1. Example To set the required delay time at 7 seconds Simply press 00007 DTTRANSMIT 00007 OK WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com 16 COPYRIGHT 2010 WITURA CORPORATION SDN BHD Note The Delay Time is a 5 digits value range from 00000 99999 seconds Default 00004 seconds Step 8 Setting for Calling a Group of Administrator To program the unit to dial a certain group of numbers for PSTN AC failure or Auto Test you can press 29 to proceed CALL CALL 5 Example Setting the unit to dial the first 5 administrator Simply press 5 OK CALL 5 Step 9 Setting for Auto Test Step 9 1 Time Setting To setup time you can press 16 to proceed TIME TIME 08 30 00 Example To set the time at 8 30am Simply input digits and ended with WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com 17 COPYRIGHT 2010 WI TURA CORPORATION SDN BHD T y TIME 08 30 00 OK Step 9 2 Setting the Auto Test Report Time Section 1 The system has the function of sending the test report to the central station at the programmable time section The time is entered in 24 Hour format To program the auto test report time section 1 you can press 17 to proceed DSTM1 DSTM1 12 00 00 Example To set the auto test report time
2. Default Value 0 Note Once this function is turned on the attached fixed line phone will not ring when there is an incoming call Arm and Disarm Command via Voice Press 123456 to arm the system when WT 1010C2 answered the call Press 123456 to disarm the system when WT 1010C2 answered the call Note 123456 is a 6 digits password that is programmable by 0 function or PAWO command by SMS WT 1010C2 Programming Instructions Via SMS Programming the WT 1010C2 can also be done via SMS commands using your phone Any programming command sent by SMS must be in CAPITAL letters The fields between square brackets are parameters do NOT enter the square brackets When you send a command you will receive the answer for the first time even if your GSM number is not in the administrator list This happens because the WT 1010C2 recognizes any GSM number as administrator and answers to it Warning The administrator number must be programmed into the WT 1010C2 unit first via voice mode in order to use SMS programming mode 6 1 Time Setting To set the time you can send the following SMS command to the unit The time is entered in 24 Hour format Text Command SETM HH MM SS HH stands for 2 digits value Hour MM stands for 2 digits value Minute SS stands for 2 digits value Seconds Example WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com 27 COPYRIGHT 2010 WITURA CORPORATION SDN BHD
3. Input new password and ended with NEW PASSWORD 654321 OK 7 4 Inquire the status of the Recipients that will receive Alert Messages via Voice To inquire the status of the recipients you can press 19 to proceed RECIPIENTS 11111111 The status will be displayed on screen Press to turn back 7 5 Checking the Signal Strength via Voice To check the signal strength you can press 20 to proceed Y ll CSQ lt 23 gt The signal strength will be displayed on screen Press to turn back 7 6 Setting the Waiting Time for Engaged Call via Voice In the event the administrator has not answered the call or engaged it could take a while for the WT 1010C2 to call the next number You can shorten the time for every call by programming the waiting time Press 12 to proceed WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com 32 COPYRIGHT 2010 WI TURA CORPORATION SDN BHD W 010 U R MANUA WAIT TI ME WAIT TIME 20 Example To set the waiting time for 20 seconds Simply input 20 and ended with WAIT TIME 20 OK Note The waiting time is a 2 digits value range from 20 59 seconds Default 30 seconds 7 7 Setting Arm Delay Time Input 1 Only Input 1 can be programmed to arm after a preset time when the Arm button is pressed or Arm function is activated by fixed line phone To program th
4. Example To set the unit to ignore first 2 dialing digits Simply press 2 DEL NUM 2 OK Note The value is 0 4 Default 0 7 13 Adjusting the Speaker and Microphone Volume level via Voice To adjust the speaker and microphone volume level you can press 11 to proceed SPK MIC SPK 3 MIC 3 Example To adjust the speaker volume to 3 and microphone volume to 3 Simply press 33 SPK 3 MIC 3 OK WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com 36 COPYRIGHT 2010 WI TURA CORPORATION SDN BHD TO010C2 USER MANUAL Note Both SPK and MIC volume level range from 1 4 Default 1 Adjust the speaker and microphone volume to compatible with your alarm panel 7 14 Inquire the Software and Hardware Version of WT 1010C2 via Voice To check the software and hardware version of WT 1010C2 unit you can press 13 to proceed HW l lver SW 4 7 ver MW 3 2ver The information will be displayed on screen Press to turn back 7 15 Inquire All Programmed Administrator Number via SMS To inquire all the programmed administrator you can send the following SMS command to the unit Text Command ADM Example of Return Message 1 13256997049 2 15915325252 3 13456679988 7 16 Checking the Signal Strength via SMS EEEE To check the signal strength of the unit you can send the following SMS command to
5. USE1 Garage Opened 6 4 Editing the Inputs Alert Messages When No Pulse The Input Alert Message can be edited and programmed up to 50 characters You can change the displayed text by sending the following commands by SMS message to the unit Note Only support normal abc ABC English text no special characters Text Command USC NJ XXXXXX N stands for Input number 1 3 XXXXXX stands for alert message content Example If you want the alert message to display Garage Closed when input 1 triggered you would send the following SMS message to the unit USC1 Garage Closed Return Message USC1 Garage Closed 6 5 Output Settings 6 5 1 Activate Output Relay to Stay On for a Specific Time To activate the output relay you can send a text command via SMS specifying the number of seconds the output should stay on to the unit It is possible to set up to maximum of 99 999 seconds Text Command RLY N XXXXX N stands for Output number 1 3 XXXXX stands for 5 digits value The number of seconds 00000 99999 For example assume you want to turn on the output relay number 2 for 1 hour you would send the following SMS message to the unit RLY2 03600 WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com 29 COPYRIGHT 2010 WITURA CORPORATION SDN BHD VV 010C U R MANUA Return Message RLY2 03600 Sending the following SMS Message to unit would mean turn off the
6. W 010C U R MANUA When SETM 08 30 15 is applied the time 08 30 15 will be stored inside the WT 1010C2 memory Return Message SETM OK 6 2 Editing the Message Contents of Auto Test Up to 50 Characters The message contents can be edited and programmed up to 50 characters You can change the displayed text by sending the following commands by SMS message to the unit Note Only support normal abc ABC English text no special characters Text Command TSMS XXXXXX XXXXXX stands for message contents Example If you want the SMS Report to display Status Online you would send the following SMS message to the unit TSMS Status Online Return Message TSMS Status Online 6 3 Editing the Inputs Alert Messages When High Pulse The Input Alert Message can be edited and programmed up to 50 characters You can change the displayed text by sending the following commands by SMS message to the unit Note Only support normal abc ABC English text no special characters Text Command USE N XXXXXX N stands for Input number 1 3 XXXXXX stands for alert message content Example If you want the alert message to display Garage Opened when input 1 triggered you would send the following SMS message to the unit USE1 Garage Opened WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com 28 COPYRIGHT 2010 WITURA CORPORATION SDN BHD Return Message
7. DTI MEC ON amp amp OFF 1 To turn on this function simply press 1 To turn off this function simply press O WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com 19 COPYRIGHT 2010 WITURA CORPORATION SDN BHD R MANUA DTI MEC ON amp amp OFF 1 OK Default Value 0 Step 9 6 Enable Disable the generation of SMS Report for Auto Test To turn on this function you can press 28 to proceed DTI MEM ON amp amp OFF DTI MEM ON amp amp OFF 1 To turn on this function simply press 1 To turn off this function simply press O DTI MEM ON amp amp OFF 1 OK Default Value 0 Note Please refer to programming instructions via SMS for editing the message content of Auto Test Step 10 Setting for PSTN Failure To turn on this function you can press 30 to proceed PST ME OU AL CA1 CA2 PST ME 1 OU 1 AL 1 CA 1 CA2 1 Example Setting the unit to generate an Alert Message call the administrators generate a pulse V and sound the audible alarm when PSTN failed WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com 20 COPYRIGHT 2010 WI TURA CORPORATION SDN BHD N 010 R MANUA Simply input 11111 PST ME 1 OU 1 AL 1 CA 1 CA2 1 OK Description ME stands for generation of SMS when PSTN failed Default 0 OU stands for generation of pulse V at P
8. WT 1010C2 GSM ALARM SYSTEM User Manual MTOR WITURA CORPORATION SDN BHD N 010 U R MANUA 1 Getting Started esras ena a a Ses eee ected Se eee a e rA LL in thesPacKa ging trcccicvevacciodlccechevenateeatesstane paced a a ined r E a T 1 2 Viewing the WT LOLOC2 sie sce cctesisaniciel teniedin saves A a i R R E E aa a RaR EEE 2 Introduction to WT 1010C2 GSM Alarm SySteM s s ssmsmsnimiuinininininininininiuininiminininsnimininineminininim emen D 2 1 General OvervieW s s mimeneasa 3 Main Features of the W110 1L0C2 w 6 cessed cieiacnie tailed ee eee eres eae ere A aE E A lnstallations NStructions 2csese 6 34 hecedeceee e dedeedet os eee a a deel adi dlsdede mend E 4 1 External Connections Diagram acscarcieseterceedsenseeeueresacetaqeenicveusinudiwndentaye E a einna Fees 4 2 Wiring Diagram A Main Unit ssssasssnsnsusniuinininimininininimininimsrininininiminininiminm ens 4 3 Wiring Diagram B DB15 Female Cable 2 2 2 cece cece ene c ccc ene nec en ene mem ene neme mene ememeneaememenemememeae AA DOSE PtlON cei ieee a cabana E a eemaeere seh cae mnehame lenndne eure a a EE 4 5 WT 1010C2 Inputs amp Outputs Wiring INStrUCtHONS s ssscscssnininininininininininininininininiuinineninin 4 6 installifig the SlM Cardsicrisieecscegecense soci cadsacked oeapeccieiaeendy wen neievesnucseusedrererd cnbeedantewcegadis 4 7 Power up the W110 1L0C2 seisnema ieee lel eect ie eae Ae onl AeA ies alte Ae oa St 4 8 Dia
9. 7 10 Activate Output Relay to stay on for a specific time via Voice To activate output relay 1 to stay on for a specific time you can press 21 to proceed RLY1 RE RLY1 00050 RE 1 Example To activate relay 1 to stay on for 50 seconds and with SMS reply from the unit after relay has turned off Simply input 000501 RLY1 00050 RE 1 OK Note RE stands for generation of SMS when relay off value ON 1 or OFF 0 You may continue to activate relay 2 or relay 3 by pressing 22 or 23 7 11 Setting the Alarm Time for Audible Alarm via Voice To set the alarm time for audible alarm you can press 33 to proceed ALARM ALARM 03600 Example To set the audible alarm to sound for 1 hour when triggered Simply press O3600 v ALARM 03600 OK Note The alarm time must enter in 5 digits range from 00001 99999 Default 00010 seconds WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com 35 COPYRIGHT 2010 WI TURA CORPORATION SDN BHD 7 12 Setting the WT 1010C2 to ignore the front dialing digits when dialing the Administrator via Voice This function is useful when the WT 1010C2 is connected to the PABX system where Access Digits are required for Extension Line Centrex Line To set the unit to ignore the front dialing digits you can press 44 to proceed DEL NUM DEL NUM 2
10. Default 0 CA2 stands for calling the administrators when AC connected Default 0 Value ON 1 or OFF 0 Auxiliary Power Down Output Facility via PI N7 In additional to the alarm and text alert on AC failure the system also has a second permanent V output continuously supplied from the battery backup via PIN7 output of the unit which will remain available for the period of AC unavailable Auxiliary V Output when AC Failure PIN7 Note Power Down Output facility can be used on alarm panel for alert notification Step 12 Setting for Overcoming GSM Jammers amp GSM Tower Failure Step 12 1 Enable Disable the function of Activate Output Relay 1 when GSM Jammers is detected To turn on this function you can press 38 to proceed NETWORK ON amp amp OFF NETWORK ON amp amp OFF 1 To turn on this function simply press 1 To turn off this function simply press O WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com 22 COPYRIGHT 2010 WITURA CORPORATION SDN BHD T y NETWORK ON amp amp OFF 1 OK Step 12 2 Setting the Parameter for Network Failure To set the parameter you can press 39 to proceed NETDT1 RLY1 NETDT1 05 RLY1 05 Example To set the network failure time for 5 seconds and the turn on time of Relay 1 for 5 seconds Simply press 0505 NETDT1 05 RLY1 05 OK Descriptio
11. Pick up the handset or press hands free press 123456 to enter programming mode If the password has entered correctly you should see HAND FREE displayed on WT 1010C2 screen Now you may proceed with programming settings ENTER SETTING When pick up the handset ENTER OK SETTING Password entered correctly HAND FREE Programming Mode WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com 13 COPYRIGHT 2010 WITURA CORPORATION SDN BHD Step 2 Reset the WT 1010C2 Unit To reset the unit you can press 15 to proceed REST ON amp OFF REST ON amp OFF 1 Then press 1 to reset REST ON amp OFF 1 OK Note It is advised that you should reset the WT 1010C2 unit before proceeding to the below programming section Step 3 Programming the Administrator Continue pressing 1 to start programming the administrator number 1 TEL 1 TEL 13232353646 1 Enter administrator number 13232353646 for example and ended with i TEL OK Number has programmed successfully You may continue to program administrator number 2 3 4 5 6 7 and 8 by pressing 2 g 3 4 p Bx 6 7 8 WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com 14 COPYRIGHT 2010 WI TURA CORPORATION SDN BHD Step 4 Setting the Recipient
12. the unit Text Command CSQ WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com 37 COPYRIGHT 2010 WI TURA CORPORATION SDN BHD Example of Return Message CSQ lt 28 gt 7 17 Checking the Current Time Status via SMS To check the current time you can send the following SMS command to the unit Text Command ASTM Example of Return Message TI ME 01 35 50 7 18 Changing the Programming Mode Password via SMS It is possible to change the login password by sending the following SMS command Text Command PAW O XXXXXX XXXXXX stands for 6 digits New Password Example To change the password to 654321 you would send the following SMS command to the unit PAWO 654321 Return Message PAWO OK 7 19 Reset the WT 1010C2 unit via SMS To reset the unit you can send the following command by SMS to the unit Text Command REST XXXXXX XXXXXX stands for 6 digits password based on PAWO Default 123456 and it can be changed anytime WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com 38 COPYRIGHT 2010 WITURA CORPORATION SDN BHD W 010C2 USER MANUA Return Message REST OK 7 20 Inquire the Status of Inputs PSTN and AC To inquire the status of inputs PSTN and AC you can send the following SMS command to the unit Text Command CTC Example of Return Message AC 1 PSTN 0 INPUT2 1 __ INPUT3 0
13. Input 2 triggered Technical Specifications Environment temperature 0 50 C Relative humidity 10 95 Air pressure 86 106kpa Environment yawp lt 60dB A Working frequency GSM900MHz GSM1800MHz Stability of frequency better than 2 5PPM Signal sensitivity 103dBM Transmit power lt 2w Power 220v 15 AC 10 Input Voltage Tolerances 1 20VDC 11 The max distance between terminal and telephone 100M Ot Oe ae A WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com 39 COPYRIGHT 2010 WITURA CORPORATION SDN BHD JN D10 USER MANUA Warranty Witura Corporation Sdn Bhd guarantees all WT 1010C2 GSM Fixed Wireless Terminal against defective parts and workmanship Witura Corporation Sdn Bhd shall at its option repair or replace the defective equipment upon the return of such equipment to any Witura branch This warranty applies ONLY to defects in components and workman ship and NOT to damage due to causes beyond the control of Witura such as incorrect voltage lightning damage mechanical shock water damage fire damage or damage arising out of abuse and improper application of the equipment Note Wherever possible return only the PCB to Witura Service Centres DO NOT return the enclosure The WT 1010C2 is a product of Witura Corporation Sdn Bhd And is manufactured by Shenzhen Witura Telecommunications Co Ltd WARNING For safety reasons only connect equipment with a tele
14. Note Installing the SIM Card Please be sure the initial 4 digit PIN code of SIM card is disabled This can be done by placing it in an unlocked Mobile phone and first checking if the SIM requested any PIN code If this is the case the PIN code can be disabled using the security settings on the phone Warning The WT 1010C2 identifies only 3V SIM Card l p EA Proceed as follows WU 1 Slide back the SIM door and lift it up 2 Slide the SIM card into the SIM door making sure that the clipped corner of the SIM card lines up with the clipped corner of the SIM holder 3 Close the SIM door 4 Slide the SIM door to lock the SIM card in place 4 7 Power up the WT 1010C2 When power up the WT 1010C2 it will display as below LOADI NG gt gt gt gt gt WAITING When the terminal is ready to use it will display as below Yi l gp Pwer D j WT 1010 D battery D Note Whenever the WT 1010C2 fails to logon to network or fails to detect the SIM card it will restart automatically until it has detected the SIM card or successfully logon to network WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com 11 COPYRIGHT 2010 WI TURA CORPORATION SDN BHD WT 1010C2 USER MANUAL 4 8 Dialing a number from the attached telephone set Connect to TELL After the GSM module is connected to the GSM network an attached fixed line phone can be used to make calls If you pick up th
15. Waiting Time for Engaged Call via Voice E E EE A E T 7 7 Setting Arm Delay Time Input 1 Only s s m ssninsminininimiasninininineninimeninininimeninimiminenimemen mnn 7 8 Enable Disable System Power Up SMS Notification 2 0 cece neem een scene mememenemememsmenenemsnnnemenenan J 7 9 Enable Disable System Armed SMS Notification sssescmemercmcncninininininineninrnrniarnininininrnrnn DA 7 10 Activate Output Relay to Stay On for a Specific Time via Voice 235 7 12 Setting the WT 1010C2 to Ignore the Front Digits When Dialing the Administrator via sein DO 7 13 Adjusting the Speaker and Microphone Volume Via VOICE cnc cn seen eeeememementnemememenenemensnenens SO 7 14 Inquire the Software and Hardware Version of WT 1010C2 Via VOICE eect mem emenenen eT 7 15 Inquire All Programmed Administrator Number via SMS s s ssssussininininiuiurnimininininininininsnrnrarn SD 7 16 Checking the Signal Strength Vid SMS 2 0 etc een cere eeseeneneeneneneneneninenenineneninenininene DD 7 17 Checking the Current Time Status via SMS 2 0 cence cece ener enn m ene nn en emimnemeniminememiminenens DO 7 18 Changing the Programming Mode Password via SMS s assmsssninienininininininininininiuininimininsnrnrarn DO 7 19 Reset the WT 1010C2 Unit via SMS 2 2 ein cecceenene eee iaia a a aa i aa ara u iaai DO 7 20 Inquire the Status of Inputs PSTN and AC s sessssmsninsniusninininininininiminiuinininimsniuinininimeninrnrn oO 8 Technical Specifications 2cscci
16. can be programmed to send a SMS to a programmable cell phone number to notify the user that the PSTN line has been cut off or unavailable 6 Itis possible to arm disarm the unit remotely via remote control SMS or phone call Alternatively it also can connect to the basic telephone to perform arm disarm 7 Three digital inputs The system has the function to send SMS and call to the user in the event of input triggered For example Zone 3 connected to an electric door when there is intruder or the electric door is open illegally WT 1010C2 will receive WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com COPYRIGHT 2010 WI TURA CORPORATION SDN BHD N 010 U RP MANUA short circuit impulse on Zone 3 and automatically sends a signal to the pre set number and notify the owner 8 Three remote control outputs These open collector outputs that can sink max 300ma per output can be turned on and off remotely through a SMS or phone call Remote control will be reachable by sending a SMS or phone call with a certain command For example SMS Call in to switch on lighting air conditional generator sensor or other equipment 9 Standby rechargeable battery to prevent power failure or electricity cut off by intruder The GSM will function as normal when no electricity supply LCD display to check the GSM signal strength and battery capacity 10 Low power consumption uses 30mA while in idle state and 260mA when tra
17. that will receive Alert Messages The unit can send text alerts to 1 or all 8 of the programmed administrator s numbers To do this setting you can press 18 to proceed SECT SECT 11111111 Example To turn on this function for all recipients Simply input 11111111 SECT 11111111 OK Note The input for this setting is an 8 digits value ON 1 or OFF 0 only Each of them represents administrator 1 8 Default Value 10000000 Step 5 Programming the Area Code To program area code you can press 9 to proceed NEW AREA NEW AREA 03 Enter area code 03 for example and ended with NEW AREA 03 OK Area code has programmed successfully WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com 15 COPYRIGHT 2010 WITURA CORPORATION SDN BHD Note It is possible to program up to 4 digits Step 6 Setting the Function of Adding Area Code when Transmitting an Alarm To turn on off this function you can press 14 to proceed AREA ON amp amp OFF AREA ON amp amp OFF 1 To turn on this function simply press 1 To turn off this function simply press O AREA ON amp amp OFF 1 OK Default Value 0 Step 7 Setting the Delay Time for Transmitting a Dialing Number To set the delay time you can press 34 to proceed DTTRANSMIT DTTRANSMIT 00007
18. 212 ceeceanenee andor esa a aa a E iene id ea n a a 7 11 Setting the Alarm Time for Audible Alarm via VO Ce s s ssmsmsnsuiuinininininiuinininininiminininsninimininins VOICE eosar a E O A a a a E WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com COPYRIGHT 2010 WI TURA CORPORATION SDN BHD R MANUA 1 Getting Started 1 1 In the Packaging aa Z oe eo Please make sure the following items are included in the packaging Name Quantity Unit WT 1010C2 Main Unit 1 set Telephone line 1 set DB15 F cable 1 set Power adapter 1 set 5m GSM terminal antenna 1 set User s Manual 1 CD 1 2 Viewing the WT 1010C2 ANTENNA The antenna must be well connected before turn on the terminal NETWORK POWER INDICATOR INDICATOR RED GREEN The indicator is The indicator is illuminated when mains illuminated when the power is present terminal is connected to GSM Network WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com COPYRIGHT 2010 WITURA CORPORATION SDN BHD N 010 U R MANUA Introduction to the WT 1010C2 GSM Alarm System The WT 1010C2 GSM Terminal is a wireless communicator for alarm and fire panels that uses the cell phone network GSM to transmit alarms and other panel event The module checks the status of the PSTN line and in case the PSTN line becomes unavailable the WT 1010C2 GSM emulate the line signal to the panel At this time the panel wil
19. 5 Technical Support Technical witura com 24 COPYRIGHT 2010 WITURA CORPORATION SDN BHD N 010 R MANUA IN1 OP CL AL CA1 CA2 IN1 OP 1 CL 1 AL 1 CA1 1 CA2 1 Example Setting the input 1 to generate an SMS call the administrators and sound the audible alarm when it triggered Simply input 11111 IN1 OP 1 CL 1 AL 1 CA1 1 CA2 1 OK Description OP stands for generation of SMS when input triggered Open Default 0 CL stands for generation of SMS when input triggered Close Default 0 AL stands for sounding the audible alarm when input triggered Default 0 CA1 stands for calling the administrators when input triggered open Default 0 CA2 stands for calling the administrators when input triggered close Default 0 Value ON 1 or OFF 0 You may continue to activate Input 2 Input 3 and Input 4 functions by pressing 25 or 26 Note Please refer to programming instructions via SMS for editing the Input Alert messages Step 14 Arm and Disarm the System Via Fixed Line Phone To arm the system you can press 10 to proceed ARM OR DISARM ON amp amp OFF WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com 25 COPYRIGHT 2010 WITURA CORPORATION SDN BHD N 010 U R MANUA ARM OR DISARM ON amp amp OFF 1 Example To arm the system simply press 1 To disarm the system
20. IN15 when PSTN failed Default 0 AL stands for sounding the audible alarm when PSTN failed Default 0 CA1 stands for calling the administrators when PSTN failed Default 0 CA2 stands for calling the administrators when PSTN connected Default 0 Value ON 1 or OFF 0 Auxiliary PSTN Failure Output Facility via PIN15 In additional to the alarm and text alert on PSTN failure the system also has a permanent V output continuously supplied from the unit via PIN15 output which will remain available for the period of PSTN unavailable Auxiliary V Output when PSTN Failure PIN15 Note PSTN Failure Output facility can be used on alarm panel for alert notification Step 11 Setting for AC Failure To turn on this function you can press 31 to proceed ADC ME AL CAI CA2 ADC ME 1 AL 1 CA1 1 CA2 1 Example Setting the unit to generate an Alert Message call the administrators generate a pulse V and sound the audible alarm when AC failed Simply input 1111 WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com 21 COPYRIGHT 2010 WI TURA CORPORATION SDN BHD N 010 R MANUA ADC ME 1 AL 1 CA1 1 CA2 1 OK Description ME stands for generation of SMS when AC failed Default 0 AL stands for sounding the audible alarm when AC failed Default 0 CA1 stands for calling the administrators when AC failed
21. achable by sending a SMS with a certain command Note When sending normal SMS with command below the WT 1010C2 will turn On Off the output relay and reply a message of output has turned On Off to a programmable phone numbers ZONE1 IN1 ZONE2 IN2 ZONES I N3 Inputs Connect ZONE1 ZONE2 and ZONE3 to inputs panel when there is a short circuit impulse on ZONE1 ZONE2 ZONE3 the WT1010C2 is possible to send SMS to a programmable phone numbers For Example ZONE3 is connected to an electrical door when there is intruder or the electrical door is opened illegally WT1010C2 will receive short circuit impulse on ZONE3 and will automatically send a signal to the monitoring station and also send a SMS to notify the owner WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com COPYRIGHT 2010 WITURA CORPORATION SDN BHD N 010 R MANUA ttyl input yO INPUT Inputs and Outputs Wiring Diagram Permanent V Output Facility There is a permanent V output when the WT 1010C2 is power on This output is available on the connection PIN8 and ground on the main board The output voltage is according to power supply used on WT 1010C2 It can be used to power on other facility or device WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com 10 COPYRIGHT 2010 WITURA CORPORATION SDN BHD N 010 L R MANUA 4 6 Installing the SIM Card
22. at 12 00pm Simply input digits and ended with DSTM1 12 00 00 OK Step 9 3 Setting the Auto Test Report Time Section 2 The system has the function of sending the test report to the Administrator at the programmable time section The time is entered in 24 Hour format To program the auto test report time section 2 you can press 42 to proceed DSTM2 DSTM2 18 00 00 Example To set the auto test report time at 18 00pm Simply input digits and ended with WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com 18 COPYRIGHT 2010 WITURA CORPORATION SDN BHD JN D10 USER MANUA DSTM2 18 00 00 OK Note Skip this setting if only 1 time section is needed Step 9 4 Setting the Auto Test Report Time Section 3 The system has the function of sending the test report to the Administrator at the programmable time section The time is entered in 24 Hour format To program the auto test report time section 3 you can press 43 to proceed DSTM3 DSTM3 23 59 00 Example To set the auto test report time at 23 59 pm Simply input digits and ended with DSTM3 23 59 00 OK Note Skip this setting if only 1 time section is needed Step 9 5 Enable Disable the function of dialing the programmed Administrator number for Auto Test To turn on this function you can press 27 to proceed DTI MEC ON amp amp OFF
23. communications compliance label This includes customer equipment previously labelled permitted or certified WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com 40 COPYRIGHT 2010 WITURA CORPORATION SDN BHD
24. e delay time you can press 45 to proceed ARM TI ME ARM TIME 30 Example To set the arm delay time for 30 seconds Simply input 30 and ended with OK Note The Arm Time is a 2 digits value range from 00 59 seconds Default 00 seconds WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com 33 COPYRIGHT 2010 WITURA CORPORATION SDN BHD W 010 Uk R MANUA 7 8 Enable Disable System Power Up SMS Notification The system is able to generate SMS notification whenever the WT 1010C2 is turned on To enable this function you can press 46 to proceed POWER UP MSG ON amp amp OFF POWER UP MSG ON amp amp OFF 1 To enable this function simply press 1 To disable this function simply press O POWER UP MSG ON amp amp OFF 1 OK Default Value 0 7 9 Enable Disable System Armed SMS Notification The system is able to generate SMS notification whenever user armed the WT 1010C2 To enable this function you can press 47 to proceed ARM MESSAGE ON amp amp OFF ARM MESSAGE ON amp amp OFF 1 To enable this function simply press 1 To disable this function simply press O ARM MESSAGE ON amp amp OFF 1 OK Default Value 0 WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com 34 COPYRIGHT 2010 WITURA CORPORATION SDN BHD N 010 Uk RP MANUA
25. e phone you will hear a dial tone Simply dial the number you want to call as if you are dialing from a normal fixed line phone You can also dial the WT 1010C2 unit s phone number from another phone and its attached phone will ring as a normal landline phone would If there is a busy tone on the attached telephone set either the line you are calling is busy or the GSM communicator is busy with previous communication at that moment for example data transfer to the monitoring station Note Some telephone sets are sensitive to the GSM radio signal For this reason you may hear a characteristic noise in the telephone receiver when calling If the noise is disturbing change the location of the phone set try to keep it as far as possible from the WT 1010C2 unit antenna Usually it is possible to find a suitable location for the phone with minimal level of interference WT 1010C2 Configuration I nstructions Via Fixed Line Phone 5 1 Introduction The WT 1010C2 can be programmed manually by a connected normal telephone WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com 12 COPYRIGHT 2010 WITURA CORPORATION SDN BHD WT 1010C2 USER MANUAL Connect to TELL Note Before commencing programming it is advisable to read the below programming setting instructions thoroughly To start with programming user must plug in a normal single line phone to TEL1 Port 1 Step 1 Enter Programming Mode
26. he Function of Dialing the Programmed Administrator Number for Step 9 6 Enable Disable the Generation of SMS Report for Auto TeSt 0a senenenen ene enens 20 Stepl0 Setting for PSTN Failure cruisera aea aa eana araisa 20 Stepll Setting for AC Faillresa c oseiaiendseecenteneanadveumesadieiecenareebsesedraeneeespnccietanencressstreiar 2 L Step12 Setting for Overcoming GSM Jammers amp GSM Tower Failure scence eee eceeeneneenemenemene 2d AUtO TeStidecetevintudsctiedsctet Gusts ccs Sie den aE E eco EENE Step 12 1 Enable Disable the Function of Activate Output Relay 1 when GSM Jammers is Step 12 2 Setting the Parameter for Network Failure ececeeweneee mem emenenemememenemememens 23 Step 12 3 Enable Disable the Function of Activate Output Relay 2 when GSM Tower Pailire facet secs elle enne ce ented ieee oct aed eee 2S detected 2 2220 eke Sathoemsetnaee eases eet edeete endo a a aS WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com COPYRIGHT 2010 WITURA CORPORATION SDN BHD N 010 U R MANUA Step 12 4 Setting the Parameter for GSM Tower FailUre s ssssususncninrniurnrniuininiurniurnin 24 Step13 input Settings 1 24 ease ee a a a eee E E E a a a 2D Step14 Arm and Disarm the System via Fixed Line Phone s ssssasssnrninininininiuinininininiuininenrnia 2D Step15 Setting the Automatic Call Answering Feature s s ssssssmcmininininininininiuinininininiusnrnea snra 20 6 WT 1010C2 Programming Inst
27. l dial out using the GSM cell phone network to communicate with the receiver at the monitoring station and transmit the alarms 2 1 GENERAL OVERVIEW Mobile Alarm sent j Specific Data SMS Mobile Alarm sent j Specific Data SMS Receiver La Transmission i Standard via PSTN Line Alarm Receiver Dialer Reception on Processing by Standard Receiver operator WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com COPYRIGHT 2010 WITURA CORPORATION SDN BHD NV 010 U Reception on Mobile Mobile Reception on Specific DATA Processing by Receiver operator Specific Data SMS Monitoring Reception on Standard Receiver Main Features of the WT 1010C2 1 Panel compatibility Allows any contact ID alarm panel to transmit alarms over GSM using the GSM voice channel 2 Works over the GSM cell phone networks Units can be used wherever there is cell phone coverage 3 Telephone line backup WT 1010C2 give priority to the lowest cost network WT 1010C2 uses the telephone line as the main transmission line and uses the GSM voice channel as backup 4 Auto restart system It can continuously monitor the system status of its own When there is a problem with the SIM card or the module is not working properly it will automatically restart the system 5 Sends text messages to user programmable cell phone number SMS The WT 1010C2
28. ling a Number From the Attached Telephone Set esa seenen ese enemesemememesememem cenemeseaememesen ene 5 WT 1010C2 Configuration Instructions Via Fixed Line Phone eds WMtFOdUCTION caiSteraucnatecdenuncnsoanansanaeacianormantmaatabaimdhansanuimiqdconsuen ie E a EARN Stepl Enter Programming Mode esorare aae aaa e e a E AES EE Step2 Reset the WT LOL0C2 Uniti cciete esis eae nd ene eects lee E E Step3 Programming the AdMinN StratOr s s ssssniusninininrniuinininininiurninimsninininimimsninrnininensnimenenmn Step4 Setting the Recipient that will receive Alert MeSSageS n s ssscmsncninininiuininininiuininininrniusnrns Step5 Programming the Area Code caceeecs cn ecemcsrew enemas ene mssnea en emasreaneaenemasteaenemasnea en emsaea enemas Step6 Setting the Function of Adding Area Code when Transmitting an Alarm acese cen n enn LO Step7 Setting the Delay Time for Transmitting a Dialing NUMDEe ose ee cence ese ene mene n ene mennemenes Step8 Setting for Calling a Group of AUMINIStrator 2 etree ene enen eminent memnenenememeneemememenemen 7 Step9 Setting for Auto Test Step 9 1 Time Setting Step 9 2 Setting the Auto Test Report Time Section 1 0 cent en ene enemteemenemenemenemene LS Step 9 3 Setting the Auto Test Report Time Section 2 0 ete tn etn enim em eminneenenen LO Step 9 4 Setting the Auto Test Report Time Section 3 0 0 ncn ee ene cnet emenenenenenene LO Step 9 5 Enable Disable t
29. n NETDT1 stands for network failure time range from 00 59 seconds Default 6 seconds RLY1 stands for turn on time of Relay 1 when network fails 00 59 seconds 00 means RLY1 will stay ON permanently Step 12 3 Enable Disable the function of Activate Output Relay 2 when GSM Tower Failure To turn on this function you can press 40 to proceed NO SIGNAL ON amp amp OFF WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com 23 COPYRIGHT 2010 WITURA CORPORATION SDN BHD N 010 R MANUA NO SIGNAL ON amp amp OFF 1 To turn on this function simply press 1 To turn off this function simply press O NO SI GNAL ON amp amp OFF 1 OK Step 12 4 Setting the Parameter for GSM Tower Failure To set the parameter you can press 41 to proceed NETDT2 RLY2 NETDT2 06 RLY2 10 Example To set the network failure time for 6 seconds and the turn on time of Relay 2 for 10 seconds Simply press 0610 NETDT2 06 RLY2 10 OK Description NETDT2 stands for network failure time range from 00 59 seconds Default 6 seconds RLY2 stands for turn on time of Relay 2 when network fails 00 59 seconds 00 means RLY2 will stay ON permanently Step 13 Input Settings Turn on the function of Inputs To turn on the function of input number 1 you can press 24 to proceed WT 1010C2 USER MANUAL Rev 3
30. nsmitting an alarm 11 Wall mounting enclosure available The WT 1010C2 units can be installed inside the alarm panel or inside its own wall mount enclosure 4 Installation Instructions Note It is essential that you read the step by step instructions fully prior to installing and programming the unit 4 1 External Connections Diagram OUTPUT Connect the RS232 DB15 female cable to the terminal for controlling outputs and inputs TEL PORT 1 ALARM INPUT TEL PORT 2 Connect to Alarm Panel also Connect to PSTN Line function as Phone Input ANTENNA PORT ON OFF SWITCH POWER PORT Connect the provided Turn On or Off the Connect a 12V Power antenna to the Terminal Supply to the Terminal Terminal WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com COPYRIGHT 2010 WITURA CORPORATION SDN BHD W 010C2 USER MANUA 4 2 Wiring Diagram A Main Unit Connect the Alarm Transmission antenna to via DTMF SMS Connect to the GSM e eee eb Module _ r Connect to the Internal L Battery General Input for Connect to a aon 12V 24 PANAM palate RS232 DB15 Port anel Power Connect to Inputs panel Supply amp additional remote controlling outputs 4 3 Wiring Diagram B DB15 Female Cable Audible Siren Output Audible Siren Auxiliary N A Output when AC Failed GND PIN1 ROE N A PIN Permanent Output when power on sats fae Auxiliar
31. output relay number 1 RLY1 00000 6 6 Arm and Disarm the System Via SMS It is possible to arm and disarm the system by SMS You can send the following text command to unit Text Command DARM X X stands for ON 1 or OFF 0 value Example To arm the system you can send the following text message to the unit DARM 1 Return Message ARM To disarm the system you can send the following text message to the unit DARM 0 Return Message DISARM WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com 30 COPYRIGHT 2010 WITURA CORPORATION SDN BHD 7 Miscellaneous Settings 7 1 Inquire All Programmed Administrator via Voice To inquire all administrator numbers you can press 32 to proceed ADMIN 1 1234567890 All the administrator numbers will be displayed in sequence 7 2 Deleting the Administrator Number via Voice Example To delete the programmed administrator number 1 you can press 1 to proceed TEL 1 TEL 1 Simply press to delete v OK DEL1 7 3 Changing the Programming Mode Password via Voice To change the 6 digits programming mode password you can press 0 to proceed WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com 31 COPYRIGHT 2010 WITURA CORPORATION SDN BHD I010C2 USER MANUAL NEW PASSWORD NEW PASSWORD 654321
32. ructions Via SMS s s s ssscninsniuiurniuinininininimininininiminininininiuininrnsnn 2 6 1 mime Settings neei Sia see eine eee het Binh eee ies eee eee aT 6 2 Editing the Message Contents Of Auto TeSt 0 enter n em enen ene memnenememinrnememinrnememimintnemeninenemens 2O 6 3 Editing the Input Alert Messages When High PulSe ncncnenenenenenemenewenenemesemenememesemememenn QO 6 4 Editing the Input Alert Messages When No PulSe s ssssnsusniuinininininiuinininininiuinininsnrniuinininsa sens DO 6 5 Output Settings ensede r aire leaerei ease a a a aa e aa aae ena aaa 6 5 1 Activate Output Relay to Stay on for a Specific TiMe s sessarssnissnininininiuinininrnininineniusn 29 6 6 Arm and Disarm the System Via SMS 0 nseceen ewes em emenenenemensnenememsnenememinenememinsnenemensnsnemens sO 7 Miscellaneous Settings cosesssscusnengvieidensds cited setegeedsaneas ee oceaedsd a aiaa a aaa a a de rai eira a 0 7 1 Inquire all Programmed Administrator via VO CE s s ssssarusniruiuininininiuinininininiuininimsniuinininmemsniurarn L 7 2 Deleting the Administrator Number via VOCE s s ssssissisrmsismmerri sisi sssrrerurnrmrurnrurnrnrnrnrn ee L 7 3 Changing the Programming Mode Password via VO Ce s sesescsisnininininininininininineninineninrneninrn o L 7 4 Inquire the Status of the Recipients that will receive alert messages Via VoOiCe s s ssscusucnruruinrninin nem 7 5 Checking the Signal Strength via Voice R NA E E E E E A E A 7 6 Setting the
33. simply press 0 ARM OR DISARM ON amp amp OFF 1 OK System armed successfully Note In Armed mode the WT 1010C2 can generate SMS alerts alarms and dialing the administrator numbers when the inputs triggered Auto Test PSTN failed or AC failed Alarm Indicator When dialing the Administrator numbers When Input 1 triggered it will generates Beep continuous sound When Input 2 triggered it will generates Beep x 2 continuous sound When Input 3 triggered it will generates Beep x 3 continuous sound When AC failed it will generates Beep x 5 continuous sound When PSTN failed it will generates Beep x 6 continuous sound When Auto Test it will generates Beep endless sound Step 15 Setting the Automatic Call Answering Feature The WT 1010C2 can be programmed to answer all incoming calls automatically even there is no fixed line phone attached to it When the call is answered it allows the owner to arm or disarm the system by entering a command from their phone s keypad To turn on this function you can press 35 to proceed AUTO ANSWER ON amp amp OFF AUTO ANSWER ON amp amp OFF 1 To turn on this function simply press 1 To turn off this function simply press O WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com 26 COPYRIGHT 2010 WITURA CORPORATION SDN BHD VV 010C U R MANUA AUTO ANSWER ON amp amp OFF 1 OK
34. y S Output when Teta 0 PSTN Failed PIN15 een 1 Output 3 een PIN14 WT 1010C2 USER MANUAL Rev 3 5 Technical Support Technical witura com COPYRIGHT 2010 WITURA CORPORATION SDN BHD VV 010 ru R MANUA 4 4 Description Antenna connect the antenna to the GSM module place the antenna as far as possible from the WT 1010C2 and do not leave any coiling of the antenna cable to avoid radiant interference SIM Card disable the PIN code and set it to 1234 default For Transmitter Mode Data or SMS as with any transmitter it requires an identifier receiver telephone numbers etc refer to the complete information on Programming page Line Input connect the line input to the PSTN or ISDN network Outputs Back Up Mode connect the RS232 DB15 to additional remote controlling outputs Alarm Input connect the input to output of the Alarm Panel Control Panel Power Supply connect to a 12V power supply Operating State Approximately 20s after power up check the operating state indicated by the Power LED the LED is steady during power up phase and then blinks when the connection to the GSM network is established The Signal indicator LED will stay lit whenever there is signal WT 1010C2 Inputs and Outputs Wiring Instructions RLY1 OUT1 RLY2 OUT2 RLY3 OUT3 Remote Controlling Outputs These open collector outputs can be turned on and off remotely through a SMS Remote control will be re