Home

User Manual ADAM-3600-A1F

image

Contents

1. nen nennen nennen 14 Figure 3 6 Ethernet Daisy Chain Wiring 2222 aaa anava anni 14 0 00 NOU E 15 System Configuration 17 EE 18 Configure the ADAM 3600 A1F with the Web Interface 18 4 2 1 System Requirements i 18 4 2 2 List of ADAM 3600 A1F Default Ethernet Ports 18 V ADAM 3600 A1F User Manual 4 3 4 4 Appendix A A 1 A 2 A 3 Appendix B B 1 B 2 4 2 3 Factory Default Settings A 19 4 2 4 Module Authorization Vs 19 4 2 5 Using a Browser to Configure the Module 20 Configure ADAM 3600 A1F with ADAM NET Utility 37 4 3 1 Operation Framework nen kn keen kk ernennen 37 Configuring ADAM 3600 A1F with ADAM NET Utility software 41 UO Modbus Mapping Table HERRE EEE EEE EEE 45 Modbus Function Code Introduction 46 ADAM 3600 A1F Default Modbus Mapping Table 46 Auto Allocated Modbus Address 48 REST for ADAM 3600 A 1F 51 OO OR III 52 REST Resources for ADAM 3600 A1F nennen 58 Bl Digtal AL vene 53 BA DA NN 58 ADAM 3600 A1F User Manual VI Chapter 1 Product Overview 1 1 Introduction ADAM 3600 A1F is an intelligent remote I O module which provides 16 digital inputs 8 relay outputs and 4 I O expansion slots to approach different scenarios Except var ious I O type offering ADAM 3600 A1F provid
2. ADAM 3600 A1F User Manual 34 Media Log Configuration File Viewer File Viewer Query Filter v Source USB Thumb Time Filter Enabled Disabled Amount of Latest Files Filter C Enabled Disabled File Format Filter Enabled Disabled File Viewer Tab Query Filter This filter is for setting the criteria to query the logged CSV file from USB Thumb or SD card Users can select the filter modes they want to use and click Query button to query the logged files Time Filter M Enabled Disabled Amount of Latest Files Filter i Enabled Disabled File Format Filter Enabled Disabled Timestamp of the Oldest 2015 05 19T15 09 04 Start Time 2015 05 19T 15 09 04 Timestamp of the Latest 2015 05 19T15 20 32 End Time 2015 05 19T 15 20 32 There are three filter modes for the file viewer of the media storage Time filter Amount of Latest Files Filter and File Format Filter If the user selects Time Filter they can see the time stamps of the oldest file and the latest file in the storage device Then users can set the time period by setting Start Time and End Time This period has to be between the oldest time stamp and the latest timestamp Then they can query the files in the storage device that the timestamps in this period Time Filter Enabled Disabled Amount of Latest Files Filter v Enabled Disabled File Format Filter Enabled Disabled Current Total Amout 4 Start Index 1
3. ADAM 3600 A1F is always at Slot 0 then Slot 1 4 correspond to 4 expansion module slots in sequence 21 ADAM 3600 A1F User Manual Configuration Page Configuration Configuration Network Network App Time amp Date SNTP Modbus Control General Firmware Account Information Users can click different tab to switch the item you are going to configure Module Information Model Name ADAM 3600 A1F Customized Name ADAM 3600 A1F UUID ADAM 3600 A1F 00DOC9FEFF39 Description Choose the Information tab then user can edit Module Information which contains Customized Name Universally Unique Identifier UUID and Description Location Information Latitude Longitude Altitude Location Users can edit the location information for the module While the edition of Module and Location Information had been completed click the button Submit to restore the new infor mation ADAM 3600 A1F User Manual 22 Network Configuration Information Network App Time amp Date SNTP Modbus Control Network Mac 00 D0 C9 FE FF 39 IP 10 0 0 1 Gateway 0 0 0 0 General Firmware Account Subnet 255 0 0 0 IP Mode Static O DHCP O Dip Switch IP There are three options for the selection of IP Mode They are Static Insert the user defined IP directly DHCP and DIP Switch IP respectively Users can select the way they want to configure the IP address of the module by the IP Mode selection They also can set the sub n
4. Devices iii 2 Flexible I O deployment aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaanaaauaanaaaauaanaaaaaaana 2 Mechanical Design and DIMENSIONS i 3 1 4 1 ADAM 3600 A1F ii 3 LEIDEN OT eege 4 Certification and Safety Standards nenn nenn nennen 5 Product Specifications General Specification anne nnn nenne anne nnnennne nenne name nennen 8 Beji MMO EE EEE EA FARE 9 2 2 1 Digital Input SpecificatioNS nen kn kk nn 9 222 Digital INDUL WINNG E 9 Figure 2 1 ADAM 3600 A1F Digital Input Wiring 9 FA UN 9 2 3 1 Relay Output Gpechtfcatons nenn nenne namen 9 2 3 2 Relay Output Wmg ss 10 Figure 2 2 Relay Output Wiring 10 PI ES SEE EEE 10 Hardware Installation 11 Interface Introduction ss 12 NOUIN ONO E 12 32 1 DIN R l MOUNUNG en 12 Figure 3 1 DIN Rail InstallatioN 2er 12 3 2 2 Wall Mounted Installaton nennen nennen 13 Figure 3 2 Wall Mounted Installation 13 3 2 3 Expansion Module Installation 13 Figure 3 3 Expansion Module Installation 13 Figure 3 4 Expansion I O Connector Installation 13 Wiring amp Connections iii 14 3 3 1 Power Supply WWumng sneen ens keen nen k kk r nennen 14 Figure 3 5 Power Supply Wiring 14 3 3 2 Ethernet Daisy Chain Wiring
5. End Index 4 If users select Amount of Latest Files Filter they can see the total number of files in the stor age device at the field Current Total Amount Users can set the index period by setting Start Index and End Index then they can query the files in the storage device that the indexes in this period Time Filter Enabled Disabled Amount of Latest Files Filter i Enabled Disabled File Format Filter M Enabled Disabled Data Format CSV If users selected File Format Filter then they can query the CSV files in the storage device 35 ADAM 3600 A1F User Manual Data Show 10 w entries File Timestamp 0 ADAM _log 0 FF39_0 csv 2015 05 19715 09 04 0 ADAM log 0 FF39 1 csv 2015 05 19715 18 12 Users can check the file list at the Data area The data logger function would generate a main folder ADAM log in the external storage device It would contain the first sub folders which named with the index 0 and the logged file would be stored in the sub folder The file name would be the last two bytes of the MAC address and the index started from 0 The indication of the CSV file format is shown below MAC address Folder Index File Index Timestamp for building up this file 94665687 946658871 46658872 046658872 946658572 946658872 946658872 FLEET 946658872 ak Vi fy bl M Vi f E V Vi Aw e LF n 4 e VM n d Log way Data Timestamp Data from 1 0 channel P Periodic E Eve
6. Log Chart Data Log Export For PC platforms the minimum requirement of web browsers as below al Internet Explorer version 11 E Google Chrome version 30 u Mozilla Firefox version 25 Mobile Browse Chrome Firefox Sei pr pp Y py y Y File Upload Y Y N Y N N _ Data Log Chat Y Y Y Y Y N _ Data Log Export Y Y N N N N 4 2 2 List of ADAM 3600 A1F Default Ethernet Ports Websener Top 80 Configurable Modbus Server TOP 82 Search Engine s SNTP Client UDP Randomly ADAM 3600 A1F User Manual 18 4 2 3 Factory Default Settings IP Mode Static IP Address Default IP 10 0 0 1 Subnet Mask 255 0 0 0 Default Gateway 0 0 0 0 Default Connection Timeout 720 second HTTP Port 80 4 2 4 Module Authorization Account Default Password Access Ability 00000000 All the privileges 00000000 All the privileges except access control configuration 00000000 View module status only not allow to do configuration 19 ADAM 3600 A1F User Manual 4 2 5 Using a Browser to Configure the Module H Configure URL http IP address config E Default URL http 10 0 0 1 config g Configuration Steps Login Web Page 10 0 0 1 ADAM 3600 Web Acco Parmer Information O Module Model Name ADAM 3600 A1F Customized Name ADAM 3600 A1F UUID ADAM 3600 A1F 00DOC9FEFF39 D Log Out 6 ADAM 3600 A1F User Manual 20 C
7. Name Clear Counter 7 FW Major Ver 00617 00624 40229 40230 FW Build Ver E EEE BE fe kk DI Value LL Je Digital Output EES dl DO Value mn S KEE Level Width 2 addr ch Read Read Read Read Read Read Read 1 addr ch Read Read Read Read Read Read 1 addr ch 01009 01016 41017 41032 III TI kon an RW DO Value pp ab RW High Level Width GC ADAM 3600 A1F User Manual 48 Pulse 41817 41832 2 addr ch 49 ADAM 3600 A1F User Manual ADAM 3600 A1F User Manual 50 Appendix B REST for ADAM 3600 A1F B 1 Introduction REpresentational State Transfer REST is a design style of software architecture for Web application behaves and services including image indication resource request and response and message delivery It can be developed compatible with popular protocols or standards like HTTP URI JSON HTML VVith the advantage of scalabil ity simplicity and performance it s already adopted m Web service by Amazon Yahoo The Web service of is developed based on HTML5 language if user need to integrate this into other Web services the following information command list should be referred for implementation ADAM 3600 A1F User Manual 52 B 2 REST Resources for ADAM 3600 A1F B 2 1 Digital Input B 2 1 1 di_value slot_index ch_num Description Retrieves information about the digital input value resource on specific slo
8. keep the module from sliding horizontally along the rail EELEE HORORE om wu EO iss CO om CH o em O D o Ho EO u KO za CO mu CO tm CH u en 2889P e ER PE 800009 pp 25025 200555 558205 585588 Figure 3 1 DIN Rail Installation ADAM 3600 A1F User Manual 12 3 2 2 Wall Mounted Installation F Figure 3 2 Wall Mounted Installation 3 2 3 Expansion Module Installation Figure 3 4 Expansion 1 0 Connector Installation 13 ADAM 3600 A1F User Manual 3 3 Wiring amp Connections This section introduces basic information on wiring the power supply I O units and Ethernet connection 3 3 1 Power Supply Wiring The ADAM 3600 A1F is designed for a standard industrial unregulated 24 Vpc power supply For further application it can also accept 10 to 30 Vpc of power input 200mV peak to peak of power ripple and the immediate ripple voltage should be maintained between 10 and 30 Vpc Screw terminals PWR and PWR are for power supply wiring 10 30 Vdc Figure 3 5 Power Supply Wiring Note The wires used should be at least 2 mm 3 3 2 Ethernet Daisy Chain Wiring The ADAM 3600 A1F module has built in Ethernet switches to allow daisy chain con nections in an Ethernet network making it easier to deploy and helping improve scalability The two Ethernet ports are fully compliant with IEEE 802 3u 10 100Mbpst through standard RJ 45 connect
9. output is in general DO mode The digital output is in Pulse output mode 33 ADAM 3600 A1F User Manual Users also can see the data trend in Value Trend area l Value Trend DI Logic Status All Ch 0 echi Ch2 Ch 1 value false timestamp 01 01 00 18 08 01 01 00 18 08 01 01 00 18 08 01 01 00 18 08 01 01 00 18 08 01 01 00 18 08 01 01 00 18 08 01 01 00 18 09 01 01 00 18 08 01 01 00 18 08 01 01 00 18 08 01 01 00 18 08 Previous Next Users also can see the data list in Data area Data v Show 10 M entries Log Type Timestamp UUID MAC Channel 128 2000 01 01T00 16 46 03 00 ADAM 3600 A1F 00D0C9FEFF39 00 D0 C9 FE FF 39 128 2000 01 01T00 16 46 03 00 ADAM 3600 A1F 00D0C9FEFF39 00 D0 C9 FE FF 39 128 2000 01 01T00 16 46 08 00 ADAM 3600 A1F 00D0C9FEFF39 00 D0 C9 FE FF 39 128 2000 01 01T00 16 46 08 00 ADAM 3600 A1F 00D0C9FEFF39 00 D0 C9 FE FF 39 0 1 2 128 2000 01 01T00 16 46 08 00 ADAM 3600 A1F 00D0C9FEFF39 00 D0 C9 FE FF 39 0 1 2 128 2000 01 01700 16 46 08 00 ADAM 3600 A1F 00D0C9FEFF39 00 D0 C9 FE FF 39 File Viewer Enable Media Storage Enable Storage EX Interface Storage Interface USB Thumb Data Format CSV Select Media Storage and choose the Media Log Configuration tab users can enable the data logger function in the external storage device and choose to use USB Thumb or SD card as the storage device In the field of Data Format you can see the data will be stored in CSV format
10. 003A60020 Edition 1 Printed in Taiwan September 2015 ADAM 3600 A1F User Manual Il Declaration of Conformity CE This product has passed the CE test for environmental specifications We recom mend the use of shielded cables FCC Class A Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Opera tion of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Technical Support and Assistance 1 Visit the Advantech web site at www advantech com support where you can find the latest information about the product 2 Contact your distributor sales representative or Advantech s customer service center for technical support if you need additional assistance Please have the following information ready before you call Product name and serial number Description of your peripheral attachments Description of your software operating system version application software etc A complet
11. Ch 2 Md 1 Stat 0 Val 3378 Cnting 0 CIrCnt 1 OvLch 0 Ch 3 Md 3 Stat 0 Val 0 Cnting 0 ClirCnt 0 OvLch 0 Response 200 OK Request PUT di_value slot_0 ch_2 Content type application json Ch 2 Md 1 Stat 0 Val 3378 Cnting 0 CIrCnt 1 OvLch 0 Response 200 OK 55 ADAM 3600 A1F User Manual Single Multiple Channel Request PATCH di_value slot_index Single Channel Request PATCH di_value slot_index ch_num Example Request PATCH di value slot 0 Content type application json d Diva d Ch 2 Cnting 1 Ch 3 OvLch 0 Response 200 OK Request PATCH di value slot O ch 3 Content type application json Ch 3 CIrCnt 1 Response 200 OK m JSON array name definition Array of Digital input configurations DIVal Array ADAM 3600 A1F User Manual 56 DI Resource value definitions Channel Number Ch Number 0 1 Digital input channel number Digital input mode 0 DI 1 Counter Mode Md Number R Low ToHighLatch HighToLowLatch BR WIN Frequency Signal Logic Status Stat Number R 1 0 Input signal is Logic High or Low DI measurement data Input Mode Value Description DI Logic Status of DI Counter Counter Value Channel Value Val Number H LowToHighLatch Logic status of DI HighToLowLatch Logic status of DI Frequency Frequency unity 0 1 Hz Start Sto
12. Device into your group You can also select Diagnose con nection to check the communication ADAM 4500_5510 Series This is a DOS interface utility for remote controllers such as ADAM 4500 and ADAM 5510 series Wireless Sensor Networks All wireless I O Modules ADAM 2000 modules connected to the host PC through wireless gateway will be listed in this category 4 3 1 4 Main Operation Screen Main Operation Screen located on the right side of utility includes I O status display and function setting You can select different items in Module Tree Screen and then Main Operation Screen will change dependently You can do all configurations and test in this area In Information page after clicking Ethernet you can configure Connection Send Receive Scan Timeout The supervisor password is a shortcut to let you enter a password at one time which s applied for certain modules so you don t need to enter the same password for each module when you check it ADAM 3600 A1F User Manual 40 4 4 Configuring ADAM 3600 A1F with ADAM NET Utility software ADAM NET Utility which is designed with graphical operation interface is aimed to offer users directly configure control and monitor the real time status of remote ADAM 3600 A1F module via Ethernet or Wireless connection To keep you informed with latest update you also can check it from the following download link on Advantech website http support advantech com tw Support Downl
13. SNTP Server watch stdtime gov tw You can enable the SNTP function so the module can act as a SNTP client to do time syn chronization from assigned SNTP server Modbus Configuration Information Network Network App Time amp Date SNTP Modbus Control General Firmware Account Modbus Address Mode Mode Default Address O Auto Allocate Coils Status 0X Holding Registers 4X In this page you can choose which Modbus address mode you want to use Default Address means apply the Modbus by the default setting Auto Allocate Address means the Modbus address will be allocated automatically Different from default Modbus address it will fill in the unused address Basically there re two kinds of Modbus address section 0X and 4X for you to configure each function item ADAM 3600 A1F User Manual 24 Control Configuration Information Network Network App Time amp Date SNTP Modbus General Firmware Account Control Locate Enabled Restore to Default Restore Reset Password Reset System Restart Restart Enable Locate It can help user search module with light sign Status LED will be on for 10 seconds after it s enabled Restore to Default The system configuration of the module will be cleared and restored to factory default after its clicked Reset Password You can reset the password here System Restart The system of this module will reboot after it s clicked General Configuration Information Network Network A
14. User Manual ADAM 3600 A1F Intelligent Remote I O Module AD ANTECH Enabling an Intelligent Planet Copyright The documentation and the software included with this product are copyrighted 2015 by Advantech Co Ltd All rights are reserved Advantech Co Ltd reserves the right to make improvements in the products described in this manual at any time without notice No part of this manual may be reproduced copied translated or transmitted in any form or by any means without the prior written permission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reliable How ever Advantech Co Ltd assumes no responsibility for its use nor for any infringe ments of the rights of third parties which may result from its use Acknowledgements Intel and Pentium are trademarks of Intel Corporation Microsoft Windows and MS DOS are registered trademarks of Microsoft Corp All other product names or trademarks are properties of their respective owners Product Warranty Advantech warrants to you the original purchaser that each of its products will be free from defects in materials and workmanship for two years from the date of pur chase This warranty does not apply to any products which have been repaired or altered by persons other than repair personnel authorized by Advantech or which have been subject to misuse abuse accident or improper installation Advantech assumes no liability und
15. Wireless Sensor Networks opo m ADAM 3600 A1F User Manual 42 If the ADAM 3600 A1F is not in the same domain as the computer after power up and searching for it in the utility the device name will been shown in the Others tree Users have to change the device network setting to the same domain with the computer in the page as below Then the module just can be accessed by the computer 2 Ed El I Serial i 3 COMI Setting i COM er Network 1 4 Ethemet Di ib 172 18 3 26 Ethemet Mode Configured g ee MAC addres 0 DO C9 FE FF 39 M 2600 A1F Static DHCP i IT Favorite Group per e E ADAM4500 5510Series 10 0 0 1 Port Number Setting D 65535 E Wireless BENSOT Networks me subnet Address 255000 Default gateway DO 00254 Apply change Others Locate Enable 43 ADAM 3600 A1F User Manual ADAM 3600 A1F User Manual 44 Appendix A 1 O Modbus Mapping Table A 1 Modbus Function Code Introduction To full fill the programming requirement there is a series of function code standard for user s reference Code Hex EE gt Read 16 bit register Used to read integer or floating point process data 05 Preset Single Register te data in 16bitiniegerfomai 08 Loopback Diagnosis Diagnosti testing ofthe communication port A 2 ADAM 3600 A1F Default Modbus Mapping Table The address value for each item is fixed regardless of the type or existence of
16. d Tab Local Viewer Query Format User can configure which kind of ID and the timestamp format will be logged here Query Filter This filter is for setting the criteria to query the logged data User can select the filter mode and click Query button to query the logged data 31 ADAM 3600 A1F User Manual Query Filter Filter Mode Time Filter Timestamp of the Oldest Ei 2015 05 19T16 22 12 Start Time ES 2000 01 01700 00 00 Timestamp of the Latest H 2015 05 19716 22 26 End Time 2020 01 01T00 00 00 There are two filter modes that they are Time filter and Amount of Latest Files Filter and File Format Filter If users selected Time Filter they can see the time stamps of the oldest data and the latest data in the storage device Then users can set the time period by setting Start Time and End Time This period has to be between the oldest timestamp and the latest time stamp Then they can query the data in the internal memory which the timestamps were in this period Query Filter Filter Mode Amount of Latest Data Current Total Amout 20819 Total Amout 500 If users selected Amount of Latest Files Filter they can see the total number of data with dif ferent timestamps in the internal memory at the field Current Total Amount Users can set how many records of data with different timestamps they want to query by setting the field Total Amount Note The data querying page had supported the data drawin
17. e description of the problem The exact wording of any error messages Ili ADAM 3600 A1F User Manual Safety Instructions 10 11 12 13 14 15 16 17 Read these safety instructions carefully Keep this User Manual for later reference Disconnect this equipment from any AC outlet before cleaning Use a damp cloth Do not use liquid or spray detergents for cleaning For plug in equipment the power outlet socket must be located near the equip ment and must be easily accessible Keep this equipment away from humidity Put this equipment on a reliable surface during installation Dropping it or letting it fall may cause damage The openings on the enclosure are for air convection Protect the equipment from overheating DO NOT COVER THE OPENINGS Make sure the voltage of the power source is correct before connecting the equipment to the power outlet Position the power cord so that people cannot step on it Do not place anything over the power cord All cautions and warnings on the equipment should be noted If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient overvoltage Never pour any liquid into an opening This may cause fire or electrical shock Never open the equipment For safety reasons the equipment should be opened only by qualified service personnel If one of the following situations arises get the equipment checked by service pe
18. el Contact Rating resistive load Max Switching Rate Breakdown voltage Relay operation time Mechanical Endurance Insulation Resistance 8 Form A 250 Vac 5A 30 Vpc 5 A 20 operations minute 500Vac 50 60Hz On 10ms Off 5ms 20 Million operations 1 GQ 500 Voc 9 ADAM 3600 A1F User Manual 2 3 2 Relay Output Wiring Contact rating 250 VAC 5A Resistive load 30 VDC 3A Figure 2 2 Relay Output Wiring 2 4 Pin Assignment Digital Input Relay Output Be ee a ee ee 0 0 1 1 2 2 3 3 4 4 5 5 6 6 7 7 Channel Symbol 0 j1 2 3 4 5 e 7 BP A B e E D IF Channel Number 0 1 2 s 14 js Je 7 8 Is jo 11 112 18 14 115 ADAM 3600 A1F User Manual 10 Chapter 3 Hardware Installation 3 1 3 2 3 2 1 Interface Introduction SD card Slot 16 ch Digital Input and LED status Device Node Switch 2 go Li e TS id a Dual RJ 45 Port ADAM 3600 I O Exapansion System LED Module Status USB Port Power Input 8 ch Relay Output and LED status Mounting ADAM 3600 A1F is designed as a compact unit and is able to be installed in the field site using the following methods DIN Rail Mounting The ADAM 3600 A1F can also be fixed to the cabinet by using mounting rails You need to assemble the DIN rail adapter to the module with flathead screw driver as below When the module is mounted on a rail you may also consider using end brackets at each end of the rail to
19. er the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most of our customers never need to use our repair service If an Advantech product is defec tive it will be repaired or replaced at no charge during the warranty period For out of warranty repairs you will be billed according to the cost of replacement materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem encountered For example CPU speed Advantech products used other hardware and software used etc Note anything abnormal and list any onscreen messages you get when the problem occurs 2 Call your dealer and describe the problem Please have your manual product and any helpful information readily available 3 If your product is diagnosed as defective obtain an RMA return merchandize authorization number from your dealer This allows us to process your return more quickly 4 Carefully pack the defective product a fully completed Repair and Replacement Order Card and a photocopy proof of purchase date such as your sales receipt in a shippable container A product returned without proof of the purchase date is not eligible for warranty service 5 Write the RMA number visibly on the outside of the package and ship it prepaid to your dealer Part No 2
20. es data processing and data logger functions to transmit truly useful data to the user These data can be access via mobile devices in anytime and anywhere 1 2 Feature Highlights 1 2 1 RESTful Web Service Integrated with HTML5 JavaScript and RESTful web service which satisfy the needs of IT technology and also open a new market for ADAM 3600 A1F This remote I O module will not only sell to automation SI but also the SI who has high level programming skill and network integration abilities 1 2 2 Data Storage Function File based cloud storage and data log function makes the data can be access at any time and in anywhere User will never need to care about how to collect the data into any data logger or data gateway 1 2 3 Access by Mobile Devices Direct mobile devices access functions make the information easier to been access With 3 levels security these data can storage access and publish in more safety way 1 3 Flexible UO deployment The ADAM 3600 can approach different scenarios by switching I O expansion mod ules Users can easily change and expand ADAM 3600 s I O deployment by applying on board I O and switching the I O expansion modules ADAM 3651 8 CH Digital Input Module ADAM 3656 8 CH Digital Output Module ADAM 3664 4 CH Relay Output Module ADAM 3600 A1F User Manual 2 1 4 Mechanical Design and Dimensions 1 4 1 ADAM 3600 A1F rri i E eessen 3 ADAM 3600 A1F User Manual 1 5 LED De
21. es in the Relay related pages that included Status Configuration and Trend ADAM 3600 A1F User Manual 28 Advanced Functions There are 3 advanced functions which contained Access Control Data Logger and Diagnosti cian Access Control t Advanced Function g Advanced Access Control For avoiding from unauthorized access this function provided manage which host PC or device has been permitted to remotely control module by IP or MAC Address Go to The status trend of 1 O will be shown here Data Logger Data Logger For easy retrieving history of data form device this function provided data logging and recording without programming Go to Diagnostics Diagnostician For diagnose the device this function provided organization status for specific function in device 29 ADAM 3600 A1F User Manual Access Control Q Access Control Enable Disable IPIMAC Ex 255 255 255 255 or 00 D0 C9 00 00 00 0 1 2 Enable one of the rows and enter the IP address or MAC address which allowed to access ing the ADAM 3600 A1F Data Logger Media Storage Local Log Configuration Enable Log Built In Storage Enable Storage CK Log Conditions By Period 1 Lei By Communication WOT Log D Clear Log when Power Up D Circular Log when Memory Full Go to Data Logger function select the item Data Log and choose the tab Local Log Con figuration User can comp
22. et address and default gateway in this page For DIP Switch IP mode users can set the IP address by setting the 6 bit DIP switch on the right up corner of ADAM 3600 A1F For example if the default IP is 192 136 0 38 and after you adjust the DIP Switch IP shown in the figure below the IP address will become 192 136 0 8 Note If the DIP switch was set to 0 it will keep the original IP address Dip Switch Network APP Configuration Information Network Time amp Date SNTP Modbus Network App Application Network Web Server Port Default 80 80 Hostidle Timeout 720 Communication WDT Trigger L Enable Disable Control General Firmware Account You can configure the web server port Host Idle timeout and decide whether to enable communication WDT here 23 ADAM 3600 A1F User Manual Local Time Configuration Information Network Network App Time amp Date SNTP Modbus Control General Firmware Local Time Current Time 2000 01 01700 42 55 08 00 Time Zone GMT 08 00 Taipei Time Calibration F Click Me You can see the current time here decide which time zone for your local time and also do the time calibration by read the time from host devices SNTP Configuration Information Network Network App Time amp Date SNTP Modbus Control General Firmware Account SNTP SNTP Time Polling Interval 3600 sec Enable SNTP Client Enabled Disabled Primary SNTP Server tock stdtime gov tw Secondary
23. exten sion I O slots Digital Input Default Coil Base 00001 Default Register Base 40001 DI Value Counter value Counter Start 1 addr ch 1 addr ch 00517 00532 mm hb Clear Over 00533 00548 0 15 2 flow RW 40235 40236 mr FW Build Ver 1 addr ch ADAM 3600 A1F User Manual 46 DI Latch Sta o0633 00688 Jas 2 us fam 40303 Divae Read 1 addr ch Digital Output Default Coil Base 01001 Default Register Base 41001 DO Value Pulse Output Low 1 addr ch 2 addr ch 01049 01064 0 15 R W 41097 41128 R W 01065 01080 0 15 R W 41129 41160 0 15 4 a R W bl 41301 A 41302 All R W 41303 All 2 DO Value R W 41304 All R W 41305 All R W 41401 41432 0 15 R 41433 41464 0 15 1 Pulse Output 0 15 High Level Width 2 addr ch 41601 41632 0 15 R W R gt 2 W R W R W 41633 41664 R W Set Absolute Pulse 2 addr ch R W 0 15 0 15 1 41665 41696 0 15 2 41697 41728 0 15 3 R W R W 41729 41760 R W 41801 41832 41833 41864 R W Set Incremental 41865 41896 0 15 Pulse R W 2 addr ch 41897 41928 0 15 R W R W 47 ADAM 3600 A1F User Manual A 3 Auto Allocated Modbus Address Case study Slot 0 16DI and 8DO Slot 1 8DI Slot 2 8DO Address 0X Slot Description Attribute Address 4X Slot Description Attribute Digital Input and GCL DI Value Counter value 00101 00116 pe de ni m ee ke Module
24. finition Indication Descrption Ge Module is working normall Run Green 0 5 second OFF g y 30 30secON 30sec ON When user enable LOCATE function Green Low Battery ed ON Low voltage of RTC battery Gre n Ethernet is connected Link Speed 1 Link 1 RW Ges TX RX is in transmission Speed 1 OFF Ethernet speed is at 10 Mbps Green ON etheretie connected M NW ON OFF ON Ethernet speed is at 100 Mbps Speed 2 OFF Ethernet speed is at 10 Mbps Li ON Logic 1 Digital Input Green ON OFF OFF Logic 0 ON Logic 1 Relay Output ON OFF OFF Logic 0 ADAM 3600 A1F User Manual 4 1 6 Certification and Safety Standards FCC FCC 47 CFR PART 15 Class A IC ICES 003 CE EN 55011 55022 Class A EN 61000 6 4 EN 61000 3 2 EN 61000 3 3 EN 55024 EN 61000 6 2 IEC 61000 4 2 IEC 61000 4 3 IEC 61000 4 4 IEC 61000 4 5 IEC 61000 4 6 IEC 61000 4 8 IEC 61000 4 11 RoHS China RoHS WEEE ADAM 3600 A1F User Manual ADAM 3600 A1F User Manual Chapter 2 Product Specifications 2 1 General Specification LAN Interface m Ethernet IEEE 802 3u 10 100Base T X H Connector 2 port RJ 45 General H Watchdog Timer System 1 6 second Communication Programmable H Mounting DIN 35 rail wall mount E External Storage Interface 1 x USB2 0 Port Maximum supported storage capacity 32GB 1 x Standard SD Card Slot Maximum supported storage capacity 32GB Operation Te
25. g function However if there were too much data had been drawn on the web page it would cause the web browser at the state of over loading Thus we set the limitation that there were about 5000 points of I O data could be queried one time For example once the user entered a number 1000 at the field Total Amount that meant the user want to query 1000 records of data with different timestamps If each record of data contained 6 points of I O data then the total number of I O points would be 6000 That exceeded the limitation The user would see the notification message shown below Notification The result will be provided amount of 534 latest dates for manipulation due to the browser resource limitation ADAM 3600 A1F User Manual 32 IW 1O Type Statistic Log Type Proportion 10 Type DI Logic Status Log Type M IO Type Bar Chart DI Logic Status DI Logic Status DI Counter Value DO Logic Status After clicking the button Query users can see the graphic at IO Type Statistic area which recorded the numbers of data with different I O types The proportion of data for each log way Event or Periodic also would be drawn at Log Type Proportion area The explanation of 1 O Type is indicated in the form below Users also can see the data trend in Value Trend area I O Type Description 1 The digital input is in general DI mode The digital input is in Counter mode The digital input is in Frequency mode The digital
26. he Web It will automatically connect to support and download page of Advantech web site when it enabled You can find and download the latest version of ADAM 3600 A1F utility there About ADAM NET Utility The current version of ADAM NET Utility is installed on your computer 39 ADAM 3600 A1F User Manual 4 3 1 2 Toolbar There are 8 graphical icons for common used options of Menu on the toolbar SEER s bb Definition from left to right Open favorite group Save favorite group Search Modules Add Devices to Group Terminal for Command Testing Group Configuration Monitor Data Stream Event Print Screen EE Mam 4 3 1 3 Module Tree Screen The Module Tree Screen locates on the left part of ADAM NET utility operation win dow There are four categories in this area Serial All serial YO Modules ADAM 4000 and ADAM 5000 RS 485 serial modules con nected to the host PC will be listed in this category Ethernet All Ethernet 1 0 Modules ADAM 6000 ADAM 6100 ADAM 5000 TCP and ADAM 3600 A1F connected to the host PC will be listed in this category Favorite Group You can define which devices listed in the three categories above into your personal favorite group This will make you easier to find your interested modules Right click on the ADAM 3600 A1F item under the Favorite Group item and you can select Add New Group to create a new group After you create your own group right click on your group and Add New
27. ite group After activat ing search function all online modules will show on Module Tree Screen area Now you can enable this function to select the device you want to add in the Module Tree Screen Group Configuration Group Configuration is on ADAM 3600 A1F module It can help you efficiently configure or maintain massive ADAM 3600 A1F modules with the same config uration file or firmware upgrade at one time in the local network The following steps will instruct you how to operate it Terminal for Command Testing The ADAM 3600 A1F module Modbus TCP as communication protocol so you can launch the terminal to directly communicate with ADAM 3600 A1F module by these two protocols Print Screen You can save current ADAM NET Utility screen into an image file by this option ADAM 3600 A1F User Manual 38 c Setup Q Help Favorite Group You can configure your favorite group including add one new device modify or delete one current device sort current devices and diagnose connection to one device Refresh Serial and Ethernet ADAM NET utility will refresh the serial and LAN network connection situation Add COM Ports This option is used to add serial COM ports in ADAM NET Utility You won t need to use this option for ADAM 3600 A1F modules Show TreeView Check this option to display the Module Tree Screen area Allow Calibration Check this option to allow calibration function enabled on Al O module Check Up to Date on t
28. lete the setting for Data Logger function Enable Log Decide whether to enable data log function here Built In Storage Decide whether to enable the built in storage memory here Log Conditions The log period can be decided in By Period box Pleased been noted that the period is increased by 0 1seconds It means if user set 600 here the status of the I O will be logged each minute Otherwise If the communication WDT been enable and user also choose By Communication WDT Log once the condition of WDT had been met the status of I O will be logged General Decided whether to clear the logged data when power up by choosing the option Clear Log when Power Up Otherwise decide whether to execute circular log when the memory is full by choosing the option Circular Log when Memory Full ADAM 3600 A1F User Manual 30 Log Data Channel Fields Channel Settings IO Type ED Slot 1 Slot 2 Slot 3 Slot 4 Enabled Channel Change of State Al Users can configure which channels of the module in each slot will be logged and decide whether to log the data when the I O status is changed by check the box of Change of State Data Log Media Storage Local Log Configuration Local Viewer Query Format v UUID M Enabled Disabled Enabled Disabled Timestamp Coordinated Universal Time UTC Query Filter v Filter Mode No Filter Enable
29. mperature 40 70 C 40 158 F Storage Temperature 40 85 C 40 185 F Operating Humidity 20 95 RH non condensing Storage Humidity 0 95 RH non condensing Note Equipment will operate below 30 humidity However static electricity problems occur much more frequently at lower humidity levels Make E sure you take adequate precautions when you touch the equipment Consider using ground straps anti static floor coverings etc if you use the equipment in low humidity environments Power m Power Input Voltage 10 30 Vpc 24 Voc Standard Software Configuration Interface Web Interface Windows Utility Driver ADAM APAX NET Class Library Industrial Protocol Modbus TCP Supported Protocols TCP IP UDP HTTP DHCP ARP SNTP Supports RESTful Web API in JSON format Supports Web Server in HTML5 with JavaScript amp CSS3 Reset Button Users can push the Reset button on the left panel of the ADAM 3600 A1F to reboot the system directly ADAM 3600 A1F User Manual 8 2 2 Digital Input 2 2 1 Digital Input Specifications Channel Wet Contact Uni direction 16 Logic 0 0 5 Voc Logic 1 10 30 Vic Isolation Protection 2500 Voc Max Input Frequency 3 kHz Max Counter Frequency 3 kHz 2 2 2 Digital Input Wiring 07 e Weg Note If using the DI channels 8 F users have to use GND as the DI ground Figure 2 1 ADAM 3600 A1F Digital Input Wiring 2 3 Relay Output 2 3 1 Relay Output Specifications Chann
30. nt ADAM 3600 A1F User Manual 36 4 3 Configure ADAM 3600 A1F with ADAM NET Utility 1 Install ADAM NET Utility in your computer After successfully installation there will be a shortcut generated on the screen Double click the shortcut icon and then you will see the main operation window Click Search Module icon in Toolbar You will see all online modules in the left Module Tree screen and an unconfigured new module whose default password is 00000000 will appear on the Others section as below Now you can define the network mode of the module in the beginning After that you will be able to perform other settings The default password is 00000000 4 3 1 Operation Framework The operation window mainly contains 4 areas including Menu Toolbar Module Tree screen and Main Operation screen 4 3 1 1 Menu a File E Open Favorite Group You can import the favorite configuration group file XML from your computer m Save Favorite Group You can save the favorite group configuration group as XML file to your com puter Auto Initial Group If you want to have the same favorite group configuration when you exit ADAM NET utility and launch it again you need to check this option E Exit Exit ADAM NET Utility 37 ADAM 3600 A1F User Manual b Tools Search Device Search all the ADAM 3600 A1F modules you connected in local Ethernet Add Devices to Group It s used to add ADAM 3600 A1F modules to your favor
31. oadSRDetail aspx SR_1D 1 2AKUDB Before installing ADAM NET Utility you need to install NEI Framework 2 0 or higher version System requirement Microsoft Windows XP 7 At least 32 MB RAM 20 MB of hard disk space available VGA color or higher resolution monitor Mouse or other pointing devices 10 100 Mbps or higher Ethernet Card 1 Configure the computer s IP address as the same domain as ADAM 3600 A1F module For the new ADAM 3600 A1F which default IP address is 10 0 0 1 the IP address of computer can be configured as 10 0 0 99 for example as follow ing 2 Open the Adam Apax NET Utility then you can see the IP address of computer been shown under Ethernet tree You can right click to refresh the subnodes of this tree Or click Search Device to find ADAM 3600 A1F module File Tools Setup Help DHS Fb e Information Search Device Host name Wee Refresh Subnodes Adapter 10 0 0 99 Connection timeout 2000 m send timeout 2000 ms Receive timeout 1000 m scan interval 1000 m Supervisor password 3 Users can also right click the IP address to find ADAM 3600 A1F File Tools Setup Help CO Ro F Adapter 10 0 0 99 Connection timeout 2000 ous 41 ADAM 3600 A1F User Manual 4 9 7 After the module been found it will be listed under IP address in same domain you can login the embedded web configuration web page for further configura tion as introd
32. onfigurations 61 ADAM 3600 A1F User Manual H Resource value definitions Field Abbreviation Data Type Property Description Channel Number Ch Number R 0 1 Digital output channel number Digital output mode 0 DO 1 Pulse Output Mode Md Number R 2 LowToHighDelay 3 HighToLowDelay Signal Logic Status Stat Number R 1 0 Output signal is Logic High or Low DO measurement data Output Mode Value Description DO Get the current signal status or set its status Channel Value Val Number RW POSE Get or set the absolute pulse count value Low ToHighDelay Get the current signal status or set its status HighToLowDelay Get the current signal status or set its status Pulse Output Continue State PsCtn Number RW 1 0 Pulse outputting is continuous or not 1 Stop the pulse outputting Stop Pulse Output PsStop Number W Continue is disabled Absolute and incremental values are reset to zero DO signal status is set to logic low DEES SE PsIV Number RW Incremental Pulse Output Value put Value ADAM 3600 A1F User Manual 62 63 ADAM 3600 A1F User Manual AD ANTECH Enabling an Intelligent Planet www advantech com Please verify specifications before quoting This guide is intended for reference purposes only All product specifications are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without p
33. onnect the ADAM 3600 A1F to your local Ethernet network then open the browser of your computer or mobile device Enter IP address of module with config for example the default URL http 10 0 0 1 config Then you will see the login page please enter the account and pass word then click Login button After login you will see the Informa tion page Scroll down the tab you can change the login user here You can switch to other pages by choosing the selection item at the left side of the Web page Information Page 1 In the information page you can see the three dashboards Module Network and Module Information 2 Click Go to Configuration to perform the configuration D Module Model Name ADAM 3600 A1F Customized Name ADAM 3600 A1F UUID ADAM 3600 A1F 00DOC9FEFF39 Location Description Go to Configuration Users can view the basic information of the module Users can view Module ID Custom ID Location and Description of the module Network Mac 00 D0 C9 FE FF 39 IP 10001 Subnet 255 0 0 0 Gateway 0 0 0 0 IP Mode Static DHCP Dip Switch IP Go to Configuration Users can view the Network information of the module Module Information Slot Module Name Module Description Firmware Description ADAM 3600 A1F 16 channels digital input 8 channels relay output Fw A0 08 B02 Bootloader A0 00B01 Users can see which expansion modules are installed in the ADAM 3600 A1F
34. ors Figure 3 6 Ethernet Daisy Chain Wiring ADAM 3600 A1F User Manual 14 3 3 3 UO Units The system uses a plug in screw terminal block for the interface between IC mod ules and field devices The following information must be considered when connect ing electrical devices to I O modules 1 id eN The terminal block accepts wires from 0 5 mm to 2 5 mm Always use a continuous length of wire Do not combine wires Use the shortest possible wire length Use wire trays for routing where possible Avoid running wires near high energy wiring Avoid running input wiring in close proximity to output wiring Avoid creating sharp bends in the wires 15 ADAM 3600 A1F User Manual ADAM 3600 A1F User Manual 16 Chapter 4 System Configuration 4 1 Connection 1 Plug DC power source in Power Power pin of ADAM 3600 A1F module and turn the power on 2 Connect your computer to Ethernet port of ADAM 3600 A1F module with RJ 45 cross over Ethernet cable 4 2 Configure the ADAM 3600 A1F with the Web Interface 4 2 1 System Requirements The module is developed by public HTML 5 base but for detailed indication and data transmission mode may be different on Web page of the operating system For mobile devices the minimum requirement of web browsers as below m Safari 6 in Apple iOS H Web Browser in Google Android 4 0 Ice Cream Sandwich E Chrome in Google Android 4 0 Ice Cream Sandwich Configuration Data
35. p counter counting Read 1 counter is counting Start Counter Cnting Number RW 0 not counting Write 1 start counting 0 stop counting Clear Counter CirCnt Number W 1 Clear the counter value counter overflow or latch status Read 1 overflow latch occurred 0 no overflow or latch Write 0 clear the overflow or latch status Get Clear Counter Overflow or Latch Sta OvLch Number RW tus 57 ADAM 3600 A1F User Manual B 2 2 Digital Output B 2 2 1 do_value slot_index ch_num Retrieves information about the digital output value resource on specific slot http 10 0 0 1 do_value slot_index Ss http 10 0 0 1 do value slot index ch num GET Returns the representation of all of digital output value resource PUT Replace all of digital output value resource PATCH Apply partial modifications to digital output value resource HTTP Method ADAM 3600 A1F User Manual 58 GET Multiple Channel Request GET do value slot index Single Channel Request GET do value slot index ch num Example Request GET do value slot 0 Content type application json Response 200 OK d DOVal Ch 0 Md 0 Stat 1 Val 1 PsCtn 0 PsStop 0 PsIV 0 Ch 1 Md 0 Stat 0 Val 0 PsCtn 0 PsStop 0 PsIV O Ch 2 Md 1 Stat 1 Val 3378 PsCtn 0 PsStop 0 PslV 0 Ch 3 Md 3 Stat 1 Val 1 PsCtn 0 PsStop 0 PsIV 0 Re
36. page too ADAM 3600 A1F User Manual 26 UO Configuration Configuration Configuration Channel Tag Name DI 0 Mode DI v All datas will be cleared in the data logger if change the Mode Invert Signal M Enabled Disabled Digital Filter M Enabled Disabled Min Low Signal Width 0 1ms Max Low Signal Width 1 0 1ms User can do detail I O setting in the configuration tab that include the Tag Name Invert Sig nal enable Digital Filter and also the working mode of each channel Overview Channel Tag Name Parameter DI Inv 0 Fitr 0 FtHi 1 FiLo 1 DI Inv 0 Fitr 0 FtHi 1 FtLo 1 DI Inv 0 Fitr 0 FiHi 1 Filo 1 DI 3 DI Inv 0 Fitr 0 FiHi 1 FtLo 1 DI 4 DI Inv 0 Fltr 0 FiHi 1 Filo 1 DI 5 DI Inv 0 Fltr 0 FiHi 1 FiLo 1 DI 6 DI Inv 0 Fitr 0 FiHi 1 Filo 1 In the end there is an overview table for the configuration summary of each channel Trend Status Configuration DI Trend DI_Ch0 DI Chi DI_Ch2 DI_Ch3 DI Ch4 DI_Ch5 DI_Ch6 DI_Ch7 DI_Ch3 DI_Ch9 DI_Ch10 DI_Ch11 DI_Ch12 DI_Ch13 DI Ch14 DI Ch15 The status trend of I O will be shown here 27 ADAM 3600 A1F User Manual Relay setting o Configuration Status Configuration Channel Tag Name Mode v All datas will be cleared in the data logger if change the Mode Refresh v Refresh FSV True False The user can also check and change the local Relay output status
37. pp Time amp Date SNTP Modbus Control Firmware Account General Configuration Scan Interval 1000 FSV by Communication WDT M Enabled Disabled Note Each IO will switch to it s FSV if the module s WDT is enabled and it gets triggerd You can set the Scan interval in this page After Communication WDT has been enabled in Network App tab you can enable the IO FSV triggered by communica tion WDT Firmware Update Network App Time amp Date SNTP Modbus Control General Account Firmware User Web Page You can upgrade the firmware and the Web page here 25 ADAM 3600 A1F User Manual Account Configuration Information Network Network App Time amp Date SNTP Modbus Control General Firmware Account Password Authority Change Password Read Write Admin amp Change Password Read Write User a Change Password Read You can change the passwords of each account here I O Status Il ADAM 3600 A1F Slot 0 Status Slot 0 ADAM 3600 Configuration A1F Status Channel Choose the I O Group tab then the user will see the option Slot0 ADAM 3600 A1F Click it the onboard I O statuses are shown in this page For the output status you can also change the I O status here If ADAM 3600 A1F has been installed with expansion I O mod ules then the user will see the other options which corresponding to the expansion I O mod ules They can check and change the I O statuses of the expansion modules in that
38. quest GET do value slot O ch 2 Content type application json Response 200 OK Ch 2 Md 0 Stat 1 Val 1 PsCtn 0 PsStop 0 PslV 0 59 ADAM 3600 A1F User Manual PUT ADAM 3600 A1F User Manual Single Multiple Channel Request PUT do_value slot_index Single Channel Request PUT do_value slot_index ch_num Example Request PUT do value slot 0 Content type application json d DOVal Ch 0 Md 0 Stat 1 Val 1 PsCtn 0 PsStop 0 PsIV 0 Ch 1 Md 0 Stat 0 Val 0 PsCtn 0 PsStop 0 PsIV 0 Ch 2 Md 1 Stat 1 Val 3378 PsCtn 0 PsStop 0 PslV 0 Ch 3 Md 3 Stat 1 Val 1 PsCtn 0 PsStop 0 PslV 0 Response 200 OK Request PUT do_value slot_0 ch_2 Content type application json Ch 2 Md 2 Stat 0 Val 0 PsCtn 0 PsStop 0 PsIV 0 Response 200 OK 60 Single Multiple Channel Request PATCH do value slot index Single Channel Request PATCH do value slot index ch num Example Request PATCH do value slot 0 Content type application json soa Ch 2 Md 2 Ch 3 PsStop 1 Response 200 OK Request PATCH do value slot O ch 3 Content type application json d Ch 3 PsCtn 1 Response 200 OK m JSON array name definition Field Abbreviation Data Type Array of Digital input DOVal Array c
39. rior written permis sion of the publisher All brand and product names are trademarks or registered trademarks of their respective companies Advantech Co Ltd 2015
40. rsonnel The power cord or plug is damaged Liquid has penetrated into the equipment The equipment has been exposed to moisture The equipment does not work well or you cannot get it to work according to the user s manual The equipment has been dropped and damaged The equipment has obvious signs of breakage DO NOT LEAVE THIS EQUIPMENT IN AN ENVIRONMENT WHERE THE STORAGE TEMPERATURE MAY GO BELOW 20 C 4 F OR ABOVE 60 C 140 F THIS COULD DAMAGE THE EQUIPMENT THE EQUIPMENT SHOULD BE IN A CONTROLLED ENVIRONMENT CAUTION DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY REPLACED REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE RECOMMENDED BY THE MANUFACTURER DISCARD USED BATTERIES ACCORDING TO THE MANUFACTURER S INSTRUCTIONS The sound pressure level at the operator s position according to IEC 704 1 1982 is no more than 70 dB A DISCLAIMER This set of instructions is given according to IEC 704 1 Advantech disclaims all responsibility for the accuracy of any statements contained herein ADAM 3600 A1F User Manual IV Contents Chapter 1 N ak O I Chapter 2 2 1 2 2 2 3 2 4 Chapter 3 3 1 3 2 3 3 Chapter 4 4 1 4 2 Product Overview aaannnnn n aursxt nnnnuum I Ta 810 10 0 e g RE 2 Feature elei e lu EE 2 1 2 1 RESTful Web Service 2 1 2 2 Data Storage Function enke kernen nenne nennen 2 1 2 3 Access by Mobile
41. t http 10 0 0 1 di_value slot_index PR SEE http 10 0 0 1 di value slot index ch num GET Returns the representation of all of digital input value resource HTTP Method PUT Replace all of digital input value resource PATCH Apply partial modifications to digital input value resource 53 ADAM 3600 A1F User Manual Multiple Channel Request GET di_value slot_index Single Channel Request GET di_value slot_index ch_num Example Request GET di_value slot_0 Content type application json Response 200 OK d DIVal Ch 0 Md 0 Stat 1 Val 1 Cnting 0 CirCnt 0 OvLch 0 Ch 1 Md 0 Stat 0 Val 0 Cnting 0 CirCnt 0 OvLch 0 GET Ch 2 Md 1 Stat 0 Val 3378 Cnting 1 CirCnt 0 OvLch 0 Ch 3 Md 3 Stat 0 Val 1 Cnting 0 ClrCnt 0 OvLch 0 Request GET di value slot O ch 2 Content type application json Response 200 OK Ch 2 Md 0 Stat 1 Val 1 Cnting 0 ClrCnt 0 OvLch 0 ADAM 3600 A1F User Manual 54 PUT Single Multiple Channel Request PUT di_value slot_index Single Channel Request PUT di_value slot_index ch_num Example Request PUT di_value slot_0 Content type application json d DIVal Ch 0 Md 0 Stat 0 Val 0 Cnting 0 CirCnt 0 OvLch 0 Ch 1 Md 0 Stat 0 Val 0 Cnting 0 CIrCnt 0 OvLch 0
42. uced in previous section D cal Serial i a COMI x GA Ethernet ADAM 3600 Config Web ERZ 10 0 0 99 CI Favorite Group Password EHE ADAM4500 5510 eries E Wireless Sensor Networks a There are some function provide in same pages in utility first you can enter the account and password faster in Login Info tab G Serial Login Info O Device Info EF QR 3 ee root mj COM2 GO Ethernet e 3600 Config Web i E 100099 RON i A 10 0 0 1 A DAM 3600 41F ce B Favorite Group Password HPA ADAM4500_5510Series Se Li din Wireless Sensor Networks In the Device Info tab the detail information of this module will been shown J E Serial 3 2 Device Name ADAM 3600 A1F 1 4el Ethernet Device Description Ad 10 00 99 Firmware Version A0 08 BO2 dg 10 0 0 1 ADAM 3600 A1F MAC Address 00 D0 C9 FE FF 39 oo IP Address 10 0 0 1 n Favorite Group J St ADAM450D 5510 eries Subnet Se Ie Wireless Sensor Networks Default Gateway 10 0 0 254 http 10 0 0 1 80 confi The QR tab will generate the QR code of the web configuration web page for mobile device to access the module User can also click the QR code to open the browser for further configuration cm Serial F 2 DIS OR a com 4 Login Info Q Device Info BE OR M COM E Ethemet Ey 10 0 0 99 AN 10 0 0 1 TADAM 3600 A when scanning OR code you will automatically be e x SE taken to the module website URL in IT Favorite Group EI U ADAM4500 55108eries Li dh

Download Pdf Manuals

image

Related Search

Related Contents

Installation/User Manual  PA210/400  Typhoon User Manual  Homelite VERSALITE UT41002 User's Manual  Amana *D(H Furnace User Manual  Prisma HD User Manual  MINISTÉRIO DO TRABALHO E EMPREGO  Purple Octopus user manual  

Copyright © All rights reserved.
Failed to retrieve file