Home

Information LAN/USB Interface

image

Contents

1. layout via your PC Start the program by double clicking the icon LI USB Fahrpult on your desktop E a LI USB Fahrpult Once the program has been started the program LI USB Server is started automatically at the same time you will see the program window Please refer to the following page for more information a LI USB Fahrregler E x Beth n Click here and enter the desired locomotive address via your 1003 ers gt keyboard 0 28 u m Hf Use the slider for speed control The speed step and speed step mode are shown above the a mo e slider F A N Use these buttons to activate or deactivate functions Activated Ale F18 F13 F20 functions are highlighted F21 F22 F23 F24 This button triggers a STOP for E F ES all locomotives Click and the c locomotives will move again ro Digital Licht bius STOP These buttons determine the P direction of travel Lenz ELEKTRONIK GMBH Information LAN USB Interface 23151 Page 15 You may open up to two control panels simultaneously if no other LI USB application is running the USB server does not count Exit the programme via the menu File and End or by clicking the cross in the top right corner of the program window The program LI USB CV Editor This program enables you to program locomotive decoders on the programming track or in operational mode via your PC While programming on the programming track it is pos
2. LI_USB CV Edit Here you will also find the description files supplied with the product To picture the structure of a description file open an existing description and view its entries Lenz ELEKTRONIK GMBH Information LAN USB Interface 23151 Page 23 Structure of a description file Explanations in blue Lenz Gold Decoder This is the name of the decoder as shown in the heading of the editor Syntax 5 stars then an L for Lenz bit depiction or a blank for other bit depictions then the name 0 General CVs Address Below are the category names for the depiction of CVs in the program by category Syntax 5 then the category number 0 99 then the category name 2 Motor control 3 Speed parameter 4 Speed characteristic G This is the category of CVs that are used to depict the speed characteristic This is the only category with a G after the category name It may only be assigned to one category 7 Shunting mode 8 Function mapping 9 Function outputs 12 ABC functions 20 SUSI programming HHHH H1 1 127 0 0 3 Basic locomotive address This is the entry for a CV here CV1 its syntax is shown on the next page Lenz ELEKTRONIK GMBH Information LAN USB Interface 23151 Page 24 HHHHH Isolator The CV number here 1 The lower value threshold here 1 The upper value threshold here 127 The flag whether the bit depiction is activated for this CV O ac
3. not automatically mean that you may use them for operation even if you are dealing with devices for model railway control Do not expose the Interface 23151 to damp or direct sunlight Please contact us if you have any questions which this operating manual does not answer Postal Lenz Elektronik GmbH address H ttenbergstra e 29 D 35398 Gie en Phone 49 0 6403 900 133 The recorded message will inform you of times when we are available Fax 49 0 6403 900 155 E mail info digital plus de If you experience any problems with the Interface 23151 please contact us providing the following information e The devices you are using LZV100 LZ100 Compact etc e The version number of these devices and your Interface 23151 Lenz ELEKTRONIK GMBH Information LAN USB Interface 23151 Page 4 Control elements and displays Luminous diodes Three luminous diodes indicate the operational status of the Interface XpressNet red Initialisation complete device in operation XpressNet connected Data yellow Flashes during data transmission on the XpressNet to or from the Interface USB green USB connection established Reset button If this button is pressed and held before start up operating voltage fed to XpressNet connection all parameters of the device will be reset to factory settings e The factory firmware will be loaded and all updates deleted e The XpressNet address is set to 22 e The device is
4. of the browser Internet Explorer Firefox etc http xpressnet Tests with different routers have shown that calling up http xpressnet does not always work In this case enter the Interface s IP address in the address bar of the browser http 192 168 0 200 MacOS X Use Collections in Safari and click Bonjour The Interface will be displayed under Web pages Click Lenz XpressNet Interface Lenz ELEKTRONIK GMBH Information LAN USB Interface 23151 Page 8 Digital e gra lus als XpressNet Interface 23151 XpressNet Version 3 6 Softwareversion 1 0 Versionsdatum May 31 2011 23 40 45 XpressNet Adresse ndern WARNUNG Falsche Einstellungen k nnen zu verlust der Netzwerkverbindung f hren DHCP verwenden automatischer IP Konfiguration IP Adresse EA Subnetz Maske 255 255 2550 Gateway EA 0 lt s Ger tename XPRESSNET Speichern MAC Adresse 00 04 43 17 32 41 reer Copyright 2011 Lenz Elektronik GmbH Lenz ELEKTRONIK GMBH Information LAN USB Interface 23151 Page 9 Setting the XpressNet address The Interface has an XpressNet XBUS address just like any other Digital plus input device This address is used by the command station to call up the Interface The factory setting of the Interface s address is 22 lf you would like to change the Interface s address click the field that shows the current address You can change the value via the keybo
5. text contains information about the decoder features that can be changed with the selected CV When resetting a decoder by changing CV8 the manufacturer ID will be re read during the following read out Of course this does not correspond to the value which you have entered for the decoder set You will receive an error message which you can ignore Lenz ELEKTRONIK GMBH Information LAN USB Interface 23151 Page 20 At the bottom right of the tab All CVs you will find a maximum of five more buttons Read group Read all Default 3 wite group write all Read Write group Click this button to read write all CVs of the selected category Read Write all Click this button to read write all CVs defined in the decoder description Default value Click this button to enter the default value stored in the decoder description into the selected CV The tab General Settings C Edit Service track Standard Decoder loj x File Mode Display Speed curve _ Readvaues Addes A w Start voltage Rf Starting delay w Braking delay A w Write curve Read curve Standard Decoder Use these buttons to read out and change the decoder features used most often Lenz ELEKTRONIK GMBH Information LAN USB Interface 23151 Page 21 Programming the locomotive address is particularly easy here You do not have to choose between a 2 or a 4 digit address simply enter the address in
6. Digita jA lus by Lenz Information LAN USB Interface Art no 23151 1 edition 10 11 B 10 116 ELEKTRONIK GMBH Information LAN USB Interface 23151 Page 2 Contents Control elements and displays 2222a000000000nnnnnnnnnnnnnnnnnnn nun 4 mno I 2 gt SEEN EEE NEN enn een en ee eee ee nee ee 4 ROSSOI 21110 1 ee ee ELERSEERBEEEAEEAERENERNIEERENERER 4 XpressNet connection power SUPPIY uu uuu 2au2002a2000nan00nnanunnnnnenn 4 USB COHNECL ION ee einen 5 Information on installing and using the software can be found below from section Installing the supplied software u uuuuuunnnannnnnnnnnnnnnnnnnnnnnnnnn 5 Ethernet LAN connection 2 a22 222200 a0000aan0nnnnnunnnnnnnnannnnnnnunnnnnunnnn 5 Connection to a roOUter ueeeessannnnnnnnnneennnnnnnnnnnnnnennnnnnnnnnnnnnnnnnnnnnnnnnnnnennnnen 6 Direct CONNECTION to a PC unneeesseennenennnnnnnnnnnnnnnnnnnnennnnnnnnnnnnnnnnnnen san 6 UP A ND EE E EE A A E E 7 BEN WERTE eisen 7 a le 0 e E NE E E E E E OA 7 E Pe ee E A E EEE 7 Setting the XpressNet address 222222000000000200nnnnnnnnn nn nnnnnnnnnnnnne nennen 9 Installing the supplied software uuuunnanuennnannnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 10 The program LI USB Server 2 02220000000000nnnnnnnnnnnnnnnnnnnnnnnnnn 13 The program LI USB Throttle 0 2220000000002Bnnnnnnnnnonnnnnnnnnn nn 14 The program LI USB CV Ed
7. ard Please note that you may only enter values between 1 and 31 Moreover you may not use an address which is already being used by another XpressNet device When you have set the value click Save The new setting of the XpressNet address will be saved in the device The set XpressNet address will remain unchanged even after the device has been turned off However it can be changed again at any time Lenz ELEKTRONIK GMBH Information LAN USB Interface 23151 Page 10 Installing the supplied software Advice The software delivered with the product only functions with Windows XP and Windows 7 using the USB interface 1 Insert the supplied CD Information and software for USB interface into the CD ROM drive Click Start and then Execute Enter D Anwendungen LI USB msi and press Enter Replace D with the letter of your CD ROM drive as appropriate The program for the installation of the LI USB Server LI USB CV Editor and LI USB Fahrpult will be started Follow the instructions on the screen zox Welcome to the LI USB Anwendungen Lenz Setup Wizard ELEKTRONIK GMBH The installer will guide you through the steps required to install LI USB Anwendungen on your computer Click Next bo continue WARNING This computer program is protected by copyright law and intemahonal teabes Unauthorized duplication or distribution of this program or any portion of it may result in severe cv or c
8. damages resulting from the use or the inability to use the USB interface the supplied applications and documentation irrespective of any theoretical liability This is also true if Lenz Elektronik GmbH was informed about the possibility of such damages Reprint or duplication of any kind by permission of Lenz Elektronik GmbH only Windows Windows XP and Windows 7 are registered trademarks of Microsoft Corporation Acrobat Reader copyright Adobe Systems Incorporated All rights reserved Adobe and Acrobat are trademarks of Adobe Systems Incorporated and may be registered in certain jurisdictions 2011 Lenz Elektronik GmbH Lenz ELEKTRONIK GMBH H ttenbergstra e 29 D 35398 Gie en Tel 06403 900 133 Fax 06403 900 155 info digital plus de www digital plus de Lenz ELEKTRONIK GMBH
9. dernfalls an den Netzwerk administrator um die geeigneten IP Einstellungen zu beziehen IP Adresse automatisch beziehen Folgende IP Adresse verwenden IP Adresse 192 168 0 201 Subnetzmaske 25 255 255 0 Standardgateway 192 168 O 1 DNS Serveradresse automatisch beziehen Folgende DNS Serveradressen verwenden Bevorzugter DNS Server 192 168 O 1 Alternativer DNS Server f Erweitert Abbrechen Lenz ELEKTRONIK GMBH Information LAN USB Interface 23151 Page 7 IP addressing The factory setting of the Interface s IP address is 192 168 0 200 You may have to set your router to this address range in order to be able to access the Interface The Interface can be set to DHCP operation Information can be found in the Section Web Interface For practical use we recommend the use of a fixed IP address The subnet mask is 255 255 255 0 The TCP port is 5550 You can change the use of DHCP as well as the set IP as well as the subnet mask through the Web Interface Web Interface Since the Interface does not have a display a web server was integrated in the device The web server facilitates the displaying and changing of the IP configuration DHCP IP subnet mask and the XpressNet address The web server also facilitates the uploading of new firmware in the device The device can be found in the network as follows Windows Enter in the address bar
10. description file or create a new file with Notepad Aalen Assign a file name and add the file tm anse J e Al extension dec Make sure that Dateityp Files of type is set to Textdokumente Dateiname LENZ GOLD _DE dec Text documents when saving the oss frases th file f Advice Ordneroptionen x TE Allgemeine Informationen Ansicht Dateitypen To see the file extension the box et D atei n a m e n e rwe te ru n Q be Fe Sie k nnen das Erscheinungbild der Ordner vereinheitlichen bekannten Dateitypen ausblenden Ale Ordner zur cksetzen Hide extensions for known file types in the Folder Options of the Windows Explorer must be unchecked Erweiterte Einstellungen Dateien und Ordner I Ansichtoptionen f r jeden Ordner speichern Dateiattribute in der Detailansicht anzeigen Dateinamenerweiterung bei bekannten Dateitypen ausblenden Namen in Gro buchstaben erm glichen C Popup Informationen f r Objekte in Ordnem und auf dem Desktop a Schaltfl che f r Netzlaufwerkzuordnung in der Symbolleiste anzeige 5 Versteckte Dateien Alle Dateien anzeigen Versteckte Dateien ausblenden Versteckte und Systemdateien ausblenden ail Standard wiederherstellen OK Abbrechen bernehmen Description files MUST BE saved in the folder that contains the program file CVEdit exe After installation this is the folder Programme
11. e of the command Station if the option Programmiermodus automatisch beenden Exit programming mode automatically is deactivated The menu Display Show CV Values in categories You can view decoder CVs in the program window either by categories or by the order of the CVs The decoder description defines which CVs are displayed in which category Show bit values conforming to the Lenz standard This default option displays bits starting with 1 Untick this option to display bits starting with 0 The tab All CVs The left side of this tab shows a list of CVs defined in the respectively loaded decoder description During initial operation the description Standard decoder is loaded and displayed the CVs are shown by categories CVs are displayed and used as in the Windows Explorer Lenz ELEKTRONIK GMBH Information LAN USB Interface 23151 Page 18 Click to hide the list of CVs under E g Standard Decoder l 3 1 General Cv s the category and keep the overview A lab CVI Basic locomotive address r won ab CV Minimum starting voltage simple and clear vs CYS Starting delay pa lab C4 Braking delay Click a CV to see All CVs on the right hand side of the tab Read button Write button Value field Value range CV description General Settings Ne TEEN All CY s E E Standard Decoder wir General CV s Val 2 iia EIECYI Basic locomotive address re ab CY2 Minimum starting vo
12. ion to the XpressNet is correct and that the device functions properly Use the cable included in the package to connect the Interface to the USB interface U k Information on installing and using the software can be found below from section Installing the supplied software on Page 10 onwards Ethernet LAN connection The Interface is equipped with an Ethernet connection for use in a network This allows for up to eight simultaneous connections with other network devices Lenz ELEKTRONIK GMBH Information LAN USB Interface 23151 Page 6 You need a commercial Ethernet cable to use the LAN interface Which cable you use depends on whether ES s you want to connect the Interface directly toa PC or to a router Connection to a router The connection is usually made via a router If a WLAN router is used the Interface can be called via mobile WLAN devices You can use for example the software TouchCab http Awww touchcab com Connect the LAN interface of the Interface 23151 with a free LAN interface of the router Direct connection to a PC A direct connection to a PC is possible with a Xover LAN cable In this case the PC must be set to an IP address in the range of the Interface for example 192 168 0 201 Eigenschaften von Internet Protocol TCP IP 5 2x Allgemein IP Einstellungen k nnen automatisch zugewiesen werden wenn das Netzwerk diese Funktion unterst tzt Wenden Sie sich an
13. itor 02222020000000000BBnnnnnnnnnon nn nnnnnnn nn 15 TRE mMenu PIE ee ie ee 16 BS SS esse ee en ae sehe 17 The menu DISPlay cccccseeeceeseeeeeceeeeeceeeeeeeseeseeeseaeeesseeeessaneeeeneaes 17 The ab AlCVSs rnne een 17 The tab General Settings 224000000Rnnnnnnnnnnneennnnnnnnnnnnn nennen 20 Decoder CESCH OU ONS len ae 21 Creating decoder descriptions ss 222244000000Bnn0nnnnnnnneennnnnnnnnnnen nennen 21 Structure of a description file eee cece cecceeeeeeeeeeeeeeeaeeeeeeeeeeeseaeeees 23 Lenz ELEKTRONIK GMBH Information LAN USB Interface 23151 Page 3 Important advice please read first The Interface 23151 is a component of the Digital plus by Lenz system and was submitted to intensive testing before delivery Lenz Elektronik GmbH guarantees fault free operation if you follow the advice below The Interface 23151 may be used only with Digital plus by Lenz components Any use other than the one described in this operating manual is not permitted and all guarantees shall become null and void if the Interface 23151 is used inappropriately Connect your Interface 23151 only to devices which are designed for this purpose This operating manual will inform you which devices are suitable You must not operate the Interface 23151 with any other devices including those of other manufacturers even if they use the same connectors The fact that the connectors are similar does
14. ltage ab CV3 Starting delay ab C4 Braking delay ab CV5 Maximum speed When writing this CV CV19 multiple traction address is automal ab CV Version number decoder and Bit 6 is deleted in C 29 ab CVS Manufacturer s identification ab CV17 Extended locomotive address Basic locomotive address This is the number which is used to call up locomotives in the Din Read button Click L to read out the selected CV only possible if Programmieren auf dem Programmiergleis Programming on the programming track is selected in the menu Modus Mode The read out value will be displayed in the value field Write button Click S to enter the numerical value shown in the value field into the respective CV The program will automatically re read the value to ensure that it is correct if Programmieren auf dem Programmiergleis Programming on the programming track is Lenz ELEKTRONIK GMBH Information LAN USB Interface 23151 Page 19 selected The program detects and reports errors made when entering the value Value field The value field shows the read out value of a CV When loading a value file the value contained in the file for this CV will be displayed You can change the value by clicking the field and entering a different value via the keyboard Click the S button to enter the value in the CV Value range The value range permitted for the selected CV is shown here CV description This
15. ominal penalties ard vall be prosecuted to the masamum extent possible under the law Click Next Lenz ELEKTRONIK GMBH Information LAN USB Interface 23151 Page 11 i LI USB Anwendungen o xj Select Installation Folder Len Z ELEKTRONIK GMBH The installer will install LI USB Anwendungen in the following folder To install im this folder click Next To install to a different new or existing folder enter one below or click Browse Eolder E Programme IUS BY Browse You can install the software on the followang drives Diek Cost Cancel Previous Next The proposed installation folder is C Programme LI USB This can be changed as desired i LI USB Anwendungen pus Confirm Installation Len Z ELEKTRONIK GMBH The installer is ready to install LI USB Anwendungen on pow computer Click Next to start the installation Click Next Lenz ELEKTRONIK GMBH Information LAN USB Interface 23151 Page 12 ie LI USB Anwendungen m x Installing LI USB Anwendungen Lenz o ELEKTRONIK GMBH LI USB Anwendungen is being installed HUCOUUE UCU no The LI USB applications are now installed on your PC ie LI USE Anwendungen mi x installation Complete Lenz ELEKTRONIK GMBH LI USE Anwendungen has been sucessfully installed Click Close to exit Upon successful installation of the applications this windo
16. set to the fixed IP address 192 168 0 200 Pressing the button during operation has no effect XpressNet connection power supply The Interface is supplied via the XpressNet connection To make the connection connect the XpressNet socket to the command station LZ100 LZV100 Use cable 1 included in the package to connect the XpressNet nn Plug one end into the XpressNet socket of the Interface 23151 and connect the other end to an adapter LA152 Lenz ELEKTRONIK GMBH Information LAN USB Interface 23151 Page 5 If you want to connect the Interface 23151 to AL the terminal screws LMAB of a LZ100 LZV100 command station simply cut the cable in the middle and connect the cable wires to the corresponding terminal screws The pin assignment is shown in the B illustration on the right do not use M do not use The factory setting of the Interface s XpressNet address is 22 This setting can be changed through the Web Interface see Section Web Interface in the framework of the XpressNet specification USB connection The USB connection can be used in parallel to the LAN connection The driver can be found in the directory USB Driver When connecting the Interface to the USB port of the PC Windows will ask for the location of the driver Indicate the directory We recommend that you use the applications delivered with the Interface for the initial operation since this allows you to verify that the connect
17. sible to read out CV values Decoder descriptions ensure that you do not have to remember which CV is responsible for which feature These descriptions can be loaded into the CV editor in which case the CVs and their respective features will be displayed You can also save decoder values In combination with the decoder descriptions you can save the CV settings for each decoder used on your PC and reload them into the decoder if required Start the program by double clicking the icon LI USB CV Editor on your desktop El LI USB C Editor Once the program has been started the program LI USB Server is started automatically at the same time the decoder description Standard decoder is loaded Lenz ELEKTRONIK GMBH Information LAN USB Interface 23151 CY Edit Service track Standard Decoder fe x Fie Mode Display General Settings E E Standard Decoder 0 General CVs lab CV1 Basic locomotive address ab CV2 Minimum starting voltage ab CY3 Starting delay lab CV4 Braking delay ap CV5 Maximum speed ab CV Version number ab CVS Manufacturer s identification lab CV17 Extended locomotive address ab CV18 Extended locomotive address lab CV19 Multiple traction address ap CV29 Settings 1 ab CV50 Settings 2 0 Motorcontrol 0 Characteristic speed line Read group Read all Write group Write all Standard Decoder This
18. the address field The settings of CV1 CV17 CV18 and CV29 are automatically taken over by the program Read Write curve Use these buttons to adjust the characteristic speed line Click Read curve to read out the appropriate values and to display the resulting speed line graphically Use the mouse to edit the speed line click and draw The program automatically calculates the related values Click Write curve to enter the values in the locomotive decoder Decoder descriptions These decoder descriptions are supplied with the CV editor LENZ Gold Decoder_DE decoder description for the GOLD series decoders e LENZ SILVER_DE dec decoder description for the SILVER series decoders e Standard _DE dec decoder description for the STANDARD decoder Standard _EN dec and LENZ GOLD_EN The description Standard contains all CVs defined by the NMRA The description Gold decoder contains all CVs used in these decoders Creating decoder descriptions A decoder description file is a text file that can be edited with any simple editor If you want to create your own or edit existing description files make sure that the file extension remains dec when saving It is easiest to use the Windows program Notepad to create or edit description files Lenz ELEKTRONIK GMBH Information LAN USB Interface 23151 Page 22 Please do not forget to back up the descriptions supplied with the product Open an existing
19. tive 1 inactive The number of the category to which the CV belongs here 0 Attention If the category itself see above is not defined this CV will not be displayed by category Default value ofthe CV Description Additional lines with explanatory texts may follow H HHHH 1 1 127 0 0 3 Basic locomotive address Important Do not forget the commas between the values Lenz ELEKTRONIK GMBH Information LAN USB Interface 23151 Page 25 All rights reserved Error and changes due to technical progress product maintenance or changes in production methods excepted We accept no responsibility for direct or indirect damage resulting from improper use non observance of instructions use of transformers or other electrical equipment which is not authorised for use with model railways or which has been altered or adapted or which is faulty Furthermore we accept no responsibility for damage resulting from unauthorised modifications to equipment or acts of violence or overheating or effects of moisture etc In all such cases guarantees shall become null and void The customer uses the USB interface the supplied applications and documentation at his or her own risk Lenz Elektronik GmbH is not liable for damage caused or incurred by the user or third parties as a result of such use In no event shall Lenz Elektronik GmbH be liable for lost sales or profits or the loss of data or direct indirect special logical accidental or punitive
20. w will pop up Click Close to exit the installation Lenz ELEKTRONIK GMBH Information LAN USB Interface 23151 Page 13 Upon successful installation three new icons will be displayed on your desktop LI USB Server LI USB CY Editor LI USB Fahrpult The program LI USB Server The program LI USB Server provides a TCP IP server for the other applications It ensures secure communication between these applications and the USB interface It is automatically started together with any of the three applications If the Interface is correctly connected to zioz the USB port of your PC and the File Server Language Broadcast ports in use Digital plus by Lenz system is active a communication between the Interface and the PC is automatically established Start server If the Interface is not connected or the Li Server aj USB driver is not installed you will EN receive an error message In this case check all connections between the PC and the Interface The USB server allows two applications to simultaneously access the Interface and therefore the Digital plus by Lenz system This feature is particularly useful if you want to use the control panel to test decoder settings that you have changed with the CV editor Lenz ELEKTRONIK GMBH Information LAN USB Interface 23151 Page 14 The program LI USB Throttle This program enables you to control locomotives on the Digital plus by Lenz
21. window is displayed once the program has been started The menu File Open decoder description file Here you can select and open a decoder description file By default decoder description files are stored in the folder where the program files are installed Unless you have chosen a different folder during installation this is C Programme LI USB but you may also choose any other folder Load decoder values This command enables you to load a value file for a decoder This file contains the CV values Load the appropriate decoder description first Save decoder values This command enables you to save the values which have been read out of the decoder or entered into the CVs of the decoder in a file Lenz ELEKTRONIK GMBH Information LAN USB Interface 23151 Page 17 End Strg Q This command terminates the program Alternatively you can use the key combination Ctrl Q or click the cross in the top right corner of the program window The menu Mode Programming on the service track Programming on the Main Use these two commands to select the programming mode It is impossible to read out CV values when programming in operational mode Finish programming mode automatically When programming on the programming track choose this option to exit the programming mode of the command station after each read out or programming procedure End programming mode now Use this command to exit the programming mod

Download Pdf Manuals

image

Related Search

Related Contents

0120-781-603 - 自転車  BUM AND THIGH TONER™  N o tice d `e m p lo i TiM H 2 0 0  

Copyright © All rights reserved.
Failed to retrieve file