NUFLO MC-II Flow Analyzer QuickStart Data Sheet

image

Contents

1. cameron O pie S NUFLO MC II Flow Analyzer CE Approved QuickStart Mount the MC II Direct Mount _ MC II FLOW ANALYZER For remote mount Instructions see the MC II User Manual TOTAL BBLS 1 Plug the MC II cable connector into the pickup and turn the swivel a nut clockwise until the connector RATE BPD is fully inserted into the pickup and m pn the swivel nut is hand tight SOO aS 2 Loosen the locking screws that secure the base MC II mount 47 NuFlo 3 Position the MC II on the flow meter carefully pulling excess signal cable through the strain relief cord connector on the side of the upper mount Forcomplete 4 Thread the base of the mount onto J instructions the conduit adapter of the turbine a i nee meter and tighten two extra rounds S nae CE Approved after it is hand tight DO NOT allow UserManual the upper mount and MC II readout Part No to turn while tightening the base to ii 9A 50165011 avoid damaging the signal cable 5 Tighten the outside nut of the strain relief cord connector on the upper mount with a 15 mm open end wrench to prevent cord slippage 6 If necessary adjust the MC II read out for best viewing Loosen the nut on the bolt that holds the MC II readout on the upper mount tilt the unit to the desired angle and retighten the nut CAMERON MC II FLOW ANALYZER TOTAL BBLS RATE BPD mooo Ek AT 3 Enclosure 47
2. 3 9V l 1 82 mA P 1 77 mW C 0 L 0 appear in the top display and the version number MAY BE 991 OR 458 SERIES NUFLO FLOWMETER OR ANY APPROVED DEVICE WITH THE FOLLOWING MAXIMUM ENTITY i Eot En9 of the firmware will appear in the bottom display m The tot Eng menu will then appear in the top m barrels display and the default volume unit bbL will RATE appear in the bottom display 2 Press INCREMENT until the desired unit of gallons oA measure appears in the bottom display Press a ENTER STEP cubic meters nnd If you select a preprogrammed unit bbl gal T m liter Pu P gAL will appear in the top liters LE display Go to Step 3 for instruction on enter RATE ing your flowmeter s calibration factor in user defined noes pulses per gallon The MC II will automatically calculate the divisor Ifyou select uSEr Ent diV will appear in z Ent d iu the top display Enter a calculated divisor aes in terms of specified unit from right to left aE MANIEIRA RAN Press INCREMENT to select each digit press a ENTER STEP to advance to the next digit Proceed to Step 4 RATE CAMERON oO falc aaa et 3 Locate the flowmeter calibration factor pulses per gallon on a plastic tag attached to the meter Enter the number as follows a Press DEC POINT repeatedly to position your decimal point for the calibration factor b En
3. NuFlo Captive screws L Cord Front plate Upper mount Be connector Lower mount Locking screw Pickup connector Desiccant packet Enclosure Battery Signal cable Plastic retaining strap Terminal connectors Z Battery terminal MEASUREMENT SYSTEMS Install Field Wiring Connect the battery and flowmeter signal cable as shown at right CAMERON I S BATTERY P N 9A 90099000 FLOWMETER INPUT CHASSIS GROUND CHASSIS GROUND 9A 100005109 991 43179 REV O CAUTION The lithium battery that powers the MC II is sealed but a battery leak could expel toxic fumes into the MC II enclosure Before opening the enclosure make sure the enclosure is in a well ventilated area and avoid breathing fumes that could be trapped inside See Appendix A of the MC II Flow Analyzer User Manual Part No 9A 5016501 1 for instructions on battery disposal and a link to the MSDS sheet for the MC II battery TOTALIZER BOARD CONNECTIONS CLASS I ZONE 1 GROUP IIC T4 HAZARDOUS AREA DOTTED LINES INDICATE OPTIONAL SHIELDING SIGNAL 2 A TURBINE MAGNETIC PICKUP Calibrate the MC II The following information is needed to calibrate the MC II e unit of measure for volume e flowmeter calibration factor pulses per gallon e unit of measure for flow rate 1 Press and hold ACCESS for 3 seconds then release to enter Calibrate mode Prog no will PARAMETERS U
4. abled Press ENTER STEP If you select YES a data entry field will appear in the bottom screen Enter a numeric password contain ing up to six digits Remember your password You will be asked for it each time you press ACCESS to enter the Calibration mode or RESET to zero the total 7 The SEt tot preset total menu will appear To bypass this menu and complete the configuration press ENTER STEP To preset a total press INCREMENT to toggle the setting to YES then press ENTER STEP Enter the digits of the total right to left pressing INCREMENT to select each digit and pressing ENTER STEP to save the selection When the last digit has been entered and saved the prompt SAVING will appear in the lower display while the calibration set tings are saved to nonvolatile memory The calibration process is complete MEASUREMENT SYSTEMS Formerly NuFlo Measurement Systems e Barton Instrument Systems Caldon Inc HOUSTON 281 582 9500 NORTH 1 800 654 3760 ASIA 603 2287 1039 EUROPE 44 1243 826741 HEAD OFFICE AMERICA PACIFIC P MIDDLE EAST ms us c a m com ms asiapacific c a m com amp AFRICA ms uk c a m com USA CANADA UK SCOTLAND CHINA UAE ALGERIA MALAYSIA SINGAPORE www c a m com flo CAMERON Part No 9A 50165012 Rev 01
5. ter the digits from right to left beginning with the flashing digit to the far right c Press INCREMENT to select digits between 0 and 9 or press and hold INCREMENT to scroll the digits Press ENTER STEP to save the selection Repeat this step to enter all six digits If your calibration factor AE Eng is less than six digits in length bai enter 0 for remaining digits per day 5 P d TOTAL When the last sixth digit is saved the calibration factor will gallons 4 lt unit gt be saved in the MC II s memory per minute J P an PEr JAS per day and rAt Eng will appear in the dubie meters it top display per day and P d P a a hoi 4 AttherAt Eng prompt select liters 5 anii a unit of measure for rate Press per minute 15 70 Pr ANIA per minute INCREMENT until the desired unit Se eer lt unit gt appears in the bottom display If Er SEC per second you selected a user defined unit of measure for volume in Step 2 the rate options will be per day per hour per minute or per second Press ENTER STEP PULSE will appear in the top display 5 Deselect the Pulse Output option by pressing ENTER STEP to accept the default setting OFF CodE will appear in the top display 6 Enable or disable the password protected security feature Press ENTER STEP to retain the default NO setting or press INCREMENT to toggle the setting to YES password protection en