TeSys U motor starters – open version 1
Contents
1. LUALF1 0 135 On power bases on LAD 90 4 reverser block on parallel link splitter box Limiter cartridge Clip in marker holder 1 The rated peak current for the power sockets AK5 PC is 6 kA When used in association with power bases LUB the prospective short circuit current must not exceed 7 kA 2 Supplied with limiter cartridge 3 These devices make it possible to increase the breaking capacity of the power base 4 Sold in lots of 100 5 The limiter must be mounted on an LUB or LU2B power base The limiter can therefore not be common to several motor starters Phase barrier LU9 SPO must be used m to build a UL 508 Type E certified starter Self Protected Starter m without the phase barrier the starter controller is certified UL 508 m if the starter controller is to be used at an operational voltage of 690 V Description Item Application Mounting Reference Weight kg Phase barrier LUB or LU2B 12 Direct on LU9 SP0 0 030 or 120 terminals LUB or LUB2B 32 L1 L2 L3 or 320 LUALB1 Schneider 1 67 Electric References TeSys motor starters open version TeSys U starter controllers Allows a circuit breaker or a TeSys U starter controller installed in back of an enclosure to be operated from the front of the enclosure The rotary handle can be black or red yellow IP 54 or IP 65 It includes a function for locking the circuit breaker or the starter in the O OFF or O
2. Schneider 4169 Selection Operating characteristics Control units Thermal overload protection TeSys motor starters open version TeSys U starter controllers Control units Standard Advanced Multifunction LUCA LUCB LUCM Lucc LucD Overcurrent protection 14 2 x the setting current 3 to 17 x the setting curre Short circuit protection 14 2 x the max current Protection against phase loss Protection against phase imbalance Earth fault protection equipment protection only Tripping class 5 30 Motor type Single phase and 3 phase Thermal overload test function Overtorque No load running Parameters can be set Parameters can be set Long starting time Reset method Manual Automatic or remote Alarm Possible for each type of fault Indication on front panel of the control unit via remote terminal via PC or via PDA 1 Log function Log of the last 5 trips Number of starts number of trips number of operating hours Monitoring function With function modules 2 Thermal overload alarm Display of main motor parameters on front panel of the control unit via remote terminal via PC or via PDA 1 With module LUF W Thermal overload signalling and manual reset With module LUF DH11 Thermal overload signalling and automatic or remote reset modules LUF DA10
3. 10 or LUF Ve Note Terminals X1 X2 are not isolated from the signalling module power supply For remote resetting use a volt free contact specific to each module to be reset 1N C 4 or 24 250V LUF DA01 0 055 1N O 4 or 24 250V LUF DA10 0 055 Thermal overload alarm Through load shedding this module makes it possible to avoid stoppages in 200 4 operation due to overload tripping Imminent thermal overload tripping is displayed as soon as the thermal state exceeds the threshold of 105 hysteresis 5 Signalling is possible via an LED on the front panel of the module and externally by an N O relay output It can only be used with an advanced control unit from which it takes its power 100 1 5 1 N O or 24 250 V LUF W10 0 055 3 vrs Indication of motor load 3 7 5kW This module provides a signal which is representative of the motor load status 4 12mA 20mA average Ir m average average value of the rms currents in the 3 phases m Ir value of the setting current The value of the signal 4 20 mA corresponds to a load status of 0 to 200 0 to 300 for a single phase load It can be used with an advanced or multifunction control unit Module LUF V2 requires a 24 V external power supply 4 20mA 2 LUF V2 0 050 Characteristics Schemes pages 1 98 and 1 103 page 1 116 Schneider 1 73 Electric
4. 15 0 6 12and32 LUCA X600 0 135 LUCB eece 0 25 0 35 1 4 12and32 LUCA 1Xee 0 135 15 2 2 3 1 25 5 12and32 LUCA 0500 0 135 5 5 5 5 9 3 12 12and 32 LUCA 1200 0 135 75 9 15 45 18 32 LUCA 1800 0 135 15 15 18 5 8 32 32 LUCA 3200 0 135 Pressing the Test button on the front panel simulates tripping on thermal overload Class 10 for 3 phase motors 0 09 0 15 0 66 12and 32 LUCB X6e0e 0 140 0 25 0 35 1 4 12 and 32 LUCB 1Xee 0 140 1 5 22 3 1 25 5 12 and 32 LUCB 0506 0 140 5 5 5 5 g 3 12 12 and 32 LUCB 120e 0 140 7 5 9 15 4 5 18 32 LUCB 1800 0 140 15 15 18 5 8 32 32 LUCB 3200 0 140 Class 10 for single phase motors 0 15 0 6 12 and 32 LUCC X6e0 0 140 0 09 0 35 1 4 12 and 32 LUCC 1Xee 0 140 0 55 1 25 5 12 and 32 LUCC 0500 0 140 LUB e2 LUCA e600 22 3 12 12 and 32 LUCC 1200 0 140 4 4 5 18 32 LUCC 1800 0 140 7 5 8 32 32 LUCC 3200 0 140 Class 20 for 3 phase motors 0 09 0 15 0 6 12and 32 LUCD X6ee 0 140 0 25 0 35 1 4 12 and 32 LUCD 1Xee 0 140 1 5 22 3 1 25 5 12 and 32 LUCD 0506 0 140 5 5 5 5 9 3 12 12 and 32 LUCD 120e 0 140 7 5 9 15 4 5 18 32 LUCD 1800 0 140 15 15 18 5 8 32 32 LUCD 3200 0 140 1 Standard control circuit voltages a BL 2 3 N B A zow ES 4 FU 5 2 Voltage code to be used for a starter controller with communication module 3 d c voltage with
5. Discover TeSys U motor starters open version Starter controller Non reversing power bases LUB 12 LUB 32 Two types of bases are available each in two versions m LUB12 LUB32 Standard power bases 12 A and 32 A versions m Advanced power bases for use in conjunction with LUB120 LUB320 function or communication module 12 A and 32 Aversions DB124035 m Breaking capacity 50 kA at 400 V m Ratings 12 Aor 32 Aat 400 V m Built in auxiliary contacts max operating voltage Up 690 V AC 250 V DC Max current Ith 5A 1 NO 1 NC m Guaranteed continuity of service complete coordination between the protection and control functions to EN 60947 6 2 m Connection by screw clamp terminal Voltage V Rating A Breaking capacity kA Rating A Breaking capacity kA Reference Weight kg LUB12 0 900 LUB 120 LUB 320 Voltage V 440V 500 V 690 V Reference Weight kg g 8 Rating A 12 12 9 LUB2B120 0 865 Breaking 50 10 4 capacity kA Rating A 32 23 21 LUB2B320 0 865 mes Breaking 50 10 9 capacity kA m 3 types of terminal blocks are available providing different types of pole status remote indication and coil control m A cover is always supplied for each terminal block so that the top cavity of the base designed to receive the function modules communication alarm etc can be closed off if necessary Description Reference 3 S Single te
6. Indication of motor load analogue With communication module or via Modbus port on control unit LUCM 2 Starter status ready running fault With module LUF V With any communication module Reset method Parameters can be set via the bus Alarm With modules LUL C031 LUL C033 With module LUL LUL C033 LUL C15 LUL C07 LUL C08 an LUL C15 LUL C07 LUL C08 and Remote reset via the bus LUL C09 thermal overload alarm only LUL C09 Indication of motor load and Modbus port on the control unit alarm possible for all types of fault Fault signalling and differentiation Remote programming and monitoring of all functions With modules LUL C031 LUL C033 Log function LUL C15 LUL C07 LUL C08 and Monitoring function LUL C09 and Modbus port on the control unit HE Built in function EN Function provided with accessory 1 PDA Personal Digital Assistant 2 Mounting possibilities 1 function module or 1 communication module 1 70 Schneider Electric References TeSys motor starters open version TeSys U starter controllers Standard and advanced control units 510913 Extraction and locking handle Test button on advanced control unit only Ir adjustment dial Locking of settings by sealing the transparent cover Sealing of locking handle 1 2 3 4 5 Class 10 for 3 phase motors LUCA eccee eos 0 09 0
7. N position depending on the type of rotary handle by means of up to 3 padlocks with a shank diameter of 4 to 8 mm The extended shaft must be adjusted to the depth of the enclosure The IP54 rotary handle is fixed with a nut 22 to make it easier to assemble rn S z 3 ag a a Description Handle mounting system kit Universal handle Shaft Shaft support plate for deep enclosure Retrofit accessory Laser Square accessory 5 Handle mounting system kit Description Item Reference Weight kg Black handle with error status IP 54 LU9APN21 0 820 Red handle with error status IP 54 LU9APN22 0 820 Red handle without error status IP 65 LU9APN24 0 820 Black handle IP 54 GVAPB54 0 140 Red handle IP 54 GVAPR54 0 140 Red handle IP 65 GVAPR65 0 140 Shaft L 315mm IS GVAPAt 0 110 Shaft support plate for deep enclosure Depth 2 300mm G GVAPK12 0 030 Retrofit accessory G GVAPP01 _ 0 160 Sticker vendu par lot de 10 3 Warning label French GVAPSFR 8 English GVAPSEN gt German GVAPSDE Spanish GVAPSES Chinese GVAPSCN Portuguese GVAPSPT Russian GVAPSRU Italian GVAPSIT 1168 Schneider DB124404 References TeSys motor starters open version TeSys U starter controllers G Electric Description Item Reference Weight kg Handle for mounting inthe MCC 4 LU9AP20 0 586 drawer with fixing kit
8. control link LU9MR1C Reverser block for vertical mounting LU2M BOee Single terminal block for built in auxiliary contacts LU9M1 Terminal block for wired control connection LU9MR1 Reverser block for side mounting LU6M BOece Terminal block with contact status remote indication cable to LU9MRC LULC communication module Q LU9MRL Terminal block with jumper for controlling the coil via LULC communication module One or two letters must be added to the power base reference to identify the control voltage of its coil Example LUB12B 12 A power base with 24 V AC coil control Volts 24 48 72 110 240 BL nN B Zory ES 1 FU 2 1 48 72V 48V 2 110 220 V 110 240 V Scyneider E DB123009 References Covers and for empty cavities are supplied with the basic module 164 Schneider Signalling contacts Non reversing power base Reminder TeSys U is similar to a motor protection circuit breaker and a contactor sharing the same power contacts poles Auxiliary contacts are used to identify the operating mode OPERATION ALLOWED FAULT TRIGGERED STOP OFF They reproduce the status of the rotary handle Operation allowed TRIP OFF They can be similar to the contacts of a conventional circuit breaker open closed circuit breaker OK tripped 2 locations for installing the contacts m in the function module cavi
9. eaker OF contact open closed circuit breaker SD contact circuit breaker OK tripped 2 locations for installing contacts m ina function module cavity plug in box m on the side of the power base side mounting box 1 SD contact NC 95 96 LUA1 C11 0 03 Ce 1 OF contact NO 17 18 1 SD contact NO 97 98 LUA1 C20 0 03 1 OF contact NO 17 18 2 OF contacts NO LUA8E20 0 048 m The auxiliary contacts are used to find the status of the load ON OFF They reproduce the status of the common power contacts NO contacts or the reverse status NC contacts Additional plug in module with 2 auxiliary contacts The contacts built into the power base are used to control the reverser block To remotely indicate the status of the power poles one of the following accessories must be used 2 NO contact 33 34 1 NO contact 43 44 1 NF contact 31 32 2 NF contacts 31 32 and 41 42 LUF N20 LUF N11 LUF N02 Auxiliary contacts are used to find the direction of the load control FORWARD REVERSED They reproduce the status of the reverser block power contacts Auxiliary contact built into the reverser block Generally used to indicate the direction of rotation of a motor 1 reversing contact 82 81 84 Electrical characteristics of the contacts Use of add on and auxiliary contacts or 24 250 V Ith 5A Electric Schneide
10. le to differentiate thermal overload and short circuit faults The short circuit fault can then be signalled via add on contact blocks LUA1 C The module includes two contacts for thermal overload signalling as well as an LED on the front panel To reset the motor starter the operator must use the rotary knob on the power base The module can only be used with an advanced control unit and requires an 24 240 V external power supply 1 N O 1 N C 3 or 24 250V LUF DH11 0 060 Thermal overload signalling and automatic or remote reset These modules make it possible to differentiate thermal overload and short circuit faults The short circuit fault can then be signalled via add on contact blocks LUA1 C The modules include one contact for thermal overload signalling as well as an LED on the front panel Asecond contact terminals Z1 Z2 must be wired in series with terminal A1 of the motor starter In the event of a thermal overload fault this wiring allows motor control to be switched off The rotary knob on the power base will then stay in the ready position Resetting of the motor starter is automatic after the required motor cooling time if terminals X1 X2 are linked by a strap or remote by pulsed closing of a volt free contact connected to terminals X1 X2 These modules can only be used with an advanced control unit and require an 24 240 V external power supply LUB e2 LUCB eecee LUFW
11. maximum ripple of 10 48 72 V 48 V z 110 220 V 110 240 V LUB e2 LUCB eecee Characteristics Schemes pages 1 98 and 1 101 page 1 115 Electric Schneider 1 71 510914 521335 References LUCMeeBL LUB e2 LUCM eeBL A DISPLAY SMALL FONTS _ BIG FONTS 00000909S TeSys motor starters open version TeSys U starter controllers Multifunction control units Extraction and locking handle Built in display window 2 lines 12 characters 4 button keypad 24 V auxiliary power supply Modbus RS485 communication port Connection by RJ45 connector Sealing of locking handle ouhwhd The display window 2 and keypad 3 allow m in configuration mode local configuration of protection functions and alarms m in run mode display of parameter values and events The Modbus communication port 5 is used to connect m an operator terminal m aPC m a Personal Digital Assistant PDA Parameter entry monitoring of parameter values and consultation of logs are carried out m either on the front panel using the built in display window keypad m or via an operator terminal m or via a PC ora PDA with PowerSuite software m or remotely via a Modbus communication bus Programming of the product via the keypad requires a 24 V auxiliary power supply 0 09 0 15 0 6 12 and 32 LUCM X6BL 0 175 0 25 0 35 1 4 12 a
12. nd 32 LUCM 1XBL 0 175 1 5 2 2 3 1 25 5 12 and 32 LUCM 05BL 0 175 5 5 5 5 9 3 12 12 and 32 LUCM 12BL 0 175 7 5 9 15 4 5 18 32 LUCM 18BL 0 175 15 15 18 5 8 32 32 LUCM 32BL 0 175 On CD Rom Multi language 3 LU9 CD1 0 022 This compact Magelis terminal enables the parameters of multifunction control unit LUCM to be read and modified It is supplied pre configured to provide dialogue with 8 TeSys U starter controllers Modbus protocol application pages and alarm pages loaded Starter controller alarm and fault management takes priority Multi language 3 4 lines of 24V XBT NU400 0 150 XBT NU400 20 characters Connects terminal XBT NU400 2 5m SUB D 25 way XBT Z938 0 200 to a multifunction control unit female RJ45 1 Input voltage 24 V with maximum ripple of 10 2 The CD Rom contains user s manuals for the AS Interface and Modbus communication modules multifunction control units and gateway modules as well as the gateway programming software 3 English French German Italian Spanish 4 If a terminal is used with several control units this cable can be connected to a Modbus hub or to T junctions see page 1 95 Characteristics Schemes pages 1 98 and 1 101 pages 1 114 and 1 117 4 72 Schneider Electric 510915 510445 References TeSys motor starters open version TeSys U starter controllers Function modules Thermal overload signalling and manual reset Module LUF DH11 makes it possib
13. r 1 65 References TeSys motor starters open version TeSys U starter controllers Pre wired system for power connections Description Application Pitch Item Soldin Unit Weight mm lots of reference kg Sets of 3 pole 63A 2 tap offs 45 1 GV2G245 0 036 busbars GV2G254 0 038 3 tap offs 45 GV2G345 0 058 1 s 1 s 54 1 GV2G354 0 060 a 4 tap offs 45 1 GV2G445 0 77 54 1 GV2G454 0 085 5 tap offs 54 1 GV2G554 0 100 Protective end cover For unused busbar 5 GV1G10 0 005 outlet Terminal block for 1 GV1G09 0 040 supply to one or more busbar sets The busbar can be screw mounted onto any support Set of 4 pole busbars 3 phase neutral or 3 phase common 3 Number of tap off Item Length Mounting in Reference Weight FA units at 18 mm mm enclosure width kg intervals mm 18 5 452 800 AK5JB144 0 900 Sold in lots of Unit reference Na Number of points used on the busbar current system 2 E AN Ba a AK5PC13 1 AK5PC33 1 AK5PC33L 1 0 060 f ay D 166 Schneider DB123400 DB123999 References TeSys motor starters open version TeSys U starter controllers Limiter blocks and accessories Mounting Unit reference Limiter Direct on power LUALB1 2 disconnector 3 5 base Limiter 3 Separate LA9LB920 Limiter disconnector
14. rminal block for wire remote indication and local coil LU9B N11 control Terminal block with status remote indication cable LU9BN11C to communication module LUF C00 LUL C033 ASILUF C51 local coil control LUSBN11L Terminal block with a cable for controlling the coil via communication module LUL C07 LUL C08 LUL C09 LUL C15 wire remote indication DF510920 DF510922 Ea Schneider DB124037 DF124033 Discover DB124036 Vertical mounting TeSys U motor starters open version Starter controller Non reversing and reversing power bases The reverser power bases non reversing and reversing consist of a combined power base and reverser block and are supplied as an assembled unit They can also be assembled by the customer from units ordered separately m Ratings 12 Aor 32A at 400 V m Built in auxiliary contacts max operating voltage Up 690 V AC 250 V DC Max current Ith 5A 1NO 1 NC m Guaranteed continuity of service complete coordination between the protection and control functions to EN 60947 6 2 m Connection by screw clamp terminal Voltage V Rating A Breaking capacity kA Rating A Breaking capacity kA Reference LU2B12 Weight kg 1 270 LU2 B32 1 270 Side mounting DB124038 Description Reference O12 Aand 32 Abases LUB 12 32 120 Aand 320 A bases LUB 120 320 Prewired reverse
15. ty plug in box m on the side of the power base side mounting box NC 95 96 0 03 1 SD contact 1 OF contact NO 17 18 1 SD contact NO 97 98 LUA1 C20 0 03 1 OF contact NO 17 18 2 OF contacts NO LUA8 E20 0 048 The auxiliary contacts are used to find the status of the load m ON OFF m They reproduce the status of the common power contacts NO contacts or the reverse status NC contacts Auxiliary contacts Generally used for self holding 1 NO contact 13 14 built in 1 NF contact 21 22 built in Module with two additional plug in contacts Used as an extension to the built in contacts for automations signalling 2 NO contacts 33 34 and 43 44 LUFN20 0 05 1 NC contact 31 32 and 1 NO contact 43 44 LUF N11 0 05 2 NF contacts 31 32 and 41 42 LUF N02 0 05 Electrical characteristics of the contacts Use of add on and auxiliary contacts or 24 250 V Ith 5A DB124010 References Covers and for empty cavities are supplied with the basic module Signalling contacts Non reversing and reversing power base The auxiliary contacts are used to identify the load running mode m OPERATION ALLOWED FAULT TRIGGERED STOP OFF They reproduce the status of the rotary handle Operation allowed TRIP OFF They may be similar to the OF Open Closed and SD Fault indicating contacts of a conventional circuit br