1. Touch one door Access Controller User manual V1 3 4 Installing wiring diagram JP1 JP2 1 Technical parameters PIN Color Function PIN Color Function 12V Red Power 12V Red Power NO ITEM Parameter GND Black Power GND Black Power 1 Operating voltage DC 12V 10 PUSH BLUE Low level output DATAO GREEN WG DATAO 2 Operating current lt 100mA OPEN Yellow Door Release DATA1 White WG DATA1 3 Dimensions 120mm x78mm x 22mm BELL Grey BELL NC Brown Relay NC output 4 Weight 1309 BELL White BELL COM BLUE Relay Com output 5 Ambient temperature 10 C 70 C NO PURPLE Relay NO output 6 Relative humidity 20 80 7 Storage 1000 users 8 Card type alternative EM ID card IC card for option 9 Card reading distance 1 15CM Release 2 Factory default settings Programming Password 123456 Open Mode Card or Access PIN Output signal time 5secs Backlight Auto Security function Off WG26Port Input 3 LED and buzzer indicates Two color LED red and green NO Led State Access control status 1 light red once every 1 sec Slow flash Holding state 2 light red N O Programming state 3 light green within Open time Unlocking state 4 light green once every 0 3sec Fast flash Pending further action Built in buzzer Description Status 1 short buzz Valid input 3 short buzz Invalid inp
2. d buzzer gives a short voice LED lights green Unlock signal outputs and door opens successfully Note If buzzer gives 3 short voices it indicates that the card or password is illegal and open failed 6 4 Change Access PIN Open mode card Access PIN After reading card and entering PIN to open the door within 5 seconds long press until the LED lights green with fast flash and then enter new Access PIN repeat new Access PIN buzzer gives a long voice Access PIN changed successfully
3. e If you added failed the buzzer gives 3 short voices Failure may be due to 1 User No duplicates 2 Card No already exists 3 store is full 4 key delete the users Press 4 0 0000 Delete all users Press 4 1 read card Delete card user via reading card Press 4 2 User No Delete card user via User No Press 4 3 input Card No Delete card user via input Card No Note Enter the left 10 digits of the card No 5 key modi fy Unlock Signal Output Time Press 5 XX Note XX is 2 digit 00 99 Unit second 00 indicates moment unlock 0 2 seconds 6 key set Open mode Press 6 10 Read valid card to open Press 6 11 Read valid card and enter Access PIN to open Press 6 12 Read valid card or enter Access PIN to open Press 6 13 As WG26 reader to use 7 key set Security mode Press 7 00 Turn off security function Press 7 01 Turn on security function System would be locked for 5 Minutes when continue to 1 read illegal card 10 times or 2 read the valid card but enter wrong Access PIN 4 times or 3 enter wrong Access PIN 10 times Press 7 02 Turn off Anti dismantle alarm function Press 7 03 Turn on Anti dismantle alarm function 8 k
4. ey set Anti dismantle set backlight mode and restore factory settings Press 8 01 Backlight Normally Open Press 8 02 Backlight Normally Close Press 8 03 Backlight Automate Backlight turn off in15 seconds if there are no operations Press 8 99 Restore Factory settings 5 3 Programming Password initialization method Step1 Turn off power and connect bin 2 amp 3 of S1 Step2 Turn on power and buzzer gives long voice Continuously Step3 Turn off power disconnect bin2 amp 3 and connect bin 1 amp 2 of S1 Step4 Turn on power again the buzzer gives a long voice Access controller initialization is completed After initializing Programming Password default settings 123456 user data will not be lost 6 User Open operation 6 1 Read card to open Open mode Card Card or Access PIN In holding state read valid card buzzer gives a short voice LED lights green Unlock signal outputs and door opens successfully 6 2 Enter Access PIN to open Open mode Card or Access PIN In holding state enter Access PIN buzzer gives a short voice LED lights green Unlock signal outputs and door opens successfully 6 3 Read card and enter Access PIN to open Open mode Card Access PIN In holding state read card buzzer gives a short voice LED lights green with fast flash then enter Access PIN within 5 seconds an
5. ut 1 long buzz Program success Continuous long buzz Restoring factory programming passwords 5 Access control function setting 5 1 Enter and exit programming mode Step1 In holding state press 123456 access controller enter system programming state with LED lighting red and buzzer giving a short voice Step2 In Programming state input programming commands See 5 2 Step3 In programming state press QJ to exit Note If there is no operation in 2mins system will exit programming state 5 2 Function setting O key modify the programming password Press 0 New password New password again Note programming password is 3 6 digits Default 123456 1 key Log on card users Press 1 User No read card User No is 4 digit 0001 9999 and use to delete users Bellow we refer to user No of 2 and 3 key are same Note Read card continuously for logging on users continuously and exit by pressing 2 key Log on password users Press 2 User No Access PIN Note Access PIN is 3 6 digits An access PIN also accounts for one user 3 key Log on card password users Press 3 User No read card Access PIN When you add a user each time you add a user successfully the buzzer gives a long voic