1. U a EW GmbH Stettiner Str 38 D 33106 Paderborn Padin 4 Art no MB PADIN4 Valid from M Bus generation 20 4 channel status and error module for M Bus Contents PRUNGON MOC S CUPO Mp 2 om lem ea AAA o o mmr tee seen 3 5 GOMMeCING E 3 ae 012 8 ae big ow ore rear 4 2 3 MOUNT iii ESTE ARATA cen A ARA 4 3 Parameterization using MBCONE cccsscccseeeceeeeceeeecseeecseeeceaeesseessesessaeessaeesseeeeas 5 3 1 Stallone noel eones ctacida 5 ARA ee UNO en ee ee 5 AS A Meet ie Rete em er orn ex Bo Oreo ae Ne ene ee ere eon 6 3 once Al ss 9 4 MEBUS Telegram Sii AAA AAA 11 So o ene ren eer ct mente st E ert ere ere cre terre rene ir 13 Padin 4 User Manual 20 09 01 Version 1 2 Relay GmbH Stettiner Str 38 D 33106 Paderborn 1 Functional description Four contact states can be read through the M Bus with Padin 4 For example fault feedbacks or status indicators from electrical equipment in industry or from alarm devices such as windows and door sensors can be scanned and checked When polled from the M Bus master the four inputs from the Padin 4 are scanned and output in the answer protocol The inputs are effectively debounced by majority decision after being scanned five times at an interval of 1ms each The parameter address ID number and medium of the M Bus protocol can be set from the M Bus with the MBCONF software as required These parameters are stored permanently in an EEPROM and
2. Write sends the current options to the device The PadIn 4 changes the options only if the write protect is deactivated It is recommended to read the data after writing and check it Port state Shows the current state of all ports as hexbyte and for each port A bit 1 or a marked port no indicates a closed contact at this input Note 1 Please press first the button Connect to meter after connecting a new M Bus device Afterwards all sheets are refreshed 20 09 01 Version 1 1 Padin 4 User Manual u gt EW GmbH Stettiner Str 38 D 33106 Paderborn 4 M Bus Telegrams 1 General e Communications according to EN1434 3 e Transmission rates 300 2400 and 9600 Bd with auto baud detect e Primary and secondary addressing with wild cards e SND NKE E5 SND_UD E5 REQ_UD2 RSP_UD is supported 2 Definitions e All values are specified in hexadecimal e Empty fields in the Contents line are variable e Index 1 designates the least significant byte in fields containing several bytes 3 RSP_UD Telegram pee i 2 34 5 6 7 8 ICE Name start Length Length stat c A Ct tot nat 68 18 13 68 os 7 c 4 r ake eee Remarks e Manufacturer MAN REL 48AC e Generation GEN 20 2F first software revision is 20 e Status Bit 7 MSB 1 protected 0 unprotected e Input current state of inputs one bit per port logical 1 contact is closed Bi
3. can be protected against reprogramming by the user This protection can only be removed by opening the sealed housing The housing of Padin ist suited for mounting on wall or DIN rail according to DIN EN 50022 i VSS 20 09 01 Version 1 1 Padin 4 User Manual Y EW GmbH Stettiner Str 38 D 33106 Paderborn 2 Installation and Setup The device is delivered with a basic configuration address 0 unprotected The user must parameterize it to fulfil the needs of the installation 2 1 Connecting diagram M Bus e Signal generator with floating contacts reed contacts are connected independent of polarity to the terminals Int In1 to In4 In4 e Signal generators with photocoupler or galvanic insulated transistor outputs must be linked to the terminals Int Ini to Ind In4 using the correct polarity Padin 4 e tis not possible to use active signal generators voltage sources Digital Inputs e The M Bus connection is made with the terminals M M There is second pair of M Bus terminals for linking the M Bus to other devices The following drawing shows a typical application of the PadIn4 Movement detectors Smoke detectors Te N Bus i me i A A Pasesoss 45 WZ UAZ E ww E E tm ee vg oe Te ey med Padin 4 Window or door sensors Gas detectors Padin 4 User Manual 20 09 01 V
4. al generators Potential floating insulation to earth gt 1MQ Resistance open gt 100kQ closed lt 100 Capacity incl cable lt 10 nF Length of cable lt 3m Inputs of Padin 4 Contact voltage 3 0V to 3 6V typical 3 3V Contact current 3 0mA to 3 6mA typical 3 6 mA Guaranteed debounce time 2 0ms Working resistance 1kQ between In and 3 3V Terminals Wires screw terminals for wires with diameter up to 4 mm Colour green similar to RAL 6018 M Bus 2 pairs linked together Inputs 4 pairs Protective class IP20 Padin 4 User Manual 20 09 01 Version 1 2 En 5 GmbH Stettiner Str 38 D 33106 Paderborn M Bus physical characteristics M Bus quiescent current typ 1 25 mA max 1 5mA 1 unit load Space 0 bit current quiescent current typ 14 mA M Bus interface TI TSS721 with 2 x 215Q protection resistors 20 09 01 Version 1 1 Padin 4 User Manual u gt EW GmbH Stettiner Str 38 D 33106 Paderborn Padin 4 User Manual 20 09 01 Version 1 2 En 5 GmbH Stettiner Str 38 D 33106 Paderborn Notes 20 09 01 Version 1 1 Padin 4 User Manual
5. ccording to EN 1434 3 can be read and programmed using an optical reading head e g PadPuls M4 MAL The software always reads the data after writing if this option is activated useful for checking the correct programming En 5 GmbH Stettiner Str 38 D 33106 Paderborn Log Window The so called log window is always visible All M Bus communication steps are logged in this window Data is displayed in hexadecimal notation It is possible to mark outputs in the log window and copy them with the keys CTL C to the windows clipboard Then the data can be easily imported to any text editor for documentation As soon as the max storage capacity of the window is achieved no more data is logged If you want to log further you must delete the logged data The following buttons are also always visible Erase log clears all outputs inside the log window Exit terminates the program and stores the current setting of serial port port no into the INI file 8 amp 8 20 09 01 Version 1 1 Padin 4 User Manual 3 3 Sheet Padin4 fil RELAY MBECONF M Bus Configuration W1 40 Padind Prim address 11 Info ID sec ade 111011071 Medium Eos Fort state Pinte protection ry Mil Fe hop 4 Write protect Read write COM Fort CO Baudrate 2400 Nem M Bus 200 at 2400 Baudrate sEuf a GE Buf 2 13 E GE eT These sheet shows the actual settings and
6. ed as a sheet system The sheet Info contains general options of the communication with the M Bus device to be configured In this sheet the user can select the serial port of the PC the baudrate of the PC the baudrate of the M Bus device and the M Bus primary address which is used for communication After a successful connection with the M Bus device further manufacturer information is shown in the sheet Info and additional device specific sheets are displayed Padin 4 User Manual 20 09 01 Version 1 2 En 3 3 Sheet Info HN RELAY MBECONF M Bus Configuration 1 40 LOM Part com M Bus 254 Generation T ZWEI optical mode Baudrate 2400 y Manufact REL Aen 2400 Type 16 Erase log New M Bus Baudrate Current information about M Bus and software updates can be found on our internet site k WA RELAY DE 5 GmbH Stettiner Str 38 D 33106 Paderborn Please send your questions and comments to our EMAIL address mallto intotoRe Lay DE Address A RISES eevee EB MONADA Autom readout Connect to meter El HL Exit Es This sheet shows some photos of supported M Bus devices from the product range of the Relay GmbH the PadMess GmbH and further manufacturer Here are also links to the Internet page from which the current version of the program can be downloaded and to the email address for criticism and suggestions to the program The low
7. er third of this card is likewise visible in every other card Here the following input fields and buttons are always attainable COM Port Baudrate is the serial port of the PC to which the M Bus level converter is connected The selected port will be saved in an INI file and will be restored on startup Therefore the COM Port has to be configured only once is the transmission speed of the serial port of the PC used for parameterization Possible selections for this used M Bus baudrate are 300 2400 or 9600 baud Attention Baudrates of more than 2400 baud are not supported by all M Bus level converters which 6 20 09 01 Version 1 1 Padin 4 User Manual New M Bus Baudrate M Bus Address Connect to meter Manufact Generation Type State ZVEI optical mode Autom readout Padin 4 User Manua Bus State will then be refreshed New sheets are generated depending on manufacturer and type of the M Bus device One sheet appears in case of Padin 4 is an item that shows the 3 letter manufacturer code after successful reading Connect to meter The item is read only shows the software revision of the firmware of the connected M Bus device The item is read only shows the type here PadIn4 of the connected device This item is read only shows the M Bus state of the connected device This item is read only lf this option is activated devices with an optical interface and protocol a
8. ersion 1 2 En 5 GmbH Stettiner Str 38 D 33106 Paderborn 2 2 Opening the case The case cover can be removed from the lower housing half with the help of a small screwdriver The screwdriver is placed as in the drawing into the small opening at the cover side After light moving of the screwdriver in the displayed direction the cover can be taken off a gt A AO AA 2 3 Mounting On the back of the housing there is a special mechanism for mounting the device on a DIN rail according to DIN EN 50022 This mechanism can be removed turned over and fixed on the wall with two screws Afterwards you can mount the device without using a rail The following figures show the two options Rail mounting Wall mounting 20 09 01 Version 1 1 Padin 4 User Manual u gt EW GmbH Stettiner Str 38 D 33106 Paderborn 3 Parameterization using MBCONF The configuration of the device must be adapted by the customer to the respective installation We include the software MBCONF with delivery You can get the old software PADCON for MS DOS or MS Windows 3 1 systems from our web page www relay de 3 1 Installation The software MBCONF for configuration of the status module is a 32 bit application which can be executed on IBM PC compatible computers under the operating systems Windows 95 98 NT 4 0 The d
9. esktop PC or laptop must have a free serial RS232C interface to connect the M Bus level converter The Padin 4 to be parameterized must be connected directly i e as only M Bus device to the M Bus output of the level converter Please start the file MBCONF_SETUP EXE from Windows Explorer or via Start Execute to install the software from version 1 40 up Subsequently you select the language of the installation procedure The setup software can create a program group and a link on the desktop on demand You can then execute both versions for German and English language either from start menu or desktop 3 2 Operation After program start the user operates the software according to the Windows conventions with the mouse or the keyboard If you stay with the mouse on a button or an input field then a hint to its function appears Light grey fields and boxes are not capable for editing All input fields and buttons have an underlined letter The function can be activated by simultaneous pressing of the keys ALT and the respective letter Within dialogs the cursor can be moved with the keys TAB or SHIFT TAB forwards and back SPACE activates or deactivates selection boxes Multiple selection boxes arrow at the right edge can be activated with U The user then selects an entry with U and fT By pressing RETURN the selected entry is taken over With ESC the selection box is left without transfer The program is arrang
10. t O LSB input 1 Bit 1 input 2 Bit 2 input 3 Bit 3 input 4 Padin 4 User Manual 20 09 01 Version 1 2 En GmbH Stettiner Str 38 D 33106 Paderborn 4 Configuration telegram ete 2 3 mat ee 12 12 T _ Notes e Variables to be configured can only be changed when no write protection is set e Grey fields can be altered e Padr Address range 0 250 e ID ID number BCD e MED Medium e other items MAN and GEN will be ignored e coding of ID MAN GEN and MED according to the fixed header in the variable data structure of EN1434 3 e the optional block DIF2 Protect activates protection 5 Telegram to set the write protection _ 1 2 4 5 7 als lm m mtl es os os o os sopor fs 6 The write protection can only be reset by pressing the pushbutton on the circuit board 20 09 01 Version 1 1 Padin 4 User Manual lay ale GmbH Stettiner Str 38 D 33106 Paderborn 5 Technical Data Housing Rail according to DIN EN 50 022 A _ optionally for wall mounting El WxHxD 55x75x110 mm Relay Protective class IP 40 ABS plastic light grey similar to RAL 7035 Environment Operating temperature 0 60 C Storage temperature 25 C 60 C Humidity non condensing 10 70 EMC data CE mark Emission DIN EN 50081 1 Immunity DIN EN 50082 2 ESD DIN EN 61000 4 2 Specifications to the sign
11. values of the respectively pulse channel port of the Padin 4 The following input boxes and buttons are used to change the M Bus Address Manufach HEL 54 T ZWEI optical made OG a a a a Generation 20 M Bus State Type Autom readout Connect to meter Erase log HL Ext al Z params of the pulse adapter Prim address ID sec adr is the M Bus address of the Padln4 Values between 1 and 250 can be entered in this field for new assignment of the address After pressing the Write button the software programs this primary address and further variable settings on this sheet into the M Bus device is the 8 digit M Bus ID identification no which is also used for secondary addressing of the device Medium describes the measured medium of the connected meter Examples Oil Water Heat Electricity Padin 4 User Manual 20 09 01 Version 1 2 PQ En 5 GmbH Stettiner Str 38 D 33106 Paderborn Write protection is marked if the device is protected against programming Then you cannot configure the adapter The protection can be removed after opening the sealable housing and pressing the Unprotect pushbutton Write protect Transmits a command to the Padin 4 to activate write protect The Padin 4 then allows no further configuration It is protected against unnoticed manipulation Read reads the M Bus device and refreshes the data on the selected sheet