1. before shipping in compliance with U S Department of Transportation DOT regulations How to Contact APC Refer to the APC Web site www apc com Limited Warranty American Power Conversion APC warrants its products to be free from defects in materials and workmanship for a period of two years from the date of purchase Its obligation under this warranty is limited to repairing or replacing at its own sole option any such defective products To obtain service under warranty you must obtain a Returned Material Authorization RMA number from customer support Products must be returned with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase This warranty does not apply to equipment that has been damaged by accident negligence or misapplication or has been altered or modified in any way This warranty applies only to the original purchaser who must have properly registered the product within 10 days of purchase EXCEPT AS PROVIDED HEREIN AMERICAN POWER CONVERSION MAKES NO WARRANTIES EXPRESSED OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Some states do not permit limitation or exclusion of implied warranties therefore the aforesaid limitation s or exclusion s may not apply to the purchaser EXCEPT AS PROVIDED ABOVE IN NO EVENT WILL APC BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL OR CONS
2. property of their respective owners EC Declaration of Conformity 2002 We the undersigned declare under our sole responsibility that the equipment specified below conforms to the following standards and directives Standards to Which Conformity Declared EN62040 1 1 EN55022 EN55024 EN61000 3 2 3 3 EN60950 1 Application of Council Directives 73 23 EEC 89 336EEC 91 157 EEC 92 81 EEC Type of Equipment Uninterruptible Power Supply Model Numbers CP15U48 CP24U12 CP40U48 Manufacturers American Power Conversion American Power Conversion APC Suzhou UPS Co Ltd Ballybritt Business Park 2nd Street 339 Suhong Zhong Lu Galway Ireland PEZA Cavite Economic Zone Suzhou Industrial Park a Rosario Cavite Suzhou Jiangsu 215021 American Power Conversion Philippines P R China Breaffy Rd Castlebar i i Co Mayo Ireland American Power Conversion APC Brasil LTDA Lot 10 Block 16 Phase 4 AI Xingu 850 American Power Conversion PEZA Rosario Cavite Barueri 132 Fairgrounds Rd Philippines Alphaville Sao Paulo West Kingston RI 02892 USA 06455 030 Brazil American Power Conversion American Power Conversion 1600 Division Rd Lot 3 Block 14 Phase 3 West Warwick RI 02892 USA PEZA Rosario Cavite Philippines American Power Conversion 40 Catamore Blvd East Providence RI 02914 USA APC India Pvt Ltd 187 3 188 3 Jigani Industrial Area Jigani Bangalore 562106 Karnataka India American Power Conversion
3. to work To utilize the cold start feature use a small pointed object to press the recessed cold start button 6 Chapter 4 Service Contact and Warranty Information Service APC makes every effort to ensure parts and equipment arrive in working condition Occasionally it may be necessary to return parts or equipment that are not in working condition If the UPS requires service follow these steps 1 Contact APC Customer Support through the APC Web site www apc com Note the product model number the serial number and the date purchased If you call APC Customer Support a technician will ask you to describe the problem and try to solve it over the phone If this is not possible the technician will issue a Returned Material Authorization Number RMA If the product is under warranty repairs are free If not there is a repair charge Procedures for servicing or returning products may vary internationally Refer to the APC Web site Select the appropriate country from the country selection field Select Support from the tab at the top of the web page 2 Pack the product in its original packaging m Pack the unit properly to avoid damage in transit Never use Styrofoam beads for packaging Damage sustained in transit is not covered under warranty 3 Mark the RMA on the outside of the package 4 Return the unit by insured prepaid carrier to the address given to you by Customer Support Always DISCONNECT THE BATTERY
4. A P C b v Ballybritt Business Park Galway Ireland Galway Ireland Ray S Ballard Managing Director Europe gt 2 0 E dak 5 Jan 02 N Billerica MA U S A Richard J Everett Sr Regulatory Compliance Engineer Oel f Gene 5 Jan 02 10
5. EQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Specifically APC is not liable for any costs such as lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data costs of substitutes claims by third parties or otherwise Regulatory Approval Paige AY Ou f CE O es ES LISTED 0e N 394 58VA E191450 This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his her own expense Shielded signal cables must be used with this product to ensure compliance with the Class A FCC limits Entire contents copyright 2005 by American Power Conversion Corporation All rights reserved Reproduction in whole or in part without permission is prohibited APC the APC logo and PowerShield are registered trademarks of American Power Conversion Corporation All other trademarks are the
6. WWW apGc co PowerShield User Manual 990 0375G 12 2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications Safety This Safety Guide contains important instructions that should be followed during installation and maintenance of the APC equipment and batteries It is intended for APC customers who setup install relocate or maintain APC equipment Changes and modifications to this unit not expressly approved by APC could void the warranty Failure to observe these warnings may result in serious injury death or damage to the equipment Electrical Do not work alone under hazardous conditions Warnings Servicing this equipment may require working with protective covers removed and utility power connected Use extreme caution during these procedures Check that the power cord s plug s and sockets are in good condition Replacement of fuses or other parts must be with identical types and ratings Substitution of nonidentical parts may cause safety and fire hazards Battery Danger of explosion if battery is incorrectly connected or replaced Use only Warnings APC replacement batteries Specifications Model Input Output Max Battery type Number Signal Same for All Models Current 100 240V 50 60Hz 1 0A 48V 5mA 12V 7 2AHr 15W Spill Proof 100 240V 50 60Hz 1 0A 12V 5mA Maintenance Free 24W Sealed Lead Acid 40W Environmental Specific
7. ad the wall outlet or circuit Status Indicators UPS Front View Status Indicators ZA Green indicates the UPS is on utility power Yellow indicates the UPS is on battery AC power OUTPUT Green indicates DC output power is provided by the battery or utility power BATTERY Red indicates that the battery is not connected or the battery needs to be replaced Refer to the Battery Replacement section Communication Signals The PowerShield communication signals are isolated from its internal circuitry via open collector opto coupled transistors The connection labeled Signal Return is a common return point for all communication signals In the typical application the attached equipment digital ground connects to Signal Return and pull up resistors turn the open collector signals into logic levels Vo Voltage output Ke Voltage output SIGRTNY Signal return ON BATT E Low when operating from utility line Open when operating from battery REPLACE BATT X Low when battery is charged Open when battery fails the Self Test BATT MISSING Low when battery is present Open when battery is missing LOW BATT E Low when battery is near full charge capacity Open when operating from a battery with lt 20 capacity Cold Start Use the cold start feature to apply power to the UPS and connected equipment when the UPS is off and there is no utility power The battery must be charged for the cold start feature
8. ations Operating Temperature 32 F to 113 F 0 C to 45 C Operating Humidity 0 to 95 noncondensing within enclosure Max Operating Elevation 10 000 ft 3 000 m Max Storage Elevation 50 000 ft 15 000 m Storage Temperature 5 F to 113 F 15 C to 45 C Physical Specifications Height x Width x Depth UPS 7 5 x 9 5 x 3 in 19 x 24 x 7 6 cm UPS carton 13 5 x 13 5 x 4 5 in 34 x 34 x 11 cm Weight UPS 7 5 lbs 3 kg UPS with package materials 9 Ibs 4 kg Unpacking Inspect the unit upon receipt Notify the shipping carrier or product supplier if there is damage The packaging is recyclable save it for reuse or dispose of it properly Check the package contents The package contains the enclosure the battery to be installed one power cord one seven pin output connector and product documentation Chapter 2 Installation Enclosure Installation E Aq Install the UPS in a protected area that is free of excessive dust and has adequate airflow 6 Su Do not operate the power supply where the temperature and humidity are outside the specified limits Refer to Specifications in this v x x x manual Install the UPS inside a building in a protected area that is free of excessive dust and has adequate airflow Use screws that are appropriate for the weight of this unit and the mounting surface material Refer to Specifications in this manual Step 1 Step 2 Step 3 Battery Co
9. ver Release Tabs Battery Installation Step 2 Positive Terminal Battery Cover Release Tabs Negative Terminal Battery Replacement This UPS has an easy to replace hot swappable battery Replacement is a safe procedure isolated from electrical hazards You may leave the UPS and connected equipment on for this procedure Replace the spent battery with replacement battery RBC40 See your dealer or refer to the APC Web site www apc com for information on replacement battery modules To replace the battery module refer to Battery Installation above Once the battery is disconnected the connected equipment is not protected from power outages d Be sure to deliver spent batteries to a recycling facility found on the Used Battery Return Facilities list included with the unit Chapter 3 Operation Connect Equipment and Power Utility Power Cord Inlet REPLACE BATT X BATT MISSING LOW BATT SI Communication Signals The UPS battery charges when it is connected to utility power The battery charges fully during the first eight hours of normal operation Do not expect full battery run capability during this initial charge period 1 Connect equipment to the UPS communication signals via the seven pin connector included or use an APC custom data cable must be ordered separately 2 Plug the UPS power cord into the utility power cord inlet and then into the wall outlet NOTE DO NOT overlo