMS interface FMS 5613 The user interface is compatible with software FMS 5412 The FMS programming inter face allows Al compatible PCs to exchange data with FMS capable controllers e g S5 S7 and field devices of other manufacturers The use of the FMS protocol ensures open communica tion The following services are available through the FMS interface Administrative services CRL management services FMS connection manage ment services Object directory manage ment services for clients and server e Variable services for clients and server read write infor mation report e Server functionality e VFD virtual field device services for clients and server e Bus access information services live list Trace and mini database User interfaces OPC interface The OPC server contained in the respective software pack age can be used as a stan dard programming interface for the protocols PROFIBUS DP S7 communication and PROFIBUS FMS to connect automation applications to OPC capable Windows appli cations Office HMI systems e
180. odule will be used for productive communication with the DP protocol This requires a configuration that will be created with SIMATIC NCM PC or STEP 7 e The module will be initialized with the PROFIBUS address 5 This means that it would be possible to download to the PC station over PROFIBUS from an engineering station with SIMATIC NCM PC or STEP 7 In this example SIMATIC NCM PC is installed locally and a download over the network is not necessary e Index 4 is the identification number for internal addressing of the module within the PC station Each configured component of a PC station has a unique index During configuration the index can be set using SIMATIC STEP 7 HW Config SIMATIC NET NCM PC Manual Quick Start 50 C79000 G8976 C 156 01 Quick Start for the OPC Application for PROFIBUS DP 4 2 3 STEP 7 Starting the PC Station Wizard Specifying the Configuration Activity SIMATIC NET Commissioning Wizard Configuration Here you specify the configuration that will be used for this PC Only click the Next button in the Commissioning Wizard dialog when you have completed the configuration SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 51 Quick Start for the OPC Application for PROFIBUS DP 4 2 4 STEP 7 PC Station Wizard Selecting the Editing Mode Changing Settings Activity SIMATIC NCH PC Station Wizard Click the Next button
181. ommunication partner and querying the operating state of the partner Communication with an S7 400 station using the S7 protocol SEND RECEIVE interface is described in detail below SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 61 Quick Start for the OPC Application for Industrial Ethernet 5 2 Quick Start for Industrial Ethernet Communication with OPC Introduction This example illustrates how you can connect an S7 400 programmable controller with a PC station over Industrial Ethernet This section describes the programs used for configuring a PC station for connecting to an S7 400 You will see how symbolic variables in the S7 program are made available in OPC You will also see how to use the OPC Scout program that is supplied with the product for communication with the OPC Server Requirements 5 2 1 If you want to try out the example yourself you require the following e aPC e acommunication module for Industrial Ethernet CP 1613 e the SIMATIC NET CD 07 2001 software e anS7 400 with a CP 443 1 e Industrial Ethernet cabling between the PC module and S7 device For the S7 400 you require an STEP 7 project In the project you specify the hardware configuration and the programs and data blocks and define a symbol table In the example you will expand your existing STEP 7 project by adding a PC station and will configure the connection between the PC station and the S7 400 Hardware and Sof
182. on tools include COML S7 COM PROFIBUS Configuration parameters for the OPC Server that were previously stored in TXT files are now configured in SIMATIC NCM PC STEP 7 and downloaded to the PC station LDB Databases no Longer Required 10 By configuring on a central station and with the option of downloading LDB databases are no longer required for the DP FMS and S7 protocols Existing XDB files can continue to be used they must be imported into the central data management on the PC station using the Station Configuration Editor or PC Station Wizard Note For more detailed information on the difference between the previous methods and working with the software and modules refer to the CD documentation and the Installation Instructions of the SIMATIC NET PC software products m SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C 156 01 2 Configuring SIMATIC PC Stations Communication with PC Applications PC applications that communicate with each other or with other stations such as S7 stations PC stations or operator control and monitoring stations use SIMATIC NET communications modules and software components Before such communication is possible you must first set up the communication services on your PC This chapter explains how to use the tools and utilities with which you set up the PC components for communications tasks 2 1 Tools and Utilities SIMATIC NCM PC Configuration Tool SIM
183. on of programming devices and PCs to PROFIBUS and multipoint capable MPI interface of the SIMATIC S7 For connecting PG PC to PROFIBUS and MPI of the SIMATIC S7 e Communication services PROFIBUS DP master class 1 with SOFTNET DP PROFIBUS DP master class 2 including acyclic DP expansions with SOFTNET DP PROFIBUS DP slave with SOFTNET DP slave PG OP communication 7 communication with SOFTNET S7 5 compatible communi cation SEND RECEIVE on the basis of the FDL in terface with SOFTNET DP or SOFTNET S7 e For PUs PCs with PCI slot PG PC CP 5611 communication processor T petot e Short PCI card for programming device PC with PCI slot Used with STEP 7 STEP 7 Micro Win ProTool ProTool Pro SIMATIC PDM for PG OP communica tion COM PROFIBUS SOFTNET S7 for S7 communication SOFTNET DP for DP OPC servers are supplied with the communication soft ware Short PCI card 9 pin Sub D socket for connection to PROFIBUS under different software pack ages and allows the user to execute programming device functions and PC functions via PROFIBUS and the multipoint interface MPI Only one CP can be operated for each programming device PC Similarly only one protocol PROFIBUS DP S7 communication or FDL can be used for each CP ages support the CP 5611 e STEP 7 V3 2 upwards under Windows 95 and NT
184. on services PG OP communication S7 communication 5 compatible communi cation SEND RECEIVE Can be used in conjunction with CP 1411 ISA CP 1511 PCMCIA Modem Remote Access Service RAS Complete protocol stack as software package OPC servers are supplied with the communication software SOFTNET is available for the following interfaces CP 1411 ISA card CP 1511 PCMCIA card Modem RAS Application Functions With SOFTNET the complete protocol stack is handled by the PC Software for PG OP communication This software allows program ming of the SIMATIC S5 and S7 controllers via Industrial Ethernet in conjunction with STEP 5 STEP 7 Software for S7 communication SIMATIC S7 system compo nents use S7 communication to communicate with each other To allow programming device PC user programs to have access to the SIMATIC S7 M7 system components the S7 programming interface was developed The S7 communications can optionally be based on the ISO protocol or the TCP IP protocol The interface is supplied as a C library or DLL Unlike the 1613 products the performance capability of the SOFTNET packages with this S7 communication offers the following services Administrative services S7 connection management services Variables services e VFD virtual field device services Trace and Mini database 5 compatible communica
185. onfiguration and run time of OPC applications PC Station In this context a PC station means a PC with communications modules and applications The role of this PC might be for example to communicate with SIMATIC S7 devices and perform process control tasks The term run time station is also used to describe such PCs equipped with run time software The PC station is configured for communication with SIMATIC S7 devices in SIMATIC NCM PC STEP 7 The required run time software is available on the PC station after installing APC Advanced PC Configuration STEP 7 Project A STEP 7 Project is created with SIMATIC NCM PC or with STEP 7 NCM It contains the project and configuration data that can be downloaded to S7 stations and PC stations SIMATIC NET NCM PC Manual Quick Start 80 C79000 G8976 C 156 01 AE Pm PG PC TH PROCESS A TITS Overview 4 4 4 r i DOUN J ira ow as Recommended solution for gt PC based control systems Soft Control PLC Numeric Control Robot Control gt Process control systems gt Human Machine Interface HMI gt PROFIBUS systems with a large quantity framework more than 8 stations gt Multi protocol operation gt Use of several CPs in one computer gt Versions with Fiber Optic interface FO CP 5613 PCI P c SIMATIC sma anan SIMATIC CP 5614 PCI You will find software for the PC products under
186. onfiguration data and changing the slave address The extended DP functions also include non cyclic access to the parameters and measured values of a slave e g field devices of the pro cess automation intelligent HMI devices This type of slave must be supplied with extensive parameter data dur ing startup and normal opera tion DS_READ DS_WRITE DS_DATA_TRANSPORT SOFTNET DP slave A DP slave is an I O device that reads input information and supplies output informa tion to the I O The quantity of input and output information depends on the type of device and can be up to 244 byte The slave applications can be implemented on the PC using the functions SET_INPUT and SET_OUTPUT of the slave programming interface Configuration of PROFIBUS DP takes place with the enclosed COM PROFIBUS PC Edition For the slave interface an example GSD file is provided which can be adapted to the relevant application Siemens IK PI 2001 3 363 kesana Functions continued 3 364 44 Siemens IK PI 2001 Connection options for SOFTNET for PROFIBUS Software for PG OP communication No special programming packages are required for the CP 5511 and CP 5611 because the drivers are included in delivery of STEP 7 The SOFTNET PG S5 software is available for programming the SIMATIC S5 with STEP 5 V7 2 or higher Software for S7 communication SOFTNET S7 SIMATIC S7 system compo nents communicate w
187. onic manual on CD ROM German English FMS 5613 Windows NT 4 0 gt 6GK1 713 5FB21 3AA0 2000 Pro Software V2 1 for FMS protocol on CP 5613 CP 5613 FO CP 5614 CP 5614 FO incl PG FDL and FMS OPC server with electronic manual on CD ROM German English PROFIBUS FastConnect gt 6GK1 500 0FC00 RS 485 bus connector Plug 180 PROFIBUS bus terminal 12M gt 6GK1 500 0AA10 PROFIBUS plastic fiber optic gt 6GK1 901 0FB00 0AA0 simplex plug polishing set PROFIBUS plastic fiber optic gt 6GK1 905 6PA10 stripping tool set Connection adapters gt 6ES7 195 1BE00 0XA0 e 50 pieces Manual CP 5613 CP 5614 and SOFTNET for PROFIBUS Including Description of the interfaces FMS DP S7 FDL OPC server configuration tools German 6GK1 971 5DA00 0AA0 e English 6GK1 971 5DA00 0AA1 SIMATIC NET gt 6GK1 704 0AA00 3AA2 Software Update Service For Industrial Ethernet PROFIBUS OPC server Including manuals on CD ROM German English Electronic manuals gt 6GK1 975 1AA00 3AA0 Communication systems protocols products on CD ROM German English vy 1 Download from Internet under http www ad siemens de net dk5613 PGIPC Te Tolet CP 5511 communication processor o f aa PT Overview e For connecting PG PCs and notebooks with PCMCIA slot to PROFIBUS and MPI of the SIMATIC S7 e Communication services PROFIBUS DP master class 1 with SOFTNET
188. ort FreeContact charged only with SIMATIC Card Local time Mo Fr 0 00 to 24 00 Local time Mo Fr 7 00 to 17 00 Phone 49 911 895 7777 Phone 49 180 5050 222 Fax 49 911 895 7001 Fax 49 180 5050 223 GMT 01 00 E mail techsupport ad siemens de GMT 1 00 Europe Africa Nuremberg America Johnson City Asia Australia Singapore Authorization Technical Support and Technical Support and Authorization Authorization Local time Mo Fr 7 00 to 17 00 Local time Mo Fr 8 00 to 19 00 Local time Mo Fr 8 30 to 17 30 Phone 49 911 895 7200 Phone 1 423 461 2522 Phone 65 740 7000 Fax 49 911 895 7201 Fax 1 423 461 2289 Fax 65 740 7001 E mail authorization E mail simatic hotline E mail simatic hotline nbgm siemens de sea siemens com sae siemens com sg GMT 1 00 GMT 5 00 GMT 8 00 The languages spoken on the hotlines are German and English On the authorization hotline French Italian and Spanish are also available SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 77 SIMATIC NET Support and Training Training Center To help you to become familiar with working with SIMATIC S7 PLCs we offer a range of courses Please contact your regional training center or the central training center in D 90327 Nuremberg Tel 49 911 895 3154 Infoline Tel 49 180 523 5611 48 Pfg min Fax 0180 523 5612 Internet http www ad siemens de training E mail AD Training nbgm sieme
189. ort RAM interface D process data through dual Fast commissioning through Can also be used in high D port RAM Plug amp Play and diagnostic temperature industrial envi M Short response time with tools ronments l FastLogic Implementation for motion Process consistent data control applications through from a DP cycle support of the equidistant mode Programming device SIMATIC 7 300 with CP 342 5 DP master E A Transfer mecha nism RS 485 CP 5614 Distributed 1 0 IMATIC ET 200M peene kee eee eee SIMATIC ET 200S G_IK10_deP0110s Fig 3 114 Configuration example with CP 5614 KA Siemens IK PI 2001 amaaa P Connection options for PG PC CP 5614 communications processor Technical specifications Ordering data Baud rates Interfaces connection PROFIBUS DP master PROFIBUS DP slave Supply voltage from PCI Current consumption approx from 5 V DC Power loss approx Perm ambient conditions e Operating temperature Without fan With fan air current 0 5 m s Transport storage temperature e Relative humidity max Design e Module format e Dimensions W x H in mm e Weight approx e Space required Performance data Single protocol mode e No of connectable DP slaves max e Data area of slave interface input data output data diagnostics data e No of parallel FDL tasks to be processed max
190. osensing 10 100 Mbit s D Industrial Software for TF protocol TF 1613 e The technological functions interface offers access to the MAP 3 0 open and well proven automation protocol on Ethernet The Technolog ical Functions correspond in functionality to the interna tional MMS services in ac cordance with ISO IS 9506 MMS TF services e Variable services Domain services Program invocation services e General services for virtual devices VMD support service e Services of TF link manage ment environment and general management services Further details are available in the Internet http www ad siemens de netik info Operation of large network configurations with one card due to large number of con nections e Can be used for redundant communication OPC as common interface aay Siemens IKPI October 2000 AETA Industrial Ethernet System interfacing for PG PC CP 1613 communication processor Industrial E Technical specifications E Ordering data Order No Transmission rate 10 100 Mbit s CP 1613 gt 6GK1 161 3AA00 PCI card for connection to Interf nteriaces l Industrial Ethernet 10 100 Mbit s e Connection to Industrial Ethernet 15 pin Sub D socket with AUI ITP and RJ45 port 10 100 Mbit s autom switching between AUI and twisted pair S7 1613 Windows NT 4 0 2000 Pro 6GK1 716 1CB21 3AA0 10BaseT 100BaseTX RJ45 V2 1 o a o Software for S7 communica
191. ow ing compilers can therefore be used in conjunction with the SIMATIC NET products Microsoft Visual C C V6 0 e Microsoft Visual Basic V6 0 For Borland programming interfaces e g DELPHI part ner solutions of AIXO are available For solutions for other operat ing systems see the Develop ment Kit DK 5613 The DK 5613 can be found in the Internet http www ad siemens de net dk5613 E Configuration For all packages mentioned The complete configuration of Configuration of PROFIBUS above the configuration tools are included in the scope of supply the S7 communication is per formed using STEP 7 V5 0 SP3 and higher The configu rations generated for the PCs using STEP 7 are stored in files which are subsequently transferred to the individual PCs DP and FMS takes place with the enclosed COM PROFIBUS PC Edition H Diagnostics Extensive diagnostic tools are Therefore a PROFIBUS available for installation commissioning and opera tion for the module itself and for the PROFIBUS network network can be started up quickly and easily with a CP 5613 ae Siemens IKPI October 2000 Js A 5 f Designed for Industry Fastest possible access to process data via Dual Port RAM e Short response time with FastLogic Process consistent data from a DP cycle Technical specifications Baud Rates 9 6 Kbit s to 12 Mbit s Interfaces e Connection to PROF
192. package Advanced PC Configuration at Diagnosis Extensive diagnostic tools are Therefore a PROFIBUS net available for installation commissioning and opera tion for the module itself and for the PROFIBUS network work can be started up quickly and easily with a CP 5613 Siemens IK PI 2001 H 5 Connection options for PG PC CP 5613 communications processor Designed for Industry Fastest possible access to process data through dual port RAM e Short response time with FastLogic e Process consistent data from a DP cycle Technical specifications Baud rates 9 6 kbit s to 12 Mbit s Interfaces Connection to PROFIBUS 9 pin Sub D socket Supply voltage from PCI 5 V DC 5 Power consumption from 5 V 1 3A Power loss 6 5 W Perm ambient conditions e Operating temperature Without fan With fan air current 0 5 m s Transport storage temperature 5 C to 40 C 5 C to 60 C 40 C to 70 C e Relative humidity max 95 at 25 C Design e Module format PCI card e Dimensions W x H in mm 107 x 168 e Weight approx 250g e Space required 1 x PCI slot Performance data Single protocol mode No of connectable DP slaves max 122 e No of parallel FDL tasks o be processed max 120 No of PG OP and S7 connections max 501 No of FMS connections max 40 2 1 For credit 1 PDU size lt 480 byte 2 For credit 1 Ordering data Order No
193. pin Sub D socket 5 V DC 5 0 5A 2 0 W 5 C to 40 C 20 C to 60 C 95 at 25 C PCI card 102 x 130 100 g 1 x PCI slot EET Ikl Siemens IK PI October 2000 O i TE bilities for Easy installation and com missioning CP 5611 communication processor gt PCI card for connecting a PG or PC to PROFIBUS CP 5611 MPI gt Consists of PCI card CP 5611 and MPI cable 5 m SOFTNET S7 Windows 98 NT4 0 gt 2000 Pro Software V5 3 for S7 communication incl FDL and S7 OPC server with electronic manual on CD ROM SOFTNET DP Windows 98 NT 4 0 gt 2000 Pro Software V5 3 for DP protocol incl FDL and DP OPC server with electronic manual on CD ROM SOFTNET DP slave Windows 98 NT 4 0 2000 Pro Software V1 2 for DP slave interface with electronic manual on CD ROM PROFIBUS FastConnect gt RS 485 bus connector Plug 180 With 180 cable outlet PROFIBUS bus terminal 12M gt Bus terminal for connecting PROFIBUS stations up to 12 Mbit s with connecting cable Manual CP 5613 CP 5614 and SOFTNET for PROFIBUS Including Description of the interfaces FMS DP S7 FDL OPC server configuration tools e German e English SIMATIC NET gt Software Update Service For Industrial Ethernet PROFIBUS OPC server including manuals on CD ROM German English vy Electronic manuals gt Communication systems protocols products on CD ROM German English g
194. ptical PROFIBUS 9 pin Sub D socket for con necting to PROFIBUS Connection for external power supply This means data transmission on the optical line is not inter rupted when the PC is switched off Parallel operation of up to 4 CPs e The software can switch assignment of master and slave to the optical and electrical interface The module is installed using standard PCI mechanisms plug amp play PROFIBUS with integrated interface and OBT through Plastic and PCF FOCs with simplex plugs It is connected to the electri cal PROFIBUS through e Plastic and PCF fiber optic cable with simplex plugs to an OBT E Functions PROFIBUS DP Event filter mechanism Signaling by interrupt for 3 354 73 Siemens IK PI 2001 O Access to process data The CP 5614 is operated as a PROFIBUS DP master and slave module which holds the process image input output and diagnostic data in the dual port RAM The high per formance data exchange with the PROFIBUS slaves is han dled independently by the CP 5614 FO hardware The user has direct access to the dual port RAM The process data of the slaves are always consistent i e the user gets the data from one and the same DP cycle Parallel operation of DP 5613 DP master and DP Base DP master DP slave is not possible The user receives up to date data through two access mechanisms Cyclic polling of the DP slaves higher load on host CPU
195. ration The communications parame The following demo programs ters canbe completely config are supplied as standard ured using the tools in the For custom interface software which is already in C installed i For Automation Interface with Visual Basic Designed for Industry Simple use of different net e Easy integration in the sys Easy to handle and cost works and protocols through tem environment and office effective because the OPC standard interface applications via C and servers are supplied with the Reduced training and learn Visual Basic interface communication software ing requirements Short programming times for applications 3 279 Siemens IK PI October 2000 J anasa O 3 Connection possibilities for PG PC OPC server Technical specifications OPC server Programming Access to Interfaces Protocols Availability Open and standardized e Can be used with different manufacturers systems Variable item groups One set of variables enabling processing of large data volumes in a short time Custom Interface C OPC is therefore powerful Automation Interface VB Excel Access Delphi etc therefore easy to use Graphics with OCX allowing configuration instead of programming DP protocol S7 communication FMS protocol S5 compatible communication SEND RECEIVE Windows NT 4 0 2000 Professional is automatica
196. ro Windows NT 4 0 or Windows 98 Situation Windows 98 is no longer supported PG operation under Windows 2000 Pro or Windows NT 4 0 remains possible and is unchanged Steps to take Under Windows 98 use the SIMATIC NET CD 05 2000 SOFTNET PG up to version 3 3 with Service Pack 2 for Windows 2000 Pro Windows NT 4 0 Windows Me or Windows 98 Situation Windows Me and Windows 98 are no longer supported PG operation under Windows 2000 Pro or Windows NT 4 0 remains possible and is unchanged Steps to take Under Windows Me or Windows 98 use the SIMATIC NET CD 05 2000 SIMATIC NET PC Software CD 07 2001 94 79220 A5822 X 01 7419 SIMATIC NET PC Software CD 07 2001 SOFTNET S7 up to version 3 3 for Windows 2000 Pro Windows NT 4 0 or Windows 98 Situation Windows 98 is no longer supported An S7 configuration created with the COML S7 program cannot be used Steps to take Under Windows 98 use the SIMATIC NET CD 05 2000 A configuration created with the COML S7 program must be recreated with SIMATIC NCM PC V5 1 Service Pack 2 or STEP 7 Version 5 1 Service Pack 2 or higher If the configuration was already created with STEP 7 XDB this STEP 7 project can continue to be used You only need to download the configuration to the CP PC station from STEP 7 Version 5 1 Service Pack 2 or higher SIMATIC NET PC Software CD 07 2001 79220 A5822 X 01 7419 95 SIMATIC NET PC Software CD 07 2001 4 4 PROFIBUS Effects on O
197. s Aktiengesellschaft G79000 G8976 C156 01 SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C 156 01 This manual supports you and helps you to make efficient use of the communications functions of your PC applications in conjunction with the SIMATIC NET modules supplements the OPC documentation on the SIMATIC NET PC Windows CD The descriptions are structured as shown below Manual Quick Start c SIMATIC NCM PC 4 ue on PC Configuring tools You will find tools for every situation here ERR of NCM OPC from A to Z EE GeeIdOne e Configuring the description OPC Server e OPC tools and e OPC application with communication over Ethernet a Quick Starts S g e OPC application with access to a DP master system SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 Active X controls OPC application with communication over Ethernet OPC application with access to a DP master system PROF Inet applications This manual Additional Information This manual is also part of the documentation packages for NCM S7 for PROFIBUS and Indusirial Ethernet Tip This symbol appears in the margin to draw your attention to useful tips Additional Information on SIMATIC S7 and STEP 7 The following documentation contains additional information about the STEP 7 standard software of the SIMATIC programmable controllers and can be obtained from your local
198. software is not possible e DP master class 2 In addition to DP master class 1 services the CP 5613 FO also offers DP master class 2 services in connection with the DP programming interface according to IEC 61 158 EN 50170 Devices of this type programming con figuration or operating devices are used for commis sioning configuring the DP system or system operation in normal operation diagnos tics The DP programming interface provides the follow ing services Master diagnostics Slave diagnostics Read inputs outputs of a slave Reading configuration data and Changing the slave address The extended DP functions also include non cyclic access to the parameters and measured values of a slave e g field devices of the pro cess automation intelligent HMI devices This type of slave must be supplied with extensive parameter data dur ing startup and normal opera tion DS_READ DS_WRITE DS_DATA_TRANSPORT Software for PG OP communication This software enables pro gramming of the SIMATIC S5 S7 controllers through PROFIBUS in con nection with STEP 5 STEP 7 The PG OP communication for the CP 5613 FO is already available after installing the CP 5613 FO DP Base No additional software pack age is needed 5 compatible communica tion SEND RECEIVE based on the FDL interface SEND RECEIVE FDL inter face is already available after installation of the CP 5613 FO DP Base
199. st assign a name for the station by clicking the Station button The name must match the name you assigned to the PC station when you configured the communications with SIMATIC NCM PC 2 If you want the PC station to be accessible on the network select the station by clicking the Host button 3 Create the individual components for your PC station by clicking the Add button The status display constantly informs you whether the component you have created matches the current hardware configuration and whether it matches any configuration that has already been downloaded Note You will find more information on the meaning of the display boxes and the buttons in the integrated help system Importing an XDB File The communication configuration data are either downloaded directly to the PC station or imported using an XDB file see Section 2 4 When required the XDB file can be imported using the relevant button in the Station Configuration Editor You can only import an XDB file when the configuration is an exact match Checking the Accessibility of the Module Ring Function Once you have finished configuring you can check the accessibility of the modules by clicking the Ring button If the module supports this function you will see an indicator respond on the module SIMATIC NET NCM PC Manual Quick Start 36 C79000 G8976 C 156 01 Configuring SIMATIC PC Stations 2 7 2 Diagnostics Tab
200. t connection to the op the host CPU ronments E tical PROFIBUS through in Easy portability to other op Flexible application through 4 tegrated FOC interface erating systems through a switchable assignment of Fastest possible access to dual port RAM interface optical and electrical inter process data through dual Implementation of motion face to master and slave i port RAM control applications through Short response time with support of the equidistant FastLogic mode Process consistent data from a DP cycle Programming device i H Le with CP 5613 FO SIMATIC S7 300 with CP 342 5 FO i ml I i iy E H y E E Transfer San FO mecha Switchable nism RS ee DP Master CP 5614 FO MEE Distributed I O eee coe cee sss eee I SIMATIC ET 200S G_IK10_deP0109s Fig 3 115 Configuration example with CP 5614 FO Siemens IK PI 2001 i 3 Technical specifications Baud rates Basic interface setting PROFIBUS master PROFIBUS slave Interfaces switchable through software call PROFIBUS master PROFIBUS slave External power supply optional hrough standard external power supply Supply voltage from PCI Current consumption from 5 VDC e from 12 V DC Power loss Supply voltage optional external power supply e Current consumption e Power loss Perm ambient conditions Operating temperature Without fan With fan air current 0 5 m s
201. tage from PCI Current consumption efrom 5VDC e from 12 V DC Power loss Supply voltage optional external power supply e Current consumption e Power loss Perm ambient conditions e Operating temperature without fan with fan air current 0 5 m s Transport storage temperature e Relative humidity max Design e Module format e Dimensions W x H in mm e Weight approx e Space required Performance data Single protocol mode Number of connectable DP slaves max e No of parallel FDL tasks to be processed max No of PG OP and S7 connections max No of FMS connections max 1 for credit 1 PDU size lt 480 bytes 2 for credit 1 Connection possibilities for PG PC CP 5613 FO communication processor 9 6 Kbit s to 12 Mbit s 2 x Duplex socket FO Low voltage socket 3 5 mm 1 3 mm a 5 V DC 5 12 V DC 5 14A 0 3 A 7W 9 12VDC O4A 3 6 4 8 W 5 C to 40 C 5 C to 60 C 40 C to 70 C 95 at 25 C PCI card 107 x 168 250g 1 x PCI slot 122 120 501 40 2 a 2 2 1 Siemens IK PI October 2000 E Ordering data Order No CP 5613 FO communication gt 6GK1 561 3FA00 processor PCI card for connection to PROFIBUS incl Windows NT 4 0 2000 Pro drivers DP RAM interface for DP master incl PG and FDL configuration software with electronic manual on CD ROM Development Kit 1 DK 5613 Software Develop
202. tc Programming interface through C Library The programming interfaces for existing applications are implemented as a Dynamic Link Library DLL The follow ing compilers can therefore be used in conjunction with the SIMATIC NET products e Microsoft Visual C C V6 0 e Microsoft Visual Basic V6 0 For Borland programming interfaces e DELPHI part ner solutions of the AIXO Co are available For solutions for other operat ing systems see the develop ment kit DK 5613 The DK 5613 can be found in the Internet at http www siemens de simatic net dk5613 Connection options for PG PC CP 5614 FO communications processor S Configuration e Configuration of S7 commu The configuring tool NCM PC is a component of nication protocols NCM PC is included in Advanced PC Configuration S5 compatible communica delivery of the PROFIBUS tion DP protocol DP DPV1 software package DPV2 and FMS protocol is executed in STEP 7 NCM PC V5 1 SP2 or higher Diagnosis Extensive diagnostic tools are Therefore a PROFIBUS available for installation network can be started up commissioning and opera quickly and easily with a tion for the module itself and CP 5614 for the PROFIBUS network Designed for Industry Only 1 slot is required for a Higher computing perfor Can also be used in high master and slave mance in the PC by relieving temperature industrial envi E Direc
203. that the CP 1613 accesses driver or Windows 2000 Pro To permit a large number of the physical RAM of the host driver connections and high commu The transfer rate is detected nication integrity 16 Mbytes of and automatically switched memory are provided over autosensing E Functions User interfaces Programming interface Software for OPC interface via C library PG OP communication j j The programming interfaces This software permits pro f Meena T e n for the protocols S7 commun gramming of SIMATIC S5 package can be used as a ciation PG OP communica and S7 PLCs via Industrial standard programming inter tion S5 compatible communi Ethernet in combination with A face for the protocols 7 cation and TF protocol for STEP 5 STEP 7 automation communication and S5 existing applications are systems I compatible communication to implemented as a Dynamic It is contained in all CP 1613 connect automation applica Link Library DLL software packages tions to OPC capable The following compilers can Windows applications therefore be used in conjunc Office HMI systems etc tion with the SIMATIC NET products e Microsoft Visual C C V6 0 e Microsoft Visual Basic V6 0 4 116 4 amp Siemens IK PI October 2000 O p po Industrial Ethernet system interfacing for PG PC CP 1613 communication processor Functions continued Configuration Designed for Industry Software for S7 communication S7 1613 or
204. the SIMATIC NCM PC configuration tool You can call it up either directly or start it when using the Commissioning Wizard The following graphic shows the steps required and which tools to use When you use the wizards you are guided through these steps automatically and can assume that the configuration data created in SIMATIC NCM PC are consistent with the PC configuration Use the Commissioning Wizard Use the Creating PC components with PC Station Wizard the Station Configuration Editor Configuring communication services with SIMATIC NCM PC Creating connections Setting up DP master systems Downloading configuration data to the PC station PC station Utilities for commissioning operation e Configuration Console for settings and diagnostics OPC Scout for displaying communication variables and diagnostics SIMATIC NET NCM PC Manual Quick Start 12 C79000 G8976 C 156 01 Configuring SIMATIC PC Stations Further Utilities From the graphic you can see that there are other utilities available for example for using the OPC Server interface These utilities will be pointed out or described in greater detail where applicable e Configuration Console A utility with which you can display the structure of a PC station in much the same way as in the Windows Explorer The interactive options are Module diagnostics Setting the operating mode Configuration for specific situations e OPC
205. the new tool with which you can commission a PC station as part of an industrial communication network SIMATIC NET supports the option of using Advanced PC Configuration on a central engineering station to configure PC stations in the same way as programmable controllers A networked PC with the SIMATIC NCM PC V5 1 Service Pack 2 or STEP 7 V5 1 Service Pack 2 program is used as the engineering station Features Using Advanced PC Configuration means certain changes in the way you configure in your project e All settings are made and downloaded to the PC station with one tool during configuration This tool is the SIMATIC NCM PC V5 1 Service Pack 2 or STEP 7 version 5 1 Service Pack 2 program or higher e Properties that were previously configured using the Set PG PC Interface program are now part of the configuration and are downloaded to the PC station These include for example the station address and the bus parameters Creating several databases is no longer necessary e Properties that were previously specified in various configuration programs are now configured in SIMATIC NCM PC V5 1 Service Pack 2 or STEP 7 Version 5 1 Service Pack 2 or higher Examples of such configuration tools include COML S7 COM PROFIBUS e Configuration parameters for the OPC Server that were previously stored in TXT files are now configured in SIMATIC NCM PC V5 1 Service Pack 2 or STEP 7 Version 5 1 Service Pack 2 and downloaded to the PC station
206. tings for the OPC servers that ship with the communication software are also made in the Configuration Console SIMATIC NCM PC and PC Station Wizard With SIMATIC NCM PC V5 1 Service Pack 2 a new configuration tool for STEP 7 compatible PC configuration is available Station Configuration Editor The Station Configuration Editor is the user interface of the Station Manager this allows you access to the component management of the PC station The following Chapter LEERER MERKER also contains information on these tools and other related utilities SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 Introduction and Notes on Switching to Advanced PC Configuration Features Comparison with Previous Products The new features of the SIMATIC NET software involve several changes to the previous configuration procedures and these are summarized below All settings are made with one tool during configuration and downloaded completely to the PC station This tool is SIMATIC NCM PC or STEP 7 Properties that were previously configured using the Set PG PC Interface program are now part of the configuration and are downloaded to the PC station These include for example the station address and the bus parameters It is no longer necessary to create several databases Properties that were previously specified in various configuration programs are now configured in SIMATIC NCM PC STEP 7 Examples of such configurati
207. tion 002 0000 4 2 9 STEP 7 Commissioning Wizard Specifying the Use of Symbol Files 4 2 10 OPC Scout Establishing a Connection to the OPC Server 4 2 11 OPC Scout Inserting a Group and Variables 000005 4 2 12 OPC Scout Displaying and Modifying Values of Variables 5 Quick Start for the OPC Application for Industrial Ethernet 5 1 Example of an Industrial Ethernet Configuration 5 2 Quick Start for Industrial Ethernet Communication with OPC 5 2 1 Hardware and Software Installation 0 cece eee eee 5 2 2 Configuring the PC Station 0 0c SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 Contents 5 2 3 STEP 7 Starting the PC Station Wizard 0 00 c cece eee 65 5 2 4 STEP 7 PC Station Wizard Selecting the Editing Mode 66 5 2 5 STEP 7 PC Station Wizard Opening the Project 67 5 2 6 STEP 7 PC Station Wizard Changing Settings 68 5 2 7 STEP 7 NetPro i anonn neee Ree penta enna panei 69 5 2 8 STEP 7 NetPro Downloading the Configuration 70 5 2 9 STEP 7 Commissioning Wizard 000 eee eee eee 70 5 2 10 Symbol File Configurator 0 0 eee 71 5 2 11 SIMATIC NET Commissioning Wizard 00 cee eee 72 5 2 12 OPC Scout Establishing a Connection to the OPC Serv
208. tion SEND RECEIVE This layer 4 based interface ISO transport or TCP IP with RFC 1006 is used for commu nication between PG PC and SIMATIC S5 PG PC and SIMATIC S7 PG PC and PG PC S5 compatible communica tion SEND RECEIVE pro vides the following services Management services Link connection service Data transfer services architecture depends on the network extension and or workload of the PC used User interfaces OPC interface The OPC server contained in the respective software pack age can be used as a stan dard programming interface for the protocols S7 communi cation and S5 compatible communication to connect automation applications to OPC capable Windows applications Office HMI systems etc Programming interface via C library The programming interfaces for the protocols S7 communi cation PG OP communica tion S5 compatible communi cation and TF protocol for existing applications are implemented as a Dynamic Link Library DLL The following compilers can therefore be used in conjunc tion with the SIMATIC NET products e Microsoft Visual C C V6 0 e Microsoft Visual Basic V6 0 a ac Siemens IKPI October 2000 MAPT Industrial Ethernet System interfacing for PG PC SOFTNET for Industrial Ethernet Industrial Configuration For the relevant packages the necessary configuring tools are contained in the scope of supply Designed for I
209. tion Supply voltage 5V DC 5 i 5 compatible communication 12V DE 25 SEND RECEIVE and PG OP Current consumption communication incl S7 OPC server for CP 1613 with electronic e from 5 V DC 600 mA manual on CD ROM e from 12V DC 500 mA German English Power loss 4w TF 1613 Windows NT 4 0 2000 Pro gt 6GK1 716 1TB21 3AA0 Perm ambient conditions v2 1 z Operating temperature 5 C to 40 C Software for TF protocol 5 5 S5 compatible communication Transportation storage temperature 20 C to 60 C PG OP communication e Relative humidity max 95 at 25 C for CP 1613 incl OPC server for Daaa aaa O S5 compatible communication Construction with electronic manual e Module format Short AT format on CD ROM e Dimensions W x D in mm 107 x 167 German English Weight approx 200 g PG 1613 Windows NT 4 0 2000 Pro gt 6GK1 716 1PB21 3AA0 e Space requirements 1 x PCI slot V2 4 Single protocol mode Software for PG OP communication performance data for CP 1613 S7 and PG OP communication Oca manual 4 No of operable connections G Enalish i ISO max 120 erman Englis TCP IP max 120 S7 REDCONNECT Windows NT 4 0 6GK1 716 0HB13 3AA0 S5 compatible communication V1 3 SEND RECEIVE f Software for fail safe e No of operable connections S7 communication via redundant net ISO max 120 works for CP 1413 CP 5412 A2 TCP IP max 120 CP 1613 incl S7 OPC server OT with electronic manual on CD ROM German English S7 REDCONNECT
210. tion of up to 4 CPs The module is installed via PCI standard mechanisms plug amp play cal PROFIBUS by bus connector and PROFI BUS bus cable or e bus terminal e g 12M bus terminal and PROFIBUS bus cable It is connected to the optical PROFIBUS by bus cable with 2 bus con nectors or 830 1T PROFIBUS connect ing cable to an OLM PROFIBUS with integrated interface and OBT by e bus cable with 2 bus con nectors or 830 1T PROFIBUS connect ing cable to an optical bus terminal OBT for PROFIBUS Direct connection to the opti cal PROFIBUS with integrated interface by CP 5614 FO E Functions PROFIBUS DP Parallel operation of DP 5613 Both alternatives can be com Access to process data The CP 5614 is operated as a PROFIBUS DP master and DP slave module which holds the process image input output and diagnostic data in the Dual Port RAM The high per formance data exchange with the PROFIBUS slaves is han dled independently by the CP 5614 FO hardware The user has direct access to the Dual Port RAM The process data of the slaves are always consistent i e the user gets the data from one and the same DP cycle DP master and DP Base DP master DP slave is not possible Event filter mechanism The user receives up to date data via two access mecha nisms e Cyclic polling of the DP slaves higher load on host CPU e Signalling by new kind of event filter mode in the e
211. tton The last dialog box of the Commissioning Wizard appears Click the Finish button to complete your work with the wizard SIMATIC NET NCM PC Manual Quick Start 72 C79000 G8976 C 156 01 Quick Start for the OPC Application for Industrial Ethernet 5 2 12 OPC Scout Establishing a Connection to the OPC Server The OPC Scout as Client for Commissioning and Testing You can now access the data objects of the S7 station with any OPC client The OPC Scout ships with this product as the tool for commissioning and testing Follow the steps outlined below to read the inputs and set the outputs using the OPC Scout Activity 1 Start the OPC Scout in the Start menu Start gt SIMATIC gt SIMATIC NET gt Industrial Ethernet gt CP1613 gt OPC Scout Servers and groups Serverls Local Servers 2 CFG SimaticNET WSS 2 OPC SimaticNET DP S Br Remote Server s Sy Add Remote Servers s SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 73 Quick Start for the OPC Application for Industrial Ethernet 5 2 13 OPC Scout Inserting a Group and Variables Organizing Process Variables The process variables of the OPC Server known as OPC items are assigned to groups You therefore require an OPC group before you can insert OPC variables Follow the steps outlined below to create a group and add items to it Activity BejAdd Group Group Properties
212. tware Installation Installing the Software 62 Activity Turn on the PC and start Windows 2 Insert the SIMATIC NET 07 2001 CD If the installation program does not start the CD automatically start the Setup exe program on the CD 3 Follow the on screen instructions of the installation program 4 Once you have completed the installation the Commissioning Wizard starts automatically SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C 156 01 Quick Start for the OPC Application for Industrial Ethernet Installing the CP 1613 Activity 1 Shut down the PC and turn it off Disconnect the power cable Read the instructions for installing cards in the manufacturer s instructions for your PC Insert the CP 1613 module in a PCI slot 5 Reassemble the PC as described in the instructions of the PC manufacturer and reconnect the power cable Attaching to the Network Activity 1 Connect the Ethernet cable to the CP 1613 2 Connect the S7 400 device to the network cable 5 2 2 Configuring the PC Station Basic Configuration of the Installed Module Activity 1 The welcome page of the Commissioning Wizard opens Click Next SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C 156 01 63 Quick Start for the OPC Application for Industrial Ethernet SIMATIC NET Commissioning Wizard x PC Station Configuration 2 6 bo Here you decide which
213. twork How to Start the Station Configuration Editor The Station Configuration Editor is always available and started on the PC station on which you have installed the PC CD You can bring it to the foreground by clicking the icon shown here in the taskbar of the Windows desktop SIMATIC NET NCM PC Manual Quick Start 34 C79000 G8976 C 156 01 Configuring SIMATIC PC Stations 2 7 1 Managing Components Components Tab I Station Configuration Editor ONLINE CP Name CP5611 AppName Application Notice The components in the configuration list you can edit here must be entered in exactly the same order as in the component image you created in SIMATIC NCM PC with HW Config If the configurations differ the configuration data that you download to the PC station from SIMATIC NCM PC will not be adopted correctly SIMATIC NET NCM PC Manual Quick Start C79000 G8976 C156 01 35 Configuring SIMATIC PC Stations Creating a Component Configuration e Automatic configuration using wizards In the simplest situation you use the Commissioning Wizard and the PC Station Wizard to configure your PC station In this case the component configuration is acquired automatically You then simply call the configuration editor described here to check the configuration or to run diagnostic checks e Controlled configuration 1 Fir
214. ule is installed using standard PCI mechanisms plug amp play cal PROFIBUS through Bus connector and PROFIBUS bus cable or e Bus terminal e g 12M bus terminal and PROFIBUS bus cable It is connected to the optical PROFIBUS through e Bus cable with 2 bus connectors or 830 1T PROFIBUS connecting cable to an OLM PROFIBUS with integrated interface and OBT through Bus cable with 2 bus connectors or 830 1T PROFIBUS connecting cable to an optical bus terminal OBT for PROFIBUS Direct connection to the opti cal PROFIBUS with integrated interface through CP 5614 FO E Functions PROFIBUS DP Parallel operation of DP 5613 Both alternatives can be com Access to process data The CP 5614 is operated as a PROFIBUS DP master and DP slave module which holds the process image input output and diagnostic data in the dual port RAM The high per formance data exchange with the PROFIBUS slaves is han dled independently by the CP 5614 FO hardware The user has direct access to the dual port RAM The process data of the slaves are always consistent i e the user gets the data from one and the same DP cycle DP master and DP Base DP master DP slave is not possi ble Event filter mechanism The user receives up to date data through two access mechanisms e Cyclic polling of the DP slaves higher load on host CPU e Signaling by new kind of event filter mode in the event of changes
215. ustrial One adapter is designed for in any programming Ethernet except UNIX the connecting to RJ45 another device PC withafreePCMCIA CP 1511 can be used e g in adapter offers an interface for type II slot aprogramming device 720 for industrial twisted pair remote programming PG OP communication The CP 1511 can be operated in any computer with a slot complying with the PCMCIA 2 0 standard E Design PCMCIA card type Il There are no jumpers on the 15 pin Sub D socket module it can be set com for industrial twisted pair pletely by software E Application The CP 1511 offers the follow Level 4 and level 7 In addition the protocols for ing accesses In conjunction with the Industrial Ethernet provided Layer 2 SOFTNET packages for by the operating system are Interfacing for PC networks Industrial Ethernet the also supported in an industrial environment CP 1511 offers low cost ac The CP 1511 is not supported cess to Industrial Ethernet under the Windows 2000 Pro e g to the SIMATIC S5 S7 operating system 4 123 Siemens IK PI October 2000 p Industrial Industrial Ethernet system interfacing for PG PC CP 1511 communication processor Configurations Designed for Industry A Production Level be PC with CP 1613 and WinCC q T 7 400 iil i ITP Standard Cable 9 15 Fig 4 61 e Universal connection possi bilities ITP or RJ45 Optimize
216. vanced PC Configuration E Functions NCM PC A configuration wizard inte Note continued NCM PC replaces the previ ous PC configuration tools COML S7 and COM PROFI BUS PC Edition In future PC configuration can be carried out in either STEP 7 or NCM PC version V5 1 SP2 or higher Both tools offer the same look amp feel and create the same database This ensures consistent configura tion of protocols for S5 com patible communication S7 communication DP protocols and FMS protocols No further need for multiple entries and data consistency is automati cally ensured Adauga PS buuiiyuration Industrial Ethernet i grated in NCM PC also en sures user prompted configuration of the PC sta tion With NCM PC and STEP 7 from Version V5 1 SP2 a PC can be configured in the same way as a SIMATIC S7 station and loaded through the network This applies both to the local station on which NCM PC or STEP 7 is installed and the remote sta tion that is operated through the network NCM PC does not contain a conversion for LDBs that were cre ated with COM PROFBUS or COML S7 In this case these must be re configured For further information on Advanced PC Configuration and the previous versions of PC Windows software products please visit us in the Internet at ENE INTERNET http www siemens de simatic net ik info EL 5 it with STEP 7 or NCM PC EL Engineering Statio
217. ve diagnostics reading the inputs and outputs of a slave reading configuration data and changing the slave address The extended DP functions also include non cyclic access to the parame ters and measured values of a slave e g field devices of the process automation intelli gent HMI devices This type of slave must be supplied with extensive parameter data during startup and normal operation DS_READ DS_WRITE DS_DATA_TRANSPORT SOFTNET DP slave A DP slave is an I O device that reads input information and supplies output informa tion to the I O The quantity of input and output information depends on the type of device and can be up to 244 bytes The slave applications can be implemented on the PC using the functions SET_INPUT and SET_OUTPUT of the slave programming interface Configuration of PROFIBUS DP takes place with the enclosed COM PROFIBUS PC Edition For the slave interface an example GSD file is provided which can be adapted to the relevant application aa Siemens IK PI October 2000 MIKUEE fT E mji J Functions continued Connection possibilities for PG PC SOFTNET for PROFIBUS Software for PG OP communication No special programming packages are required for the CP 5511 and CP 5611 because the drivers are con tained in the scope of supply of STEP 7 Programming with STEP 5 is not possible with the CP 5511 CP 5611 Software for S7 communication
218. vent of changes in the input data of a slave minimum load on host CPU bined Optimum utilization of the PC is therefore possible for the application in question The new event filter mecha nism can also be used for e Signalling by Interrupt for diagnostic messages from slaves In equidistant mode signal ling by interrupt Start DP cycle End of cyclic data exchange with the DP slaves from hardware version 3 in preparation Equidistant mode settable as of STEP 7 V5 1 TET Siemens IKPI October 2000 MIH ET me aR 3 m Functions continued FastLogic rapid shutdown FastLogic means that the CP 5614 can react automati cally to up to 4 plant states A fast response time and inde pendence of the host applica tion is achieved here e g fast switch off of devices DP programming interface The DP programming inter faces of the CP 5613 and CP 5614 are identical The DP programming inter face of the CP 5614 has the following functional scope DP slave DP master class 1 Including acyclic DP exten sions DP master class 2 in preparation incl non cyclic DP expansions Access to the process data is directly through the Dual Port RAM The Dual Port RAM interface not only offers fast access as a DP master slave but also a basis for portability to other operating system environments e g VXWorks QNX RMOS A DP master and a DP slave library DP_BASE DLL or
219. ware for PROFIBUS FMS interface FMS 5613 The user interface is compatible with software FMS 5412 With the FMS programming interface Al compatible PCs can exchange data with FMS capable controllers e g S5 S7 and field devices of other manufacturers The use of the FMS protocol ensures open communication The following services are available via the FMS inter face e Administrative services CRL management services FMS connection manage ment services Object directory manage ment services for clients and server e Variable services for clients and server read write infor mation report e Server functionality e VFD virtual field device services for clients and server Bus access information ser vices live list e Trace and mini database User interfaces OPC interface The OPC server contained in the respective software pack age can be used as a stan dard programming interface for the protocols PROFIBUS DP S7 communication and PROFIBUS FMS to connect automation applications to OPC capable Windows appli cations Office HMI systems etc Programming interface via C Library The programming interfaces for existing applications are implemented as a Dynamic Link Library DLL The follow ing compilers can therefore be used in conjunction with the SIMATIC NET products Microsoft Visual C C V6 0 e Microsoft Visual Basic V6 0 For Borland programming interfac
220. with Advanced PC Configuration Description Configuration with Advanced PC Configuration means configuring with the tools of the SIMATIC NET CD Version 07 2001 or higher Central Data Management for all Components The configuration information for all protocols modules and for OPC is all maintained in a central data management system The configuration data can be transferred to the central data management in different ways The following graphic illustrates an example of importing an XDB database created by SIMATIC NCM PC V5 1 Service Pack 2 STEP 7 Version 5 1 Service Pack 2 OPC DP OPC FMS F l OPC S7 adapter _ adapter adapter IT ASAR SURE Ee Sa SIMATIC NET PC Software CD 07 2001 79220 A5822 X 01 7419 91 SIMATIC NET PC Software CD 07 2001 4 2 4 Continued Use of Previous Configurations Continued Use of Databases and Configuration Tools 92 The following table shows an overview of the previous database types and the corresponding configurations and indicates whether continued use is possible Protocol Database Configuration Continued Use we Tool COM Continued use not possible the PROFIBUS configuration must be recreated with SIMATIC NCM PC V5 1 Service Pack 2 or STEP 7 Version 5 1 Service Pack 2 or higher Text Editor Continued use not possible the configuration must be recreated with SIMATIC NCM PC V5 1 Service Pack 2 or STEP 7 Version 5 1 Service Pack 2 or higher COM Continued use

Download Pdf Manuals