Home
ACCU-SORT ® - trianglehi
Contents
1. YELLOW have been modified but have not been updated or saved Please scroll down to Update AXCESS Help AXCESS Configuration Save Retrieve Settings Diagnostics FAQ About AXCESS Code Label Code Type Min Length Max Length Filter Pattern Min Qty Max Qty I2of5 I20f5 10 10 Code 93 Code 93 10 Code 128 Code 128 24 Code 128 z Selected Code Type Code Label peksu TAs Min Length Min Quantity Max Length Max Quantity DETTE Specifications Connect Disconnect Header Help EA AXCESS Page Connect Disconnect AXCESS includes both Online and Offline modes You can switch between the two modes from the Connect Disconnect screen The individual fields shown on the Connect Disconnect screen are e Language This drop down list shows the available languages AXCESS screens will display in the selected language Future functionality e Connect Button Use AXCESS in the online mode The Online screen then displays the connected camera details e Work Offline Button Use AXCESS in the Offline mode Offline mode does not require Host IP address and Port fields IMPORTANT Use links on the AXCESS Menu Tree to navigate to other input screens DO NOT use the browser s Back button to navigate to previous screens Working Online In online mode user can connect to their Accu Vision MiniCam HandsFree Mid Range Camera System To connect online provide the IP address and port info
2. Bar Code Reader Camera Configuration Software ACCU SORT AXCESS for AccuVision User Interface for Mid Range Cameras ACESS ETT Symbologies Online Communications eenflauration 3 Save Retrieve Settings Met 1 Diagnostics is gt 4 Sca i Group Met 2 Help NN A Camera 31044 Top Controller Camera Groups Setup N t Camera 31167 Back Client Met 3 Restart Software Suite i Camera 31133 Front Client Shutdown Software Suite ae o gt Met 4 COM 1 COM 2 Note active Inactive Groups Match Codes Package Count Package Count Package Count Triqqer gt No ReadCount 1 No Read Count o No Read Cout p gge Last Package Data rest22__ Last Package Data Last Package Data Digital Outputs e3 Camera Type Camera Type Camera Type Camera Parameters Decoder Parameters IP 127 0 0 1 s i Camera 31044 Top x Type Controller Dia gnostic P aram eters i Connection Mode Online isionCapture AACESS Parameters f Provides quick and easy Overview e A Pian AXCESS for AccuVision Mid Range Cameras provides a familiar browser MiniCam HandsFree mid range based user interface that enables intuitive and fast configuration and modifi camera systems cation of the MiniCam HandsFree CCD camera systems eocereeceo rere eee eee eee eee eee eee ewe eee eee eee eee eee eens Developed with an intuitive user Get S
3. This feature rich user friendly combination of quick setup and at a glance diagnostics makes the AXCESS user interface the perfect compliment Image Captions TOP LEFT The AXCESS menu for your AccuVision camera solution tree provides easy access to configuration and diagnostics screens TOP RIGHT The AXCESS online screen shows the status of all connected cameras MIDDLE RIGHT AXCESS Save Retrieve Settings buttons allow for quick uploads and downloads of camera settings BOTTOM RIGHT Real time diagnostics view of image system status decoder messages and statistical counts vamera Statistics Total Package Count 5 Current Package ID S ACCU SORT SYSTEMS Lasers Cameras RFID Systems AXCESS for AccuVision User Interface Toolbar These buttons provide instant access to the save retrieve backup and restore functions Active Window Displays the next task as defined by AXCESS Wizard or any task selected from AXCESS Explorer Network Settings in this example Ce UUI i 0 CE ed After completing the configuration of an active window save the changes and proceed with the next step via either AXCESS Wizard or Explorer AXCESS AXCESS Configuration Ca mol Back Next Co Net 1 Communications 5 Format Framing Triggering ort Configuration Enable M Ethernet Labe
4. can be used to setup bar code groups on the Configurations gt Communications gt Groups screen NOTE Parameters shown in YELLOW have been modified but have not been updated or saved Connection Mode Offline dialed AXCESS Wizard e i First time users will find the wizard easy to use as it steps through the configuration process from start to finish Connection Mode Consistently identifies the camera IP address and connection mode online or offline during setup and diagnostics Selected Symbologies ss i i i lt CO Code Label Code Type Min Length Max Length Filter Pattern Min Qty Max Qty Cc I20f5 120f5 10 10 1 al BEJ code 129 coe aa Codes codes 00 aa Move Domm AXCESS helps you keep track of what s done Every step of the way you know which parameters you ve changed because they are highlighted in yellow until you UPDATE and SAVE islen Zoom In Ctrl A Ga mse fo torn ot ate i Diagnostics and Monitoring Tools like Image Viewer shown above enable you to assure optimum performance of your camera system Add Remove or Edit Bar Codes in seconds Use Bar Code Setup to include new bar codes to your list Or edit existing symbology parameters A Code Settings window make it a snap Getting Help is Easy AXCESS provides complete online help Simply access help at any time by 1 pressing the question mark button or 2 using the Help selection NOTE Parameters shown in
5. l IP Address e9 254 L1_ s0_ Port 2323 _ Connection Server Client Protocol TCP UDP Time Out sec Max Client Connections Persistent Connections M Receive Msg Symbologies AXCESS Explorer The navigation list allows users to quickly find the parameters they need to configure eoecerecec eee eee Match Codes Trigger Digital Outputs Camera Parameters Decoder Parameters Diagnostic Parameters isionCapture AXCESS Parameters Save Retrieve Settings or mod ify Diagnostics e Enable A checkmark indicates this communications port has been enabled i e Ethernet Label Assign a unique name to the Ethernet port configuration Help e IP Address Port Use to set the IP address and port number Use the Camera Groups Setup e Connection Select an option to configure the system as e a server or dlient e Protocol elect an option to use either TCP or UDP protocol d ia nostics Restart Software Suite e Time Out Assign communications time out in seconds o ERAEN Software Suite e Max Client Connections Sets the maximum number of client connections e Persistent Connections 4 checkmark indicates persistent connections have been enabled features during normal operations to confirm the camera system is functioning properly IMPORTANT When an application uses multiple controllers do not specify the same port number for more than one controller You must enable the NET communication port before it
6. rmation of the camera system Once connection is established with a camera system AXCESS will display the names and status each ra intha curtam fun ta hese Tha fnllawinn infarmnatinn For more information about auto ID and material handling solutions from Accu Sort Systems contact us at User Interface AXCESS for AccuVision Mid Range Cameras ACCU SORT SYSTEMS INC 511 School House Road Windows XP Embedded resident on MRC Decoder Internet Explorer 6 0 or greater Operating System Recommended Browsers Telford PA 18969 1 800 BAR CODE Bar Code Parameters Symbologies groups match codes padding stripping mod che cks Communications Parameters Controller Host Message format framing and filtering Other Parameters Trigger Transmit Camera Decoder Advanced info accusort com www accusort com Diagnostics Tools Compare Parameters Image Viewer Package History Logs Setup Decoder Host Camera AXCESS CD Content User s Manual and Quick Start Guide PDFs 2005 2008 Accu Sort Systems Inc All rights reserved ACCU SORT 1 800 BAR CODE AXCESS AccuVision and the AS logotype are trademarks or registered trademarks of Accu Sort Systems Inc Accu Sort reserves the right to change specifications without notice PN 1000062349 R11 CMS 08 0020 2008 07 23 LSM
7. tarted Quickly with Intuitive Setup Features interface that accommodates first time as well as advanced users eocereecer ere eee eee eee eee eee eee ewe eee eee eee eee ee eee ee Use AXCESS to configure AccuVision cameras without the need for onsite service Simply connect to your camera system remotely via a networked com Peicienily saves contiguration puter or locally using a keyboard monitor connected to the decoder parameters to both the camera and Specify valid 1D and 2D symbologies 2 decoder Define your communications message _ ee ee Ce ee Tre ee Pree format framing and filtering When EJ complete save your settings to the camera and you re ready to go Monitors all levels of camera system performance in real time eocereeceo reece eee eee eee eee eee eee ewe eee eee eee eee eee eee e IMPORTANT Do not attempt to change and save parameters while the system is running and packages are passing through the scanning area l Comprehensive Diagnostics Assure Peak Performance Operates remotely using a network connection or locally via keyboard SEUSAN sc uie e performance indicators and vital statistics are monitor connected to the decoder tein 7 provided through several screens including diagnostics setup tools and logs Compare parameters view images and package history using the diagnostics tools Useful message logs provide data on the decoder camera host and AXCESS
Download Pdf Manuals
Related Search
Related Contents
McAfee Platinum Enterprise Support Neuchâtel Parkinson Cowan Libra User's Manual PRESSURE WASHER QUICK TIPS - Graco RentalPro Equipment NEXT MCW - alarmas DISPOSABLE EQUIPMENT LIFE SCIENCE 医療・理化学用消耗品 Samsung HT-C350 Manuel de l'utilisateur Port Designs BAHIA Sleeve 10.1" Elac STARLET 5.1 Copyright © All rights reserved.
Failed to retrieve file