Home

1 Table of Contents

image

Contents

1. deteriorate to 0 15 mm m between 10 m to 30 m and to 0 2 mm m for distances above 30 m applies for 100 target reflectivity background illumination of approximately 30 000 lux Stanley TLM165 Distance measuring yes Min Max measuring yes Permanent measuring yes Addition Subtraction yes Area yes Volume yes Pythagoras 2 point 3 point Memory 5 results Message Codes If the message Error does not disappear after switching on the device repeatedly contact the dealer If the message InFo appears with a number press the Clear button and observe the following instructions No Cause Correction 204 Calculation error Perform measurement again 252 Temperature too Let device cool down high 253 Temperature too Warm device up low 255 Received signaltoo Change target surface weak measuring e g white paper time too long 256 Received signaltoo Change target surface high e g white paper 257 Too much back Shadow target area ground light 258 Measurement Correct range outside of meas uring range 260 Laser beam inter Repeat measurement rupted Care e Clean the device with a damp soft cloth Never immerse the device in water e Never use aggressive cleaning agents or solvents Warranty The Stanley TLM has a two year warranty For further information on this contact your dealer Subject to change drawings descriptions and
2. Table of Contents Instrument Set up Prohibited use Introduction Hazards in use Overview Limits of use Display Disposal ak Insert batteries Electromagnetic Compatibility EMC FCC statement applicable in U S Operations Laser classification Switching ON OFF Labelling Message Codes Adjusting measuring reference Distance unit setting Multifunctional endpiece Measuring Functions Measuring single distance Permament measuring Add Subtract Pythagoras 2 point Pythagoras 3 point Memory 5 last results Technical Data Warranty Safety Instructions Areas of responsibility Permitted use Stanley TLM165 Instrument Set up Introduction The safety instructions and the user manual should be read through carefully before the product is used for the first time A The person responsible for the product must ensure that N all users understand these directions and adhere to them The symbols used have the following meanings WARNING Indicates a potentially hazardous situation or an unintended use which if not avoided will result in death or serious injury CAUTION Indicates a potentially hazardous situation or an unintended use which if not avoided may result in minor injury and or appreci able material financial and environmental damage Important paragraphs which must be adhered to in practice as they enable the product to be used in a technically correct and efficient manner Overview Dis
3. asuring on roads construction sites etc Deliberate or irresponsible behaviour on scaffolding when using ladders when measuring near machines which are running or near parts of machines or installations which are unprotected e Aiming directly in the sun Hazards in use WARNING Watch out for erroneous measurements if the instrument is defective or if it has been dropped or has been misused or modified Carry out periodic test measurements Particularly after the instrument has been subject to abnormal use and before during and after important measurements CAUTION Never attempt to repair the product your self In case of damage contact a local dealer WARNING Changes or modifications not expressly approved could void the user s authority to operate the equipment Limits of use Refer to section Technical data The device is designed for use in areas permanently habitable by humans Do not use the product in explo sion hazardous areas or in aggressive environments Stanley TLM165 Disposal CAUTION Flat batteries must not be disposed of with household waste Care for the environ ment and take them to the collection points provided in accordance with national or household waste Dispose of the product appropri Y country Adhere to the national and country specific management can be downloaded from our homepage local regulations The product must not be disposed with ately in acc
4. ordance with the national regulations in force in your regulations Product specific treatment and waste Electromagnetic Compatibility EMC WARNING The device conforms to the most stringent requirements of the relevant standards and regulations Yet the possibility of causing interference in other devices cannot be totally excluded Safety Instructions FCC statement applicable in U S This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential instal lation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful inter ference to radio communications However there is no guarantee that inter ference will not occur in a particular instal lation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interfer ence by one or more of the following measures e Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an expe
5. play F On Measure Tracking Area Volume Pythagoras Memory Measuring AND TA Clear Off reference Unit Stanley TLM165 Instrument Set up Display Battery Area Volume M i 7 ung ed El 8 Info max min Min Max A Measuring Insert batteries Pythagoras Lo Memory OOOO rin afetetete i Addition Subtraction Units Main line Stanley TLM165 To ensure a relia ble use do not use zinc carbon batteries Change batteries when battery symbol is flash ing Operations Switching ON OFF T OFF CLEAR 2 sec Device is turned OFF Adjusting measuring reference D a gt Distance is measured from the front of the device Distance is measured from the rear of the device standard setting E Undo last action Message Codes If the info icon appears with a number observe the instruc tions in section Message Codes Example o S 256 penni is measured from the pin of the endpiece Stanley TLM165 Operations Distance unit setting UNITS Switch between the a following units K 2 sec 0 000m 0 00 1 16 0 in 1 16 Multifunctional endpiece Stanley TLM165 Measuring Functions Measuring single distance Target surfaces Measuring errors can occur when meas uring to colourless liquids glass styrofoam or semi per meable surfaces or when aiming at high gloss s
6. rienced radio TV technician for help Laser classification Labelling Laser Radiation Do not stare into the beam Laser class 2 acc IEC 60825 1 2007 Maximum radiant power lt 1mW Emitted wavelength 620 690nm Beam divergence 0 16 x 0 6 mrad Impulse duration 0 2 x 109s 0 8x 10s a The device produces visible laser beams which are emitted from the instrument Itis a Class 2 laser product in accordance with IEC60825 1 2007 Radiation safety of laser products Laser Class 2 products Do not stare into the laser beam or direct it towards other people unnecessarily Eye protection is normally afforded by aversion responses including the blink reflex WARNING Looking directly into the beam with optical aids e g binoculars telescopes can be hazardous CAUTION Looking into the laser beam may be hazardous to the eyes Attach the laser sticker a of your country language Stanley TLM165
7. technical data Stanley TLM165 Safety Instructions The person responsible for the instrument must ensure that all users understand these directions and adhere to them Areas of responsibility Responsibilities of the manufacturer of the original equipment Stanley Tools 701 E Joppa Road Towson Maryland 21286 www STANLEYLASERS com www STANLEYTOOLS com www STANLEYTOOLS eu The company above is responsible for supplying the product including the User Manual in a completely safe condition The company above is not responsible for third party accessories Responsibilities of the person in charge of the instrument e To understand the safety instructions on the product and the instructions in the User Manual e To be familiar with local safety regula tions relating to accident prevention Always prevent access to the product by unauthorised personnel Safety Instructions Permitted use e Measuring distances Tilt measurement Prohibited use e Using the product without instruction Using outside the stated limits e Deactivation of safety systems and removal of explanatory and hazard labels e Opening of the equipment by using tools screwdrivers etc e Carrying out modification or conversion of the product e Use of accessories from other manufac turers without express approval Deliberate dazzling of third parties also in the dark Inadequate safeguards at the surveying site e g when me
8. tion acti vates automatically Minimum or Maxi mum measure ment Aim laser at lower point Measuring Functions Memory 5 last results lt 5x a 5 last results are 7 displayed Navigates trough 5 last results Stanley TLM165 Technical Data Distance measurement Typical Measuring Tolerance 1 5 mm 0 06 in ance Maximum Measuring Toler 3 0 mm 0 12 in Range at Target Plate 50 m 164 ft Typical Range 40 m 132 ft Range at unfavourable condi 35 m 115 ft tion REEK Smallest unit displayed 1 mm 1 16 in laser point 6 30 mm at distances 10 50 m Laser class 2 Laser type 635 nm lt 1 mW Protection class IP54 dust and splash water protected Autom laser switch off after 90 s Autom power switch off after 180 s Battery durability 2 x AAA up to 3000 measure ments Dimension H x D x W 104 x 58 8 x 29 6 mm 4 25 x 2 31 x 1 17 in Weight with batteries 100 g 3 53 oz Temperature range Storage Operation 25 to 70 C 13 to 158 F 0 to 40 C 32 to 104 F applies for 100 target reflectivity white painted wall low background illumination 25 C applies for 10 to 500 target reflectivity high back ground illumination 10 C to 50 C Tolerances apply from 0 05 m to 10 m with a confi dence level of 95 The maximum tolerance may
9. urfac es Against dark surfaces the measuring time increases The last value mea WF sured is displayed x Stops permanent measuring a Aim active laser at target Add Subtract 1x 2x The result is shown in the 3 main line and the measured 1 rpg value above This process can be repeated as required The same process can be The next meas The next meas used for adding or subtracting urementisadded urement is sub areas or volumes to the previous tracted from the one previous one Stanley TLM165 Measuring Functions Area NA 1x The result is shown in the main line and the measured P f 2 i value above Ny Aim laser at first Aim laser at sec target point ond target point Volume Aim laser at first Aim laser at sec Aim laser at third target point ond target point target point The result is shown in the main line and the measured value above Stanley TLM165 Measuring Functions Pythagoras 2 point 75 Aim laser at up per point Aim laser at up per point Aim laser rectan gular at lower Aim laser at rec tangular point The result is shown in the main line and the measured distance above Pressing the measuring key for 2 sec in the function activates automatically Minimum or Maxi mum measurement Stanley TLM165 The result is shown in the main line and the measured dis tance above Pressing the meas uring key for 2 sec in the func