1. If the field Use Gateway in the Gateway section is checked it is possible to Port 10001 insert the IP Address of the gateway in the field below Gateway In the field Remote IP for MASTER IP it is necessary to insert the IP Use Gateway address of the remote device in this mode in addition to the set up of the 4g 4EB 4 device s line EL IL In the field COM port setup you can select the COM port Once the parameters are set up configure the serial port to be used push the download button perform a cycle of power on and wait for the software to complete the proper set up Ver 3 100 ADFweb com Srl IT31010 Mareno Treviso COM port setup COMI lad Figure 7 Tunnel Point to Multipoint Slave Side window INFO www adfweb com rms z 5 Ethernet to RSZ232 485 Seral Part Setup Baud Hate Parity 9600 iv none m Stop Bits Flow control E E nane IY MASTER IP Remote IF 182 188 i Phone 39 0438 30 91 31 Vy User to RS232 RS485 Ethernet Document code MN67120 ENG Revision 2 003 Page 12 of 15 Industrial Electronic Devices CHARACTERISTICS OF THE CABLES The connection with the Ethernet socket must be with a Ethernet Cable with a RJ45 Plug It is recommended that the RS232 Cable not exceed 15 meters a Cabling D Cabling 1 For RS232 Comunication use 1 For RS232 Comunication use With flow control Without flow control 2 F
2. When launching the SW67120 the Select Modality window appears Fig 3 Select Modality Select the Operating Modality The following modalities are available gt Remote COM Port gt Tunnel Point to Point gt Tunnel Point to Multipoint f Remote COM port Ethamat to RESZ232485 Sarai F m Etienne in K3232 485 E hernet to ReSzXZI4RS Tunnel Point to Paint aurinda Tal Wusrr a bourg Ethernet te RS232485 Eemal t 2a 24s St AVE P eriale E ema to R3232 485 SLAVE HY there io RS232 4B5 Tunnel Paint ta Multipoint LAVE Ver 3 100 Figure 3 Select Modality window ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 Vy User to RS232 RS485 Ethernet Document code MN67120 ENG Revision 2 003 Page 8 of 15 Industrial Electronic Devices REMOTE COM PORT It consists in a configuration in which the device is generally controlled by a PC that is Baisi ii connected using the protocol of the TCP line on the 10001 port It writes bytes that automatically are sent on serial line and each byte read from the serial port is transmitted through the line to the connected PC Configuration Parameters The address of the device line and the serial line parameters must be set in the setting E window Fig 4 which relates to this mode The means of the fields for EtherNet to RS232 485 LAN config are Inthe field I
3. instrument can represent a potential hazard if they are inappropriately installed and operated by personnel untrained These instructions refer to residual risks with the following symbol This symbol indicates that non observance of the safety instructions is danger for people to serious injury or death and or the A possibility of damage CE CONFORMITY The declaration is made by us You can send an email to support adfweb com or give us a call if you need it ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 Vy User to RS232 RS485 Ethernet Document code MN67120 ENG Revision 2 003 Page 4 of 15 Industrial Electronic Devices CHARACTERISTICS Ethernet to RS232 RS485 is a professional device for using COM port through Ethernet line This device allows the following configurations gt Remote COM Port gt Tunnel Point to Point Ethernet bridge for a serial line gt Tunnel Point to Multipoint typical 485 connection with Master and slaves but through Ethernet line This device can be provided on request with a specific software it can be a gateway for special serial protocol HD67148 gt gt gt gt gt gt POWER SUPPLY Recommended Power Supply Galvanic isolation between Ethernet and RS485 Rail DIN Ethernet 10 100 Auto sensing MAX Baud Rate 115 200 bps RS485 side Temperature range 40 C to 85 C EMS EN 61000 6 2 Caution Not reverse the pola
4. NT TUNNEL POINT TO MULTIPOINT MASTER SIDE TUNNEL POINT TO MULTIPOINT SLAVE SIDE CHARACTERISTICS OF THE CABLES MECHANICAL DIMENSIONS ORDER CODE ACCESSORIES DISCLAIMER OTHER REGULATIONS AND STANDARDS WARRANTIES AND TECHNICAL SUPPORT RETURN POLICY PRODUCTS AND RELATED DOCUMENTS ADFweb com Srl IT31010 Mareno Treviso D HB ee oe C NUK KRWWWNHPOVANDUBARWNNNNNG User to RS232 RS485 Ethernet Document code MN67120 ENG Revision 2 003 Page 2 of 15 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obtain the most recently updated document note the document code that appears at the top right hand corner of each page of this document With this Document Code go to web page www adfweb com download and search for the corresponding code on the page Click on the proper Document Code and download the updates To obtain the updated documentation for the product that you own note the Document Code Abbreviated written Doc Code on the label on the product and download the updated from our web site www adfweb com download REVISION LIST Revision Date Author Chapter Description 1 005 19 06 2005 Ddt Ali HOS MES de changed 1 006 22 06 2007 AV All Revision 1 007 26 06 2007 AV All Revision 1 008 11 07 2007 Av All accessories cod
5. P the IP address of the converter is defined Inthe field SubNet Mask the Subnet Mask of the converter is defined Inthe field Port the Port of the converter is defined EtherMet ta H5232 485 LAN contig Serial Part Setup The means of the fields for Serial Port Setup are IF gt Inthe field Baud Rate the velocity of the serial port is 192 168 1 200 Baud Rate Parity defined SubNet Mask J00 w Labs v Inthe field Parity the parity of the serial port is defined 25S 255 1255 n SRL T UP op Bits Flow control Inthe field Stop Bits the number of stop bits is defined You can choose l m m i between 1 and 2 In the field Flow Control you can choose the flow control Par 10001 among none XON XOFF CTS RTS or XON XOFF pass Gateway Use Gat If the field Use Gateway in the Gateway section is checked it is possible to insert the Kise Galana IP Address of the gateway in the field below We tee In the field COM port setup you can select the COM port Figure 4 Once the parameters are set up configure the serial port to be used push the download Ver 3 100 COM port setup LOMI Iv button perform a cycle of power on and wait for the software to complete the proper set up Figure 4 Remote COM port window ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 Vy User to RS232 RS485 Ethernet Do
6. User to RS232 RS485 Ethernet Document code MN67120 ENG Revision 2 003 Page 1 of 15 Industrial Electronic Devices User Manual Revision 2 003 English RS232 RS485 Ethernet Converter mm Order Code HD67120 for Website information www adfweb com Product HD67120 for Price information www adfweb com Price HD67120 Benefits and Main Features l l l Similiar For others Converter Adapter Interfacing directly to 485 without other adaptor _ RS232 RS485 Rd et he following link Galvanic isolation between Ethernet and 232 485 bus oe ee Protocol independent USB RS485 s s S Iso the following link Suitable for supervision software www adfweb com Product HD67119 SCADA HMI and the connection to a Personal Computer i Do you have an your customer protocol Automated control of the line directions eee creirallowing link c adfweb ProductzHD67003 Easy to use software configuration BEEN c i Do you need to choose a device do you want help Compatible with Windows 98 ME 2000 XP DO Er ewing link www adfweb com Cmd helpme ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 Industrial Electronic Devices INDEX INDEX UPDATED DOCUMENTATION REVISION LIST WARNING TRADEMARKS SECURITY ALERT CHARACTERISTICS POWER SUPPLY SOME EXAMPLES CONNETION SCHEME SET UP OF THE DEVICE REMOTE COM PORT TUNNEL POINT TO POI
7. cument code MN67120 ENG Revision 2 003 Page 9 of 15 Industrial Electronic Devices TUNNEL POINT TO POINT It is a mode that allows the extension of a serial line using a LAN line The two devices in this mode must be configured in a coherent way between the two or in such a way that both read the IP address of the other one This mode allows exchanges of packets with UDP protocol Select Modality Configuration Parameters The address of the device line and the serial line parameters must be set in the setting window Fig 5 which relates to this mode senale Ethene to amp 5232 485 The means of the fields for EtherNet to RS232 485 LAN config are Inthe field IP the IP address of the converter is defined Inthe field SubNet Mask the Subnet Mask of the converter is defined Inthe field Port the Port of the converter is defined The means of the fields for Serial Port Setup are Inthe field Baud Rate the velocity of the serial port is EtherMet ta H5232 485 LAM contig Serial Port Setup defined IP Inthe field Parity the parity of the serial port is defined T Baud Fate Parity Inthe field Stop Bits the number of stop bits is defined You can We Wie WI ee saat A ae choose between 1 and 2 SubNet Mask 3600 v EHE iv Inthe field Flow Control you can choose the flow control among 255 255 255 0 SIE Elec none XON XOFF CTS RTS or XON XOFF pass Pott 10001 i M
8. e 6 of 15 Industrial Electronic Devices M CONNECTION SCHEME Jumper2 Termination Modbus Line Connector4 Port RS232 D SUB9 Male EN RS232enable EE RS485 enable PIN2 RX PIN3 TX PIN4 GND Used for A Programmation Port B RS232 Communication To connect the device to the COM port of a PC in order to set it you have to use the programming cable AC34107 Or a cable made as showed here 0600000009090 GND HD67120 PC D SUB9 COM Port eoo000000000 OO Alternative Power Supply V Positive wire 12 VAC min 8v max 19v 4 VA 24 VDC min 8v max 35v 4 Watt S Shield to Isolated Ground B Negative wire A Positive wire Jumper1 Termination Modbus Line HER Open EE 220 ohm Figure 2 Connection scheme for HD67120 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User to RS232 RS485 Ethernet Document code MN67120 ENG Revision 2 003 Page 7 of 15 Industrial Electronic Devices SET UP OF THE DEVICE ADFweb com supplies the SW67120 software for the configuration of the device The software is downloadable on the site http www adfweb com home download download asp This manual is referenced to the last version of the software present on our web site Connect the RS232 cable from your personal computer to the device at the RS232 port Put the jumper on the enabled RS232 see Figure 2
9. e changed 2 000 12 07 2007 Av All New document format 2 001 20 07 2009 MI All Revision 2 002 5 07 2010 Par All Revision 2 003 13 02 2013 Nt All Added new chapters WARNING ADFweb com reserves the right to change information in this manual about our product without warning ADFweb com is not responsible for any error this manual may contain TRADEMARKS All trademarks mentioned in this document belong to their respective owners INFO www adfweb com Phone 39 0438 30 91 31 Vy User to RS232 RS485 Ethernet Document code MN67120 ENG Revision 2 003 Page 3 of 15 Industrial Electronic Devices SECURITY ALERT GENERAL INFORMATION To ensure safe operation the device must be operated according to the instructions in the manual When using the device are required for each individual application legal and safety regulation The same applies also when using accessories INTENDED USE Machines and systems must be designed so the faulty conditions do not lead to a dangerous situation for the operator i e independent limit switches mechanical interlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of this equipment and who have appropriate qualifications for their job RESIDUAL RISKS The device is state of the art and is safe The
10. hone 39 0438 30 91 31 Vy User to RS232 RS485 Ethernet Document code MN67120 ENG Revision 2 003 Page 14 of 15 Industrial Electronic Devices DISCLAIMER All technical content within this document can be modified without notice The content of the document content is a recurring audit For losses due to fire earthquake third party access or other accidents or intentional or accidental abuse misuse or use under abnormal conditions repairs are charged to the user ADFweb com S r l will not be liable for accidental loss of use or inability to use this product such as loss of business income ADFweb com S r l shall not be liable for consequences of improper use OTHER REGULATIONS AND STANDARDS WEEE INFORMATION Disposal of old electrical and electronic equipment as in the European Union and other European countries with separate collection systems mm his symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycling of electrical and electronic equipment If the product is disposed correctly you will help prevent potential negative environmental factors and human health which could otherwise be caused by inappropriate disposal The recycling of materials will help to conserve natural resources For more information about recycling this product please contact your local city office your household was
11. iuis m If the field Use Gateway in the Gateway section is checked it is possible to insert the IP Address of the gateway in the field below Gateway Tunneling Use Gateway Secrets Tei In the field Remote IP for Tunneling it is necessary to insert the IP address 192 fiee 192 188 of the remote device in this mode in addition to the set up of the device s line In the field COM port setup you can select the COM port Once the parameters are set up configure the serial port to be used push the Ver 3100 COM port setup COM download button perform a cycle of power on and wait for the software to complete the proper set up Figure 5 Tunnel Point to Point window ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 Vy User to RS232 RS485 Ethernet Document code MN67120 ENG Revision 2 003 Page 10 of 15 Industrial Electronic Devices TUNNEL POINT TO MULTIPOINT MASTER SIDE This mode allows a serial line to be extended into sections using a LAN line s where the device is on the side of the one that controls the line as Master and the others are on the client s side In order to configure a device as Master the field Master Side must be checked In the case of the master it is not necessary to provide any other address because the packets are sent as broadcasts The address of the device line and the serial line parameters must be set in
12. or configuration device 2 For configuration device ul f 9 f f N m m co NC NC E m m Ld i HD67120 PC HD67120 PC D SUB9 COM Port D SUB9 COM Port Figure 8 RS232 cabling configuration For RS232 communication without flow control and for configure the device use the cabling configuration illustrated in fig 7 a For RS232 communication with flow control and for configure the device use the cabling configuration illustrated in fig 7 b The connection with the RS485 socket must be done with a twisted and shielded cable The terminal resistor must be inserted when the HD67120 is at the end of the line using the Terminator jumper ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 iY User to RS232 RS485 Ethernet Document code MN67120 ENG Revision 2 003 Page 13 of 15 Industrial Electronic Devices MECHANICAL DIMENSIONS oe6ce0c0e0000000 I E gX e vec0000000000 mE EHE mH um 71 mm 60 mm 2 79 inch 2 36 inch Housing PVC Weight 200g Approx Figure 9 Mechanical dimensions scheme ORDER CODE Order Code HD67120 RS232 RS485 Ethernet Converter ACCESSORIES Order Code AC34001 Rail DIN Power Supply 220 240V AC 50 60Hz 12 V AC Order Code AC34002 Rail DIN Power Supply 110V AC 50 60Hz 12 V AC Order Code AC34104 European Input Power Supply 230V AC 50Hz 12 V DC ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com P
13. rity power Vmin Vmax Vmin Vmax Sv 35v 8v 19v ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL Industrial Electronic Devices SOME EXAMPLES Annie Rance COM Phor Equivalent Layout Simple amp annectian from PC to 232 435 device BSohilson Equivalent Layout s e e Master Slave C Gonrnertan With R5485 Line amp Equivalent Layout v 9 munie correcta between 232 445 tm anothar 24285 device Figure 1 Some examples ADFweb com Srl IT31010 Mareno Treviso User to RS232 RS485 Ethernet Document code MN67120 ENG Revision 2 003 Page 5 of 15 Ethernet 10 100 LAN Typical Applications Remote COM Port Qo Rea nr qH5 R35232 veia Ae weh cami PC with adda remote CON port Serial Device Serial he COMA and COMMS Le on COM PC Le 0n COMS PC Typical Applications Tunnel Point to Multri Point R523 nr H amp S4A4HE5 Serial Slave Serial Shave Serial Haster Flow daia Typical Applications Fine dara Tunnel Point to Point Ethemet 10 100 LAN i MAH ODF Va OPE HITS Electrical isolation Rel Bed RS232 ar Pods LU RE Fa cy RSaABS or Hoes Serial Device GB S Device Senal Device Serial Device INFO www adfweb com Phone 39 0438 30 91 31 iy User to RS232 RS485 Ethernet Document code MN67120 ENG Revision 2 003 Pag
14. t is no longer under warranty you will receive a repair estimate PRODUCTS AND RELATED DOCUMENTS Part Description URL HD67118 Converter RS232 to RS485 Isolated www adfweb com Product HD67118 HD67119 Converter USB 2 0 to RS485 Isolated www adfweb com Product HD67119 HD67507 Gateway Modbus TCP Server to RTU Master www adfweb com Product HD67507 HD67510 Gateway Modbus TCP Client to RTU Slave www adfweb com Product HD67510 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31
15. te disposal service or the shop where you purchased the product RESTRICTION OF HAZARDOUS SUBSTANCES DIRECTIVE 4 The device respects the 2002 95 EC Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment commonly referred to as Restriction of Hazardous Substances Directive or RoHS 2002 95 EC CE MARKING C The product conforms with the essential requirements of the applicable EC directives ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 Vy User to RS232 RS485 Ethernet Document code MN67120 ENG Revision 2 003 Page 15 of 15 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT For fast and easy technical support for your ADFweb com SRL products consult our internet support at www adfweb com Otherwise contact us at the address support adfweb com RETURN POLICY If while using your product you have any problem and you wish to exchange or repair it please do the following 1 Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem 2 Send the product to the address provided with the PRN having prepaid the shipping costs shipment costs billed to us will not be accepted If the product is within the warranty of twelve months it will be repaired or exchanged and returned within three weeks If the produc
16. the setting window Fig 6 which relates to this mode The means of the fields for MASTER LAN CONFIG are see gt Inthe field IP the IP address of the converter is defined s ee net in RG232 p5 gt In the field SubNet Mask the Subnet Mask of the converter is defined Inthe field Port the Port of the converter is defined MASTER SIDE MASTER LAN CONFIG Seral Part Setup The means of the fields for Serial Port Setup are E Inthe field Baud Rate the velocity of the serial port is 13e Tbe f Baud Hate Parity defined SubNet Mask 3500 none Inthe field Parity the parity of the serial port is defined lons 255 lJas m Inthe field Stop Bits the number of stop bits is defined You can tt 3top Bits I Flow control choose between 1 and 2 4000 1 Iv none gt Inthe field Flow Control you can choose the flow control among EUN none XON XOFF CTS RTS or XON XOFF pass Gateway Use Gateway If the field Use Gateway in the Gateway section is checked it is possible to insert the IP Address of the gateway in the field below I32 Tee In the field COM port setup you can select the COM port Once the parameters are set up configure the serial port to be used push the download button perform a cycle of power on and wait for the software to complete the proper set up Ver 3 100 COM part setup Figure 6 Tunnel Point to M
17. ultipoint Master Side window ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL Industrial Electronic Devices TUNNEL POINT TO MULTIPOINT SLAVE SIDE SS e LLLLL Select Modality For configure a device as Slave the field Master Side of Operating Modality section should not be checked In the case of the slave it is necessary to provide the IP address of the Master Converter Document code MN67120 ENG User to RS232 RS485 Ethernet Revision 2 003 Page 11 of 15 Configuration Parameters The address of the device line and the serial line parameters must be set in the setting window Fig 5 which relates to this mode MASTER The means of the fields for CLIENT LAN CONFIG are gt In the field IP the IP address of the converter is defined Inthe field SubNet Mask the Subnet Mask of the converter is defined Inthe field Port the Port of the converter is defined The means of the fields for Serial Port Setup are ie gt Inthe field Baud Rate the velocity of the serial port is C MASTER SIDE defined Inthe field Parity the parity of the serial port is defined pu ini Inthe field Stop Bits the number of stop bits is defined You can i choose between 1 and 2 I3 Tee Inthe field Flow Control you can choose the flow control among subMet Mask none XON XOFF CTS RTS or XON XOFF pass 255 255 255

Download Pdf Manuals

image

Related Search

Related Contents

Inscription dans îa iiste électora`ie  Sharp MX-M550 Government Compliance    Satellite M70 User`s Manual  16x16 Cat 5 A/V Matrix Switch VM1616T User Manual  和光純薬時報 Vol.82 No.3(2014.07)  Acer Aspire AS7551-7422 : Free Download, Borrow, and Streaming : Internet Archive  Istruzioni d’uso  Philips DIS702    