Home

AM-60 Compact Digital Multimeter Product Manual

image

Contents

1. AMPROBE AM 60 Compact DMM with NCV amp Logic Test Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso AMPROBE AM 60 Compact DMM with NCV amp Logic Test Users Manual 2009 Amprobe Test Tools All rights reserved Printed in China Limited Warranty and Limitation of Liability Your Amprobe product will be free from defects in material and workmanship for 1 year from the date of purchase This warranty does not cover fuses disposable batteries or damage from accident neglect misuse alteration contamination or abnormal conditions of operation or handling Resellers are not authorized to extend any other warranty on Amprobe s behalf To obtain service during the warranty period return the product with proof of purchase to an authorized Amprobe Test Tools Service Center or to an Amprobe dealer or distributor See Repair Section for details THIS WARRANTY IS YOUR ONLY REMEDY ALL OTHER WARRANTIES WHETHER EXPRESS IMPLIED OR STAUTORY INCLUDING IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY ARE HEREBY DISCLAIMED MANUFACTURER SHALL NOT BE LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES ARISING FROM ANY CAUSE OR THEORY Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages this limitation of liability may not apply to you Repair All test too
2. Fax 425 446 6390 Fax 905 890 6866 Non Warranty Repairs and Replacement Europe European non warranty units can be replaced by your Amprobe Test Tools distributor for a nominal charge Please check the Where to Buy section on www amprobe com for a list of distributors near you Amprobe Test Tools Europe In den Engematten 14 79286 Glottertal Germany tel 49 0 7684 8009 0 Correspondence only no repair or replacement available from this address European customers please contact your distributor AM 60 Compact DMM with NCV amp Logic Test am co 3 3 4 digits 2000 counts LCD display Push buttons for special functions 8 features Selector to turn the Power On or Off and select Function Input Jack current function O Common Ground reference Input Jack for all functions 6 Input Jack for all functions except current function AM 60 Compact DMM with NCV amp Logic Test CONTENTS KAA AAA AA EENEG 2 UNPACKING AND INSPECTION EE 3 INTRODUCTION BEE A OPERATION ia 4 SPECIFICATION MEM 8 12 TROUBLE SHOOTING Fuse Replacement LIA 13 Battery Replacement mama AGANG AA AG 13 SYMBOLS A Warning Dangerous Voltage Risk of electric shock A Caution Refer to the user s manual before using this Meter Double Insulation or Rei
3. the red LED lights up to verify the instrument is operational The Volt sense button must be held down to detect the presence of voltage without use of the leads If a voltage of 50V to 600V 50 to 500 2 is detected near the top of meter a continuous tone sounds and the red LED near the top of meter Illuminates SPECIFICATIONS General Specifications Display Polarity Indication Overrange Indication Batteries Life Low Batteries Indication Auto Power Off Operating Ambient Storage Temperature Temperature Coefficient Measure Altitude Safety WO A Pollution degree Power Requirements Dimensions W x Hx D Weight Accessories Electrical Specifications 2000 counts Automatic positive implied negative indicated OL or OL Alkaline 250 hours is displayed when the batteries voltage drops below operating voltage Approx 10 minutes Non condensing 50 F 51 8 F 86 F 380 87 8 F 104 F 57595 105 8 F 122 F 4596 4 F to 140 F 0 to 80 R H when battery removed from Meter 0 15 x Spec Accy F lt 64 4 F or gt 82 4 F Samples 2 times per second nominal 6561 7 ft 2000m Complies with EN61010 1 UL61010 1 IEC 61010 1 CAT III 600V CAT II 1000V CAT III 500V 2 1 5V x 2 IEC LR03 AM4 or AAA size 74mm 2 9 x 156mm 6 1 x 44mm 1 7 320g 0 7116 including battery Battery installed Tes
4. and take appropriate precautions to avoid misleading results when making measurements in the presence of electronic interference MAINTENACE If there appears to be a malfunction during the operation of the meter the following steps should be performed in order to isolate the cause of the problem 1 Check the battery Replace the battery immediately when the EH symbol appears on the LCD 2 Review the operating instructions for possible mistakes in operating procedure Except for the replacement of the battery repair of the meter should be performed only by a Factory Authorized Service Center or by other qualified instrument service personnel The front panel and case can be cleaned with a mild solution of detergent and water Apply sparingly with a soft cloth and allow to dry completely before using Do not use aromatic hydrocarbons or chlorinated solvents for cleaning If the meter is not to be used for periods of longer than 60 days remove the batteries and store them separately Do not attempt to repair this Meter It contains no user serviceable parts Repair or servicing should only be performed by qualified personnel TROUBLE SHOOTING If the instrument fails to operate check batteries and test leads etc and replace as necessary Double check operating procedure as described in this user s manual If the instrument voltage resistance input terminal has subjected to high voltage transient caused by lightning
5. or switching surge to the system by accident or abnormal conditions of operation the series fusible resistors will be blown off become high impedance like fuses to protect the user and the instrument Most measuring functions through this terminal will then be open circuit The series fusible resistors and the spark gaps should then be replaced by qualified technician Refer to the LIMITED WARRANTY section for obtaining warranty or repairing service 12 Fuse Replacement Refer to the following figure to replace fuse CAUTION Use only a fuse with the amperage interrupt voltage and speed rating specified Fuse rating 10A 500V Battery Replacement Refer to the following figure to replace the batteries 13 Visit www Amprobe com for e Catalog e Application notes e Product specifications e User manuals e Please Recycle
6. instrument that combines several measurement functions in one unit AM 60 multimeter is portable hand held devices useful for basic fault finding and field service work or a bench instrument which can measure to a very high degree of accuracy They can be used to troubleshoot electrical problems in a wide array of industrial and household devices such as batteries motor controls appliances power supplies and wiring systems OPERATION Measuring AC DC Voltage And dit a 4986 1985 Testing for Continuity and Diode Bad Diode Black Red Black Good Diode Resistance and Capacitance Note To improve the measurement accuracy of small value capacitor record the reading with the test leads open then substract the residual capacitance of the Meter and leads from measurement Cunknown CMEASUREMENT CRESIDUAL MIN MAX Record dite 1995 0603 osoo wE Press mi gt pa 77 Press gt 1sec D Press gt 1sec wg Measuring DC AC Current o Display Hold Press Press 3 Press imp Press gt 1sec Press gt 1sec wu Press gt 1sec Auto Power Off Battery Saver Disable Auto Power Off Ww N Press Volt sense switch will be activated on any function or at OFF status Test leads are not used for the Volt sense test Press the Volt sense button The display goes black a tone sounds and
7. ls returned for warranty or non warranty repair or for calibration should be accompanied by the following your name company s name address telephone number and proof of purchase Additionally please include a brief description of the problem or the service requested and include the test leads with the meter Non warranty repair or replacement charges should be remitted in the form of a check a money order credit card with expiration date or a purchase order made payable to Amprobe Test Tools In Warranty Repairs and Replacement All Countries Please read the warranty statement and check your battery before requesting repair During the warranty period any defective test tool can be returned to your Amprobe Test Tools distributor for an exchange for the same or like product Please check the Where to Buy section on www amprobe com for a list of distributors near you Additionally in the United States and Canada In Warranty repair and replacement units can also be sent to a Amprobe Test Tools Service Center see next page for address Non Warranty Repairs and Replacement US and Canada Non warranty repairs in the United States and Canada should be sent to a Amprobe Test Tools Service Center Call Amprobe Test Tools or inquire at your point of purchase for current repair and replacement rates In USA In Canada Amprobe Test Tools Amprobe Test Tools Everett WA 98203 Mississauga ON 142 1X9 Tel 888 993 5853 Tel 905 890 7600
8. min 10min 5A Continually N A Resistance Range Accuracy Voltage Burden 200 0 200 0K0 0 7 3 dgt 2 000 0 x 1 096 3 dgt 2V max 20 00M0 1 5 3 dgt Open circuit Voltage lt 100 dgt rolling 1 3V approx The minimum LCD reading is 1400 count in Auto Ranging Mode Diode Check and Continuity Resolution Accuracy 10 mV 1 5 5 dgt For 0 4V 0 8V Max Test Current 1 5mA Max Open Circuit Voltage 2V Overload Protection 600V rms 10 Frequency Range Sensitivity Accuracy gt 1 5 Vac rms 2000Hz 200 0KHz lt 5 Vac rms Frequengy 0 01 1digit 2 000MHz 20 00MHz SE lt 5 Vac rms Overload Protection 600V rms Minimum pulse width gt 25 ns Duty cycle limits gt 30 and lt 70 Capacitance Overload Range Accuracy Protection 2 000nF 200 0uF 1 9 8 dgt 600V rms 2 000mF lt 10 dgt of reading rolling C 61326 1 This product complies with requirements of the following European Community Directives 89 336 EEC Electromagnetic Compatibility and 73 23 EEC Low Voltage as amended by 93 68 EEC CE Marking However electrical noise or intense electromagnetic fields in the vicinity of the equipment may disturb the measurement circuit Measuring instruments will also respond to unwanted signals that may be present within the measurement circuit Users should exercise care
9. nforced insulation Alternating Current AC Direct Current DC Low battery indicator a Fuse L Ground maximum permitted voltage between terminal and T ground A Please remove all the test leads before preforming maintenance cleaning battery replacement fuse replacement etc C Complies with European Directives Conforms to relevant Australian standards Q Do not dispose of this pruduct as unsorted municipal waste Contact a qualified recycler for disposal Sa AWarnings e Do not operate this meter in explosive gas material combustible gas material steam or filled with dust e When using test leads or probes keep your fingers behind the finger guards e Remove test lead from Meter before opening the battery door or Meter case e Use the Meter only as specified in this manual or the protection by the Meter might be impaired e Always use proper terminals switch position and range for measurements e Never attempt a voltage measurement with the test lead inserted into the A input terminal e Verify the Meter s operation by measuring a known voltage If in doubt have the Meter serviced Do not apply more than the rated voltage as marked on Meter between terminals or between any terminal and earth ground Do not attempt a current measurement when the open voltage is above the fuse protection rating Suspected open circuit voltage can be checked with
10. t leads and user manual Accuracy is reading number of digits at 23 x 5 lt 80 RH DC AC Volts Range AC Accuracy 200 0 Unspecified 2 000V 1 5 5dgt 50Hz 300Hz 20 00V 200 0V 750V AC 1000V DC 1 5 5dgt 50Hz 500Hz DC Accuracy Over voltage protection Input Impedance CMRR NMRR Vac Voc AC Conversion 0 5 2dgt 1000V DC or 750 V ACrms A less than 100pF Common Mode Rejection Ratio Normal Mode Rejection Ratio CMRR gt 60GB at DC 50Hz 60Hz CMRR gt 100dB at DC 50Hz 60Hz NMRR gt 50GB at DC 50Hz 60Hz Average sensing rms indication AC conversions are ac coupled true rms responding calibrated to the sine wave input The minimum LCD reading is 1400 count in Auto Ranging Mode Crest Factor C F Peak Rms 1 5 addition error for C F from 1 4 to 3 3 addition error for C F from 3 to 4 DC AC Current Voltage Range DC Accuracy AC Accuracy Burden 2 000A x 1 596 5 dgt 1 0 3 dgt 50Hz 500Hz 2V max 10 00A Overload Protection A input 10A 500V fast blow fuse AC Conversion Type Conversion type and additional specification are same as DC AC Voltage Ampere Testing Duty Ratio Table Ampere Testing Time Rest Time 10A 1min 10min 9A 2min 10min 8A 3min 10min 7A 4min 10min 6A 5
11. voltage function Only replace the blown fuse with the proper rating as specified in this manual Use caution with voltages above 30 Vac rms 42 Vac peak or 60 Vdc These voltages pose a shock hazard To avoid false readings that can lead to electric shock and injury replace battery as soon as low battery indicator appears Disconnect circuit power and discharge all high voltage capacitors before testing resistance continuity diodes or capacitance Do not use Meter around explosive gas or vapor To reduce the risk of fire or electric shock do not expose this product to rain or moisture Disconnect the test leads from the test points before changing the position of the function rotary switch Never connect a source of voltage with the function rotary switch in Q gt A At Hz position Do not expose Meter to extremes in temperature or high humidity Never set the meter in A function to measure the voltage of a power supply circuit in equipment that could result in damage the meter and the equipment under test UNPACKING AND INSPECTION Your shipping carton should include 1 2 2 1 If any AM 60 Meter Test Leads Battery SIZE AAA 1 5V User s Manual of the items are damaged or missing return the complete package to the place of purchase for an exchange INTRODUCTION Multimeter AM 60 can be used to measure voltage resistance capacitance frequency current It is an electronic measuring

Download Pdf Manuals