Contents
1. SERIES DUAL DRAFT GROSSING WORKSTATIONS 003 Formalin Dispensing System 2 5 Gallon capacity Nalgene poly dispensing container Dispensing valve provided for small controlled dispensing of customer supplied formalin MOPEC ME Series PAGE 25 SERIES DUAL DRAFT GROSSING WORKSTATIONS MOO004 Dictation Equipment Stand Angled surface for easy viewing of most dictation systems Dictation stand is portable and can be placed anywhere otainless steel construction Operation of Option The dictation stand can be placed on the shelf or any other flat surface Dictation Equipment Stand Video Link http mopec com media php id 73 MOPEC ME Series PAGE 26 ME SERIES DUAL DRAFT GROSSING WORKSTATIONS 005 Self Contained Exhaust Dual Two 2 dual blower fans w filters for air filtration complete with lighted on off switch and variable speed control on one 1 fan only Three 3 potassium permanganate filters provided with unit 009 Option only for ME400 ME600 amp ME650 Operation of Option The unit has two fans the first one runs when the main power switch is turned on The second blower motor must be turned on with the red switch next to the fan speed control The variable speed fan is operated by turning the controll to 100 and turning the knob to the desired speed This allows the fan to attain its full soeed and then adjust to the requested speed The filter saturation ra
2. SERIES ME100 200 ME300 400 600 650 DUAL DRAFT GROSSING WORKSTATIONS COUNTER TOP FREE STANDING ELEVATING REFERENCE USER The Better Product People MANUAL 21750 Coolidge Hwy Oak Park MI 48237 Rev 6 11 14 800 362 8491 Mopec com SERIES DUAL DRAFT GROSSING WORKSTATIONS IMPORTANT INFORMATION MODEL NO SERIAL NO DATE OF PURCHASE DATE OF INSTALLATION INSTALLATION NOTES SERVICE AND SUPPORT lt Mopec gt The Better Product People 21750 Coolidge Hwy Oak Park 48237 800 362 8491 Mopec com MOPEC ME Series PAGE 2 ME SERIES DUAL DRAFT GROSSING WORKSTATIONS TABLE OF CONTENTS FAMILY INTRODUCTION 4 FEATURES 5 AIR HANDLING 6 7 CUSTOMER AND TECHNICAL SUPPORT 8 INSTALLATION 9 CLEANING AND MAINTENANCE 10 WARRANTY 11 SAFETY LABELS 12 TROUBLE SHOOTING GUIDE 13 LIFT RESET PROCEDURE 14 CERTIFICATES 15 16 PRODUCT DRAWINGS ME100 17 ME200 18 ME300 19 ME400 Right Hand w disposal 20 ME400 Left hand w disposal 21 ELECTRICAL SCHEMATIC 115V 22 APPENDIX A OPTIONS 23 50 MOPEC ME Series PAGE 3 ME SERIES DUAL DRAFT GROSSING WORKSTATIONS FAMILY INTRODUCTION 5 ME Series Dual Draft Grossing Workstations come in a variety of styles which make them advantageous for a wide variety of users The countertop workstations ME100 amp 200 are ideal for small laboratories with limited space and requirements for
3. Aai s ad 06 17 2009 uH au NU Operation of Option The Formalin dispensing option is operated by turning on the electrical switch to activate the pump The pump is a self priming pump The amount of fluid is controlled by turning the needle valve to allow the liquid to flow Do not over tighten the dispensing valve when closing this could cause damage to the plastic needle valve seat or the needle To connect the formalin cube to the dispensing system Turn the pump off set the cube under the grossing station remove the cap install the male connector to the formalin cube push the female connector onto the male half until it clicks in place Turn on pump The pump may run for a few minutes to get to pressure Open valve to dispense fluid Formalin Dispensing Video Link http www mopec com media php id 104 MOPEC ME Series PAGE 47 SERIES DUAL DRAFT GROSSING WORKSTATIONS MO052 Perforated Grid Plate with Sink Stainless Steel constructed welded corners and stopper included Available on ME100 and ME200 MO053 Solid Grid Plate with Sink Stainless Steel constructed welded corners and stopper included Available on ME100 and ME200 MOPEC ME Series PAGE 43 SERIES DUAL DRAFT GROSSING WORKSTATIONS 059 Formalin Collection System MB600 and MB670 Includes collection funnel piped to a 2 1 2 gallon collection carboy w easy grip handles located under
4. ME100 or ME200 MO050 is not compatible with this option Operation of Option The ventilated trash container has a vinyl liner and is meant to have a trash bag inside the liner The trash can raises and lowers with the work surface The ventilation is connected to the grossing station with a 4 diameter vent hose Ventilated Trash Container Video Link http www mopec com media php id 76 MOPEC ME Series PAGE 40 SERIES DUAL DRAFT GROSSING WORKSTATIONS 0028 Computer CPU Bracket Adjustable width mounting bracket for CPU Two piece construction consisting of a mounted plate to the side panel of the Grossing Station and a sliding plate that adjusts to the width of the CPU CPU holder comes with tightening knobs or nuts to secure permanently rubber feet spacer block and safety strap Computer not included Operation of Option The CPU bracket is adjustable The CPU is secured in the bracket by the rubber feet and the outside bracket sliding to hold the CPU the safety strap is to keep the CPU from accidently being knocked off the grossing station The CPU should be centered in the bracket to support the unit properly MOPEC ME Series PAGE 41 SERIES DUAL DRAFT GROSSING WORKSTATIONS MO029 Removable Writing Ledge For additional writing surface on grossing stations Available only on the ME400 ME600 and ME650 MOPEC ME Series PAGE 42 SERIES DUAL DRAFT GROSSING W
5. for the ME series is 8 high at an angle of 60 Degrees and 44 Long with 994 3 16 x 5 8 holes The vent grill is perforated with 3 16 x 5 8 slots on 13 16 x 3 8 staggered centers yielding a 30 open area b Both specifications for Fan 1 and Fan 2 are free air cfm The preceding design parameters of the Mopec Grossing Stations and suggested ventilation requirements Are based on stringent ventilation requirements and ideal conditions Personalized conditions and practices may warrant an increase and or decrease of the ventilation MOPEC ME Series PAGE 6 ME SERIES DUAL DRAFT GROSSING WORKSTATIONS AIR HANDLING CONTINUED DESIGN PARAMETERS Non Recirculating The following chart is based on actual test data with the ME series Externally Exhausted Workstation Non Recirculating An optimum installation would provide 600 CFM of draft The chart will demonstrate static pressure at various quantities of air flow Mopec ME Series Workstation w o Filter amp w Grill MOPEC ME Series PAGE 7 ME SERIES DUAL DRAFT GROSSING WORKSTATIONS CUSTOMER AND TECHNICAL SUPPORT All Mopec staff members are Customer Service experts We believe in providing nothing but the best possible service for all our customers Our Technical Support group includes everyone from our design engineers to members of our production group All are dedicated to providing comprehensive and courteous support to all mopec cu
6. high demand ventilation The freestanding ME300 is designed for the larger capacity laboratories but utilizes a compact well ventilated footprint The elevating ME400 is designed for the larger capacity laboratories This unit features adjustable heights from 33 5 85 09 to 45 5 115 57 cm All ME units come standard with the unique dual draft ventilation system which allows airflow to be constant As the work surface accumulated grossing peripherals and tissues the air velocity will increase automatically MOPEC ME Series PAGE 4 ME SERIES DUAL DRAFT GROSSING WORKSTATIONS FEATURES All units in the series consists of the following Work Grid 14 Gauge type 304 Stainless Steel with a 4 Satin Finish Housing 18 Gauge Type 304 Stainless Steel with a 4 Satin Finish Electrical 115 v 1ph 60 Hz Current Draw 20 Amp maximum Optional 220 v 1ph 50HZ Current Draw 10 Amp maximum All units Perforated Grid Plates Hot Cold Water Fixture w Swing Spout G F C Electrical Receptacle Paper Towel Holder Adjustable Shelf Fluorescent Light Backdraft Grill Downdraft Chamber Replaceable Inch Centimeter Ruler Magnetic Tool Bar Optional features by unit consist of the following ____________ 014 5 Halogen Task Lighting Dual iner 2 X X X X X MOPEC ME Series PAGE 5 ME SERIES DUAL DRAFT G
7. is not working MOPEC ME Series Possible Solution Assure your facility circuit breaker has not been tripped Assure the has not been tripped off Reset to on Assure your facility circuit breaker has not been tripped Assure the G F C l has not been tripped off Reset to on ME400 unit ensure the doors are closed Assure Facility water valve is turned on Assure water valves on unit are turned on Assure water to unit Is on Assure hose 15 not kinked Assure your facility circuit breaker has not been tripped Assure the G F C l has not been tripped off Reset to on Reset circuit breaker on the bottom of disposal or switch box for the disposal PAGE 1 3 ME SERIES DUAL DRAFT GROSSING WORKSTATIONS LIFT RESET PROCEDURE The following instructions can be used to perform the reset procedure on motorized lift units These instructions should be used if a new controller is introduced to the system the limits have changed on the controller or if the system is simply behaving unexpectedly To reset the controller Turn the main power switch Off Approx 45 60 seconds Turn the main power switch On Press and hold the down button on the switch Continue holding the down button and the unit will continue downward Press and hold the down button approx 45 60 seconds on the switch at this point all legs should begin slowly creeping downward to the zero fully retracted p
8. ORKSTATIONS MO037 LCD Flat Screen Monitor 4 Keyboard Adj Arm System Allows positioning amp of LCD display for greater visibility Re position your LCD with just a touch Up down forward and back Full range of motion for maximum comfort level Keyboard Adjustable Arm Provides vertical and side to side motion Flat screen monitor keyboard and computer not included Operation of Option The adjustable arms allow positioning amp of LCD display for greater visibility and re position your LCD with just a touch Full range of motion for maximum comfort level up down forward and back Keyboard Adjustable Arm provides vertical and side to side motion Effortlessly position a keyboard in the most comfortable typing position seated or standing use Keyboard can be positioned for maximum comfort and productivity with a range of 25 6 65cm extend retract motion 11 1 2 29cm Height adjustment Tray tilts back at negative 5 Degree angle for ergonomic and healthy data entry Mouse tray slides out to left or right depending on user preference MOPEC ME Series PAGE 43 SERIES DUAL DRAFT GROSSING WORKSTATIONS MO038 Stainless Steel Shelf 1 One 14 L 8 Wide standard shelf For additional shelf surface on grossing stations Not Available on the ME600 and ME650 MOPEC ME Series PAGE 44 SERIES DUAL DRAFT GROSSING WORKSTATIONS 0039 Pneumatic Foot Operated Foot operated water control T
9. PEC ME Series PAGE 29 ME SERIES DUAL DRAFT GROSSING WORKSTATIONS 008 Rinse Bar Full rinse bar mounted inside the down draft area on the front side Control valve provided for water flow adjustment back flow preventer provided protection provided and built into fixture Operation of Option The rinse bar water flow is controlled by the valve The water must be connected to the grossing station The perimeter rinse is located under the plates and controlled by a star handles valve MOPEC ME Series PAGE 30 SERIES DUAL DRAFT GROSSING WORKSTATIONS 0009 Safety Splash Shield 11 x 12 Lexan shield on flexible arm for easy positioning Removable Operation of Option The Safety splash shield is on a flexible arm and can be moved up and out of the way as well as right and left The shield can also be removed from it s mount The splash shield may have some distortion due to the curve of the molded plastic shape The splash shield should be cleaned with soap and water and a soft cloth We recommend you do not use paper towels on the splash shield oafety Splash Shield Video Link http www mopec com media php id 7 1 MOPEC ME Series PAGE 3 1 SERIES DUAL DRAFT GROSSING WORKSTATIONS 0010 Hand Spray Rinse Chrome plated brass hand sprayer with soft spray 60 Long high pressure hose for easy and controlled rinsing of work surface Operation of Option Ensure the wat
10. ROSSING WORKSTATIONS AIR HANDLING REQUIREMENTS Series Dual Draft Grossing Workstations Design Parameters The ME Series Grossing Stations have been designed to adequately ventilate the work surface to insure the safety of the user The one adverse effect of adequate ventilation is noise The issue of noise has been given notable consideration but does not govern the ultimate design criteria Our design criteria are the most stringent utilizing standards as outlined by the Committee on Industrial Ventilation and Escape Velocity Parameters Design data is based on the table as a completely flooded vat of formaldehyde ldeal conditions in a grossing environment obviously do not warrant such a large amount of formaldehyde Therefore assumptions are made regarding grossing practices and ultimately formaldehyde concentrations Below is a chart of ventilation parameters for the ME series Grossing Workstations RE CIRCULATING VENTILATION SYSTEM a VOLUME Fan 1 Re Circulating Continuous Running 320 cfm b Fan 2 Re Circulating Variable Speed 0 320 cfm b a Re Circulating Self contained Exhaust Systems This system is simply a self contained exhaust system provide with the ME series Grossing Workstations Air is ventilated through the exhaust grill and circulated through potassium permanganate filters and exhausted out the top of the Grossing Workstation The exhaust fans are internal and are provided The grill
11. bal com gmi companies ME SERIES DUAL DRAFT GROSSING WORKSTATIONS wee u ww i gy CO PAGE 1 w X E MOPEC ME Series ME SERIES DUAL DRAFT GROSSING WORKSTATIONS PAGE 1 8 MOPEC ME Series ME SERIES DUAL DRAFT GROSSING WORKSTATIONS 1 9 MOPEC ME Series ME SERIES DUAL DRAFT GROSSING WORKSTATIONS h SL Ep 1 TALAMA d HERE 20 ME SERIES DUAL DRAFT GROSSING WORKSTATIONS FOR REFERENCE ONLY u ELI PAGE 2 MOPEC ME Series ME SERIES DUAL DRAFT GROSSING WORKSTATIONS CURSEI PITE TE Pe 0 9 00 5 33 HMM e elIsIb ulu a usIalIelnIo MOPEC ME Series PAGE 2 2 SERIES DUAL DRAFT GROSSING WORKSTATIONS Appendix A Option Information BL800 1HP HEAVY DUTY DISPOSAL Heavy Duty Includes Solenoid to supply water directly into disposal Vacuum Breaker to prevent back siphoning of water On Off switch requires separate power circuit other than grossing station x 7 Operation of Option The BL800 dispo
12. er is connected to the unit and the spray rinse valve is opened The water pressure is regulated by the deck mounted valve Press the lever on the spray head to utilize the spray rinse Hand Spray Rinse Video Link http www mopec com media php id 6 7 MOPEC ME Series PAGE 32 SERIES DUAL DRAFT GROSSING WORKSTATIONS M0011 Halogen Light Magnifier Dimension 4 H x 5 5 6 W Poly magnifier with 2X magnification One 1 each provided Operation of Option The magnifying glass is mounted to the halogen light option MO015 020 The magnifying glass has a swivel base and can be moved to accommodate right of left hand operators MOPEC ME Series PAGE 3 3 SERIES DUAL DRAFT GROSSING WORKSTATIONS MO014 Video Camera Arm Easy positioning of camera over full length of grossing station Overhead positioning with articulating arm to support most camera systems Video camera not included Operation of Option The video arm can be moved the length of the grossing station and be configured to overlook an operation at the table To move the arm the top turn knob must be loosened and the arm will slide to the new position and the knob tightened to hold the arm in place Video Camera Arm Video Link http www mopec com media php id 70 MOPEC ME Series PAGE 3 4 SERIES DUAL DRAFT GROSSING WORKSTATIONS 015 Halogen Task Lighting Dual Two 2 halogen lights on a 20
13. ight dispensing Operation of Option The Literature Dispenser can stand on its base or it can be wall mounted near your work station Literature Dispenser Video Link http www mopec com media php id 68 MOPEC ME Series PAGE 3 8 SERIES DUAL DRAFT GROSSING WORKSTATIONS 020 Halogen Task Lighting Single One 1 halogen light on a 20 inch flexible arm for convenient positioning 20 watt Halogen Bulb Operation of Option The task lights have a switch on the top front of the grossing station The task light can be moved to shine on most areas of the work surface of the grossing station DO NOT TURN THE LIGHT Simply bend the arms to move out of the way To move the arm hold the metal loop and place in position The light does get hot to the touch To change the bulb the set screw must be loosened on the light case The case can be unscrewed at the light end Insert the new bulb and screw the case on and tighten the set screw CAUTION Do not touch the new bulb with your bare fingers the oils in your skin will shorten the life of the bulb Halogen Task Lighting Video Link http www mopec com media php id 78 MOPEC ME Series PAGE 30 SERIES DUAL DRAFT GROSSING WORKSTATIONS MO023 Ventilated Trash Container Dimensions 8 Wide x 15 3 8 Deep x 28 H Removable stainless steel trash container 12 gallon capacity Connects to grossing station ventilation system Not available on the
14. inch flexible arm for convenient positioning 20 watt Halogen Bulbs Operation of Option The task lights have a switch on the top front of the grossing station The task light can be moved to shine on most areas of the work surface of the grossing station DO NOT TURN THE LIGHT Simply bend the arms to move out of the way To move the arm hold the metal loop and place in position The light does get hot to the touch To change the bulb the set screw must be loosened on the light case The case can be unscrewed at the light end Insert the new bulb and screw the case on and tighten the set screw CAUTION Do not touch the new bulb with your bare fingers the oils in your skin will shorten the life of the bulb Halogen Task Lighting Video Link http www mopec com media php id 78 MOPEC ME Series PAGE 3 5 SERIES DUAL DRAFT GROSSING WORKSTATIONS 016 Camera Stand Vertical camera stand with X Axis amp Y Axis adjustable arm Capable of supporting both digital and 35MM type cameras Ruler for recording height adjustment Cameras not included ra P 9 gt 7 P a a Operation of Option The adjustable axis allows positioning the camera for greater versatility and ease of operation The camera stand can be lowered or raised with the turn of a knob Camera can be adjusted to the front or back with the turn of a knob The camera mounting k
15. lp alleviate dirt from the grain finish Scratches can be removed simply by utilizing a non metallic abrasive pad and rubbing in the same direction as the satin finish Since most abrasive pads vary from one supply to another we suggest rubbing the entire surface to blend the scratch and blend the balance of the surface Plexi glass surfaces will scratch if cleaned with an unsuitable cleaner and improper cleaning Many plastic cleaners are available and we suggest using one Wipe dry with a clean absorbent cloth or paper towel turning often MOPEC ME Series PAGE 1 0 ME SERIES DUAL DRAFT GROSSING WORKSTATIONS WARRANTY MOPEC ME SERIES GROSSING STATION LIMITED WARRANTY Products manufactured by Mopec will be free from defects in material and workmanship and conform to Mopec s description or specifications If a warranty claim is made within one 1 year from the earlier if the date of acceptance first beneficial use the defective or nonconforming Product or Part thereof will be repaired or at Mopec s option replaced free of charge FCA Mopec s dock All warranty claims must be writing and received by Mopec within the warranty period The warranty is not transferable other than to customers of Mopec s authorized Distributors and will not apply unless the Equipment has been properly installed maintained and operated in accordance with all instructions and does not apply to defects nonconformities or other failu
16. nob is provided to mount your digital or 35mm camera The set screws are provided to lock the camera in place when mounted The camera is mounted to the mounting knob and the locking ring helps keep the camera locked onto the knob MOPEC ME Series PAGE 36 SERIES DUAL DRAFT GROSSING WORKSTATIONS 018 Formalin Collection System ME100 ME200 and ME600 and ME650 Includes collection funnel piped to a 2 1 2 gallon collection carboy w easy grip handles located under the grossing station Quick disconnects included with safety caps provided for safe transport to disposal or recycling area Available on ME100 with leg frame option only Formalin not included Operation of Option The formalin collection system is piped from the collection point at the sink to the storage bottle below the grossing station with vinyl tubing The collection system has a stainless steel funnel to allow simple pouring of the formalin to be collected The Formalin collection bottle has quick disconnect caps for the hose and the bottle to allow for safe handling of the carboy container A stainless steel pull out containment tray is provided for easy access and spill containment MOPEC ME Series PAGE 3 SERIES DUAL DRAFT GROSSING WORKSTATIONS ME019 Literature Dispenser Lexan literature dispenser capable of holding 1 thick pads of forms or letter size documents for easy handling and distribution Three 3 tiers for upr
17. oggle on off foot operated Hand operated mixing lever located next to faucet Operation of Option The Pneumatic foot operated control for water is an on and off valve Press one for the water to come on press again when ready for the water to shut off The foot pedal does not control the water pressure The mixing valve controls the water temperature and does not control the water flow rate Flow rate can be adjusted with adjustable water pressure regulators not supplied or by closing the water shut off valves between the wall and the unit MOPEC ME Series PAGE 45 SERIES DUAL DRAFT GROSSING WORKSTATIONS MOO050 Ventilated Trash Receptacle on casters Removable stainless steel trash container with 12 gallon capacity Dimensions 15 W x 15 H x 38 5 off floor 3 swivel casters with brake mechanisms Connects to grossing station ventilation system Not available on the ME100 or ME600 or ME650 023 16 not compatible with this option Operation of Option The ventilation is connected to the grossing station with a 4 diameter vent hose MOPEC ME Series PAGE 46 SERIES DUAL DRAFT GROSSING WORKSTATIONS M0051 Formalin Dispensing System Cubetainer Includes pump and deck mounted valve Quick Connect coupler to connect the formalin cube Option for ME100 and ME200 with purchase of leg frame Available on ALL ME Models Does not include the formalin collection system or formalin ug
18. osition Continue holding the down button until the system has reached its zero Bottom position Your lift system should be reset to its home position at this time To verify try operating the system by moving it upwards with the up button and again downwards ensure the system returns to the home position If this should not correct the problem please contact at 800 362 8491 MOPEC ME Series PAGE 1 4 SERIES DUAL DRAFT GROSSING WORKSTATIONS Certificate TUV License Holder Manufacturing Plant Mopec Inc Mopec Inc 21750 Coolidge Hwy 21750 Coolidge Hwy Oak Park 48237 Oak Park MI 48237 USA USA Test report no USA GB 30471065 001 Client Reference Rick Bell Tested to UL 61010 1 2004 CAN CSA C22 2 61010 1 2004 NFPA 79 2002 Certified Product Grossing Station License Fee Units Model Designation MMBXXXX 7 X 0 9 A Z not safety relevant Rated Voltage 115V 60Hz ated Current 20A Protection Class I Special Remarks To be installed according to the licensee s installation instructions 1 1 Licensed Test mark Signatures Date of Issue day mo yr Quo 04 02 2005 Stephan Schmitt Dipl Ing M President QA Certification Officer Rheiniand of North America Inc 12 Comunarce Road Newtown 06470 Tel 203 426 0688 Fax 2031 426 4009 MOPEC ME Series PAGE 1 5 CERTIFICATE OF REGISTRATION Thi
19. re due to Equipment misuse abuse modifications or other causes outside Mopec s control If a warranty claim is made in writing within the warranty period the defective or nonconforming Equipment or Part thereof will be repaired or at Mopec s option replaced free of charge FCA Mopec s dock THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF THE WARRANTY AS SET FORTH HEREIN IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE To the extent that Mopec is acting as a supplier of Products manufactured by a third party the Products will be warranted only to the extent that they are warranted by their manufacturers and Buyer or its customer agrees to look solely to the Product manufacturer for all warranty claims MOPEC 21750 COOLIDGE HIGHWAY OAK PARK MI 48237 MOPEC ME Series PAGE 1 1 SERIES DUAL DRAFT GROSSING WORKSTATIONS BEFORE SERVICING THE UNIT LOOK FOR AND HEED THE FOLLOWING LABEL WARNING HAZARDOUS VOLTAGE DISCONNECT POWER BEFORE SERVICING OR OPENING COVER Symbols Found on the Equipment MAIN POWER FAN SPEED MOPEC ME Series PAGE 1 2 ME SERIES DUAL DRAFT GROSSING WORKSTATIONS TROUBLE SHOOTING GUIDE Problem My Unit does not turn on My unit does not elevate My unit s faucets do not work My hand spray does not work My disposal
20. s is to certify that MP Acquisition LLC DBA Mopec 21750 Coolidge Highway Oak Park Michigan 48237 USA operates a Quality Management System which complies with the requirements of ISO 9001 2008 for the following scope of registration The registration covers the quality management system for the design engineering manufacturing and installation of equipment and distribution of supplies for morgue pathology histology and necropsy applications Certificate CERT 0078089 Original Certification Date April 9 2008 File 1068177 Current Certification Date April 7 2014 Issue Date March 11 2014 Certificate Expiry Date April 6 2017 Chris Jouppi President Samer Chaouk QMI SAI Canada Limited Head of Policy Risk and Certification ACCREDITED ISO 9001 Registered by SAI Global Certification Services Pty Ltd 286 Sussex Street Sydney NSW 2000 Australia with QMI SAI Canada Limited 20 Carlson Court Suite 200 Toronto Ontario MEN 7K6 Canada SAI GLOBAL This registration is subject to the SAI Global Terms and Conditions for Certification While all due care and skill was exercised in carrying out this assessment 2 Global accepts responsibility only for proven negligence This certificate remains the property of SAI Global and must be returned to them upon request INFORM INSPIRE IMPROV To verify that this certificate is current please refer to the SAI Global On Line Certification Register www qgmi saiglo
21. sal is an option for disposing of tissue and bone pieces that are not needed The disposal switch activates the disposal and allows water to enter the disposal from the electric solenoid When the disposal is turned off the water stops The vacuum breaker prevents back siphoning of water through the disposal The disposal option requires one 20 amp circuit dedicated to the disposal MOPEC ME Series PAGE 23 SERIES DUAL DRAFT GROSSING WORKSTATIONS 001 Self Contained Exhaust Single One 1 dual blower air filtration system complete with pilot lighted on off switch variable speed control amp filter caddy Two 2 potassium permanganate filters provided with unit 09 Option only for 100 amp 200 See catalog pages 175 for further details Operation of Option The blower motor must be turned on with the red switch next to the fan speed control The variable speed fan is operated by turning the control to 100 and turning the knob to the desired speed This allows the fan to attain its full soeed and then adjust to the requested speed The filter saturation rate depends on hours of operation and fumes to be filtered Instructions on how to change and check the saturation of the filters are shown in the following links Replacing Filters Video Link http www mopec com media php id 79 Filter Evaluation Video Link http www mopec com media php id 80 MOPEC ME Series PAGE 2 4
22. stomers The following information is included to help our customer communicate with Customer and Technical Support at Mopec Mopec 21770 Coolidge Hwy Oak Park Michigan 48237 800 362 8491 248 291 2040 248 291 2050 FAX MOPEC ME Series PAGE 8 ME SERIES DUAL DRAFT GROSSING WORKSTATIONS INSTALLATION The installation procedure is quite important to assure 100 functionality with the equipment Upon unpacking the unit carefully place it in the area where it is to be used Placing a bubble level on the unit s edge side to side and front to back assures the unit is completely level Note It may be necessary to use stainless steel shims to acquire a true level unit Open the access panels and check the plumbing and electrical locations to confirm their rough in position Carefully mark the four mounting pads for fastener drilling and the outer and inner perimeter of the pedestal Once the floor is clearly marked move the table away and drill the floor for the fasteners Place a liberal amount of high grade silicone between the outer and inner perimeter outline of the pedestal Place the table on the silicone and adjust to the alignment marks Mount the unit as required with an approved fastener The fastener is suggested as being a minimum dimension of 3 8 diameter and having a Tensile Pullout Load of at least 4 000 Ibs Once the unit is mounted you can add a final bead of silicone to complete the seal of the j
23. te depends on hours of operation and fumes to be filtered Instructions on how to change and check the saturation of the filters are shown in the following links Replacing Filters Video Link http mopec com media php id 79 Filter Evaluation Video Link http mopec com media php id 80 MOPEC ME Series PAGE 27 SERIES DUAL DRAFT GROSSING WORKSTATIONS 006 Leg Frame Height 34 Heavy duty all welded leg frame with adjustable feet for leveling Stainless steel construction Option only for 100 amp 200 MOPEC ME Series PAGE 28 SERIES DUAL DRAFT GROSSING WORKSTATIONS 007 Foot Pedal Dual foot pedal Hot Cold water control valve with swing spout faucet Wrist blade handle controls are not available with this option Option available on ME200 with the purchase of a leg frame Shipped loose with ME200 Also available on ME300 ME400 ME600 and ME650 Operation of Option The foot pedal is operated by pressing down on the right pedal for cold and the left pedal for hot Pressing both pedals will mix the hot and cold water Water pressure adjustment is limited by the short stroke of the pedal if your water pressure is high try adjusting the pressure by closing the shut off valve installed between the wall and the unit or adjustable water pressure regulators can be installed not supplied with unit Foot Pedal Video Link http www mopec com media php id 72 MO
24. the grossing station Quick disconnects included with safety caps provided for safe transport to disposal or recycling area Not available on MB100 Formalin not included Operation of Option The formalin collection system is piped from the collection point at the sink to the storage bottle below the grossing station with vinyl tubing The collection system has a stainless steel funnel to allow simple pouring of the formalin to be collected The collection has a float sensor and indicator light to notify the operator the collection bottle is full The Formalin collection bottle has quick disconnect caps for the hose and the bottle to allow for safe handling of the carboy container Has a pull out containment tray to access the collection carboy Formalin Collection Video Link http www mopec com media php id 75 MOPEC ME Series PAGE 49 SERIES DUAL DRAFT GROSSING WORKSTATIONS CP001 Communication Data Port Two port Ethernet receptacles Allows for connection to in house network Leads can be left for facility to tie into the building have a connection on the back of the unit or on the side of the unit where a computer may mount CP002 Communication Wire Chase 1 5 8 diameter Conduit organizes network cables and helps eliminate clutter Can be located on back splash of unit MOPEC ME Series PAGE 50
25. unction between the floor and pedestal Fill any gaps with silicone and smooth for finish trim Once the unit is secured to the floor the utilities can be hooked up The cold water line is 34 and the hot water 1 gt hard copper which will require customer supplied on off valves Mopec suggests using ball type water valves to assure proper water flow for operating all table accessories Drain lines are standard 1 1 2 IPS and need to be vented to assure proper drainage Electrical requirements are solely dependent on accessories If the table excludes a disposal one 1 115v 1ph 60Hz 15 amp circuit is sufficient If a disposal is included a second 115v 1ph 60Hz 15 amp circuit must be added This second circuit will be tied into the same junction box but wired independently MOPEC ME Series PAGE 09 SERIES DUAL DRAFT GROSSING WORKSTATIONS CLEANING AND MAINTENANCE All stainless steel surfaces can be cleaned with soap and water which will remove debris The stainless steel surfaces can be disinfected with a non caustic disinfectant We suggest using BE045 PathCloud or 47 Bench Wipe for cleaning purposes We recommend you NOT USE a bleach solution to clean your unit bleach will eventually erode stainless steel if not thoroughly rinsed The use of chlorine bleach will VOID THE STAINLESS STEEL WARRANTY During the cleaning we suggest wiping the surface in the same direction as the satin finish which will he