MAG HVLP AUTOMATIC AIRSPRAY GUN ii 2 G X

image

Contents

1. solenoid valve should be kept as short as possible for quick triggering 4 All the air used in the gun should be dirt and moisture free This is accomplished by using an oil and water extractor 5 Shut off all the fluid and air lines to the gun if the gun is to stand idle for any length of time This is to prevent build up or accumulation of minute leaks in the system from turning the gun on 6 The distance between gun and surface should be 6 to 12 inches depending on material and the atomizing pressure The material deposited should always be even and wet Lap each stroke over the proceeding stroke to obtain a uniform finish 7 CONTROLLING THE MATERIAL FLOW If necessary fluid can also be adjusted by adjusting the amount of needle travel This is done by loosening lock nut 2 and adjusting control knob 1 until the correct needle travel is achieved 8 ADJUSTING THE SPRAY PATTERN The width of the spray pattern is controlled by the side port control assembly 31 Turning this control clockwise until it is closed will give a round spray turning it counterclockwise will widen the spray into a fan shape The fan shape can be turned anywhere through 360 by positioning the air cap 20 relative to the gun To effect this loosen retainer ring position nozzle then re tighten retainer ring BiIrikS MAG HVLP AUTOMATIC SPRAY GUN MAINTENANCE TROUBLESHOOTING Disassemble spray gun and remove all o rings before immersing gun i
2. 33 54 4945 Tube Connector 4 54 5357 Needle Return Spring ccscceeeee 1 1 8 NPT M x 1 4 Tubing 5 20 6783 Special O Ring 029 white 1 34 20 6131 1 4 NPT Plug HEX Skt Hd S S 05 6 e Piston Impact RING sscserecsseeeees 1 35 57 13 1 1 4 NPS x 1 4 NPT DM Nipple 7 54 5332 Piston Return Spring cseeeeeeees 1 36 20 1359 1 Screw Sq Hd 5 16 18 x 5 8 8 Needle Assembly ccccsscseceeceeees 1 37 Screw 10 32 x 1 4 Flathead 9 54 3603 Needle Cap scenes 1 Allen Hd PHO siiis 10 54 3604 Needle LOCKNUt ccccccceseceseseseeees 1 38 102 2839 Side Port PLUG cxcicisaincscscscorasccracetecccene 11 54 5355 Piston ASSeMbly scccccseseeeseseseeees 1 39 54 1835 100 Mesh Filter Assembly 1 12 54 5318 Atomizing Air Valve o n 2 higher pressure 13 20 6785ex Special O Ring 2 004 white 2 40 54 5340 4 Filter Retaining Assembly 1 14 20 6786 Special O Ring 2 003 white 2 41 Allen Socket HD 8 32 x 1 3 4 Lg 2 15 Piston BOY scrcctdisecsstsvoietereduicienactestecens 1 20 3586 Allen Wrench ccccceeeeeeseeeeees O 16 20 6783 Special O Ring 2 029 white 1 20 6751 3 8 Socket Deep Well 17 20 6784 Special O Ring 2 015 white 1 18 54 5350 Low Pressure Fluid Cartridge Assy 1 e Available as part of Rebuil
3. STANDARD DELRIN TIP 90P 92P 94P 100P 4006 1200 0 0 055 140 AB STANDARD DELRIN TIP 90P 92P 94P 100P 4006 1300 0 0 070 178 97 AB STANDARD DELRINTIP 90P 92P 94P 100P 4006 1400 0 0 030 076 90 AB STANDARD DELRINTIP 90P 92P 94P 100P 4006 1500 0 0 020 051 88 90PF STANDARD DELRIN TIP 90P 92P 94P 100P 4006 1600 0 0 045 114 92 AB STANDARD DELRIN TIP 90R 92P 94P 100P 4006 49000 0 025 osa soa 90PF STANDARD DELRIN TIP 90P 92R 94P 100P _ 4008 1100 0 0040 102 9 ABSS STANDARD STAINLESS 90P 92P 94P 100P 4008 1200 0 0 055 140 9 ABSS 4008 1400 0 0 030 076 90 90SF STANDARD STAINLESS 90P 92P 94P 100P 4008 1500 0 0020 051 89 90sF 4008 4900 0 0 025 064 83A 90SF STANDARD STAINLESS 90P 92P 94P 100P Air caps are selected based on fluid flow rates and fluid viscosities Consult Binks Tech Support team for further details FLUID NOZZLE ORIFICE INCHES NOZZLE ORIFICE APPROX MM FLUID NEEDLE DESIGNATION DESIGNATION NUMBER LESS FLUID NOZZLE DESIGNATION APPLICABLE NEEDLE TYPE AIR NOZZLES MANIFOLD 4007 0000 0 NOT SUPPLIED NOT SUPPLIED NOT SUPPLIED NOT SUPPLIED NOT SUPPLIED NOT SUPPLIED NOTE Order fluid nozzles needles and air cap separately Standard Needles e 90PF Feathering DELRIN e AB Standard DELRIN Optional Needles e 90SF F
4. BINK MAG HVLP AUTOMATIC AIRSPRAY GUN CE EDII2GX We AVAA N 4 0 Le Q 7 S k Se p we The following instructions provide the necessary information for the proper operation and preventive maintenance of the Binks MAG HVLP Manifold Mounted Airspray Gun Please read and understand all information in this document in order to get the maximum performance from your new MAG HVLP airspray gun The automatic MAG HVLP gun is a conventional style airspray gun with special nozzle and modifications that allow it to operate at high transfer efficiencies in compliance with the California South Coast Air Quality Management District regulations as a high volume low pressure airspray gun High pressure low volume airflow is converted to high volume low pressure within the gun body Special air and fluid nozzle enable the gun to atomize fluid at low air pressure and velocities creating the soft spray effect for high transfer efficiencies A CAUTION Before removing any components from spray gun shut off air and material pressure NOTE IMPORTANT REGULATORY NOTE regarding the use of this product appears on page 6 If you have any questions or do not understand the information presented call your nearest service representative SPECIFICATIONS Max Air Pressure 100 psi 6 8 bar For HVLP compliance See page 5 Max Fluid Pressure 120 psi 8 3 bar Min Max Cylinder 50 psi 3 4 ba
5. LOW ATOMIZING INLET AIR FLOW ATOMIZING INLET AIR FLOW ATOMIZING PSI SCFM PSI PSI SCFM PSI PSI SCFM PSI 6 0 4 5 3 0 14 0 7 0 3 0 3 0 3 2 2 0 8 5 6 0 5 0 21 0 9 0 5 0 6 1 4 8 4 0 11 0 6 8 7 0 27 0 11 0 7 0 9 0 6 0 6 0 13 5 7 5 9 0 30 0 12 0 9 0 11 6 6 9 8 0 15 0 8 0 10 0 33 0 13 0 10 0 14 3 8 0 10 0 AIR NOZZLE TEST GAUGE ASSEMBLY Part No Description Part No Description 54 3902 92P Nozzle 54 4345 90P Nozzle 54 3935 95P Nozzle 54 4356 93P Nozzle 54 4066 94P Nozzle 54 5650 100P Nozzle AE FLUID NOZZLES STANDARD NOZZLES Part Fluid Orfice Size Orfice Size Applicable Material Number Nozzle No inches mm Air Nozzle Compatiable Fluid Needle Ultra Light 458900 89 002 5 Reduced Flow 0 6 SOP 92P 933P 54 5360 90PF Feathering Delrin Tip Very Light JAR SOP 54 5365 90SF Feathering S S Tip Reduced Flow Light less than 15 to 20 45 9000 a 0 030 0 8 45 9100 0 040 100P seconds in ZAHN 2 Cup 45 9200 0 046 90P 92P 93P 54 5370 AB Delrin Tip 54 5375 ABSS e g stains varnishes 45 9400 O 4 0 055 94P 95P Stainless Steel Tip thin lacquers automotive refinishing materials 45 9700 0 070 100P BINK IMPORTANT REGULATORY NOTE Some regulatory agencies prohibit the operation of HVLP spray guns above 10 PSI nozzle atomizing pressure Users subject to this type of regulation should not exceed 10 PSI It is recommended that the air nozzle test gauge assembly be used to confirm actual nozzle oper
6. ance information result in severe personal injury death or substantial property damage TOXIC FLUID HAZARD e Know the specific hazards of the fluid you are using This information is on the MSDS for the material being used Read all fluid manufacturer warnings e Store hazardous fluids in approved containers only Dispose of all hazardous fluids in accordance with all state local and national guidelines e Wear the appropriate protective clothing gloves eyewear and respirator Equipment misuse can cause the equipment to fail malfunction or start unexpectedly and result in serious injury FIRE AND EXPLOSION HAZARD e Ground the equipment and object being sprayed e Provide fresh air ventilation to avoid the build up of flammable fumes from the material being sprayed or from solvent e Extinguish all open flames or pilot lights in spray area e Electrically disconnect all equipment in the spray area e Keep the spray area free from all debris including solvent rags e If there is any static sparking while using the equipment STOP SPRAYING IMMEDIATELY Identify and correct the problem EQUIPMENT MISUSE HAZARD e This equipment is for professional use only e Read and understand all instructional manuals tags and labels before operating equipment e Use the equipment only for its intended purpose If you are unsure about its purpose call your local Binks distributor e Do not alter or modify th
7. ation pressure It may also be a requirement of some regulatory agencies that user have this gauge nozzle available on site to verify that the gun is being operated within the limits of applicable rules MAG HVLP AUTOMATIC GUN SPECIFICATIONS ML 1 8 NPT F CYL INDE AIR INLET 8 32 X 3 16 DEEP TYPICAL 8 PLACES THREADED SET SCREW FOR ROD MOUNT SIDE PORT AIR FAN ADJUSTMENT PLATE MOUNTING SPECIFICATIONS AoW Z INE 1 4 NPT F A CF R INLET AIR INLET 7 185 E 1 659 T o S DG __ __ _ AMINA RS J 2 a OT Z Z 1 ZA NN PISTON VENT AND FLUID BY PASS WEEP PORT oc al 1 4 NPT F FLUID 1 2 DIA HOLE E 1 477 INLET TYPICAL FOR ROD MOUNT BOTH SIDES MAG HVLP AUTOMATIC HOSE HOOK UPS Hose Hook Up with Atomizing Fan Air Hose Hook Up with Atomizing Fan Air COMBINED SEPARATED FLUID RETURN ATOMIZING AIR REGULATOR ATOMIZING AIR REGULATOR CYLINDER AIR SOLENOID 3 WAY CYLINDER AIR SOLENOID 3 WAY I FILTER FILTER lt FLUID SUPPLY FLUID SUPPLY PANAIR REGULATOR BINK ITEM PART ITEM PART NO NO DESCRIPTION QTY NO NO DESCRIPTION QTY 1 54 3731 Material Valve Control Screw 1 31 54 37204 Side Port Control Assembly 1 2 54 3732 Control Screw Locknut cee 1 32 54 5358 Air Fluid Inlet Junction Assy 1 3 54 5356 End Cap HVLP Automatic 1
8. d Kit 54 5307 19 54 3531 Retaining Ring T 1 May also be purchased separately 20 Air Nozzle widddeueqawddeshetenndatawevewdenweneenaden 1 Available as part of 54 5333 K6 _ ie Nozzle AE E EEES 1 Item Nos 30 31 amp 40 are part of 32 Manifold etaining RINg SCreW sses 4 and are shipped loose 23 54 5353 MAG HVLP Fluid Manifold Assy 1 l 24 20 4615 5 O Ring 2 008 PTFE 5 Pack 5 Items shipped loose 25 54 5324 Automatic Piston Housing 1 Available as Dual Port Conversion Kit 54 5308 26 20 3467 O Ring 2 010 PTFE c ccceeeeeees 2 Optional 27 54 5326 Fluid Manifold Port Plug 0 2 Tools provided wien pry aur 28 54 3918 Gun Wrench not shown 06 1 a 30 20 5921 A O Ring 2 017 PTFE ceccesccccccsssssseeeeee 1 ple lela aa LALA aA ARA MAG HVLP AUTOMATIC SPRAY GUN MANIFOLD INCLUDES 30 34 35 36 37 38 40 PARTS LIST When ordering please specify Part No Not all part numbers are available for purchasing 20 6571 SOCKET WRENCH 3 8 MAG HVLP AUTOMATIC SPRAY GUN HOW TO ORDER GUN COMBINATIONS AVAILABLE AS STANDARD WITHOUT AIR CAPS ORDER AIR NOZZLES SEPARATELY SUPPLIED WITH GUN FLUID NEEDLE DESIGNATION FLUID NOZZLE ORIFICE APPROX MM FLUID NOZZLE ORIFICE INCHES DESIGNATION NUMBER WITH MANIFOLD FLUID NOZZLE DESIGNATION APPLICABLE NEEDLE TYPE AIR NOZZLES 4006 1100 0 0 040
9. e in Zones 1 and 2 EC Declaration of Conformity Manuf By CE amp Finishing Brands 195 Internationale Blvd Glendale Heights IL 60139 Type Series Model MAG HVLP 4006 4007 4008 4009 Manifold Mounted Automatic Spray Guns The equipment to which this document relates is in conformance with the following standards or other normative references EN ISO 12100 1 amp 2 2003 and BS EN 1953 1999 and thereby conform to the protection requirements of Council Directive 98 37 EC relating to Machinery Safety Directive and EN 13463 1 2001 Council Directive 94 9 EC relating to Equipment and Protective Systems for use in Potentially Explosive Atmospheres protection level Il 2 G X Approved By Date _ April 17 2006_ Chuck McCulloch Finishing Brands Finishing Brands reserves the right to modify equipment specification without prior notice 2 BINK MAG HVLP AUTOMATIC SPRAY GUN SET UP INSTRUCTIONS SPRAY INSTRUCTIONS TO CHANGE FROM COMBINED FAN AND AIR TO SEPARATE FAN AND ATOMIZING AIR 1 Remove item 31 side port control by turning counter clockwise with a 9 16 wrench 2 Install item 37 allen head set screw into thread at the bottom of tapered cavity of where the side port was 3 Install item 38 side port plug into the upper part of the threaded cavity of where the side port was 4 Remove item 34 1 4 NPT plug from the fan air port and replace it with item 35 D M nipple When fan and at
10. eathering S S e ABSS Standard S S CLEANING KIT ACCESSORIES PART NO DESCRIPTION 54 380 Gun Mounting Bracket PART NO DESCRIPTION 54 1835 100 Mesh Filter 54 4994 Cleaning Kit includes one standard stiff nylon pipe 54 1836 60 Mesh Filter cleaning brush full size nylon brush tip cleaner and 54 5340 Filter Retainer Assembly Binks Gunners Mate Lubricant 54 3918 Cun Wrench 6 428 Gun Lube 2 oz bottle REPAIR KIT 6 429 Gun Lube 20 bottles ref only 54 5307 REBUILD KIT CONSISTS OF 83 2484 Fluid Inlet Stainless Nipple 1 4 NPT x 3 8 NPS A o ne 1 4 ID X 3 8 OD 54 5303 Standard Performance Seal Kit AEA 30 4615 O RING 54 5307 High Performance Seal Kit 2 EA 20 6786 O RING 54 5308 Dual Port Conversion Kit 1 EA 20 5921 O RING 2 EA 20 6785 O RING 2 EA 20 6783 O RING 1 EA 54 5331 PISTON IMPACT RINGS WARRANTY This product is covered by Binks 1 Year Limited Warranty Binks Sales and Service www binks com Toll Free Customer Service and Technical Support 800 992 4657 Toll Free Fax 888 246 5732 U S A Canada Customer Service BiliKkS 195 Internationale Blvd Glendale Heights IL 60139 630 237 5000 77 2803R 11 Revisions Trademark updates P8 Updated contact information 2 13 2013 Binks All rights reserved Printed in U S A
11. ed holes in the back of the piston Pull the two threaded screws and remove the piston 4 Replace o rings 13 14 16 and 17 using standard piston o ring repair kit 54 5303 or high performance piston o ring repair kit 54 5307 5 Apply MG75 PTFE based lubricant provided in the o ring repair kits to O rings and reassemble in reverse order SERVICING REPLACING OPTIONAL FILTER Service symptoms e Fluid tip clogging or restriction in fluid flow 1 Using a 3 4 inch wrench turn filter retainer 40 counterclockwise and remove 2 Place a standard screwdriver inside the cavity where the filter 39 is housed and dislodge it by lifting up with the screwdriver Remove filter and clean or replace as required Most of the time you can dislodge the filter using your finger 3 Reassemble in reverse order O ring 28 does not require replacement when servicing filter Replace o ring 28 if a leak develops around filter retainer 27 REMOVING REPLACING GUN ASSEMBLY MODULE ONLY FROM INLET MANIFOLD ASSEMBLY 1 Using a 9 64 Allen wrench turn retaining cap screw 22 counterclockwise typical 4 places and remove gun sub module NOTE O rings 24 amp 26 must be replaced when replacing gun sub module 2 Mount the new gun module tightening the retaining screws 22 This will allow fluid and air passages to seal with no contamination BINK SPRAY PATTERN TROUBLESHOOTING Do not exceed 100 psi gun inl
12. et pressure Use air nozzle test gauge assembly to determine and verify exact nozzle operating air pressure ACTION PROBLEM CAUSE Fluttering Spray Pattern Striping Spray Fingers Irregular Pattern Pattern pushed to one side same side of air cap gets dirty HVLP AIR NOZZLES 90P Insufficient fluid supply Air in paint supply line Tip partially plugged Fluid builds up on tip or tip partially plugged On defective side of pattern air horn holes are plugged On defective side of pattern air horn holes are plugged Adjust fluid regulator or fill fluid supply tanks Check and tighten pump siphon hose connections bleed air from paint line Clean or replace tip assembly Clean tip Clean air horn holes with solvent and a soft brush Clean air horn holes with solvent and a soft brush or toothpick NOZZLE AND NEEDLE SELECTIONS HVLP AIR NOZZLE HVLP AIR NOZZLES 93P HVLP AIR NOZZLES 95P GUN NOZZLE NOZZLE GUN NOZZLE NOZZLE GUN NOZZLE NOZZLE INLET AIR FLOW ATOMIZING INLET AIR FLOW ATOMIZING INLET AIR FLOW ATOMIZING PSI SCFM PSI PSI SCFM PSI PSI SCFM PSI 5 0 4 0 3 0 8 0 5 5 3 0 20 0 11 0 3 0 7 0 4 5 5 0 11 5 7 0 5 0 30 0 15 7 5 0 10 0 5 0 7 0 14 5 8 0 7 0 38 0 17 5 7 0 12 0 5 5 9 0 17 0 9 5 9 0 45 0 19 6 9 0 15 0 6 0 10 0 18 0 10 0 10 0 50 0 22 5 10 0 HVLP AIR NOZZLES 92P HVLP AIR NOZZLES 94P HVLP AIR NOZZLES 100P GUN NOZZLE NOZZLE GUN NOZZLE NOZZLE GUN NOZZLE NOZZLE INLET AIR F
13. is equipment Use only genuine Binks parts e Do not exceed the maximum working pressure of the lowest rated system component THE MAXIMUM RATING OF THE MAG HVLP GUN IS 120 P S I DO NOT EXCEED THE FLUID PRESSURE RATING e Route all hoses away from all sharp edges moving parts hot surfaces and high traffic areas e Do not use hoses to pull the equipment e Use only Binks approved hoses e Use only solvents compatible with hoses and wetted parts of the equipment used e Comply with all applicable local state and national fire electrical and other safety regulations e Improper grounding poor air ventilation open flame or sparks can cause a hazardous condition and result in fire or explosion and cause serious injury NOISE LEVELS e The A weighted sound level of spray guns may exceed 85 dB A depending on the setup being used It is recommended that ear protection is worn at all times when spraying PROP 65 WARNING e WARNING This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm The automatic Spray Gun models listed in the following declaration of conformity may be used in some potentially explosive atmospheres ONLY when the special conditions for safe installation and operation have been followed as expressed in this user manual Part Sheet These models are approved to ATEX regulations 94 9 EC protection level Il 2 G X Suitable for us
14. lacing fluid nozzle Service or replace fluid nozzle assembly and reassemble in reverse order Lubricate needle with Copper PTFE Grease 540395 before inserting through fluid cartridge AND SERVICE INSTRUCTIONS 2 Turn retaining ring 19 counter clockwise and remove 3 Remove air cap 20 4 Turn fluid nozzle 21 counterclockwise and remove 5 Service or replace and reassemble in reverse order REPLACING FLUID CARTRIDGE ASSEMBLY Service symptoms e Fluid leaking from weep port 1 Turn end cap 3 counterclockwise and remove it with the piston and needle return spring from the piston body 25 2 Remove fluid needle assembly 8 3 Using the two 8 32 screws 41 provided in loose parts bag thread the 8 32 screw into the two threaded holes in the back of the piston Pull the two threaded screws and remove the piston 4 Place the supplied 3 8 deep socket over fluid cartridge assembly 18 and turn it counter clockwise 5 Remove and reassemble in reverse order using the new fluid cartridge assembly REPLACING O RINGS ON PISTON ASSEMBLY Service symptoms e Atomizing air not cycling off e Air not actuating fluid 1 Turn end cap 3 counterclockwise and remove it with the piston return spring 7 and needle return spring 4 from the piston body 25 2 Remove fluid needle assembly 8 3 Using the two 8 32 screws 41 provided in loose parts bag thread the two 8 32 screws into the two thread
15. n or subjecting it to a flood wash of cleaning solvent Contact with solvents may induce o ring swelling beyond their specification sizes and cause subsequent malfunction of the gun Use white lithium based grease to lubricate all o rings and moving parts before reassembly into the gun body To further protect the environment avoid storing solvents or solvent soaked wipes such as those used for surface preparation and cleanup in open or absorbent containers TROUBLESHOOTING Numbers in parentheses refer to individual items shown on the exploded drawing on page 7 A CAUTION Never use metal instruments to clean or scrape fluid or air nozzles These parts have been carefully machined and altering their shape will cause faulty spray AWARNING Be sure to follow all safety precautions described on page 2 before working on the spray gun Never work on the spray gun until fluid pressure has been relieved throughout the system and the power or air supply for the fluid pump has been disconnected Always test the repaired gun for leaks with low pressure fluid before use SERVICING REPLACING FLUID NOZZLE AND FLUID NEEDLE ASSEMBLY Service symptoms e Build up on air cap or clogged fluid nozzle assembly e Fluid nozzle not sealing properly 1 Remove valve control 1 Lock nut 2 and needle return spring 4 Pull item 8 needle assembly back or remove it so you don t damage the needle when servicing or rep
16. omizing air is separated they both activate ON and OFF with cylinder air control SET UP FOR SPRAYING Safe connection e Verify that the gun is grounded per the automated machine manufacturer s recommendations Connect fluid hose to the manifold e Use 3 8 diameter material hose e Fluid fitting from hose assembly to 1 4 NPT fluid inlet on manifold is not furnished e 1 4 diameter hose is recommended for low viscosity materials Connect atomizing air to the manifold e Install 1 4 NPS m x 1 4 NPT m fitting furnished loose in atomizing air port e Use 5 16 diameter or larger Air hose Connect cylinder air hose to manifold e Install 1 8 NPT m x 1 4 tube fitting furnished loose in cylinder air port Controlling the material flow e Increasing the material pressure will increase the flow rate e Correct fluid tip size helps insure correct material flow Adjusting the spray pattern e By adjusting the side port control you can get the full range of pattern adjustment when you have proper fluid and air flow e When set up for remote fan air you achieve a larger pattern by increasing the air pressure to the fan port GENERAL SPRAY INSTRUCTIONS 1 Minimum cylinder actuating pressure is 50 PSI 2 To reduce overspray and obtain maximum efficiency always spray with the lowest possible fluid air pressure that produces an acceptable pattern 3 Cylinder air line from the gun manifold to the
17. r min Actuating Pressure 100 psi 6 8 bar max Gun Body Stainless Steel Aluminum Fluid Path Stainless Steel Fluid Inlet and Outlet Size 1 4 NPT F thread Air Inlet Size Atomizing Air 1 4 NPT F manifold body 1 4 NPT x 1 4 NPS M fitting loose Fan Air 1 4 NPT F manifold body 1 4 soc head plug M fitting loose Cylinder Air 1 8 NPT F manifold body 1 8 NPT x 1 4 O D tube fitting loose Gun Weight with Manifold 2 8 Ibs 1 27 kg Gun Mounting Hole 1 2 Dia The MAG HVLP is approved to ATEX level II 2 G X and is suitable for use in Zones 1 and 2 PROP 65 WARNING WARNING This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm CA PROP Replaces Part Part Sheet Sheet 77 2803R 10 77 2803R 11 BINK A WARNING HIGH PRESSURE CAN CAUSE SERIOUS INJURY IF EQUIPMENT IS INSTALLED OR USED INCORRECTLY READ UNDERSTAND AND OBSERVE ALL WARNINGS AND INSTRUCTIONS IN THIS MANUAL OPERATE EQUIPMENT ONLY AFTER ALL FLAMMABLE EXPLOSIVE AND TOXIC VAPORS INSTRUCTIONS ARE CLEARLY UNDERSTOOD In this part sheet the words WARNING CAUTION and NOTE are used to emphasize important safety information as follows A WARNING A CAUTION Hazards or unsafe practices which could Hazards or unsafe practices which could result in minor personal injury product or property damage Important installation operation or mainten