IQTL User Manual

image

Contents

1. Delete Grid S Spot Properties rr Alternatively click the Estimate button iy to have the software calculate a threshold for the current image To do this the software evaluates the volumes of all spots in the image ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA Array 6 6 9 2 Fine tuning the threshold After you make an initial estimate for the flagging threshold you can manually adjust the threshold value so that the presence or absence of the spots as displayed in the Measurements window reflects what can be seen in the Image window To fine tune the flagging threshold either e Type a value between 0 and 100 in the Flagging threshold text box OF e Drag the slider to the left towards 0 or the right towards 100 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 133 6 Array 6 9 Presence Flagging 134 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA Colony Counter 7 7 Colony Counter 7 1 Introducing Colony Counter You use the Colony Counter module to analyse images by detecting and measuring image features 2D spots or colonies You can display and print measurement data from the detected colonies To help you along the way where relevant pictures are included in the section showing what you should expect to see on the screen If you have not already done so you should read Chapter 4 The Common Interface describing the general features of all the modules before using the Col
2. h oO eu oO c x a oO 100 Pixel Position LEE LA ki Note The additional lanes will be visible only in the Experiment Overview mode You can select which additional lanes are displayed on the Lane Selection tab of the Options dialog box Multi channel Images When you use the Channel Overlay viewing mode in a multi channel image only the profiles from the current lane of your selected channels are displayed The relevant coloured line identifies the profile of each channel If the Single Channel viewing mode is selected the lane profile of the currently selected channel is displayed For information on displaying different lanes refer to Section 5 15 Experiment Overview Ne ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 63 5 1D 5 5 The 1D windows 64 Lane Images lower pane This pane shows the images of your lanes The images displayed here relate to the graphs being shown in the upper pane The images are displayed as horizontal rectangles so that the features on the image align with the calculated lane profile If the lane bends on the gel you will see an adjusted image in this pane showing the lane as it would look if it had not bent If additional lanes are displayed in the upper pane their images will also be displayed in the lower pane The lane images are truncated in the lower pane so that they do not extend beyond the star
3. If you have previously generated a Lane report and then change the current lane you need to generate a new Lane report Current In Single Channel viewing mode the current channel is the Channel channel displayed in the Image window In Channel Overlay viewing mode the current channel is the lowest numbered of the selected channels ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 11 5 1D 5 8 Beginning the Analysis 78 5 8 Beginning the Analysis Selecting the Begin Analysis command from the Analysis menu or when restarting the analysis you are given two options You can either analyse the image automatically or stepwise stepping through each tool as desired You can also draw an Area of Interest AOI to be used by the automatic or stepwise analysis modes 5 8 1 Specifying an area of interest AOI To specify an AOI move the pointer over the image in the main image window and drag out a rectangle This area is used when analysing your gel Setting an AOI on noisy gel images can be beneficial when using the automatic analysis mode or when creating lanes To clear the AOI click anywhere on the image 5 8 2 Automatic or Stepwise analysis Analysing the images in Automatic mode performs the modes selected in the Navigator Automatic analysis steps M Lane Creation M Background Subtraction M Band Detection Multi channel Images In multi channel images the automatic analysis steps selected in th
4. Edit Image For more information on the Edit Image command refer to Chapter 4 8 Image Manipulation 60 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 1D 5 5 2 3 Analysis menu The 1D analysis tools are discussed in the following sections e Section 5 8 Beginning the Analysis ere Begin Analysis e Section 5 9 Lane Creation Lane Creation Background Subtraction e Section 5 10 Background Subtraction Band Detection i Molecular Size Calibration in 1D Quantity Calibration Normalization Section 5 11 Band Detection Experiment OVveryviela Annotate Image Create Lane Report e Section 5 12 Molecular Size Calibration e Section 5 13 Quantity Calibration e Section 5 14 Normalisation e Section 5 15 Experiment Overview e Section 5 16 Creating a Lane Report For information on the Annotate Image tool refer to Chapter 4 4 Annotations 5 3 Toolbar The toolbar is located below the main menu bar For more information on the use of the standard toolbar buttons refer to Chapter 4 7 Toolbar The various other tools used in the 1D module are located in the Navigator with the exception of the Create Lane Report command which is only available from the Analysis menu 54 Window Selector bar The Window Selector bar is located below the Navigator It contains buttons to activate the Image Second Image Analysis Measurements Graph and Report windows used in the 1D module Imag
5. ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA The Common Interface 4 4 5 2 Colour The options available in this dialog box allow you to modify the colour scheme used in the Image windows The Preview shows a thumbnail of the entire image and displays the effects of any changes Colour Scheme x Preview Multi channel Images When using multi channel images you can only launch the Colour Scheme dialog box when in Single Channel viewing mode The colour that you choose from the colour scheme drop down list is used to display every channel in Single Channel viewing mode In Channel Overlay viewing mode every channel has a pre defined colour scheme that cannot be changed The choice of colours used to display each channel is dependant upon how many channels there are in the image 2 Channel images 1 green 2 red 3 Channel images 1 blue 2 green 3 red 4 Channel images 1 blue 2 green 3 yellow 4 red Ma ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 29 4 The Common Interface 4 5 Contrast and Colour 30 Colour Scheme List This is a drop down list box containing the names of all of the installed colour schemes on the system Grey Scale Coomassie Blue Silver Stain PseudoColour PseudoColour Blue Green Yellow Fed Of the various colour schemes that are supplied with the software two are false colour schemes these can be useful for visualising fai
6. Print scale Images can be printed using one of two scaling methods Fit to the page Scaled fico C Actual size Report format Page setup for tables The settings on this tab affect the Copy to Clipboard and Copy to File commands from the Edit menu Changing the area to be copied from an image 1 Click either Visible area of the image or Whole of the image 2 Click Done to confirm your choice You can specify how much of a current image window should be printed and at what scale Changing the print range and scale 1 Specify the print range of the window to be printed by clicking either Visible area of the image or Whole of the image 2 Select the scale from the Fit to paper Actual size or Scaled options If you click Scaled select or type the percentage in the text box Note The default is set to 100 of the original size 3 Click Done to confirm your choices ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA The Common Interface 4 Report Format This feature is only available in the 1D module For more information refer to the Report format button in Section 5 6 5 Reporting tab in 1D Page setup for tables Clicking the Page setup for tables button displays the following dialog box Margins Preview Let RER Right 1 13in Top 1 50in Bottom 1 50 in Titles and GridLines M Row Headers M Column Headers dis Page Order Center on Page M Vertical Lines Fir
7. Lane Notes Click the Edit Lane Notes command to display the Lane Notes dialog box that allows you to enter notes for detected lanes For more information refer to Section 5 16 1 Adding Lane Notes ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 59 5 1D 5 2 Main Menu Bar Description Instruction Lane Selection Clicking Edit Lane Selection displays the Select Lane dialog box which contains a list of all the lanes in the current gel Select Lanes The Analisis window can show more than one lane at once The lanes on display and the order in which they are shown can be selected here cence arm From this list you can select which lanes will be used as the additional lanes for viewing in the Analysis and Measurements windows You can also set the order of those lanes by clicking the up and down arrows 1 To select all the detected lanes from the list click the Select All button 2 Ifyou only want to display lanes from a specified tier in the image click the Select tiers button El and then select the required tier from the menu Select All Tiers Tier 1 py Tier3 3 Then select the required lanes for the chosen tier 4 Alternatively you can select individual lanes by selecting the check box to the left of the lane The order of the lanes only affects the information shown in the Analysis Measurements and Report windows You can clear the selected lanes by clicking the Deselect all button
8. If you have already performed Normalisation and then start entering data in the Quantity Calibration mode you will be asked if you want the Normalisation information to be deleted When you activate the Quantity Calibration mode new controls appear in the Parameter tab of the Navigator The results of band calibrated volume assignment can be viewed in the tables of the Measurements window You can also view the shape of the calibration curve in the Graph window Ensure that you have the Calib Norm Volume and Band Percentage Calib Norm table fields selected in the Options dialog box The tables will then show the Quantity calibrated volume and the Band Calib values respectively All the bands included in quantity calibration are shown in the Image window with yellow band diamonds those that are not included have blue diamonds Yellow and blue are the default colours The default colours can be changed in the Image tab of the Options dialog box ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 105 5 1D 5 13 Quantity Calibration 106 5 13 1 Assigning known volumes Band volumes are added and edited from the Image window Multi channel Images To perform Quantity Calibration on multi channel images ensure that you are using the Single channel viewing mode the calibration values and colours will not display in the Channel Overlay mode You must set Quantity Calibration standards for each channel these settings w
9. Rectangle The rectangle shape allows you to measure any rectangular area on an image Click the Rectangle button LI and drag to create a rectangle Polygon The polygon shape allows you to measure any polygonal area on an image Click the Polygon button Z position the pointer where you want to start the first side of the polygon and click Continue dragging and clicking to add new points to the polygon When you have completed the polygon right click to add the final point which connects the line back to the first point closing the polygon Ellipse The ellipse shape allows you to measure any elliptical area on an image Click the Ellipse button Le drag out an area Closed Spline To create a closed spline click the Closed spline button S and then use the same method as for creating a polygon the only difference is that the points are connected by a smooth curve instead of a series of straight lines ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA Toolbox 8 Grid 1 Click the Grid button to display the Grid Dimensions dialog box Dimensions Rows i Columns i 2 Type the number of rows and columns for the grid and then click OK 3 Draw out a grid over the image Each cell is measured independently and displayed in the Area window Autotrace To perform autotrace 1 Click the Autotrace button ci and then click the Parameters tab to display the following dialog box Autotrace Parameters Edge pi
10. The procedures in this section offer basic examples of how to analyse images You can fine tune your analysis using of the various editing tools To help you pictures are included in the section showing what you should expect to see on the screen If you have not already done so you should read Chapter 4 The Common Interface describing the general features before using the 1D module The 1D module is supplied with an image data file of previously saved data When following the procedural steps you can restore the image used in this section that describes the various features To restore the image click Help Restore Default image 5 2 Main Menu Bar Many of the menus are standard across all of the modules within ImageQuant TL In the 1D module the exceptions are the File Edit and Analysis menus 5 2 1 File menu The following list of File menu commands are discussed in Chapter 4 3 Main menu bar e Open Image Fie Open Image Ctrl 0 e Invert Measurements ee eee Save Preferences Image Pro pe rties Invert Measurements Image Properties e Print Print Ctrl F Print Setup Pri nt Setu p Pil Preen Printing Options Exit e Print Preview e Printing Options e Exit ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 57 5 1D 5 2 Main Menu Bar The remaining commands are discussed as follows Description Instruction Load The Load Preferences command allows you to load a Preferences personal
11. 30 98158 46075 98009 0 5832 98322 46025 97097 0 0 96843 45775 96791 6493 98645 70678 98159 0 0 98278 121395 98434 nn 991 ARQ72 90274 All Spots Fi Below each table field you will see a column of data for each spot of the chosen channels Y ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 119 6 Array 6 5 Options 120 6 4 4 Array Second Image window The Second Image window facilitates the viewing of the individual channels of a multi channel image As with many of the other windows this window has its own toolbar For more information on the tools refer to Chapter 4 11 3 Second Image window 6 5 Options When vou click the Options button on the toolbar or click View Options the Options dialog box for Array appears The Reporting tab is common to all modules but the other tabs have parameters specific to Array 6 5 1 Array s Image tab The parameters shown in the Image tab relate to the display in the Image window By clicking the check boxes vou can change the display for the various labels in the Image window Image Tables Reporting Overlay options Different types of information can be shown over the spots in the image F Show spot numbers Show annotations Spot colours Spots are displayed using different colours to indicate selection and other properties ommal Excluded from analysis Reference defines normalisation Spot Colours To change a
12. 5 When you click the Normalisation button after selecting your bands the band and lane number will be displayed in the Navigator depending upon how many bands are chosen To deselect a band position the pointer over the band When the pointer changes to right click to deselect the band The software updates the quantity calibration curve and the measurements tables To delete all the normalised values click the Clear button at the top of the Navigator 5 15 Experiment Overview Experiment overview is the last step in the analysis sequence Clicking the Restart button allows you to revisit and refine your analysis In this mode the Navigator displays the various mode buttons In the 1D module the Parameter tab provides controls for the display of lanes in the Analysis window Display Lanes Current only C Overlaved Stacked i Lane Selection To change the display of lanes in the Analysis window 1 Ensure that the Analysis window is visible 2 Select which lane or lanes you want to display by clicking the Current only lane Overlayed lanes or Stacked lanes by clicking a button 3 You can select additional lanes to be shown by clicking the Lane Selection button This displays the Select Lanes dialog box For more information refer to Lane Selection in Section 5 2 2 J b i Clicking the Restart button Festart a message box advising you that all the analysis of the current image will by reset and you will
13. 82 82 4 e Norway T 47 815 65 777 F 47 815 65 666 e Portugal T 21 417 7035 F 21 417 3184 e Russia CIS amp NIST 7 495 956 5177 F 7 495 956 5176 Spain T 902 11 72 65 F 935 94 49 65 e Sweden T 018 612 1900 F 018 612 1910 Switzerland T 0848 8028 10 F 0848 8028 11 e UK T 0800 515 313 F 0800 616 927 e USAT 1 800 526 3593 F 1 877 295 8102 imagination at work 28 9175 41 AA 05 2007
14. Molecular Size of material that would migrate there ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 167 9 Glossary of Terms 168 Object This can be a Line or Shape used to define an area or subtract background values in the Toolbox module On the Fly The software automatically re measures data or re plots a graph when any detection changes are applied to images Palette table of colours that allows you to change the colours used to display an image Rather than specifying particular colours directly images can be drawn by referring to particular entries in this table Therefore if the palette is changed the image colours changes This often gives the impression that the image itself has changed when this is actually not the case The software adjusts the colours to give you different displays of image contrast without changing the image Pixels A pixel an abbreviation of Picture Element is the smallest part of a digitised image and is the unit of quantification A digital image is simply a two dimensional array of pixels In a greyscale image each pixel contains a measurement of the image at that point whereas in a Binary Monochrome Image the pixel is an on off switch that indicates whether the system believes that there is a Band at that position There will be many pixels to an individual band Rf Rf Retardation Factor is a measurement of the position along the lane relative to its length By default the
15. Options dialog box Note Theexperimentcan store information from either the Quantity Calibration mode or the Normalisation mode If you have already performed Quantity Calibration and then start entering data in the Normalisation mode you will be asked if you want to delete the Quantity Calibration information Multi channel Images To perform Normalisation on multi channel images ensure that you are using the Single channel viewing mode The Normalisation values and the coloured diamonds that identify the bands will not display in the Channel Overlay mode You must set Normalisation volumes for each channel these settings work independently of the other channels in a multi channel experiment Each channel can have its own Normalisation volumes or its own Quantity Calibration standards and settings because the analysis modes can be applied to the independent channels You can apply a mixture of analysis modes to the channels within the multi channel image but you cannot apply both analysis modes to any one channel ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 109 5 1D 5 14 Normalisation 110 Because calibration is performed on a per channel basis you must select the individual channels and click the Normalise button in the Navigator This rule also applies when you want to clear the normalisation volumes from the channels by clicking the Clear button ae 5 14 1 Choosing Bands and Normalising Normalisation requi
16. a smaller size select a point in a detected colony and right click This reduces or deletes the colony pixel by pixel Unlike the drawing commana if you connect the finish point to the start point of the area you want to erase the software does not erase the entire area 7 7 3 Deleting Colonies To delete a whole colony as opposed to part of a colony 1 Click the Delete Features button Ex in the upper Navigator 2 Position the pointer over the image 3 Select the colony to be deleted and click A red cross appears to the right of the pointer when it is over a colony The software removes the detected colony from the image window but not from the original image file You remain in deletion mode until you select another mode 7 7 4 Splitting Colonies This option allows you to split larger detected colonies 1 Click the Split Features button Ay i the upper Navigator 2 Position the pointer over the colony that you want to split The pointer changes to a scalpel 3 Click and drag the pointer in any direction i e vertically horizontally or diagonally to split the colony If the colony is too small it might be deleted rather than split ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA Colony Counter 7 7 7 5 Renumbering Detected Colonies After any editing you should re number the detected colonies by clicking the Renumb button _Renumb in the Navigator By selecting a row of colony data from the Measurements
17. band s peak To perform band detection click the Band Detection button in the Navigator Alternatively click Band Detection from the Analysis menu AR With the Band Detection mode activated click the Detect button _ Jin the Navigator and the Minimum slope parameter slider appears ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 93 5 1D 5 11 Band Detection 94 Multi channel Images When you perform band detection or edit bands in multi channel images you must use the single channel viewing mode Band detection is performed on a per channel basis Any parameters set are only applied to the current channel Therefore each channel has its own set of band detection settings This rule also applies when editing bands any editing is made to the current channel Ne 5 11 1 Automatic Band Detection Automatic band detection uses a series of algorithms to find the peaks in the profile to declare as bands and the troughs between them to declare as edges Although this method is classed as automatic some parameters still need to be specified 1 Enter or change the peak detection parameters using the Parameter tab or at the top of the Navigator Note You can set or change the minimum slope parameter using the slider or for a more precise figure type a value in the text box 2 Try different values to see which provides the best results A good starting point is Minimum slope 100 Noise reduction 5 and Percentage maxi
18. be able to start again ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 111 5 1D 5 16 Creating a Lane Report 112 5 16 Creating a Lane Report After completing your analysis you can create a lane report By default a lane report contains information on the gel image and the analysis methods applied plus any information concerning the scanning of the gel image Multi channel Images You must select the Single channel viewing mode before generating a lane report for a multi channel image The lane report includes the multi channel image name current channel number and the lane number No 1 Set the Image area and Print scale in the Options Reporting tab Image Analysis Tables Lane Selection Reporting Image area When printing of copying an image You can choose how much of the image you want f Visible area of the image Whole of the image Print scale Images can be printed using one of two scaling methods f Fit to the page Scaled fico Actual size Keep test and lines at 1 1 in the Image Window Report format Fage setup for tables ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 1D 5 2 Click the Report format button and set the report format in the Reports dialog box Report format S af Different types of information can be displayed in the Report iCal Include report logo loaded from file defautlogo bmp Browse W Show the following
19. be displayed using different colours Colonies 0O Current colony E Cancel Apply Image and Colony display By clearing the Show Image check box the gel image of the experiment will only be visible in the Zoom window and the Image window will display only the detected colonies after the detection has been performed You can hide the detected colonies in the Image window by clearing the Show Colonies or Show Current Colony check boxes The four choices on the Colony Style list are Standard Outline Crosshairs and Bullets Colony colours To change colours click the coloured box next to the item to launch the Color dialog box Select a new colour and click OK ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA Colony Counter 7 7 5 2 Tables tab in Colony Counter You use the tables tab to define which data fields you want to display in the Measurements table To select a data field click the box adjacent to the field name Change their order by highlighting a field and clicking the up or down arrows at the right of the list Image Tables Reporting Detecting Table fields The table in the Measurements Window can show different 7m data fields These can be selected from the list below Colony Number Coordinates Volume Volume Background Background Area Average Intensity Circularity Cancel Apply For more information on the available data fields and t
20. first position in each lane has an Rf of O and the last has an Rf of 1 There is a linear increase in Rf from start to finish Rolling ball This is an automatic background subtraction method The method calculates the background as if a ball with the radius you specify were rolling underneath the profile Rubber band This is an automatic background subtraction method It can be thought of as stretching a rubber band underneath the lane profile Single view mode Displays an individual multi channel image in the Image window Spike Spike is the term used for a small dark artefact within a spot This can result from for example dust or errant bits of labelled target ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA Glossary of Terms 9 Spin buttons These are small buttons at the side of a text box that allow you to increment or decrement a parameter by a set value Standard Lanes A lane with known values of Molecular Weight or pl for its bands Step wedge translucent film divided into steps of known diffuse density Step wedges are used in Intensity Calibration to provide areas of an image that can be used to calibrate all pixel intensities Tab control that allows you to switch between multiple views for example the different panes in the lower Navigator or the various settings of the Options dialog box Text box Text boxes allow you to enter numeric values for parameters The text box will turn yellow if
21. folder where the Shape object file is stored and then select the Shape object file Click Open The object appears on the current image and can be moved if required Select All This command is used to select all the objects that appear on the image 150 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA Toolbox 8 Invert Use this command to reverse objects that are selected and selection those that are not For example if you have three objects drawn on the image and one of them is selected applying this feature selects the remaining two objects and deselects the originally selected object You can then for example move the object s to a different area or change the properties of the selected object s Shape Use this command to define the properties for the current Properties object For more information refer to Shape Properties in Section 8 6 3 Edit Image Click the Edit Image button on the toolbar to display the Image Editor dialog box You can manipulate the image by rotating it or applying filters This feature is common to all the modules For more information refer to Chapter 4 8 Image Manipulation 8 2 2 Analysis menu Analysis Shape Definition Background Subtraction Command Description Experiment Overview Annotate Image Shape The shape definition command is used to quantify a section Definition of the image by selecting an object and applying it to the image For more informati
22. from your computer and automatically enters the information into the completed form The information can be deleted from the bottom of the e mail or physically cut from the bottom of a printed form if you do not want this information disclosed The system information is used solely to assist our Technical Support and is kept confidential About Displays the name and version number of the software together with the registration information 20 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA The Common Interface 4 4 4 Annotations Using the Annotations mode you can add text labels with optional arrows to precisely locate and identify certain areas of an image You activate the Annotations mode es e by clicking the Annotate button Annotate on the main toolbar or e by clicking the Annotate Image command on the Analysis menu After you click the Annotate button the Navigator pane changes to show the font and parameter options You can create an annotation on a single image or multi channel image to highlight a particular area of interest There is no limit to how many annotations you can create in any one image or channel Multi channel Images Annotations can be created and displayed in multi channel images regardless of the number of channels or the current view mode However it should be noted that you can only create one set of annotations per multi channel image Mo ImageQuant TL 7 0 User Manual 28
23. main use is to detect a colony that might consist of more than one colony vy Colony Number The unique number given to a N N Y N detected colony Colonies are numbered from top left to bottom right across the selected area If a detected colony is deleted or partially deleted during the analysis the colony number is eliminated In the case of a partially deleted colony the remainder of the colony is issued with a new identification number at the bottom of the list To identify any detected colony position the pointer over the colony and wait a second or two for the number to appear Comment Displays the text you typed into the data field Coordinates Equivalent to the centre of the Y Y Y N detected mass with the coordinates rounded to the nearest integer Height Shows the height in pixels of the N N N Y bounding rectangle of the shape Lane Percentage A measure of the Bands Volume Y N N N divided by the Volume of the whole Lane Max Intensity The maximum pixel intensity in a N N N Y given area ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 53 4 The Common Interface 4 6 Options DR Median Intensity The median pixel intensity in a given area Min Intensity The minimum pixel intensity in a given area Mode Intensity The most common pixel intensity for a given area Molecular Size Shows a band s molecular size with the units shown in the table column header Name The name of the sha
24. more information refer to Section 4 8 Image Manipulation Channels Click the channel buttons to select the channel or oo channels that display in the main image window Each channel of a multi channel image enables a button Channel C3 La ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 39 4 The Common Interface 4 8 Image Manipulation 40 4 8 Image Manipulation You should perform all image manipulation before analysing the data in this software This includes any rotation cropping or alignment of the images that may be necessary However the software includes a set of tools that allow you to make basic modifications to the images Care should be taken when using these tools ifthe images have already been analysed in an experiment because manipulating the image could result in the loss of data Multi channel Images All editing actions performed on a multi channel image will apply across all channels E Clicking the Edit Image button Eat mage opens the Image Editor Alternatively from the Edit menu click Edit Image 4 Image Editor C Program Files fl_tamral ds Zoom to Fit Be Es File Image Marker Zoom B G0 DOIG ole EUSA SS RKKK The Image Editor provides tools to Remove Noise Crop Rotate and Flip the image ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA The Common Interface 4 4 8 1 Image Editor window The Image Editor window has its own toolbar LE GO
25. of type All ImageQuant TL image files tif tiff gel Cancel Analyse this image using VV Preview E 1D for analysis of many types of 1D electrophoresis gel 3 Preview not available To open an image 1 Select the folder from the Look in list 2 Select All ImageQuant TL files tif tiff gel img from the File of type list ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 55 4 The Common Interface 4 15 Keyboard shortcuts 3 Click the specific image file from those displayed 4 Select the desired analysis module from the Analyse this image using list 5 Click Open The selected image automatically opens in the relevant modules Image window allowing you to analyse the image If you select the Preview check box a preview of the file displays in the small pane If the image does not display in the Image window after the module has opened click the Image window button on the window selector bar below the Navigator 4 15 Keyboard shortcuts Each menu is activated by clicking the Alt key and the appropriate underlined letter e g File Menu A t F Below is a table of common menu commands and their shortcut keys Menu command Shortcut File Open Image Ctrl O File Print Ctrl P Edit Export to Clipboard Ctrl E Help Contents Ctrl F1 56 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 1D 5 5 1 Introducing 1D ImageQuant TL 1D is the gel or TLC plate analysis module
26. preference file A preference file contains the settings you choose using the Options dialog box such as the colours to Identify different aspects of an image the lane attributes or the reporting features Each user of the analysis software can select and save a set of preferences This avoids users having to reset their preferences and allows different users display and analysis preferences to be stored concurrently Loading a different preference file to that currently in use invalidates and deletes any previous analysis that has been performed on the current image Save To save your display preferences Preferences 1 Select all your preferences for such things as image display and reporting using the Options dialog box You can also select Annotation preferences Click File Save preferences and type a filename Alternatively you can select a filename from the displayed list of existing files If you select an existing filename that file will be overwritten with the currently selected preferences The program automatically locates the Preferences folder in which to save the file 3 Click Save 5 2 2 Edit menu The following list of Edit menu commands are Ew discussed in Chapter 4 3 Main menu bar Export to Clipboard CtE Export to File Export to Bere e Export to Clipboard Export Lane Objects Import Lane Objects e Export to File Export Lane Profile to Clipboard Export Lane Profile to File e
27. tee non bte ni 68 MOOD Ne nn Rens 68 POI IS OO Re ind 70 FOIS TOO AMD SSSR nn 73 Lane Selection taO siiin Nan 74 Reporma tao D enar N TO A 75 The current experiment lane and channel n s Te Beginnino tne ANGIS S isinen a 78 Specifying an area of interest AOI u s 78 Automatic or Stepwise analysis 78 LORS CT AUOM nr ne ee nes 79 OU ERE E ON E I E E de On 80 Creating an Area of interest AO 81 Creating Lanes Automatically oo ceecccescsessssessssessssesssessssecsssesssessssecssessssecsses 82 Drawing Lanes Manually sssssssssssesisissssssssssssssssssrsrrirssrsesssssssssrsrrenn 83 ERON OLOTE o SR scoala E date 83 Har cane MAT aaee in E AA en 88 D lOUAO LONES ic iain ae AS 89 BOCKOFOUNG SUDUFACHOMI ND axes coer an nas 89 Automatic Background Subtraction Methods in 1D 90 Manual Background Subtraction Methods 91 Band DEtECHON ad ised UUs corres O N 93 AULOMGIC BAN De COLE a den 94 Edge Detection Parameters sardines 95 Manual Band Editing in the Image window 96 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 4 5 11 4 Manual Band Editing in the Analysis window ssscsssssssseccsseecsseecsseee 98 5 12 Molecular SIZE Calpa sen aa uns ruse 100 5 12 1 Applying Values To Standard Lanes 107 5 12 2 Choosing parameters and performing calibration 102 5123 sEOHING Standard Mappings Lists nan nan 103 Slede FAUNI StONOOIOS manieri a A R 104 S13 Guant
28. the Colony Counter module 7 4 The Colony Counter windows After starting the Colony Counter module the screen displays the relevant windows for this module 3 Colony Counter Colony_Spots tif File Edit View Analysis Window Help S g A e D CA Open Export Print Preview Annotate Contrast Colour Options Edit Image e x 5 Image Window Colony_Spots_tif Zoomed to Fit Detect Clear Sensitivity _ Operator Size Initialise Sensitivity Area Of Interest Circle Previous Next You can display any of the windows by clicking the relevant button on the window selector bar below the Navigator The windows of the Colony Counter module are discussed in the following sections ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA Colony Counter 7 7 4 1 Colony Counter Image window This window displays the gel image 68 Image Window Colony _Petri tit Zo Me ES upon which you can detect and edit the colonies Scroll bars are located at the bottom and right side allowing you to scroll through your data The Image window has its own toolbar For more information on the tools refer to Chapter 4 11 1 Image window 7 4 2 Colony Counter Zoom window You see an overall view of the image and a rectangle containing the zoomed area of the gel in the Image window Oy Zoom Window Of X 7 4 3 Colony Counter Measurements window The Measurement window displays the data in a table forma
29. the corresponding area in the Image window Note No rectangle appears if the Image window displays the whole image ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA Array 6 6 4 3 Array Measurements window The Measurements window displays the analysis results Three different tables of data are available Current Grid Selected Spots and All Spots Each table can be viewed by clicking the corresponding tab at the bottom of the window sus Measurements Window Spots 96 spots 1214902 AF1 For each table you can select different data fields to display the various properties of the spots You select and order the data fields using the Tables tab of View Options Data within a column can be sorted by clicking the column header The arrow at the top of the column indicates the order in which the data is sorted Multi channel Images You can view data from the current channel of a multi channel image when using the Single Channel viewing mode as you would for an individual image This rule applies to all the tables of the Array module To display data for all channels of a multi channel image select the Channel Overlay viewing mode In the example below the All Spots table displays channels 1 and 4 934 8 98436 46622 99071 00 96825 45892 96365 10 53 96794 45760 96795 31262 108846 186120 105193 14544 103206 133588 102038 0 0 96799 46552 96867 0 0 96819 45741 96833 15 10 99634 45788 100688 35
30. the lane or too close to another grimace in the lane The grimace appears as a horizontal line with red handles to the left and right sides You can move these handles to adjust the line to match the angle of the band and you can add handles to make the line bend to match the curvature of the band ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 87 5 1D 5 9 Lane Creation 88 To add a handle to the grimace 1 Position the pointer over the grimace line The pointer changes to T 2 Click to add the handle and drag the handle to reposition it 3 Toadjust a grimace handle position the pointer over the handle The pointer changes to 4 Drag the handle to reposition it To delete a grimace right click on the handle The effects of the grimaces can be seen in the Analysis window after you accept the changes The profile and lane image change according to the new calculations 5 9 6 Half Lane Width After you draw the lanes you can resize selected individual lanes or the lanes within a multibox Whichever edit method you choose multiple lanes or single lanes from the list in the Navigator you use the half lane width editing tool This editing tool allows you to set the width of a lane in pixels What you are doing Is setting the half width of the lane If you set the value to 9 the lane width will be 18 pixels with 9 pixels on either side of the central point of the lane All lanes in a multibox will be resized to th
31. the lanes so that the calculated band volumes represent the volume of the material in the band rather than the volume of all material including the gel material at that position You start the Background Subtraction mode from the Analysis menu or from the Navigator The various methods of background subtraction can be selected by clicking a button in the Parameters tab of the Navigator You choose between four automatic and two manual methods of background subtraction which are described below Multi channel Images The chosen method of background subtraction is applied simultaneously to all channels of a multi channel image Y ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 89 5 1D 5 10 Background Subtraction in 1D 5 10 1 Automatic Background Subtraction Methods in 1D To use the automatic background subtraction methods select the relevant button from the list in the Navigator to perform the subtraction To perform automatic background subtraction 1 Click the button for the method you want to use The software updates the data automatically 2 Check the calculations by viewing either table of Selected current lane or Comparisons all lanes in the Measurements window The background subtraction methods are Background Description Instruction subtraction method Rubber Band This method can be thought of as stretching a rubber band underneath the lane profile If the values at the ends of the profile
32. the way where relevant pictures are included to show what you should expect to see on the screen If you have not already done so you should read Chapter 4 The Common Interface describing the general features of all the modules before using the Toolbox module 8 2 Main Menu Bar The main menu bar of Toolbox is the standard menu bar for all the modules with the exception of the Edit Analysis and Object menus 8 2 1 Edit menu Multi channel Images The Undo and Redo commands are applied to all channels of a multi channel image Undo Create Rectangle 4 Ctr z Command Description Redo Move Rectangle 1 Ctri Y Use this command to undo the last action taken in sequence Cut Ctrl ous ae the action can be Create Delete Move Edit or Properties Duplicate Ctrl D Delete Del Use this command to redo the last previously undone action Export to Clipboard Cu taken in sequence the action can be Create Delete Move Export to File Baa toed Edit or Properties Export Shapes Import Shapes Cut Use this command to cut a line or shape from the active Select AI Chris Image window Invert Selection Shape Properties Alt Enter Edit Image ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 149 8 Toolbox 8 2 Main Menu Bar Copy Use this command to copy the line or shape selected in the active Image window to the clipboard The copied line or shape can be pasted into another position on the im
33. then applies this as the background for the spot The background is therefore calculated independently for each spot This method is the recommended because it usually provides a good localised background intensity and is relatively tolerant of noise in the image ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 129 6 Array 6 7 Background Subtraction in Array 130 6 7 4 Negative Controls The Negative Controls method averages all the pixels inside the flagged spots in the grids and applies this average as the background intensity You identify the spots that should be considered as background intensity This method can be useful in microplate analysis where certain spots have been set as controls and are therefore known to contain no material 1 Select the spots you want to change by either clicking on them or drag a selection rectangle around the spots in the Image window Notice that the grid over your selection changes to green identifying it as the current selection To select more than one group press the CTRL key while dragging over the additional groups 2 Click either Set negative control or Deselect negative control button in the Navigator Notice that the software updates the data in the Measurements window automatically 6 7 5 Image Rectangle The Image Rectangle background method requires you to specify a rectangular area of the image This area is then averaged to calculate the background intensity This
34. to a report 1 Select a Lane from the list Edit the notes for Lane 2 gt Cancel 2 Type the additional notes for the selected lane in the text box below the list 3 Repeat the above steps for each desired lane and then click OK The software saves the notes which can be edited at any time using the Lane Notes dialog box Only the notes for the current lane appear in the lane report 114 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA Array 6 Array 6 1 Introducing Array You use the Array module to analyse microplate images gridded arrays and dot and slot blot images The Array module uses a tool based approach to analysis Each tool has a specific task in the analysis process from defining the spots to normalising their measurements and flagging absence and presence The analysis process involves a number of different steps that you can perform these in any order repeating or skipping steps when necessary The procedures provided in this section are basic examples of how to analyse images You can fine tune your analysis using the various editing tools If you have not already done so you should read Chapter 4 The Common Interface describing the general features of all the modules before using the Array module The Array module is supplied with example image files The image used in this section describing the various features can be restored if you want to follow the procedural steps To restor
35. used as the additional lanes for viewing in the Analysis and Measurements windows You can also set the order of those lanes To select all the detected lanes select a Pier i ne au All Lanes from the list then click the Select button If the image has tiers and you only want to display lanes from a specific tier in the image you can select the tier from the list and then click Select Alternatively you can select individual lanes by selecting the check box to the left of each lane Note The order of the lanes only affects the information shown in the Analysis and Measurements windows ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 1D 5 6 5 Reporting tab in 1D Image Analysis Tables Lane Selection Reporting Image area mi When printing or copying an image you can choose how r much of the image you want Visible area of the image Whole of the image Print scale Images can be printed using one of two scaling methods Fittothepage Scaled fico C Actual size F Keep text and lines at 1 1 in the Image Window Report format Page setup for tables The Image area and Print scale parameters set in this tab are common to all the modules as is the Page setup for tables dialog box For more information on these general parameters refer to the Chapter 4 6 3 Reporting tab Report format button Clicking the Report format button displays the Reports dialog box that allo
36. window to the clipboard Print 3 Click the Print button to send the data from the 5 active window to the default printer Fl Preview E Before printing you can preview the desired e image or data By clicking the Preview button the active window changes into a print preview window Refer to Section 4 3 1 File menu for more information Annotate Click the Annotate button to activate the Fra annotation mode which allows you to highlight features of interest on your images or to add text to the image Refer to Section 4 4 Annotations for more information Contrast Click the Contrast button to display a dialog box aD that provides a number of ways to alter the brightness and contrast of an image For more information refer to Section 4 5 1 Contrast Colour Click the Colour button to display a dialog box ene that allows you to change the colour scheme For more information refer to Section 4 5 2 Colour 38 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA The Common Interface 4 Command Toolbar Description Button Options Click the Options button to display the Options Se dialog box which contains various tabs that allow you to select settings for the analysis modules Alternatively select View menu Options For more information refer to Section 4 6 Options Edit Image A Click the Edit Image button to open the Image ie manipulation dialog box that allows you to edit the displayed image in various ways For
37. 6 6 3 Deleting a grid type If not already displayed click the Parameters tab to display the parameters for the Spot Definition mode then follow these steps 1 Select the grid from the list 2 Click the Delete button below the list 124 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA Array 6 6 6 4 Repositioning spots Individual spots or a group of spots can be repositioned in one of the following ways Repositioning the whole grid To reposition the whole grid 1 Click the Create and Stretch Grid button in the Navigator 2 Position the pointer over any of the spots and then drag the grid to the new position All the spots must remain within the image for the new grid position to be accepted To cancel repositioning the grids right click whilst dragging or press the Esc key Moving a small group of spots To move a small group of spots 1 Click the Move and Resize Spots button in the Navigator 2 Drag from the top left to bottom right to highlight the group of spots by drawing a green outline covering the spots Note To select more than one group press the CTRL key when dragging over the additional spots 3 Position the pointer over the selected spots and drag the spots to the new position Moving a single spot To move a single spot 1 Click the Move and Resize Spots button in the Navigator 2 Position the pointer over the desired spot and drag the spot to the new position ImageQuant TL 7 0 Use
38. 6 7 Background Subtraction iN ATOY ssssssssssssssssssssrssirssirrerrerierrrrrssrssss 128 6 7 1 Providing para meto S miiia NEOA 129 6 7 2 SOOE SUNACe MINIMUM HR te anne ane 129 6 7 3 SOLE AVE TRES RE TANS 129 6 7 4 Negone C OnT ONS arrie a a RA EEEO AEN 130 6 7 5 Made Rectang e sa ee A E N N a 130 6 7 6 MORE A T N ae a AO T 131 Ores INCE OISE Rene ne ra ttle a eae he 131 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 5 GI Presence ICING es EET 132 6 9 1 Making QU AAIIGH estima Crisstsi Bass anh tarnish en Na ere 132 6 9 2 Fine tuning the threshold same 133 Colony Counter PIMAIN OQUCINg COON COUNTOR ei eerie ee aed ns 135 7 2 ACUTE GEE cae RE ne lt td 135 To IACOW SCVECION DAN adze aera Re 136 To Th COlOny Counter WINGOWS sieves each hee Rue 136 Gd Colony Counter Image window seessssessssesssssssesssssssssssssecsssscssesesseesees 137 7 4 2 Colony Counter Zoom window 137 7 4 3 Colony Counter Measurements window 137 To ODUN aaea T a NTA 138 7 5 1 Image tab in Colony COUnNtEr ssssssssssesesssssssrrirrsssssssssssssssrsrrsrrrrrrrsss 138 7 5 2 Tables tatin Colony Counte esa E 139 7 5 3 DOCS SR a ie 140 7 6 DETECHION SR RR 141 7 6 1 pasic Dereci onr Melo an au 141 7 6 2 Seno TC ON ONTOCCLS NUS ANS 142 Valk EE CITNAGD SLE CIOO COO OS sn ur nues 143 LA Drawing Undetected Colonies ss 143 Te EROSING CONE vast acted nich A 144 Tiled Deleting COMES nn siad Conan Made 144 7 7 4 DNA COI OC
39. 9175 41 Edition AA 21 4 The Common Interface 44 Annotations 22 4 4 1 Manual Annotations To change the annotation style you click the Parameters tab in the Navigator The parameters tab contains a variety of options For example to change the font click the Font button Aa near the top of the Navigator When you change the annotation style using the Navigator pane the changes you make are applied to all annotations that are presently selected 4 4 2 Adding and Editing Annotations in the Image window The following section describes how to use the mouse and keyboard to Add Move Select and Edit the text of annotations in the Image window Multi channel Images Annotations can be viewed and edited in both single and overlay modes We assume that you are using the default settings for annotations when doing the following actions ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA The Common Interface 4 Adding an annotation To add an annotation to the image shown in the image window 1 Position the pointer over the location in the Image window that you want to annotate The pointer should be the standard arrow indicating that you are not over any other items in the window 2 Left click to add an annotation box An anchor arrow appears with an attached text entry box pointing to the location 3 Type your text into the text entry box 4 Press ENTER to accept the text or press Esc to stop editing withou
40. DIN OS ES E EO 42 4 8 6 DS IA ATTIC CIS AL RS AURA Antenne ne un 43 4 8 7 Rotating IMOO S rm non ne an de 45 4 8 8 PUD DIAGEO MO AR dedans 45 4 8 9 Fitenng R NALE MR a M E de 45 48 10 Changing the Contrast and COURS 46 Agl gt LOOMMIG ON IMAGE oae nnna T E 46 4 9 NOVIO OTOT manean cr eer en ec esterase cr rao tere Crr te nt UENO 47 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 3 4 10 4 11 4 11 1 4 11 2 4 11 3 4 11 4 4 12 4 13 4 14 4 15 Dick 5 2 3 5 4 55 5 5 1 5 52 5 5 3 5 5 4 RoRo 5 5 6 5 6 5 6 1 5 6 2 5 6 5 5 6 4 5 0 5 if 5 8 5 8 1 562Z 5 9 SII 5 9 2 59 5 5 9 4 595 5 9 6 5 97 5 10 5 10 1 510 2 SLT 5 11 1 5 11 2 5 11 3 The ANOIVSIS TOONS Le A ON neste 50 the Program WINGON SL TEA 51 MAJE WINTON iinis Ei 51 Measurements Area WINAOW ss sssssiissseirisssrirssserireesrresssrrresserrsssserrssns 53 Second MODS wma W iasi an 54 S GROWING WIC OWS an OE E 54 WV OW SCIOCIOl DOTE ns rene Sn ne e Elian 55 US 6 Gemeente RE enna a Ree ect ta ene Sennen en 55 COD NIAO ANIMATEUR ee 55 REVO OCP GSO GUUS exci Re S 56 aid get G oll a jbl ll ess RS AR Nu NU ar 57 Man Meni BOF ESS td 57 TOOD Oera a a 7 61 WINQOW S8leCIO DAS ASUS Ness ee 61 MELD WIJOWS Hs EE 2e Ne ns ne 62 PO IPMODOMANAOME nn dan tan 62 PD ANOV MIO one 63 1D Measurements WINGOW 2 sas nhenntintinl 65 LD GI ODA MINOR Eea a AU En 67 TAD ROD ORE MINE en tan nn nan 67 1D Second Image MINOR UE Ne 67 OD ICING nn
41. Export to Excel Lane Notes Lane Selection Edit Image 58 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 1D 5 The remaining menu commands are discussed as follows Description Instruction Export Lane The Export Lane Objects command allows you to save a file Objects containing information on the current lanes 1 Click Edit Export Lane Objects to display the Save as dialog box 2 Select the storage folder and type a filename 3 Click Save Import Lane The Import Lane Objects command allows you to import a Objects file containing information about analysed lanes Click Edit Import Lane Objects to display the Open dialog box Select the folder and filename Click Open The Lane information is applied to the current image If the current image already has lanes a message appears advising you that the existing lanes will be deleted before importing the lanes Export Lane 1 Click Edit Export Lane Profile to Clipboard to export the Profile to numerical values of the Current Lane profile as shown in Clipboard the Analysis window to the clipboard Paste the values into another application Export Lane Click the Edit Export Lane Profile to File command to Profile to File copy the file The Copy to Text File dialog box displays the default folder as the software installation folder 2 Type the filename 3 Click the Save button to save the file containing the numerical values of the current lane profile
42. GE Healthcare ImageQuant TL 7 0 Image Analysis Software User Manual ED GD m y Contents 1 Introduction did Welcome TO MOG COUGIIE TE se SNS nn 9 2 MAU SEMIN CW ince sraetcck shea ts E et aa 9 2 Getting started Bele ARO CTMCGN SUD DON Se SU Sc R 11 ZA Fami IS SOURS ONT meirat A 11 As SSUARUSOTIW ORO modile e a ner 11 3 Multiple Channels ON ET EN rerren ernet eee tuT err neon TR 13 3 2 Processing a Multi channel IMAGE o oeeeesessseessessssesseesseesstessseesseesseen 13 5 Displaying Multichannel Mages ss ss ses 13 3 4 Analysing Multi channel images ou ccccccssesssssssessssesseessessesseeesseesseen 14 Bo IMUII CRONNeLR DONES Sn dr aacbe rea ichaah tae 14 4 The Common Interface AN AC OMI O CONIC MIA ed Le 15 ht Teman WOOW gamer en nent a dd nd 15 DS NINTENDO DL LR tht eect dd nl hal 16 CE M AO ONE ER 2 Ra Rd de dt asada 21 4 4 1 Manual Annota OMS send nude 22 4 4 2 Adding and Editing Annotations in the Image window 22 AS Contrast and Colau serras a un 26 4 5 1 CONTOS SR ne en nn reer 26 4 5 2 COOU aaa E RE 29 AO ODTOM R RE A ad os ou 31 4 6 1 HOG CO A A 31 4 6 2 TOOS COR RSR einai amie de arens 31 4 6 3 REDON OO SE de 36 A TOODO Se ue ne ct 38 48 HIMOSMOANPUIQHGNEL SR LR us A ren nt 40 4 8 1 mage ENOFWIROOMWE RS in htm Ni te 41 4 8 2 Opening images for editing RAA MEN 41 4 8 3 Savno tne CONES IMITO saone 41 4 8 4 POU CPG CSC INC uone aE A e ANNI 42 4 8 5 GO
43. HIZO Adding new standards 1 To create a new standard mappings list click the Create new standard button amp The software creates a new standard with a default name and automatically places you in the renaming mode for that standard 2 Rename the new standard by typing the new name while the original text is highlighted Changing the name of an existing Standard 1 Select the standard you want to rename from the list and then click the Rename button Al below the list Alternatively right click on the selected standard and choose the Rename command from its context menu 2 With the original name highlighted type the new name of the standard mapping list To cancel this action either press ESC to cancel editing without making changes press ENTER or click outside the entry box to accept the current changes 3 You can duplicate the currently selected standard by clicking the Duplicate button This creates a copy of the standard and places you in the renaming mode allowing you to type a new standard name ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 103 5 1D 5 12 Molecular Size Calibration 104 4 Note You cannot edit the pre defined standards but you can duplicate them and then edit the copies to suit your specific requirements You can delete a standard by selecting it and clicking the Delete button x 5 12 4 Editing Standards You can edit standards that appear in blue zaj although you c
44. Lane Objects 59 Invert colours 26 30 measurements 16 selection 151 L Lane Creation 79 creating lanes automatically 82 172 creating lanes manually 83 editing lanes 83 removing an area of interest 81 renaming lanes 79 selecting an area of interest 81 setting tiers 80 Lane Images 64 Lane Notes 59 Lane Profiles 63 Lane Selection 60 Line window 154 Load Preferences 58 M Maintaining aspect ratio 71 Measurements window 65 119 137 Menu analysis 18 61 117 151 edit 18 58 116 149 file 16 57 help 20 main bar 16 object 152 view 19 window 19 Molecular Size Calibration 100 applying values 101 choosing parameters 102 editing mapping lists 103 editing standards 104 Multiple Channels analysing 14 displaying 13 overview 13 processing 13 reporting 14 N Naming lanes 69 Navigator 47 clear button 47 help pane 48 next button 47 parameters pane 49 previous button 47 restart button 48 Normalisation 1D 109 Array 131 O On the fly detection 140 Opening images for analysing 55 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA forediting 41 Options 31 1D 68 70 Array 120 Colony Counter 138 data fields 32 printing 17 reporting 36 table 31 Toolbox 156 P Pasting 18 59 116 150 162 Performing densitometry 83 Preferences saving 58 Presence Flagging 132 fine tuning 133 making an estimate 132 Printing 17 options 17 preview 17 setup 17 Profile scale selecting 72 Q Quantifyin
45. PO GIG EN From this toolbar you can set markers rotate the image select a channel and choose how to view the channels This window also has a menu bar File Image Marker Zoom Zoom in Zoom out Zoom 1to1 Zoom to fit Crop to area Rotate clockwise Rotate anticlockwise Flip Horizontal Flip vertical Filter Contrast Colour The features on these menus are discussed in later sections 4 8 2 Opening images for editing From the Image Editor File menu click Open to display the Load a Gel Image dialog box Select an image and start editing 4 8 3 Saving the edited image When you have performed image editing you can save the edited image by clicking File Save as If you choose to save over an existing file you will be asked for confirmation Editing cannot be undone after saving the image Refer to Section 4 8 4 Reverting an image for more information ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 41 4 The Common Interface 4 8 Image Manipulation 4 8 4 Reverting an image If you are not satisfied with your editing you can restore the image to the original state when you last loaded or saved the image Click File Revert to undo all editing in the current session to an image or channels The Revert command cancels all editing across all channels Editing cannot be undone after saving the image 4 8 5 Cropping images To reduce disk usage and speed up analysis of your image
46. S a daim 144 FRS Renumbering Detected Colonies ss 145 7 7 6 Ceanno All COONS ann nantais 145 7 8 Background Subtraction in Colony Counter wees 146 7 8 1 image Rectangle methot aerae ATA 146 7 8 2 Mode OT non spot metha ursii a Nen e 147 7 8 5 MONO ae D a D IS EONS OTT OEE 147 7 8 4 Clearing DOCK GTOUNG Valu CS A ne Late tie 147 Toolbox Bel EF OCMC IIC i OOOO ES RSR SU RS ee aie 149 8 2 Mair Ment BOr reer NA ae 149 8 2 1 E A ne ne 149 8 2 2 PGI SIS MENU an TT EE 151 8 2 3 OGECEMERU hni a Saket a su ne 152 BS lt WVINGOW selector DOT sieer iea ee 153 84 TAE MOGIDO MS WING OWS RS ue 153 8 4 1 Toolbox SIMACCe WIRCOW asec RE Ra se 155 8 4 2 Toolbox Second Image window 154 8 4 3 TOCIDOX ZOOM WNION ER crac RSR Ra 154 8 4 4 7001008 LNE WINO OW arr re aan nan 154 8 4 5 TOO OKE ACO WOW es TEE IE 155 oho MM DOS it a A it 156 8 5 1 Tables LOOT TODOR Le Li inde 156 8 5 2 Ated Wina OwW TOO ets RS et ON 156 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 8 5 3 ROM AGO AGO TE TE do eus 8 5 4 Reporting TOO ID TODIOON a nt 86 SHODSWETINITON es veuves en nn ne 8 6 1 AOA S SR ARR UE A SA SN eu 8 6 2 SR amt pore ene ONO OM ee ea WT et es en ee 8 6 3 OCEAN a A unset 8 7 Background Subtraction in TOOIDOK then 8 7 1 Background subtraction MmeNOS nana 9 Glossary of Terms ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA Introduction 1 1 Introduction 11 We
47. Tables Lane Selection Reporting Table fields The tables in the Measurements Window can show different v data fields These can be selected from the list below Calib Norm Volume la ay Band Percentage Calib Norm Band Index TX Coordinate Y Coordinates Position Volume Volume Background Peak Height Peak Background x The Selected All Lanes and Comparisons tables available in the Measurements window show the same selected data fields across all tables Ensure that you display the desired table in the Measurements window before selecting the check box adjacent to a data field to display the data For a full list of the available fields and their definitions refer to Chapter 4 6 2 Tables tab ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 73 5 1D 5 6 Options 74 5 6 4 Lane Selection tab The Lane Selection tab contains a list of all the lanes in the current gel Image Analysis Tables Lane Selection Reporting Lane selection Baa The Measurements Window and Analysis Window can show Oe a selected group of Lanes These Lanes can be selected by clicking on the check box next to the lane s name jLane 2 iLane 3 V Lane 4 jLane 5 jLane 6 jLane 7 Lane 8 gt Select all Lanes Deselect All From this list you can select which lanes will be
48. User Manual 28 9175 41 Edition AA 51 4 The Common Interface 4 11 The Program Windows The Image window toolbar The Image window contains a toolbar with the following buttons Description Instruction Zoom 1 1 14 Adjusts the magnification of the image to its original size Zoom to Fit F Clicking the Zoom to Fit button if the image is zoomed fits the image to the size of the window The Zoom to Fit button counteracts any magnification made on an image using the zoom button a which is located in the bottom right corner of the Image window Zoom al You will also find the zoom button Al in the Analysis and Line windows of the various modules In these windows the button toggles with the Zoom to Fit button undoing any zooming effects To zoom the image 1 Click the zoom button 2 Position the pointer on the area you want to zoom 3 Drag the pointer over the desired area Alternatively click the zoom button then left click to zoom in and right click to zoom out Pressing Esc on your keyboard cancels the zoom mode Magnify i Allows you to magnify specific parts of an image Click the magnify button Position the pointer over the part of the image you want to magnify The pointer changes to a small magnifying glass a Hold down the mouse button The area under the pointer appears in a box Drag the pointer to view other areas 52 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA The Common Interface 4 Desc
49. a Note This feature is not available in the Colony Counter analysis module the equivalent feature Reverse colours is in its Colour dialog box ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA The Common Interface 4 Preview Edit sample area The Preview Edit sample area displays a thumbnail of the entire image If the image displays a rectangle on it Known as the area of interest AOI the palette is calculated from the AOI area The default rectangle covers the entire image You can change this rectangle by clicking and dragging out a new rectangle this causes the image to update immediately This feature can be very useful when editing very faint parts of the image as you can set the AOI to a very small area which produces a very good colour standard in this area Image Histogram The Image Histogram displays the frequency with which each pixel intensity occurs within the area of interest The peaks on the graph represent the pixel intensities that occur most frequently within the current area of interest The left and right red bars on the graph show the range of pixel intensities in the image that will be mapped to different colours in the display image You can directly modify the brightness and contrast of the display by dragging the bars on the graph o Counts a502 Moving these handles closer together increases the contrast and vice versa The figures below the image histogram represent the scale of the g
50. age or onto another image Paste Use this command to paste the cut or copied line or shape into another position on the image or onto another image in the same position The software resizes the line or shape if the scale of the image is different Duplicate After you draw an object on the image for example a Polygon you can duplicate the object and place a copy ina new location You can reposition the object in a new location on the image and the software calculates that area Repositioning an object Position the pointer over the outline of the object The pointer changes to showing that you are in the correct position Left click to display the handles of the object Drag the object to the new location and then release the mouse button Delete Use this command to delete a selected line or shape in the Image window Export to These are common features to all the modules Clipboard File For more information refer to Chapter 4 3 2 Edit menu or Excel Export Shapes Having created a specific object you might want to apply it to another image Before applying an object to an image you must save it by exporting it 1 Click Edit Export shapes to display the Save As dialog box 2 Select a folder or create a new folder type a filename and click Save The export file is saved as a Shape Object file with an obs extension Import Shapes Click Edit Import Shapes to display the Open dialog box Select the
51. ages As with many of the other windows it has its own toolbar For more information on the tools refer to Chapter 4 11 3 Second Image window 8 4 3 Toolbox Zoom window The Zoom window displays an overall view of the image highlighting the area shown in the Image window with a rectangle The display in the Image window will scroll to match the new position of the highlighting rectangle when dragged to a new location 8 4 4 Toolbox Line window This window displays the analysis of line objects Multi channel Images To display data for the current channel of a multi channel image select Single Channel view mode e Each plot on the graph has the same A Line Window CE colour as the line it represents in the Image window To change a line colour refer to Shape Properties in Section 8 6 3 Intensity 2 3 Position the pointer over the graph in the Line window The pixel position on the graph is highlighted in the Image 2 3 4 5 Pixel Position window 200 154 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA Toolbox 8 8 4 5 Toolbox Area window This window displays the measurements for the area objects sus Area Window To select different table fields and change their order use the Table Fields page of the Options dialog box The Name and Comment of an area object can be edited using the Properties dialog box Multi channel Images To display data for t
52. ailable space The lower the number the less space each lane takes up and the larger the gaps between lanes will be Lanes are automatically aligned If the automatic detection has failed for any reason click the Clear button in the Navigator and draw the lanes manually ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 1D 5 If you want to perform densitometry on the bands ensure that the lane boundary edges you draw closely follow the lane 5 9 4 Drawing Lanes Manually To draw the lanes you set the parameters in the Navigator 1 If the image displays distinct sections set the Number of tiers 2 Set the Number of lanes you want to draw 3 Setthe Lane width This specifies how much of the width of each section should be converted into a lane since it is unlikely that there will not be a gap between them You are now ready to draw lanes manually 1 Draga rectangle over the gel image in the Image window The lanes appear and each lane is formed from the shape and position of the corresponding section Because the rectangle contains multiple lanes it is called the lane multibox 2 To add extra lanes to a multibox click the image at the position where you want another lane If you make a mistake click the Clear button and start again This will clear all the lanes 5 9 5 Editing Lanes Whether your lanes were created automatically or manually they can be edited by using the Multiple or single lane editing tools located
53. am from the list 4 Click the average or collective group button uy 5 Click the Normalise button Nemmslise qt the top of the Navigator and check the data displayed in the Measurements table gt 6 When finished click the Next button ext ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 131 6 Array 6 9 Presence Flagging 132 6 9 Presence Flagging Presence flagging allows you to set the level above the background at which the spots should be flagged as having a significant amount of material present The presence or absence of spots can be seen in the Measurements window after you select the Presence Absence data type The basic steps involved in Presence Flagging are 1 Make an initial estimate of the threshold 2 Fine tune the threshold level Multi channel Images Presence Flagging is applied across all channels of a multi channel image You can apply presence flagging parameters in both the Single channel and Channel Overlay viewing mode i 6 9 1 Making an initial estimate The quickest way to accurately define a threshold for flagging spots as having material present is to make an estimate automatically or manually and then adjust the estimate to match what you can see in the image To set the initial flagging threshold either Right click a spot in the image and select either the Define Presence or Define Absence command from the context menu ava Define Presence Define Absence
54. an unacceptable value is entered Toggle To change an item s state between two possible choices normally On or Off ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 169 9 Glossary of Terms 170 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA Index A Activating the software 20 Adding grimaces 87 lane notes 114 Adjusting contrast and brightness 28 Analysing multi channel images 14 Analysis window 63 Annotations 21 adding 23 deleting 25 editing 24 fonts 24 moving 23 24 options 25 selecting 24 Area of Interest AOI 78 81 140 141 142 Area window 155 B Background Subtraction 1D 89 Array 128 Colony Counter 146 histogram peak 165 image rectangle 91 130 146 image rectangle ellipse 165 localaverage 165 local median 165 manual baseline 92 minimum profile 90 mode of non spot 147 negative controls 130 none 91 131 165 rolling ball 90 rubber band 90 spot edge average 129 spot surface minimum 129 Band Detection 93 automatic 94 edge parameters 95 manual editing in the analysis window 98 manual editing in the image window 96 C Changing colony colours 138 Changing colour schemes 30 Colony Detection 141 basic method 141 clearing all 145 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA deleting 144 drawing 143 editing 143 erasing 144 renumbering 145 setting parameters 142 spliting 144 Colour boxes 30 Context menu 24 103 153 163 167 Contrast response curve list 28 Control Cen
55. annot edit standards that appear in red zaj 1 2 If required change the Mapping Units from the list Next add mappings to the mappings list by clicking the Add new mapping button or double click on the last item in the mappings list showing and then start editing Type the value in the text box and press ENTER or click the Add new mapping button again The software adds a value to the list and displays the value in descending order Repeat the above step to add each value If you want to remove a value select the value by clicking it in the list and then click the Delete button x under the mappings list After you have finished editing the standards click the Done button on the Edit Standards dialog box ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 1D 5 5 13 Quantity Calibration The purpose of quantity calibration is to relate the band volume in terms of image intensity to real world values Entering the real world volumes for bands with known values does this From these values the software computes a calibration curve of real world volume against raw volume The real world volumes of the bands with unknown values can then be derived from this curve In the 1D module you can either perform Quantity Calibration or Normalisation An experiment can store information from either the Quantity Calibration mode or the Normalisation mode but not both types of information in the same experiment
56. annotations an outline box appears around the selected text box This outline box does not appear on any image printouts Annotation boxes are not included on report printouts Annotation Fonts Clicking the Select Font Style button displays the Font dialog box that allows you to set the font style for your annotations ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA The Common Interface 4 Delete selected Annotations x The x button deletes any currently selected annotation If you continue to click this button the annotations will all be deleted in the reverse order that they were added There is no undo command If you accidentally delete an annotation you will need to add it again Setting annotation options Located at the bottom of the Navigator is the Annotation parameter tab This tab contains the following options Text outline Select the shape of the border around the text of your style annotations from the drop down list You can select a rectangle rounded rectangle or no border Fill Colour Select the colour for the background of the text area of your annotations from the drop down list This option is disabled if you have chosen a transparent background Line thickness Select the weight of the lines that is used to draw the anchor arrow of the annotations You can choose one of size line thickness or No line If you choose No line your annotation appears as a moveable text box only Colour Select the c
57. are lower than the rest of the profile or the bands are badly separated do not use this method Minimum This method sets the background level as the lowest value Profile found in the profile It is not advisable to use this method where the lowest point is found at the extremities of the lane since the result is dependent on where the lane is drawn This calculation can be hard to repeat between analyses Rolling Ball The Rolling Ball method requires you to enter a value for the size of the rolling ball This method calculates the background as If a disc with the radius you have entered were rolling underneath the lane profile The larger the radius of the disc the less the background rises with the profile This method displays both a slider and parameter entry box 1 Click the Rolling Ball button and a slider and parameter entry box appears in the Navigator Move the slider or enter a specific value in the entry box Although the slider looks as if the maximum parameter is 200 when you move the slider to the right side you can enter larger values for the radius in the parameter entry box up to the maximum value of 10000 3 Click the Subtract button at the top of the Navigator View the calculations in the tables of the Measurements window 90 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 1D 5 Background Description Instruction subtraction method Selecting the None method clears any background subtraction
58. are satisfied with the peak detection parameters that you have entered you are now ready to enter the parameters for edge detection Click one of the following edge parameters using the buttons on the Band Detection dialog box in the Navigator and enter or adjust its value Automatic detection Select this parameter if you want the software to automatically detect the band edges Automatic detection is the preferred method for edge detection The software identifies an edge as the trough in the profile on either side of the band s peak Fixed width If you want to specify the width of each band in pixels thereby determining the position of each edge select the Fixed Width button and enter the required width The band edges are positioned at an equal distance on either side of the peak When you change the edge detection parameters after the bands have been detected you can see the effects immediately The results are shown in the Image and Analysis windows If the results shown do not agree with what you are expecting for example if the software has detected bands that should not be there or if it has not detected enough bands you can either try other parameters or edit the bands manually When you enter different parameters the new band detection results automatically overwrite the previous bands ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 95 5 1D 5 11 Band Detection 96 5 11 3 Manual Band Editing in the Image w
59. area of interest right click anywhere in the image This cancels the area of interest selection allowing you to draw another area ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 81 5 1D 5 9 Lane Creation 82 5 9 3 Creating Lanes Automatically Whether or not the image has distinct sections tiers you can automatically create lanes This is achieved by clicking the Create button in the Navigator After a few seconds the software detects the lanes in the image and draws the lane multibox If the image has tiers ensure that you set the tiers parameter prior to creating the lanes The boundaries of the lanes are shown as rectangles within the multibox area If you are satisfied with the multibox click the Accept button at the top of the Navigator Alternatively you can edit the lanes in the multibox using the procedures below Multi channel Images Every channel is used during lane detection on multi channel images sSS You see the defined lanes and two red multibox edge lines across the top and bottom of the lanes These lines are used to move all the lanes simultaneously See Moving the edges of multiple lane boxes in Section 5 9 5 for more details To move individual lanes see Resizing lanes and Moving Individual Lanes in Section 5 9 5 The large rectangle that appears is split into small rectangles representing the lanes If the Lane width is set to 100 then the lanes use all the av
60. atures of that module 4 9 1 Buttons Clear Previous E Previous Next o gt Mext ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA Clicking the Clear button clears only the analysis effects of the current mode on the image Clicking the Previous button displays the last analysis tool in the Navigator that you used Clicking the down arrow to the right of the button displays a list of analysis modes The list is presented in the suggested order of analysis You can select any mode displayed 4 Previous Background Subtraction Lane Creation Restart analysis Clicking the Next button displays the next set of analysis tools in the Navigator Clicking the down arrow to the right of the button displays a list of analysis modes The list is presented in the suggested order of analysis You can select any mode displayed Background Subtraction Band Detection Molecular Size Calibration Quantity Calibration Normalisation Finish 4 4 The Common Interface 4 9 Navigator Restart 7 After you complete your analysis using the modes Rsstart or you click Next Finish the Navigator displays the Experiment Overview page and the Restart button Clicking the Restart button displays a message telling you that you are about to restart the analysis and asking whether or not you want to continue If you click Yes the current image is cleared of any analysis performed When you select a mode the relevant anal
61. ayed in the Measurements window or Area window of the individual modules The following table shows the data fields available for each analysis module Data Field name Description Array Colony Toolbox Counter The area of the Band Spot Colony or other image feature displaying the number of pixels quantified in the image in order to produce the measurements Area gt Background Area gt Background is the number of pixels which have an intensity greater than the background level Background The total background for the Band Spot Colony or other image feature Background Level The average background intensity in the Image Rectangle used in the background subtraction method of the Toolbox module CE Percentage measure Rte the band s Volume divided by the Total Volume of all the bands in the lane Band Percentage The band s calibrated normalised Calib Norm volume as a proportion to the sum of the calibrated normalised volumes of all the bands in the lane Calib Norm Volume The Calibrated Normalised N Volume of the bands 32 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA The Common Interface 4 Data Field name Description 1D Array Colony Toolbox Counter Centre The X Y position of the centre of a N given shape relative to the top left of the image position 0 0 Circularity A measurement indicating the roundness of a colony 0 1 0 The closer the value is to 1 0 the rounder the colony is The
62. band edge 1 Position the pointer over the band edge you want to move The pointer changes to I 2 Drag the band edge up or down the lane s length You will not be able to move the edge past a band or off the lane or past another band edge 3 Release the mouse button when the band edge is in the required position The Analysis window and Measurements tables update to account for the new size of the band ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 1D 5 If you move a shared band edge a second band edge is created This band edge can be placed between the upper band and the original band edge or between the original band edge and the lower band The bands no longer share a single edge Deleting band edges in the Image window If you have two edges between two bands the bottom edge of one and the top edge of the other you can remove one of these edges The bands share the remaining edge 1 Position the pointer over the band edge you want to remove The pointer changes to l 2 Right click the band The software removes the band and updates the Measurements and Analysis windows Deleting bands in the Image window When you delete a band the software removes the band s peak and any unshared edges from the lane and renumbers the other bands 1 Position the pointer over the diamond shape of the band you want to remove The pointer changes to h l 2 Right click to delete the band The software removes the band and updates t
63. bers above the image You can make any lane a current lane by left clicking on the number in the Image window Molecular size Select the check box to display the molecular size values along the vertical axis Clear the check box if you do not want to display the values Select Tier From the Select Tier list click the tier to view the various ruler options Rulers Font The Font style option displays the font style currently being used by the Image window To change the style click the Change button Change The Font dialog box appears allowing you to change the style and size of the fonts ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 69 5 1D 5 6 Options Description Instruction Colours You can change the colours used by the item for example Current Lane in the 1D module by clicking the colour wells to the right of the item The Colour dialog box appears allowing you to select the colour to be used for the item 5 6 2 Analysis tab You select the Lane and Display attributes from the Analysis tab Image Analysis Tables Lane Selection Reporting Lane attributes You can change the types of information shown for the DN lanes in the Analysis window M Remove background M Show peaks M Show measurements M Show edges Display attributes AAL You can change the way in which lanes are displayed AA inthe Analysis window You can also display multiple lanes M Maintain aspect ratio S
64. calculations This method has the same effect as x clicking the Clear button Clear at the top of the Navigator which allows you to restart your background subtraction calculations 5 10 2 Manual Background Subtraction Methods The manual background subtraction methods are Image Rectangle The average intensity within a rectangular area on the image is taken as the background intensity To use the Image Rectangle method you draw a rectangle in the Image window From this rectangle the background intensity is applied and calculated for all lanes 1 Click the Image Rectangle button 2 Position the pointer over the image window you will see a small white box attached to the pointer 3 Draw a rectangle in a lane from the top left to the bottom right 4 Release the mouse button The calculations are automatically updated in the Measurements window Multi channel Images When you use the Image Rectangle method of background subtraction in a multi channel image the same rectangular region is used across all the channels although each channel uses its own intensity values within the rectangle SS ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 91 5 1D 5 10 Background Subtraction in 1D 92 Manual Baseline The Manual baseline method allows you to define the shape ofthe background line using the profile graph in the Analysis window Multi channel Images The Manual baseline method is only enable
65. d when you use the single channel viewing mode The background for each channel can be edited independently of the other channels in the Analysis window Select the channel then follow the steps defined below IIIa The manual baseline method applies background subtraction to the current lane only This method recalculates the background every time you complete a mouse interaction in the Analysis window Note Ifused incorrectly the manual baseline method can produce erroneous results For good laboratory practice you should use an automatic background subtraction method Using this method produces a straight line with four movable handles along the bottom of the lane profile graph in the Analysis window If you had previously used another method to define the background for this lane the handles fit the current background which will change when you start editing To edit the shape of the background you must either move existing handles small white squares or add additional handles The background line stretches between the handles using straight lines i Ta When the pointer is over a central handle the pointer changes to F if the ct handle is at the start or end of the lane the pointer changes to F To add a handle Position the pointer over the background line between existing handles and then click The software adds a handle at that position ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 1D 5 To
66. e GOOG OUI OM tect SR a en dr 105 513 1 Assigning KNOWN VOUM emma 106 5 13 2 Removing bands from the calibration Curve u ecesseccsssscsssssseessesesseeen 107 5 133 Clearalilcaliprated values ESS RTE AE 107 5 13 4 Selecting the curve type and calibration unit s 111000000000111111 108 SLA NOMOS ON aoe un on 109 5 14 1 Choosing Bands and Normalising inner 110 5 15 Experiment Overview iii 111 5 16 Creating a Lane Report Rs RE M RER 112 5161 Adding Lone NITES srana an dan anna 114 6 Array 61 19 62 6 4 ae 9 ee Es aA ar Leds Visit 115 6 2 MAMA BOT air e e EURER 116 6 2 1 Edie Me onela i E R 116 6 2 2 AnaS S MENU EEEE A CUENTEN 117 Oo VVINGOW Sel Cior OO eaa us 117 OA TREATY WINGOWS seria Ne ru 118 6 4 1 Array Image WINdOW ner 118 6 4 2 ATOY ZOOM WING OW aasia EAA non 118 6 4 3 Array Measurements Window 119 6 4 4 Array Second Image WINdOW sssssssssssssssssiiriirissrrrssssssssssssrsssesn 120 OS OPUNE eaei a A E antenne 120 6 5 1 AnS IMAC IQ Lun EO A 120 6 5 2 POV S FODIOS COD ma MS ut En dater 121 6 5 3 Arrays RCD OUI LO Overs nan nn ons 121 G6 SSO DSTO a hk A en 122 6 6 1 Delimnd TIC gia AVOUT eee aids Socal lanes ahs eagles ne 125 6 6 2 CREOUTIOSG OHO VOC annan a TAA 124 6 6 3 DOIG CUCL 10 ARR Te 124 6 6 4 Repositioning SPOTS he en te te sweetest 125 6 6 5 Adjusting a grid to allow for a skewed image 126 6 6 6 RESIZING SOUS RE Ne Me 126 6 6 7 Eang SOP DOD CIOS ER Re nn dial 127
67. e Navigator are applied to every channel f Click the Automatic button Atomatic to start the analysis After the automatic analysis the Navigator displays the Experiment Overview pane From this pane you can manually perform the remaining modes Molecular Size Calibration see Section 5 12 Quantity Calibration see Section 5 13 and Normalisation see Section 5 14 Alternatively you can perform manual analysis by clicking the Stepwise button Stepwise Performing manual analysis allows you to define the parameters in each mode step by step ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 1D 5 5 9 Lane Creation You use the Lane Creation mode to define the positions and areas occupied by the lanes on the gel image Multi channel Images Lanes will be created for all channels in a multi channel image After the positions and shapes of these lanes are Known you can perform further operations such as band detection Changing the shape of the existing lanes that already contain bands causes an impact on the data Therefore you should to define them correctly in the early stages Adding lanes or bands does not cause a lose of data Before any analysis can be performed you must locate the lanes on the image then you can use the edit tools to resize or move the boundaries until they match the exact shape of the lanes The software automatically numbers each lane when the lane is created You can na
68. e automatically re measures the colonies and updates the Measurements table 7 7 1 Drawing Undetected Colonies 1 Set the Pen eraser size in the upper Navigator 2 Click the Draw or Erase Features button amp Le activate the Draw command The pointer changes to a pen when you move it over the image 3 Position the pointer over the desired drawing area and click or drag the pointer Alternatively if you want to extend an existing colony position the pointer on the desired colony and click or drag the pointer This extends the colony pixel by pixel If you connect the finish point to the start point of the area that you have drawn the software fills the area You remain in the drawing erasing mode until you select another mode ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 143 7 Colony Counter 7 7 Editing Detected Colonies 144 7 7 2 Erasing Colonies Erasing colonies differs from deleting colonies in that the erasing mode erases a colony pixel by pixel and the Deleting colony mode removes the entire colony To erase an entire colony or part of a colony 1 Set the Pen eraser size in the upper Navigator 2 Activate the Erase option by clicking the Draw or Erase Features button The pointer changes to a pen when you move it over the image 3 Position the pointer over the desired area for deletion Either right click an individual colony or drag the pointer across many colonies Alternatively with the pen set to
69. e remains active until you select another feature To select a single object or many objects use either of the following methods e Click on a single object e Press the Ctrl key and click on the outlines of several objects e Drag out an area surrounding all the objects you want to select e With the object or group of objects selected you can then perform any of the following editing commands e Change the properties of the objects e Reposition the objects as a group e Use any of the editing commands cut copy paste duplicate or delete To resize an object you must select the object individually To deselect an object or group of objects press the Ctrl key and click any object or group not required Undo Use the Edit Undo command to undo any object editing for example name size colour or delete This feature allows you to safely experiment with the various methods of editing objects Redo The Edit Redo command allows you to redo any operation that you have previously undone Clipboard Commands While creating shape objects you might want to use the same object several times There are two ways to create a copy of the selected objects e Use the Edit Copy command This places a copy of the selected objects into the clipboard Use the Edit Paste command to paste the selection into another image or back onto the same image e Or create a copy of the selected objects for use on the same image by using the Edit Duplica
70. e spots in the image 1 Click the Parameters tab at the bottom of the Navigator to display the Spot Definition dialog box Grid Type H 10x8 2 Select a grid type from the list in the Parameters _Savweas Dar tab Grid E Columns t 3 Click the Detect button _ D teet_ to create the grid acre 2 automatically or drag a rectangle over the image to create the grid manually Spots M Auto size upon creation Radius E The software automatically measures the spots and TN le Y Radus gJ displays the data in the Measurements window Shape D Circle If you are not satisfied with the detected grid you can edit the grid gt If you are satisfied with the grid detection click the Next button Ne the Navigator changes to the Background Subtraction mode see Section 6 7 Background Subtraction in Array for more information ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 123 6 Array 6 6 Spot Definition 6 6 2 Creating a grid type If not already displayed click the Parameters tab to display the parameters for the Spot Definition mode then follow these steps 1 Set values for the dimensions of the grid columns and rows how many spots wide by spots tall The maximum grid definition is 48 x 32 2 Select the spot shape from the list 3 Click the Save As button to save the created grid 4 Type a name for the grid and click OK The software adds the new grid to the list
71. e the image click Restore Default Image from the Help menu ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 115 6 Array 6 2 Main Menu Bar 6 2 Main Menu Bar Many of the menus contain standard commands or features across all of the modules within ImageQuant TL The exceptions for this module are the Edit and Analysis menus The following sections discuss the commands on these menus 6 2 1 Edit Menu Edit Export to Clipboard Ctri E Export to File gt Epaia Ed Command Description Instruction ae Copy and This feature allows you to copy a grid from one image and x me Paste Grid paste it over another image in the same position elete lan If the image scales are different the software resizes the grid The image that you want to paste the grid over should be of similar size otherwise you might see this message Unable to paste the grid from the clipboard because some of the spots are outside of the image Spot Properties Alt E nter Edit Image After you paste the grid you can use the editing tools in the Navigator to move or stretch the grid Delete Grid This feature deletes the grid displayed on the current image Spot Properties To display the Spot Properties dialog box right click a spot or a cell in the FL E T Measurements window and then click Spot Properties from the context menu Labet Rack CS SS pm YR Q TT nat Spot label Type a label to identify spots in the measuremen
72. e value set for the half lane width when using the Edit Multiple Lanes option To set the half lane width 1 Select either Edit Multiple Lanes or Edit Single Lanes from the list in the Navigator 2 Click a lane to make it the current lane 3 Inthe Parameter tab at the bottom of the Navigator enter a new value for the Half Lane Width by using the spin buttons or by typing a value Note The current lane width is displayed in pixels beside the edit box which allows you to gauge the new value for the width of the lane 4 Click the Apply button D tee Jin the Navigator ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 1D 5 5 9 7 Deleting Lanes When you create a lane multibox you can include lanes that you do not want to use or places where you have left a gap on the gel To avoid these areas being included in the lanes you analyse you can delete them You can also delete individual single lanes in the same way To delete lanes within the Lane Creation mode 1 Click a lane to make it the current lane 2 Press the Delete key on the keyboard or click the Delete Current Lane button x in the Parameters tab of the Navigator 5 10 Background Subtraction in 1D Background subtraction can be performed on the images to account for the background intensity of the gel material on the image Most gel images contain background intensity In effect this is the colour of the gel material This background should be removed from
73. eQuant TL 7 0 User Manual 28 9175 41 Edition AA 61 5 1D 5 5 The 1D windows 62 5 5 The 1D windows After starting the 1D module you should see the Image and Analysis windows displayed for this module In addition you can display the Second channel Measurements Graph and Reports windows Each window is described below 5 5 1 1D Image window The Image window displays the image EREE ETET MIE upon which you are working and is wae em overlaid with analysis information Most of your interaction with the analysis software occurs in this window using the tools located in the Navigator All selection of lanes is performed in this window The Image window has its own toolbar For more information on the toolbar buttons refer to Chapter 4 11 1 Image window ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 1D 5 5 5 2 1D Analysis window The Analysis window consists of two panes Lane Profiles and Lane Images Lane Profiles upper pane WZ Lane 1 100 Current Lane CCE This pane contains a graph that shows the intensity at each point along the length of the current lane or of additional lanes Zooming into an area of interest can alter the range of the axes It is possible to display only the current lane or the current lane and additional lanes This option can be selected in the Analysis tab of the Options dialog box or in the Parameters tab of the Navigator in the Experiment Overview mode to oO
74. edian method determines the median of all the pixel values in the object outline and uses this value for the background Histogram Peak The histogram peak method determines the background of an area by selecting a strip of the area and calculating the modal value of the pixels The value that occurs most often within this area is used as the background value Image Rectangle Ellipse The Image Rectangle Ellipse method requires you to specify a rectangular or elliptical area of the image The mean intensity of the pixels of the area is used to calculate the background intensity Specifying a Rectangle or Ellipse background area 1 Click either the Rectangle LI lor Ellipse button bi the Navigator 2 Drag anarea in the image A dotted line identifies the area with the drawing object sequence number below it E pee ve pau hee ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 165 8 Toolbox 8 7 Background Subtraction in Toolbox Resizing a Rectangle or Ellipse background area 1 Position the pointer over the shape The pointer changes to a two headed arrow when positioned over a handle 2 Drag the handle to a new position At any time while dragging press the Esc key to cancel the action and restore the area back to its original location Moving a Rectangle or Ellipse background area 1 Click a Rectangle or Ellipse boundary area anywhere other than ona a handle The pointer changes to yg 2 Drag the Rectangle
75. ers required either by using the spin buttons or typing the number Number of Tiers 3 2 Lines defining the tier boundaries appear on the image 3 Move the lines between the tiers to their desired locations by placing the pointer on the line splitting the tiers and dragging the lane into position The pointer changes when over the line i 80 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 1D 5 5 9 2 Creating an Area of interest AOI Within the Lane Creation mode you can select an AO to aid the automatic lane creation You select the area from the whole image across a number of tiers or within a single tier The AOI feature can be used to restrict where the software creates the lanes Selecting an Area Of Interest 1 Position the pointer on the image at the location of the desired area 2 Drag out an area on the image as shown in the example below and then release the mouse button 3 The area of interest can be drawn across distinct sections tiers when Ro you click the Create button the ee e s lanes are automatically drawn pe aad according to the number of tiers you set Only one area of interest can be drawn and populated with lanes at any one time If a populated AOI exists and you draw another AOI you must click the Clear button in the Navigator to delete the first populated AOI before you click the Create button to create lanes in the new AOI Removing an Area Of Interest To remove an
76. fields for all the bands in the gel image however the Comparisons table lines up the bands of a similar position in the lanes and displays them in the same row ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 65 5 1D 5 5 The 1D windows Multi channel Images Data for multi channel images in the 1D module displays on a per channel basis The way your data is displayed in each table is dependant upon which viewing mode you are using Single Channel mode Channel Overlay mode 66 When you view multi channel images in single channel mode each table displays data as it would for a single gel image The Selected Lane table displays data from each channel The title bar of the window shows which lane and channel the data originates from as shown in the example below Measurements Window Lane Measurements Lane 4 channel 1 OF x Peak Bkand 6 None 10762349 2258 61 2876 48 112 00 7 74 7 None 10349813 201892 2636 60 128 00 7 45 pi z None 10578055 1804 05 2421 92 144 00 7 61 9 None 9923531 1651 71 226958 128 00 7 14 10 None 101400 32 1635 59 2253 46 160 00 7 30 of iT gt setected Lane AllLanes_ Coma Data displayed in the All Lanes and Comparison tables relate to each channel independently The Selected Lane table displays data for the chosen lane across all channels When you use the Channel Overlay mode the Measurements window identifies each selected channel with coloured blocks Meas
77. g an object 151 Quantity Calibration 105 assinging volumes 106 clearing calibrated values 107 curve type and calibration unit 108 removing bands from curves 107 R Range 16 94 95 110 131 142 Refining your analysis 50 Removing background 70 Report window 67 Reports adding a logo 76 adding a title 76 adding notes 114 copy area 36 multi channel 14 options 36 page setup for tables 37 print range 36 print scale 36 showing analysis parameters 76 Results 53 Reversing colours 26 30 Ruler fonts 69 options 69 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA S Saving automatically 16 cropping rectangles 43 files 18 grid types 124 images 41 lane notes 114 lane objects 59 lane profiles 59 marker configurations 44 preferences 58 toolbox objects 150 Scale 36 72 75 116 Scroll bars 54 Second Image window 54 67 120 154 Selecting tiers 69 Shortcut keys 56 Showing additional lanes 71 annotations 68 bands 68 current lane only 71 edges 71 measurements 71 molecular size 71 overlays 71 peaks 70 Spot Colours 120 Spot Definition 122 adjusting grids 126 creating grid types 124 defining grids 123 deleting grid types 124 editing spot properties 127 repositioning spots 125 resizing spots 126 Spot Properties 116 Status Bar 55 T Technical Support 11 20 Title bar 167 Toolbar image editor window 41 image window 52 main 38 Toolbox aligning objects 152 area objects 158 duplicating objects 150 editin
78. g objects 161 exporting objects 150 importing objects 150 173 W inverting selection 151 line objects 160 moving objects 161 object properties 163 repositioning objects 150 resizing objects 161 selecting groups of objects 152 showing hiding objects 152 ungrouping objects 152 Window selector bar 55 Windows Y 1D 62 analysis 63 area 53 155 Array 118 Colony Counter 136 graph 67 image 51 62 118 137 153 line 154 main 15 measurements 53 65 119 137 overview 51 report 67 second image 54 Toolbox 153 zoom 118 137 154 yellow Edit boxes 49 169 Z Zoom window 118 137 154 Zooming 19 46 174 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 175 176 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA WWW gel ifesciences com GE imagination at work and GE monogram are trademarks of General i i Electric Company ImageQuant and FluorSep are trademarks of GE Healthcare GE Healthcare Bio Sciences AB companies BJ rkg atan 30 Any use of this software is subject to GE Healthcare Standard Software 751 84U End User License Agreement for Life Sciences Software Products A ppsala copy of this Standard Software End User License Agreement is available Sweden on request All third party trademarks are the property of their respective owners All goods and services are sold subject to the terms and conditions of sale of the company wit
79. ge or between the original edge and the right band The bands no longer share a single edge Deleting band edges in the Analysis window If you have two edges between two bands the right edge of one and the left edge of the other you can remove one of these edges The two bands share the remaining edge 1 Position the pointer over the edge to want to remove The pointer changes to 2 Right click the edge The software removes the edge and updates the Image window and Measurements tables Deleting bands in the Analysis window When you delete a band the software removes the band s peak and any unshared edges from the lane and renumbers the other bands 1 Position the pointer over the band you want to remove The pointer changes to hy 2 Rightclick to delete the band The software removes the band and updates the Image window and Measurements tables ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 99 5 1D 5 12 Molecular Size Calibration 100 5 12 Molecular Size Calibration By using the Molecular Size Calibration mode in a gel image containing molecular weight or pl standard lanes you can use the software to establish the molecular weight or pl of the bands Given the known values for these bands on the standard lanes the software can interpolate and extrapolate contour lines of known molecular weight pl horizontally across the gel image If you have run several standards these lines can run between the standards
80. he Analysis window and Measurements tables Deleting a group of bands in the Image window You can delete a group of bands from an area of the gel image For example the bands could be bands that are of no interest or that have been detected in an area of noise by the automatic band detection algorithm 1 Position the pointer to the top corner left or right of the area you want to clear of bands 2 Drag the pointer to the opposite corner of the area The pointer changes to x and an area of red crosshatch x appears over the image while you are dragging the pointer 3 Release the mouse button all the bands below the drawn area are removed and the software updates the Analysis window and Measurements tables ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 97 5 1D 5 11 Band Detection 98 5 11 4 Manual Band Editing in the Analysis window You can add and remove bands in the Analysis window in a similar way to editing in the Image window but you cannot delete a group of bands The following instructions describe performing these actions on the profile graph pane in the Analysis window you can also perform the same interactions with the lower pane Adding bands in the Analysis window To add bands 1 Position the pointer to the location along the profile where you want to add a band The pointer changes to Y indicating that you can add a band at that position The pointer displays a different shape when you are too
81. he Spot Label field Spot Quality Used to highlight any spots of dubious quality that can affect the measurements results Spots thought to contain only noise and spots thought to contain a spike are highlighted Spot Radii Displays the X and Y radii for the given spot These will be identical for square and circular spots Variance The variance of the pixel intensities within a given area Population variance as opposed to the Sample variance Volume The raw volume of the uncalibrated quantity of material in the image feature after the background intensity has been removed Volume The uncalibrated quantity of Background material detected before the background intensity has been removed Width The width in pixels of the N N N Y bounding rectangle of the shape ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 35 4 The Common Interface 4 6 Options 36 4 6 3 Reporting tab The Reporting tab is common to all analysis modules You can customize the way that the content of windows will be copied and printed from the commands in this tab This includes changing the area of an image that will be copied or printed setting the scale at which an image will be printed and changing the way that tables will be printed Image Analysis Tables Lane Selection Reporting Image area TE When printing or copying an image you can choose how much of the image you want Visible area of the image Whole of the image
82. he buttons on the Window Selector bar below the Navigator The windows can be moved and resized they can also be hidden If you are working with a single window it can be maximised giving the largest possible viewing space Discussed below are the windows common to all modules of this software The individual analysis modules also contain specific windows for more information on these windows refer to the relevant module section 4 11 1 Image window The Image window is the most important of the smaller windows and displays the image you are currently analysing The image is overlaid with information determined by the tool you are using and how far through the analysis process you are Most of your interaction with the software is done within this window using the tools located on the main toolbar or Navigator Single viewing mode When in single channel view mode this window works in the same way as it does when a non multi channel image is loaded Multi channel Images Any one of the channels of a multi channel image can be selected and viewed in this window by clicking the channel button on the main toolbar Y Overlay viewing mode In overlay viewing mode any combination of channels can be viewed in this window When in the Overlay viewing mode certain features of the software become unavailable these are specific to the module and mode For more information refer to the relevant analysis mode ImageQuant TL 7 0
83. he current channel of a multi channel image select Single Channel view mode Y ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 155 8 Toolbox 8 5 Options 8 5 Options Click the Options button or View Options to display the Options dialog box The Reporting page is common to all modules The other tabs have specific Toolbox options as described here 8 5 1 Tables tab in Toolbox This tab allows you to select which fields you want to display in the Area Tables rea Window Line Window Reporting window and the order in which you Fields want the fields displayed To display fa eae eee eee list below any of the fields select its check box Click the up and down arrows to Vol Backgr change the order of the selected Total Backar Backar Level fields ViMed Intensity A Avg Intensity Mode Intensity For more information on the 5 D Variance available data fields and their iia definitions refer to Data Fields in Chapter 4 6 2 Tables tab 8 5 2 Area window tab This tab allows you to choose which area objects to display in the Area Tables Area Window Line Window Reporting window Click either Currently Display selected area objects or All area ee chia a as objects You can also synchronise the Currently selected area objects object selection with the table cell or Fe automatically centre an area object Clicking an object s e
84. he pointer changes to 71 3 Atthis point you can add a handle You can drag a handle to make the edges of the multibox more convex or concave to account for differences in lane length or shape ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 1D 5 Moving the edges of multiple lane boxes 1 Click the Move Lane Box Edges button Move Lane Box Edges 2 Position the pointer over the multibox red edge line The pointer changes d to a two headed arrow either vertical Hh or horizontal 3 Drag the line to the desired location and release the mouse button Adding lanes to multiple lane boxes 1 Click the Add Lanes button Add Lanes 2 Click within the multibox where you want an extra lane to appear A vertical lane appears on the image 3 Repeat the previous step as required Adding handles Position the pointer at the location in the lane where you want to add a handle then left click The pointer changes to showing where you can add a handle Note You can drag a handle to a new location at anytime Deleting handles To delete a handle position the pointer over the handle you want to delete The pointer changes to a and right click The lane changes shape to reflect the deletion of the handle Repeat this step to delete all handles not required Bending Lanes 1 Click the Bend Resize button in the Navigator l Bend Resize 2 To change the angle of a lane position the pointer over either the
85. heir definitions refer to Data Fields in Chapter 4 6 2 Tables tab ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 139 7 Colony Counter 7 5 Options 7 5 3 Detecting tab Image Tables Reporting Detecting On the fly detection The on the fly detection method can be used in the detection Navigator page When the user moves the Sensitivity or Operator Size slider but pauses for a short time interval detection will take place but not measurement If on the fly detection is used then it will be applied if the area of interest is less than fi mb Cancel Apply On the fly When you move the Sensitivity or Operator size sliders in the detection Navigator and pause for a few seconds detection takes place this is called On the fly detection By default this feature is selected clear the check box to switch it off AOI size If the Use on the fly detection feature is selected it will only be applied if the area of interest is less than the size displayed in the text box The default size is 1 Mb 140 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA Colony Counter 7 7 6 Detection This procedure describes the basic steps to detect colonies and display measurement data relevant to the detected colonies of the image Detection usually takes place automatically after you change a parameter The results appear in the Measurements window Because of this feature you rarely have to click the Detect b
86. hin GE Healthcare which supplies them A copy of these terms and conditions is available on request Contact your local GE Healthcare representative for the most current information 2007 General Electric Company All rights reserved First Published May 2007 GE Healthcare Europe GmbH Munzinger Strasse 9 D 79111 Freiburg Germany GE Healthcare UK Ltd Amersham Place Little Chalfont Buckinghamshire HP7 9NA UK GE Healthcare Bio Sciences Corp 800 Centennial Avenue P O Box 1327 Piscataway NJ 08855 1327 USA GE Healthcare Bio Sciences KK Sanken Bldg 3 25 1 Hyakunincho Shinjuku ku Tokyo 169 0073 Japan Asia Pacific T 85 65 62751830 F 85 65 62751829 Australasia T 61 2 8820 8299 F 61 2 8820 8200 Austria T 01 57606 1613 F 01 57606 1614 e Belgium T 0800 73 890 F 02 416 8206 e Canada T 1 800 463 5800 F 1 800 567 1008 Central amp East Europe T 43 1 972 720 F 43 1972 722 750 e Denmark T 45 70 25 24 50 F 45 45 16 2424 e Eire T 1 800 709992 F 44 1494 542010 Finland amp Baltics T 358 9 512 3940 F 358 9 512 39439 e France T 01 69 35 67 00 F 01 69 41 98 77 Germany T 0800 9080 711 F 0800 9080 712 e Greater China T 852 2100 6300 F 852 2100 6338 e Italy T 02 26001 320 F 02 26001 399 e Japan T 81 3 5331 9336 F 81 3 5331 9370 Korea T 82 2 6201 3700 F 82 2 6201 3803 Latin America T 55 11 3933 7300 F 55 11 3933 7304 e Middle East amp Africa T 30 210 96 00 687 F 30 210 96 00 693 Netherlands T 0800 82 82 82 1 F 0800 82
87. how Current Lane only M Show molecular size C Show Additional Lanes in Finish mode M Show overlays Profile scale Pixel Position z Command Description Instruction Lane attributes Remove When the software performs background subtraction on the Background gel you see a purple line under the profile graph indicating the line of background If you select the Remove background check box the graph is adjusted so that it shows intensity minus background in its Y axis In addition the image of the lane is adjusted so that it shows a mock up of how the lane would look if it had no background Clear the check box if you do not want to remove the background Show peaks Select this check box to indicate the peaks of bands by a blue arrow over the profile graph and a blue line over the centre of the band in the lane image Clear the check box if you do not want to indicate the peaks 70 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 1D 5 Description Instruction Show Select the check box to cause the area used in volume measurements measurements to be highlighted by a hatched area between the profile and background line between the edges on the profile graph and by a hatched rectangle between the edges over the lane image Clear the check box if you do not want to show the measurements Show edges Select this check box to indicate the edges of your bands by vertical dotted lines under the profile graph and o
88. id 1 C8 Label Size and shape To display the Spot Properties dialog box click the Edit Spot Properties command at any stage during analysis Alternatively adus 4 2j pet right click the selected spot s in the Image Y Radus O it pieis window Shape H E Circle Miscellaneous You can edit the size and shape of spots I Exclude from analysis as well as their labels e g for sample tracking and exclude spots from the ESS Apply analysis Any spots excluded from analysis will not be measured and will not appear in the Selected Spots or All Spots tables ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 127 6 Array 6 7 Background Subtraction in Array 128 6 7 Background Subtraction in Array Background subtraction is the process by which you remove the part of the image s pixel intensity that is background intensity from the measurements Multi channel Images Background subtraction is applied across all channels of an individual experiment ee To begin the process click the Next button in the Navigator when in Spot Definition mode or select the Background Subtraction command from the Next button s menu You can also select this command from the Analysis menu The steps involved in background subtraction are 1 Click the background subtraction method you want to use from the Selected method list in the Parameters tab of the Navigator Selected method Spot Surface Mini
89. in the Navigator for Lane Creation Multi channel Images Editing within a lane or set of lanes is applied across all channels of a multi channel image Editing lanes in a multi channel image can be performed in both the single or overlay viewing mode ee Before using the editing tools you must select the edit mode either Edit Multiple lanes or Edit single lanes from the list in the Navigator ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 83 5 1D 5 9 Lane Creation 84 Editing multiple lanes In the Editing Multiple Lanes mode there are three main tools e Bend Resize Lane box e Moving the edges of multiple lane boxes e Add Lanes After you have added more lanes to a multi lane box you can edit them in single lane mode Editing single lanes In the Editing Single Lanes mode there are three main tools e Bend Resize Move e Add Grimaces Since the lanes might not be straight you can add and move tie points small white boxes called handles You can move a handle inside the lane to bend the lane By default the lane has two handles one at the top and bottom of the lane Extra handles along the multibox top and bottom edges might already have been created if the lanes were automatically created Bending and Resizing lanes in multiple lane boxes 1 Click the Bend Resize Lane Box button in the Navigator U Bend Resize Lane Box 2 Position the pointer over one of the multibox red edge lines T
90. indow In Band Detection mode you can add and remove bands in the Image window you can also move band edges Adding bands in the Image window 1 Position the pointer in the Image window where you want to add a band The pointer changes to a drawing tool K indicating that you can add a band at that position If the pointer displays a different shape you are too near another feature to add a band 2 Click to add a band Note Ifthe image is zoomed out editing the bands and edges might be more difficult See the section The Image window toolbar in Section 4 11 1 to find out how to increase the magnification of the image 3 Adiamond appears centred on the position or the nearest peak to the position that you have chosen Horizontal red lines appear above and below the diamond indicating the edges within which the volume measurements are made The Analysis window also reflects the new band Use this method to add all required bands 4 To clear all the bands click the Clear button in the Navigator 5 To delete only selected bands see the following section on Deleting bands Editing band edges in the Image window The software requires that there be an edge at either side of a band s peak in order to define the total area of the band for measurement If two bands are near to each other they might share an edge Edges are represented as horizontal lines in the Image window and can be moved into a new position To move a
91. ine windows 8 4 The Toolbox windows You can show hide any of the windows by clicking the buttons on the window selector bar The windows of the Toolbox module are described below 8 4 1 Toolbox Image window The Image window displays the BE Image Window Zoomed to Fit TETE image with which you are working a ney and is overlaid with analysis information Usually this information shows the location and name of the shapes and lines defined on the image Multi channel Images Background shapes are not visible on multi channel images when the channels are displayed in the Channel Overlay view mode Therefore you cannot Create Edit or Delete background shapes in this viewing mode Me As with all of the modules most of the interaction with the software is done within this window using the tools located in the Navigator The Image window has its own toolbar For more information on the tools refer to Chapter 4 11 1 Image window Context menu Right clicking a shape or line within the Image window accesses the context menu For information on the Cut Copy Paste Duplicate and Delete commands refer to Section 8 2 1 Edit menu For information on Properties refer to Shape Properties in Section 8 6 3 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 153 8 Toolbox 8 4 The Toolbox windows 8 4 2 Toolbox Second Image window This window facilitates the viewing of channels in multi channel im
92. inish command ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 71 5 1D 5 6 Options Description Instruction Profile scale This list allows you to select the scale used in the X axis on the profile graph to indicate position along the lane e Pixel Position The basic scale relating to the number of pixels on the image occupied by the lane e Inches and mm If your image file contains information relating to the resolution at which it was captured these options can be applied e Rf Shows the profile graph Retardation factor X axis coordinates Note The lane images are warped to line up their features with the Rf and Molecular Weight scales of the profile graph If the calibration information is not available the image and profile will not be shown e Molecular Size This scale requires that you perform Molecular Size Calibration first The X axis of the graph is given descending values of Molecular Weight against a logarithmic scale or descending values of pl in a linear scale Note Ifchanging to Molecular Weight affects your profile or images dramatically the calibration does not fit very well 72 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 1D 5 5 6 3 Tables tab in 1D The Tables tab list contains two fields Calib Norm Volume and Band Percentage Calib Norm These fields hold different data values depending on whether the Quantity Calibration or Normalisation mode is active Image Analysis
93. ion refer to Saving a marker configuration in Section 4 8 6 Using markers 4 8 6 Using markers To help you select your cropping area relative to fixed points on the scanner bed you can set alignment markers By setting the alignment marker to the corners of your sample material and the cropping rectangle to the area you want to analyse within that sample you will make a configuration that can be used across all similar samples Setting an alignment marker Activate the marker mode by clicking the button on the Image Editor toolbar then click on the image to place the alignment marker Moving a marker Move the marker by positioning the pointer over the marker and then drag the marker to the new location Note You must be in Selection mode D to move a marker By moving both the cropping rectangle and alignment marker you can make use of your previously saved configuration of marker and cropping rectangle across different scans ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 43 4 The Common Interface 4 8 Image Manipulation Clearing a marker Click Marker Clear to remove an alignment marker Saving a marker configuration To save the configuration i e the marker and the cropping area click Marker Save Save the configuration to any location the file will have an mrk extension Loading a marker A previously saved configuration of marker and cropping rectangle can be loaded across different scans To
94. ion command from the Next button s menu You can also select this command from the Analysis menu Click the Parameters tab and click a background subtraction method button Multi channel Images Each channel of a multi channel image has an independent set of objects that are used when subtracting the background of the objects You can only create edit or delete objects when the Single Channel view mode is selected You will notice that existing background objects are not visible in the Channel Overlay view mode Only the objects on the current channel are deleted when you click the Clear button in the Navigator Select each channel individually and then click Subtract to remove the background of the objects from the current channel ee 164 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA Selected method i None Local Average Local Median Histogram Peak mage Rectangle Ellipse Toolbox 8 8 7 1 Background subtraction methods The Parameters tab contains the following background subtraction methods None Use the None method to turn off background subtraction The calculated raw volume will be the sum of all pixel intensities in that area Although this method can be useful it is not recommended for good laboratory practice Local Average The local average method determines the mean of all the pixel values in the object outline and uses this value for the background Local Median The local m
95. isplaying in channel overlay view mode In overlay viewing mode any combination of channels can be viewed in the main image window 1 Click the Channel Overlay view mode button on the main toolbar 2 Onthe main toolbar click on each desired channel image button The channels appear as one image each colour representing a different channel ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 13 3 Multiple Channels 3 4 Analysing Multi channel images 14 3 4 Analysing Multi channel images When analysing multi channel images the parameters you specify are applied to all channels For some analysis modes you may need to be in Single Channel view mode to apply the parameters e g the 1D Molecular Size Calibration parameters 3 5 Multi channel Reports When generating and printing multi channel lane reports only the current channel will be included in the report Report generation cannot be performed when the channels are displayed in Channel Overlay view mode ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA The Common Interface 4 4 The Common Interface ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 4 1 Control Centre window After starting the software you see the Control Centre window This window provides access to the analysis modules 1D Array Colony Counter and Toolbox You will also see links to the IQ Tools and FluorSep programs ImageQuant TL Control Centre DER ImageQuant TL ah 1D gel analy
96. lcome to ImageQuant TL The ImageQuant TL software provides a complete software package to meet your image analysis requirements The software consists of the 1D Array Colony Counter and Toolbox modules integrated into one package with each module started from the ImageQuant TL Control Centre This software analyses 1D gels dot and slot blots microplates other basic arrays and colony images captured by the scanner The Toolbox module analyses an image using area and profile based tools The analysis programs are flexible and easy to use 12 The User Manual This user manual has been written with individual sections covering the common interface of the software and its specific modules Each module section will guide you through most of the analysis procedures so that you can understand how each module works The procedures provide a quick introduction to the analysis modules instead of a comprehensive guide to all the features of this software Multi channel Images Throughout this manual you will see text distinguished by two parallel lines as illustrated in this small section This text relates to the relevance of the tool or feature when used with a multi channel image Ne To help you pictures are included that show what you should expect to see on the screen Note You should have basic knowledge of how to use the Microsoft Windows operating system If you are unfamiliar with the Windows environment see
97. le in the software 4 3 1 File menu From the File menu you can perform the following actions Note Ifyou close the module open an image or open an existing experiment the software automatically saves the current experiment for you Open Image The Open Image command displays a dialog box that allows you to locate and open an image file The same dialog box appears If you click the Open button on the toolbar For more information refer to Section 4 14 Opening an image Invert Most images have high pixel values high intensities in the Measurements black areas of the image and low values in the white areas However in some images the spots have a low intensity and therefore low volume compared to the background The Invert Measurements command allows you to correct this by inverting all the pixel values before using them to calculate the measurements To invert a pixel value the software subtracts the value from the maximum possible pixel value in the image For example if the image has a pixel value range from 0 to 255 and the software inverts a pixel that has a value of 50 the inverted value would be 255 50 205 To invert the measurements data click File Invert Measurements and then check the data in the measurements window 16 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA The Common Interface 4 Image The image properties dialog box has three tabs File info Properties Scan info and History The i
98. load a marker configuration click Marker Load An Open dialog box displays allowing you to locate a marker file 44 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA The Common Interface 4 4 8 7 Rotating images An image can be rotated if it has been scanned the wrong way around Click either Image Rotate clockwise or Rotate anticlockwise to rotate the image 90 in the selected direction Freeform Rotating Selecting Freeform rotate places a grid over the image To change the orientation of the image take the following steps 1 Place the pointer anywhere in the Image Editor the pointer changes to 2 Drag the grid into the new position The image rotates upon releasing the mouse button 3 Repeat as necessary 4 8 8 Flipping an image Clicking either Image Flip horizontal or Flip vertical flips the image around the horizontal and vertical axis 4 8 9 Filtering the image Applying a filter to an image removes noise from the image You should not remove noise unless it is necessary 1 Clicking Image Filter displays the Filters dialog box that allows you to set the filter parameters Filters x Filter Type Hi Median Impulse Filter Options Matrix width 5 Matris height 5 Gares Am 2 Select the Filter type either Median or Impulse 3 Set the Matrix Width and Height by using the spin buttons or type the parameters in the text box 4 Click Apply to apply the filters to the image The Apply com
99. mand displays the changes and leaves the dialog box open allowing you to change the ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 45 4 The Common Interface 4 8 Image Manipulation 46 filter if desired However if you click OK the filter is applied and the dialog box closes Filters are applied to the whole image or all channels of a multi channel image 4 8 10 Changing the Contrast and Colour You can change the contrast and colour in the Image Editor For more information refer to Section 4 5 Contrast and Colour 4 8 11 Zooming an image Using the following commands on the Zoom menu can change the magnification of an image or channel e Zoom in Zoom out Zooming in increases the level of magnification and zooming out decreases the level of magnification e Zoom1to1 Reverts the image to its original size e Zoom to fit Scales the image up or down to fit the window whenever the Image Editor window is re sized ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 4 9 Navigator The Common Interface 4 The Navigator occupies the left side of the module main window It displays the tools relating to each analysis mode of the active module The features of the Navigator follow the same basic layout therefore learning to use each of the integrated modules is relatively easy The features common to all modules are discussed in the following sections Refer to the module section for the individual analysis fe
100. me the lanes to identify them by selecting the Lane names check box from the Ruler options dialog box see also Ruler Options dialog in Section 5 6 1 Image tab in 1D Renaming lanes 1 Click the lane name in the Image window ruler that you want to change An edit box displays 2 Type the new name and then click outside of the edit box or press Enter You can add more lanes to the gel image at any time You can also delete lanes if you do not require them To define and edit the lanes you should e Create the lanes automatically see Section 5 9 3 or draw the lanes manually see Section 5 9 4 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 79 5 1D 5 9 Lane Creation Optionally you can e Set tiers see Section 5 9 1 e Create an area of interest AOI see Section 5 9 2 e Move lanes in a multibox or individually see Section 5 9 5 e Bend and resize lanes in a multibox or individually see Section 5 9 5 e Delete lanes see Section 5 9 7 These options are available from the Lane Creation mode which is started either from the Lane Creation tool in the Navigator or from the Analysis menu 5 9 1 Setting tiers If the gel image has distinct sections you can split vmsememe the gel image into a number of sections called a aL zajedi tiers Each tier should contain one set of lanes To set tiers on an image I lt 1 Atthe bottom of the Navigator click the Parameters tab Select the number of ti
101. move a handle Position the pointer over the handle and drag As you move the handle the background line updates to show the affect of the new position After you release the mouse button the software recalculates the data Notice that the background cannot be set above the profile at any given point and the line changes shape where it touches the profile To remove a handle Position the pointer over the handle and then right click The pointer changes to The handle is removed and the background data is recalculated You cannot remove the two end handles of the background line 5 11 Band Detection Band Detection allows for the automatic finding of bands and manual editing of bands in the lanes of the image After you defined the lanes you are ready to determine the position of the band peaks and edges The Detect Bands mode offers you automatic methods for finding the bands and also allows you to edit the bands manually There are two main purposes of band detection the detection of peaks and the detection of edges The peak of a given band is the point in its profile where the image intensity is at its maximum value This is used to define the band s position in the lane The bands are rarely a single pixel in length therefore the extents of the band must also be determined so you can measure the band s volume These edges are found where the software locates the troughs in the lane profile at either side of the
102. mum Spot Edge Average i Negative Controls mage Rectangle None Brief descriptions of the various methods can be found later in this section 2 Provide any parameters required by the chosen method as outlined in the brief descriptions After you select the method and parameters required the software automatically calculates the spot volumes and displays the data in the Measurements window ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA Array 6 6 7 1 Providing parameters Some of the background methods available require you to select extra parameters For those methods that require parameters a list of the parameters is shown in the upper part of the Navigator Methods that do not require parameters e Spot Surface Minimum see Section 6 7 2 e Spot Edge Average see Section 6 7 3 e None see Section 6 7 6 Methods that require extra parameters e Negative Controls see Section 6 7 4 e Image Rectangle see Section 6 7 5 6 7 2 Spot Surface Minimum The Spot Surface Minimum method locates the lowest pixel intensity within the spot and then removes this intensity from the volume for each pixel You can use this method to ensure that no part of the defined spot is below the background level for each spot You should use this method for images with little noise and an even background intensity 6 7 3 Spot Edge Average The Spot Edge Average method locates the average intensity around the spot s outline and
103. mum peak 3 When you change the parameters band detection is automatically performed on all lanes using the new parameters This can be useful for instantly seeing the effect of small changes to one of the parameters The peak detection parameters are Minimum slope This parameter represents how pronounced the band must be from its Surrounding area in the lane The range for this parameter is 0 999 A high value means that the transition from the background lane intensity to the band s peak intensity must be sharp A lower value allows the gradient to be less severe In general the lower the minimum slope value the more bands are detected ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 1D 5 Noise reduction This parameter represents the degree to which small local peaks should be ignored on the profile and is designed to eliminate noise in the image Noise reduction has no effect on the profile itself only the number of peaks detected In general the higher the Noise Reduction value the fewer peaks detected Range 0 20 Percentage Maximum Peak This is a threshold parameter which discards peaks under a certain size in relation to the highest peak on the gel The higher the percentage value entered here the fewer the peaks likely to be detected in the profile The sizes of the peaks are calculated after background subtraction The range for this parameter is O 100 5 11 2 Edge Detection Parameters After you
104. n Display options Bands This option allows you to toggle the bands on or off It can only be applied after you have completed all the analysis tools Annotations This option allows you to show the user defined annotations created while in Annotation mode 68 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 1D 5 Description Instruction Ruler options Click the Ruler options button Ruler options to display the Ruler Options dialog box Ruler Options x Ruler information The ruler can be used to display various types of i 54 information PF Lane names Display names vertically MW Lane numbers PF Molecular size Tier 1 Select Tier Font style A The font used on the ruler can also be changed Ruler font Avia Bald Spt Change From the Ruler information display options you will be able to select the following ruler options see below Ruler options dialog Lane Names Select the check box if you want to identify the lane by a name above the image Clear the check box if you do not want to identify the lanes Clicking the name on the image and typing the new name in the text box edits the name Display Names Select the check box to display the lane names vertically Vertically Clear the check box to display the lane names horizontally Lane Numbers Select the check box to display the lane numbers above the image Clear the check box if you do not want to display the lane num
105. n 8 6 3 To group objects press the Ctrl key and click each object in the Image window that you want to include in a group When selected each object displays handles small squares With all desired objects selected click Group Selection from the Object menu A dotted rectangle appears around the grouped objects Use this command to change a group of objects into individual objects 1 Position the pointer over an object the pointer changes 2 Ifyou click an object that is part of a group a dotted rectangle appears identifying a group 3 Click Ungroup from the Object menu Use this command to change the object s format in the following ways Left Right Top Bottom Top Bottom Centre and Left Right Centre You can space a group of three or more objects equidistantly using either the Space Across or Space Down commands You must select at least 3 objects for this feature to work Objects cannot overlap If the objects overlap a message appears and the software cancels the action The formats are e Space Across All selected objects are spaced out evenly between the leftmost and rightmost objects e Space Down All selected objects are spaced out evenly between the top and bottom objects ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA Toolbox 8 8 3 Window Selector bar The window selector bar located at the bottom of the Navigator contains buttons for activating the Image Second Image Zoom Area and L
106. n AA 49 4 The Common Interface 4 10 The Analysis tools 4 10 The Analysis tools You use the various analysis tools displayed in the Navigator to analyse your images The parameters associated with each analysis tool of the modules are displayed in the parameters tab For more information refer to the relevant module sections 4 10 1 Refining your analysis results After completing your analysis using the analysis tools clicking the Next button for the final time displays a full set of analysis modes The Next button changes to the Restart button a In the 1D module you will see extra features displayed in the Navigator Help Parameters pane as in the example below Show Current Lane only Show Additional Lanes A Lane Selection For more information refer to Section 5 15 Experiment Overview section 1 Click an analysis mode button in the Navigator or select a mode from the Restart list Spot Definition Background Subtraction Normalisation Presence Flagging st Finish 2 Set the new parameters for the selected analysis mode 3 Click Next or select the mode you want to refine from the list You can select the various analysis modes in any order 50 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA The Common Interface 4 4 11 The Program Windows The main window contains a number of smaller windows Each of these windows contains a different type of information The windows can be activated using t
107. n item s colour click the coloured box next to it Select a new colour from the colour dialog box and click OK ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA Array 6 6 5 2 Array s Tables tab Using the tables tab you define which data fields you want to display in the different tables To select a data field click the check box adjacent to the field name To change their order highlight a field then click the up or down arrows For more information on the available data fields and their definitions refer to Data Fields in Chapter 4 6 2 Tables tab You can only select one data field for the Current Grid table Image Tables Reporting Table fields eed Each of the tables in the Measurements Window can show y different types of data These can be selected below Select fields for table showing Current Grid CIS Label Mi olume Volume Background Background CONormalsed olume Presence Absence CSpot Quality 6 5 3 Array s Reporting tab The Reporting tab allows you to define the printable image area and print scale It also allows you to set the preferences for the page layout for tables Image Tables Reporting Image area When printing or copying an image you can choose how much of the image you want Visible area of the image Whole of the image Print scale Images can be printed using one of three scaling methods Fittothe page Scaled fico i Act
108. nchor arrow or text box 1 Position the pointer over the anchor arrow or text box you want to move The pointer changes to a crosshair for the anchor arrow and the text box becomes outlined 2 Drag the arrow or text box to the desired location Selecting annotations To select a single annotation you can e Click on either the arrow the line between the arrow and the text box or the text box e Press the TAB key to move between annotations Select all To select all the annotations you have created right click anywhere in the image away from any annotation The context menu appears allowing you to select all the annotations Deselect all To deselect all the annotations right click anywhere in the image away from any annotation The context menu appears allowing you to deselect all the selected annotations Arbitrary To make an arbitrary selection of annotations left click on selection the first annotation and then hold down the CTRL key on your keyboard You can now click on each annotation you want to include in your selection Right click in the image for your next action To arbitrarily deselect an annotation hold down the CTRL key on the keyboard and then left click on the annotation Editing the text of an annotation After adding annotations you can edit the text in the annotation by right clicking the outlined text box and selecting Edit text from the context menu or left clicking the text box While editing
109. ndow and you see the image at an increased magnification To resize the scroll box position the pointer on an edge of the scroll box the pointer changes to or i Drag the pointer to the new position When the scroll box indicates a display of the total range of the scroll bar the scroll box becomes transparent When it indicates that only a portion of the range is visible the scroll box becomes opaque ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA The Common Interface 4 4 12 Window Selector bar The Window Selector bar below the Navigator allows you to display the smaller windows The selection state up or down of each button indicates whether that window is currently displayed Clicking a button displays or closes the window 4 15 Status Bar The status bar is the thin bar along the bottom of the main window It displays information about the current state of the program e g Ready as well as descriptive messages for a selected command or toolbar button e g Co ordinates Pixels nnn Pixel Value nnn 4 14 Opening an image You can open an image by clicking any of the analysis module buttons or links in the Control Centre Alternatively you can open an image by clicking File Open image or by clicking the Open button on the main toolbar Open 21 x Look in E Images Ari F 1d_Basic tif Colony_Petti tif E 1d_MWwPLTIF E Colony_Spots tif Array_Microtitre tif File name I Files
110. near another feature to add a band If the profile graph area is small and you are viewing the whole of the profile graph it might be harder to edit bands and edges To give a better view zoom into a desired area Refer to The Image window toolbar in Section 4 11 1 for more information 2 Click to add a band An arrow appears over the profile directed at the chosen location Dotted vertical lines appear to the left and right of this location indicating the edges within which volume measurements are made The Image window also reflects the new band With this method you can add all the required bands If you want to clear all the bands click the Clear button in the Navigator To delete some of the bands see the section below on deleting bands Editing band edges in the Analysis window Edges are represented as dotted vertical lines in the Analysis window and can be moved 1 Position the pointer over the edge you want to move The pointer changes to 2 Drag the edge left or right along the lane s length to the desired location You cannot move the edge past a band or off the lane 3 Release the mouse button when the edge is in the desired position The software updates the Image window and Measurements tables accounting for the new band size ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 1D 5 If you move a shared edge a second edge is created This edge can be placed between the left band and the original ed
111. nformation in these tabs is read only e The File info tab displays information about the image for example the File Name Size Image Width and Image Height The Scan info tab displays information relating to the scanning of the image for example the Scanner make model date and time of scan and the resolution It also shows any comments from the scanning The History tab displays the name of the image and a scrollable list of any editing made to the image for example Rotate Clockwise 90 Print The Print dialog box allows you to select a printer print range and number of copies To print the image and or the measurements data you need to activate the window Print Setup The Print Setup dialog box allows you to select a printer and its properties You can select a paper size source and the page orientation Print Preview The Print Preview window displays the image or measurements data from the selected window so you can see how it will be printed Clicking the Preview button on the main toolbar also displays the Print Preview window Printing The Printing Options command displays the Options Options Reporting tab that allows you to amend the print range and scale For more information refer to Section 4 6 3 Reporting tab The type of dialog box that will be displayed depends on whether a window with an image or with tabular data has been selected for printing Alternatively clicking the Options button in the print p
112. notations 6 3 Window Selector bar AAA The window selector bar located at the bottom of the Navigator contains the buttons for activating the Image see Section 6 4 1 Second channel see Chapter 4 11 3 Zoom see Section 6 4 2 and Measurements see Section 6 4 3 windows used in the Array module ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 117 6 Array 6 4 The Array windows 118 6 4 The Array windows You can show or hide any of the windows by clicking the corresponding button on the window selector bar 6 4 1 Array Image window The Image window displays the image BA Image Window Array_Blot tif Bilal Ea upon which you are working and is overlaid with analysis information Usually this information shows the location of the spots defined in the image As with all of the modules most of your interaction with the software will be done within this window using the tools located in the Navigator Multi channel Images When analysing multi channel images spots will be visible in both the Single channel and Channel Overlay viewing modes i The Image window has its own toolbar For more information on the tools refer to Chapter 4 11 1 Image window 6 4 2 Array Zoom window The Zoom window displays the whole image overlaid with a rectangle representing the area ds aes r of the image that is currently displayed in the Image window Drag the rectangle to a new position to display
113. ns on the side of the text box When you release the button the data updates automatically in the measurements table The pixels in this area that are not part of any colony are then examined and the most frequently occurring pixel intensity is deemed to be the background value for that colony In 12 and 16 bit images the number of possible different pixel intensities means that using the most frequent pixel value is unlikely to produce good results When this method is used on such an image each pixel intensity is assigned to one or more overlapping groups of intensities The background value is then calculated as the average of the most heavily occupied group 7 8 3 None This method clears any background subtraction calculations It has the same effect as clicking the Clear button in the Navigator 7 8 4 Clearing background values If you have used any background subtraction method automatic or manual clicking the Clear button in the Navigator clears the background values from the Measurements table ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 147 7 Colony Counter 7 8 Background Subtraction in Colony Counter 148 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA Toolbox 8 8 Toolbox 8 1 Introducing Toolbox Toolbox allows you to perform analysis on a wide variety of images The flexible nature of the software means you are not restricted to a single type of analysis when you use this module To help you along
114. nt spots or bands because the human eye is often more sensitive to colour than to shades of grey To change the colour scheme select a different scheme from the list Colour Wells This group of three controls displays the three colours that define the current colour scheme these descriptions assume that the Invert option is off otherwise they should be reversed The first box displays the colour used to represent pixels of high intensity the second represents medium intensity and the third represents low intensity The palette for the image will be calculated by changing smoothly between these three colours Reverse colours This feature is only available in the Colony Counter analysis module The check box indicates whether the current colour scheme should be inverted or not click it to toggle the option on or off Inverting an image causes it to be displayed like a photographic negative For example using the default Grey Scale colour scheme white becomes black ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA The Common Interface 4 4 6 Options The Options dialog box displays various tabs each tab allows you to select settings relevant to the individual analysis modules To display the Options dialog box click View Options Alternatively click the Options button on the toolbar The Image tab for the individual analysis modules will differ slightly and the 1D module also has an extra tab For more information please
115. ntry in the area window can K select that object and centre it in the Image window in the Area window M Synchronise object selection with table cell selection V Automatically centre image on selection Cancel 156 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA Toolbox 8 8 5 3 Line window tab This tab allows you to choose which line objects have their profiles displayed in the Line window Click either Currently selected line objects or All line objects 8 5 4 Reporting tab in Toolbox The options set in this tab are common to all of the modules For more information refer to Chapter 4 6 3 Reporting tab ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 157 8 Toolbox 8 6 Shape Definition 158 8 6 Shape Definition In this mode the Navigator displays the objects in two categories areas and lines While creating moving or resizing any of the objects you can press the Esc key to cancel the action Multi channel Images Each channel of a multi channel image has an independent set of shapes Shapes can only be created edited or deleted in Single Channel view mode these functions are not available in Channel Overlay View mode When you delete all the objects using the Clear button in the Navigator only the objects on the current channel are deleted Ne 8 6 1 Areas The measurements for area shapes are displayed in the Area window The Areas category has six specific shapes
116. olour that is used to draw the arrow line and outline of the annotation text box The default outline colour is green Opaque Select the check box if you want the text of the annotation Background drawn over a coloured background or clear the check box if you want the text drawn directly onto the image ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 25 4 The Common Interface 4 5 Contrast and Colour 26 4 5 Contrast and Colour Making changes to the Contrast or Colour only affects the current analysis module The Contrast and Colour controls allow you to alter how the selected channels look on screen 4 5 1 Contrast This dialog box is used to change the contrast and brightness of the image Multi channel Images When you are viewing multiple channels you can switch to one of the other selected channels from the drop down list The contrast is edited on a per channel basis This feature is not available in the Colony Counter module Y Channel1 P Invert display Preview Edit sample area Image Histogram High 523318 Defaults o Counts 6502 Manual Low Med High Invert display This check box indicates whether the current colour scheme should be inverted or not click it to toggle the option on or off Inverting an image causes it to display like a photographic negative For example using the default Grey Scale colour scheme white becomes black and vice vers
117. omparisons tables in the Measurements window ensure that you have the Molecular Size field selected in the Options dialog box Click View on the menu bar or click the Options button from the Toolbar Alternatively you can set the Analysis window display options by selecting the Show Molecular Size check box in the Analysis tab to show the Molecular Size annotations for the bands Note The annotations are displayed below the Lane image in the Analysis window If you cannot see the annotations adjust the size of the lower display box by dragging the edge ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 1D 5 The graph showing the relationship of molecular weight or pl to the position for the current lane appears in the Graph window Multi channel Images When performing Molecular Size Calibration on multi channel images only one channel can contain MW standards The standards that you set in the chosen channel are used to generate MW values across all the other channels You can only set standards on a channel when you use the Single channel viewing mode To apply standards to a different channel you must Ensure that you are in single channel viewing mode Remove the standards from the original channel Y 5 12 1 Applying Values To Standard Lanes To perform Molecular Size Calibration you must first assign the known values to the bands of the standard lane 1 Inthe Parameters tab select the mappings list from
118. on refer to Section 8 6 Shape Definition Background To calculate the background subtraction drag a rectangle Subtraction over the image in the Image window The software calculates the average intensity inside the rectangle and subtracts the value from the measurements displayed in the Area and Line windows For more information refer to Section 8 7 Background Subtraction in Toolbox Experiment The remaining tools on the Analysis menu are common to all Overview and the modules The Experiment Overview and Annotate Image Annotate commands are discussed in the common interface section Image Refer to Refining your analysis results in Chapter 4 10 The Analysis tools and Chapter 4 4 Annotations ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 151 8 Toolbox 8 2 Main Menu Bar Object Show Hide Group Selection Nora Alignment 152 8 2 3 Object menu Group Selection Alignment Click Object Show Hide to display the Show Hide objects dialog box From the list you can select any object and apply the show or hide command This feature affects the data shown in the Area window Note Ifyou hide an object the software does not deleted the object If you have multiple area or line objects drawn in the Image window you can group them Grouped object properties can be changed in the same way as single objects For more information on changing properties refer to Shape Properties in Sectio
119. ony Counter module The procedures provided in this section are basic examples of how to analyse colonies You can fine tune your analysis using the various editing tools The Colony Counter module is supplied with two image data files of previously saved data stored in the TIFF file format The image used in this section to describe the various features can be restored if you want to follow the procedural steps To restore the image click Restore Default Image from the Help menu Note The Colony Counter module does not have the capability of opening multi channel images 7 2 Main Menu Bar The main menu bar of Colony Counter is the standard Analysis menu bar for all the modules with the exception of the v ee see F tin Analysis menu Background Subtraction Experiment Overview These tools are discussed in the following sections ee nDe Mage e Detection see Section 7 6 e Editing detected colonies see Section 7 7 e Background Subtraction see Section 7 8 For more information on Experiment Overview and Annotate Image refer to Refining your analysis results in Chapter 4 10 The Analysis tools and Chapter 4 4 Annotations ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 135 7 Colony Counter 7 3 Window Selector bar APE 136 7 3 Window Selector bar The window selector bar located at the bottom of the Navigator contains three buttons for activating the Image Zoom and Measurements windows used in
120. or Ellipse to a new location 166 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA Glossary of Terms 9 9 Glossary of Terms Background subtraction Background subtraction is the name given to the removal of the background intensity that runs throughout your images Check box A square box that is selected or cleared to turn on or off an option More than one check box can be selected Context menu A context menu is a small popup menu allowing you to select commands pertaining to the current feature Current window This is the window that has the highlighted title bar and is currently active Data file The storage of analytical information about the gel on the computer hard disk or network drive Dialog box A window containing buttons and controls allowing you to set options or perform operations Handles A small rectangle over a feature on the image which allows you to interact with that feature usually to re size it Image Rectangle The method of background subtraction which uses the average intensity in an area on the image as the background intensity Mode The current set of interactions possible to perform analysis in the program Modules The modules consist of 1D Array Colony Counter and Toolbox which are the tools used for analysing 1D gels dot and slot blots microplates and colony images captured by a scanner Molecular Size Calibration A mode which is used to relate the position along a lane to the
121. or you can choose one standard as the best example After the horizontal contours have been determined the software uses the selected curve fitting algorithm to determine the relationship of molecular size to a position along the lane for all the points in all the lanes From this you can determine the molecular size of any given band in any of the lanes In order to perform molecular size calibration you must detect the bands in at least the standard lanes although band detection should be complete by this stage You can edit the bands of the lanes after calibration without losing the calibration information If you edit the bands of a standard lane the lane ceases to be a standard lane until you re assign the known values to Its bands In order to assign the Known values to the bands of the standard lane the software uses mappings lists or standards Each mapping list contains a set of values for the bands that separate in a standard lane and the unit of measurement of those values There are several mapping lists already defined in the software but you can define and use your own Molecular size calibration is accessed from the Molecular Size Calibration button Al in the Navigator or by clicking Molecular Size Calculation from the Analysis menu After you start the Molecular Size mode new controls appear in the Parameters tab of the Navigator To see the results of your molecular size assignment on the bands in the Selected and C
122. ork independently of the other channels in a multi channel experiment Because calibration is performed on a per channel basis you must select the individual channels and then click the Calibrate button in the Navigator This rule also applies when you want to clear the quantity calibration standards from the channels by clicking the Clear button Y The table in the Parameters tab of the Navigator displays a list of the bands you have selected to create the calibration curve together with their assigned calibrated volumes 1 Ensure that you have the desired table fields selected in order to display your Quantity Calibration results in the Measurements window 2 Select the required data fields from the Tables tab in the Options dialog box by selecting the check boxes on the left side 3 Toselect a band in the Image window click on the small diamond on the band The pointer changes to when you are over the band An in place edit box appears 4 Type the band volume in this box and press Enter to accept it If you have selected the band by mistake press the Esc key to stop editing Click OK to the message displayed ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 1D 5 5 The band in the Image window displays the value you have entered The software also adds the band with the volume to the table in the Parameters tab of the Navigator 6 Repeat the steps above to select more bands Every time a band is added the software
123. ou make with the pointer in the Image window 160 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA Toolbox 8 8 6 3 Object Editing After you have created an object on your image you can resize and move the object or change the properties For more information refer to the following sections Resizing and moving objects Resizing an object 1 Position the pointer over the edge of the object you want to resize Depending upon what shape of object you are editing the pointer changes to either or when you are over a movable handle 2 Click and drag the handle to a new position and release the mouse button At any time while dragging you can press the Esc key to cancel the action and restore the object back to its original location Handles of freehand lines or in multiple selections cannot be moved Moving an object or group of objects 1 Click the boundary anywhere other than a movable handle of an individual object or object group The pointer h changes to T 2 Drag the object or group to the new location on the image Moving multiple objects 1 Press the Ctrl key and click each object 2 Drag the selection of objects to the new location on the image ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 161 8 Toolbox 8 6 Shape Definition 162 Selector The Selector feature is an editing sub mode To activate this feature click the Selector button in the Navigator The Selector featur
124. ound The background range is 0 14999 Change the value by clicking the up or down spin buttons to the right of the text box When you release the spin button detection takes place automatically Alternatively you can change the parameter by typing the value in the text box Click the Detect button to redetect the colonies e Automatic splitting Automatic splitting is the process when the software attempts to split partially overlapping colonies The automatic splitting range is 0 9 142 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA Colony Counter 7 If the parameter is set to 0 the software does not attempt to split colonies increase the value to activate this feature When you have finished editing the colonies click the Next button in the Navigator 7 7 Editing Detected Colonies After detecting the colonies three basic tools allow you to edit the colonies The tools are Draw or Erase Features Delete Features and Split Features There are additional commands to Re number and Clear detected colonies Click the various buttons in the Navigator to activate the tools This section describes the basic steps of editing colonies Your actual editing depends upon the parameters that you initially set in the Navigator for detecting the colonies When you draw undetected colonies in the Image window the coordinates are displayed on the status bar at the bottom of the screen After you have edited a colony the softwar
125. owing enter a different title in the text box or click the Default report title button to use the default title To add a Title to your report 1 Select the Show the following report title check box 2 Type a title in the text box The title will be placed in the top left corner of the report Clicking the Default button clears the text box The default is usually set to the name of the registered user of the software Show analysis Select this check box if you want the Background and Band parameters Detection parameters to appear at the top of the Lane reports These are the analysis parameters used when creating the band data 76 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 1D 5 5 7 The current experiment lane and channel Throughout this section you will see references to current experiment current lane and current channel These are described below Current Current experiment refers to the experiment that is presently experiment loaded in the active module You can only work one experiment at a time Current lane Many of the windows in the software show you data relating to the current lane Within the Image window the current lane is indicated by a coloured outline usually green All the windows are updated automatically when you change the current lane and show the data relating to the new selection You change the current lane selection by clicking another lane number in the ruler of the Image window
126. pe object Note The name displayed in the table can be changed using in place editing or the Properties dialog box Normalised Volume The Normalised Volume of the spots Array Colony Toolbox Counter Peak Background The maximum value of the Profile of the Band with the Background value added Peak Height The maximum value of the Profile of the Band not including the Background Percent The percentage of total volume for all area objects represented by a given object Position The distance in pixels of the band s peak from the start of the lane Presence Absence The Current Grid of Array displays a 1 for spots that contain a sufficient quantity of material to be considered present and 0 for spots not considered as present The threshold volume can be set in the Presence Flagging dialog box 34 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA The Common Interface 4 Data Field name Description Colony Toolbox Counter Rf Rf Retardation Factor is a measurement of position along the lane relative to its length By default the first position in each lane has an Rf of O and the last has an Rf of 1 There is a linear increase in Rf from start to finish Std Dev The standard deviation of the pixel intensities within a given area Spot Label Use in reporting and identification of spots in the image The label for a spot can be edited in the Spot Properties dialog box and in the table when you select t
127. r Manual 28 9175 41 Edition AA 125 6 Array 6 6 Spot Definition 126 6 6 5 Adjusting a grid to allow for a skewed image You can uniformly stretch the positions of spots in a grid between the grid s four corners by clicking the Create and Stretch Grid mode This provides a way to quickly adjust the grid to cope with images in which the spots are aligned in a skewed rectangle Repositioning the spots by stretching the grid 1 Click the Create and stretch grids button 2 Drag one of the grid s square corner handles to a new location The spot positions are stretched uniformly between the four corner handles of the grid 6 6 6 Resizing spots Spots can be resized in two ways by stretching or by defining the spot radius value To change the radius by stretching a spot 1 Click the Move and Resize button 2 Select the spots whose radius you want to change 3 Position the pointer over the spot edge at the top bottom left or right edge The pointer changes to either or 4 Drag the edge to the desired size for all the selected spots While the radius of a spot is changing its value measured in pixels is displayed in the status bar To cancel resizing the spots right click or press the Esc key while dragging ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA Array 6 6 6 7 Editing spot properties You can edit the properties of the selected spots using the Spot Properties dialog Identification box Spot ID Gr
128. raph i e the calibration You can restore the default contrast at any time by clicking the Defaults button ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 27 4 The Common Interface 4 5 Contrast and Colour 28 Low High edit boxes The Low and High edit boxes are synchronised with the two handles below the image histogram These edit boxes allow you to enter values to adjust the contrast of your image This enhances the contrast display so that for narrow contrast ranges a sufficient number of grey levels are used giving a higher quality of image display You can restore the default contrast at any time by clicking the Defaults button Brightness The two sliders allow you to adjust the brightness and contrast of the image by moving them between Low Medium and High Low Med High Drag the slider to change the brightness High paler Low darker Contrast response list Below the Defaults button there is a drop down list Select the shape of the contrast response curve to help you visualise the features of your image e Manual a straight line e Hi contrast a curve calculated from the image to maximise the contrast e Curve and Sigmoidal standard shapes of response curve adjustable via the Contrast slider Sigmaidal Oo Low Mid High The Contrast slider affects the shape of the curve that extends between the contrast limits Drag the slider to change the contrast High more effect
129. recalculates the curve and updates the Graph window 7 To change a value of a band click the diamond the in place editing mode highlights the text and allows you to enter a new volume 8 Press Enter to accept or Esc to reject the new volume Any changes you make are reflected in the tables of the Measurements window the Quantity Cal curve in the Graph window and to the table in the parameter tab i 9 Click the Calibrate button _Salbrete at the top of the Navigator to calibrate all the bands with unknown real world volume The software updates the data displayed in the tables of the Measurements window 5 13 2 Removing bands from the calibration curve 1 Position the pointer over a band you want to remove from the calibration curve i The pointer changes to when you are over the band 2 Right click to remove the band The software updates the quantity calibration curve in the graph window and the measurements tables 5 13 3 Clear all calibrated values X Click the Clear button in the Navigator _ Sear ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 107 5 1D 5 13 Quantity Calibration 5 13 4 Selecting the curve type and calibration unit You can select the curve type and calibration unit in the Parameters tab of the Navigator Curve Type Linear M Force through Origin Calibration Unit microgram 1 Click the curve type from the Curve Type list 2 If you want the curve to pass through the o
130. rectangle is initially located at the top left of the image and is drawn in the Image window This method can be useful if your image contains a lot of noise and tightly packed spots However the Spot Edge Average method might provide better results To provide the background rectangle 1 Position the pointer at the top left corner of the rectangular background area 2 Drag the pointer to the bottom right of the rectangular background area You see the rectangle drawn as you move the pointer ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA Array 6 6 7 6 None The None method allows you to turn off background subtraction altogether The raw volume calculated for each spot will be the sum of all the pixel intensities in that spot Although this method can be useful at times it is not recommended for good laboratory practice 6 8 Normalisation Multi channel Images Normalisation is applied across all channels of a multi channel image and when using either Single channel and Channel Overlay viewing mode Y To normalise spot volumes to a selection of spots take the following steps 1 Select the spots that will be used to normalise the image 2 Type the normalised volume in the Parameters tab The range is from X 0 0001 to Y 1000000 The normalised volume ts 50 nanogram When normalising to group of bands normalise to their average volume 3 Select the normalised volume unit e g nanogr
131. refer to the individual analysis module section 4 6 1 Image tab The Image tab allows you to select the various settings for the image window in the current analysis module These settings vary between the analysis modules For more information refer to the Image tab of the relevant module 4 6 2 Tables tab Within each analysis module you can select the various data fields that will be displayed in the Measurements or Area window You can also change the order of these fields by use of the arrows To select or deselect a field for display Left click the box to the left of the name in the list of fields To change the order of the displayed fields 1 Select the field to move by highlighting the name in the list of fields 2 Click on the Move Up or Move Down buttons until the field is in the desired position in the list In the Array module each table in the Measurements window can display different sets of data Only a single field can be selected for the Current Grid table Therefore the Move Up and Move Down buttons are not enabled for the Current Grid table The selected field is displayed on the Measurements table title bar ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 31 4 The Common Interface 4 6 Options Data Fields This section discusses data field availability for each module You will find a brief description of each field in the table below Not all data fields are available within the various tables displ
132. report title MyReportTitle Default Show analysis parameters Cancel You can select a report logo and title you can also select whether to show the analysis parameters For full information on the types of information you can display on your reports refer to Section 5 6 5 Reporting tab in 1D 3 You can enhance your report by adding additional notes Refer to Section 5 16 1 Adding Lane Notes for more information 4 With all report options set click Create Lane report from the Analysis menu Your report appears in the Report window which opens automatically upon generation of the report If the window does not appear click the Report window button G below the Navigator 5 To print the report click File Print and click OK in the print dialog box Note You must have the report window active to be able to print the current report ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 113 5 1D 5 16 Creating a Lane Report 5 16 1 Adding Lane Notes Clicking Edit Lane Notes displays the Lane Notes dialog box Edit the notes for RE Lane 1 Notes When you have completed your analysis you can enter additional notes here before creating your Lane Report from the option on the Analysis menu Cancel ull From this dialog box you can enter notes for any detected lane These notes are displayed on the report under the Additional Notes heading Adding Additional Notes to a report To add additional notes
133. res you to select a band or bands in the gel You will also choose a normalisation value and unit which is applied to the bands before recalculation according to the method chosen 1 Ensure that you have the desired table fields selected to display your Normalisation results in the Measurements window Select the required data fields from the Tables tab of the Options dialog box by clicking the check boxes on the left side To select a band in the Image window click the small diamond on the band Note The pointer changes to when you are over a selected band Repeat the above step as required Type the Normalised Volume parameter in the left box of the dialog box in the Parameters tab The allowed range is 0 0001 to 1000000 Select the unit of measurement from the list The ten units you can use to perform normalisation are milligram microgram nanogram picogram femtogram attogram nanomole picomole femtomole and attomole If normalising a group of bands select either the group average or collective option by clicking the button in the Parameter tab The normalised volume is When normalising to a group of spots normalise to their average volume their collective volume When you have finished setting the Normalising parameters click the Normalise button omaise gt the top of the Navigator and then check the data displayed in the Measurements table ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 1D
134. review window displays the Options Reporting tab Exit Click Exit to close the active analysis module and return to the Control Centre window ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 17 4 The Common Interface 4 3 Main menu bar 18 4 3 2 Edit menu The Edit menu contains commands that are common to all modules Some modules have additional menu items which are described in the Edit Menu section for that module The following table discuss the common commands Export to Click Export to Clipboard to copy the data or image Clipboard displayed in the active window to the clipboard so that the data or image can be pasted into other applications For example the measurements window data can be pasted into a spreadsheet Alternatively clicking the Export button on the toolbar copies the data or image Export to File Clicking Export to File displays a dialog box that allows you to enter a folder and filename e If you are exporting an image the default filename is Export bmp e If you are exporting measurements data the default filename is Export txt The default folder is the mageQuant TL installation folder If you do not want to use the defaults select the folder in which you want to store the file and type in a name and then press Save Export to Excel Export to Excel is only available when the Image or Measurements window is active and if Microsoft Excel is installed on your computer The data in
135. rigin click the Force through Origin check box 3 Click the units for the calibrated values from the Calibration Unit list There are ten different measurement units to choose from milligram microgram nanogram picogram femtogram attogram nanomole picomole femtomole and attomole You can change the settings of the curve at any time and the software recalculates the calibration values 108 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 1D 5 5 14 Normalisation Normalisation can be used to normalise the volumes in a gel image that sets the normalised volume of a band or a group of bands to a specific value and then recalculates all the other volumes relative to that value Normalisation can be useful when comparing the volumes across lanes or gels where the loading might be different When you activate the Normalisation mode new controls appear in the Parameters tab of the Navigator The results of normalisation can be seen in the tables of the Measurements window Note Ensure that you have the Calib Norm Volume and Band Percentage Calib Norm table fields selected in the Options dialog box The tables will then show the Normalised volume and the Band Norm values respectively All the bands used for normalisation are shown in the Image window with yellow band diamonds those bands that are not included have blue diamonds These are the default colours The default colours can be changed in the Image tab of the
136. ription Instruction Allows you to move the image around within the Image window when the image is zoomed 1 Click the Panning button CI 2 Position the pointer over the image it changes to a small hand 3 Drag to change the view 4 11 2 Measurements Area window The Measurements Area window displays the analysis data results The types of data fields displayed depends upon the analysis module Preferred data fields for each analysis module can be selected cleared using the Options Tables tab for each module Refer to Data fields in Section 4 6 2 Tables tab for more information Multi channel Images In the Measurements window analysis data for multiple channels is displayed on a per channel basis Measurements Window Lane Measurements Lane 6 85606 41 6 01 4648 07 so 0 33 83719 63 41 l 5 88 55393 34 23 3 89 53708 32 35 3 77 49268 65 44 i 3 46 67614 97 4 i 4 75 186135 34 35 13 08 365684 25 39 25 69 4552 32 45 0 32 2849 91 79 28 61 521 58 5 24 1545 40 i 15 52 767 63 I 7 71 21943 49 82 15 08 9999 03 28 6 87 14551 12 A 10 00 30567 22 76 21 01 17047 89 HA 11 72 20397 32 36 14 02 1296 09 96 0 89 Dom Un BR CN o 1 2 3 4 1 2 3 4 5 6 7 Fig 4 1 Example of 1D multi channel data display ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 53 4 The Common Interface 4 11 The Program Windows 54 4 11 3 Second Image window Af
137. rs for Area of interest Circular Rectangular Parameters Sensitivity Noize factor pooo E Operator size Background Automatic splitting 7 e Area of interest Click either the Circular or Rectangular button Detection takes place automatically e Initialising sensitivity After you enter a numeric value or move the Initialise Sensitivity slider in the upper Navigator the software provides an initial value for the sensitivity based on the selected area of interest The sensitivity range is 1 10000 e Operator size This is the width of the detection operator and is proportional to the size of the spots you are trying to detect The operator size range is an odd number between 5 699 e Noise factor This represents the width of the edge and centre filters of the detection operator The higher this value the greater the compensation for noise in the image and hence the greater the accuracy However increasing this will also slow detection considerably as you are greatly increasing the amount of processing required per pixel The noise factor range is an odd number with the minimum value of 1 The maximum value depends on the selected operator size It is equal to the odd number that is nearest to half the current operator size e Background This is a bias value added to all pixel values before any calculations are performed and therefore allowing detection of images that have a very low intensity backgr
138. s relevant to the active analysis module For more information refer Section 4 6 Options 4 3 5 Window menu The Window menu contains two commands Description Arrange The Arrange windows command allows you to open and windows move the windows into a pre defined layout Close all The Close all Windows command allows you to close all Windows open windows but does not close the experiment or the software The Window menu also displays the list of the open windows in the module A tick mark denotes the active window ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 19 4 The Common Interface 4 3 Main menu bar 4 3 6 Help menu Help is provided both as online Help and online Help request links The commands available from this menu are discussed in the following table Contents Displays the online Help Alternatively you can press F1 to access the Help topics How to use Displays the Help topic that explains how to use the online Help Help Restore Restores the default image relevant to each analysis module default Image Activate If you have not registered the software you can use this software command to begin the registration process Technical This command allows you to select from the following Support e Request Technical Support e Request a New Feature e Report a Bug Each of these commands displays a form asking you to enter information The software for these forms also detects the system settings
139. sis R 7 Analyze a 1D electrophoresis gel image nalysis Toolbox Analyze a dot slot blot microtiter plate or macroarray Colony Counting Count colonies or detect 2D electrophoresis spots Array analysis Analyze an image using area and profile based tools Online Help Look up queries in the comprehensive reference quide Also contained in this installation Fluor ep l Tools Click on either the hyperlink or the button of the analysis module to start your analysis The Open Image dialog box appears Select an individual image or a multi channel ds file and then click Open the analysis module starts Clicking on their links can also activate the IQTools and FluorSep programs The Help hyperlink or button provides you with direct access to the online Help facility for the analysis modules The following sections describe the menus buttons and windows that are common to all the analysis modules For more information on each analysis module refer to the relevant section 42 The main window After vou select an image and analysis module from the Open dialog box the main window appears for the selected analysis module The main window contains a main menu bar toolbar navigator and additional windows 15 4 The Common Interface 4 3 Main menu bar 43 Main menu bar File Edit View Analysis Window Help The Main menu bar located at the top of the main window provides the majority of commands and options availab
140. sis menu You also need to re generate the report if vou change the reporting options For more information on what data a report contains and how to generate a lane report refer to Section 5 16 Creating a Lane Report 5 5 6 1D Second Image window The second image window facilitates the viewing of channels in multi channel images This window has its own toolbar For more information refer to Chapter 4 11 3 Second Image window ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 67 5 1D 5 6 Options 5 6 Options When you click the Options button or View Options the 1D Display options dialog box appears The Reporting tab is common to all modules but the other tabs have specific parameters relating to the individual modules The specific parameters for the 1D module are discussed below 5 6 1 Image tab in 1D The parameters shown in the Image tab relate to the display in the Image window By selecting the check boxes you can change the display for the various labels in the image window Image Analysis Tables Lane Selection Reporting Display options FF Different types of information can be shown or hidden in the Image window M Bands Ruler options M Annotations Colours The colours used by certain items in the program can be set by clicking on the colour box in the list Current Lane Multiple LaneBox E Normal Lane E Profile Lane 1 F Leu La 1 A _ Command Description Instructio
141. software modules Select a single image or for multi channel images select a ds file from the list in the Open dialog box 12 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA Multiple Channels 3 3 Multiple Channels 3 1 Overview ImageQuant TL allows you to display and analyse multi channel images within the analysis modules the exception being the Colony Counter module A multi channel image contains two or more channels that can be displayed in different viewing modes 3 2 Processing a Multi channel image If the fluorochromes you used in the sample creates spectral crosstalk you should pre process the image using the FluorSep program before analysing the image After removing the spectral crosstalk from the image the FluorSep program creates one image called a channel for each fluorochrome used in the sample If you used fluorochromes that do not produce spectral crosstalk you can view the images in ImageQuant TL without running the FluorSep program For more information on running the FluorSep program refer to its specific user guide 3 3 Displaying Multi channel images Upon opening a multi channel image its first channel will appear in the Image window in Single Channel view mode The remaining channel images can be viewed individually in the Second Image View window Displaying in single channel view mode In single viewing mode any one of the channels can be selected and viewed in the main image window D
142. st Rows then Columns vertical M Horizontal Lines oe I Only Black and White First Columns then Rows IV horizontal Cancel M Save settings to profile From this dialog box you can dictate how the measurements table will be printed You can also specify the order in which the grid cells should be printed Changing the page setup for tables 1 Set the margins or accept the defaults 2 Select or clear the Titles and Gridline options 3 Set the page order and orientation A preview of how the table will appear when printed can be seen at the top right of the dialog box 4 Click on OK to confirm your choices Note The margins you set are added to those used by your printer ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 37 4 The Common Interface 4 7 Toolbar 4 7 Toolbar This section describes the toolbar buttons that are common to all the modules In addition each module displays an additional set of buttons which are located in the Navigator These are discussed in each of the relevant module sections The main toolbar located just below the main menu bar provides quick access to the software s most frequently used tools and commands Command Toolbar Description Button Clicking the Open button displays the Open dialog box and allows you to open an existing experiment as described in Section 4 14 Opening an image Export i Click the Export button to copy the data or image that is displayed in the active
143. t accepting any text You will be able to enter text later You have now added an annotation that is indicated as the currently selected annotation by an outline box You can add more annotations by repeating the above steps To delete an annotation label click the right mouse button As an alternative to clicking the image to add a comment you can position both the arrowhead and the text box of your annotation with a single mouse interaction 1 Position the pointer at the location where you want the arrowhead left click and hold down 2 Move the pointer to the position where you want the text to be centred As you drag the pointer the annotation text entry box appears and stretches away from the arrowhead 3 When you release the button the text entry box changes to the in place editing mode Type in your text and press Enter Moving annotations To move an annotation 1 Position the pointer anywhere on the line between the arrowhead and annotation text box You might need to move the text box to see the line 2 The pointer changes to a hand indicating that you are in position If this does not happen you can use the zoom in function to increase the amount of line available to pickup the annotation 3 Drag the annotation to its new location ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 23 4 The Common Interface 44 Annotations 24 Moving part of an annotation You can also move the position of an annotation a
144. t and end of the graph in the upper pane Where truncation has occurred the line bordering the image is dotted Multi channel Images A picture of the chosen lane is displayed for each selected channel when you use the Channel Overlay viewing mode in a multi channel image Each picture has a coloured outline relating to its channel colour If the Single Channel viewing mode is selected only the picture of the lane from that channel is displayed e__ti_ _ _ As well as being able to resize this window you can adjust the relative size between the panes by using dragging the splitter bar between the two panes The profile pane has a minimum size ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 1D 5 5 5 3 1D Measurements window Measurements Window All Lane Measurements Miel Volume 23066 33 None 2396 83 Mone 66993 23 Mone 25737 38 None F4909 94 Mone 15134 00 None 44494 62 None 20904 21 None 3053 00 None The Measurements window displays all the analysis results Three different tables of data are available Each can be viewed by clicking on its tab at the bottom of the window You can use the Tables tab of View Options to select and order the different types of data fields that can be displayed for the bands in these tables The Selected Lane table displays the data fields for all the bands in the selected lane The All Lanes and Comparisons tables display the data
145. t that consists of various calculations from the detected colonies You select the fields to display in the window from the Tables tab see Section 7 5 2 for more information H Measurements Window 10 colonies This image contains 10 colonies 212 16 923 00 16 923 00 230 4 657 00 4 657 00 232 1 281 00 1 281 00 238 7 055 00 7 055 00 259 32 872 00 32 872 00 285 1 955 00 1 955 00 Scroll bars located at the bottom and right side allow you to scroll through your data ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 137 7 Colony Counter 7 5 Options 138 7 5 Options Click the Options button or View Options to display the options dialog box As with the other modules the Reporting tab has common parameters but the other tabs have specific parameters relating to this module The following sections describe the specific parameters for the Colony Counter module 7 5 1 Image tab in Colony Counter The Image tab allows you to change the various display settings in the Colony Counter module Options x Image Tables Reporting Detecting Image and colony display 3o The display of the image and colonies in the Image window E can be switched on and off M Show annotations M Show colonies M Show current colony Colony style Standard v Colony colours The colonies and the current colony can
146. table you can identify the newly re numbered colonies 7 7 6 Clearing All Colonies X Clicking on the Clear _ 1r _ button in the Navigator allows you to clear all previously detected colonies To clear individual colonies select the Delete Features button Ex message box asking for confirmation will prompt you before all colonies are deleted When you have finished editing colonies click the Next button in the Navigator ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 145 7 Colony Counter 7 8 Background Subtraction in Colony Counter 7 8 Background Subtraction in Colony Counter The software allows you to define the background volume across the images This background can appear in the image because of excess staining of the gel and other gel properties or the background can occur because of the process in which the image was captured Background subtraction is the process by which you remove from the measurements the part of the image s pixel intensity that is background intensity The various methods of background subtraction are selected by clicking a button in the Parameters tab of the Navigator Selected method Image Rectangle Mode non Spot None 7 8 1 Image Rectangle method To use the image rectangle background subtraction method 1 Click the Image rectangle button in the Parameters tab of the Navigator 2 Drag a rectangle in the image window that represents the background When you release the b
147. te command This places a copy of the object on top of the original that can be moved ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA Toolbox 8 Shape Properties You can use the Properties dialog box to e Edit the objects name enter a comment and choose to show the text or not e Change the font and orientation of the text e Change the pen size and colour used to draw the shape object e Rotate the object around its centre of gravity by changing the number of degrees by which it is rotated Grid 2 Properties El Name Show M Orientation abc C C 4 Bottom IgE a Font Comment Show D Orientation abe C B C Top Font Fen Rotate object Colour i Size fi fo Cancel To access the Properties dialog box you can either e Click on the object and then click Shape Properties from the Edit menu e Click on an object and press Alt Enter e Select Properties from the context menu after right clicking an object e Double click on an object when over an object boundary ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 163 8 Toolbox 8 7 Background Subtraction in Toolbox 8 7 Background Subtraction in Toolbox Background subtraction is the process by which you remove the part of the image s pixel intensity that is background from the measurements To begin the process click the Next button in the Navigator if you are in the Spot Definition mode or select the Background Subtract
148. ter performing analysis this window displays the data although it does not allow any analysis interaction You can view any channel of the current experiment in this window at any time The Second Image window only displays a single channel at a time Select the desired channel by clicking the channel buttons on the Second Image window toolbar The display commands for this window are the same as those on the Image window they are accessed from buttons on the Second Image window toolbar Refer to Section 4 11 1 Image window for more information To avoid confusion the analysis tools applied to an image in the main image window are not available in this window Note Annotations will only display in the main image window 4 11 4 Scrolling windows E a El Scroll box Scroll bars are used when the information being displayed is too large to fit on the screen The scroll bars are located at the bottom and right side of the image window They work in the same way as normal scroll bars but allow you to see the range that you are viewing In addition dragging the scroll box changes the start position of the range you are viewing you can also resize the scroll box Since the size of the scroll box reflects the amount of data that is shown in the associated window resizing the scroll box changes the display magnification Therefore if you are viewing an image and make the scroll box smaller less of the image is used to fill the wi
149. the Measurements window will be copied directly into an Excel spreadsheet Image data calibrated values of pixel intensities is also exported directly to Excel Each cell in the table represents one pixel Data is exported on a per channel basis An Excel workbook automatically opens and the measurement data will be pasted into a new workbook If Microsoft Excel is not installed use the Export to File command Edit Image This feature allows you to manipulate the image For more information refer to Section 4 8 Image Manipulation 4 3 3 Analysis menu The modes on the Analysis menu are unique to each analysis module For more information refer to each individual module For information on Annotations please refer to Section 4 4 Annotations ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA The Common Interface 4 4 3 4 View menu The View menu contains the following commands Zoom to Fit The Zoom to Fit command can be switched on or off by clicking this command When switched on the image will scale up or down to fit the window whenever the image window is re sized Contrast and Clicking either the Contrast or Colour command displays the Colour relevant dialog box Alternatively you can click the Contrast or Colour buttons on the toolbar For more information refer to Section 4 5 Contrast and Colour Options Clicking Options displays a dialog box containing various tabs Each tab allows you to select setting
150. the Microsoft documentation before attempting the step by step procedures ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 9 1 Introduction 1 2 The User Manual 10 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 2 Getting started 2 Getting started 2 1 Technical Support Should any problems arise with the installation or use of ImageQuant TL please contact Support at igtlsupport ge com or your local sales support office 2 2 Familiarise yourself After installation of your software you should familiarise yourself with the common interface sections of this manual The relevant sections of this manual outline the individual modules of the software and provide easy to follow procedures 2 3 Start software modules Start each module by either clicking a hyperlink or a button in the Control Centre ImageQuant TL Control Centre DER ImageQuant TL 1B gel analysis Analyze a 1D electrophoresis gel image Analysis Toolbox Analyze a dot slot blot microtiter plate or macroarray Colony Counting Count colonies or detect 2D electrophoresis spots Array analysis Analyze an image using area and profile based tools Online Help Look Up queries In the comprenensive reverence guide Also contained in this installation Fluors ep l Tools Alternatively you can open an image from within a module that is already open ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 11 2 Getting started 2 3 Start
151. the list that represents the values of your standard ES Lambda Hind III ES Phi X1 74 Hine I ES PhiX174 Hae III Note You can define new Standards or amend existing ones Refer to Section 5 12 3 Editing Standard Mappings Lists for more information 2 After you select your standard the list of its mapping values appears in the list box below the selector These values can be selected or deselected by clicking the check boxes at the side of each value 3 Select the lane that you want to designate as a standard by clicking on it in the Image window This lane should have all its bands detected by this stage The gel image should now show the selected standard with its mapping values attached to the bands The standard values can be re positioned on the bands by holding down the Left mouse button and selecting the band where the value has been assigned and dragging it to the required position Standard values can be individually added or deleted from the gel image by selecting or deselecting them in the mapping values list To remove all the assignments from a lane right click on the lane ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 101 5 1D 5 12 Molecular Size Calibration Multi channel Images You can only set standards on a multi channel image when using the Single channel viewing mode 5 12 2 Choosing parameters and performing calibration Before you can perform the molecular size calculation you m
152. the mouse button To move any other lanes repeat the steps above After all lanes have been moved to their new positions click the Accept button nf in the Navigator Alternatively right click in the Image window to accept the changes ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 1D 5 Adding Grimaces Because lane analysis is performed using the lane profiles ensure the bands of the lane are straight and perpendicular to the sides of the lane If the bands of the lane do not meet these criteria the software allows you to add grimaces to the lanes to compensate for the smiling effect A grimace is effectively a contour line of equal band position across a particular part of a lane The software calculates the band positions and lane profiles on the assumption that the lane warps uniformly between the horizontal start of the lane and the first grimace between grimaces and then between the last grimace and the bottom of the lane Example of where a grimace is needed In the section of the gel illustrated below the band is curved By putting a grimace over the band you can compensate for the curvature The following illustration shows the gel corrected by adding a Grimace Adding Grimaces 1 Click the Add Grimaces button in the Navigator oA Add Grimaces 2 Position the pointer at the approximate centre of the band and click the software adds the grimace to the lane You cannot add a grimace outside
153. top or bottom white handles of a lane The pointer changes to F indicating that the pointer is over a handle 3 Drag the handle left or right to change the angle of the lane 4 To bend a lane at any point other than the top or bottom add or delete handles 5 After you add an additional handle move the handle to the desired location which causes the lane to bend ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 85 5 1D 5 9 Lane Creation 86 Repeat these steps until you have aligned all the lanes Delete any handles that are not required If all the lanes are aligned correctly click the Accept button So in the Navigator Resizing lanes 1 Click the Bend Resize button in the Navigator l Bend Resize Position the pointer over one of the red handles The pointer changes to a double headed arrow dos Drag the corner handle away from the centre of the lane to make the lane wider or towards the centre to make the lane narrower As you move the handle the lane uniformly resizes about the centre When you finish the resizing click the Accept button Xo in the Navigator Alternatively right click in the Image window to accept the changes Moving Individual Lanes 1 Click the Move button in the Navigator P Move Position the pointer over the lane you want to move The pointer changes a to showing you that the lane can be moved Drag the lane to the new position and then release
154. tre 15 Copying 36 67 103 116 121 150 162 Creating a lane report 112 Current channel 77 experiment 77 lane 77 D Data Fields definitions 32 Data fields 32 De selecting lanes 60 Displaying lane names 69 lane numbers 69 molecular size 69 multi channel images 13 E Editing images 40 Editing Lanes adding grimaces 87 adding handles 85 adding lanes 85 bending and resizing lanes 84 bending lanes 85 deleting handles 85 deleting lanes 89 half lane width 88 moving individual lanes 86 moving the edges of abox 85 resizing lanes 86 Exiting 17 Experiment Overview 48 63 111 Export Lane Objects 59 Export Lane Profile to Clipboard 59 Export Lane Profile to File 59 Exporting to clipboard 18 to Excel 18 171 tofile 18 F Find average pixel intensity 129 bands 93 initial value 141 lowest pixel intensity 129 molecular size 100 peaks 94 G Glossary 167 Graph window 67 Grimaces 87 adding 87 adding handles 88 deleting 88 H Handles 84 85 86 87 126 150 152 161 167 Help activating the software 20 click for help 48 restoring default image 20 Image and Colony display 138 Image Editor window 41 Image files 55 Image Histogram 27 Image Manipulation 40 cropping 42 filtering 45 flipping 45 freeform rotating 45 opening images 41 reverting 42 rotating 45 saving the edited image 41 undoing edits 42 using markers 43 window 41 zooming 46 Image properties 17 Image window 51 62 118 137 153 Import
155. ts tables shpe PJ tee 7 Miscelaneout x and Y radii Select a value in pixels to size the X and Y radius The Y radius Te is only available when the spots are all the Slot shape Ca ee EE Select a shape from the list The choices are Circle Square or Slot Exclude from Select the check box if you do not want the measurements analysis calculated for the selected spots The various properties of the selected spots can be changed see below For more information refer to Section 6 6 7 Editing spot properties Edit Image Click the Edit Image button on the toolbar to display the Image Editor dialog box which allows you to manipulate the image This is a common feature to all the modules For more information refer to Chapter 4 8 Image Manipulation 116 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA Array 6 6 2 2 Analysis menu You use the Analysis menu to display the analysis modes Analysis 7 Spot Definition Background Subtraction Normalisation Presence Flagging Experiment Overview Annotate Image The following modes are discussed in the Analysis tools section e Section 6 6 Spot Definition e Section 6 7 Background Subtraction in Array e Section 6 8 Normalisation e Section 6 9 Presence Flagging For more information on the remaining commands Experiment Overview and Annotate Image refer to Refining your analysis results in Chapter 4 10 The Analysis tools and Chapter 4 4 An
156. ual size Page setup for tables The settings on this tab also affect the copying feature For more information refer to Chapter 4 6 3 Reporting tab ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 121 6 Array 6 6 Spot Definition 122 6 6 Spot Definition Multi channel Images In multi channel images the same individual spot or group of spots is applied across all channels You can also define the diameter of the spot before creation by setting the X and Y radius for the shape You can create edit or delete spots in both the Single Channel and Channel Overlay viewing modes Mo The basic steps involved in defining spots are 1 Select a grid type or create a new one 2 Create the grid either manually or automatically In addition you might want to perform any of these optional steps e Edit the grid properties after creation e Reposition the grid e Adjust the grid to allow for a skewed image e Reposition the individual spots e Resize the individual spots These steps are discussed below ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA Array 6 6 6 1 Defining the grid layout The Spot Definition dialog box allows you to accelerate the process of defining the spots on the image You can store parameters used for creating grids as a grid type that can be quickly selected from the Grid Type list at the top of the dialog box To begin spot definition you define the size and location of th
157. urements Window Lane Measurements Lane 7 Be x __ Band Base Pairs Volume Peak Peak Bkgnd Area Band Rt 8803 14 2789255 777 09 1868 83 54 00 74 69 0 05 23477 i 945293 376 11 1467 84 54 00 25 31 0 96 i 1524 79 2547 44 47 57 100 51 150 00 0 00 0 25 vr lt Selected Lane A All Lanes 4 gt The title bar of the window shows which lane the data originates from ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 1D 5 5 5 4 1D Graph window The graphical information LL Curve Lane 1 OI x calculated by the Molecular Size Calibration and Quantity 12 0 Calibration modes are ea 110 displayed in separate tabs in 00 this window e a a 50 The Graph window also shows a T which curve type was used in mo S the calibration 0 50 100 150 200 250 300 The MW curve shows the PEESO relationship of the position along the lane X to Molecular Weight pl or Base Pairs Y Log curve y 6154e0008 68x 4445 R2 Value 0 9931 BE MW Curve The Quantity Cal curve shows the relationship of Raw Volume Xx to Calibrated Volume Y 5 5 5 1D Report window The Report window displays reports about the analysis of the gel images You can print these reports but you cannot copy the reports to the clipboard Reports are not automatically updated if you change the analysis data Therefore you must re generate the report by selecting Create Lane Report from the Analy
158. ust set the molecular weight parameters in the Navigator 1 102 Select the Curve type from the list in the Navigator The curve you select will be used to determine the values between the mapped bands on the standard lanes and between the points of intersection of molecular size contours and the other lanes Now select whether to use Rf to propagate If this option is selected the molecular weight contours will conform to relative lane position not absolute To calculate the contours and curves after you select the Standard Curve type and Propagation Method click the Compute button M in the Navigator The software updates the Analysis window and displays a graph in the Graph window To clear the calibration from the gel and all assignments i e to restart assigning the mappings click the Clear button ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 1D 5 5 12 3 Editing Standard Mappings Lists The software provides you with a set of standard mapping lists for common standards You can use these with the gels or define your own To enter the editing mode click the Edit the Standards button on the Parameters tab in the Navigator The standards are edited from the Edit Standard dialog box that appears Mapping Units Molecular Weight i Mappings List FS 1KB lad ES BV BME ES BV BMH ES BV BML EE CANDIDA ES LAM ECO ES LAM EH ES LAM HAE ES LAM HIN3 ES SACCHARR FS SC
159. utton the software calculates the background level as the average intensity in the rectangle For each colony its area is multiplied with the background level which gives the colony s background The background value is subtracted from the colony s volume as measured without background subtraction The software updates the measurements table automatically Clearing an image rectangle You can clear the image rectangle by right clicking inside the rectangle This also removes the background values from the Measurements table Repositioning an image rectangle You can reposition a rectangle at any time by re drawing the rectangle as many times as desired The measurements are re calculated automatically when you release the button 146 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA Colony Counter 7 7 8 2 Mode of non spot method The Mode of none spot method works by first finding the rectangle that completely encloses each colony This rectangle is then expanded by a set number of pixels to give an area for examination the default is 45 pixels in every direction To use the Mode of none spot background subtraction method 1 Click the Mode non Spot button in the Parameters tab of the Navigator 2 Inthe Margin parameter text box in the upper Navigator type the number of pixels that you want the rectangle to be expanded by and click the Subtract button Alternatively you can change this value by using the up and down spin butto
160. utton in this mode The detect colonies process is controlled by a number of parameters both in the upper Navigator and in the Parameters tab 7 6 1 Basic Detection method The upper Navigator contains two parameters or Sas ensitrvit Sensitivity and Operator size i j Operator Size These sliders control the same parameter in the Parameters tab To detect colonies using these parameters e Drag to select an area of interest in the Image window The software performs automatic colony detection e Change the parameters by moving the Sensitivity and Operator size sliders When you release the slider the software performs automatic detection If the Measurements window displays the following message This image contains no colonies reset the sensitivity slider or re select the area to be measured Clicking the Initialise Sensitivity button E allows the software to find an initial value If you briefly pause when moving the sliders the On the fly detection feature allows you to observe the potential colonies This feature is selected by default and can be switched off using the Detection tab in the Options dialog box The Parameters tab includes the basic parameters described above and a number of advanced parameters These parameters can be changed by entering numerical values ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 141 7 Colony Counter 7 6 Detection 7 6 2 Setting the parameters To set the paramete
161. ver the lane image Clear the check box if you do not want to show the edges Display attributes Maintain As you change the horizontal area of interest of the profile aspect ratio graph the software zooms the lane to align the lane with the profile When this check box is selected the lane image is zoomed in both X and Y However zooming can make the lane too big or too small to be useful If you want the lane s height to be fixed at 1 1 clear the check box Show Select the check box to show the Molecular size annotations molecular size on the lane image Clear the check box if you do not want to display the Molecular size annotations Show overlays Select the check box to display an overlay on the lane image i e the profile band edges and the hatched rectangle between the edges Clear the check box if you do not want to display the overlay Show Current If you want to show the current lane only click the Show Lane only Current Lane only button Show If you want to show the current lane as well as additional Additional lanes click the Show Additional Lanes in Finish mode button Lanes in Finish You can select which additional lanes to display in the Lane mode Selection tab of the Options dialog box see Section 5 6 4 Note The additional lanes will only be visible in the Experiment Overview mode You can select this mode either from the Analysis menu or by clicking the Next button in the Navigator then clicking the F
162. ws you to set parameters The parameters in this dialog box allow you to customize your printed report by adding a title and including a logo from a previously saved graphic The parameters set using this dialog box affect the generation of all individual lane reports Report format s Different types of information can be displayed in the Report defauitloge bmp Browse W Show the following report title MyReportTitle Default Show analysis parameters Cancel Note Ifyou generate a report and then make changes to the report parameters using Options Reporting tab the current report is deleted You must generate a new report by clicking Create Lane Report from the Analysis menu ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 75 5 1D 5 6 Options In order to generate a report you must select a lane in the Image window The following describes how to select the parameters for customizing a report Description Instruction Include report Select this check box if you want to include a logo at the top logo loaded of your reports The logo must be in the bmp image file from file format To put a logo on the top of your report 1 Select the Include report logo loaded from file check box 2 To select an image file click Browse The Browse dialog box appears allowing you to search for and select an image file Show the Select this check box to include a title in your report You can foll
163. xel intensity Threshold i Ts Region of Interest Height 100 pixels 2 Zoom into an area of the image using the zooming tool al 3 Toset the Edge pixel intensity threshold right click the outer area of the feature as in the example below or type the threshold directly in the threshold text box ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA 159 8 Toolbox 8 6 Shape Definition 4 Click the centre of the feature The software automatically draws the autotrace shape If the Autotrace object is not drawn as expected try a different threshold 8 6 2 Lines The measurements for lines appear in the Line window You can choose among four types of line Line Click the Line button N ond then drag to draw a straight line between two points Polyline To create a connected line between two or more points use the polyline feature Click the Polyline button 2 e drag to create the first point of the polyline Continue clicking and dragging to add new points to the polyline When you have completed the polyline right click to add the final point Spline To create a smooth curve between three or more points on the image use the spline feature To create a spline click the Spline button fe kn then use the same method as for a polyline Freehand The freehand feature allows you to create a single line of any shape Click the Freehand button ef ee drag a line on the image The freehand line follows any movement y
164. you can cut the image down to contain only the area in which you are interested This is known as cropping Multi channel Images The cropping region is applied to all channels of a multi channel image C Setting the crop area Before using the cropping tool you must select an area on the sample image by following these steps 1 Click and drag out a rectangle on the image in the Image Editor The cropping area is indicated by green dotted lines Right clicking anywhere in the image cancels the selected area 2 Next select Image Crop to area Everything outside the selected area will be removed leaving the cropped area in the Image Editor To cancel this area once cropped select File Revert 42 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA The Common Interface 4 Moving the crop area To move the existing cropping rectangle place the pointer over one of the rectangle edges and then drag the rectangle to the new location Notice that the pointer changes to when over a line To change the shape or area drag the handles small boxes of the rectangle Notice the pointer changes to a two headed arrow line when over a handle You must be in Selection mode Ts to move or resize a cropping area For more information on moving a cropping rectangle refer to Moving a marker in Section 4 8 6 Using markers Saving cropping rectangles Cropping rectangles can be saved along with any marker For more informat
165. ysis tools are displayed in the Navigator allowing you to refine your analysis Modes can be selected in any order 4 9 2 Help hyperlink The Click for help hyperlink in the Navigator Help pane displays the online Help for the current analysis mode 4 9 3 Help pane A Help pane similar to the one below is displayed at the bottom of the Navigator Band Detection Band Detection can only be performed in single channel view Select Single from the main toolbar to analyse this experiment Click for help instructions Paame This area displays basic guidance relevant to the active module s analysis mode The text in red is relevant to multi channel images 48 ImageQuant TL 7 0 User Manual 28 9175 41 Edition AA The Common Interface 4 4 9 4 Parameters pane The Parameters pane displays the parameters for the current analysis mode of the active module It allows you to set parameters and start the analysis operations Peak Detection Noise reduction E Max Peak fo Edge parameters Automatic detection Fixed width 5 Instructions A Parameters If an unacceptable value is entered in a text box the text box will turn yellow If you have the software resized to a smaller region the Navigator displays the analysis tools is reduced to a Controls button Essais Clicking this button produces a popup window containing the Help and Parameter panes ImageQuant TL 7 0 User Manual 28 9175 41 Editio

Download Pdf Manuals

image

Related Search

Related Contents

Filtros de Línea Racohi  4011320980 EUROPEAN PLAY MANUAL.cdr  手動式 非接触型 ICカードリーダライタ  Samsung WD7000HK Combo con Big Capacity, 18 kg Manual de Usuario  Informations de propriété industrielle et commerciale  Samsung Galaxy S III GT-I9300 16GB Blue  Valueline VLAP24205B30  カタログ - 日本トリム  Chiffres et Lettres - p133  Philips Sonicare HealthyWhite HX6732/45 electric toothbrush  