Home

SHDTU03b-ET100BS User Manual

image

Contents

1. 13 3 3 CONSOLE SCREEN CONVENTION 8 hh nennen ene 13 4 CONFIGURATION 15 4 1 CONFIGURE DEVICE nennen enhn ehe seen 606060600660 esse 16 4 2 CONFIGURE ANNEX nn 16 4 3 CONFIGURE DSL RATE nnne 16 4 4 CONFIGURE DSL MODE 99 nennen sees 16 4 5 CONFIGURE LAN INTERFACE nnne nhe nnne nnne 16 4 6 CONFIGURE VLAN SETTING sees sess en 60 esse 17 4 7 FACTORY DEFAULT SETTING sees entente set 17 4 8 SAVE CONFIGURATION 00 6006 sees senses reete seen 18 5 PERFORMANCE MONITORING 18 6 19 1 Description The SHDTUOSb ET100BS a SHDSL Single pair High bit rate Digital Subscriber Line LAN Extender provides a broadband transmission with bandwidth up to 5 696Mbps over a single pair of copper wires for LAN connection between two local area netwo
2. 8 mp 1 Table1 14 10 100 Base Tpin out Pin NO Function Data Direction Designation 1 TX Transmitting Data Toward the LAN network TX 2 TX Transmitting Data Toward the LAN network TX 3 RX Receiving Data Toward the LAN Equipment 6 RX Receiving Data Toward the LAN Equipment RX 2 SHDTUOSb ET100BSSDesktop is shipped with the following contents One 110 220V power adaptor B One SHDTUO03b ET100BS User Manual If configured from the Craft port your are encouraged to use the virtual terminal emulator from Window Microsoft and set the COM Port of PC to the following communication parameters DTE speed 38 4Kbps 8 Data Bit Non Parity Bit One Stop Bit No Flow Control Selection of VT 100 for Terminal Configuration 10 3 To access the VT 100 console screen check that the CID port speed matches the terminal emulation program currently being used The default value for the CID port is 38 4k bps 8 data bit No Parity 1 stop bit The VT 100 console uses a blinking cursor to select various menus sub menus and fields within those menus To pop up the console press the Enter key several times to display the Log On Screen illustrated in the following screen Main Device Type Line CNT Data Rate Port 1 Port 2 Port 3 Port 4 L COT SYNC 4032 kbps LINK DOWN DOWN DOWN R RT SYNC 4032 kbps LINK DOWN LINK DOWN
3. G SHDSL bis LAN EXTENDER 1 Configration lt DIR gt 2 Status lt DIR gt 3 Inventory lt DIR gt 1 3 Select Enter Accept ESC Escape SPACE Screen Refresh Main Screen To select a specific field or navigate the console screen refer to the table below for further details Keyboard Command Description Tab Tabs to previous item Space Refreshes the entire screen Esc Escapes to previous page 1 N Fields enclosed in brackets offer a list of selections Enter Validates the fields selected 11 Viewing from Main Menu the second layer 1 Configuration 2 Status and 3 Inventory and all its tributary parameters are shown in Figure 3 1 Figure 3 1 Menu Tree Main Menu gt gt 1 Configuration gt gt 1 Device COT RT gt gt 2 Annex Annex F gt gt 3 DSL Rate 3 89 gt gt 4 051 Mode Fixed gt gt 5 LAN Port gt gt 1 Auto Negotiation Disable Enable gt gt 2 Speed 10M 100M gt gt 3 Duplex Half Full gt gt Flow control Eable Disable gt gt 5 Packet size 1518 1522 1536 1784 6 VLAN setting gt gt 1 Mode Unware Aware gt gt 2 P P Segmented Channel Disable Enable gt gt 3Jngress VID Range Start 0 4095 gt gt 4 Ingress VID Range length 0 4095 gt gt 5 Port 1 Bandwidth value 1 89 gt gt 6 Port 2 Bandwidth value 1 89 gt gt 7 Port 3 Bandwidth value 1 89 gt gt 8 Port 4 Bandwidth value 1
4. 1 1 1 PRODUCT DESCRIPTION nnne nennen nnne nne n enne tete nesses sees eet ettet esse tene rennen nnn 7 1 2 SPECIFICATION EDDDIDDIDIEPTPPPP ees 7 1 3 9 00060006060 06 600660006 0606 660666066600 es sees 8 1 4 SHDSL SYSTEM COMPONENTS 6000000 0 0 seen nun 8 1 5 FRONT PANEL LEDS INDICATORS HH HII 8 1 6 REAR PANEL 6 5 5 00060006006 6006 600000000 es seen ees 9 MEN Weiler 10 2 1 CHECKING PACKAGE CONTENTS nnne ene nennen enne 10 2 2 PREPARE FOR INSTALLATION mme hn hhehenen eens eens eens eens enne 10 Kee 11 3 1 ILNMUMEHUIBEEEEPEPTT 12 CEPMAVFANBSIENUBDEIDESESEETM
5. Line CNT Data Rate Port 1 Port 2 Port 3 Port 4 L COT SYNC 4032 kbps LINK DOWN DOWN DOWN R RT SYNC 4032 kbps LINK DOWN DOWN DOWN G SHDSL bis LAN EXTENDER E 1 Device Type COT 2 Annex Annex 3 DSL Rate 03 4 DSL Mode Fixed 5 LAN port lt DIR gt 6 VLAN setting lt DIR gt 7 Factory Ddfault lt CMD gt 8 Save lt CMD gt 1 COT 2 RT Input 1 Table 5 1Configure Parameters Screen Content Description 1 Device Type Specifies whether the unit is configured as COT or Entry COT RT 2 Annex Sets the transmission mode for SHDSL Entry Annex F 3 DSL Rate Specifies data rate for DSL Data rate could be configured in multiple of 64k N23 89 4 DSL Mode Sets DSL Mode 5 LAN Port Configure LAN Port 6 VLAN setting VLAN setting 7 Factory Default Sets SHDTU03B ET100BS to factory default 8 Save Save the parameters to SHDTUOSB ET100BS 15 To configure the Device Type apply the menu selection sequence Local gt gt Configure Move cursor to 1 Device Type and specify whether the unit is configured as COT or RT To configure the Annex Mode apply the menu selection sequence Local Configure Move cursor to 2 Annex and specify whether the DSL is configured as Annex F To configure the DSL Rate apply the menu selection sequence Local Configure Move cursor to 3 DSL Rate and Specifies data rate for DSL Data rate could be
6. This chapter provides identity information for the unit s services and revision state as illustrated in the figure below To access this maintenance service select 3 Inventory of main menu and hit Enter key to take effect Main Inventory Device Line Data Rate Port 1 Port 2 Port 3 Port 4 C COT SYNC 4032 kbps LINK DOWN DOWN DOWN R RT SYNC 4032 kbps LINK DOWN DOWN DOWN G SHDSL bis LAN EXTENDER 1 version 10 2 S W version 08 3 DSL version 06 00 02 1 3 Select ltem Enter Accept ESC Escape SPACE Screen Refresh Item Description 1 S W Version Displays the software version currently used for the unit 2 Version Displays the hardware version of circuitry 3 DSL Vserion Displays the DSL version of circuitry 19 TC union www ctcu com E info ctcu com F 886 2 2659 0237 T 886 2 2659 1021
7. User Manual SHDTU03b ET100BS 1 pair GSHDSL LAN Extender CTC UNION TECHNOLOGIES CO LTD LEGAL The information in this publication has been carefully checked and is believed to be entirely accurate at the time of publication CTC Union Technologies assumes no responsibility however for possible errors or omissions or for any consequences resulting from the use of the information contained herein CTC Union Technologies reserves the right to make changes in its products or product specifications with the intent to improve function or design at any time and without notice and is not required to update this documentation to reflect such changes CTC Union Technologies makes no warranty representation or guarantee regarding the suitability of its products for any particular purpose nor does CTC Union assume any liability arising out of the application or use of any product and specifically disclaims any and all liability including without limitation any consequential or incidental damages CTC Union products are not designed intended or authorized for use in systems or applications intended to support or sustain life or for any other application in which the failure of the product could create a situation where personal injury or death may occur Should the Buyer purchase or use a CTC Union product for any such unintended or unauthorized application the Buyer shall indemnify and hold CTC Union Technologies and its off
8. Menu Sequence Cfg Device Type Line Data Rate Port 1 Port 2 Port 3 Port 4 Status Message L COT SYNC 4032 kbps LINK DOWN DOWN DOWN R RT SYNC 4032 kbps LINK DOWN LINK DOWN Ee GSHDSL bis LAN EXTENDER lt lt lt 1 Device COT 2 Annex Annex F 3 DSL Rate 03 Sub Menu 4 DSL Mode Fixed Result Display 5 LAN port DIR 6 VLAN setting DIR 7 Factory Ddfault CMD 8 Save CMD Input Field Function Key 1 COT 2 RT Input 1 1 6 Select ltem Enter Accept Item ESC Escape SPACE Screen Refresh 14 4 Configuration This chapter provides instructions on how to access and configure your SHDTUOS3b ET100BS displaying configuration options restoring to factory default and saving the configuration In other words the provisioning parameters for each SHDSL unit could also only be provided through the CID and SHDTU03b ET100BS Desktop functioning as STU C or as STU R In case of STU R is connected to STU C successfully then STU R will download the configuration automatically It means the configuration of the both units are same paramenters except STU C and STU R The first Item on the Main Menu Screen is Configuration option The Configuration Screen below allows you to view set or make changes to certain specific parameters about the unit in service The following Screen allows you to view and change the parameters of SHDTU03b ET100BS Cfg Device
9. 89 gt gt 7 Default gt gt 8 gt gt 2 Status gt gt 1 Device Type gt gt 2 gt gt 3 DSL Rate 64 5696 kbps gt gt 4 5 0 20 gt gt 5 DSL Status Idel SYN Handshaking gt gt 3 Inventory gt gt 1 version gt gt 2 S W version 12 The Main Menu Screen illustrated below Main Device Type Line CNT Data Rate Port 1 Port 2 L COT SYNC 4032 kbps LINK DOWN SYNC 4032 kbps LINK DOWN G SHDSL bis LAN EXTENDER 1 Configration lt DIR gt 2 Status lt DIR gt 3 Inventory lt DIR gt 1 3 Select Enter Accept ESC Escape SPACE Screen Refresh The Console Screen Convention contains five user operating areas Menu Sequence The one line top most area that shows sequence for bringing the menu to the current hierarchy Status Alarm message This is the two line area above the double dotted line that provides network and user interface status and alarm message Sub Menu or Result Display This is the area above the single dotted line that provides content of sub menu or display of performance data and testing result Input field The area beneath the dotted line that shows options specific tomenu or sub menu items and allows user to enter value desired Function Keys The area right beneath the input field that lists the function keysspecific to the operation of the menu currently displayed 13
10. configured in multiple of 64k Annex N 3 89 To configure the DSL Mode apply the menu selection sequence Local Configure Move cursor to 4 DSL Mode is Fixed To access LAN Port apply the menu selection sequence Local gt gt Configure gt gt LAN port gt gt as shown below Mainl Cfg LAN Port Device Line CNT Data Rate Port 1 Port 2 Port 3 Port 4 C COT SYNC 4032 kbps LINK DOWN DOWN DOWN R RT SYNC 4032 kbps LINK DOWN DOWN DOWN LL m G SHDSL bis LAN EXTENDER 1 Auto Negotiation Disable 2 Speed 100M 3 Duplex Full 4 Flow control Enable 5 Packet size 1518 1 Disable 2 Enable Input 1 1 4 Select ltem Enter Accept ESC Escape SPACE Screen Refresh 16 The Ethernet interface pameters described now are provided in the following table Table 5 2 LAN Port Screen Content Item Description 1 Auto Negotitation Specifies whether the Ethernet interface is being operating in auto detecting or Manually mode Entry Disable Enable 2 Mode Specifies the operating speed of LAN port Entry 10M 100M 3 Duplex Specifies whether the Ethernet interface is being operating in Half or Full duplex mode Entry Half Full 4 802 3 flow control Specifies whether the flow control is enabled or not Entry Enable Disable 5 Packet size 1518 1522 1536 1784 To set VLAN apply menu selection sequence Local gt g
11. Sb ET100BS that include the the data rate of DSL current signal to noise ration SNR the status of DSL and displaying the total number of received transmitted Packets for each LAN port follow the menu entering sequence Local Statue Main Status Device Line Data Rate Port 1 Port 2 Port 3 Port 4 C COT SYNC 4032 kbps LINK DOWN DOWN DOWN RT SYNC 4032 kbps LINK DOWN DOWN DOWN G SHDSL bis LAN EXTENDER Device Type COT Annex Annex A DSL Rate 4032Kbps S N 30 DSL status Synch LAN 1 Rx Tx packet LAN 2 Rx Tx packet LAN 3 Rx Tx packet LAN 4 Rx Tx packet 1 5 Select ltem Enter Accept ESC Escape SPACE Screen Refresh Table 6 1 Display Status Screen Content Item Description 1 Device Type Displays the Device Type which you set SHDTUOSB ET100BS 2 Annex Displays the Annex mode which you set SHDTUOSB ET100BS 3 DSL Rate Displays the DSL Rate 4 S N Displays the current signal to noise ration SNR 5 DSL Status Display the current DSL Status 6 LAN 1 Rx Tx packet Displays the total number of received transmitted Packets through the LAN port 1 7 LAN 2 Rx Tx packet Displays the total number of received transmitted Packets through the LAN port 2 8 LAN 3 RX Tx packet Displays the total number of received transmitted Packets through the LAN port 3 9 LAN 4 packet Displays the total number of received transmitted Packets through the LAN port 4 6 Inventory
12. icators are described in the following table LED Color Status Meaning Steady The device is on UNIT Orange The device is off COT Orange The device is configured to COT mode RT Orange The device is configured to RT mode Steady The device is Sync Status Blinking The link is synchronizing this may take several minutes Off The device is unplugged or disconnected LAN1 Orange Steady Link 1 The LAN connection is successfully established LAN2 Orange Steady Link 2 The LAN connection is successfully established LAN3 Orange Steady Link 3 The LAN connection is successfully established DSL Orange LANA Orange Steady Link 4 The LAN connection is successfully established 8 The rear panel connectors connecting the device to the LAN and xDSL network are illustrated as Power Adapter Console LAN LE below C DSL 1 2 3 4 1 RS 232 PC RJ 45 RJ 11 Phone Line gt xDSL Emulator Terminal VT 100 Figure 1 Rear Panel and Installation LAN Interface RJ 45 port located in SHDTUO3b ET100BSS rear panel meets to IEEE 802 3 or IEEE 802 3u request and supports 10 100 Base Tauto test and half all touble works model operation bridge can provide up to 128 MAC address and MAC address filtration function meets IEEE 802 1d protocol requestment Figures separably shows as following Figure 1 9 RJ 45 pin out
13. icers employees subsidiaries affiliates and distributors harmless against all claims costs damages expenses and reasonable attorney fees arising out of either directly or indirectly any claim of personal injury or death that may be associated with such unintended or unauthorized use even if such claim alleges that CTC Union Technologies was negligent regarding the design or manufacture of said product TRADEMARKS Microsoft is a registered trademark of Microsoft Corp HyperTerminal is a registered trademark of Hilgraeve Inc WARNING This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference in which case the user will be required to correct the interference at his own expense NOTICE 1 The changes or modifications not expressively approved by the party responsible for compliance could void the user s authority to operate the equipment 2 Shielded interface cables and AC power cord if any must be used in order to comply with the emission limits CISPR PUB 22 Class A COMPLIANCE This device complies with EMC directive of the European Commu
14. nity and meets or exceeds the following technical standard EN 55022 Limits and Methods of Measurement of Radio Interference Characteristics of Information Technology Equipment This device complies with CISPR Class A WARNING This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures CE NOTICE Marking by the symbol CE indicates compliance of this equipment to the EMC directive of the European Community Such marking is indicative that this equipment meets or exceeds the following technical standards EN 55022 1994 A1 1995 A2 1997 Class A and EN61000 3 2 1995 EN61000 3 3 1995 and EN50082 1 1997 Union Technologies Ltd Far Eastern Vienna Technology Center Neihu Technology Park No 60 Zhouzi St Neihu Taipei 114 Taiwan Phone 886 2 2659 1021 FAX 886 2 2799 1355 SHDTU03b ET100BS Pair GSHDSL LAN Extender User Manual Version 0 4 November 2009 This manual supports the following models SHDTU03b ET100BS This document is the current official release manual Please check CTC Union s website for any updated manual or contact us by E mail at info ctcu com Please address any comments for improving this manual or to point out omissions or errors to marketing ctcu com Thank you 2008 2009 CTC Union Technologies Co Ltd All Rights Reserved Table of Contents 1 DESCRIPTION
15. rks SHDTU03b ET100BS provides a console port for users to configure the settings and to monitor the DSL connection status SHDTUOSb ET100BS conforms to ITU T G 991 2 the GSHDSL requirements Each SHDTUOSb ET100BS can be configured as either STU C for the central side or STU R for the remote side A pair of SHDTUOSb ET100BS offers a cost effective symmetrical broadband solution for bandwidth hungry applications such as LAN to LAN connection Internet ITU G 991 2 Annex Symmetrical downstream and upstream data rates from 192Kbps to 5 696Mbps Auto Negotiation for 10 100 BaseT Auto MDIX for Auto Ethernet Swap Line Coding 16 TC PAM or 32 TC PAM Line Rate 192K bps 5696 Kbps Standard ITU T G 991 2 Annex Mac Address filtering bridge up to 2K Mac address learning Bridge IEEE 802 1D transport self learning 4 x RJ45 10 100Mbs Ethernet ports 1 x RJ 11 port for GSHDSL bis connection One console port DB 9 Female DC 5 V power input Following Figure shows a point to point application for user interface LAN LAN LAN Figure Ethernet Bridging SHDTUOSb ET100BS SHDSL provide SHDTUOSb ET100BS desktop SHDTUOSb ET100BS desktop include following components SHDTUOSb ET100BS Desktop There are eight LED indicators on the front panel of SHDTU03b ET100BS They show the statuses of the device SHDSL LAN Extender union 4 3 2 1 The functions of LED ind
16. t Configure gt gt VLAN setting gt gt as shown below Mainl Cfg LAN Port Device Type Line CNT Data Rate Port 1 Port 2 Port 3 C COT SYNC 4032 kbps LINK DOWN DOWN RT SYNC 4032 kbps LINK DOWN DOWN G SHDSL bis LAN EXTENDER VLAN Mode Unaware P PSegmented Channel Disable Ingress VID Range Start 0 Ingress VID Range length 0 Port 1 Bandwidth value OKbps Port 2 Bandwidth value OKbps Port 3 Bandwidth value OKbps Port 4 Bandwidth value 1 Unaware 2 Aware Input 1 1 4 Select Item Enter Accept ESC Escape SPACE Screen Refresh Default configuration setup is provided To default the setting follow the steps described below The screen appears when the menu sequence is entered Position the cursor at option 5 Factory Default of Configuration menu and press Enter to restore setting to factory default After setting default value the system prompts you for a Set default succeed Press any key to continue message displayed in reverse video 17 Regardless of STU C STU R SHDTUOSb ET100BSS is provided with 2M byte non volatile flash memory which stores all provisioning parameters of the unit When change are made to the selection option through the Configuration Save sequence the changes must be saved to take effect 5 Performance Monitoring This chapter provides information on the display the status of SHDTUO

Download Pdf Manuals

image

Related Search

Related Contents

PROBLÈME CAUSE PROBABLE SOLUTION Teinte de fond (Tinting)  Pyle Car Stereos User Manual  montagehandleiding / mode d`emploi / montageanleitung  Galva Flash  scheda tecnica  agentMom User`s Manual  APC PML3XS-B surge protector  Husqvarna HU800BBC User's Manual  Using the Timer - Pioneer Europe - Service and Parts Supply website  Manuel d'utilisation  