Home
Pro 800/1000 User Manual - Coroma Garage & Industrial Doors
Contents
1. Depending on the peripherals installed and the operating options set by your installer the Dexxo Pro system may perform the following special operations Operation in Total opening mode with a Telis type remote control or similar Fig 9a Safety photoelectric cell operation An obstacle detected between the cells will prevent the door from closing The door will stop and then completely or partially reopen depending on the setup selected during installation when an obstacle is detected during the close cycle The light will flash for 30 seconds during this process Pedestrian door safety function Opening a pedestrian door within the garage door will prevent the door from moving The light will flash for 30 seconds during this process Flashing orange light The orange warning light will flash every time the door moves A two second delay before the door starts to move can be selected during installation Remote lighting operation The light comes on every time the motor drive unit is operated The light will go out one minute after the door stops moving The time delay can be adjusted during installation If a remote control button is programmed for remote lighting it works as illustrated in Fig 10 Automatic closure mode operation The door is automatically closed after a time delay set at the time of installation An additional command during this time will cancel th
2. made from outside Press a button on the memorised remote control to stop the siren Start a complete opening and closing cycle H2 Detection of forced entry Indicates that an attempt to open the garage door has been made from outside Press a button on the memorised remote control to stop the siren Start a complete opening and closing cycle lf other codes are displayed contact your Somfy installer Power outage Following a power outage the motor must recognise its fully open position again Open the door fully using a memorised remote control The door will open at a degraded speed Allow the door to open to the fully open position PERIPHERALS Anumber of peripherals are available Key Description Comments 1 Keytis 2NS RTS remote control Hand held 2 channel remote control 2 Keytis 4NS RTS remote control Hand held 4 channel remote control 3 Keygo remote control Four channel keyring remote control 4 RTS pushbutton Wall mounted 2 channel remote control switch 5 RTS radio code keypad Access code control point For use outside the garage 6 Photoelectric cells To prevent door closure if an obstacle is detected 7 Orange light To signal a warning when the door operates 8 Ke
3. manual release cord for a manually operated door may fall quickly due to weak or broken springs or if it is badly balanced Before manually operating the door or performing maintenance work always turn the power off and where necessary remove the battery Fig 1 Never let children play with door control systems Keep the remote controls out of reach of children Fig 2 When replacing the light bulb select a 230 V 40 W E14 type Fig 3 Regularily check the operation of the door to identify any sign of wear deterioration or incorrect balancing Do not operate the door if repairs or adjustments are required Remain at a safe distance when operating the door PRODUCT PRESENTATION Description Fig 4 The Dexxo Pro system is designed to power garage doors in residential use This motor drive system comprises e A motor head 1 with integrated light 2 and digital operating display 5 Arail assembly 3 with a manual release cord 4 OPERATION AND USE Normal operation Operation in Total opening mode with a Keygo type remote control or similar Fig 5a Operation in Partial opening mode with a Keygo type remote control or similar Fig 5b N se lt ye sa va Wo AA ANAS O OR eO N DP CP oe Obstacle detection operation Fig 6 and 7 When an obstacle is detected during the open cycle the door will stop Fig 6 When an obstacl
4. operated for a number of cycles using battery power three times a year Battery replacement Keytis Keygo RECYCLING Do not dispose of your scrapped appliances nor your used batteries with household waste You are liable to dispose of all your electronic or electrical equipment waste by relocating over to a dedicated collection point for recycling TECHNICAL SPECIFICATIONS Basic technical specifications Dexxo Pro 800 Dexxo Pro 1000 Mains power supply 230 V 50 Hz Power consumption on standby 5 W Max power consumption 600 W with 500 W remote controlled lighting Traction force Peak force 800 N 1000 N lice 20 cycles per day with a standard rail tested for 36 500 cycles 50 cycles per day with a high performance rail tested for 90 000 cycles Number of channels that can be memorised 32 Somfy radio frequency 433 42 MHz RTS Integrated light 230 V 40 W max E14 socket Remote controlled lighting 230 V 500 W max Class 2 L Operating temperature 20 C 60 C
5. CONTENTS GENERAL PRESENTATION The world of Somfy Support SAFETY INSTRUCTIONS Standards Safety instructions oo PRESENTATION OPERATION AND USE Normal operation Special operation Adding a remote control without accessing the motor head TROUBLESHOOTING Digital display Power outage PERIPHERALS MAINTENANCE Replacing the bulb in the light unit Checking Battery replacement cial SPECIFICATIONS Nn ana Ol np wo W IND rh po N GENERAL PRESENTATION Thank you for choosing a Somfy product This product is designed and manufactured by Somfy in line with quality procedures that are ISO 9001 compliant The world of Somfy Somfy develops produces and sells automation systems for residential and commercial applications Alarm systems automatic blinds and shutters garage doors and gates all Somfy products are designed to fulfill your needs in terms of safety comfort and security At Somfy the quest for quality is a continual process Somfy has built its reputation on the quality of its products and is synonymous with innovation and technological leadership worldwide Support Getting to know you listening answering your needs is all part of the Somfy approach Please contact your local Somfy retailer or installer for details on other Somfy products Internet www somfy com SOMFY SOMFY SAS capital 20 000 000 Euros RCS Annecy 303 970 230 SAFETY INSTRUCTIONS Standards This produ
6. ct complies with the safety specific rules for powering vertically opening garage doors in residential use requirements standard EN 60335 2 95 When installed in line with these instructions and in compliance with the Installation Checklist the product will be compliant with standards EN 13241 1 and EN 12453 The instructions referred to in the Installation Manual and Instructions for Use of this product are designed to ensure that damage to property and injury to persons is avoided along with compliance with the above standards Failure to comply with these instructions absolves Somfy from any liability for any damage that may be caused Dexxo Pro is a product that must be installed inside the garage with a built in back up control system Somfy hereby declares that the device is compliant with the essential demands and other relevant requirements of directive 1999 5 CE A declaration of compliance is available from the web site at www somfy com ce Dexxo Pro This product is usable in the European Union and in Switzerland These are important safety instructions For safety reasons it is important to always follow all instructions Retain these instructions for future reference Safety instructions Every month test that the motor drive unit reverses its motion when it encounters an obstacle that is at least 50 mm from ground level If this is not the case call your installation specialist Always be very careful when using the
7. e automatic closure and the door will remain open The next command will close the door Working from the back up battery If a back up battery is installed the Dexxo Pro motor will operate when a power cut occurs The following conditions apply to operation e Door speed is reduced e The light will not come on e The safety devices are disabled Battery specifications Endurance The battery will last for 24 hours with a maximum of 5 to 10 operating cycles depending on the weight of the door e Recharging time 48 hours e Service life prior to replacement approx three years To ensure optimum battery life we recommend that the power to the motor is switched off and the door is operated for a number of cycles using battery power three times a year Forced operation mode Fig 11 This function is used to move the door at any time remote control lost safety mechanism failure etc Remove the built in lighting cover e Control door motion using the and buttons e Pressing and holding the button will trigger closure e Pressing and holding the button will trigger opening Detection of forced entry operation Detection of forced entry starts operating 30 seconds after the door is closed lf forced entry is detected the siren will sound for 2 minutes the light integrated in the motor and the orange light if installed will flash To stop the siren press a button on a memorised rem
8. e is detected during the close cycle the door will stop and then reopen Fig 7 Once an obstacle has been detected the light will flash for 30 seconds Light operation The light will come on each time the motor drive unit is operated The light will go out one minute after the door stops moving Repetitive use that causes the light to be continually on may result in a thermal cut out this will automatically turn the light off Manual release cord operation Fig 8 Dexxo Pro is fitted with a manual release mechanism so that you can move the door manually should a power failure occur for example The manual release mechanism should be easily accessible and located no more than 1 80 metres above floor level 1 Disengaging the motor drive mechanism Pull on the manual release cord until the door drive mechanism is disengaged 2 Manually moving the door This is possible as long as the door drive mechanism is disengaged 3 Reengaging the motor drive mechanism Move the door manually until the drive mechanism comes to reengage itself into the transmission rail may be dangerous Only use the cord to disengage the motor drive mechanism Never use the cord to move the door manually Always reengage the motor drive mechanism before sending another command to the motor drive unit A When disengaging the motor drive mechanism use caution for a badly balanced door may cause sudden door movement that Special operation
9. ote control Adding a remote control without accessing the motor head With a Keygo Fig 12a TROUBLESHOOTING Digital display The LCD display is situated under the lighting cover It provides motor operation status The main operating codes are as follows With a Telis or similar Fig 12b Code Description Comments C1 Waiting for a command C2 Door opening C3 Waiting for the door to close C4 Door closing C5 Obstacle detection Indicates that the door encountered an obstacle The display is maintained for 30 s after detection C6 Safety input active Indicates that an obstacle preventing door closure is present between the photoelectric cells or is in contact with the safety sensor bar installed on the door c9 Pedestrian door safety contact active Indicates that the pedestrian door within the garage door is open Door operation is inhibited Cb Permanent hardwired control Indicates that the hardwired control input is permanently active Commands from radio remote control units are inhibited CC Maintenance is required Indicates that maintenance is required on the installation Contact your installer Cd Working from back up battery Indicates that the main power supply to the motor is cut and that the motoris powered by the battery back Waiting for a command up pack H1 Detection of forced entry Indicates that an attempt to open the garage door has been
10. yswitch Keyswitch for secure control 9 Battery To provide continued operation during a power cut To engage the manual release system from the outside using the existing door handle 10 Release lock l S Highly recommended when the garage door is the only access point into the garage l To engage the manual release system from the outside using the existing door handle 11 Outside release lock l l e Highly recommended when the garage door is the only access point into the garage 12 Door locking kit A system to reinforce door locking MAINTENANCE Replacing the bulb in the light unit Fig 14 1 2 Remove the light cover 3 4 Unscrew and replace the defective light bulb 5 6 7 Refit the light cover Use a 230 V 40 W E14 socket light bulb Checking The obstacle detection function Every six months check that the door reverses direction when an obstacle prevents the door from closing at least 50 mm above floor level The safety mechanisms cells pedestrian door contact sensor bar Check correct operation every six months refer to page 4 The back up battery To ensure optimum battery life we recommend that the power to the motor is switched off and the door is
Download Pdf Manuals
Related Search
Related Contents
Wellness Collection BIOLEES® MP - partner sa STIHL BT 120 C Manual de instruções IBM Flex System Storage Expansion Node 全ページ一括(PDF/4.04MB) Genius GPP-1000 Conceptronic Optical Audio (Toslink) Cable KX-DT521 KX-DT543 KX-DT546 KX-DT590 - Psn USER MANUAL Copyright © All rights reserved.
Failed to retrieve file