RTU32E Datasheet
Contents
1. Firewall functions can be enabled and adjusted via Remote Desktop and the Registry Editor Status and Diagnostic Information The RTU32E provides status information on internal temperature battery and supply voltage level memory and interface board status etc All status information is available via a WorkSuite functions in the PLC application I O Configuration The RTU32E Series is designed to support a wide range of physical IO configurations primarily obtained via the range of Brodersen external IO Expansion modules via a LocalBus RJ45 connector The RTU32E can also be used with 3 party distributed I O via any of the supported drivers e g ModbusTCP or DF1 Integrated I O options The RTU32E is available with 64 I Os 32DI 16RO 12Al 4AO gt Document no 40347 103 RTU32E Data Sheet_14 10 2014 docx RTU32E Data Sheet All digital inputs are also working as 32bit counter inputs 8x are 1kHz and 24x are 100Hz inputs DI 4 7 in section DI1 and section DI3 are 1kHz counter inputs and the rest is 100Hz The counters are read and reset using ZI profile I O in the PLC application I O Expansion options The RTU32E can be used with all existing UCL type Brodersen I O Expansion modules No programming or configuration is required the RTU32E supports automatic I O configuration of Brodersen I O Expansion modules The LocalBus IO communication bus includes power supply for I O Expansion modules The RTU32E can deliv
2. All DI are also working as 32bit counter inputs 8 x 1kHz and 24 x 100Hz DI 4 7 in section DI1 and DI3 are 1kHz counter inputs and rest is 100Hz gt Document no 40347 103 RTU32E Data Sheet_14 10 2014 docx Brodersen A S Islevdalvej 187 DK 2610 Roedovre Denmark Tel 45 45 35 26 27 Fax 45 45 35 26 29 Email sales brodersen com TECHNICAL DESCRIPTION General All the RTU32E software is stored on a removable Compact Flash card During start up the operating system and applications are moved to RAM where it is executed System configuration settings are stored on the Flash Retained variables and buffered events can be stored in non volatile RAM Using the Ethernet network for primary communication provides all the advantages of existing TCP IP networking communication facilities such as FTP HTTP Telnet SNTP etc Fast reliable and secure communication is the main topic Standard networking components software routers switches etc are available to use with the RTU32E In addition serial ports for interfacing to application specific protocols e g Modbus Fieldbus utility protocols network management protocols etc are available Software Basic Setup and Configuration O s la Q BRODERSEN Meiwort Settings RTU32E main settings are configured via the internal webpages as on all other kind of networking devices Default IP 192 168 0 1 The main configuration also includes e LAN netwo
3. Serial Ethernet driver DL DNP3M RL DNP3 Master Serial Ethernet driver DL DNP3SWITS RL DL 118 C37C RL DNP3 WITS Slave Serial Ethernet driver 118 C37 Phasor Client Driver DL DLMS 1 RL DLMS IEC62056 Master driver DL DF1IM RL AB DF1 Master driver DL ETHIPC RL EtherNet IP Scanner driver Our range of drivers is developed all the time ask if your driver is missing or have special requirements Special versions can be delivered as an option Contact us for more details Brodersen A S Islevdalvej 187 DK 2610 Roedovre Denmark Tel 45 45 35 26 27 Fax 45 45 35 26 29 Email sales brodersen com gt CONTENTS INTRODUCTION osc ssenereatiqnaxesusaneheateershenusunevacueenaenoveruenettcons FEATURE ore S Seated nnneoee notivag dean niennaenes saa eadeamonntnnees VERSIONS ORDERING CODES 10 cccccccccceeesesesssssssteeeees Hardware basic version sssssescccccceaeesseeeceeeesaaeseeseees Driver runtime license 0 0 cece eeeeeeeccccccceeeeseeeceeeesaaeneeeeees Wiring details RTU32E ccccccsssseccesesecseseeeseeeseesees TECHNICAL DESCRIPTION ssssseecccecccseeesseeeceessaeeeeeeeees GING i os sae acconsea A E Software Basic Setup and Configuration 00006 Software RTU Configuration and Programming Software Communication DTivers ccccceeceeeeeeeeees 1 0 S ANd Database ccececcccseseccccsseecccsceceneeceeeenesenees 17 OP DW GP erare EE IEC6087
4. 0 5 101 103 104 cceccesesssseeeeeeeeeeeeeeeeseseeees IEC61850 Client and Servelr cccccccsssssseeeeceeseeaeseeeees DNP3 Master Slave Full Suite eee eeeeeceeeeeeeeeeees Data Logging cccccccssccsscccsseceecceecceseceeceasenseeeeeceeeenees Modem Control Dial up Dial in ee eeeeeeeeeeeeeees Real Time Real Time Clock eeecceeeeccceseececeeececeeeeeeeees COM communication for NullModem Radio and LeasedLine modems cccceccceccesceeceeceeeseecseuseeeseeeseneees 3G GPRS Modem controlled directly by RTU32E Power SUDDIY sererererir ansaa ENE EE Other Connectivity Interfaces cccccccceeeeeessseeeeeeees DS CUNY a accagintninacmariectensee enauictinuttana ads yu bncaentieanteanannieenceanseas ean Status and Diagnostic Information cccceseeeeeeeeeeeees I O Configuration cccccccceeeeeeceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees Integrated 1 0 options cccccccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeees I O Expansion OptiOns cccccccceceeseeeeeeeeeeeeeeeeeeeeeeeeeeees RTU hardware monitoring ccccccsssseceecceeseeeeeseeeeeeeees TECHNICAL SPECIFICATIONS ssssceeeeeceeeeeeeeeeeeeeeseeees Basic 32 Bit CPU System ccccsccsseccssccesecesecceeeceseesees Physical Interfaces cccccccccssseceeceeeseceeeeeeeeeeeeseaeeeeees WOO EC AS eden seuntes sues eesea AE Integrated Digital Inputs counter inputs essees Integ
5. 1000 3 2 2000 EN61000 3 3 1995 EN55022 1998 Class A EN55024 1998 EN61000 4 2 1995 EN61000 4 3 1996 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1996 EN61000 4 8 1993 EN61000 4 11 1994 EN 61000 6 2 EMC Immunity Industry EN 60950 Safety requirements for electrical equipment for measurement and control Dry heat IEC 68 2 2 Test Bd Temp 55 C Duration 8h Cold IEC 68 2 1 Test Ad Temp 10 C Duration 8h IEC 68 2 3 Test Ca Temp 40 C RH 95 Duration 8h Climatic Damp heat Vibration IEC 68 2 6 Test Fc sinusoidal Freq 10 150Hz Amp 4g 5 sweeps in 3 orthogonal axes IEC 68 2 27 half sine Acc 15g Pulse time 11msec 3 x 6 shocks Mechanical Shock Protection IP20 Mounting Backplane Housing Metal black anodized Dimensions HxWxD 55x302x192 mm incl mounting bracket and I O connectors Circuit Configuration Digital Inputs Output Relay SPDT gt Document no 40347 103 RTU32E Data Sheet_14 10 2014 docx Brodersen A S Islevdalvej 187 DK 2610 Roedovre Denmark Tel RTU32E Data Sheet Analogue input O z O 100E i V j Circuit Configuration Analogue Jumper In ma Q O O F Q Out V O TR Q O ia O 100E j O Je O gt K OK Jumper In ma Out V rw Analogue Output lout 24V lA amp IB 27V 0 1K VA amp VB 27V GND Interface Overview Vout Right side sS Local Bus COM 4 COM
6. 3 COM 2 MA e 10 30 VDC in 10 45 45 35 26 27 Fax 45 45 35 26 29 Email sales brodersen com Left Side USB1 USB 2 Gaa Eaa LAN 1 LAN 2 a a COM1 VGA FLASH Card Change analogue input type mA DC to V DC Step 1 Unscrew both screws located as figure 1 Step 2 Take lid off Figure 2 gt Figure 2 Document no 40347 103 RTU32E Data Sheet_14 10 2014 docx Step 3 Locate jumpers Figure 3 Step 4 Figure 3 RTU32E Data Sheet Position jumpers for correct input type V or mA Measurement Range for analogue inputs is defined in Webpage default address 192 168 0 1 See possible input variation at page 8 Jumper designation SW300 SW311 SW 300 SW 301 SW 302 SW 303 SW 304 SW 305 SW 306 SW 307 SW 308 SW 309 SW 310 SW 311 ON Channel 0 mA OFF Channel 0 V ON Channel 1 mA OFF Channel 1 V ON Channel 2 mA OFF Channel 2 V ON Channel 3 mA OFF Channel 3 V ON Channel 4 mA OFF Channel 4 V ON Channel 5 mA OFF Channel 5 V ON Channel 6 mA OFF Channel 6 V ON Channel 7 mA OFF Channel 7 V ON Channel 8 mA OFF Channel 8 V ON Channel 9 mA OFF Channel 9 V ON Channel 10 mA OFF Channel 10 V ON Channel 11 mA OFF Channel 11 V Brodersen A S Islevdalvej 187 DK 2610 Roedovre Denmark Tel 45 45 35 26 27 Fax 45 45 35 26 29 Email sales brodersen com 11 gt Change Battery for NV RAM and System c
7. NP3 Master Slave Full Suite DNP3 Drivers with enhanced support for manual data handling and diagnostic are supported DNP3 UK WITS Slave with full connection manager details is also supported Data Logging A special data logging function block is available for logging event based or cyclical data to the flash file system The data logging also supports functions for formatted logs directly exportable to zenon HMI and SCADA software Log files can be downloaded from the RTU32E via FTP Modem Control Dial up Dial in Both dial up and dial in functions via a PSTN ISDN or GSM modem connected to the serial port of the RTU32E are possible when using the PLC modem function It can be used for serial communication e g ModbusRTU and IEC60870 serial protocols Real Time Real Time Clock The real time task is used for the application program execution Time stamps and cyclic execution are also based on the real time clock Time stamps are reported in milliseconds In order to achieve high time accuracy the clock has synchronization options with SNTP and a special clock slave and master function for synchronization from RTU32E to RTU32E COM communication for NullModem Radio and LeasedLine modems The RTU32E has extended data communication features for communication of ModbusRTU serial IEC60870 5 101 etc over serial modems and converters The features cover detailed handshake control with timing of RTS and CTS Brodersen A S Isl
8. RTU32E RTU32E Series Powerful Compact Utility RTU Data Sheet Doc 40347 v1 03 October 14 2014 RSA Soe DOD LS isis ts Ly tte 4 Sr D2 Digtal inputs DO Digital Outputs 001 RTU32E oe Dipta inputs DIO Digital inputs DI Ongita Outputs DOO Analog Inputs AJO Analog 3 4 5 bye a go ss e a ne hiftinin MINIMIN Tetetececess Iaa BRODERSEN simplifying systems gt INTRODUCTION The Brodersen RTU32E controller series is based on a 32 bit platform that provides the RTU PLC with power and leading edge functionality It is provided with an open and adjustable platform with both the power and functionality required to control the most demanding industrial applications Fully equipped with a powerful 1EC61131 PLC web server configuration and real time clock with millisecond resolution it provides you with all the advantages the combination of a very fast PLC and RTU can give you The RTU32E is supplied in a robust metal anodized enclosure and can be used with the wide range of Brodersen I O expansion modules Ethernet and TCP IP are the basic communication and data environments however serial communication interfaces like RS232 and USB also allow the RTU32E to interface to various devices within a network hierarchy FEATURES e 64 channels of on board IO e 32x digital inputs counter inputs e 16x relay outputs e 12x analog inputs e 4x
9. ail sales brodersen com gt Software Communication Drivers The basic drivers and protocols available for the RTU32E are e O drivers for integrated I O and I O Expansion e Modbus RTU Master and Slave e Modbus TCP Client and Server e Modbus ASCII Master and Slave e EC60870 5 101 Master and Slave e EC60870 5 103 Master e EC60870 5 104 Client and Server e EC61850 Client e EC61850 Server incl GOOSE e SNMP Agent driver e PROFI NET Client e DNP3 Master Slave Full Suite e DNP3 UK WITS Slave e EtherNet IP Scanner e DF1 Master e COMLI Master e DLMS IEC62056 Master e 118 C37 Client e Distributed event based binding etc 1 O s and Database Internal I O and expansion I O are managed in an independent database The I O database structure is designed as a multi accessible database The database runs in its own high priority task and provides fast and reliable I O communication The PLC runtime includes a flexible variable database that the user configures with names and data types with no need for fixed or special mapped registers In addition an API for programmers provides access to the database from your own C C or VBA application It can also be used as gateway access to the application program I O Driver The RTU32E I O can be accessed via variable profiles each I O is directly addressed I O diagnostic status information is also available The I O driver supports up to 32 I O expansi
10. analog outputs e Full 1EC61131 IL LD STL FB SFC e Several Communication Protocols Supported e Full Modbus suite e E C60870 5 101 Master Slave e EC60870 5 104 Client Server e IEC60870 5 103 Master e 1E C61850 Client e EC61850 Server with GOOSE e DNP3 Master Slave e WITS DNP3 Slave UKWITS e EtherNet IP Scanner e DF1 Master e ProfiNET Client e RTU Distributed Binding Protocol e SMNP agent for network monitoring alarming etc e Gateway data concentrator functions e Dual Ethernet and 4x COM Interfaces e Support for over 1000 local I Os and 60000 distributed I O e Robust Design for Industrial Applications gt Document no 40347 103 RTU32E Data Sheet_14 10 2014 docx RTU32E Data Sheet e Full remote management with configuration programming and flexible distribution of all levels of software from and to RTUs in remote locations VERSIONS ORDERING CODES Hardware basic version Order code BRE 6410 231B0131 D1 Driver runtime license RTU32E are delivered with a range of standard drivers that includes full Modbus Suite IEC60870 Suite and RTU Distributed Binding protocol For additional drivers a runtime driver license has to be ordered separately The available driver licenses are Order code DL IEC61850S RL DL IEC61850C RL Description IEC61850 Server driver with GOOSE MMS 1EC61850 Client driver DL SNMP RL SNMP Agent driver DL PROFINETC RL ProfiNET Client driver DL DNP3S RL DNP3 Slave
11. er up to 300mA 12VDC for IO modules For I O Module configuration with current requirements that exceeds 300mA you must add I O Additional power supply Please see the I O Expansion selection guide for selecting your I O modules RTU hardware monitoring Parameters like power supply voltage level internal temperature and battery status are available for monitoring in the RTU32E logic application Furthermore memory load status can be monitored Brodersen A S Islevdalvej 187 DK 2610 Roedovre Denmark Tel 45 45 35 26 27 Fax 45 45 35 26 29 Email sales brodersen com TECHNICAL SPECIFICATIONS Basic 32 Bit CPU System CPU Onboard AMD Geode LX800 500 MHz with 128K L2 cache BIOS AWARD 512KB Flash BIOS System chipset AMD Geode LX800 CS 5536 System RAM memory One 200 pin SODIMM socket supports up to 256MB DDR 333 SDRAM Standard configuration is 128MB RAM Non volatile RAM 1MB battery backed RAM Disc SSD Min 128MB removable Compact Flash in Type I II socket Support up to 1GB Real time clock Accuracy Max 30ppm typically 10 12ppm Resolution 1 msec Back up time min 2 years typical 5 years Battery ONLY used if no power is applied Watchdog Level 1 Main CPU Watchdog Level 2 External watchdog controller Physical Interfaces Dual Ethernet 2 x LAN Dual Realtek RTL8101L COMS 4 x RS232 COM1 COM2 full handshake USB 2 x USB 2 0 ports VGA LCD VGA LCD interface PS 2 Single inte
12. evdalvej 187 DK 2610 Roedovre Denmark Tel 45 45 35 26 27 Fax 45 45 35 26 29 Email sales brodersen com gt 3G GPRS Modem controlled directly by RTU32E The RTU32E support Brodersen 3G GPRS modems connected via their USB2 Interface Webpage configuration for the 3G GPRS modems is available to allow automatic handling of connection to a defined APN Alternative and more advanced modem connection handling is supported via dedicated WorkSuite PLC Functions Power supply The RTU32E is available with 10 30 VDC power supply Other Connectivity Interfaces The two USB ports support mouse keyboard Flash disc storage devices USB to LAN converters to extend the number of LAN Ethernet ports 3G GPRS communication devices etc A VGA port for connecting a monitor provides possibility for work with the RTU directly on the OS user interface and use local HMI SCADA via a touch monitor Security Security in access and communication is supported The network servers like Webserver and FTP Server are login and password protected providing multiple access levels with dedicated adjustable rights The RTU32E Series support PPTP and L2TP VPN Clients and can be used to login to VPN Servers VPN is configured via the Webserver and can be controlled from the PLC logic Utility drivers including authentication or encryption features are supported to the extent that is commonly used E g DNP3 drivers all support Secure Authentication V2
13. lock Step 1 Unscrew both screws located as figure 4 Figure 4 Step 2 Take lid off Figure 5 Battery type is 3V CR2450N Renata type NOTES Note 1 Extended operating temperature range can be delivered as an option Please contact us for details Note 2 This data sheet is subject to change without any prior notice gt Document no 40347 103 RTU32E Data Sheet_14 10 2014 docx RTU32E Data Sheet Brodersen A S Islevdalvej 187 DK 2610 Roedovre Denmark Tel 45 45 35 26 27 Fax 45 45 35 26 29 Email sales brodersen com 12
14. on modules and more than 1000 I Os IEC60870 5 101 103 104 Utility protocols IEC60870 5 10x provide full configuration flexibility of almost any interoperability requirements The protocol links are provided as a driver in the application layer data and protocol structures are generated in Structured Text ST This gives full access to set up any Interrogation and ASDU required for the application In addition the driver supports advanced features for gateway functions where for example information in the monitor direction can be moved from one protocol gt Document no 40347 103 RTU32E Data Sheet_14 10 2014 docx RTU32E Data Sheet interface to another without compromising the actual value and original time stamp Also sharing data queues from more ports are possible To simplify and provide fast configuration a RTU32 IEC60870 Configurator tool is available See the IEC60870 Configurator for details IEC61850 Client and Server The RTU32E Series support both IEC61850 Client and Server driver functions The IEC61850 Client is KEMA certified and is fully configured in WorkSuite using the SCL file details The IEC61850 Server driver is configured based on a SCL file The Brodersen WorkSuite includes a SCL file editor where you can import or create your own SCL file by adding the Logical Nodes and Data Attributes you want And after configuring your Server driver you can verify it with the WorkSuite IEC61850 Test Client D
15. rated Relay OUtPUTS ccccccssseecceeeeeceeeeeeseaees Integrated Analogue INDUt cccccesseccecsesseeeeeseeeeeeeees Integrated Analogue OUtPUL cccceeecccssseeeceeeeesaeees SOF ir AEE EN ENE teie ga baclee bas AE EAE gt Document no 40347 103 RTU32E Data Sheet_14 10 2014 docx RTU32E Data Sheet PLC Runtime Details scsccnnesnenccenearannasseantancnenaeeavammetaceaneds 9 PLC Runtime performance sssccccccsseeeceeeeeeeeeeees 9 POWT SUDD Ycee E 9 OME e AE AE A E E N EA 9 Circuit Configuration Digital cccccccccessssseeeeeeeeeeeeees 10 Circuit Configuration Analogue cccccccssseeeeseeeeeeeeeees 10 Interface Overview cccccccssssssseecccesseeeeseeeceessseeaeeeeeeeeeeas 10 Change analogue input type mA DC to V DC 11 Change Battery for NV RAM and System clock 8 12 Brodersen A S Islevdalvej 187 DK 2610 Roedovre Denmark Tel 45 45 35 26 27 Fax 45 45 35 26 29 Email sales brodersen com gt RTU32E Data Sheet Wiring details RTU32E 6 Al 4 Relay out yuta Di e ee Te gta outs DIG ee e 4 ee AY i Ls Al Ansiog Outputs AGT DC supply 10 30 VDC SQ Si 9 Local BUS for I O Modules r BRODERSEN AEF R SGA OF OF mumsa a 2 AO pe kkhk DOQ SVOSSOSIOSVS Y SOESDSSOSSSBDOA ie 2200002 Booo 6 O e d 4 Relay out 4 Relay out 8 98 91819 8 Le 8 DI 8 DI NOTE
16. rature stability Better than 50ppm C 1000hm gt Document no 40347 103 RTU32E Data Sheet_14 10 2014 docx RTU32E Data Sheet Accuracy Vout 25 C 0 2 10 60 C 0 4 Linearity Better than 0 05 Isolation output to output No isolation Software OS Windows Embedded Compact 6 PLC Runtime Details PLC Runtime performance Minimum PLC cycle time gt 1 msec Typical PLC cycle time 3 5 msec Maximum variables 200 000 Scan time internal I O Approx 2 5 msec Scan time external I O Min 6 msec see User Manual for details Power Supply Supply Voltage 10 30VDC Power consumption Max 430W and typical 13W Configuration dependent Isolation Power supply to electronics 1500VDC Max loads LocalBus for supply of I O Expansion modules are 300mA for standard power supply versions General Indicators LEDS Power Indicating power ON System Indicate system status Run Indicate PLC program status I O Indicate status of integrated and expansion I O A C Not used Batt error Internal battery error Com 1 4 Indicate Rx Tx activity on the COM ports DixandDOx Indicate active digital I O Ambient temperature Storage 40 85 C Operation 20 60 C Optional 40 70 C See note 1 Brodersen A S Islevdalvej 187 DK 2610 Roedovre Denmark Tel 45 45 35 26 27 Fax 45 45 35 26 29 Email sales brodersen com gt EMC LVD EN55022 1998 Class A EN6
17. rface for keyboard and mouse RJ45 LocalBus interface for Brodersen I O Expansion modules I O Expansion I O options Expansion I O Expansion I O is possible via the Brodersen I O LocalBus system to all Brodersen I O Expansion modules Supports up to 32 I O Expansion modules of any type Integrated I O 6410 board integrated 32 Digital inputs also works as counter inputs 16 Relay outputs 12 Analogue inputs 4 Analogue outputs gt Document no 40347 103 RTU32E Data Sheet_14 10 2014 docx RTU32E Data Sheet Integrated Digital Inputs counter inputs Inputs Input voltage activated 10 30V DC Input voltage deactivated Max 3V DC Input current 12V DC Typical 3mA 24V DC Typical 6mA Input delay Typical 1ms Isolation 1kV AC Indicators One LED for each digital input Count input frequency 1kHz 8x and 100Hz 24x Integrated Relay Outputs 16 potential free SPDT contacts Output voltage Max 60V DC Output current Max 2A DC resistive Output delay Typical 5ms Relay outputs Lifetime relay Min 100 000 operations at rated load Contact material Gold overlay silver alloy Isolation coils contacts 1kV AC 50Hz 1 min IEC255 5 Indicators One LED for each output yellow indicating active output Integrated Analogue Input 12 multiplexed analogue channels with solid state multiplexer Inputs Input configuration Differential flying capacitor type Inp
18. rk settings IP subnet gateway DNS etc e Basic PLC mode settings e Built in I O settings actual configuration e Hardware Overview Status on I Os e Modem VPN Settings e Security e Real time clock settings SNTP e SNMP agent e Redundancy e Remote secure protocols e HMI e Online status of physical I O gt Document no 40347 103 RTU32E Data Sheet_14 10 2014 docx RTU32E Data Sheet The main page contains information about the software version build type installed drivers and actual connection data Software RTU Configuration and Programming The Brodersen WorkSuite fully supports EN IEC61131 and is used for creating and compiling PLC runtime projects in the RTU32E WorkSuite supports programming languages such as Structured Text ST Function Block FB Ladder LD Instruction List IL and Sequential Function Chart SFC The RTU32E supports cold restart hot restart and on line changes Brodersen WorkSuite is also a powerful tool for complete system design and programming providing unique functions for event based communication The Global Binding Editor makes it possible to publish and subscribe variables in a large network with minimal communication load The events are time stamped Programming debugging and upload and download of application programs can be done remotely via Ethernet or RS232 Brodersen A S Islevdalvej 187 DK 2610 Roedovre Denmark Tel 45 45 35 26 27 Fax 45 45 35 26 29 Em
19. ut measuring ranges 0 10V 0 5V 5 5V 10 10V 0 2V 0 20mA 0 4 2V 4 20mA Selection between these ranges shall be done on Web page and jumper setting Default range settings are 4 20mA with jumpers set Resolution 14 bit 0 16383 Impedance Voltage 1M Ohm Current 100 Ohm 0 25 Brodersen A S Islevdalvej 187 DK 2610 Roedovre Denmark Tel 45 45 35 26 27 Fax 45 45 35 26 29 Email sales brodersen com gt Absolute maximum ratings Input voltage Input current a 15V DC 30mA DC Update time Better than 350 msec Measuring accuracy 25 C 0 1 typically 0 05 10 55 C 0 3 typically 0 1 Linearity Better than 0 05 Temperature stability Better than 50ppm C typical Common mode voltage Max 80V DC Common mode rejection ratio Min 72dB Series mode rejection Min 36dB 50 120Hz Isolation input to input 500V Integrated Analogue Output Outputs 4 sourced analogue channels Output ranges O 10V 0 5V 5 5V 10 10V 0 20mA 4 20mA Selection between these ranges are done in web page Resolution 14 bit 0 16383 Absolute maximum ratings lout Output voltage 27V DC Load 1kOhm Output current 25mA DC Vout Output voltage 15V Load 1kOhm Update time Better than 100 msec 25 C 1000hm 0 2 10 60C 1000hm 0 4 Accuracy lout Linearity Better than 0 05 Leakage current Max 20 uA typically 5uA Tempe