Home
VV-TG001A-EN-P, VersaView Installation and Troubleshooting Guide
Contents
1. com locations index html How to run the utility To run the diagnostic utility insert the green VersaView Support CD into the computer s CD ROM drive and reboot the computer No software will be installed nor will the utility affect any software already installed If your computer does not have a CD ROM drive you may run the diagnostic utility from a floppy disk a USB CD ROM drive or a USB removable storage device gt Component Maintenance gt Installation Recommendations INDUSTRIAL COMPUTING www ab com versaview Troubleshooting HOME TEMPERATURE DIAGNOSTICS 6181P 6181F 6180W 6155R 6186M The power supplies included on all VersaView industrial computers and monitors are designed and tested to ensure that they will weather short term sags in or losses of line voltage Long term power disruptions excessive high transient voltages and uncontrolled power cycling may cause unreliable operation If you encounter problems with your VersaView equipment and suspect power is the source of those problems consider the following list of common power culprits Uncontrolled power cycles Your VersaView computer s power should be switched off only through the switch on the computer chassis an attached uninterruptible power supply UPS or the Windows Start menu To determine if your VersaView computer has been subject to unplanned power shutdowns check the system log which is found by going to the Windows start menu
2. gt settings gt control panel gt administrative tools gt event viewer Any event with the identification number 6009 is a shutdown Check the time stamp on each shutdown to ascertain whether each happened at a planned time If your VersaView computer is experiencing problems and you determine that it has been subject to multiple uncontrolled power cycles the computer should be re imaged You also should follow the power guidelines in the installation section to stop the uncontrolled power cycling which can cause damage to your hard drive and shorten your computer s life Power dropouts No computer can operate properly in the presence of current waveforms power surges power sags power dropouts harmonic distortion or other power quality problems Power line monitoring equipment is the best way to detect these problems The monitoring equipment runs unattended and is capable of recording and storing waveforms for you to review thereby enabling you to assess the general quality of the power installation AEMC Instruments and Dranetz BMI offer high quality power monitoring equipment 6155R CONTINUED VW gt Component Maintenance gt Installation Recommendations INDUSTRIAL COMPUTING www ab com versaview Troubleshooting HOME TEMPERATURE DIAGNOSTICS 6181P 6181F 6180W 6155R 6186M If your VersaView computer s line is characterized by voltage sags dropouts or high levels of transient energy
3. Automation factory image Clone an external image of the hard drive in its out of the box state This provides you with a clean factory image of your computer in case you experience a problem installing applications If your VersaView computer has a rotating media hard drive it shipped with a spare copy of the factory image on a recovery partition within the hard drive 2 Final application image Clone an external image of the final application image A DVD of your final image will enable you to restore any similar VersaView computers for immediate use in your application CONTINUED Y HOME Cloned images have multiple uses If improper or unplanned shutdowns or other unexplained errors affect the image on your hard drive cloned images easily can be loaded to minimize downtime on your production floor Please note that cloned images can be transferred only to VersaView computers with the same attributes e g touch screen DVD CD RW screen resolution etc as the original cloned machine Furthermore if there have been significant technological changes to a computer previous cloned images might not transfer properly One example of a significant technological change is a change in motherboard indicated by a series change to the VersaView computer line Turn off your computer There are many advantages to turning off your VersaView industrial computer at regular intervals hopefully for at least 15 minutes per day First tu
4. before you deploy the computer in its intended application There is no limit to the number of times an image can be created Each time a backup is made the new image replaces the old image OTHER APPLICATION CONSIDERATIONS Operating systems The VersaView computer s Microsoft operating system has been configured for optimal performance in an industrial environment Everything you need to load and run your application has been configured for you In addition the Windows operating system has been pre activated so you dont need to register your license through Microsoft HOME POWER TEMPERATURE MOUNTING There are times however when you might need to configure your own operating system image On those occasions use the included Recovery CD and Accessory CD which contain the needed drivers Solid state hard drives If your VersaView industrial computer relies on a solid state hard drive it is imperative that you do not turn on the virtual memory system restore or hibernation functions These have been disabled intentionally in order to maximize the number of times you are able to write to your solid state drive Hard disk drives Hard disk drives are a common source of computer failures because they contain small moving parts and they are susceptible to higher temperatures The VersaView computers are designed to mitigate the common causes of hard drive issues However to insure maximum reliability you must caref
5. chassis Improper power cycling may lead to corruption of the operating system or damage to the rotating media disk drive The computer should not be powered through a disconnect used to shut down other equipment Ideally the computer should be powered from a circuit with a separate disconnect Avoid powering the VersaView computer from noisy locations When installing your VersaView computer ensure the computer s power wiring does not lie close to circuits that may fall victim to heavy switching transients such as those induced by motors welding equipment or other heavy equipment If clean power is not available use an uninterruptible power supply UPS to protect the computer from improper shutdowns power outages surges and bad harmonics Ensure proper grounding To ensure an electrically safe installation connect your VersaView product to earth ground when installed Installing the computer or monitor in a panel enclosure or rack already connected to earth ground satisfies this requirement Please note that even if your VersaView computer s power cable is grounded properly the computer still may receive noise from a nearby enclosure or panel that is not properly grounded To ensure the safe and reliable performance of your VersaView product make sure its power source its enclosure and any neighboring equipment are properly grounded Refer to your VersaView user manual for additional information 6155R gt Troubleshoot
6. drive INDUSTRIAL COMPUTING www ab com versaview Component Maintenance Recommendations Scandisk and Chkdsk utilities Scandisk in Windows 2000 or Chkdsk in Windows XP are utilities supplied by the Windows operating system They check for physical errors on the surface of the hard drive and attempt to correct any errors found Be sure to run Scandisk or Chkdsk if you experience any problems with your hard drive Defragmenting your hard disk drive Over time the files on your hard drive will scatter apart due to frequent copying moving and deletion of files Defragmenting realigns the scattered file pieces allowing your hard drive to access files more quickly and even reclaiming lost hard disk space Use the Windows utility Disk Defragmenter at least once per month OPTICAL AND FLOPPY DRIVES Operate in a clean environment The best preventive maintenance for optical or floppy drives is to operate the drives in a clean environment Also never leave disks inserted in the drive when not in use and always store disks in protective carriers Drive diagnostics If you experience any problems with your computer s optical or floppy drives your VersaView computer can help you figure out what is wrong All VersaView industrial computers ship with a green System Support CD part number 77184 927 99 This bootable CD contains a diagnostic program able to find problems on your overall system without booting up into the Wi
7. ship with a cloning utility that easily allows you to make a back up of your application This critical step should be a mandatory part of any installation MOUNTING VersaView industrial computers offer a ruggedized computing solution that can tolerate robust environmental conditions The proper mounting of the computer will improve its useful life Proper mounting includes elements such as enclosure locations ventilation cleanliness and power considerations gt Troubleshooting 7i w INDUSTRIAL COMPUTING www ab com versaview Installation PE TEMPERATURE PC Ri APPLICATION MOUNTING 6181P 6181F 6180OW 6155R 6186M Industrial computers and monitors require clean and reliable power for proper operation Even though the industrial computer s power supply is less susceptible to problems there are some precautions that should be taken in order to keep even an industrial computer running properly Poor power can lead to system troubles manifested in ways that would not lead one to suspect power issues as the cause Taking some steps to improve the quality of the power going into the system can help prevent problems Avoid improper power cycles During installation of your VersaView computer make sure the product is not exposed to uncontrolled power cycling The computer should be turned off only through the shut down command in the start menu or by pressing the power switch on the computer
8. 6 Publication VV TG001A EN P November 2005 Copyright 2005 Rockwell Automation Inc All Rights Reserved Printed in USA
9. VERSAVIEW INSTALLATION AND TROUBLESHOOTING GUIDE INDUSTRIAL COMPUTING MEET VI C Welcome to the world of Rockwell Automation Industrial Vi Vi Industrial Computing Rockwell Automation is committed to providing you your Versaview Inausiria Computing Tour Guide with a simple buying experience an innovative high performance portfolio of solutions a strong global support network and above all a quality product that provides years of reliable service For the past century Allen Bradley products have been the world class leaders in product quality Today the Rockwell Automation Industrial Computing team carries on that Allen Bradley tradition by striving to continuously improve the VersaView industrial computer and monitor portfolio Just as your automobile needs proper maintenance and care to deliver reliable performance so does your industrial computing solution This publication is intended to provide a high level awareness of the critical considerations that must be reviewed during the installation and maintenance of your industrial computing solution Additionally a troubleshooting section has been added to assist you in the event that an issue arises Rockwell Automation s Global Manufacturing Solution business offers a suite of installation application and maintenance services that insure you derive the maximum value from your automation solution Please remember to contact Rockwell Automation s Technica
10. capable of providing sufficient current when powering on without a reduction in output voltage When powering on VersaView computers draw an inrush current as high as 20 amperes for five milliseconds If your line supply voltage drops during these intervals your VersaView computer may be sensing an undervoltage condition prompting it to shut down It will appear as though the computer will not power up Use a power line monitor or an oscilloscope to determine whether the line supply voltage remains within rated limits when your VersaView computer is powering on If the line supply cannot maintain its rated voltage it should be replaced by a supply with greater capacity 6155R For additional information on power requirements please refer to your VersaView user manual gt Component Maintenance gt Installation Recommendations INDUSTRIAL COMPUTING www ab com versaview Troubleshooting HOME TEMPE RATU RE 6181P 6181F 6180W 6155R 6186M When attempting to understand your applications temperature characteristics it s important to monitor the environment in a production atmosphere The enclosure door should be closed and you must allow adequate time for the enclosure to reach its steady state internal temperature Other equipment also in the enclosure must be powered and under load conditions to simulate a worse case situation Also make sure to consider the temperate fluctuations that may exist through the
11. course of the day 2 00pm may be a hotter condition then 8 00am Rockwell Automation s Global Manufacturing Solution business offers a suite of application services that will assist you in determining your application s environmental characteristics If your computer has the potential to be exposed to high temperatures even those in the upper range of the product specification we have the following recommendations e Consider a solid state drive storage media device versus the standard rotating media hard disk drive SSD s are much less susceptible to long term heat exposure e Consider adding a fan to the enclosure that would bring the temperature well below the specified limit This solution should only be entertained if the environment is contamination free Blowing debris across the electronics 6180W especially conductive dust will only make the situation worse KR e Consider adding an enclosure air conditioner e Consider moving other heat causing equipment out of the computer enclosure 6155R gt Component Maintenance gt Installation Recommendations INDUSTRIAL COMPUTING www ab com versaview Component Maintenance Recommendations Computers make use of some of the most sophisticated hardware technology available However due to the simple interfaces offered by today s operating systems and software packages many users forget about or do not realize the need for periodic hardwa
12. eplacement Check that the fan filters are clean and able to provide proper airflow to the VersaView computer system If your application contains considerable contaminants you should schedule regular preventive maintenance checks on the fan filters Rockwell Automation offers replacement fan filters when you need them DISPLAYS Screen cleaning Displays can be cleaned with ethyl alcohol methyl alcohol cleaning naptha commercial glass cleaners or ammonia in a 10 diluted solution Displays and touch screens are resistant to these chemicals Backlight replacement Improvements in display technology have greatly extended the half brightness hour rating of the CCFL backlight tubes on all VersaView displays Half brightness for integrated display computers and monitors average 50 000 hours As a result of these significant improvements backlights are no longer considered replaceable components INDUSTRIAL COMPUTING www ab com versaview www rockwellautomation com Power Control and Information Solutions Headquarters Americas Rockwell Automation 1201 South Second Street Milwaukee WI 53204 2496 USA Tel 1 414 382 2000 Fax 1 414 382 4444 Europe Middle East Africa Rockwell Automation Vorstlaan Boulevard du Souverain 36 1170 Brussels Belgium Tel 32 2 663 0600 Fax 32 2 663 0640 Asia Pacific Rockwell Automation Level 14 Core F Cyberport 3 100 Cyberport Road Hong Kong Tel 852 2887 4788 Fax 852 2508 184
13. ere is a preventative maintenance plan that includes a periodic cleaning of the fan filters If your environment demands that the computer operate in conditions near 50 C a better option for your storage device may be a solid state drive SSD These drives are much more robust for long term elevated temperature conditions gt Troubleshooting INDUSTRIAL COMPUTING www ab com versaview Installation APPLICATIO 6181P 6155R 6181F 6180W 6155R 6186M With all computers the possibility exists that you may experience an unexpected system shutdown e g lock up blue screen To reduce downtime during these events use the VersaView cloning utility The VersaView cloning utility provides advanced backup data protection and recovery to help you restore your system s efficiency The VersaView cloning utility uses the Symantec Ghost cloning program to create a duplicate image of the computer s hard drive Unlike standard recovery utilities that are able only to restore systems to original factory settings the Versa View cloning utility helps ensure that the most recent critical settings are protected during unplanned computer outages The duplicate image can be stored either on an unused portion of the hard drive or on external devices like CDs DVDs USB devices and networks For best results you should back up all your systems and data with the VersaView cloning utility
14. examine the installation to identify and correct the source of the problem Ensure that the branch circuit capacity is sufficient to carry the rated current of connected loads Attempt to identify the source s of transient energy by connecting and disconnecting individual loads while monitoring the line Loads generating high levels of transient energy should be moved to another branch or feeder circuit Sometimes excessive power line disturbances indicate a partial short circuit or other equipment defect Disturbances such as these may be a sign of imminent equipment failure Any defective equipment should be replaced In extreme cases an uninterruptible power supply UPS is an effective means for improving the consistency of the power supplied to the computer Noisy power Your VersaView computers power supply is properly isolated in compliance with immunity standard EN55024 ensuring fast transients or any electrical noise introduced from the power source does not adversely affect the computer s performance However if the power line is extremely noisy to the point where the noise level is above rated standards this noise may impact the computer negatively An uninterruptible power supply UPS can act as a power line conditioner to stop noisy power from affecting your computer s performance oooooooe nononono Insufficient current If you encounter trouble with DC powered VersaView equipment check that the line supply is
15. hrough a 12 5 mm nozzle 2 5 3 0 m away UL50 s NEMA 4 65 gallons minute through a 1 0 nozzle 10 12 ft away gt Troubleshooting INDUSTRIAL COMPUTING www ab com versaview Troubleshooting HOME DIAGNOSTICS e If you encounter problems with your VersaView industrial computer use the VersaView diagnostic utility to help identify the root cause The VersaView diagnostic utility green CD is a tool to help you diagnose hardware problems within your VersaView industrial computer It will determine the cause of a malfunction through tests of computer components including the processor memory and hard drive When to run the utility If your VersaView computer is malfunctioning run the diagnostic utility to find the root cause An initial diagnosis can be done without disconnecting or moving the computer The examination can take as little as five minutes or as much as eight hours depending upon the problem After the diagnostic utility has run it can generate a report for analysis by a technical support representative expediting any necessary repair process How to find the utility The diagnostic utility and accompanying literature can be found on the green VersaView Support CD part number 77184 927 99 that ships with every new VersaView industrial computer Any customers without a copy of this CD may obtain the diagnostic utility by contacting Rockwell Automation Technical Support http www rockwellautomation
16. ines above but the temperature around your VersaView product remains high here are some ideas to help reduce the heat further 1 The cabinet may be too small for the amount of heat generated The size of a cabinet is the main determinant of how much heat can be dissipated the larger the surface area of a cabinet the lower the temperature rise inside To determine surface area of a cabinet consider all six sides however any surfaces not available to dissipate heat for example a cabinet surface mounted against a wall should not be included Surface area 2 a b a c b c 144 in square feet CONTINUED gt Troubleshooting INDUSTRIAL COMPUTING www ab com versaview Installation PE TEMPERATURE 6181P 6181F 6180W 6155R 6186M 2 Turn off your display when the computer system is not in use In the Control Panel gt Power Options setting change your Turn off monitor setting to after 20 minutes It takes just the touch of a key movement of the mouse or a press on the touchscreen to wake up the display To calculate heat dissipation consider the number of watts used by equipment housed in the cabinet To find the proper wattage of your VersaView product visit www ab com versaview or consult your owner s manual Once the total power in watts is determined divide the total watts by the area in square feet from the formula above The result is a watts square foot value that can be
17. ing INDUSTRIAL COMPUTING www ab com versaview Installation PE TEMPERATURE 6181P 6181F 6180W 6155R 6186M Although VersaView industrial computers and monitors can operate in temperatures up to 50 C their reliability and longevity will be lessened when they are exposed to ambient temperatures of 40 C or more for long periods of time To minimize the effects of high temperatures on your VersaView product please follow these guidelines 1 When installing a VersaView computer or monitor in a cabinet ensure that there is enough space around the product to provide adequate airflow The product s inlets and outlets must remain clear of obstructions Refer to figure 1 for a clearance requirement example a2 2 The ambient air within a properly sized enclosure must be kept within the product s stated limits 0 50 C It is FIGURE 1 important to note that other equipment nearby may generate heat that affects the computer or monitor To help reduce hotspots in the cabinet install circulating fans near the bottom of the cabinet to ssssssssss provide air movement 6180W 3 Since heat rises it is always best to house computers and monitors in the lower portion of your cabinet To better understand the temperature of your intended application thermal monitoring equipment should be used An example of thermal monitoring equipment can be found at www telatemp com 6155R If you have followed the guidel
18. l Support if you have any product questions or concerns gt Installation gt Troubleshooting Rockwell ALLEN BRADLEY ROCKWELL SOFTWARE DODGE RELIANCE ELECTRIC Automation Installation PE POWER Reliable computing performance is required in today s operationally lean environment Consistent clean power is a key deliverable to insuring your computer s performance Power sags noisy transients on the power line and improper power cycles will lead to event log errors potential re starts of the operating system and possibly the damaging of internal hardware components Make sure to review the power management suggestions during the installation of you computer solution TEMPERATURE Perhaps the most concealed threat to a computer s long term reliability is excessive exposure to high temperatures All electronics have some amount of de rating that begins to reduce their MTBF as the temperature rises Proper considerations should be made to reduce excessive exposure to temperature Most VersaView industrial computers are rated to 50 C Reducing the temperature even if your application is within our specified limit will increase long term reliability APPLICATION Each deployment of a computer is unique Most companies invest a significant amount of time in configuring and validating their computer s applications operating system environment and hardware interfaces Protect your investment All VersaView computer solutions
19. ndows operating system The VersaView diagnostic utility also will assist you if you ever need to call Rockwell Automation Technical Support Floppy drive cleaning kits Floppy disks are far less popular now than they were in the past With decreased floppy disk usage there is a greater chance of dust and dirt accumulating in the read write mechanism of the floppy drive To combat this use a 3 5 floppy disk drive cleaner to clean the drive Please note this is necessary only if you experience problems with the drive HOME CD DVD cleaning kits If you experience problems with your CD or DVD drive you may try cleaning it with a CD or DVD cleaning kit which typically consists of a CD with several fine brushes to sweep dust off the laser Avoid kits that contain cleaning fluid since the fluid may leave a residue that creates more problems in the drive FANS AND FAN FILTERS Proper operation Perform periodic checks of your VersaView computer s cooling fans to ensure the fans are working clean and able to circulate air properly The chance of fan failure increases when dust contamination or other impediments to air movement are present Proper fan operation is critical to your computer s performance if the CPU is not kept within its specified temperature abnormal operation may result If the VersaView computer resides in an enclosure check any other fans meant to cool the computer within the enclosure Fan filter cleaning and r
20. re maintenance To keep your VersaView industrial computer running properly you should follow these maintenance recommendations Please note that every computer installation is different In general the more severe the operating temperature vibration shock contamination etc the more regular preventive maintenance is required Each computer owner must determine the appropriate amount of preventive maintenance taking into account the ramifications that would result from his or her computer being rendered inoperable due to lack of proper maintenance The information provided below is a generalized list of maintenance recommendations for VersaView industrial computers HARD DRIVES AND SOLID STATE DRIVES Create backup images of your hard drive Software corruption is one of the most common problems in hard drives If your system uses a rotating media hard disk drive that drive is one of the weakest hardware components in the system Always create a backup image of your hard drive in case the hard drive fails or the system cannot recover To create a backup of your VersaView industrial computer use the VersaView cloning utility The cloning utility and instructions can be found on the red Utility Accessory CD part number A77184 925 99 that shipped with your computer Duplicate instructions are available at http literature rockwellautomation com There are two critical images you should clone to removable media 1 Rockwell
21. rning the computer off allows your Windows operating system to do a clean up Restarting Windows often fixes small errors within the operating system or your applications Second you will allow the rotating media hard drive to rest Even when the hard drive is not being used by the running application Windows services almost continually make requests of the hard drive Reducing the on time of your hard drive will increase its life span Drive diagnostics If you experience any problems with your computer s hard disk drives your VersaView computer can help you figure out what is wrong All VersaView industrial computers ship with a green System Support CD part number 77184 927 99 This bootable CD contains a diagnostic program able to find problems on your overall system without booting up into the Windows operating system The VersaView diagnostic Utility also will assist you if you ever need to call Rockwell Automation Technical Support Hard disk drive replacement Rotating media hard disk drives are considered replaceable components As part of your preventive maintenance strategy you must determine when your hard disk drive should be replaced Applications that require the computer to run continually or in environments of high temperature shock or vibration will wear out your hard disk drive more quickly than standard applications Rockwell Automation offers replacement hard disk drives and instructions on how to change your
22. tracked on a temperature rise graph figure 2 This graph estimates the temperature rise in the cabinet Weis raed above the ambient temperature outside the cabinet Please note that the graph in figure 2 applies to cabinets that are FIGURE 2 properly gasketed made of painted steel and not vented Higher temperatures are expected in stainless steel and aluminum cabinets due to weaker radiant heat transfer In those cases the results from the graph in figure 2 should be multiplied by 1 5 Temperature Rise Above Ambient F o O 2 4 6 8 10 l2 l4 16 3 Ifthe operating environment allows it you should provide better ventilation of the cabinet through the following means e adding vents at the top and bottom of the cabinet to increase air flow making sure that vents to the surrounding environment are filtered to prevent dust and airborne debris from entering the cabinet mounting fans externally taking care not to increase vibration e air conditioning in cases where ventilation and fan circulation do not bring the cabinet temperature within the operating specification There are sources for additional information relative to heat dissipation One example 6155R is www hoffmanonline com technical_info 4 If your application allows your computer to be shutdown take the opportunity to do a controlled shutdown Periodic shutdown will help extend the life of your computer 5 If your computer has fan filters make sure th
23. ugh to provide adequate heat dissipation Satisfying the minimum clearances does not mean that the enclosure is properly sized The minimum clearances represent the minimum space required to allow proper air flow However the internal ambient temperature must not exceed the product s specified limit e Follow the required mounting clip torque specifications provided in the installation instructions Over torquing the clips may compress the gasket too far possibly jeopardizing the watertight seal Additional following the proper sequencing for torquing the mounting clips Torquing the clips in a circular fashion may result in breach of the watertight seal e When using computers or monitors on doors or pendant arms make sure to take into consideration the amplitude of the shock or vibration that could be introduced to the computer during both operating and non operating conditions Attempt to mount the computer to enclosures that are fixed to the floor whenever possible e Dampen or eliminate vibration from fans and cooling units whenever possible The VersaView panelmount computers and monitors meet either an IP65 or IP66 watertight standard and the UL50 NEMA4 watertight standard If your application requires the computer to be hosed down make sure the water pressure s volume and location do not exceed the specified limits 6155R IP65 12 5 liters minute through a 6 3 mm nozzle 2 5 3 0 m away IP66 100 liters minute t
24. ully consider your application s effect on the hard drive There several ways to configure your computer to extend the life of your hard disk 1 Configure your computer to turn off your hard disk after a period of inactivity 20 minutes typical This setting is found in the Microsoft Windows Control Panel under Power Options 2 Increase the amount of RAM in the system and lower the virtual memory setting which will result in fewer hard disk writes The virtual memory options can be found in Control Panel gt System Properties gt Performance Settings gt Advanced gt Troubleshooting INDUSTRIAL COMPUTING www ab com versaview Installation PE POWER N TEMPERATURE APPLICATION 6181P 6181F 6180W 6155R 6186M Computers are susceptible to shock and vibration as they are being shipped to their final destination Rockwell Automation has qualified the production packaging material to provide adequate protection during shipment If a computer is required to be transported after it has been configured the computer must be removed and placed back into the original packaging to ensure it is adequately protected Proper mounting of your VersaView industrial computer or monitor will eliminate potential problems and lengthen the product s life Please keep the following points in mind when deciding where to house your VersaView product e Ensure that the enclosure is large eno