Home
User`s Manual for ZKMD3 Series IR Vandal-proof Dome
Contents
1. Overview 1 4 Product Appearance e Diagram of ceiling mounted mode fixing base camera transparent cover e Diagram of wall mounted mode wall mounted bracket fixing base e Dimensional drawing of ceiling mounted mode in mm Right View e Dimensional drawing of wall mounted mode in mm User s Manual for ZKMD3 Series IR Vandal proof Dome IP Camera V1 7 Front view Overview 1 5 Connecting Terminals 1 1 Power Interface Connect to the adapter This IPC employs the power supply of DC 12V and no lower than 1 5A Do not use any different power supply as it may damage the camera 2 Network Interface 10 100M self adapting Ethernet interface is used to connect the camera with various network equipments such as switch router and hub When it is connected to 10M network the orange lamp is also on When it is connected to 100M network the green lamp is always on This interface can also employ Ethernet power supply POE optional and allow the transmission of power and data through Ethernet cable PoE Swicth EPIA A ue E y D 3 Reset Button When the camera fails to function during incorrect operation or accidental failure e g forget IP address or password or it is used in different scenes press down the button for above 5s after a delay of 30s from powering on to restore the camera to its factory defau
2. e g http 192 168 80 123 press Enter to open the following login interface Canet fled server Mirmo Intervet Expira http 192 168 30 123 2 Type in user s name and password and click OK and the guide page will show as below initial use 3 Click Watch the video to enter Preview interface 19 User s Manual for ZKMD3 Series IR Vandal proof Dome IP Camera V1 7 612 07 ZS5 10 23 45 OR When accessing the device via browser for the first time it is necessary to download the control More details about how to use browser for video surveillance please refer to User Manual Using Browser for Video Surveillance in the supplied CD 3 2 Using RTSP Media Player 1 Download and install a media player supporting RTSP protocol e g VLC media player 2 Open the media player select the menu Media Open Network Stream pop up the input interface of URL 20 Accessing device gt FLC media player ECHES Playback Audio Video Tools P Open File Ctr1 0 Advanced Open File Ctr1 Shi t 0 CJ Open Folder Ctrl F 5 Open Disc Ctrl D E Ctrl H Ctrl C View Help Y a Open Ne EX Open Capture Device Ctrl1 V Open Location from clipboard Recent Media Save Playlist to File Ctrl Y Convert Save Ctrl R te Streaming Ctrlt s XK Quit Ct
3. 85 bus must be connected to a 1202 terminal resistance in parallel Pay attention to provide lightning protection if the camera is mounted outdoor Do not touch the camera during lightning User s Manual for ZKMD3 Series IR Vandal proof Dome IP Camera V1 7 11 Use the camera in the working conditions Ambient temperature 20 C 55 C ambient relative humidity 10 95 RH ola es INS I 12 Please keep the lens and transparent cover clean If the transparent cover is dirty please wipe it with clean soft cloth 14 Installation and Network Configuration e Ceiling mount installation method wiring hole e N ee am ss A PJ x positioning 14_ p AS a Installation template for ceiling mounted mode unit mm aAffix the paper template to the ceiling and drill holes according to the marked circles in the paper template Affix the camera and pedestal to the ceiling by 4 screws Adjust the lens angle to appropriate surveillance area Tighten the screws to fix the transparent cover User s Manual for ZKMD3 Series IR Vandal proof Dome IP Camera V1 7 o Wall mount installation method 4 8 50 0 4 A amp 304 5 5 N o 4 j o i wiring hole Bs positioning hole Installation template for wall mount method unit mm aAffix the paper template to the wall and drill holes acco
4. HIPlayer to enter the media player Neg 14 07 a gt QS ga 23 User s Manual for ZKMD3 Series IR Vandal proof Dome IP Camera V1 7 3 Click the button E at the lower right corner to the setting interface type in the user name password domain name and port of the device or select a set device from the favorite egos AMES v3 AA HIPlayer At 11zkipcam zkivision cc 4 Click Play and the medial player will play the real time video of the device Note 1 The operating system of mobile device must be Android BlackBerry or iOS 2 As the internet service is required for watching video please consult with your internet service provider for specific charges 24 Accessing device 3 4 Using Video Surveillance Software ZKiVision Client Software is our company s free video surveillance software which can help manage and monitor multiple devices in a real time manner Install the software in the supplied CD and add devices to the software Then the real time monitoring can be started If needed to learn about how to use the video surveillance software refer to ZKiVision Client Software User Manual in the CD 25
5. Stream 1280x720 Secondary Code Stream 320x240 Video Frame Rate 1 25 frames optional Video WDR HD Parameters Brightness Saturation Contrast Illumination Sensitivity Shutter Image Up Down Image Left Right Night Vision Mode Wide Dynamic Mode adjustable HD Brightness Saturation Contrast Image Up Down Image Left Right User s Manual for ZKMD3 Series IR Vandal proof Dome IP Camera V1 7 adjustable Functional Interfaces Audio Interface 1 Mic input and 1 linear output optional Alarm Input 1 alarm input normally opened or normally closed optional Alarm Output Motion Detection 1 switch output maximum working voltage AC 120V 1A DC 24V 1A Allow 4 independent detection areas Control Interface 1 RS485 Memory Support TF card for video storage and image capture 32G maximum optimal Network Interface 10Base T 100Base TX Ethernet interface WiFi 802 11b g wireless optional Supported Network TCP IP HTTP TCP ICMP UDP ARP IGMP SMTP FTP DHCP Protocols DNS DDNS NTP UPNP and RTSP etc Working Environment Input Power DC 12V 1 5A POE Ethernet power supply comply with 802 3af regulation optional Maximum Power Consumption 8W Working Temperature 20 55 C Working Humidity 10 95 RH Level of Protection IP66 Installation Mode Wall mounted
6. User s Manual for ZKMD3 Series IR Vandal proof Dome IP Camera Document Version 1 7 Date 2012 10 Introduction This document mainly introduces the functional features installation process and access methods of ZKMD3 series IPC Important Notices Thanks for selecting our company s IPC Before use please read through the user s guide to avoid any unnecessary damage All functions depend on the actual product Since the product is subject to updating our company is not responsible for any difference from this guide and not liable for any dispute over different technical parameters from this guide The project is subject to any change without notice To learn more please visit our company s website www zkivision com or local office Table of Contents Table of Contents 1 OvervieW E E EE E E E S 1 1 1 Product Descrip iia e E E a 1 12 Product Pee S titi r a a ee a e e a e a ae a 1 1 3 Technical Parametros 3 VA Product A PPM ia 5 1 5 Connecting TM is 7 1 6 Basic Procedures isc 11 2 Installation and Network Configuration o mmommommsmmsmssmss 12 2 1 Hardware Installation eeina e iatea nnee aan AASR Ena E 12 2 2 Operating ENVirONIMENt oooccnccccncnnnononcnnnonononnnononncnnonnono aia iia 17 2 3 NetWork Connection sc sccacccececceseseacssssencecsenncencuroncsnvecdeassancenedesencausnsencuntened 17 3 ACCESSING device seseseoseseesososeseseseseosososcocososcocoroseseseseseosososoeeoresesesesesse
7. Video Surveillance 2 The schematic diagram of alarm output default connection is as follows Alarm Output Terminals Alarm COM NO switch Output Device Power Supply of Alarm Output Device Schematic Diagram of Alarm Output Normally Opened Connection Dm The connection with normally opened alarm output e g normally opened lock is performed as shown in the following schematic diagram Alarm Output Terminals s Alarm COM NO switch Output Device Power Supply of Alarm Output Device Schematic Diagram of Alarm Output Normally Closed Connection 5 R5S485 Interface Supports standard 485 PTZ protocols for remote device control The camera can be turned remotely and monitored in all directions User s Manual for ZKMD3 Series IR Vandal proof Dome IP Camera V1 7 The relevant parameters are set as detailed in User Manual Using Browser for Video Surveillance The specific interface is shown in following figure 485 g 485 E GND o EZI Audio Input Interface Connect to external audio acquisition e g MIC for sound acquisition as detailed in User Manual Using Browser for Video Surveillance Audio Output Interface Connect to audio player e g active speaker for sound broadcasting Analog Video Output Interface Specia
8. ally during operation please cut off the power before check Do not connect cables when power is on Orr The wiring during power on may seriously damage the camera which will be disqualified from the guarantee DC12V 1 5A 4 Use the power supply of DC12V and no lower than 1 5A for the camera or PoE power supply optional Too high or low voltage or AC power supply may cause the abnormal operation of the camera 12 Installation and Network Configuration 8 10 Use the standard power cord when the power supply is too far away from the camera and consider the voltage drop caused by long distance Read through the instructions for connecting terminal and wire strictly according to interfaces Any damage to the camera due to improper operation will be disqualified from the guarantee All the exposed parts of connecting terminal should not exceed 5mm in order to prevent any accidental contact from damaging the camera Uncovered cable should be less than 5mm Mount the relay equipment in the middle to avoid signal attenuation when the straight communication distance from the camera to the incoming equipment exceeds 80m Fa Please use repeater when exceeding 80m When RS485 is employed if the communication distance exceeds 100m the final equipment on the 4
9. amp shining 2966 4 In the Start menu select Programs Accessories Command Prompt and input the ping command to the device address e g type in ping 192 168 1 88 If Request timed out does not pop up the device is successfully connected to network 17 User s Manual for ZKMD3 Series IR Vandal proof Dome IP Camera V1 7 a 1 The default IP address is 192 168 1 88 and the default HTTP port is 80 If needed to change IP address or port refer to Network Setting in User Manual Using Browser for Video Surveillance 2 If the device is in a network section different from computer refer to How to Visit IPC on Internet in User Manual Using Browser for Video Surveillance for the connection during different network sections iii Comnect to Wireless Network Before starting the wireless network connect the IPC to network by Ethernet cable visit the device through browser enter Network Setting interface and set the wireless network connection following the operating procedure as detailed in Network Setting in User Manual Using Browser for Video Surveillance 18 Accessing device 3 Accessing device There are 4 methods can be used to access the device Browser RTSP Media Player Mobile Device and Video Surveillance Software ZKiVision client software 3 1 Using Browser 1 Open a browser type in the dynamic domain name or IP address of the device
10. l for SD camera and engineering commissioning After being installed and connected this interface can be used locally to connect with the image display device and adjust the camera angle to the appropriate monitoring area according to the scene in the video 10 Overview 1 6 Basic Procedure 10 Unpack and check whether any component is missing Connect the camera to computer by means of patch cable If your computer IP is in a network section different from camera IP please set it to the same network section as camera IP such as 192 168 1 87 Log in the camera through client software or browser to check whether the video functions normally Adjust the code stream and other video parameters Modify the network parameters of camera and reboot the device Repeat Step 3 Revisit the camera through client software or browser to check till the video functions normally Install the camera and adjust the camera angle to the appropriate area Visit the camera through client software or browse for video monitoring 11 User s Manual for ZKMD3 Series IR Vandal proof Dome IP Camera V1 7 2 Installation and Network Configuration 2 1 Hardware Installation e Installation Notices 1 Read through the guide for installation prior to installation 2 Check whether any component is missing against the packing list if yes please contact your supplier 3 Wire during power off If the camera does not function norm
11. lt The default user s name is admin the default password is admin and the default IP address is 192 168 1 88 User s Manual for ZKMD3 Series IR Vandal proof Dome IP Camera V1 7 1 Alarm Interface Connect to alarm input and alarm output When the camera receives an alarm from alarm output or Web motion detection this interface can send a signal to alarm output to realize real time monitoring and overall protection while triggering a remote alarm The specific interfaces are presented in the following figure NC D COM o Atarm output m w NO o GND 2 i SIN Alarm input The schematic diagram of alarm input connection is as follows Alarm Input A Terminals Y Alarm IN GND switch Input Device Power Supply of Alarm Input Device Schematic Diagram of Alarm Input Normally Opened Connection Alarm Input A Terminals 4 Alarm IN GND Switch Input Device Power Supply of Alarm Input Device Schematic Diagram of Alarm Input Normally Closed Connection Overview Os When external alarm input is started different alarm inputs have different software settings Please select Normally Opened or Normally Closed on the Web page according to the type of alarm input as detailed in User Manual Using Browser for
12. occasions requiring remote network video 1 2 Product Features eo Hi3512 high performance multimedia processor supporting H 264 Main Profile video coding e Dual code stream suitable for various networks o Support all kinds of protocols such as TCP IP HTTP TCP UDP ARP SMTP FTP DHCP DNS DDNS NTP and UPNP etc e Aluminum alloy die casting design IP66 protection grade and best dustproof waterproof anti corrosion and anti riot effect Either wall mounted or ceiling mounted and wide scope of uses Snap on base to simplify the installation User s Manual for ZKMD3 Series IR Vandal proof Dome IP Camera V1 7 Safe and reliable socket head lock screws Double glass front cover for better optical isolation and mist prevention surface for better night viewing Three layer shield magnetic ring design to eliminate signal interference Numerous additional functions e g alarm audio talkback 485 control TF card and reset etc Support Ethernet power supply PoE 802 3af regulation optional Support WIFI 802 11b g n standard wireless network module optional IR Cut filters to automatically switch between day and night for optimal monitoring Double web indicator lamps for easy judgment of web status 4 9mm focus adjustable lens adjusted according to different environment Analog video output interface for HD to facilitate site commissioning Self recovery from abnormality and auto reconnection after net
13. rding to the marked circles in the paper template Affix the pedestal to the wall by 4 screws Hang the camera in the pedestal and tighten the 4 screws to fix the camera in related pedestal Take off the transparent cover from camera by screwdriver and adjust the lens angle to appropriate surveillance area Tighten the screws to fix the transparent cover 16 Installation and Network Configuration 2 2 Operating Environment Operating System Windows 98 Windows2000 2003 XP Vista Windows 7 CPU Pentium III 1GHZ or higher Memory 256MB or higher at least 128MB possibly affect performance and some functions HDD 1 5GB available Screen Resolution 800x600 or higher Browser IE6 0 or latest version A better computer can considerably improve the effect of monitoring so it is recommended to use a better computer for monitoring 2 3 Network Connection The device can be connected to network in two ways The first way is to connect to the network by means of Ethernet cable and the second way is to connect to wireless network optional sites aha ee Connect by Ethernet Cable 1 Use Ethernet cables to connect the device to network or directly to computer 2 Connect the power supply of the device 3 During normal connection if it is a 10M network the orange lamp is always on if it is a 100M network the green lamp is also on The physical connection with network is completed after the l
14. rl q 3 Type in the network URL in the form of rtsp lt IP address gt lt RTSP port gt lt stream code gt Open Hedia File a Disc Network Ef Capture Device Network Protocol Please enter a network URL rtsp 192 168 80 187 11 http wow example com stream avi rtp 1234 mms mms examples com stream asz rtsp server example org 080 test sdp http w rourtube com watch v 2264x C Show more options 21 User s Manual for ZKMD3 Series IR Vandal proof Dome IP Camera V1 7 4 Click Play and the media player will play the real time video of the device J 1 a aa eee wasp 182 188 60 508 11 O Note 1 The default RTSP port of device is 554 If it must be modified please refer to User Manual Using Browser for Video Surveillance in the supplied CD 2 If it is necessary to learn about how to use RTSP media player for video surveillance please refer to User Manual Using Browser for Video Surveillance in the supplied CD 3 3 Using Mobile Devices Tf it is necessary to use mobile devices for video surveillance please firstly ensure the device can be accessed on Internet Please refer to User Manual Using Browser for Video Surveillance in the supplied CD for more details about how to visit device on Internet 22 Accessing device 1 Install the media player in the supplied CD into the mobile device 2 Click the icon
15. sesesessosesesee 19 3 7 Using BO WS Eee ea aaa NEE CAE eE EEEE S 19 3 2 Using RTSP Media Player ooococonocinocoonoononononnonnnonncononononononnconorononconanonncnnos 20 3 3 Using Mobile Devices oooonconconicoccoconnnanonnnncnnconcnn cnn rn nononn canon cn nonn na nananncncnnns 22 3 4 Using Video Surveillance Software ooononionococnnononcnnnanononanonono canon nono rncnncnnnno 25 Overview 1 Overview 1 1 Product Description The ZKMD3 series products are day night vandal proof color IP cameras which feature the aluminum alloy die casting design and IP66 protection grade The series products are equipped with 2 megapixel CMOS sensors or high quality CCD sensors made by Sony which feature the long distance infrared lamp projection wide projection angle and night vision capability The optimized H 264 coding algorithm guarantees the transmission of sharp and smooth video effect The embedded Web Server enables users to conveniently implement real time surveillance and remote control for front end cameras via browser The series products are either megapixel high definition or common pixel standard definition cameras which can be wall mounted or ceiling mounted easily installed and operated and used in indoor or outdoor places The products are applicable for the places requiring short distance and wide angle tight security and all weather surveillance such as residence communities factories and banks as well as the
16. work interruption Automatically capture images during an alarm and send them to the designated email Support motion detection and external detector alarm Allow setting several alarm times and support the remote alarm linkage Support dynamic IP DHCP and dynamic domain name system DDNS Network time synchronization NTP HD cam to support the browsing by 14 users simultaneously 4 in primary code stream and 10 in secondary code stream SD cam to support the browsing by 20 users simultaneously 10 in primary code stream and 10 in secondary code stream Overview 1 3 Technical Parameters Product Name Anti Riot Infrared Semi Spherical IP Camera Product Model ZKMD372 ZKMD352 Cam Properties Image Sensor 1 3 megapixel progressive 1 3 2 two megapixel CMOS sensor progressive CMOS sensor WDR HD HD Image Resolution 1280x720 Day Night Switch IR Cut filter switch Type of Lens 4 9mm manual aperture lens Minimum Brightness 1 Lux IR lamp off 0 Lux IR lamp on IR Lamp 25 built in 5 infrared lamps 10 15m effective projection distance 60 degrees projection angle Primary Processor Video Coding Hi3512 Operating System Embedded Linux Video Compression Algorithm H 264 main profile level 3 Audio Compression Algorithm G 726 G 711 Video Compression Code Rate 32 6114 Kbits s adjustable Video Resolution Primary Code
Download Pdf Manuals
Related Search
Related Contents
HUMAN ADULT STEM CELLS - Zen カタログpdf Philips 191E1SB 2015 Action Guide for Watershed Assessment and Restoration H2SMART Studio SOFTWARE USER MANUAL ダウンロード - Vector Mode d`emploi simplifié de ®REGRESSI Utilisation pour le Bedienungsanleitung FW 100 Regler [ pdf / 3 MB ] Monte Carlo Fan Company 5ROR User's Manual Accu-Chek Aviva US Multiclix Manual Copyright © All rights reserved.