1. FIREFIGHTING EQUIPMENT MERCATOR Monitor DNS0 3000 l min POK SAS ZI Les Guignons 10400 Nogent sur Seine FRANCE Tel 03 25 39 84 78 Fax 03 25 39 84 90 Email france pok fr Web www pok fr 0 J C il 2 i J Coryright POK SAS DOC 1963 EN Rev A 28 08 2013 IdDentificotion e MERCATOR 3000 DN100 3000 l min Ref 03487 07770 Product Reference concerned by the manual References 03487 07770 15862 used for all visuals 1963 Modification Date SSS O Review follow up ish ala POK SAS ZI Les Guignons 10400 Nogent sur Seine FRANCE Tel 03 25 39 84 78 Fax 03 25 39 84 90 Email france pok fr Web www pok fr Toble of Contents IDENTIFICATION aa aan a ea ana nantes aa ae ERAR A n ant Da mEneen 2 TABLE OF CONTENTS a a ee 0 ten 3 INSTRUCTIONS ame anse en sems ea dan anne rasta ba ATER EAEE 4 IN OC ee E A EAA E N EAE A E A A 4 DisManting and WATER ete des E R AEA a 4 w UEI OT e E E E A A E E E AAG EEE 5 LACS OS a a A ein nt 5 PRESENTATION aa DAER A cen OAA ENEA AA EAN 6 VERV TE W rr canteen ate acess N E EE E E A A E vanes ANE a oo 6 DETAILS na en a EEEE A EEEE EENE E ESE AA 7 CONSO D E E E E A EA 7 sara Babe PP AAT AN 7 LAV OD sees I E E E A A A A A O 8 USAGE INSTRUCTIONS ns nsscsnrsessaua manne anseers eee aasuenas ea aum een ntauin ent 9 INSEALA RO N a a ae non 9 PROD Rd eat en 9 CONDO ON Sec de ee ee ee saean 9 MOUNDO ee oe ee
2. e Preamble Please read the manual before placing the equipment in service Not respecting the advice in this manual could render the product dangerous The diffuser is built to function to a maximum of 3000 litres a minute at 7 BAR pressure e Connection The connection of the monitor on its support must be performed according to applicable safety rules and by personnel trained in its use Le branchement de la lance sur son support doit tre effectu dans les r gles de l art par du personnel form la mise en service de ce type de mat riel Use the screws washers bolts and gaskets not supplied Suitable for the monitor Bride DN 80 Bride DN 100 190 5 mm 72mm 19 mm 152 4 mm 160 mm e Mounting Connect the diffuser or branchpipe not supplied to the outlet connection of the monitor Make sure that the seal is clean and tight POK SAS ZI Les Guignons 10400 Nogent sur Seine FRANCE Tel 03 25 39 84 78 Fax 03 25 39 84 90 Email france pok fr Web www pok fr DOC 1963 EN Rev A 28 08 2013 Coryright POK SAS Coryright POK SAS DOC 1963 EN Rev A 28 08 2013 Usage Manve l Use Before placing under pressure 1 Check that no parts are damaged or missing 2 Check that the branchpipe is correctly connected to a water supply Please make sure you have at least 5 meters of straight hoses after the monitor s inlet mark
3. 1 Check that no pieces are missing or damaged 2 Connect the equipment to a water supply 3 Put a stopper with an air vent on the monitor outlet 4 Test the monitor by progressively increasing the pressure until you reach 16 bar Check for any leaks 5 Place a diffuser or branchpipe on the monitor 6 Tester ensuite la lance en condition d utilisation normale avec une pression de 7 bar S assurer que les parties mobiles bougent sans aucun point dur ou blocage L op ration doit durer environ 10 min If no fault is found the monitor can be placed back in service If you conduct your own maintenance it is possible that the hydraulic values of the material may not be listed to the same level as the original product Only maintenance conducted at the POK factory can guarantee a precise calibration of the equipment WARNING During the test procedure it is necessary to take special precautions Only personnel directly involved in the return of service testing of the product should be near the product If the parts are not connected securely they may eject and cause serious damage e Spare Parts Some parts such as gaskets are likely to be changed more or less often depending on the frequency of use conditions of use or storage Please contact our sales department for the prices and after sales conditions Refer to the bill of materials in this document to identify the replacement parts Note The serial number of th
4. Seine FRANCE 4 Tel 03 25 39 84 78 Fax 03 25 39 84 90 Email france pok fr Web www pok fr Instructions e Utilisation Veuillez respecter les limites techniques du mat riel e Use Please respect the technical limits of the equipment The recommended work pressure is 7 bar 100 PSI The efficiency over this pressure is not guaranteed Do not use the monitor over 16 bar 230 PSI The equipment can be damaged over the recommended pressure The apparatus can not be used if any part is missing or damaged Never stand in front of the monitor or point the monitor at somebody It can cause death Please note that use of the monitor may cause damage in the area of the horizontal range Ensure that the area is safe and clear before the use Disrespect of safety instructions and use of the monitor over the recommended pressure can be dangerous and even cause death It is important to Know and respect the safety rules regarding your operating environment POK SAS is not responsible of any accident that may occur during operation caused by improper use or non compliance with safety requirements e Limits of use POK guarantees the function of the equipment up to a maximum operating pressure of 16 BAR 230 PSI POK SAS guarantees the function of this equipment up to a maximum test pressure of 25 5 bar 370 PSI in closed position Without explicit written authorization from POK the warranty will be void if the pressur
5. B 3 Check that the rest of the equipment is correctly connected 4 In case it is used on a mobile base make Sure that the stabilizing legs are in place and secured 5 Check that the supports it sufficiently strong enough to resist the reaction force and that the monitor is securely anchored using the attached strap 6 Ensure that all safety pins are in place Note To obtain optimal performance respect the following limits Maximum Flow rate 3000 I Min or 790 GPM Usage Pressure 7 bar or 100 PSI Never point the stream at another person Never use the monitor at a horizontal angle of less than 90 If your monitor is equipped with a spray jet option make sure that there the area around the monitor is clear and safe before using the spray option POK SAS ZI Les Guignons 10400 Nogent sur Seine FRANCE Tel 03 25 39 84 78 Fax 03 25 39 84 90 Email france pok fr Web www pok fr Usage Manvue l Settings e Setting the elevation range The monitor is adjustable in vertical range o vertical axis of x 90 from 90 to 902 1 Pull the vertical range safety locking pin ark 2 Adjust the elevation hight using the handle Mark B 3 Place the safety locking pin back in place Mark C Mark A Mark B Mark C e Horizontal range adjustment The monitor is adjustable in horizontal range Horizontal adjustment axis of 360 1 Loosen t
6. e branchpipe may be requested to verify the validity of the warranty POK SAS ZI Les Guignons 10400 Nogent sur Seine FRANCE Tel 03 25 39 84 78 Fax 03 25 39 84 90 Email france pok fr Web www pok fr DOC 1963 EN Rev A 28 08 2013 Coryright POK SAS DOC 1963 EN Rev A 28 08 2013 Coryright POK SAS Exploded view POK SAS ZI Les Guignons 10400 Nogent sur Seine FRANCE Tel 03 25 39 84 78 Fax 03 25 39 84 90 Email france pok fr Web www pok fr Bill of Masferislis ary POK SAS ZI Les Guignons 10400 Nogent sur Seine FRANCE Tel 03 25 39 84 78 Fax 03 25 39 84 90 Email france pok fr Web www pok fr DOC 1963 EN Rev A 28 08 2013 Coryright POK SAS Coryright POK SAS DOC 1963 EN Rev A 28 08 2013 NOTES POK SAS ZI Les Guignons 10400 Nogent sur Seine FRANCE Tel 03 25 39 84 78 Fax 03 25 39 84 90 Email france pok fr Web www pok fr DOC 1954 FR Rev A 05 08 2013 Coryright POK SAS
7. e covered by special written agreement The exploded view and bill of materials are not a dismantling manual Any dismantling or maintenance operation of the device must be done with water supply turned off Dismantling and or modification of the equipment outside POK SAS factory is allowed only in compliance with procedures described in this manual and therefore does not affect the warranty If the equipment is repaired the spare parts must be supplied by POK SAS If not technical characteristics listed in this document won t be valid the warranty will void and POK SAS responsibility will not apply If maintenance operation damage parts the warranty may not apply if the procedure has not been carried out properly in accordance with this manual Although this is not explicitly stated in instructions use and wear of protective equipment are obligatory during maintenance operation POK SAS cannot be responsible of any damage or accident which may occur during the dismantling If this obligation is not met please refer to the tools instructions guides for more details Only POK SAS can ensure proper and safe functioning of the equipment Therefore POK SAS will not be liable for any damage or accident caused by dismantling of the equipment outside its workshop Do not modify the equipment it may not be working or be dangerous for use Any modification not approved by POK will void the warranty POK SAS ZI Les Guignons 10400 Nogent sur
8. ee ee ee er ee ere 9 Mo De a pen ee a 10 Before placing under pressure ssssssesssssnssrsrrnnnnrnnrnrnnsnnnnrnrrnrsrenesnrnrunrnernrnrrnne 10 EN a a E A E A 11 e Setting the elevation range sssssssssssssnsnsnnasornnnnsesensnsnenennennnsnennanorennnenensenns 11 Horizontal range ACTUS AMENER a te a 11 MAINTENANCE a AE EAA a EE AEEA es 12 e Monitor maintenance proceduresS nana made nana one crains 12 Gr asing the MOMIE rise asansdens ANTEE ERR an ardent en in 12 e Returning to service procedure s sssssssasssssasorsnonenssnsnsnennaronnnensnruronnneneasennnss 13 EXPLODED VIEW a ne er ee er rere rrr 14 BILE OF MATERISLS one aa nak ee yeaa ume en aie 15 NOTES a ee EE A EA E E E er ee ren rT ee 16 POK SAS ZI Les Guignons 10400 Nogent sur Seine FRANCE Tel 03 25 39 84 78 Fax 03 25 39 84 90 Email france pok fr Web www pok fr DOC 1963 EN Rev A 28 08 2013 Coryright POK SAS Coryright POK SAS DOC 1963 EN Rev A 28 08 2013 Instructions e Introduction Please read this manual before using the equipment Use maintenance or any other operation of the equipment must be done by staff trained for the use of this equipment and aware of any safety rules While using the monitor use maintenance installation it is important to wear personal protective equipment e Dismantling and warranty This equipment has a warranty of 1 year for any fabrication default except wher
9. es listed above are exceeded POK SAS ZI Les Guignons 10400 Nogent sur Seine FRANCE Tel 03 25 39 84 78 Fax 03 25 39 84 90 Email france pok fr Web www pok fr DOC 1963 EN Rev A 28 08 2013 Coryright POK SAS Coryright POK SAS DOC 1963 EN Rev A 28 08 2013 Presenfstion Overview MAR SGA S O O es POK SAS ZI Les Guignons 10400 Nogent sur Seine FRANCE 6 Tel 03 25 39 84 78 Fax 03 25 39 84 90 Email france pok fr Web www pok fr e Construction Weight e 17 21 kg e Hydraulic Data VALEUR Maximum flow rate e 3000 l min a 7 bar e Bride PN16 DN 80 al s e OU e Bride PN16 DN100 Outlet e Filet femelle 2 5 BSP Nominal Pressure e 16 bar Test Pressure e 25 5 bar Vertical elevation Range de 60 a 80 Horizontal elevation range e 360 Body dismountable e No e Elevation range locking pin Safety e Horizontal range locking knob POK SAS ZI Les Guignons 10400 Nogent sur Seine FRANCE Tel 03 25 39 84 78 Fax 03 25 39 84 90 Email france pok fr Web www pok fr DOC 1963 EN Rev A 28 08 2013 Coryright POK SAS Coryright POK SAS DOC 1963 EN Rev A 28 08 2013 Loauyouft 527 mm 444 mm 418 mm POK SAS ZI Les Guignons 10400 Nogent sur Seine FRANCE Tel 03 25 39 84 78 Fax 03 25 39 84 90 Email france pok fr Web www pok fr Usage Instructions Insfelloation
10. he horizontal adjustment knob Mark D 2 Point the monitor in the desired direction by turning the monitor Mark E 3 Tighten the horizontal adjustment knob Mark F Mark D POK SAS ZI Les Guignons 10400 Nogent sur Seine FRANCE Tel 03 25 39 84 78 Fax 03 25 39 84 90 Email france pok fr Web www pok fr DOC 1963 EN Rev A 28 08 2013 Coryright POK SAS Coryright POK SAS DOC 1963 EN Rev A 28 08 2013 Maintensnce e Monitor maintenance procedures To correctly maintain the monitor it is important to 1 Clean the unit with clean water after every use 2 If salt water has been used use clean water to clear out any particles or residue that may damage internal components 3 Do not use any corrosive materials they may damage the gaskets and cause leaks 4 Check the operation of moving parts no part should jam be damaged or be blocked 5 Regularly inspect the unit visually to detect leaks e Greasing the monitor To protect the equipment we recommend that you grease it every six months Connect a grease gun to the friction areas indicated to ensure proper lubrication POK SAS ZI Les Guignons 10400 Nogent sur Seine FRANCE Tel 03 25 39 84 78 Fax 03 25 39 84 90 Email france pok fr Web www pok fr Maintensnce e Returning to service procedure It is important to check the following before placing the equipment back in service
Download Pdf Manuals
Related Search
MERCATOR mercator projection mercator map mercator mercatorum mercator projection map mercator world map mercator projection vs real mercatoria mercator knife mercator chart mercator medical mercator map vs real mercator meaning mercator puzzle mercator projection definition mercatornet mercator ocean mercator projection distortion mercator by citco mercator logo mercator slovenia mercator login mercator gloves mercator bih mercator emba
Related Contents
Samsung S24A450DW triturador bio55 - gasolina trituradora bio55 Multiquip Landscape Lighting GBWE User's Manual User`s Manual (EN) - Avitech International Corporation 平成27年5月1日号(全20ページ)(PDF:8730KB) Ives S48 User's Manual Home Decorators Collection 1997630270 Use and Care Manual Philips RI1832 CD-RW Copyright © All rights reserved.