Home

DS-781MKB User manual_KC-10

image

Contents

1. 9 4 1 1Keyboard ID setup 9 4 1 2 Keyboard baud rate setup 10 4 1 3 Navigation key adjust 10 4 1 4 Display Keyboard information 11 4 2 Dome setup 11 4 2 1 Pre set setUp 11 4 2 2 Dome Scan setUp 12 4 2 3 Pattern setUp 12 4 2 4 Tour setUp 13 4 3 Protocol setup 4 4 Exit Keyboard menu 5 Appendix
2. 14 5 1 RS485 Bus general knowledge 14 5 2 Keyboard shortcut instruction 16 6 Keyboard menu index 18 1 Summary The keyboard is a universal keyboard of security monitoring series which can control the ball type integrated camera of all kinds protocols matrix which has been equipped with Joystick which can control the revolving of the camera and the zoom magnification of lens with the LCD screen and the function of back light which can display the current operation order the control protocol name the current dome ID the current monitor ID and the state of joysticks The user can control the CCTV system more easily with the joystick and the LCD screen 1 1Notice Please read the manual carefully and reserve it Please advert to the notice in manual Please don t place the keyboard in the moist place 1 2 Function and Characteristic Rs485 Bus Line and a keyboard can connect 31 domes at most in the direct control mode can be compatible with all kinds of protocols can control the Iris Focus and Zoom can set and call the preset run the scanning the pattern and the tour can control the matrix and through which can control the dome indirectly
3. High speed dome TOUR or directly press TOUR TOUR to start the Tour Input 95 and Preset to call 9 5 PRESET High speed dome Eu 4 217 the menu P SHIFT Jand SET Jto call SHIFT SET Matrix iene de ce PELCO the matrix menu Matrix Press PREV skip to the Mode previous dome hold on 2sec on PREV Matrix PREV to continuously skip the sixteen domes of connection matrix forwards Press NEXT skip to the previous dome hold on 2sec on NEXT Matrix NEXT Jto continuously skip the sixteen domes of connection matrix backwards Stop Matrix Stop switch After program press Enter to ENTER Matrix ER confirm Input monitor ID press Cam to N MON Matrix o select object monitor 1 Keyboard setup 2 Dome setup 3 Protocol setup 4 Exit menu Exit menu CamID 001 Mon ID 001 Protocol Factory Baudrate 9600bps 123 sft Keyboard setup Set KB Parameter Set KB ID Set baudrate 1 SetKB Parameter 1 Set KB ID Input KB ID 1 2400bps 2 About Keyboard P 2 Set baudrate 2 4800bps 3 Joy calibrate 3 9600bps 4 19200bps b About Keyboard O Joy calibrate Version 1 00 P k KB ID 008 1 Joy is free then Protocol Factory p F Baudrate 2400 TESS ENTER Dome setup Set dome preset 1 Set dome preset 1 Save preset Preset num 2 Set dom
4. According to the user s need select the suitable PROTOCOL and back to the previous menu 1 Factory 2 Pelco P 3 Pelco D Picture 4 3 2 1 Enter the menu as picture 4 1 1 1 and press the 5 to exit the menu 5 Appendix 5 1 RS485 Bus Basic Knowledge RS485 Bus Basic Character According to RS485 industrial standards RS485 Bus is of half duplex data transmission cables with characteristic impedance as 120 The maximum load capacity is 32 unit loads including main controller and controller equipment Distance of RS485 bus transmission While use the 0 56mm 24AWG twisted cable as the communication the farthest distance it can reach as follow based on the different Baud rate Baud rate Farthest Distance 2400bps 1800M 4800bps 1200M 9600bps 800M 19200bps 600M 14 If user selects thinner cables or installs the dome in an environment with strong electromagnetic interference or connects lots of equipment to the RS485 Bus the maximum transmitting distance will be decreased To increase the maximum transmitting distance do the contrary Connection and termination resistance The RS485 standards require a daisy chain connection between the equipment There must be termination resistance with 120 impedance at both ends of the connection refer to picture 4 1 1 Please refer to picture 4 1 2 for simple connection But D should not exceed 7m 3 4 32 Picture 4 1 1 1 2 3 4
5. key focus for vicinity objects Normally Zoom and focus will be adjusted automaticly by the dome and with the FAR JI NEAR to realize the manual zoom and focus lris Press OPEN key manual Iris accretion whole white picture means max iris Press CLOSE key manual Iris minish whole black picture means min iris 3 6 Dome function operation 3 6 1 Pre set Pre set SET N PRESET Adjust pre set N PRESET N for the number of the pre set 3 6 2 Scan Left borderline SET 1 SCAN Right borderline SET 2 SCAN star 1 SCAN Enter the menu to set when need change the scan speed 3 6 3 Pattern design path setup SET N PATTERN path SET 0 PATTERN Press SET key input the number of design scan 1 4 press PATTERN key enter the path setup state when ending press SET key first then press 0 key then PATTERN key starting the design scan N PATTERN input the design scan number 1 4 press PATTERN key to starting 3 6 4 Cruise starting N TOUR TOUR cruise number first then TOUR key starting the cruise Direct press the TOUR key when the system only have one cruise 3 7 Call Dome main menu 9 5 PRESET Input 95 press PRESET key aimDome menu will display on the monitor 3 8 Matrix control 3 8 1 switch dome orderly The matrix can connect the 16pcs High Speed Dome All the information like the Series NO Data and
6. 32 Picture 4 1 2 eProblems in practical use In some circumstances user adopts a star configuration in practical connection The termination resistors must be connected to the two equipments that are father away from each other such as equipment1 and 15 refer to picture 4 1 3 As the star configuration is not in conformity with the requirements of RS485 standards problems such as signal reflections lower anti interference performance arise when the cables are long in the connection The reliability of control signals are decreased with the phenomena that the dome dose not responds to or just responds at intervals to the controller or dose continuous operation without stop In such circumstances the factory will recommends the usage of Rs485 distributor The distributor can change the star configuration connection to the mode of connection stipulated in the RS485standards The new connection achieves reliable data transmission refer to picture 4 1 4 6 Main Controller 32 Picture 4 1 3 15 1 2 3 Picture 4 1 4 5 2 Keyboard shortcut operation manual Working Mode shortcut Operation object Function Direct Control Mode Press SET for 2 seconds Keyboard IR remote ON OFF Press MENU for 2 Enter the system setting Keyboard seconds Input Dome ID CAM t N CAM High speed dome aa Kap L select object dome Rotate the joystick f Zoom in High
7. correspond NO or the Joy calibrate to move UP and DOWN While you find the item you need move the joystick RIGHT or LEFT to enter the menu 1 Keyboard setup 2 Dome setup 3 Protocol select 4 Exit menu Picture 4 1 1 Save the setting After setting the function you need press ENTER to save the setting After finishing the setting the TFT will display Success Back to Previous menu Press the PREV key to back to the previous menu 4 1 Keyboard parameter setting 4 1 1 Keyboard ID set up 1 Enter the main menu LCD will display picture4 1 1 1 1 Keyboard setup 2 Dome setup 3 Protocol select 4 Exit menu Picture4 1 1 1 2 Press 1 to select the keyboard setting as LCD Picture4 1 1 2 Set KB ID 1 64 Set Baudrate 2400bps Joy calibrate Picture 4 1 1 2 About keyboard 3 Press 1 again will show the picture Picture4 1 1 3 1 Set KB ID 1 64 Picture4 1 1 3 4 Press 1 to select the ID Setting Picture4 1 1 4 1 Set KB ID 1 64 Picture 4 1 1 4 Use the Number key to select the camera ID in the range 1 64 And then press the Enter to save the screen will display Success as picture 4 1 1 5 Success Picture4 1 1 5 If the NO you input is beyond the range1 64 it will display Error as picture 4 1 1 6 Error Picture 4 1 1 6 5 Press PREV or use the shake toward to LEFT to back to previous menu Warning The camera ID default is 1 o
8. is on the keyboard will automatically check the baud rate protocol of the keyboard aim dome and the aim monitor and all the info will be displayed on LCD screen Attention The joystick should be nil when keyboard is initializing 3 2 LCD display screen LCD screen display contents aim dome aim monitor and baud rate etc And at the end of the content will show the current operation order and the states of joystick as follows figure show When operation LCD back light will on and will be off 10s after the operation Camera ID 001 Monitor ID 001 Protocol Pelco d Baud rate 2400bps Figure 3 1 2 3 3 Joystick Controls Dome Functions of the Joystick Dome rotation control and Object dome menu setup When operate the joystick at will to any direction Dome will rotate at the same direction and the direction will be displayed below right corner as G T JL When for menu setup alee the upper menu item aA for the next menu for the sub menu or save the setup for un save or exit Direct proportion between the speed of the Dome and the lean angle of the navigation keys lange lean angle faster rotation speed 3 4 Rigger the aim dome N CAM N for Number input the serial number of the Dome Press CAM key to amend the add of the aim dome 3 5 Dome lens control Zoom Users can control the zoom by rotating the joystick Focus Press FAR key focus for far objects Press NEAR
9. Keyboard Controller Users Manual Contents 1 1 Summary 3 1 1 Notice P OT 3 1 2 Function amp Characteristic 1 3 Technical Data 2 Keyboard connection 2 1 RS485 interfaces 2 2 Connect matrix 2 3 Direct connect with Dome 5 2 4 Keyboard connection in the System 5 3 Keyboard operation instruction 6 3 1 Electrify 6 3 2 LED display screen 6 3 3 Joystick controls dome 7 3 4 Rigger the aim dome 7 3 5 Dome lens control 7 3 6 Set dome func
10. a 4bit power jack follow the surface instruction to find RS485 A B follow the instruction Maybe a different connect way when come from different manufacturer Figure 2 3 1 DC 12V A B RS485 A B Dome Keyboard 2 3 Keyboard connection in the system Indirect control the dome when connect with matrix as figure 2 4 1 contrariwise will control the domes directly Parallel connect the keyboard and dome to the bus of RS 485 all the keyboard can control any dome among them under this way the add of the main keyboard should be 1 and baud rate should be 9600bps as figure 2 3 1 Figure 2 4 1 Keyboard Domel Dome2 Caution 1 the max quantity of master equip and be charged equip controlled by a RS485 bus is so when use the keyboard to control direct the max dome quantity is 3 2 max quantity keyboard in a system is 4 also the 4 keyboards should be different ID Figure 2 4 2 Keyboard 1 Keyboard 2 GED CILE Keyboard 3 Dome 1 Dome 2 Dome 3 Dome 4 CED IC IE ID r ae ae Keyboard 4 Dome 5 Dome 6 Dome 7 Dome 8 wm 3 Keyboard operation instruction LCD screen SS lens control So0002 ogoogo 3D joystick opoo i ooo Number keys Function keys Figure 3 1 1 Attention please because different system have some different special operation ways so should consider the actual reguirement when operation in some special systems 3 1 Electrify When the power
11. e scan 2 Show preset 3 Set dome pattern 3 Clear preset k Press prev to back 4 Set dome tour Set dome scan Set left limit Set right limit Run scan 1 Set left limit 2 Set right limit 7 3 Run scan Press enter sure Press prev to back Press enter sure Press prev to back Success Set dome pattern Set pattern Run pattern 1 pattern num Press 1 to start 2 Set pattern Press 0 to start Success 3 Run pattern Press prev to back Set dome tour Insert preset Run tour 1 Tour num 1 Preset mun 2 Insert preset 2 speed M Success 3 Run tour 3 Dwell Protocol select Matrix Pelco matrix 1 Matrix 1 Pelco matrix E xi d Done 2 DH DVR uccess Dome 1 Factory o 2 Pelco p Success 3 Pelco d 18
12. e the keys and move the joysticks While enter the dome preset menu the keyboard navigate keyboard can directly control the dome and lens control zone also can control the dome s lens 4 2 3 Pattern set up Enter the menu as the picture 4 1 1 1 Press 2 enter the dome setting menu as the picture 4 2 1 1 And then press 3 enter the pattern setting as picture 4 2 3 1 show 1 Pattern num 2 Set pattern 3 Run pattern 12 Picture4 2 3 1 After enter the menu the system need input the pattern information you want you can put in the NO1 4 and Press the ENTER The mouse will skip to the next item automaticly to set the second patter you need If you already have it you can skip it and select the 3 to run the pattern directly Pattern setting After enter the pattern setting menu move the dome do the suitable position and press the 1 to start record the scan track The screen will display Start like the picture4 2 3 2 Press 0 to finish the scan record and the screen will show Success and back to the previous menu Press to start Press 0 to start Press PREV to back Picture 4 2 3 2 Warning Under commonly mode Dome can not control by operate the keys and move the joysticks While enter the dome preset menu the keyboard navigate keyboard can directly control the dome and lens control zone also can control the dome s lens 4 2 4 Tour set up Press 2 ente
13. ens control zone also can control the dome s lens Press 2 enter the Show the preset menu as picture 4 2 1 5 Preset num 1 128 Press PREV to back Picture 4 2 1 5 11 Input the Preset NO that want delete and press the ENTER to call it and the TFT will display Success Use the navigate Key or PREV back to previous menu Press 3 enter the clear the Preset to clear preset information as picture 4 2 1 6 show Preset num 1 128 Press PREV to back Picture 4 2 126 Input the PRESET NO which you want to clear and press the Enter to clear it and it will show Success and back to previous menu 4 2 2 Dome Scan set up Enter the menu 4 1 1 1 Press 2 enter the dome setting menu as the picture 4 2 1 1 Press 2 again to enter the dome scan setting as picture 4 2 2 1 1 Set left limit 2 Set right limit Picture4 2 1 1 3 Run scan Dome scan setting include the Left limit Right Limit and Run scan Press 1 to set the Left limit as picture 4 2 2 2 show Press ENTER sure Press PREV to back Picture 4 2 2 2 While enter the dome limit setting menu move the dome to the suitable position and press Enter to save and will show Success and back to previous menu Select the item 2 to set the Right limit and do the same as the left limit setting Back to the menu and press 3 to operate the Run Scan Warning Under commonly mode Dome can not control by operat
14. equipped with the 3D Joystick and a LCD screen The LCD can display the current operation order the control protocol name the current dome ID the current monitor ID and the state of joysticks Infrared ray emission emission the same data amp content as RS485 1 3 Technical Data Electrical character Input voltage 9V 12V DC Rating Power 0 5W Communicate character Communicate interface RS485 X 1 infrared emission Communicate frequency 2400 4800 9600 19200bps Communicate distance RS485 can reach 1 2Km infrared emission reaches 10m Operational environment Operating temperature 0 C 50 C Relative humidity less than 90 Physical property L W H 168mm 136mm 105mm Weight 0 400 kg 2 Keyboard Connection There is interface on the back of the keyboard which equipped with kinds of communication Interface RS485 and infrared emission which can connect with and control kinds of peripheral equipments 2 1 RS485 interfaces Rs485 interfaces are on the 2bit ribbon cable connection of the keyboard RS485 A B can connect with the dome when the keyboard controls the dome directly RS485 A B can connect with DVR or other keyboards when the keyboard controls the dome by matrix Power RS485 IR remote control 2 2 Direct connect with Dome Keyboard connect the Dome wit RS485 The RS485 interface of the Dome is on the commutator of the Dome Press the metal button in the hanging frame open the commutator will find
15. lay Picture4 1 3 2 Success Picture4 1 3 2 Attention when calibrating the joystick pls make sure the joystick is in the midpoint position 4 1 4 Keyboard information display 10 Enter the keyboard information display menu as LCD Picture 4 1 1 2 Press 2 to check the keyboard information as LCD Picture 4 1 4 1 4 2 Dome set up 4 2 1 Preset set up Enter the main menu as picture 4 1 1 1 and press 2 to enter the dome setting menu as picture 4 2 1 1 This part you can set the follow function Preset Scan Pattern Tour Set dome preset Set dome scan Set dome pattern Set dome tour Picture4 2 1 1 Press 1 enter the dome Preset function setting as picture 4 2 1 2 1 Save preset 2 Show preset 3 Clear preset Picture 4 2 1 2 Item 1 Save preset item 2 Show the preset Item 3 delete the preset Press 1 enter the preset you can input the preset NO as picture 4 2 1 3 show Preset num 1 128 Press PREV to back Picture 4 2 1 3 After enter the preset menu you can use navigate key control the dome directly and input the preset NO to save as the picture 4 2 1 4 show And on the TFT screen will display SUCCESS Success Picture 4 2 1 4 Press Prev back to previous men Warning Under commonly mode Dome can not control by operate the keys and move the joysticks While enter the dome preset menu the keyboard navigate keyboard can directly control the dome and l
16. nly one keyboard in a system it must set to ID as 1 Several keyboards work together at most is 4 keyboards and it must has one keyboard ID is ID1 otherwise all the keyboard can not work And the LCD will show as picture 4 1 2 Keyboard Baud Rate Setting Enter the main menu as the TFT picture 4 1 1 1 show Press 1 will show on the TFT as picture 4 1 1 2 Press 2 select the Baud Rate setting as Picture 4 1 2 1 2 Set Baud rate 2400bps 4800bps 9600bps 19200bps Picture 4 1 2 1 2400bps 4800bps 9600bps 19200bps is available commonly under the IR emission mode baud rate is 2400bps or 4800bps You can select the Baud rate you need and press the ENTER to save If you operate success the screen will show Success Press PREV or move the joystick to LEFT to back to previous menu Warning If connect to the matrix baud rate must be 9600bps Several keyboards work together it must use 9600bps or 19200bps 4 1 3 Joystick calibrate When the joystick at midpoint position pls enter the menu to enter the joystick calibrate Item When calibrating the joystick must be in a natural state Enter the main menu LCD will display picture4 1 1 1 2 Press 1 to select the keyboard setting as LCD Picture4 1 1 2 3 2 Press 3 into joystick calibrate as LCD Picture4 1 3 1 Joystick is free then press Enter Picture4 1 3 1 Press Enter and the joystick calibrate is finished as LCD disp
17. r the dome setting menu as the picture 4 2 1 1 show And then press 4 enter the tour setting as the picture 4 2 4 1 show 1 Tour num 2 Insert preset 3 Run tour Picture 4 2 4 1 After enter the menu you need input the TOUR information the range you can put is 1 6 and press the ENTER confirm Then the mouse will auto skip to the second TOUR setting If first one is ok Users can skip it And it will show the Success and back to the previous menu Select the Item 2 as picture 4 2 4 2 you need input the tour preset and in the second item you need put in the speed information the range is 1 127 In the third item you need input the time how long it need to stop the range is 1 255 After finishing all the step press the ENTER and will display Success and back to previous menu 1 Preset num 2 Speed 3 DWell Picture 4 2 4 2 Press 3 Run the TOUR Attention This model have no the insert tour preset function 13 4 3 Protocol set up Enter the menu as picture 4 1 1 1 Press 3 enter the Protocol setting as picture 4 3 1 1 Matrix DVR 2 Dome r Picture 4 3 1 4 3 1 Pelco Matrix model Press 1 enter the PELCO Matrix model as the picture 4 3 1 1 And then press the ENTER to select the Protocol and back to previous menu 1 Pelco Matrix 2 DH DVR Picture 4 3 1 1 4 3 2 Dome control model Press 2 enter the dome control model as the picture 4 3 2 1
18. speed dome anti clockwise Rotate the joystick Zoom out High speed dome clockwise FAR High speed dome Press FAR far focus NEAR High speed dome Press NEAR near focus CLOSE High speed dome Press CLOSE reduce iris OPEN High speed dome Press OPEN increase Iris Adjust the image to object SET N position Press SET to input the High speed dome PRESET preset and press PRESET J to set the preset Input t ID Preset t N PRESET Highspeeddome P Preset Press Airesera to call the preset SHI 1 LENT Highspeed dome ON OFF water Wiper SHI 21 ENT Highspeed dome ON OFF auxiliary light Adjust the image to object SET 1 SCAN High speed dome position press Set to input 1 then press Scan to set scan left limit Adjust the image to input 2 to object position press Set CSET 2 SCAN High speed dome PAE then press Scan to set scan right limit Input 1 press Scan to run 1 SCAN High speed dome E scan Press Set to input pattern SET N Edis High speed dome number press Pattern to record PATTERN pattern path SET 0 Press SET and inputO Press High speed dome PATTERN PATTERN to save path Input the patt th 1 4 P N PATTERN High speed dome E aR AEN ac PATTERN to start pattern Input the TOUR NO press N TOUR r
19. time will display on the monitor while switch the speed dome camera PREV switch to previous camera Press PREV 2 Sec it will keep switch till the whole 16 high speed dome Press Stop to stop the switching NEXT back forward Press NEXT it will switch to the next camera Press NEXT 2 Sec it will keep back forward switch till the final 16 camera You can use the Stop key to stop the operate 3 8 2 Call matrix main menu SHIFT SET Call the main menu the menu will display on the object monitor How to use the keyboard Setting the matrix Pls refers the matrix operate manual 3 8 3 Confirm after program ENTER after the matrix is programmed press ENTER reflects confirm after program As for the detail program please refer to the matrix operation manual 3 8 4 Change object monitor N MON Input the monitor ID then press MON the image and the menu of the dome that you controlled by keyboard will display in the object monitor 4 Keyboard menu control Keyboard parameter set up Turn on the power and press the MENU the system information will display on the screen like the picture 4 1 1 press again the system information will disappear You can do all the keyboard operation while in the standby condition or the system information display condition Press MENU and hold on 2 sec you will enter the main menu as the picture 4 1 1 1 show All the menu setting need enter the main menu first and use the
20. tion 7 3 6 1 Preset 7 3 6 2 Scan 7 3 6 3 Pattern 7 3 6 4 Cruise 2 2 8 3 7 Call dome main menu 8 3 8 Matrix Control 8 3 8 1 Switch dome in order 8 3 8 2 Call matrix main menu gt 8 3 8 3 Confirm after program 8 3 8 4 Change object monitor 8 4 Keyboard control 8 4 1 Keyboard parameter setup

Download Pdf Manuals

image

Related Search

Related Contents

Install Pyramix V 8 .book  Toshiba 52HM95 Projection Television User Manual  Jumbo LED Wall clock with alarm JUMBO LED  XL6/XL6M/XL6e OCS Models  SoftWall Finishing Systems SW9723352129 Instructions / Assembly  User Manual, HelpDesk OSP - kalmstrom.com Business Solutions  19701 MAXEPOX CEM ESP  Руководство пользователя  Pricing Table Generator v.2.1.0 USER MANUAL  Kenwood KDC-X693 Car Video System User Manual  

Copyright © All rights reserved.
Failed to retrieve file