Home
ARCPOW-06C10/12/15 - Arcus Elektronika
Contents
1. 3 Power W lt 30 1 4 Pulsation mV lt 200 1 5 Battery charge and controll YES 1 6 POWER GOOD signal NO 1 7 ACC GOOD signal YES 2 0 Input parameters 2 1 Voltage V AC V DC 150 250 200 350 2 2 Built in fuse A AC V AC 2 250 2 3 Frequency Hz 0 100 2 4 Efficiency coeficient lt 75 3 0 General parameters 3 1 Insulation resistance MQ gt 100 3 2 Insulation voltage Input Output V AC 21500 3 3 Temperature C 0 50 3 4 Dimensions mm 45 5x120x102 3 5 Weight kg lt 0 350 3 6 Case protection class IP20 3 7 Standards EN55032 2012 EN60950 1 2006 Q TEHNISKIE FAILI TFA XXX_APARATI A VECLAIKI ARCPOW 06CXX_TFA XXX ARCPOW 06C10_TFA 080 19 APR APRAKSTS_UN_TEHNISKIE_PARAMETRI ARCPOW 06C10_User_Manual_11EN docx ARCPOW 06C 10 12 15 Version V1 1 2015 ARCPOW 06C 10 12 15 Table 2 item model ARCPOW 06C12 1 0 Output parameters 1 1 Voltage V DC 14 0 2 1 2 Current A DC lt 2 2 1 3 Power W lt 30 1 4 Pulsation mV lt 200 1 5 Battery charge and controll YES 1 6 POWER GOOD signal NO 1 7 ACC GOOD signal NO 2 0 Input parameters 2 1 Voltage V AC V DC 150 250 200 350 2 2 Built in fuse A AC V AC 2 250 2 3 Frequency Hz 0 100 2 4 Efficiency coeficient lt 75 3 0 General
2. ARCUS F ELEKTRONIKA ARCPOW 06C10 12 15 SWITCHING POWER SUPPLY Technical description and user manual Version V1 1 2015 ARCUS ELEKTRONIKA TIRAINE 2015 Version V1 1 2015 ARCPOW 06C 10 12 15 DOCUMENT VERSIONS CONTROL Version Date Author Changes V1 0 2006 09 08 2006 NOVL Initial version V1 1 2015 01 01 2015 AIVI Translation Copyright for this document is possessed by ARCUS ELEKTRONIKA Ltd Copying this document without acquiring prior written consent from ARCUS ELEKTRONIKA Ltd is prohibited Copyright 2015 ARCUS ELEKTRONIKA Ltd LATVIA Q TEHNISKIE FAIL TFA XXX_APARATI A VECLAIKNARCPOW 06CXX_TFA XXX ARCPOW 06C10_TFA 080 19 APR APRAKSTS_UN_TEHNISKIE_PARAMETRI ARCPOW 06C10_User_Manual_11EN docx Version V1 1 2015 Switching power supply ARCPOW 06C10 12 15 hereinafter referred to as SPS with the power of 30W is provided for charging 12V lead acid battery controlling the discharge process as well as protection against overload incorrect connection and against excessive discharge of battery SPS has power good signal output The SPS may be integrated into industrial or ARCPOW 06C10 12 15 SWITCHING POWER SUPPLY FOR BATTERY CHARGING household appliances 1 TECHNICAL DATA Table 1 item model ARCPOW 06C10 1 0 Output parameters 1 1 Voltage V DC 14 0 2 1 2 Current A DC lt 2 2 1
3. C 12V DC GND Table 4 Connector X1 pin designation name 1 PE Protection 2 250VAC N INPUT for DC voltage polarity is not important 3 250VAC L INPUT for DC voltage polarity is not important Table 5 Connector X2 pin designation name 1 14 VDC OUTPUT 2 2A DC 2 GND OUTPUT 2 2A DC 3 POWER GOOD POWER GOOD 4 ACC GOOD Battery ACC GOOD 12V DC 1mA DC Table 6 Connector X3 pin designation name 1 14 VDC OUTPUT 2 2A DC 2 GND OUTPUT 2 2A DC Table 7 Connector X4 pin designation name 1 12 VDC INPUT battery 12V 7 2Ah 2 12 VDC GND INPUT battery 12V 7 2Ah Q TEHNISKIE FAILI TFA XXX_APARATI A VECLAIKI ARCPOW 06CXX_TFA XXX ARCPOW 06C10_TFA 080 19 APR APRAKSTS_UN_TEHNISKIE_PARAMETRI ARCPOW 06C10_User_Manual_11EN docx ARCPOW 06C 10 12 15 Version V1 1 2015 4 ASSEMBLING SPS is designed to fix on rail DIN 35 120mm Rail DIN 35 Fig 3 Dimensions Leave at least 25mm free space arround the SPS for cooling Q TEHNISKIE FAILI TFA XXX_APARATI A VECLAIKI ARCPOW 06CXX_TFA XXX ARCPOW 06C10_TFA 080 19 APR APRAKSTS_UN_TEHNISKIE_PARAMETRI ARCPOW 06C10_User_Manual_11EN docx Version V1 1 2015 ARCPOW 06C 10 12 15 5 GARANTIJAS NOTEIKUMI Warranty repairs of the SPS can be carried out within 24 months after selling only in case if the defect has occurred due
4. parameters 3 1 Insulation resistance MQ gt 100 3 2 Insulation voltage Input Output V AC 21500 3 3 Temperature C 0 50 3 4 Dimensions mm 45 5x120x102 3 5 Weight kg lt 0 350 3 6 Case protection class IP20 3 7 Standards EN55032 2012 EN60950 1 2006 Table 3 item model ARCPOW 06C15 1 0 Output parameters 1 1 Voltage V DC 24 0 5 1 2 Current A DC lt 1 5 1 3 Power W lt 36 1 4 Pulsation mV lt 200 1 5 Battery charge and controll YES 1 6 POWER GOOD signal NO 1 7 ACC GOOD signal YES 2 0 Input parameters 2 1 Voltage V AC V DC 150 250 200 350 2 2 Built in fuse A AC V AC 2 250 2 3 Frequency Hz 0 100 2 4 Efficiency coeficient lt 75 3 0 General parameters 3 1 Insulation resistance MQ gt 100 3 2 Insulation voltage Input Output V AC 21500 3 3 Temperature C 0 50 3 4 Dimensions mm 45 5x120x102 3 5 Weight kg lt 0 350 3 6 Case protection class IP20 3 7 Standards EN55032 2012 EN60950 1 2006 Q TEHNISKIE FAILI TFA XXX_APARATI A VECLAIKI ARCPOW 06CXX_TFA XXX ARCPOW 06C10_TFA 080 19 APR APRAKSTS_UN_TEHNISKIE_PARAMETRI ARCPOW 06C10_User_Manual_11EN docx Version V1 1 2015 ARCPOW 06C 10 12 15 2 STRUCTURE AND OPERATION Switching power supply ARCPOW 06C10 12 15 contains an electromagnetic interference filter a mains voltage rectifier a swi
5. tching regulator a high frequency impulse transformer a secondary voltage rectifier an electronic switch for battery connection a load relay and a controller of charge discharge process The SPS converts rectified mains voltage into impulses of an alterable width with 100 kHz frequency which is converted into secondary direct voltage by the help of transformer and rectifier Controller measures secondary voltage and current compares the acquired measurements to voltage reference and control the switching regulator via optron The SPS performs battery and load connection control Charging takes place only if the battery is connected correctly and it is not damaged O 230 V AC Rectifier Capacitor 14V DC 2 2A bridge citor Shunt Oo Transformer Regulator Optron Failure amplifier c ACC GOOG Relay Battery Fig 1 Structure drawing Q TEHNISKIE FAIL TFA XXX_APARATI A VECLAIKN ARCPOW 06CXX_TFA 5 XXX ARCPOW 06C10_TFA 080 19 APR APRAKSTS_UN_TEHNISKIE_PARAMETRI ARCPOW 06C10_User_Manual_11EN docx Version V1 1 2015 ARCPOW 06C 10 12 15 3 CONNECTORS AND SIGNALS ARCPOW 06C10 12 15 150 250V AC 200 350V DC 14V DC 2 2A DC input 230V AC N 230V AC L Fig 2 Connectors output 14V DC GND output 14V DC GND POWER GOOD ACC GOOD input 12V D
6. to manufacturer its work or materials used This warranty is not valid in case damages or operation failure has occurred due to user s non observance of terms and conditions given in service instruction improper storage or transportation Warranty and post warranty repairs shall be performed by manufacturer ARCUS ELEKTRONIKA Ltd TIRAINES IELA 1 TIRAINE M RUPES NOV LV 2167 LATVIA phone 371 67675752 fax 371 67675387 e mail info arcuselektronika com web page http www arcuselektronika com Q TEHNISKIE FAILITFA XXX_APARATI A VECLAIKI ARCPOW 06CXX_TFA 8 XXX ARCPOW 06C10_TFA 080 19 APR APRAKSTS_UN_TEHNISKIE_PARAMETRI ARCPOW 06C10_User_Manual_11EN docx
Download Pdf Manuals
Related Search
Related Contents
Dataram DRSM5000/32GB memory module SmartPool Inc Robo-Kleen User's Manual Integral IN1T1GNQKBXK2 memory module Partie 3 : Grandeur de mesure H2O2 et acide péracétique NetCam XL Brochure - StarDot Technologies Portable Battery Pack FRS1000 Installation Manual M1 1-8-02 OT Tracking User Manual - NYPD Manual de usuario Galaxy DX 2547 Copyright © All rights reserved.