Home

User`s Manual - MARUSON Technology

image

Contents

1. O Connect UPS to Utility Use the power cord that came with your UPS to connect the UPS directly to the wall outlet Do not power the UPS using a surge suppressor or power strip Q j ri ri Fe UPS SYSTEMS Power Pro ly Power Switch Press and release the button to supply power to the Battery Power Switch UPS Status Indicators AC Mode green lighting Battery Mode yellow flashing Fault red lighting A Fui Time Surge Protection Outlets 2 Connect a printer fax machine or scanner to the Full Time Surge Protected Outlets Both outlets do not provide power during power failure a Printer GS Scanner CAUTION DO NOT connect a printer to any Battery Power Supplied outlet Network Power Pro UPS protects a single line 1 in 1out phone modem or fax machine from surges when connected through the UPS Plug in conning Internet line into the IN socket Use one more Internet line cable in the
2. OUT socket and plug one other end to the modem input socket O Connect UPS to Computer Connect one end of the USB cable to PC and the other to the USB port at the rear of the UPS Insert ViewPower software CD or download the latest version of ViewPower software from http www power software download com to your hard drive Follow on screen instructions to complete the software installation Once PC is restarted ViewPower is geared and presents as an orange plug icon located in the system tray at the right bottom corner ViewPower configuration UPS setting Control View format Language Help aN wt t w User type Adminstrator es j Mortored UPS eric volt power loca B ide LEFFRAL RREN Status History 7 Turn On Off To turn on the UPS unit press the power On Off Switch once To turn off the UPS unit press the Power On Off Switch again p UPS SYSTEMS To store the UPS for an extended period cover it and store with battery fully charged While in storage recharge the battery every 3 months to secure battery life UPS Indicators and Controls AC Mode Indicator This green LED is lit when the UPS transfers utility power to both Battery Power Supplied Outlets and Full Time Surge Protection Outlets Supplied Outlets i Battery Mode Indicator This yellow LED flashes when the utility power is outside acceptable limits and the battery supp
3. 230 240VAC 81 145VAC or 162 290VAC 50 60Hz Auto Sensing lt Voltage INPUT IS j QO g ole 2 5 lt o gt oO Frequency Regulation OUTPUT 50Hz or 60Hz 1Hz Simulated sine wave Battery Type 12V7Ah x 2 ack up Time BATTERY Up to 40 minutes us Q ax O Q D Nr J D O 2 s O D a G AVERE 3 3 a D 3 8 Hours to 90 after complete discharge TRANSFER TIME 4 6ms Typical AC Surge Protection Phone fax DSL Network Surge Protection EMI RFI Filter AC Input Full Protection Overcharge and Overload Protection Dimension 350 x 146 x 160mm PHYSICAL DxWxH 13 8x5 7x6 3 in Net Weight 8 0kgs 21 16lbs Operating Environment ENVIRONMENT 0 40 C 0 90 Relative Humidity non condensing Noise Levei sLessthan45cB INTERFACE USB Windows 2000 2003 XP Vista 2008 Windows 7 Linux Unix and MAC Specification change without notice Full time 750 joules RJ11 RJ45 One In One Out PROTECTION Full time Circuit breaker Product Warranty and Service Information For U S customers please register your product at www MarusonUSA com For international customers please contact your local authorized distributor or e mail CustSrv MarusonUSA com for assistance MARUSON Maruson Technology Corporation 18557 E GALE AVE CITY OF INDUSTY CA 91748 see NO mMOlCa MO P O Box 1986 Walnut CA 91788 USA Toll Free 1 888 MARUSON TEL 1 626 912 8388 FAX 1 626 912 8680 E ma
4. POWER PRO 1100 ED Inspection The following items are inside the box UPS RJ11 Cable Software CD e User s Manual e e Power Cord e e USB Cable e Warranty Card Remove Power Pro UPS from its package and inspect it for damage If any damage is discovered re pack the unit and return it to the place of purchase 2 Place the UPS Provide 7 8 inch clearance on sides for adequate airflow around the unit when placing beside a monitor e Avoid direct sunlight e Avoid excessive heat e Avoid excessive humidity or liquids e Avoid excessive dust Equipment Protection Policy USER S MANUAL Battery Charging The UPS battery charges whenever the UPS is connected to utility power and typically requires less than eight hours to charge fully Operating runtime is reduced until the battery is fully charged 8 hours O Connecting Equipment to UPS Connect the equipment to Battery Power Supplied outlets Battery Power Supplied Outlets 6 Connect computer monitor and external drive to the Battery Power Supplied outlets These outlets provide battery backup EMI filtering line conditioning and surge protection Battery power is automatically provided in case of power failure Beware of the Power Switch it must be kept in the ON position otherwise the UPS will be disabled and your equipment will not be protected during a power failure
5. il Custsrv MarusonUSA com Web Site www MarusonUSA com
6. lies power only through the Battery Power vay Battery Mode sounding every 10 seconds 4 N Low Battery sounding every second Battery Replacement sounding every 2 seconds Fault Low Battery Battery Replacement Indicator This red LED is lit whenever the UPS fails low battery occurs or battery is close to the end of its useful life The battery should be Power Supplied Outlets Press and release the button again to switch off power to the Battery Power Supplied Outlets 7S Overload sounding every 0 5 second 4 replaced with UPS switched off Fault continuously sounding Connect Modem Phoneline POWER PRO 1100 Panel Information j USB Port 3 gt AC Input Circuit Breaker Network Modem Phone Line Surge Protection Aa 1 y CI ES Battery Power oH Full Time Surge Supplied Outlets i D Protection Outlets Safety Caution SAVE THESE INSTRUCTIONS This manual contains important instructions for models PRO 1100AVR that should be followed during installation and maintenance ofthe UPS and batteries This UPS utilizes voltage that may be hazardous Do not attempt to disassemble the unit The unit contains no user replaceable parts Only factory service personnel may perform repairs internal battery voltage is 12Vdc Sealed lead acid 6 cells batte
7. ry Connection to any other type of receptacle other than a two pole three wire grounded receptacle may result in shock hazard as well as violate local electrical codes Inthe event of an emergency press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS Do not allow any liquids or any foreign object to enter the UPS Do not place beverages or any other liquid containing vessels on or near the unit his unit is intended installation in a controlled environment temperature controlled indoor area free of conductive contaminants Avoid installing the UPS in locations where there is standing or running water or excessive humidity Do not plug the UPS input into its own output Do not attach a power strip or surge suppressor to the UPS Do not attach non computer related items such as medical equipment life support equipment microwave ovens or vacuum cleaners to UPS To reduce the risk of overheating the UPS do not cover the UPS cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heater or furnaces Unplug the UPS prior to cleaning and do not use liquid or spray detergent Do not open or mutilate the battery or batteries Release electrolyte is harmful to the skin and eyes It may be toxic A battery can presenta risk of electrical shock and high short circuit current The follo
8. tains non spillable sealed Lead Acid batteries On the battery you will the battery name Please refer to the chart below for recycling information or contact your local distributor for assistance Battery Name Recycling inside the USA Recycling outside the USA RITAR Battery 800 273 8599 Trouble Shooting Problem Possible Cause Solution No LED display Low battery on the front panel Charge battery up to 8 hours Battery fault Replace with the same type of battery Press the power switch again UPS is not turned on Alarm buzzer UPS is overloaded beeps continuously Verify that the load matches the UPS capability specified in the specs Overload of the UPS Battery voltage is too low Battery defect Remove some noncritical load failure backup ie ehon Charge battery 8 hours or more Replace with the same type of battery Comm unication Software is not installed properly Cable is not firmly connected Check the setting of the software Check the USB cable is firmly connected to the computer and confirm the setting again Mains normal Breaker trips but yellow LED brinks Reset the breaker Power cord is loose Reconnect the power cord properly If any abnormal situations occur that are not listed above please call for service immediately Specification CAPACITY PRO 1100AVR A W 1100VA 600 W 110 120VAC or 220
9. wing precautions should be observed when working on batteries 1 Remove watches rings or other metal objects from the hands 2 Use tools with insulated handles 3 Wear rubber gloves and boots 4 Do not lay tools or metal parts on top of batteries 5 Disconnect charging source prior to connecting or disconnecting batteries terminal Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from batteries When replacing batteries replace with the same number and type of sealed lead acid battery The maximum ambient temperature rating is 40 C During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3 5mA This pluggable type A equipment with battery already installed by the supplier is operator installable and may be operated by laymen Attention hazardous through electric shock Also with disconnection of this unit from the mains hazardous voltage still may be accessible through supply from battery The battery supply should be therefore disconnected in the plus and minus pole of the battery when maintenance or service work inside the UPS is necessary The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible USER S MANUAL Battery Recycling Information UPS con