Home
User manual - Pro Audio
Contents
1. Named parameters are indicated by a number in square brackets For Example bl 1 source indicates a parameter after bl and before source and that the text 1 should be replaced by an appropriate value in this case would be the number of zone for example bl 0 source BlueLine command devices OSC Address OSC Type OSC RARE Saves the current memory to be restored through a bl 11 push None POP command bl 1 pop none Rein the stored settings workigy Blueline 43 USER MANUAL BASIC NOTIONS ABOUT LAN NETWORK A local area network LAN is a group of devices connect in a located area in order to communicate between them and share resources like for example printers Datas are sent in packets and for this broadcasting can be used several technologies The most common LAN technology is Ethernet which is specified in the IEEE 802 3 standard Ethernet uses a topology in star where all single nodes devices are connected between them trough an active network device like a switch The number of devices connected to a LAN can oscilate between two or several thousands The physical broadcasting way for a wired LAN includes twisted pair cables or optical fiber A twisted pair cable disposes of 8 cables 4 pairs of twisted cables and used RJ 45 connectors and sockets The maximum length of a twisted pair cable is 100 m while for optical fiber the maximum length varies between 10 km
2. Indicates the mute value of the selected channel in 2 bl 1 vol 21 iT Mute Channel can be mute iF Channel O 1forLyR master 1forL 2 forR iT iF iT iF iT iF bl 1 zone bl 1 zone 2 name bl 1 vol 2 bl 1 mode RECIVERS ONLY Sets the working mode of the device It may be O O 0 for Dual oue 1 for Single 2 for Mono SENDERS ONLY Sets the format of the audio data to be transmitted It may be 0 for ADPCM Audio Format O 1 for PCM 6 for MP3 Other values reserved and should not be used Sets the value of the GPO specified in 2 The GPO GPO Status index starts at 1 bl 1 format bl 1 gpo 2 bl 11 gpi 2 Reads the value of the GPI indicated in 2 GPI index starts at 1 GPI Status The GPIs are read only so that a write to this address does nothing Reads the value of the alarm pin Alani Status GPIs like it is read only workigy Blueline 46 USER MANUAL bl 1 alarm BASIC NOTIONS ABOUT IP PROTOCOL IP protocol is a software protocol which has not connection with network hardware the main feature for network interlink This protocol allows the network interlink independently from the hardware IP addresses are 32 bit and divided in 2 fields IP network identification and Host identification from this network IP adresses are represented in decimal format 4 octos separated by decimal dot instead of to ex
3. Firmware Version v 1 30 1 NETWORK SETTINGS Device Name BLR 2 Lite e IP Address 10 1 2 e Subnet Mask 255 o o BLUELINE CONFIGURATION Source selection Mode e Potentiometer Source from 1 to 99 4 Dual Invert Output 2 only MONO and SINGLE modes SAVE SETTINGS Generate Tone If you modify the name of the device the address in the web browser will change For example if you change the field Device name to receiver 2 you need to type receiver2 local BlueLine WORKIQ cori USER MANUAL 11 16 channel selector BLR 2 1e Connection por for BLC 1 pl BLR 2 um Ethernet RJ45 port AUDIO iP RECEIVER a LINE OUT e mos ON ACT Stereo audio output gt rae souace SELECTOR I Consi di 12 24V DC supply State indicators Take into account the following connection type LINE OUT IPL PIER da AMPLIFI DEVICE REMOTE port allows the connection of the zone controller BLC 1 This device is connected to BLR 2Lite directly through ethernet port From the external controller it is possible to select the desired channel and to adjust de volume level BLC 1 has an auxiliar audio input For further information go to page xXXXXXXXXXXXXXXX BLR 2Lite includes the same function of BLR 2 except the GPIO ports management Channel configuration and operating modes are the same as BLR 2 In case of more complex installations BLR 2 has an advanced configuration menu in order to ma
4. IP address of the destinatary The datagram is divided in two fields Head It has the information that the protocol needs to offer the service Data It has the message itself It must be delivered to destiny host The SubNet mask is a bits combination that is used to delimit the scope of a network Its function is to indicate to the devices which part of the IP address is the network number including t he subnet and which part corresponds to the host Basically with the SubNet mask gateway router will be able to know if needs to send data inside or outside the network For example if the router has 192 168 1 1 as IP address and 255 255 255 0 as SubNet mask all data sent to IP address which start in 192 168 1 will go to local network and the rest for outside network internet etc SubNet mask types Bits IPSubNet IP Broadcast Mask in decimal MIN 0 0 0 0 172 255 255 255 255 0 0 0 128 0 0 0 191 255 255 255 255 255 0 0 1110 224 0 0 0 239 255 255 255 not defined 1111 240 0 0 0 255 255 255 254 not defined 192 0 0 0 293 255 255 255 255 255 255 0 workigy Bue 49 USER MANUAL WORK Designed by EQUIPSON S A Avda El Saler 14 Pol Ind LAlter 46460 Silla Valencia Spain Tel 34 96 1216301 Fax 34 96 120 02 42 www workproaudio com support workproaudio com
5. be used to read and write using the same method The incremental method can not be shorted BlueLine workigy Bue 38 USER MANUAL When a property changes the device sends a number of notifications to the network for controllers who are listening can update their values These notifications are as follows O OSC Message multicast to IP 239 192 0 98 port 9001 This message path is formed as follows DEVICE_NAME ENTIRE_PATH OSC Message unicast to IP and ports that are registered as listeners To this must be registered with the appropriate command later is indicated The path of this message is the same as the property BlueLine workigy Bue i 39 USER MANUAL OVERVIEW OF THE BLUELINE DIGITAL PROTOCOL BlueLine digital devices communicate with each other by sending OSC packets through Ethernet There are two types of packets BlueLine packets only affect the parameters related to the BlueLine Digital system Common packets to all devices WORK modify the parameters related to the basic configuration IP name etc BluLine packets can be Unicast or Multicast it is the responsibility of the sender of the packets choose one or the other depending on the needs Common packets are always Unicast The BlueLine Digital system allows grouping devices into zones A zone is a set of devices that have the same logical behavior For example security zone room zone Zones allow us to ship orders to multiple de
6. format of the OSC messages is the next OSC Address Pattern OSC Type Tag String OSC Arguments OSC Address Pattern It is a string followed by the character O OSC Type Tag String It is a string beginning with the character followed by a sequence of characters that correspond to the type of OSC arguments that follow Types of OSC Type Tag Strings O i when the argument type is int32 workigy Blueline 35 USER MANUAL Selection channel indicator Audio level indicator SOURCE VOLUME AA BlueLine Auxiliar audio input Audio level adjustment Channel selector UO a w 00000 E BlueLine workigy Bluelit 36 USER MANUAL O f when the argument type is float32 O s when the argument type is OSC string O b when the argument type is OSC blob array of bytes The first four bytes are used to indicate the size of the data that follow O T True No argument associated to this Tap String O F False No argument associated to this Tap String OSC Arguments Are represented by a binary contiguous sequence of each argument NOTE All data are aligned to 4 bytes therefore the data do not occupy a multiple of four must add enough bytes with value 0x00 up to a multiple size of four NOTE 2 All strings end in 0x00 null OSC Address Pattern y OSC Type Tag String are strings therefor will always have to end in 0x00 y aligned to four bytes This byte to O also account for
7. is not waterproof and can malfunction if is exposed to high levels of moisture The internal oxidation can cause damage Do not hit it This product may malfunction it it is subjected to strong shock and vibration Keep away from strong magnetic fields Do not use or place the unit near equipments that generate strong fields of electromagnetic radiation or magnetic fields Heavy loads of these fields as radio transmitters can interfere with the display or affect the internal circuitry of the product Cleaning Due to the residues of smoke or dust to clean the outside of the unit is necessary Use a conventional glass cleaner an a soft cloth COPYRIGHT None part of this user manual may be reproduced transmitted transcribed stored in any system or translated into any language in any form or medium without permission workigy Blueline 3 USER MANUAL General View In this chapter you will find information about BlueLine features control operation and configuration WORK wees BLPSU msa rs 3 vi i a gt pa a lt 19 o o on 2 SLPSU Bis a BlueLine functions and configurations can be different depending on the BlueLine model Accessories The following accessories are included in the BlueLine Digital 1x Main supply cable Use this main power cable included in order to feed the BlueLine Digital 7x Individual covers Use these pieces to cover the empty slots 22x Screws Use these screws to fix
8. the individial covers in the empty slots worki Bustine 4 USER MANUAL Introduction In this chapter you will find information aboutBlueLine features and functions BlueLine Digital is a distributed audio system based on streaming over Ethernet It is possible to send several channels control via Ethernet and with a very low latency It can be a simple transmission point to point or a complete multichannel system with control and management of alarm The audio distribution is based in the transmission over IP network It is an economic and efficient concept easy to install and design Thanks to its Plug amp play system the intallers does not need any type of technical knowledge about network The central system is IP therefore it is possible to monitorize the netweok in order to check if any device in the systen does not work properly It anything happens an alarm message will be sent automatically to the users in order to check the system BlueLine digital is also compatible with other public address system lt can be used to transport several channel through the network It is possible to connect several power amplifiers designed t o 100V line installations It is an opportunity to control low and high installations with an unique audio system Thanks to the modular design of the system the installer can adapt BlueLine according to the requirements of each installation It is very interestying due to is allows to take advantage
9. to 70 km depending on the cable type In general the networks should always have more capacity that necessary In order to prepare a network is a good idea to design a network that use about the 30 of the full capacity The majority of devices connected to the network like a laptop or webcam are equipped with an Ethernet 100BASE TX 10BASE T interface common named as 10 100 interface this interface admits as much 10Mbit s as Fast Ethernet The cable type of twisted pair compatible with Fast Ethernet is Cat5 In order to connect several devices to a LAN is necessary a switch With this devices is possible to use a conventional network cable instead of a crossover cable The main function of a switch es to send the data from a device to another device in the same network It is an efficient method due to the data can be enrouted froma device to another device without affect to the rest of device in the same network worki Blueline 45 USER MANUAL Properties of BlueLine devices OSC Address OSC Type OSC P Pattern Tag String Description bl 1 source Indicates that the audio source is playing PRY Al source The device is in standalone mode standalone Indicates the area of the device MASTER ONLY Zone Name sets the name of zone 2 indicates the name of the zone to which you want to rename iT iF Set the volume to the indicated channel in 2 channel can be if Volume level O 1forLyR master 1forL 2forR
10. web server you need to type this name bls_2m local If you modify the name of the device the address in the web browser will change For example if you change the field Device name to emisor 1 you need to type emisor1 local Take into account that if the new name has not numbers or words you must replace them by this character _ Is recommended to set the devices separately before to connect them on the contrary in installation with grat complexity could be difficult to log in via web server Remember in the installation only can be connected one BLS 2 M In the BLUELINE CONFIGURATION section you can set the streaming channel assignation mode Potentiometer The channel selection is made trough the rotary source selector in the front side In this mode only you can select one channel between the 16 first of them Source from 1 to 99 Enter the number of channel from you want to streaming It is possible to select the channel between 1 to 99 In Format it is possible to select the codification mode ADPCM e Format Y PCM MP3 Once made the adjustments you need to store them Press Save settings button workigy Blueline 13 USER MANUAL WORK Bue id BLS 2 o BLS 2 DC SV E E 3 work FRONT REAR BLS 2 is a 1 stereo channel audio sender This unit is placed in the BLM and it occupies one single slot and it is supplied internally trough the 5V DC connectors The LAN connection is made thro
11. wn 1 2 3 A G G BLR 2 LNE LINE OUT o E ON ACT Stereo audio output set Sen State indicators BLR 2 incorporates 4 GPI ports and 4 GPO ports which state is reflected in the GPIO ports of the BLS 2M If you close the GPI 2 in the BLR 2 the unit will send the state al GPO 2 in all BLS 2M and vice versa Take into account the following connection type LINE OUT TO 0 AMPLIFIER f DEVICE REMOTE port allows the connection of the zone controller BLC 1 This device is connected to BLR 2 directly through ethernet port From the external controller it is possible to select the desired channel and to adjust de volume level BLC 1 has an auxiliar audio input worxi Blueline 24 USER MANUAL In case of more complex installations BLR 2 has an advanced configuration menu in order to make the necessary adjustments You can log in to this menu from you web browser The steps are as follows 1 Connect BLR 2 to a 12 24V DC main sypply 2 Connect the device to the LAN 3 Connect a PC or laptop to the same LAN 4 Start the web browser in your PC laptop and enter in the address bar bir_2 local 5 Your web browser will show WORK BLR2 CURRENT STATUS Automatic IP Address DHCP ZaroConfi Automabe Subnet Mask DHCP ZeroConh Enable Automatic IP Manual IP Address a Manual Subnet Mask o MAC Address Firmware Veesion NETWORK SETTINGS Device Name IP Address Subne
12. ACT It indicates that the unit is receiving sending data workigy Blueline 20 USER MANUAL BLS 2 AUDIO STREAMING CURRENT STATUS Automatic IP Address DHCP ZeroConf Automate Subnet Mask DHCP ZeroConf e Enable Automatic IP Manual IP Address e Manual Subnet Mask MAC Address e Firmware Version NETWORK SETTINGS Device Name IP Address Subnet Mask BLUELINE CONFIGURATION Source selection e Format 192 168 2 37 255 255 0 0 Y 10 12 24 255 0 0 0 00 25 80 00 02 18 v 1 301 BLS 2 10 1 2 24 255 o o 0 e Potentometer Source from 1 to 98 1 PCM SAVE SETTINGS In the NETWORK SETTINGS section it is possible to assig a static IP to the device and to set the subnet mask By default all BLMP 1 has the same device name bl_mp1 if you want to log in to the device through web server you need to type this name bl_mp1 local If you modify the name of the device the address in the web browser will change For example if you change the field Device name to Player1 you need to type Player1 local Take into account that you can connect any number of BLMP 1 in the network but not more than the maximum number of channels WORK BlueLine DigitatJL 21 USER MANUAL Next Mute Play Paus BLMP 1 Repeat p E d o e Source selector Channel A LED of state Prev E 5V DC supply USB port 4 ven 9 SD Card slot 3 Ethernet port C
13. BlueLine system It can accomodate up to 11 single modular units The basic configuration of BLM is compossed by a main supply unit BL PSU and a sender BLS 2M Once installed these elements it is possible to install up to 7 extra single units Ascoli e e o It 19 rack format with 3 HU allows to make all the connection internally trough the built in switch Each module is feed with 5V supplied for the BL PSU In the front side of the BLM are placed the LEDs state with the following functions ON It indicates that the unit is powered on LINK li indicates that the BLM is connected to the LAN ACT It indicates that the unit is receiving sending data workigy Blueline 7 USER MANUAL BL PSU O O O WORK BLPSU POWER AUX SUPPLY APESTA DO NOT OPEN WAL G SHOCK HAZAL 10 MOT OTE 18 36 Vdc MAINS SUPPLY LAN O O 220 230 Vac O O O BL PSU is the central main supply unit in the BluLine system this unit is placed inside BLM and it occupies 3 units The connection to main power 220 230 V AC is made through a cable IEC type included The IEC base socket has 1A fuse The LAN connection is made through a RJ 45 base socket and it has 2 LEDs of state It indicates that the unit is powered on ACT It indicates that the unit is receiving sending data LINK It indicates that the BL PSU is connected to the LAN In thecase of the main electric supply fall down BL PSU has an auxiliar 18 36
14. R MANUAL BLC 1 work BLC 1 SOURCE VOLUME 900000000 y hn uy NN 000090 BlueLine BLC 1 is an individual zone control with an auxiliar audio input This unit can be placed up to 20 meter of the receivers and the connections between both devices must be carried CAT5 cable between REMOTE ports of both devices Take into account that the REMOTE port in BLS 2Lite has no fuction and therefore the BLC 1 can not be connected here BLC 1 is mounted in a surface box onece the device is installed it as a dimmensions of 85 x 85 x 40 mm The auxiliar input connection is made through stereo minijack connector 3 5 mm worki Blueline 34 USER MANUAL OSC PROTOCOL BlueLine Digital uses the OSC protocol for communication between devices OSC Open Sound Control is a communication protocol that enables the communication of computers musical instruments and other multimedia devices smart phone tablet designed to share musical information in real time over a network Scalable and dynamic Scheme type URL of symbolic names High resolution numerical data Pattern matching language to specify multiple receivers of a single message High resolution time marks Packed messages for those events that must occur simultaneously Interrogation system to dinamically find the capabilities of a OSC server and get documentation It can be transported by various protocols but UDP is normally used The
15. V DC input workigy Blueline 8 USER MANUAL BLS 2M O BLS 2M AUDIO IP STREAMER GPO GPI 1 BLS 2M AUDIO IP STREAMER 2 3 4 G G DC 5V BID SI ME SOURCE Ma SELECTOR T G N2 workl WORK O FRONT REAR BLS 2M is a 1 stereo channel audio sender This unit is placed in the BLM and it occupies one single slot and it is feed insternally trough the 5V DC connectors The LAN connection is made through the connectin between the unit with the inner switch using a RJ 45 cable Thanks to the frontal audio source selector it is possible to select quickly from 1 to 16 emmision channel In the front side you can find a LED indicating the state of the device ACT It indicates that the unit is receiving sending data The connection of audio inputs and alarm is made through terminals NOTE One BlueLine installation MUST only have one BLS 2M worxi Blueline 9 USER MANUAL GPI port GPO port E 2M Alarm connection i BLS 2M TENET Activity indicator Nn peer li 1 to 16 channel selection o Pi mi LAN Balanced audio input IN A TT iL 1E RJ 45 Ethernet port Balanced audio input IN B won w work BLS 2M incorporates 4 GPI ports and 4 GPO ports which state is reflected in the GPIO ports of the BLR devices If you clese the GPI 2 in the BLS 2M the unit will send the state al GPO 2 in all BLR and vice versa Take into account that when you close
16. WORK Y 2 o Dre e a Ei am E D i E BlueLine Digita L JUL User manual English version Contents gt Precautions tt ail heh hiatal best lit ia Lidia it 3 O Aldo ati 4 ACCOSSOTIES lei cie aa 4 Ai ail alia 5 Componentes del Sistema iii 6 iE O 7 BP Uca pala asii 8 BES Md a a ae 9 O 14 BES ZULU A AAN E E 17 EMP aaa 20 O A O 23 A O 28 BIRRA I ei iaia rela 31 BES Manara 34 USO cad 6 05 Dera a EE A ee ee A 36 OSC for working with propertieS 38 Overview of the BlueLine protocol 40 packet types in BluLine protocol i 42 UDP 8 IP protocols configuration 43 BlieLine protocol packets cceeeceeesceeeeeeeeeeeeeeeeeeeeeeesneeeeeees 44 Basic notions about LAN NGtWwOrkS cocoa 46 Basic notions about IP Proton a 48 PRECAUTIONS Tu reduce the risk of electric shock or fire do not expose this appliance to rain or moisture Do not spill water or another liquid over the unit Turn off the unit immediately if you detect a malfunction If you detect smoke or unusual odor from the equipment stop using and unplug it Do not open the unit There are not items for the user control inside Do not dismantle or modify the unit void the warranty Never try to repair it Repairs by unqualified persons may cause damage or malfunction Contact with authorized service Keep dry the unit This product
17. computing the size of the string For example hola 23 has a size of 9 instead of 8 For a better understanding of this document will obviate all this in the explanation of each command firmware mission is to implement correctly BlueLine worxi Buel i 37 USER MANUAL OSC FOR WORKING WITH PROPERTIES OSC protocol defines the transmission os messages or commands But also can be used for reading and modification of device properties After all work with properties imply the transmission of commands Read command or Write command of the propertry accessed When the properties are used we have adopted the next convention in the BL protocol O Writing bl ZONE PROPERTY set with only one parameter of type that the property is with the value that we want to assign to property O Incremental writing bl ZONE PROPERTY inc with only one parameter of type the property is with the increment value we want to assign O Reading bl ZONE PROPERTY get with no parameter The device will respond with a shortened set message continue reading Due to the variety of messages can be shortened to O Writing bl ZONE PROPERTY with only one parameter This is the message short writing exactly as above but without set O Reading bl ZONE PROPERTY with no parameter Exactly as above but without get The only difference between the messages of writing and reading is the number of parameters can
18. e activated through Web Server Take into account the next connection types according to its audio source External Audio Stereo input with unbalanced signal Stereo input with balanced signall By default the streamers BLS 2 BLS 2M and BLS 2 Lite are configured to send the audio sources in PCM format although they can be adjust according to the necessities PCM To broadcast up to 16 audio stereo channels with a consumption lower than 10 Mbit ADPCM To broadcast up to 32 audio stereo channels with a consumption lower than 10 Mbit To broadcast up to 64 audio stereo channels with a consumption lower than 10 Mbit Each codification type has its advantages and disadvantages the codification will be chosen according to the number of audio sources PCM It has all information extracted from the Analog Digitsal conversion without any omission therefore it has the best quality It is a format withou compression and the bandwidth consumption is elevate 1 5 Mbps wornigy Plueline 11 USER MANUAL ADPCM It stores the difference in value between 2 adjacent samples allowing the data reduction due to the high frequencies are reproduced correctly bua any low frequency will lost quality It bandwidth consumption is about 500 Kbps MP3 This codification is a standard used in audio streaming and compression with a moderate loss of fidelity thanks to the possibility to adjust the compression quality and therefore the size
19. e packet is executed by all devices in the system The send address of the packet is the multicast address as send addres provided data Field Zone 0 NOTA Not be confused with broadcast IP The data is transmitted by BlueLine Broadcast to wit in Multicast IP but the field Zone is 0 worxi Blueline 42 USER MANUAL UDP AND IP PROTOCOLS CONFIGURATION All BlueLine messages are transmitted over UDP IP In the BL protocol the following IP Multicast addresses are used O 239 192 0 100 For the transmission of control messages O 239 192 0 101 SOURCE For the transmission of audio packets Each SOURCE uses a different IP address Starts with SOURCE 0 O Device IP You can also use the IP Unicast assigned to the device to transmit control messages The UDP protocol is used in the following ports O 3125 for the reception of audio packets O 3126 for the reception of control packets BlueLine worRKi coin E 44 USER MANUAL BLUELINE DIGITAL PROTOCOL PACKETS Common OSC messages OSC Address OSC Type OSC ee Records the source IP address and port with the device or the reception of changes in properties osc add UDP Foreign Port If port is O is taken as port the local port specified in he UDP packet osc del UDP La Foreign Port Unregisters IP address and port BlueLine OSC messages All messages have as the first parameter in the name the zone wich the message is intended
20. e the same as BLS 2 In order to log in to advanced configuration menu trought your web browser follow the next steps 1 Connect the BLS 2Lite to a 12 24V DC main sypply 2 Connect the device to the LAN 3 Connect a PC or laptop to the same LAN 4 Start the web browser in your PC laptop and enter in the address bar bls_2 lite local workig Bustine 17 USER MANURE BLS 2Lite PEA elite REMOTE SOURCE SELECTO ao o e BLS 2LITE AUDIO IP STREAMER LAN potas e FRONT mo 1G2 BLS 2 Lite is a stereo unbalanced audio streamer of 1 channel It is an external module and can be placed anywhere It must be supplied through POE or with an external 12 24 V DC power supply Thanks to the source selector in the rear side you can select easily the streaming channel between 1 to 16 In the front side you can found LEDs which indicate the state of the device It indicates that the unit is powered on LINK li indicates that the BLM is connected to the LAN It indicates that the unit is receiving sending data work Blueline 18 USER MANUAL 5 Su e navegador web mostrar los siguiente BLS 2 Lite CURRENT STATUS Automatic IP Address DHCP ZaroConf Automatic Subnet Mask DHCP ZeroConf e Enable Automatic IP e Manual IP Address Manual Subnet Mask e MAC Address Firmware Version NETWORK SETTINGS Device Name Address e Subnet Mask BLUELINE CONFIGURATION So
21. hannel and to adjust de volume level BLC 1 has an auxiliar audio input BLR 2A includes the same function of BLR 2Lite but also it includes 2 amplified outputs Channel configuration and operating modes are the same as BLR 2Lite Depending on how feeds the BLR 2A you can obtain different power output worxi Blueline 32 USER MANUAL Max power output 2 x 5W 12 24V Max power output 2 x 15W In case of more complex installations BLR 2A has an advanced configuration menu in order to make the necessary adjustments You can log in to this menu from you web browser The steps are as follows 1 Connect BLR 2A to a 12 24V DC main sypply 2 Connect the device to the LAN 3 Connect a PC or laptop to the same LAN 4 Start the web browser in your PC laptop and enter in the address bar bir_2 a local 5 Your web browser will show s WORK W j BLR 2A AUDIO STREAMING CURRENT STATUS Automatic P Address DHCP ZeroConf 192 168 258 Automatic Subnet Mask DHCP ZeroConf 255 255 0 0 Enable Automatic IP x e Manual IP Address 10 1 2300 Manual Subnet Mask 255 0 0 0 e MAC Address 00 25 80 00 02 1E e Firmware Version v 130 1 NETWORK SETTINGS Device Name BLR 2 Lite IP Address 1 1 2 e Subnet Mask 255 D o BLUELINE CONFIGURATION Source selection e Potentiomater Source from t to 99 1 Mode Dual inver Output 2 only MONO and SINGLE modes SAVE SETTINGS Generate Tone BlueLine WORK S cout 33 USE
22. ke the necessary adjustments You can log in to this menu from you web browser The steps are as follows work Blueline 29 USER MANUAL BLR 2A BLR 2A AUDIO IP AMPLIFIER REMOTE ne AMP OUTS SELECTOR DC 12V 24V 2 1 WO gp am BLR 2A AUDIO IP AMPLIFIER LAN LINE OUT e A Front ON ACT 1G2 BLR 2A is a 1 channel stereo unbalanced audio receiver and 2 amplified outputs It is an external module and can be placed anywhere It must be supplied through POE or with an external 12 24V DC power supply Thanks to the source selector in the rear side you can select easily the streaming channel between 1 to 16 In the front side you can found LEDs which indicate the state of the device It indicates that the unit is powered on LINK It indicates that the BLR 2A is connected to the LAN It indicates that the unit is receiving sending data WORK Bue id 31 USER MANUAL 1 16 channel selector 12 24V DC supply AMP OUTS Amplified output Left g OC 134340 2 ka E Amplified output Right BLR 2A di a Ethernet RJ45 port UNE OUT ry ee 162 E x Connection por for BLC 1 Stereo audio output State indicators Take into account the following connection type LINE OUT TO AN HOT AMPLIFIER ge DEVICE REMOTE port allows the connection of the zone controller BLC 1 This device is connected to BLR 2A directly through ethernet port From the external controller it is possible to select the desired c
23. le mode 2 unbalanced outputs by default or 1 balanced output WORK Bue id 27 USER MANUAL BLR 2Lite BLR 2urre AUDIO IP REC REMOTE SOURCE SELECTOR DC 12V 24V a POSTERIOR BLR 2 urte AUDIO 1 ECEIVE LAN LINE OUT yens ion FRONTAL aanl se 162 BLR 2 Lite is a 1 channel stereo unbalanced audio receiver lt is an external module and can be placed anywhere It must be supplied through POE or with an external 12 24 V DC power supply Thanks to the source selector in the rear side you can select easily the streaming channel between 1 to 16 In the front side you can found LEDs which indicate the state of the device It indicates that the unit is powered on LINK It indicates that the BLR 2 Lite is connected to the LAN It indicates that the unit is receiving sending data One BlueLine installation can be connected whatever number of BLR 2Lite work Blueline 28 USER MANUAL 1 Connect BLR 2Lite to a 12 24V DC main sypply 2 Connect the device to the LAN 3 Connect a PC or laptop to the same LAN 4 Start the web browser in your PC laptop and enter in the address bar bir_2_ lite local 5 Your web browser will show a WORK Ww j BLR 2 Lite AUDIO STREAMING CURRENT STATUS e Automatic IP Address DHCP ZeroConf 192 168 2 58 e Automatic Subnet Mask DHCP ZeroConf 255 255 0 0 Enable Automatic IP Y e Manual IP Address 10 1 2 30 Manual Subnet Mask 255 0 0 0 e MAC Address 00 25 80 00 02 1E
24. of the advance system without a price increment in the installation Features Management of audio sources and output zones Multiple codification types GPIO control Real time monitorization of the system Web Server configuration OSC control POE work Blueline 5 USER MANUAL Elements of the sytem En este capitulo encontrar informaci n acerca de los diferentes elementos que componen el sistema BlueLine Digital El sistema BlueLine Digital cuenta con cuatro clases de dispositivos Central System Senders Receivers Controllers BLM BL PSU BLS 2M BLS 2 BLS 2 LITE BLMP 1 BLR 2A BLR 2 BLR 2 LITE BLC 1 WNC Modular central unit of the BlueLine system Main supply unit of the central BlueLine system 1 stereo channel sender with GPIO for BLM 1 stereo channel sender for BLM 1 unbalanced stereo channel sender external MP3 player with FM radio tuner 1 stereo channel receiver with amplifier 1 stereo channel receiver with GPIO 1 stereo channel receiver Zone control for the receivers Zone control Note In some points of this manual we speak about Zone of devices take into account that these are virtual zones when you can manage the device according to their type Senders or Receivers This point has not make reference to Audio zones BlueLine WORKIQ 5 51 I USER MANUAL BLM BlueLine AM The BLM is the central modular unit for
25. of the final transmission that can occuped up to 12 times less than an original transmission without compression It bandwidth consumption is about 220 Kbps In case of more complex installations BLS 2M has an advanced configuration menu in order to make the necessary adjustments You can log in to this menu from you web browser The steps are as follows 1 Connect BLS 2M to a 5V DC main sypply 2 Connect the device to the LAN 3 Connect a PC or laptop to the same LAN 4 Start the web browser in your PC laptop and enter in the address bar bls_2m local 5 Your web browser will show WORK Ww j BLS 2M AUDIO STREAMING CURRENT STATUS e Enable e Manua idres e Manual Subnet Mask 255 0 0 0 e MAC Addres 00 25 80 00 02 15 e Firmware Version v1 30 1 NETWORK SETTINGS e Device Name ELSIM e iP Address 10 1 2 21 Subnet Mask 255 o o o BLUELINE CONFIGURA TION e Source selection Polentiometar Source trom 1 to 99 La vi Pem le No actior Source change SAVE SETTINGS worxi Bustine 12 USER MANUAL The CURRENT STATUS section shows the information of the device its IP MAC address and firmware version If you want to assig a static IP to your BLS 2M you must to unmark the Enable Automatic IP option In the NETWORK SETTINGS section it is possible to assig a static IP to the device and to set the subnet mask By default all BLS 2 M has the same device name bls_2m if you want to log in to t he device through
26. one GPI in the BLS 2 M its state will appears in all BLR with GPIO although they are in different channels When you act over the GPI 1 in the BLS 2M all the device in the zone 2 by default we considerer them paging zone or receiver zone to listen in the channel O with maximum volume This will act the paging function which made the following functions 1 The unit sends a push message which includes the state of the device 2 lt sends the command source 0 3 It sends the command Mode Single 4 lt sends the Master Channel1 and channel 2 volume to 0 dB When the GPI 1 is disactivated it sends a pop message which loads the configuration previous to push message By default the BlueLine system is configured in two zones Zone 1 For senders Zone 2 For receivers push Command usedf to read the state of a device and to store its configuration pop Command used to load the stored configuration through a push command worxi Blueline 10 USER MANUAL The alarm connector allows to connect a push button or switch in the BLS 2M therefore when the contact is closed the alarm condition is activated in the BlueLine system In this condition all receivers will pass to channel 0 and wil adjust the audio level to maximum When the contact will be opened in the push button or switch the alarm condition will be disabled returning all receiver to their initial state By default the alarm is disabled it can b
27. onnected to BLM worxiD work Display Channel configuration and codification type are the same as BLS 2 and BLS 2M In fact BLMP 1 is a player integrated inside a BLS 2 herefore the configuration are the same In order to log in to advanced configuration menu trought your web browser follow the next steps 1 Connect the BLMP 1 to a 5V DC main sypply 2 Connect the device to the LAN 3 Connect a PC or laptop to the same LAN 4 Start the web browser in your PC laptop and enter in the address bar bl_mp1 local workig Blueline 22 USER MANOR BLR 2 BLR 2 AUDIO IP RECEIVER GPO GPI REMOTE SOURCE SELECTOR BLR 2 AUDIO IP RECEIVER LAN LINE OUT Pa mi Pi L FRONTAL ON ACT 1G2 POSTERIOR BLR 2 is a1 channel stereo unbalanced audio receiver It is an external module and can be placed anywhere It must be supplied through POE or with an external 12 24 V DC power supply Thanks to the source selector in the rear side you can select easily the streaming channel between 1 to 16 In the front side you can found LEDs which indicate the state of the device It indicates that the unit is powered on LINK It indicates that the BLR 2 is connected to the LAN It indicates that the unit is receiving sending data work Blueline 23 USER MANUAL 1 16 channel selector GPI port Ethernet RJ45 port ee 12 24V DC supply BLR2 AUDIO IP ROCHE WER Connection por for BLC 1 REMOTE goua an
28. press as 32 bit number Therefore we can identify easily the octets which belong to network and host id NetID is made with the bits to 1 of the Subnet mask HostD is made with the bits to 0 of the Subnet mask Adresses examples 11 10 200 1 A class NetlD 11 amp HostID 10 200 11 from 0 to 127 Subnet mask 255 0 0 0 150 214 53 127 B class NetID 150 214 8 HostID 53 127 from 128 to 191 Subnet mask 255 255 0 0 192 168 13 102 C class NetID 192 168 13 amp HostID 102 from 192 to 223 Subnet mask 255 255 255 0 There are special adresses that must not be assigned to a host due to they have an own purpose Network addresses The network have their own address NetID with the network ID and HostlD to 0 Example 150 214 0 0 Broadcast addresses They define the broadcast address to IP level It consists in the NetID with the network ID where the broasdcast will be made and in the HostlD all values goint to 1 Example 150 214 255 255 Loopback address They are A class addresses 127 X X gt X that has been reserved to support broadcast between applications of the same host and to check their operation without interfer with then B default the loppback address used is 127 0 0 1 Multicast address They are D class address and it is not allows to use them for unicast addresses USER MANUAL WORK RISE 47 The supply through Ethernet PoE or Power Over E
29. t Mask BLUELINE CONFIGURATION Sourve selecton Mode AUDIO STREAMING 192 1682 58 255 25500 M 10 12 30 255000 00 28 80 00 02 1E v1 30 1 BLK 755 e 0 o Polansoeeter Sauros from 1 to 99 1 Dual inven Output 2 only MONO and SINGLE modes SAVE SETTINGS Generate Tone The CURRENT STATUS section shows the information of the device its IP MAC address and firmware version If you want to assig a static IP to your BLR 2 you must to unmark the Enable Automatic IP option BlueLine worxi Pluelir 25 USER MANUAL In the NETWORK SETTINGS section it is possible to assig a static IP to the device and to set the subnet mask By default all BLR 2 has the same device name blr_2 if you want to log in to t he device through web server you need to type this name blr_2 local If you modify the name of the device the address in the web browser will change For example if you change the field Device name to receiver 1 you need to type receiver1 local Take into account that if the new name has not numbers or words you must replace them by this character _ ls recommended to set the devices separately before to connect them on the contrary in installation with grat complexity could be difficult to log in via web server Remember in the installation can be connected whatever number of BLR 2 In the BLUELINE CONFIGURATION section you can set the streaming channel assignation mode Potentiome
30. ter The channel selection is made trough the rotary source selector in the front side In this mode only you can select one channel between the 16 first of them Source from 1 to 99 Enter the number of channel from you want to streaming It is possible to select the channel between 1 to 99 Inside Mode it is possible to select 3 type of output configurations Dual Mode stereo There is to unbalanced outputs Each input has its own output therefore one stero input will have a stereo output OUT 1 IN 1 OUT 2 IN 2 Balanced inputs unbalanced outputs It is the perfect mode work Blueline 26 USER MANUAL Single mode In this mode by default both outputs offer the same signal therefore in OUT 1 and OUT 2 there is the same signal IN 1 or IN 2 Also it is possible that instead of two equal signals by default can be configured one balanced output through webserver Once selected Single mode The output mode change through webserver 12 Unbalanced OUT1 IN1 or IN2 OUT2 IN1 or IN2 2 Balanced OUT1 N1 or IN2 OUT2 IN1 or IN2 Take into account that in this mode the sources operate channel to channel In Dual and Mono modes the sources operate sender to sender Mono mode Is like Single mode but in this case the input signal are added 12 Unbalanced OUT1 INTE IN OUT2 1 IN2 2 Balanced q _MN1 IN2_ YK 2 J The output operation is the same as sing
31. that you can connect any number of BLS 2 in the network but not more than the maximum number of channels Take into account the next connection types according to its audio source External Audio Stereo input with unbalanced signal Stereo input with balanced signall work Blueline 15 USER MANUAL BLS 2 BLS 2 oe a 5V power supply Activity indicator E ae eg mea Tua 1 to 16 channel selection ma LAN Balanced audio input IN A erT fg RJ 45 Ethernet port work 7 Balanced audio input IN B work BLS 2 has the same functions as BLS 2M except GPIO ports and alarm management The channel configuration and codification type are the same In order to log in to advanced configuration menu trought your web browser follow the next steps 1 Connect the BLS 2 toa 5V DC main sypply 2 Connect the device to the LAN 3 Connect a PC or laptop to the same LAN 4 Start the web browser in your PC laptop and enter in the address bar bls_2 local won Blueline 16 USER MANUAL 1 16 channel selection BLS 2LITE Tel ra se uni 12 24V power supply Dezi NO FUNCTION eee LAN LINE IN e e a Ethernet RJ 45 port mm s Stereo unbalance ae OM ACT audio input 144 State indicator Take into account the following connection type 162 LINE IN HO In contradistinction to BLS 2 BLS2Lite is a 1 channel unbalanced stereo streamer The channel configuration and codification type ar
32. thernet allows to supplied the devices connected to the Ethernet network using the same cable4 that the used for data broadcast The main advantage of PoE is the cost seving It is no necessary to installa a separate electric line It is very useful in zones with a difficult access due to that it is not necessary to installa an additional cable PoE facilities the possibility the change the nodes postiion or to add additional points Also the audio system security increases An audio system with PoE can supplies a server room that normally is protected with a UPS Uninterrupted power system therefore the audio system can operate even during power outage Due to its advantages it is advisable to use PoE in the majority of devices the powe of the switch or midspan with PoE should be enough to the connected devices and they must to admit the classification power The RJ 45 connectors are used with the UTP wires It has 8 ways with 8 pins when the cable is crimped el connector will link with the cable making possible the data broadcast Standard Patch Cable 45678 12345678 Termination 1 amp 2 Same EIA TIA 568 A Pinout for TS68B BlueLine workigy BUS 48 USER MANUAL IP protocol uses IP addresses in order to identify the source and the destiny ina datagram But the datagram travel inside a frame and it uses hardware addresses By this reason we need to use ARP protocol to determinate the hardware address corresponding to
33. ugh the connectin between the unit with the inner switch using a RJ 45 cable Thanks to the frontal audio source selector it is possible to select quickly from 1 to 16 emmision channel In the front side you can find a LED indicating the state of the device ACT It indicates that the unit is receiving sending data Una instalaci n de BlueLine puede contener los BLS 2 que desee siempre y cuando no exceda el l mite m ximo de canales indicados en la tabla de la p gina 11 14 USER MANUAL WORK wW BLS 2 AUDIO STREAMING CURRENT STATUS Automatic IP Address DHCP ZeraCant 192 168 2 37 e Automatic Submet Mask DHCP ZeroConf 255 255 0 0 Enabie Automate IP ES e Manual IP Address 10 12 24 e Maral Subnet Masi 255000 e MAC Address 00 25 80 00 02 18 e Firmware Version v 130 1 NETWORK SETTINGS e Device Name BLS e Addrass to t 2 24 Subnet Mase 255 0 o 0 BLUELINE CONFIGURATION e Source selecton Potentometer Source bom 1 to 99 e Format PCM SAVE SETTINGS In the NETWORK SETTINGS section it is possible to assig a static IP to the device and to set the subnet mask By default all BLS 2 has the same device name bls_2 if you want to log in to t he device through web server you need to type this name bls_2 local If you modify the name of the device the address in the web browser will change For example if you change the field Device name to emisor 8 you need to type emisor8 local Take into account
34. urce selection e Format AUDIO STREAMING 192 168 2 37 255 255 0 0 x 10 12 24 255 0 0 0 00 25 80 00 02 18 v 1 30 1 BLa 2 10 10 2 24 235 0 0 0 Potentiometer Source from 1 to 99 1 PCM SAVE SETTINGS In the NETWORK SETTINGS section it is possible to assig a static IP to the device and to set the subnet mask By default all BLS 2Lite has the same device name bls_2 lite if you want to log in to the device through web server you need to type this name bls_2 _lite local If you modify the name of the device the address in the web browser will change For example if you change the field Device name to PC1 you need to type PC1 local Take into account that you can connect any number of BLS 2 in the network but not more than the maximum number of channels BlueLine DigitatJL WORK 19 USER MANUAL BLMP 1 BLMP 1 3 DC 5V ere i da jo C mf O A 3 woani worxi FRONTAL POSTERIOR BLMP 1 is a streamer and MP3 player with FM radio integrated This unit is placed in the BLM and supplied internally through 5V dc connectors It occupies 2 slots into the BLM The adio files can be played from an USB stick or SD card both of them must be formatted in FAT32 with a maximum storage of 32 GB Thanks to source selector in the front side it is possible to select the streaming channels between 1 and 16 In the front side you can fin a LED inditating the state of the device
35. vices at once By default all devices are assigned to a particular zone ZONE 0 broadcast Zone All devices listen in this zone as well in their assigned area The function of this zone can not be modified ZONE 1 Zone of senders O ZONE 2 Zone of recivers also the area that is used for pagging messages workigy Blueline 40 USER MANUAL The addresses of BlueLine packets always have the following structure b ZONE MESSAGE In the packet address the zone to which the message is intended is encoded For a better understanding of the areas of the system in to the master device can assign a name to each of existing areas worki Blueline 41 USER MANUAL PACKET TYPES IN BLUELINE PROTOCOL There are several types of OSC packets depending the recipients that will be sending these packets Unicast The packet is executed by a single device The packet is sent to the IP address of the device For simplicity the zone field must be 0 but may have the value of the target zone Multicast The packet is executed by a device set in particular those belonging to a zone The send address of the packet is the multicast address as send address provided data The field zone is set in the zone to control NOTE As the packet is multicast all devices receive the information Those devices whose area does not correspond to the area specified in the packet is discarded Broadcast Th