Smoke Alarm User`s Manual

image

Contents

1. 2 In areas with high humidity like bathooms or areas near dishwashers or washing machines Install at least 10 feet away from these areas 3 Near air returns or heating and cooling supply vents Instdlat least 3 feet away from these areas The air could blow smoke away from the detector interrupting its alarm 4 In rooms where temperatures may fall below 3C or rise above 45C 5 In extremely dusty dirty or insect infested areas where loose particles interfere with smoke alarm operation A WARNING incorrect orientation will result in a decrease in operational effectiveness HOW TO INSTALL THIS SMOKE ALARM WARN ING Smoke alarm installation must be in accordance with the requirements of any national and local codes that may apply 1 From back of smoke alarm remove the mounting plate by turning it counterclockwise To later engage tamper resist feature twist out and set aside one of the pins molded into plate Both pins are exactly the same 2 Secure plate to ceiling or wall with mounting screws 3 Lift open battery pocket door 4 Connect new 9 volt battery to battery connector inside battery pocket Be sure battery is securely connected Red LED may blink briefly when battery is installed 5 Close battery pocket door snapping it into place 6 Position smoke alarm to mounting plate and turn clockwise to lock into place To engage tamper resist feature insert pin into notch on edge of smoke alarm after alarm is pr
2. exit 3 Teach all household members to touch the door and use an alternate exit if the door is hot Instruct them not to open the dor if the door is hot 4 Teach household members to crawl along the floor to stay below dangerous smoke fumes and gases 5 Determine a safe meeting place for all members outside the building WHAT TO DO IN CASE OF FIRE 1 Do not panic stay calm 2 Leave the building as quickly as possible Touch doors to feelf they are hot before opening them Use an alternate exit if necessary Crawl along the floor and do not stop to collect anything 3 Meet at a pre arranged meeting place outside the building 4 Call the fire department from outside the building 5 Do not go back inside a burning building Wait for the fire department to arrive These guidelines will assist you in the event of a fire However to reduce the chance that fires will start practice fire safety rules and prevent hazardous situations TROUBLESHOOTING i WARNING DO NOT disconnect battery to quiet an unwanted alarm This will remove your protection Fan the air or open a window to remove smoke or dust DO NOT INSTALL SMOKE ALARMS 40CM 4 CEILING Mn ANYWHERE IN THIS AREA BESTHERE NEVER HERE ACCEPTABLE HERE HORIZONTAL DISTANCE 1 Near appliances or areas where normal combustion regularly occurs kitchens near furnaces hot water heaters Use specialized smoke alarm with unwanted alarm control for this areas
3. the unit will emit a load pulsating alarm and a RED indicator 111111 light LED will be flashing quickly until the air is clear TESTING THE SMOKE ALARM 1 Test each smoke alarm to be sure it is installed correctly and operating properly 2 The push to test button accurately tests functions Do not use an open flame to test this smoke alarm You may ignite and damage the smoke alarm or your home 3 Test smoke alarms weekly and upon returning from vacation or when no one has been in the household for several days 4 Stand at arm s length from the smoke alarm when testing TEST ALL SMOKE ALARMS WEEKLY BY PERFORMING THE FOLLOWING STEPS 1 Firmly push the TEST button or use the remote testing function the smoke alarm will sound a loud beep The alarm will stop sounding after releasing the TEST button 2 If smoke alarm does not sound please retest the smoke alarm DANGER 1f the alarm sounds and smoke alarm is not being tested the smoke alarm is sensing smoke THE SOUND OF THE ALARM HORN REQUIRES YOUR IMMEDIATE ATTENTION AND ACTION MAINTENANCE AND CLEANING In addition to weekly testing this smoke alarm requires yearly battery replacement and periodic cleaning to remove dust dirt and debris BATTERY REPLACEMENT Replace battery at least once a year or immediately when the low battery signal sounds every 45S Batteries should be replaced regularly as necessary WARNING Do not use any other type of battery except as specifie
4. R A D O U R S S M S Smoke Alarm User s Manual Please read and save this manual WIRELESS PHOTOELECTRIC SMOKE ALARM MODEL WS588P AF2 WS588P V3E EN 50130 4 A EN 61000 6 3 T V EN 14604 EN 14604 Photoelectric smoke alarms are generally more effective at detecting smoldering fires which smolder for hours before bursting into flame Sources of these fires may include cigarettes burning in couches or bedding MAIN FEATURES DC operated Wireless Photoelectric Type Smoke Alarm Photoelectric sensor for slow smoldering fires Test Weekly button Non radioactive technology for environmental friendly High and stable sensitivity Quick fix mounting bracket for easy installation Fitting and battery tamper resist feature LED operation indicator Extra loud alarm sound over 85 dB Low battery and battery missing warning indicator V Vv VV VV VY VW WY WW W Auto reset when smoke clears SPECIFICATION Model Number WSS88P AF2 WS588P V3E Detection Type Photoelectric Chamber Power Source 9V DC Battery Working frequency 433 868MHz Emission distance gt 150mm open space Standby Current 18uA max Alarm Current 18mA max 85 Decibels at 3 meters Operation Temperature 5 Cto 45 Ambient Humidity 10 90 3 0 6 0 0bs m Compact size 110mm diameter Alarm Sound Level Sensitivity to Smoke V N N NN NNN WT WW WW W IMPORTANT SAFETY INFORMATION 1 This smoke alarm requires constant working 9 volt battery tooperate p
5. d in this manual Do not use rechargeable batteries A CAUTION Explosion could happen if battery is incorrectly replaced 3 For installation observe all local and national electrical building codes 4 This smoke alarm is designed to be used inside a singleroom only In multi room buildings each individual living unit should have its own smoke alarms Do not install in non residential buildings And this smoke alarm is not a substitute for a complete alarm system 5 Smoke may not reach the smoke alarm for many reasons For example if a fire starts in a remote part of the home on another level in a chimney wall roof or on the other side of a closed door smoke may not reach the smoke alarm in time to alert household members A smoke alarm will notpromptly detect a fire except in the area or room in which it is installed 6 Smoke alarms may not alert every household member every time The alarm sound is loud in order to alert individuals of a potential danger However there may be limiting circumstanceswhere a household member may not hear the alarm Le outdoor or indoor noise sound sleepers drug or alcohol usage the hard of hearing etc If you suspect that this smoke alam may not alert a household member install and maintain specialty smoke alarms Household me mber must hear the alarm s warning sound and quickly respond to it to reduce the risk of damage injury or death that may result from fire If a household member is hearin
6. g impaired install special smoke alarms with lights or vibrating devices to alert occupants 7 Smoke alarms can only sound their alarms when they detect smoke Smoke alarms detect combustion particles in the air They do not sense heat flame or gas This smoke alarm 1s designed to give audible warning of a developing fire However many fires are fast burning explosive or intentional Others are caused by carelessness or safety hazards Smoke may not reach the smoke alarm QUICKLY ENOUGH to ensure safe escape 8 Smoke alarms have limitations This smoke alarm is not foolproof and is not warranted to protect lives or property from fire Smoke alarms are not a substitute for insurance Homeowners and renters are responsible for insuring their lives and property In addition it is possible for the smoke alarm to fail at any time For this reason you must test the smoke alarm weekly and replace every 10 years Note For best protection we recommend that you install a smoke alarm in every room A 0 SMOKE ALARM PLACEMENT O ancien Ti Typical single story home Install a smoke alarm on the ceiling or wall inside each bedroom and in the hallway QO 0 outside each separate sleeping area If a bedroom area hallway is more than 30 feet SINGLE STORY RESIDENCE APARTMENT long install a smoke alarm at each end N If there is a basement Install a smoke alarm on the basement ceiling at the bottom of the stairwell Typical Multi story or split le
7. operly positioned in base 7 Push test button to test smoke alarm See TESTING THE SMOKE ALARM Problem Possible cause Solution Not all of the Devices may not have power Check that battery is properly attached to connector alarms accessories connect with the control panel The smoke alarm 1s far away from the Install the smoke alarm close to the control panel control panel Smoke alarm beeps with the Low battery red LED flash every 458 Replace battery See battery replacement in the maintenance and cleaning section Smoke alarm beeps every 45S The smoke alarm has reached its end Replace the smoke alarm with a new one but the red LED does not of life flash Manufacturer Xiamen Vs Top Electronics Co Ltd 6th floor Jinzhongda Park No 666 Yangguang Road Xinyang Industrial District Hatcang Xiamen China Tel 0086 592 6017700 E mail info vs top com Website www ortentalert com
8. pressed when the battery has been fitted 5 Using the Push to Test button test the smoke alarm to verify 9V DC battery See TESTING THE SMOKE ALARM 6 Reattach the smoke alarm to the mounting plate by turning the smoke alarm clockwise until it snaps into place 7 Test the smoke alarm See TESTING THE SMOKE ALARM CHOOSING A REPLACEMENT BATTERY The unit requires one standard 9V battery The following batteries are acceptable as replacements Golden Power 6F22 Megaton 6F22 New Leader 6F22 Gold Peak 1604 Eveready 522 1222 Golden Power G6F22 Golden Power GL6F22A CLEANING Clean the smoke alarm at least once a month to remove dust dirt or debris Using the soft brush or wand attachment of a vacuum cleaner vacuum all sides and cover of smoke alarm Be sure all the vents are free of debris If necessary use a damp cloth to clean smoke alarm cover IMPORTANT Do not attempt to remove the cover to clean inside the smoke alarm This will void your warranty PRACTICE FIRE SAFETY If the smoke alarm sounds its alarm horn and you have not pushed the test button it 1s warning of a dangerous situation Your immediate response 1s necessary To prepare for such occurrences develop family escape plans discuss them with all household members and practice them regularly 1 Expose everyone to the sound of a smoke alarm and explain what the sound means 2 Determine two exits from each room and an escape route to the outside from each
9. roperly This smoke alarm WILL NOT work if the battery is removed drained or improperly connected DO NOT ue any other kind of battery except as specified The Test button accurately tests all smoke alarm functions Do not use any other test method Test smoke alarm weekly to ensure proper operation 2 DO NOT remove or disconnect battery to quiet unwanted alarms This will remove your protection Open windows or fan the air around smoke alarm to silence it HOW TO SET THE SMOKE ALARM INTERCONNECT WITH CONTROL PANEL 1 Find the 6 position dipswitch located on the back of each device DIP switch function The 1 6numertc is for coding total 64 coding The protection zone is composed by 2 bytes The high byte is fixed at 170 the low byte is as 6 set by the dip switch starting from 000 to 063 2 Using a pen or pencil change the switches in each of the wireless devices 000000 3 The protection zone only can be read when press test button to test smoke alarm or the alarm is powered on 100000 4 Please refer to the manual of control panel to add the alarm CAUTION Due to the loudness of the alarm always stand at an arm s length M O000 B away from the unit when testing pus ae OPERATING YOUR SMOKE ALARM 101111 Once the smoke alarm has been installed A RED indicator light LED should flash approximately once a minute to indicate the battery is healthy and the unit is operating 01 T properly If smoke is detected
10. vel home Install a smoke alarm on the ceiling or wall inside each bedroom and in the hallway outside each separate sleeping area If a bedroom area hallway is more than 30 feet long To install a smoke alarm at each end Please install a smoke alarm on the top of a nan Be i MULTI STORY RESIDENCE first to second floor stairwell KEY Minimum required smoke alarm locations ORecommended additional smoke alarm locations A Smoke alarms with hush features recommended for additional protection IMPORTANT SMOKE ALARM PLACEMENT AND EXCEPTION INFORMATION 1 Install a smoke alarm as close to the center of the ceiling as possible If this is not practical mount no closer than 4 inches from a wall or corner Also if local codes allow install smokealarms on walls between 4 and 12 inches from ceiling wall intersections 2 Install a minimum of two smoke alarms in every home no matter how small the home 3 Install a smoke alarm in each room that 1s divided by a partial wall either coming down from the ceiling at least 8 inches or coming up from the floor 4 Install a smoke alarm in lived tn attics or attics which house electrical equipment like furnaces air conditioners or heaters 1 Tum smoke alarm counterclockwise to detach it from the mounting plate 2 Gently pull down smoke alarm 3 Remove battery from the compartment 4 Insert a new 9 volt battery to connector NOTE POLARITY OF CONNECTIONS Ensure the metal tab is fully de