OLC 7030 (DALI) - Philips Lighting
Contents
1. below An OLC with default configuration will fall back on photocell input when no communication is detected default value is after hour In case this is not detected it will follow the On Off scheduler only if the real time clock information is available in the OLC and a back up schedule is set In case this is also not available will go on to Power Up state configurable by the user Safe guard mechanism with photocell The OLC can be configured to fall back onto photocell operation mode when it detects a communication failure with the SC This safe guard mechanism prevents light points from staying OFF during the night causing dangerous situations and from staying ON during the day which would waste energy The OLC is equipped with one single pole 230VAC input to monitor the photocell operation When in safe guard mode the OLC output will follow the photocell input Note It is only possible to connect photocells which use an electromagnetic relay Safe guard mechanism with back up scheduler The back up scheduler is the default back up mechanism of the OLC is not configured otherwise When the OLC detects a communication failure with the SC it will continue to operate according to a predefined back up schedule The OLC will run on its own internal real time clock and use this schedule to switch tts output In this operation mode the OLC will not regulate the light levels Note Check if feature is supported by th
2. II Touch and DALI for PL L PL T PL C lamps e PHILIPS outdoor Xitanium Prog DALI LED 40W 75W 100W and 50W Any other component must be validated before it may be used with the OLC Contact your local Philips representative about how to obtain component validation A Warning The DALI interface does not use safety isolation DA is internally connected to the Neutral conductor Disconnect the main power supply before servicing Wiring Diagram 0 25 2 5 mm m Filter 4 DALI is not using c g safety isolation Li Ni No Lo Ls Le DA DAHDA DAH _ 10 11 mm y f 4 4 Max 6A DALI driver 1a gt 5 5 Ah L N Li Line input Ni Neutral input Ls Switched Line output No Neutral output Lc Controlled Line input Photo cell 0 25 2 5 mm Filter 4 EAn is D using D y isolation a Li Ni No Lo Ls Le DA DAHDA DAH m 10 11 mm y 4 4 4 Max Lo Advert 6A po light 3 DALI driver ta L N Li Line input Lo Line output not switched Ni Neutral input Ls Switched Line output No Neutral output Lc Controlled Line input Photo cell LLC7030 Datasheet Outdoor Luminaire Controller DALI User interface The OLC has two push
3. LLC7030 Datasheet Outdoor Luminaire Controller DALI ooooooooou miin Dimensions in mm CE Note Check if feature is supported by the Central Management Software CMS 1 5 General Description The Outdoor Luminaire Controller OLC is a high performance LonWorks network device that connects to a lamp driver combination to control and monitor Communication with the OLC is established via the power line utilizing the LonTalk open protocol The OLC interacts with the lamp driver by means of a DALI interface and when needed switching also its mains voltage line The OLC can autonomously switch its output ON and OFF if combined with a photocell The OLC is designed to work in combination with the Philips Starsense Segment Controller SC Applications Each LLC7030 is able to monitor and control up to two independent lamp drivers It is possible to use two DALI drivers per output to monitor and control two light points As a result certain feedback is combined power or reported for one driver only lamp voltage driver temp It is designed for use in highway residential street and road lighting applications including parking lots ports train stations and industrial complexes The design of the OLC is optimized for mounting within a luminaire or in the base of the pole For optimal system performance please respect the specified maximu
4. buttons one for testing the lamp driver and one to send its unique Neuron ID number to the Segment Controller see Starsense User Manual for more information The test button can also be used as maintenance indicator PHILIPS Status LEDs Power LED Neuron LED ate Status LEDs LED and 2 will show which output is switched ON Power LED Will show device or output status If it s continuously in blinking mode the OLC is in error mode consult your local Philips representative Neuron LED Will show when Neuron ID is sent The yellow service LED indicates the internal OLC state ON Application less The OLC has only communication parameters loaded Unconfigured This OLC state indicates that it has communication parameters and an application program and network address information This OLC state is the idle state Commissioning and configuration need to be performed Configured Blinking OFF From the factory the OLC is configured for a default lamp and is operating normally 3 5 Test button e Pressing the test button while the output is OFF will switch the output ON for a maximum of 15 minutes The output will be turned OFF after the timer has expired During this period the red LED blinks slowly e Pressing the test button while the output is at maximum level will cause the output to switch to dimmed level for 15 minutes The output will be turned OFF after the timer has expired During thi
5. ction Mains voltage Mains frequency ax load wattage 220 240V 10 50 60 Hz 5 1000W 2 x 400W DALI drivers including advert light Power consumption Stand by wattage lt 2W Connector block ains connector WAGO 804 series contact cage clamp connection 0 25 2 5 mm solid 0 25 2 5 mm fine stranded 0 25 1 5 mm fine stranded with ferrule and plastic collar 0 25 2 5 mm fine stranded with ferrule without plastic collar 20 12 AWG solid 10 11 mm Wire cross section mm Wire cross section AWG Wire strip length LLC7030 Datasheet Outdoor Luminaire Controller DALI Power line interface Channel type Coupling Protocol Power line transceivers Frequency band Approval Filter DALI interface Interface Number of DALI interfaces Master slave Insulating System Applicable DALI Standards Power supply Protection Communication protocol Marking Output voltage External DALI powersupply PL 20C power line Line to Neutral Non lsolated Coupling ANSI EIA 709 Compliant to ANSI EIA 709 2 CENELEC consumer band C band 132 5kHz automated B band 1 OkHz selection if communication on C band fails FCC and CENELEC EN50065 compliant RoHS directive 2002 95 EC REACH SVHC nternal band stop filter to filter interference from the lamp driver Compliant to IEC 60929 2004 Annex E 2 individual DALI ports max 2 drivers per port The OLC operates as a Master lighting c
6. e Central Management Software CMS 4 5 The switch ON level can be pre configured through the OLC power up value Attention In case the OLC is powered off and the communication is still not establish at power up time the real time clock will not be available so back up scheduler will not be active Lamps will simply turn ON and stay like this To prevent this behaviour a safe guard mechanism based on a photocell can be configured Daylight control based on photocell operation n Daylight Control Mode DCM the switching points are controlled by the available sunlight via a photocell and the light level is controlled by the Starsense system When OLC is configured in DCM will follow he photocell input with its output while still receiving and executing he dimming levels from the segment controller Monitoring function of the OLC are not influenced by the DMC The following functional able represents the correlation between available light levels photocell operation and the OLC output Dusk Closed Mains voltage on OLC input Lc Dawn Open l OVolt on OLC input Le Technical data Operating conditions Temperature Relative humidity Max housing temperature 25 C to 70 C 10 to 90 75 C on Tc spot see OLC cover If the Tc rises beyond 85 C during use the OLC will switch off the relay load Non operating conditions Temperature Relative humidity 40 C to 85 C 5 to 90 Mains conne
7. ition H 15 6 cm W 6 3 cm D 6 3 cm 0 31 kg EN6 1347 2 1 EN6 1547 EN50065 2 CISPRI5 edition 7 1 LONWORKS and Neuron are trademarks of the Echelon Corporation registered in the Weight Kg net gross 4 99 5 08 Ordering Data Type LLC7030 OLC DALI Ordering number 9137 003 38703 EAN code level 87115 59732817 EAN code level 3 87115 5973283 EOC 732817 99 322 636 36125 10 2013 PHILIPS Data subject to change www philips com lightingcontrols
8. m lightpoints connected to a Segment Controller see datasheet The OLC is released and authorized to interact solely with the Philips Starsense SC Consult the local Philips representative if desired otherwise X Tip When you switch the lamp driver ON OFF by means of a DALI command the Switched Line Output Ls can be used for another type of load e g advert light Christmas lights etc The OLC gathers energy lamp voltage and power information from the driver if available For best system performance it is recommended to use Philips DALI drivers PHILIPS LLC7030 Datasheet Outdoor Luminaire Controller DALI General operation The OLC combines three main functions The controller function receives the incoming commands from the SC and acts accordingly The OLC can control the lamp driver via the DALI interface It can also switch the output relay to control the mains supply to the lamp driver 2 The OLC switches the Line Output and communicates with the lamp driver via the DALI interfaces The monitor function reports on DALI information current mains voltage mains frequency power factor burning hours power and energy consumption of the connected lamp driver combination The OLC sets its status accordingly The SC read this information and communicates the actual values and fault conditions to the CMS The measured feedback data is optimal for released Philips drivers A default configured OLC will switch ON outp
9. of the device A drawing or list indicating which Neuron ID belongs to which installed OLC acts as an input for creating the Starsense telemanagement configuration LLC7030 Datasheet Outdoor Luminaire Controller DALI Power on the OLC Attention Apply mains power to the OLC only after it is mounted securely and has been wired as shown in the typical wiring diagram In case of an OLC that it is not yet commissioned at power up both red LEDs will come ON for 3 seconds The unit is fully operational and ready for commissioning and configuration after both red LEDs go OFF The green power LED should stay ON continuously indicating that power is applied and the OLC is running in the correct mode The OLC is now in its default configuration The safe guard mechanisms burning hours counter power up behavior and manual interfaces are operational In default configuration mode the OLC will always turn the light ON at power up The switch ON level can be pre configured through the OLC power up value Smart Power On feature is actually an intelligent inrush current limiter This would enable a replacement of the existing electromagnetics ballast with an electronic lamp driver and an OLC without adjustments in the power grid structure or the number of light points per circuit breaker MCB Safe guard mechanism SC commands have always priority on the operation of the OLC except the Daylight control based on photocell operation see
10. ontrol device o insulation between DALI and Mains circuit warning on product label and installation instruction EC 62386 101 excl clause 5 4 ntegrated power supply Max 8mA per DALI interface Short circuit proof DALI interface o mains protection According to IEC 62386 102 DALI and DALI 2 H 14 5V ot supported Packing data Type Box dimensions Qty mm LLC7030 OLC DALI 295 x 385 x 165 24 Photocell input Input Indicators Power LED green Service LED yellow Output LED red 2x Manual controls Service button yellow Test button orange Barcode code Back up scheduler Safety pre fuse requirement Housing Material Flammability Glow wire test Protection class Dimensions Weight Standards Safety Immunity Emission United States and other countries LONMARK SPONSOR Material cardboard 5 5 Suitable for magnetic relay type photocell without snubber This LED is on when the OLC has power This LED is normally off Blinking indicates that the application is in un configured state 2 red LEDs labelled and 2 which indicate the output state of DALI output and 2 Send Neuron ID Change output states and 2 100 50 OFF Code 28 Neuron ID Accuracy 0 7 Max value pre fuse 6 ATH Bayblend KU 2 1514 PC ABS Blend UL 94V 0 at 5mm thickness 850 C IP20 in any position IP22 in upright pos
11. s period the red LED blinks rapidly e Pressing the test button while the output is ON at a dimmed level will switch the output OFF Attention The OLCs output will be switched OFF after 15 minutes Power cycle the OLC to have the output automatically switched to its configured power up level Maintenance identification After maintenance has been done on an OLC press the test button for 4 seconds An identification message will be sent via Powerline and will be made visible in the CMS Neuron ID Each OLC has a unique fixed 48 bit identifier called Neuron ID The Neuron ID is printed on the three barcode labels placed on the front of the OLC which barcode readers can read OLC LLC7030 00 8222 740 39903 U 220 240V fy 50 60Hz P max 1000W t 2C OC CE IP 20 made in E U GE philips www philips com fi C Datasheet To prevent water traps do not mount the connectors upwards Housing provides insulation for class I DA is internally connected to Neutral Ni MN NNAM 000981379400 000981379400 OLC label Attention When the OLC is installed it is vital for the Starsense system operation that it knows the Neuron ID and the location
12. ut at maximum level on power up WwW The OLC has a backup scenario safeguard mechanism that can be configured in different ways see below Repeating The OLC is equipped with a power line transceiver which can repeat messages The SC monitors and controls the dynamic repeating functionality centrally If communication fails between the SC and a specific OLC another OLC can be designated dynamically by the SC which can repeat messages The SC will autonomously and continuously keep track of which OLC s can be reached directly and which ones require message repeating Mounting information The OLC is designed to be installed inside a luminaire but can also be mounted in the pole geartrays and separate boxes If the OLC is mounted inside a pole it may only be mounted upright The OLC may be mounted in any position if the enclosure is IP43 or above Please also refer to the installation instruction of the LLC7030 Note Check if feature is supported by the Central Management Software CMS 2 5 Released drivers The OLC has been tested with a very wide range of LED lamp driver types For the best overall system performance we do recommend the use of Philips LED lamp drivers Currently the lamp drivers released to interact with the DALI outputs of the OLC are e PHILIPS HID DV DALI 100 I50W SON CDM with lamps SON and CDM TT e PHILIPS HID DV DALI Xtreme driver with CPO Cosmopolis lamps 60 90 140 W e PHILIPS HF Regulator
Download Pdf Manuals
Related Search
Related Contents
Maytag MBF2256KEB2 User's Manual UBA-4204 User`s Manual - LKC Technologies, Inc. Chevrolet 2014 Cruze Supplementary Manual Istruzioni per il Dispositivo di Controllo Remoto del LuNAR Manuel d`Installation Klark Teknik DN9652 User's Manual Samsung SI-I8W041141CN 用户手册(LAMP USER MANUAL_ASIA) Avaya 3905 Digital Deskphone Quick Reference Guide Copyright © All rights reserved.