Home
OPC Portal Server User Guide OPC Portal Server User Guide
Contents
1. Launch and Activation Permissions le Use Default C Customize E Access Permissions f Use Default C Customize l d In the Launch and Activation Permissions select Use Default e Similarly in the Access Permissions select Use Default f Click OK g Reboot the computer The configuration of DCOM is complete Document 553701 2 11 ICSTT RM407_EN_P Issue 03 Chapter 3 Setting Up This chapter explains how to configure the OPC Portal Server to work with your project In This Chapter Setting the OPC Portal Server to Match Your AADvance Workbench a A 3 Build or Rebuild a Project c omooonmommmmmmmo 3 Manually Configure the OPC Portal Server oooooocicicnocicicnonococconnnonononoonononos 3 3 Setting the OPC Portal Server to Match Your AADvance Workbench Project The configuration of the OPC Portal Server needs to accurately reflect the contents of the application which is running on the AADvance controllers When you build or rebuild a project the AADvance Workbench application automatically launches the OPC Server Configuration Wizard to prompt you to configure the OPC Portal Server You may need to configure the OPC Portal Server to suit an existing AADvance Workbench project which is already built You can run the wizard manually to do this Build or Rebuild a Project Note Before you begin this task you must have installed the
2. 2 6 Document 553701 ICSTT RM407_EN_P Issue 03 gt Goto the Launch and Activation Permissions area click Edit Default 9 The Launch Permission dialog box opens Launch Permission Default Security Group or user names E Administrators DALHAR T Administrators ti Everyone ER INTERACTIVE EE SYSTEM Do the following a Add the group ANONYMOUS LOGON you created earlier and allow all permissions Local Launch Remote Launch Local Activation and Remote Activation b Similarly add the group Everyone and allow all options c Click OK 10 Return to the COM Security tab of the My Computer Properties dialog box My Computer Properties Default Properties COM Security General Options Default Protocol MS OTE Access Permissions ou may edit who iz allowed default access to applications ou may also set limits on applications that determine their own permissions Edit Default Gotothe Access Permissions area click Edit Limits Document 553701 2 7 ICSTT RM407_EN_P Issue 03 OPC Portal Server User Guide AADvance Controller II The Access Permission window opens Access Permission Security Limits Group or user names er ANONYMOUS LOGON Pennissions for ANONYMOUS LOGON Local Access Remote Access Do the following a Set the group ANONYMOUS LOGON to allow Local Access and Remote Access b Similarly set
3. OPC clients connect to the server using Microsoft COM or if located on a different host Distributed COM DCOM The OPC Portal Server and the controller communicate using a secure protocol which is transparent to OPC clients This protocol is proprietary to ICS Triplex The OPC Portal Server runs as a Windows service This means that it has no application window does not appear on the task bar and is not started using an icon The server will automatically start on boot up and continue to run without needing a user to log in This manual describes the use of the OPC Portal Server under Microsoft Windows XP Professional with Service Pack 2 Vista Windows 7 or Server 3 32 bit or 64 bit Note The OPC Portal Server conforms to version 1 10 of the Alarms and Events Standard published by the OPC Foundation Document 553701 ICSTT RM407_EN_P Issue 03 OPC Data Access Interface The OPC Data Access interface allows multiple Data Access clients to access any AADvance controller tag A Data Access client can do the following gt Query the value of a specific tag gt Subscribe to a tag to receive updates when the value of that tag changes gt Change the value of a tag in an AADvance controller The OPC Portal Server conforms to version 3 00 of the Data Access Custom Interface Standard published by the OPC Foundation OPC Alarm and Event Interface The OPC Alarm and Event interface provides a source of alarm and event infor
4. Note Before you begin this task you must have a Windows administrator account and you must have installed the OPC Core Components Redistributable To install the OPC Portal Server do the following Log onto Windows using an administrator account 2 Insert the distribution CD and wait a few seconds for the disc to autorun gt The OPC Products Installer window opens gt If the disk does not start Windows settings can cause this locate and select the file named autorun exe 3 Click to install the OPC Portal Server gt The AADvance Products Installer starts 4 Review and accept the Licence Agreement step click Next 5 At the Select Features step accept the default components click Next 6 At the Review installation settings step click Next 7 Click Install to start the installation process 8 The installer offers the opportunity to place a shortcut to the product folder on your desktop click Yes gt The installer will complete its tasks after a few seconds gt You have now installed the OPC Portal Server 9 Accept the default item Yes I want to restart my computer now click Finish 10 Wait for Windows to restart and then log on using an administrator account Document 553701 2 3 ICSTT RM407_EN_P Issue 03 OPC Portal Server User Guide AADvance Controller Using a Client on a Separate Computer You can use the OPC Portal Server in a system with the clients and the server on sep
5. 7 Document 553701 1 3 ICSTT RM407_EN_P Issue 03 OPC Portal Server User Guide AADvance Controller SOE Condition_TIC_ 0 Unknown_Code 8 SOE Condition_Array VA of index Latest resource CRC Value of Index Bounds 9 variable SOE Condition_Start 10 Original Latest resource CRC Resource compilation resource CRC SOE_Condition_Resource_Sto Original Latest resource CRC Resource compilation p II resource CRC SOE_ Condition_Online_Chang Original Latest resource CRC Resource compilation e 12 resource CRC SOE Condition_Online_Chang Original Latest resource CRC Resource compilation e 12 resource CRC Table 1 SOE Variables and there Meaning Condition Remarks SOE_Condition_Falling 0 A BOOLEAN has transitioned from a True to a False SOE_Condition_Rising 1 A BOOLEAN has transitioned from a False to a True SOE Condition Unlock 2 A locked variable has been unlocked SOE_Condition_Lock 3 A variable has been locked OE_Condition_Force 4 A variable has been forced SOE Condition Div_By_Zero 5 The application has performed a divide by zero Note there is a special function block the application can use to monitor this condition SOE Condition Max_ Pou_exe_ Time Not implemented the watchdog terminates the 6 application in this case SOE_Condition_Call_ Depth 7 A function has called a function that has called a function etc to a depth greater than that which can be managed by the target
6. Document 553701 ICSTT RM407_EN_P Issue 03 Chapter 4 Using the OPC Portal Server This chapter provides notes on using the OPC Portal Server These notes supplement the specific instructions for your OPC clients In This Chapter Identifying the OPC Portal Server uessssesesssesesessenesnsnnnnnnsnnnnnnnnnnnnnnnnen 4 Running the OPC Portal Server susnesesesesesesnenenesnenenennsnenennsnenenesnenenennenenene 4 Managing the OPC Portal Server from a Command Prompt 4 2 Manage the OPC Portal Server from the Windows Services Management CONS tii danes 4 3 Managing the OPC Portal Server from the Windows Task Manager 4 3 Identifying the OPC Portal Server OPC clients that allow browsing of the available servers see the OPC Portal Server as ICSTriplexOPCServer Running the OPC Portal Server The OPC Portal Server starts automatically on boot up However you can stop and restart the server manually or through a batch file if necessary Document 553701 4 1 ICSTT RM407_EN_P Issue 03 OPC Portal Server User Guide AADvance Controller Managing the OPC Portal Server from a Command Prompt You can start and stop the OPC Portal Server by issuing commands in a Command Prompt window or from a batch file Note use cmd exe not command exe The recommended command is net C gt net stop icstriplexopcserver The ICSTriplexOPCServer service is stopping The ICSTriplexOPCServer service w
7. SOE Condition _TIC_Unknown_Code The resource has detected an instruction code that is 8 not valid SOE Condition _Array_ Bounds 9 An application has attempted to access an arry element outside of the bounds of the array SOE_Condition_Resource_Start 10 A resource has started SOE_Condition_Stop 11 A resource has stopped SOE Condition _Online_Change 12 A successful online update has been performed SOE_Condition_Online_Change 12 A new application was downloaded to the resource 1 4 Document 553701 ICSTT RM407_EN_P Issue 03 Note The OPC Portal Server generates events only for variables that you have configured for Sequence of Event updates within the AADvance Workbench application Document 553701 ICSTT RM407_EN_P Issue 03 1 5 Chapter 2 Software Installation This chapter describes the installation process for the OPC Portal Server Note You can install the OPC Portal Server as an upgrade from a previously installed version or as a new installation In This Chapter Preparing to Install the OPC Portal Server oooocicicicnociciciononoccconnonoronnrnononos 2 Set Administrator Privileges to Start a Service oooococoocicicnonocicnnncncnononornos 2 Synchronizing the Real time Clock eesssssecseseceesseeceeeececeseeesceeeeesceeeeees 2 2 Install the OPC Core Components Redistributable o oo 2 2 Install the OPC Portal Server esssscssssscsssssscsssssscsceessssessesscsssessc
8. AADvance The Next Step in Automation AADvance Controller OPC Portal Server User Guide Issue 03 DOCUMENT 553701 ICSTT RM407_EN_P SEIN THINK o Rockwell SOLVE icstriplex Automation OPC Portal Server User Guide AADvance Controller This page intentionally left blank Document 553701 ICSTT RM407_EN_P Issue 03 Notice In no event will Rockwell Automation be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment The examples given in this manual are included solely for illustrative purposes Because of the many variables and requirements associated with any particular installation Rockwell Automation does not assume responsibility or reliability for actual use based on the examples and diagrams No patent liability is assumed by Rockwell Automation with respect to use of information circuits equipment or software described in this manual Reproduction of this manual in whole or in part without written permission of Rockwell Automation is prohibited All trademarks are acknowledged Disclaimer It is not intended that the information in this publication covers every possible detail about the construction operation or maintenance of a control system installation You should refer to your own or supplied system safety manual installation instructions and operator maintenance manuals Revision and Updating Policy This document is ba
9. C Portal Server In This Chapter The OPC Portal Server ae OPC Data Access Interface cccscccsscsssccssscccsssscsccsssccessssccessesscceseseccees 3 OPC Alarm and Event Interface ooooonnocccnooncccononnccnnonocononnnccnononccnnnonnccnnon 3 The OPC Portal Server The OPC Portal Server is a windows based application that allows OPC compatible clients such as HMIs and SCADA systems to connect to one or more AADvance controllers to access process data A PC implementation of SNCP supports 50 connections of which the OPC server uses 2 per controller gt The current OPC implementation supports 6 controllers without significant degradation of performance however more than that number might degrade the service The OPC Portal Server supports gt OPC Data Access often known as DA which provides real time data from AADvance controllers to OPC clients gt OPC Alarms and Events often known as AE which provides time stamped alarm and event notifications A typical arrangement is shown in the illustration Document 553701 1 1 ICSTT RM407_EN_P Issue 03 OPC Portal Server User Guide AADvance Controller 1 2 F i i i OPC re i l Distributed control i Supervisory Control and workstation i ar Clients system Data Acquisition system i I 1 l HMI Workbench a es Sa ane 9300 9110 Processor A A a
10. Now displays a list of all available users Synchronizing the Real time Clock The OPC Data Access data type includes a time stamp which the OPC Portal Server derives from the real time clock of the computer which is running the OPC Portal Server If you use Data Access you may wish to synchronize the clock with the clocks of the AADvance controllers Install the OPC Core Components Redistributable Note Before you begin this task you must have a Windows administrator account To install the OPC Core Components Redistributable do the following Log onto Windows using an administrator account 2 Insert the distribution CD gt The OPC Products Installer window opens gt If the disk does not start Windows settings can cause this locate and select the file named autorun exe 3 Click to install the OPC Core Components Redistributable gt The OPC Core Components Redistributable Setup Wizard starts 4 Click Next 22 Document 553701 ICSTT RM407_EN_P Issue 03 5 At the Select Installation Folder step do the following a Accept the default folder for the installation b Select the radio button for Everyone c Click Next 6 Review and accept the Licence Agreement click Next 7 At Confirm Installation click Next to start the installation 8 When Installation Complete appears click Close You have now installed the OPC Core Components Redistributable Install the OPC Portal Server
11. OPC Portal Server and rebooted the computer The Workbench application prompts you to configure the OPC Portal Server when you build or rebuild a project Do the following Click the Build or Rebuild button within the AADvance Workbench application A Start ConfigGen Tool message appears W Start ConfigGen Tool Do you want bo Start Config en Tool which will generate ML file For OPC Server Bo Don t Ask Again 2 You can suppress this message for your current AADvance Workbench session To do this put a tick in the box labelled Don t Ask Again Document 553701 3 1 ICSTT RM407_EN_P Issue 03 OPC Portal Server User Guide AADvance Controller 3 4 5 6 7 8 9 The message will reappear the next time you start the AADvance Workbench application and build or rebuild a project Click Yes gt The OPC Server configuration wizard starts gt The wizard provides a series of screens Work through the screens in sequence The Source ISaGRAF Project step identifes your AADvance Workbench project file click Next At the Include ISaGRAF Internal Variables step select the box Generate OPC items for ISaGRAF internal variables click Next At the Include Server Constants step put a tick in the box labelled Include automatic Server Constants gt The wizard populates the list of server constants automatically Click Next At the Include Server Functions step select the
12. all configure and use the OPC User Manual Server for an AADvance Controller Document 553701 Gl ICSTT RM407_EN_P Issue 03 OPC Portal Server User Guide AADvance Controller PFH avg and PFDavg Data This document contains the PFH and PFD Data for the AADvance Controller It includes examples on how to calculate the final figures for different controller configurations The data supports the recommendations in the AADvance Safety Manual Doc No 553630 Regional Offices Rockwell Automation Oil and Gas Resources are available in Regional Offices worldwide Rockwell Automation Rockwell Automation Rockwell Automation 4325 West Sam Houston Hall Road Millenium House Parkway North Suite Maldon Campus 100 Essex Aberdeen Science amp Tech Houston CM9 4LA Park Texas 77043 1219 England UK Balgownie Road Bridge of USA Don Scotland UK Tel 1 713 353 2400 Tel 44 1621 854444 44 1224 227 780 Fax 1 713 353 2401 Fax 44 1621 851531 Rockwell Automation Abu Dhabi Dubai No 2 Corporation Road 903 Bin Hamoodah Building Silvertech Middle East F04 01 to 03 9th Floor FZCO Corporation Place Khalifa Street PO Box 17910 Singapore 618494 Abu Dhabi Jebel Ali Free Zone UAE Dubai UAE Tel 65 6622 4888 971 2 627 6763 9714 883 7070 Fax 65 6622 4884 Internet http www rockwellautomation com icstriplex Technical support icstsupport ra rockwell com Sales enquiries sales icstriplex com 5 2 Docume
13. anager as ICSTriplex_OPC_Server exe in the Processes tab Document 553701 4 3 ICSTT RM407_EN_P Issue 03 Chapter 5 Additional Resources For more information about the AADvance system refer to the associated Rockwell Automation technical manuals shown in this document map Safety Manual 553630 Solutions System Build Configuration Troubleshooting Handbook Manual Guide and Maintenance Manual 553631 553632 553633 553634 Publication Purpose and Scope Safety Manual This technical manual defines how to safely apply AADvance controllers for a Safety Instrumented Function lt sets out standards which are mandatory and makes recommendations to ensure that installations meet their required safety integrity level Solutions Handbook This technical manual describes the features performance and functionality of the AADvance controller and systems It sets out some guidelines on how to specify a system to meet your application requirements System Build Manual This technical manual describes how to assemble a system switch on and validate the operation of a your system Configuration Guide This manual defines how to configure an AADvance controller using the AADvance Workbench to meet your system and application requirements Troubleshooting and This technical manual describes how to maintain troubleshoot and Maintenance Manual _ repair an AADvance Controller OPC Portal Server This manual describes how to inst
14. arate computers To do this you need to set up the Distributed COM DCOM protocol on each computer This will enable the remote clients to communicate with the OPC Portal Server Note You must use the same user name and password for the Windows accounts on each computer Configure DCOM for Windows XP Note Before you begin this task you must have a Windows administrator account To configure DCOM do the following Log onto Windows using an administrator account 2 Open the Windows Control Panel and navigate to Administrative Tools Select Component Services gt The Component Services applet starts 3 Within the Component Services applet navigate to Component Services gt Computers gt My Computer ie Component Services amp e EJ a File Action View Window Help 37 ka x E da gt a e EE ie ff woot o My Computer 4 objeck s E a Component Services EY Computers H E My Computer H Event viewer Local Say Services Local COM DCOM Config Applications Distributed Running Transacti Processes 2 4 Document 553701 ICSTT RM407_EN_P Issue 03 4 Right click on My Computer to display the My Computer Properties select the Default Properties tab My Computer Properties Default Protocols MSBTE COM Securit General Options Default Properties W Enable Distributed COM on this computer OS 5 Do the following gt Puta tick in the box labelled Enable Distribut
15. as stopped successfully C gt net start icstriplexopcserver The ICSTriplexOPCServer service is starting The ICSTriplexOPCServer service was started successfully If Service Control is installed you can use the sc command C gt sc stop icstriplexopcserver SERVICE NAME icstriplexopcserver TYPE 10 WIN32_OWN_PROCESS STATE 3 STOP_PENDING STOPPABLE NOT_PAUSABLE ACCEPTS_SHUTDOWN WIN32_EXIT_CODE 0 0x0 SERVICE _EXIT_CODE 0 0x0 CHECKPOINT 0x0 WAIT_HINT 0x1388 There are two related commands C gt sc query icstriplexopcserver reports whether the service is running C gt sc start icstriplexopcserver 4 2 Document 553701 ICSTT RM407_EN_P Issue 03 Manage the OPC Portal Server from the Windows Services Management Console You can start and stop the OPC Portal Server from the Windows services management console To use the Windows services management console to control the server do the following 1 Open the Windows Control Panel and navigate to Administrative Tools Select Services gt The services management console displays a list of all available Windows services 2 Scroll down the list of services to locate the item ICSTriplexOPCServer 3 Use the console to start stop or restart the service Managing the OPC Portal Server from the Windows Task Manager You can start and stop the OPC Portal Server from the Windows Task Manager The OPC Portal Server is visible in the Windows Task M
16. box Include automatic Server Functions The wizard populates the list of server functions automatically Click Next 10 At the Where to place the generated configuration file step do the following a If you wish to change the disk location of the file for example to specify a network drive use the Destination Folder to specify the location Otherwise leave this field blank to use the default location b If you wish the OPC Portal Server to ignore the new file for example because the server is supporting another project remove the tick in the box labelled Update Otherwise make sure there is a tick in the box labelled Update I1 Click Next 2 The wizard generates the configuration file Document 553701 ICSTT RM407_EN_P Issue 03 12 Configuration File Generation Complete The final step shows the contents of the configuration file click Restart OPC Service Now 13 Click Finish Configuration File Generation Complete Congratulations you have successfully completed the OPC Server Configuration File Wizard The application variable OPC items generated are shown below DFile Yv 00000004 SYSYA_RESNAME String Messag A __ _ TA 00000108 SYSVA CYOLEDATE Time E vA 0000010 __S SVA_TCYCYCTIME Tine va 00000110 __S SVA_TCYCURRENT Tine TA 00000114 SYSVA TOYMAXIMUM Tine va 00000118 SYSVA TCYOVERELOU Double Intege YA 0000011C SYSVA SCANCHT Doub
17. ed COM on this computer Set the Default Authentication Level to None gt Set the Default Impersonation Level to Identify 6 Select the COM Security tab My Computer Properties General Options Default Properties Default Protocols MSDTE COM Security Access Permissions You may edit who is allowed default access to applications You may also set limits on applications that determine their own permissions Edit Limits gt Goto the Access Permissions area click Edit Default Document 553701 2 5 ICSTT RM407_EN_P Issue 03 OPC Portal Server User Guide AADvance Controller 7 The Access Permission dialog box opens Access Permission PT ANONYMOUS LOGON f Everyone EE SYSTEM Permissions for ANONYMOUS LOGON Al Deny Do the following a Adda group named ANONYMOUS LOGON and allow Local Access and Remote Access b Similarly add a group named Everyone and allow Local Access and Remote Access c Click OK to close the Access Permission dialog box 8 Return to the COM Security tab of the My Computer Properties dialog box My Computer Properties General Options Default Properties Default Protocols MSDTE COM Security Launch and Activation Permissions You may edit who i allowed by default to launch applications or activate objects ou may also set limite on applications that determine their own permissions Edit Limits
18. eessceeeeeeeseees 2 2 Install the OPC Core Components Redistributable 00 0 essssssseceseeeececeecesscessececcscsceeesesceeeeeeceeeeeees 2 2 Install the OPC Portal SOS 2 3 Using a Client on a Separate Computer uuesessssssesssssennsnsnnnnnnnnsnnnnnnnnnnnnnsnennsnsnennsssnennsnssnnnnnsnesssnnsnnnsnnsnnnnn 2 4 Configure DCOM for Windows XP an a a a ia 2 4 Chapter 3 A E E A 3 1 Setting the OPC Portal Server to Match Your AADvance Workbench Project 3 Build or Rebuild a Project sea siii 3 Manually Configure the OPC Portal Server esssssscscesececessssssescscscescscsceesscscscessscceseacceaesceeeeeaeeeeeees 3 3 Chapter 4 Using the OPC Portal Server cssssssssssssssccccccccccccsscccssssssssscscscecees 4 Identifying the OPC Portal Server esesessenesosnenesnsnenennonenenennenenennenenennenenennsnnsenennenensnnenensnsnenensnenesesnenenennen 4 Running the OPC Portal Server iii 4 Managing the OPC Portal Server from a Command Prompt ccsssssscecesseceeescssecescceeesesceeeeeeceeeeeees 4 2 Manage the OPC Portal Server from the Windows Services Management Console 4 3 Managing the OPC Portal Server from the Windows Task Manager ccssssssssececeseseseceseeeseeeees 4 3 Chapter 5 Additional Resources arial 5 1 FS EIEE CS ee ee ee Reg 5 2 viii Document 553701 ICSTT RM407_EN_P Issue 03 Chapter 1 Introduction This chapter provides a brief overview of OPC and the ICS Triplex OP
19. ersesees 2 3 Using a Client on a Separate Computer uussessssssesssnssenssnnsnnnnnnnnnnnnnnnnsnsnnnen 2 4 Preparing to Install the OPC Portal Server You need these items to install the OPC Portal Server Distribution CD The installation process requires that you complete a number of tasks in the following order Make sure you have a Windows administrator account with the privilege to start a service 2 Synchronize the real time clock 3 Install the OPC Core Components Redistributable 4 Install the OPC Portal Server 5 Set up Distributed COM DCOM if required Set Administrator Privileges to Start a Service To ensure that a user of Windows XP can start a service do the following 1 Open the Windows Control Panel and navigate to Administrative Tools Select Local Security Policy The Security Settings dialog box opens 2 Select Local Policies gt User Rights Assignment 3 Open the item Log on as a service Document 553701 2 1 ICSTT RM407_EN_P Issue 03 OPC Portal Server User Guide AADvance Controller gt The Properties window shows the users that are allowed to start a service Log on as a service Properties Local Securty Setting Log on as a service Ej 5 1 5 21 2021081337 4033397 366 137 26939 1003 Add User or Group 4 Ifthe chosen user does not appear in the list add the user by clicking Add user or group Clicking Advanced and Find
20. ions automatically 9 Click Next 10 At the Where to place the generated configuration file step do the following a If you wish to change the disk location of the file for example to specify a network drive use the Destination Folder to specify the location Otherwise leave this field blank to use the default location b If you wish the OPC Portal Server to ignore the new file for example because the server is supporting another project remove the tick in the box labelled Update Otherwise make sure there is a tick in the box labelled Update II Click Next The wizard generates the configuration file 12 Configuration File Generation Complete The final step shows the contents of the configuration file click Restart OPC Service Now 13 Click Finish Configuration File Generation Complete Congratulations you have successfully completed the OPC Server Configuration File Wizard The application variable OPC items generated are shown below DFile TA 00000004 SYSVA RESNAME String Messag A TA 00000108 SYSVA CYCLEDATE Time TA 0000010C __S SVA_TCYCYCTIME Tine va 00000110 __S SVA_TCYCURRENT Tine TA 00000114 SYSVA TOYMAXIMUM Tine va 00000118 SYSVA TCYOVERFLOW Double Intege vAa 00000110 SYSVA SCANCHT Double Intege Fa nananien F 1 OYOVA CXCLECHT Tiauhle Tnteoe Do you want to Restart the OPC Server Service on this machine now or Finish Finish
21. le Intege Fa nananin F 1 OYOVA C CTLRCHT fnmhlre e e gt Do you want bo Restart the OPC Server Service on this machine now or Finish Finish Manually Configure the OPC Portal Server Note Before you begin this task you must have installed the OPC Portal Server and rebooted the computer To configure the OPC Portal Server manually without building or rebuilding a project do the following 2 3 4 5 6 7 8 Document 553701 Open the Tools menu within the AADvance Workbench application and click ConfigGenTool The OPC Server configuration wizard starts gt The wizard provides a series of screens Work through the screens in sequence At the Source ISaGRAF Project Selection step click Browse and locate your AADvance Workbench project file If the ISaGRAF file has password protection complete the Password field Click Next At the Include ISaGRAF Internal Variables step select the box Generate OPC items for ISaGRAF internal variables click Next At the Include Server Constants step put a tick in the box labelled Include automatic Server Constants gt The wizard populates the list of server constants automatically Click Next At the Include Server Functions step select the box Include automatic Server Functions 3 3 ICSTT RM407_EN_P Issue 03 OPC Portal Server User Guide AADvance Controller 3 4 gt The wizard populates the list of server funct
22. mation to clients Each time an event occurs the OPC Portal Server informs the client of the event The information provided by the OPC Portal Server includes the tag name value and time which the client can use for example to trigger an alarm or record in an event log OPC Alarm and Event clients subscribe to the server by controller name and receive all events originating from subscribed controllers SOE Conditions Reported BY the OPC Server Condition Ref Variable VA Ref Variable Value SOE_Condition_Falling 0 VA of SOE ed VA of reference Value of reference Varaible variable or VA of variable or value of SOE ed variable if no variable being SOE ed reference variable if no reference configured variable configured SOE_Condition_Rising 1 VA SOE ed VA of reference Value of reference variable or VA of variable or value of SOE ed variable if no variable being SOE ed reference variable if no reference configured configured SOE Condition Unlock 2 VA of Variable VA of Variable being Value of Variable being being unlocked unlocked unlocked SOE_Condition_Lock 3 VA of Variable VA of Variable being Value of Variable being being locked locked locked SOE_Condition_Force 4 VA of Variable VA of Variable being Value of Variable being being forced forced forced SOE Condition _Div_By Zero VA of divisor POU number 0 5 value that is 0 SOE Condition _Max_ 0 Pou_exe_Time 6 0 0 0 SOE_Condition_Call_ Depth
23. ngs and Cautions WARNING ELECTRICAL ARCS AND EXPLOSION RISK IN HAZARDOUS WARNING CAUTION CAUTION AREAS If you connect or disconnect wiring modules or communications cabling while power is applied an electrical arc can occur This could cause an explosion in hazardous location installations Do not remove wiring fuses modules or communications cabling while circuit is energized unless area is known to be non hazardous Failure to follow these instructions may result in personal injury MAINTENANCE Maintenance must be carried out by people who are experienced in working on electronic equipment and in particular safety related systems They should have knowledge and experience of local operating and safety standards Failure to follow these recommendations may result in situations that can lead system damage and even personal injury RADIO FREQUENCY INTERFERENCE Most electronic equipment is influenced by Radio Frequency Interference Caution should be exercised with regard to the use of portable communications equipment around such equipment Signs should be posted in the vicinity of the equipment cautioning against the use of portable communications equipment HEAT DISSIPATION AND ENCLOSURE POSITION System and field power consumption by modules and termination assemblies is dissipated as heat You should consider this heat dissipation on the design and positioning of your enclosure e g enclosures exposed to c
24. nt 553701 ICSTT RM407_EN_P Issue 03
25. ontinuous sunlight will have a higher internal temperature that could affect the operating temperature of the modules Modules operating at the extremes of the temperature band for a continuous period can have a reduced reliability Document 553701 ICSTT RM407_EN_P Issue 03 OPC Portal Server User Guide AADvance Controller Foreword This technical manual describes how to install and use the OPC Portal Server for an AADvance controller It shows how to install and configure the server and how to use it with a system Who Should Use this Manual This technical manual is for qualified control system engineers who install commission or operate OPC clients or the AADvance controller vi Document 553701 ICSTT RM407_EN_P Issue 03 OPC Portal Server User Guide AADvance Controller Contents Chapter 1 A A l 1 The OPC Fortal SO Oscos otitis OPC Data Access Mtra iio 3 OPC Alarm and Event Interface sssssssssscsssscsssssssessscscsssssscesssscssessscesescacecessasscessesscessesscessesscecensssscees 3 Chapter 2 Software Installation inde 2 1 Preparing to Install the OPC Portal Server esssssssscesseceseesssssescscscesesceceseessceeessceeescacceaescsceessceeeesees 2 Set Administrator Privileges to Start a Service uussesesessesssnsssnennsnnnennnnnnennnnnnnnnnnnnnnnnnsnnnnsnnnnnnsnsnnnnnnsnnsnnnnn 2 Synchronizing the Real time Clock essssssssssesessscecesccecesescscesescscesesssceessescceesseceseeeceseescee
26. r 16 Right click to open the properties for the server select the General tab ICS TriplexOPCServer Properties General Location Security Endpoints Identity General properties of this DCOM application Application Name IESTrplez O PCS erver Application ID tdd558bde d9a 4800 beb3 ad33166b6ab c Application Type Local Service Authentication Level Service Name ICS Triples O PES erver gt Set the Authentication Level to None 17 Go to the Identity tab ICS TriplexOPCServer Properties General Location Security Endpoints Identity Which user account do you want to use to run this application Do the following a Select the radio button labelled The system account services only b Click OK to save the new settings and close the OPC Portal Server Properties c If you are not configuring a workgroup to use DCOM reboot the computer The configuration of DCOM is complete 18 If you are configuring a workgroup to use DCOM you must set the OPCEnum properties Do the following a Return to the DCOM Config section of the Component Services applet b Scroll down to locate OpcEnum 2 10 Document 553701 ICSTT RM407_EN_P Issue 03 c Right click to open the properties for OpcEnum select the Security tab OpcEnum Properties General Location Security Endpoints Identity
27. sed on information available at the time of its publication however the document contents are subject to change from time to time You should contact Rockwell Automation Technical Support by e mail icstsupport ra rockwell com to check if you have the latest version of this publication Copyright Notice Rockwell Automation 2012 This document contains proprietary information that is protected by copyright All rights are reserved Documentation Feedback Your comments will help us to serve your documentation needs better If you discover any errors or have any suggestions on how to improve this publication send your comments to our product support group icstsupport ra rockwell com This OPC Portsal Server User Guide applies to AADvance Release l 3 Document 553701 lil ICSTT RM407_EN_P Issue 03 OPC Portal Server User Guide AADvance Controller Issue Record Issue Date Comments Ol Dec 2008 First Issue 02 March 201 Baseline for Release 1 2 and Translation 03 June 2012 Release 3 version Document 553701 ICSTT RM407_EN_P Issue 03 Notes and Symbols used in this manual This symbol calls attention to items which must be considered and implemented when designing and building an AADvance controller for use in a Safety Instrumented Function SIF It appears extensively in the AADvance Safety Manual Note Notes are used extensively to provide important information about the product Standard Warni
28. the group Everyone to allow local and remote access c Click OK 12 Return to the COM Security tab of the My Computer Properties dialog box gt Goto the Launch and Activation Permissions area click Edit Limits Document 553701 2 8 ICSTT RM407_EN_P Issue 03 13 The Launch Permission window opens Launch Permission Security Limits Group or user names Administrators DALHART Administrators Pi Everyone Permissions for Administrators Local Launch Remote Launch Local Activation Remote Activation lt e lt E Do the following a Set all four permissions for both Administrators and Everyone b Click OK 14 Return to the COM Security tab of the My Computer Properties dialog box gt Click OK to save the changes made so far 15 Return to the Component Services applet Expand the My Computer item and select DCOM Config Locate the ICSTriplexOPCServer in the list Component Services E E ES Gction view Window Help a m X aa 2 8 ie Dcomconfig 171 objete _ Application ID A FLFDIEOL 3F Dc1821D5 11 40 4EE466 8F dd556bde 71 F58086EA DE mponent Services 2 Computers my Computer E COM Applicatic 3 DCOM Config Distributed Tran i 9 Running Process a Event viewer Local 3 ee Sty Services Local Document 553701 2 9 ICSTT RM407_EN_P Issue 03 OPC Portal Server User Guide AADvance Controlle