Home

User`s manual TwinLock compact

image

Contents

1. ssrr2 02020000202000000000000000000000000 29 6 1 REPROGRAMMING A MASTER CODE 30 6 2 REPROGRAMMING THE MANAGER CODE 31 6 3 PROGRAMMING AND REPROGRAMMING OF A USER Coppi 32 6 4 DELETE A USER CODE sissssscscecescsseiensoteccetsoesesegncd vdevsaesdaceceesdvsvevseeded nods sdeysoscecevssasnsedivesddeduetdcdunevesdsoswesgccteses 33 6 5 DISPLAY THE PROGRAMMED USER Coptps 34 6 6 SETTING THE DATE TIME AND WEEKDAY aenceeeessnsnsnnnnnssnsnnnnnnnnnnnnsnsnnnnnnnnnsnsnsnnnnonnnsnensnsnnnnnsnsnsssnsnnnnnnnnnnn 35 6 7 CODE LINKAGE PROGRAMMING FoUp Evp Conmpt ons 36 6 8 PROGRAM UNLOCKING TIME D LAN 37 6 9 PROGRAM OPENING DURESS FORCED SpOUEMCE nen 38 6 10 PROGRAM SILENT ALARM AS Nana ENER G RE aE RENS ENEE ENERE E IEE 39 6 11 PROGRAMMING ACTIVATION OF TWINXT LOCKUO 40 6 12 RESET THE INPUT BC RN 41 6 13 LOCK MOTOR SERVICE 43 6 14 REGISTER REPLACE LOCKS IN THE BNSTENM tetett etette tetest tE tEn Serer EEE EEEE EEEE Ee Eneee anene 44 6 15 WRITE LOG AND CONFIGURATION TO CHIP CARD 45 6 16 WRITE LOG AND CONFIGURATION TO CHIP CARD 46 6 17 READ NEW SYSTEM LANGUAGE nenn 47 6 18 IGNORE BOLT SYSTEM POSITION SWITCH aeesesesansnsnsnnnsnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 48 6 19 ACTIVATE PARALLEL CODE 49 6 20 AUTOMATIC LOCKING EEEE EE EEEE EEEE EEEE EEE EEE EE EEEE EE SEENE EEES E EEEE EEEE eessen 50 7 PROGRAMMING THE SYSTEM WITH THE PC SOFTWARE TWINCOMM
2. 15 09 08 Update user terminal and number of users I Subject to correction Support Hotline Carl Wittkopp GmbH amp Co KG Sternbergstr 5 D 42551 Velbert Tel 49 0 2051 9566 0 Fax 49 0 2051 9566 66 www cawi com INSYS Microelectronics GmbH Waffnergasse 8 D 93047 Regensburg Tel 49 0 941 58692 22 Fax 49 0 941 563471 www insys security de Version 1 06 62
3. close Select a lock lock 01 close Lock locks Please wait close lock closed 01 With the lock closed close the system cannot be re configured system locked Automatic return after 3 seconds Version 1 06 25 TwinLock compact WITTKOPP EINER d Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 5 3 Status Request of a Lock version request TwinLock compact Select the menu item Status Status into see menu plan 4 2 Status Info Tock closed ot The status of the selected component is displayed Version query SW version TS01 Lock With 2 locks in the system the version of the SWyersion 2 S01 second lock also is on display Automatic return after 3 seconds Version 1 06 26 TwinLock compact WITTKOPP EINER d Manual Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit 5 4 Responses Unlocking Messages open time lock week open time lock day open locking period open part blocking Open cancel Blocking time open terminal switch open manipulation Restart or currentless Status messages system check failure Bus A system check failure Bus B system check failure motor A system check failure motor B No unlocking possible because the current time is not within the time window defined in the weekly program
4. Data import Remove card The data import procedure is stored in the event log The new language is activated immediately after the card has been read Version 1 06 47 TwinLock compact WITTKQPP INSY Manual ee L sungen f r mehr Sicherheit MICROELECTRONICS 6 18 Ignore Bolt System Position Switch System Central inactive Central inactive Select Yes Yes No Central inactive Stored The setting is stored The bolt system position switch which may be connected to TwinAlarm or TwinXT is ignored for one locking procedure This means that the system can still be locked properly even if the switch is damaged Note In any case the customer service should be informed Version 1 06 TwinLock compact WITTKOPP EINER d Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 6 19 Activate Parallel Code Settings Parallel code Systemcode Enter system code Code x xx System code Please wait Evaluate the entry Parallel code Yes No Display of the current setting and selection of the new condition Parllel code Save setting Saved g Action completed Notes Only possible if there are 2 or 3 locks in the system Unlocking procedure During the unlocking procedure the status of lock 01 is queried first If lock 01 is closed an unlocking code must be entered wit
5. TwinLock compact WITTKOPP FINOS Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit TwinLock compact Manual Twin Lock S 4 D D EN 1300 VdS M 106302 M 106301 G 106016 G 106015 Class 2 C Version 1 06 1 TwinLock compact WITTKOPP UNN Hochsicherheitsschl sser EES Bese seseue Ne Manual L sungen f r mehr Sicherheit Copyright September 08 INSYS MICROELECTRONICS GmbH Any duplication of this manual is prohibited All rights on this documentation and the devices are with INSYS MICROELECTRONICS GmbH Regensburg Restrictions of guarantee This handbook contains a concise description The compilation of the text has been made with the utmost care Despite all efforts there may be deviations to the actual functions No guarantee can therefore be given for the accuracy of the contents We can neither assume legal responsibility nor any liability for incorrect information and their consequences Suggestions for improvements and comments are always welcome Trademarks and logos The use of a trademark or logo not shown below does not indicate that it is freely available for use INSYS is a registered trademark of INSYS MICROELECTRONICS GmbH Windows is a registered trademark of Microsoft Corporation Publisher INSYS MICROELECTRONICS GmbH Carl Wittkopp GmbH amp Co KG Waffnergasse 8 Sternbergstr 5 93047 Regensburg Germany 42551 Velbert
6. cccccssscsssssssersscessees 51 Tle GENERAL OPERATION 4 3448 nn a a een 52 7 2 PROGRAMMING OF GENERAL SETTINGS csccccsececsesssssseeececsesensecececccsesesseseeceeeseneeaeeeesesesesaseeeesesesesaaeeeeecs 54 7 3 PROGRAMMING THE UNLOCKING DELAY ccccccccccecsessscecececeesesececececsesessaeeeeecsenesseaeeececsesesaaeeeesesesenaaeeeeees 57 Version 1 06 4 TwinLock compact WITTKOPP EINER d Manual L sungen f r mehr Sicherheit FA DISPLAY EVENT E ee 58 7 3 USER DATA MANAGEMENT 93505 2205303 0 lt 5si04couzoucuedasssoguees E esas erregt aucdenssonded senda ES 59 7 6 CUSTOMER DATA MANAGEMENT est ege REES S beeceeas SEENEN ENEE EENS E N EE Ed 60 8 TECHNICAL DATA A chan tcscctessosaceavcvsecusnvecsceevcegsed sssbeccvantesccuessens cb enecbacesesens coasvosscnevsacvenceasesessuescnencenes 61 Revision History Support Hotline Version 1 06 TwinLock compact WITTKOPP UNN Hochsicherheitsschl sser H G eN Manual L sungen f r mehr Sicherheit 1 System Diagram TwinLock compact 1 lock with 12 VDC power supply TwinXT optional TwinConnect TwinXT RB B TwinLock TwinLock compact 2 locks with 12VDC power supply TwinXT optional TwinConnect ae TwinXT O Version 1 06 TwinLock compact WITTKOPP EINER d Hochsicherheitsschl sser
7. After TwinComm is started this card must be inserted into the chip card reader WITTKOPP EINER MICROELECTRONICS Information Solutions for higher security TwinLock ID i Bitte legen Sie die Lizenzkarte ein TwinCard Twincomm After the license chip card has been read the according locking system can be selected gt TwinLock compact Start screen Men assistent Info Zeitprog 1 Zeitprog 2 Einstellungen Schl sser bersicht Protokoll Men simulator Kundendat 4 MICROELECTRONICS L sungen f r mehr Sicherheit Before the chip card reader is used the serial interface to which the reader is connected must be activated The setting is done in the menu Chip card gt Configure Or the user is prompted to select the interface when the PC software starts for the first time Schnittstelle Schnittstelle SINAN Version 1 06 52 TwinLock compact WITTKOPP UNN Hochsicherheitsschl sser H Bese seseue Ne Manual L sungen f r mehr Sicherheit To read the data from the chip card TwinCard configuration it must be inserted into the chip card reader Then push the button Read chip card E TwinLock ID WITTK PP HECK MICROELECTRONICS Solutions for high To save the data to the chip card TwinCard configuration it must be inserted into the chip card reader Then push the button Write chip card TwinCard
8. Datei Chipkarte Sprache Tools Men assistent Info bersicht Protokoll Men simulator Kundendaten Benutzerdaten Benutzer bersicht The user overview can be printed or saved for Benutzer bersicht TwinLock administrative purposes Benutzer bersicht TwinLock Schloss 1 Mastercode Hr Direktor BenutzerCode 1 Hr Meier BenutzerCode 3 Fr Huber BenutzerCode 4 Fr M ller Schloss 2 Mastercode Version 1 06 59 TwinLock compact WITTKOPP EINER d MICROELECTRONICS Manual Hochsicherheitsschl sser L sungen f r mehr Sicherheit 7 6 Customer Data Management TwinComm Datei Chipkarte Sprache Tools Men assistent Info Zeitprog 1 Zeitprog 2 Einstellungen Schl sser bersicht Protokoll Men simulstor Kundendat 4 INSYS 3456789 Fa Mustermann AG 1930 Musterhausen Hr Mustermann Customer data can be saved and archived for each programming This means that an individual configuration file can be created for each customer This file can be read also at a later date Version 1 06 60 TwinLock compact Manual w rrkore INSE Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit 8 Technical Data Input Unit FlatControl Power supply Current consumption Dimensions Environment Protection class Schloss TwinLock compact Power supply Current consumption Dimensions Environment Protection class Bus
9. The latest 768 events programming processes hardware errors and certain status messages manipulation and sabotage attempts are logged in chronological order including date and time perhaps the user number There is also the possibility to transfer the entire event memory to the TwinCard configuration Display and printing of the event memory take place with the PC software TwinComm Configuration import export An entire configuration profile can be swapped out to the chip card Twin Card Configuration This profile can then be edited with the PC software TwinComm and reimported or saved The above described event log is also written to the card and can be displayed printed and saved using TwinComm System language The system language can be transferred using the chip card TwinCard language This card is available in several languages and must be requested separately More functions Reset of the individual system components Query of the system component version System components login logout Step by step operation for motor test Operation of several control units Version 1 06 16 TwinLock compact WITTKOPP UNN Hochsicherheitsschl sser H Bese aeseue Ne Manual L sungen f r mehr Sicherheit 3 4 Operational Safety Redundancy A dual bus system and a dual electronic and mechanical locking system in the locks guarantee high system stability The two identical system parts are completely independent from each
10. configuration Version 1 06 53 TwinLock compact Manual WITTKOPP INSE Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit 7 2 Programming of General Settings TwinComm Datei Chipkarte Sprache Tools Men assistent Info Einstellungen Schl sser bersicht Protokoll Mentisimulator Kundendaten Benutzerdaten en 4 gt vun e I msn SYS TwinLock zs CHIPDRIVE micro an COM1 Karte ist aktiviert und freigegeben Code linkage Activate TwinXT Parallel code Programming the four eye code principle For unlocking and programming 2 code entries each are required Lock I O The inputs and outputs of the extension unit TwinXT are activated and queried TwinXT must be activated for the function of automatic locking with door switch Only possible if there are 2 or 3 locks in the system Unlocking procedure During the unlocking procedure the status of lock 01 is queried first When lock 01 is closed an unlocking code must be entered without selecting lock 01 beforehand When lock 01 is open the condition of lock 02 is queried automatically When lock 02 is closed an unlocking code must be entered without selecting lock 02 beforehand Lock 02 unlocks Version 1 06 54 TwinLock compact Manual w rrkore INSE Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit Quick unlocking code Genera
11. Before the locking procedure the position of the bolt system is queried using a switch For this action the functions TwinXT active must be programmed not with TwinLock compact Activate silent alarm time delay 01 99 minutes not with TwinLock compact not with TwinLock compact The system line is displayed in the st line of the main menu on the display of the control unit It can be changed and set as required anytime Version 1 06 56 TwinLock compact WITTKOPP EINER Hochsicherheitsschl ss MICROELECTRONICS Manual L sungen f r mehr Sicherheit 7 3 Programming the Unlocking Delay TwinComm Datei Chipkarte Sprache Tools Men assistent Info Zeitprag 1 Zeitprog 2 Einstellungen Schl sser bersicht Protokoll Men simulator Kundendat lt gt WITTKOPP 5 ween EED For each lock an unlocking delay of 01 99 minutes can be programmed A release time of 01 15 minutes can be programmed as well during which a code entry must take place after the unlocking delay has expired Unlocking delay 00 No unlocking delay Release time 00 No code entry after unlocking delay The lock is immediately unlocked Version 1 06 57 TwinLock compact WITTKOPP EINER MICROELECTRONICS Manual Hochsicherheitsschl sser L sungen f r mehr Sicherheit 7 4 Display Event Log TwinComm Datei Chipkarte Sprache Tools Men assistent Info bersicht Protokoll Men sim
12. No unlocking possible because the current date coincides with the date of a defined special day No unlocking possible because the blocking time program is active No unlocking possible because the chosen lock is partly blocked An active timer program is cancelled by activating the input TIMEOUT in the secured area The control unit was switched or re initialized At the last code entry a user entered a wrong code more than three times Attention The system has either been restarted or the power supply has been interrupted Lock can no longer be addressed at bus A Please call customer service Lock can no longer be addressed at bus B Please call customer service Final bolt position of the lock at bus A is not accessible Please call customer service Final bolt position of the lock at bus B is not accessible Please call customer service lt D d o Q o 27 TwinLock compact WITTKOPP EINER d Manual Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit System check failure motor AB Status DMS XX Error General Error Messages invalid code invalid input failure BUS A failure BUS B failure motor AB COM Error Final bolt position of the lock is not accessible at bus A orbusB Please call customer service General lock fault Please call customer service Code entry incorrect Please enter correct code Incorr
13. distributor TwinConnect Power Supply Current consumption Dimensions Environment Protection class Extension Unit TwinXT Power Supply Current consumption Dimensions Environment Protection class 9 VDC Alternatively power supply unit 12 VDC via TwinConnect Alternatively emergency power supply via mini DC jack Stand by condition approx 30 uA Input condition display active approx 55mA 3 54 x 2 40 x 1 34 inches L x W x H 32 F 122 F 75 RH Environment class Il according to VdS IP 30 9VDC Idle state ca 40uA Motor operation without bolt load approx 110 mA 90x61x34mm LxBxH 0 50 C 75 r F Umweltklasse II nach VdS IP 30 12 VDC optional For power supply operation 12 VDC Approx 9 mA Only as distributor 0 mA 3 94 x 2 36 x 0 98 inches L x W x H 32 F 122 F 75 RH Environment class Il according to VdS IP 30 12 VDC optional Only for output relay operation For power supply operation 12 VDC Approx 20 mA Per relay Only when the inputs are used 0 mA 3 94 x 2 36 x 0 98 inches L x W x H 32 F 122 F 75 RH Environment class Il according to VdS IP 30 Version 1 06 61 TwinLock compact Manual WITTKOPP FINS hs lochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit Revision History 1 00 __ i Fiirstedition CMB Update 04 10 06 Update ES GH 30 10 06 update TwinCards Update 07 12 06 Update
14. gt gt Data export Remove card Select the menu item Import Export see menu plan 4 2 see above Enter system code Evaluate the entry Select data export wD i gt 0 with the menu keys Insert the TwinCard configuration TwinCard configuration clear el IT ente Select Export configuration Data is written to the chip card Remove card The data can be read by means of the Configuration set TwinComm and can be processed further The data export procedure is stored in the event log Version 1 06 46 TwinLock compact WITTKOPP EINER d Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 6 17 Read New System Language To switch the language of your system you need an according TwinCard language The language cards can be ordered on request TwinLock Select the menu item Import Export Import Export see menu plan 4 2 System code Enter system Code xxx code System code Evaluate the entry Please wait EE Da aport Select data import one Data import with the menu keys Insert the TwinCard language TwinLock ID TwinCard language Data import Insert card Select Export configuration Data import Language f a O W Or Data is read from the chip card into the system Read data gt gt gt gt gt gt Remove card
15. other and can therefore function individually Voltage monitoring When the power supply is applied or when the system recovers from energy saving mode the state of the battery system voltage is checked When the system falls below a set warning threshold an entry is made in the log and a message is displayed Press F2 to display the system voltage from the system menu TwinLock kxk TwinLock battery 9 0V III Low Batt Every time the system is restarted battery replacement or when the system is activated the battery voltage is measured and checked If the battery voltage falls below the set warning limit the message TI Low Batt is displayed and also stored in the event memory Version 1 06 17 TwinLock compact WITTKOPP EINER d Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit Power Failure The FlatControl receives its power supply via each of the two bus cables When a voltage failure occurs an emergency current feed for the entire system is possible via a jack at the bottom of the keyboard For this an adapter cable 7237 101 0 and a 9 volt block battery alkaline type is required For the connection of the adapter cable see figure Real time clock The date and the time are generated by a specially buffered real time clock and will survive even if the system receives no current for several days If a real time clock still happens to be deleted
16. time of the programmed normal time delay is used as release time The function Silent alarm can only be performed by the owner of the system code and is saved in the event log Example User code 1 2 3 4 5 6 gt gt alarm code 1 2 3 4 5 7 9 becomes 0 Version 1 06 39 TwinLock compact WITTKOPP UNN Hochsicherheitsschl sser H Bese aeseue Ne Manual L sungen f r mehr Sicherheit 6 11 Programming activation of TwinXT lock I O configuration Select the menu item Lock UO T ck 1 9 see menu plan 4 2 Systemcode Code x x Enter manager code Systemcode Evaluate the entry Please wait locj 1 0 Activate TwinXT yes No nn Activation of the function a Automatic locking via door switch lock I O saved Action completed Automatic return after 3 seconds Lock I O The inputs or outputs of the locks can be programmed by means of the system code The following functionality blocking element can be achieved Input functions Locking feature contact for external release blocking of the lock Locking after bolt contact query Output functions Silent alarm relay contact for silent alarm messages Display of the lock bolt position relay contact This programming action is saved in the event log Factory setting TwinXT inactive Release and bolt system contact high active Version 1 06 40 TwinLock compact WITTKOP
17. user is deleted usercode xx S Automatic return after 3 seconds Only the according owner of the master code can delete user codes This action is saved in the event log The function itself can only be performed at the control unit Version 1 06 33 TwinLock compact WITTKOPP EINER d Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 6 5 Display the Programmed User Codes Usercodes Select the menu item Display User Code Anzeige Usercode see menu plan 42 Usercodes Select the lock Schloss 01 Mastercodes Enter the master code of the Code selected lock Mastercodes Bitte warten Evaluate the entry Prog U Codes 03 Navigate through the user numbers RER OK Use the arrow keys lt gt Terminate with ENTER CLEAR Display the Programmed User Codes For each lock the users can be displayed which were entered in it This means that not the codes themselves are displayed but the status programmed not programmed The display of a programmed user code can only take place by entering the according master code of the lock Comment Prog U Codes 03 1 line Number of programmed user codes for this lock Usercode 01 OK e g progr u codes 03 Three user codes are programmed all in all 2 line Displays which user code is programmed OK programmed NOK not programmed e g ucode 01 O
18. Extension Unit TwinXT The TwinLock compact system can be extended by 2 inputs and 2 outputs by means of the extension unit TwinXT very easily Basically a TwinXT can be connected to each lock in the system Consequently each lock can be specifically locked or released and each lock can have a bolt system contact e pT Oss 2 switching inputs release bolt system contact for lock 1 2 switching inputs release bolt system contact for lock 2 2 relay outputs status silent alarm 30V 1A Power supply 12 VDC Antitamper loop with tamper switch Version 1 06 8 TwinLock compact Manual w rrkore INSE MICROELECTRONICS Hochsicherheitsschl sser L sungen f r mehr Sicherheit 2 5 Chip Cards TwinCard WITTKOPP UC ge MICROELECTRONICS Solutions for high TwinLock ID TwinCard code access WITTK PP HECK MICROELECTRONICS Solutions for high TwinLock ID TwinCard configuration WITTKOPP HR as MICROELECTRONICS Solutions for high TwinLock ID TwinCard language INSYS MICROELECTRONICS Solutions for high TwinLock ID TwinCard Twincomm TwinCard code access Chip card as physical code to disarm a BAS The code is changed continuously TwinCard configuration Chip card for the system configuration and the event log In cooperation the with PC software TwinComm the configuration can be imported or exported and the log can be re
19. Germany Phone 49 0 941 58692 22 Phone 49 0 2051 9566 0 Fax 49 0 941 563471 Fax 49 0 2051 9566 66 Internet http www insys security de Internet http www cawi com Subject to technical changes Errors excepted Date September 08 Version 1 06 Version 1 06 2 TwinLock compact WITTKOPP UNN Hochsicherheitsschl sser H Bese aeseue Ne Manual L sungen f r mehr Sicherheit The manual contains detailed information for the operation and the programming of the high safety lock TwinLock compact and is mainly intended for the system MASTER responsible for the system configuration and administration For users we recommend the Quick Reference Guide The concise document contains all important information required for normal system operation in short form The document ASSEMBLY INSTRUCTIONS has been created to assist with the installation of the system This contains all information for the implementation of the TwinLock system Version 1 06 3 TwinLock compact WITTKOPP EINER d MICROELECTRONICS Manual Hochsicherheitsschl sser L sungen f r mehr Sicherheit Table of contents Te SYSTEM DIAGRAM E 6 2 SYSTEM DESCRIPTION cissccsscccsiesscsussssscessssssscencesvessseoseccasveessesdesaccssesvesuesseateceveswsccvbecossdassousevebooveessosounsessarse 7 2 1 INPUT UNIT FLA TCONTROL EE 7 2 2 LOCK TWINLOCK COMPACT eege SERA SEENEN EE 7 2 3 BUS DISTRIB TOR 2 TWNCONNEC NEE H 2 A SE
20. K User code 01 is programmed Version 1 06 34 TwinLock compact WITTKOPP EINER d Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 6 6 Setting the Date Time and Weekday configuration Select the menu item Date Time date time see menu plan 4 2 System Code Enter system code Code xx x System code Please wait Evaluate the entry Select time date weekday Display current settings Activate the entry with enter Set the day of the week with menu keys time 10 01 Mo date 20 12 07 time 12 00 Mo Re enter date date 18 08 07 time or weekday date time saved Action completed Date Time The date time weekday can only be changed by the owner of the system code This action is saved in the event log Attention The correct setting of the date time weekday is the basis for all timer programs in the system or the event log to run properly Version 1 06 35 TwinLock compact WITTKOPP UNN Hochsicherheitsschl sser H Bese aeseue Ne Manual L sungen fur mehr Sicherheit 6 7 Code Linkage Programming Four Eye Code configuration Menu item Code Linkage code linkage select see menu plan 4 2 System code Enter system code Code System code Please wait Evaluation of the entry code linkage Select the moyeg taNo linkage ty
21. MICROELECTRONICS Manual L sungen f r mehr Sicherheit 2 System Description TwinLock compact is an electronic high safety lock system with integrated arming device for a burglary alarm system class 3 C It is a modular system The security relevant system parts are designed fully redundant The system consists of the following components Control units Terminals locks Bus distributor Connector for the individual components hub 1 1 1 1 Extension units TwinXT 2 1 Input Unit FlatControl The input unit is mounted on the outside of the safe see assembly of the input unit and is used to control and operate the locking system code input programming etc as well as to arm or disarm a burglary alarm system using a physical code chip card 2 2 Lock TwinLock compact The locks are mounted within the secured area of the safe see assembly of locks The mnemonic codes are stored and evaluated inside the locks 2 3 Bus Distributor TwinConnect The bus distributor TwinConnect enables the connection of the individual system components In addition TwinConnect has a power supply unit 12 VDC which can supply the TwinLock compact system When the arming device is connected however the system must be supplied through the BAS Version 1 06 7 TwinLock compact WITTKOPP EINER d Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 2 4
22. P UNN Hochsicherheitsschl sser H Bese aeseue Ne Manual L sungen f r mehr Sicherheit 6 12 Reset the Input Unit System Select the menu item System Reser eee see menu plan 4 2 System code Enter system code Code x x System code Evaluate the entry Please wait Reset Action completed saved Automatic return after 3 seconds System reset Only the owner of the manager code can perform the system reset The following settings are reset to factory defaults Unlocking delay Inactive System line TwinLock compact Battery warning limit 8 0V Code linkage 1 User Locks 0 Parallel code Inactive Forced Sequence Inactive Opening Duress Quick unlocking code user 09 Only the control unit is reset This means that all settings which are stored in the control unit are reset to factory defaults The locks are not reset during this procedure and therefore maintain their allocations Version 1 06 41 TwinLock compact WITTKOPP EINER d Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit After a control unit has been reset it is restarted The system sends a prompt for re registering System Setup New system To re integrate the existing locks into the system the menu item Terminal switch must be activated using the arrow keys S er a n Switch to Terminal switch rm n wi u F
23. The maximum blocking time is 15 minutes At the beginning of the locking period the incorrect code entries are classified as a manipulation attempt and stored in the event memory The next time that a correct code is entered the code error counter is reset and the locking period is deleted see also timer programs 3 2 2 sabotage safety 3 2 5 wrong code blocking time Version 1 06 14 TwinLock compact WITTKOPP EINER d Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 3 2 Timer Functions Time delay Unlocking delay individually configurable 00 99 min A release time 00 99 min can be programmed for each unlocking delay After the time delay expiration an unlocking code must be re entered The programming is performed by the system manager A user can be assigned a quick unlocking code function to bypass this program Alarm sabotage delays When the unlocking code was entered incorrectly 4 times a time delay of 1 minute starts For each further attempt with a wrong code the waiting period is extended by 1 minute up to a maximum of 15 minutes When a silent alarm is triggered a waiting period with a set duration will start These special programs can not be bypassed or interrupted Version 1 06 15 TwinLock compact WITTKOPP UNN Hochsicherheitsschl sser H Bese seseue Ne Manual L sungen f r mehr Sicherheit 3 3 Service Functions Event Log
24. XTENSION UNIT 3 WANDS KEE 8 2 3 CHP CARDS MINES dE SE SEENEN Ee 9 2 6 CONFIGURATION SET TWINCOMM est cd cc ss 505 00seeededuyeseve0sses sd sige ecsiectecssdeveecsedeeesvsedeocdensdeavjassdodeseasverssasseenes 10 32 FUNCTION DESCRIPTION EE ebe dE sve EENEG 11 3 1 CODE AND LOCKING FUNCTIONS cccccsssssscecececsessnsececececsessasececececsesssesecesecseneaueaesececseseaeaeseseesesesaaeeeeecs 12 3 2 TIMER ee Le EE 15 33 SERVICE Den Ri EE 16 34 OPERATIONAL SAFETY iiss scsecets cos ciate oneecevisesasebeceendevedenstsdeseesdessveavesdvsuvedsvocecedsisvounjosteesseaesudededetede ernennen 17 3 5 SABOTAGE SAFE TY E 19 3 6 PC SUPPORT WITH CONFIGURATION SET TWINCOMM ccccccccecesesecesecesecececesesececececeseseeeceseeesececeeeeeeeseeesess 19 4 CPERA TION E 20 4 1 DISPLAY AND CONTROL ELEMENTS OF THE INPUT EQUIPMENT eeeereeerreerreerreerreerrrsrreerreerreereesreeers 20 4 3 GENERAL OPERATING INSTRUCTION 22 5 GENERAL OPERATION PROCESSEG ccsssssssssssssssscscssccssssssensccecssssssscnecesecescsssececscesssssssssececeessessees 24 5 1 UNLOCKING A LOCK uo ccccecccecccececececececececececececececececececececececececececseeseceseceseceeseesseeceseseceseeeseeecesecececeeeeeeeseeesess 24 5 2 CtLosmGALock nn 25 5 3 STATUS REQUEST OF A LOCK VERSION REQUEST sssssssseieesesestittetest ttti tt tetett teknes etette Eeteen ere ee ansen eneren 26 5 4 RrspOoNsts nn 27 6 PROGRAMMING THE SYSTEM WITH THE CONTROL UNIT
25. ad out TwinCard language Chip card for the configuration of the system language German English Czech Portuguese TwinCard TwinComm Lizenzchipkarte for the TwinComm configuration Software Version 1 06 TwinLock compact WITTKOPP UNN Hochsicherheitsschl sser EE Bese sesene Ne Manual L sungen f r mehr Sicherheit 2 6 Configuration Set TwinComm The TwinLock compact system can be configured fast and conveniently using the program TwinComm in connection with the chip card reader of the configuration set and the chip card TwinCard configuration All settings and the event log can be displayed printed and saved TwinCard configuration Version 1 06 10 TwinLock compact WITTKOPP EINER d Hochsicherheitsschl sser MICROELECTRONICS Manual anua L sungen f r mehr Sicherheit 3 Function Description Code and Locking Functions 1 Master code per lock 1 System code 99 User codes per lock Status indicator for programmed user codes Code linking Four eye code Silent alarm Code manipulation detection Quick unlocking code Opening duress forced sequence Parallel code Automatic lock with door switch Timer Functions Time delay Alarm sabotage delays Automatic switching to daylight savings time Service Functions Event log 768 events Import export of the configuration via chip card System language can be configured using the chip card Reset of the individual system compo
26. ation lock 01 Select lock Mastercodes Enter the master code Code E Schlosses eingeben 000 OKOLO Mastercodes Please wait Evaluate the entry DQO ee Enter the new master code Of the selected lock S 2 Confirm Code Reconfirm the new master een Code once more gt S O New M Code Please wait Save the new code New M Code 3 Saved Action completed Automatic return after 3 seconds Besides the normal unlocking authorization the master code is also authorized to program the user codes When entering the code the user 00 is the master ACHTUNG The default code 123456 is pre programmed for the master of each lock For safety reasons the master codes of the individual locks must be changed immediately When programming the code make sure that the new unlocking code is checked repeatedly while the safe is open Do not use personal data when programming unlocking codes Loosing a master code can have very costly consequences Version 1 06 30 TwinLock compact Manual WITTKOPP EN Hochsicherheitsschl sser ca MICROELECTRONICS L sungen f r mehr Sicherheit 6 2 Reprogramming the Manager Code configuration Manager Code configuration lock 01 Manager code Code x xx Manager Code Please wait New Manager Code Code xx x Confirm Code Code kkkkkk New Manager Code Please wait New Manager Code S
27. aved Automatic return after 3 seconds Select the menu item Managercode see menu plan 4 2 Select the lock Enter the Manager Code of the Selectec lock Evaluate the entry Enter the new manager code of the selected lock Confirm new manager code again Save the new code Action completed The manager code does not have any opening authorization It does grant authorization to configure the system When the code is entered the user using this code is identified to be the system manager ACHTUNG The default code 111111 is pre programmed for the manager For safety reasons the master codes of the individual locks should be changed immediately Do not use personal data OOOO 0000 0000 OOOO OOO OOOO OOOO O OO COO The master code of lock 01 is also called the system code Version 1 06 31 TwinLock compact WITTKOPP EINER as Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 6 3 Programming and Reprogramming of a User Code The programming of the user codes is just possible if the locks are open configuration Select the menu item User Codes usercodes see menu plan 4 2 usercodes programming Select programming Usercodes lock 01 Select the lock old M U code user xx Enter the user n
28. ctivated or performed by the owner of the according master code of the according lock The user has 150 seconds to the next motor step If no key is pressed the function is cancelled The gradual opening or closing of the lock bolt is only meant for service purposes and can only be performed in an unlocked system state After this function is completed it is stored in the event log Version 1 06 43 TwinLock compact WITTKOPP EINER d Manual Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit 6 14 Register Replace Locks in the System Service Reg lock System code Code System code Please wait SReg lock New lock Bus cable on System code Code xx Serial number Please wait Reg lock Lock 02 OK Select the menu item Reg lock see menu plan 4 2 Enter system code Evaluate the entry Reg lock Selection Re register Replace lock Lock 01 Select the lock to be replaced Connect both bus cables of the according lock to TwinConnect and acknowledge with ENTER To allocate the serial number the system code of the new lock must be entered 111111 The serial number is transferred to the lock Detect and initialize the lock Acknowledge the lock number Automatic return after 3 seconds Re registering replacing of locks Only the owner of the system code can re register or replace a lock This action is stored in t
29. e secured area Log entry of all safety relevant events Blocking times when a wrong code is entered repeatedly see code programs timer programs Configuration only possibly for unlocked systems after entering the system codes 3 6 PC Support with Configuration Set TwinComm Basically the TwinLock compact system also works without PC support but using the software simplifies the configuration and enables easy reading of the event log The exchange of data with the lock system takes place with the chip card TwinCard configuration and the service function Import Export at the control unit Read out configuration profiles can be saved printed or modified and reimported All timer programs and system settings can be programmed When the system settings are read out the event log is also written to the chip card The protocol can be displayed and printed with TwinComm Version 1 06 19 TwinLock compact WITTKOPP EINER d MICROELECTRONICS Manual Hochsicherheitsschl sser L sungen f r mehr Sicherheit 4 Operation 4 1 Display and Control Elements of the Input Equipment LC Display Background lighting TWIN CONTROL eon DUSR UGY eg Menu keys Keypad Emergency power TwinLock ID TwinCard code access Insertion of the chip card Chip at the bottom Version 1 06 20 TwinLock compact TwinLock compact TwinLock compact Mo 15 09 08 11 15 TwinLoc
30. ect or invalid entry Check entry and retry Addressed component at bus A does not respond Please call customer service Addressed component at bus B does not respond Please call customer service Error when unlocking locking a lock Please call customer service Error during communication between control unit and lock Please call customer service Version 1 06 28 TwinLock compact WITTKOPP EINER d Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 6 Programming the System with the Control Unit The following functions and settings can be performed using the control unit Reprogram master code Reprogram manager code Program user codes Delete a user code Display a programmed User code Activate deactivate code linkage Date Time Program unlocking delay Program silent alarm Program parallel code Activate lock I O TwinXT Write configuration and log to chip card Read configuration from chip card Import new system language Automatic locking with door switch Some of these functions and all others can be implemented by means of the Configuration Set TwinComm Version 1 06 29 TwinLock compact WITTKOPP UNN Hochsicherheitsschl sser EES Bese seseue Ne Manual L sungen f r mehr Sicherheit 6 1 Reprogramming a Master Code configuration Select the menu item Master Code see menu plan 4 2 configur
31. ersion 1 06 23 TwinLock compact WITTKOPP UNN Hochsicherheitsschl sser EES Bese seseue Ne Manual L sungen f r mehr Sicherheit 5 General Operation Processes 5 1 Unlocking a Lock TwinLock compact open Select the menu item Unlock see menu plan 4 2 open Select the lock lock 01 code entry user no 02 lt Select the user number Code entry code Enter the unlock code The entry consists of 6 numbers bk code entry 42 Enter a further user no 05 lt Unlock code when The 4 eye code is activated Code entry code OOOO 0000 0000 OOOO OOOO COO OOL DOO COO open When time delay is activated delay XXminXXsec Display of the L Confirming the selected lock lock 01 Code entry amp 1 After the time delay has expired user O25 the release time starts a Within this time window code kx kx a further unlocking code must be entered open please wait After the system lock has been unlocked open the system may be configured lock open 01 open system unlocked Automatic return after 3 seconds Version 1 06 24 TwinLock compact WITTKOPP UNN Hochsicherheitsschl sser H Bese aeseue Ne Manual L sungen f r mehr Sicherheit 5 2 Closing a Lock tt compact Select the menu item Close close see menu plan 4 2
32. g codes apply to 2 locks e g the user does no longer need to select a lock and he is not bound to a specific lock In all locks however the same codes must be programmed for the according users e g User 08 Lock 1 Code 080808 Lock 2 Code 080808 User 009 Lock 1 Code 090909 Lock 2 Code 090909 Note on code linkage and parallel code Attention The code linkage and the parallel code can not be set simultaneously Silent alarm During a threatening situation a special alarm code may be entered when locks are opened and closed to trigger a silent alarm The alarm code consists of the normal user access code where the last number is increased by 1 9 switches to 0 The system now acts exactly like for the normal opening procedure for the user and the intimidator but at the same time a silent alarm signal is sent to the BAS Furthermore an individual opening time delay may be defined for the case of an alarm The lock can only be opened after the set waiting period has expired see also timer programs 3 2 2 The defined release time of the normal time delay is used as release time Example Unlocking code 1 2 3 4 5 6 gt gt Alarm code 1 2 3 4 5 7 Code Manipulation When the code has been entered incorrectly for four times a blocking time of 1 minute is activated During this blocking time no opening procedure may be performed Each further incorrect code entry increases the blocking time by one minute
33. he time is entered in minutes 00 99 A time delay can be entered for each lock Release time The release time is used to safeguard the time delay If a release time was programmed e g gt 00 a correct unlocking code must be entered after the time delay has expired to finally open the lock The release time is set in minutes 00 99 and specifies the period during which the user can re enter the unlocking code after the time delay has expired If no release was programmed 00 the lock will open without re entering the code after the time delay has expired xo The programming of this function can only be performed by the owner of the system code and is saved in the event log Factory setting Time 00 Rel 00 deactivated Version 1 06 37 TwinLock compact WITTKOPP UNN Hochsicherheitsschl sser H Bese aeseue Ne Manual L sungen f r mehr Sicherheit 6 9 Program Opening Duress Forced Sequence configuration Select the menu item Opening duress Opening duress see menu diagram see above System code Enter system code Code x xx Systemcode Evaluate the entry Please wait Forced sequence Display of the current setting yes ZNo and definition of the new condition Forced sequence Action completed Saved Automatic return after 3 seconds Opening Duress Forced Sequence Programming the function Opening Duress determines the unlocking or
34. he event log A maximum of 2 locks can be registered Version 1 06 44 TwinLock compact Manual Hochsicherheitsschl sser WITTKG PP cawi MICROELECTRONICS L sungen f r mehr Sicherheit 6 15 Write Log and Configuration to Chip Card TwinLock compact Import Export Systemcode Code x xx x x System code Please wait Import Export Daten Export Data export Insert card Data export Configuration Write data gt gt gt gt gt gt Daten Export Remove card Select the menu item Import Export see menu plan 4 2 Enter System Code Evaluate the entry Select data export with the menu keys Insert the TwinCard configuration Select Export configuration Data is written to the chip card Remove card TwinCard configuration The data can be read by means of the Configuration set TwinComm and can be processed further The data export procedure is stored in the event log Version 1 06 45 TwinLock compact Manual WITTKOPP INSE Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit 6 16 Write Log and Configuration to Chip Card TwinLock Import Export System code Code kkKK System code Please wait Import Export Data Export Data export Insert card Data export Configuration Write data gt gt gt gt
35. hout selecting lock 01 beforehand If lock 01 is open the condition of lock 02 is automatically queried When lock 02 is closed an unlocking code must be entered without selecting lock 02 beforehand Lock 02 unlocks gt Programming of the codes In all locks the same codes must be programmed for the according users e g User 08 Code Lock 1 080808 Code Lock 2 080808 Notes 1 For this functionality the explicit four eye code code linkage is deactivated 2 This function is only approved for 2 lock operation Version 1 06 49 TwinLock compact WITTKOPP EINER d Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 6 20 Automatic Locking The TwinLock system can be automatically locked using a door switch or a bolt system position switch The switch is connected to a TwinXT or TwinAlarm system depending on the system variant In idle state display off the door or bolt system switch is queried periodically Pressing the key will automatically lock the system Connection to TwinXT The following connections and settings must be performed Connect the switch at the terminals of the bolt system position switch see assembly instructions For a two lock system the terminals of the bolt system position switch must be bridged for lock 1 and 2 Activate TwinXT via the menu or the PC software Set the forced sequence via the menu or the PC software TwinComm Set
36. k compact 90 uolsioN TwinLock compact configuration TwinLock compact service TEE GER ion code linkage display Usercodes time delay ion UL ion opening duress ion alarm ion parallel code L ion lock UO ion system date time Reset ion service mastercodes motor service Yy ion service ercode install new lock configurations service usercodes central siabled jenueyy 3j2edwoD y907JuimL TwinLock compact import export N nus cr PIA uol ddOMLLM mes Tf Z 0 X D S 0 J D m Le m 0 4 7 D Z fal i WeuySsysIS ay uns ueBunsoeq TwinLock compact WITTKOPP EINER d Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 4 3 General Operating Instructions System Activation When idle the TwinLock System is activated by operating a menu key at the control unit After the activation a system check is performed and the individual states of the connected locks and of the TwinLock system are displayed system check system check lock opened 01 system locked Key Functions Menu Keys cear E gt ente Key Pad gt Menu navigation to the right i e next menu item lt Menu navigation to the left i e previous menu item enter Selection or confirmation clear Cancel return to previou
37. l Forced sequence Opening Duress Battery warning limit Switching to Daylight savings time Automatic locking a door switch Programming of the codes In all locks the same codes must be programmed for the according users e g user 08 Code lock 1 080808 Code lock 2 080808 Notes 1 For this functionality the explicit four eye code code linkage is deactivated 2 This function is only approved for 2 locks operation A user code that skips the unlocking delay can be defined as quick unlocking code not with TwinLock compact except for forced sequence programmable i e the unlocking and locking sequence Unlocking Lock 01 gt Lock 02 Locking Lock 02 gt Lock 01 With this function the threshold of the battery warning can be set between 6 8 V and 9 3 V Critical dropping of the supply voltage is automatically detected and the following message is displayed TwinLock Low Batt The time is automatically switched at the last weekend in March and at the last weekend in October Automatic locking with bolt system or door switch For this action the function TwinXT active must be programmed Version 1 06 55 TwinLock compact Manual WITTKOPP EN Hochsicherheitsschl sser H Bese aeseue Ne L sungen f r mehr Sicherheit Manual locking after bolt system query TwinAlarm active Silent alarm BAS level Arming with code card System line
38. locking sequence The system is in unlocked state only when all locks are open It will be in a locked state if all locks are closed Opening sequence lock 1 lock 2 system unblocked Locking sequence lock 2 lock 1 system locked The programming of this function can only be performed by the owner of the system code and is saved in the event log Factory setting No opening duress no forced sequence No Note This function is only possible with a 2 lock system Version 1 06 38 TwinLock compact WITTKOPP UNN Hochsicherheitsschl sser H G eN Manual L sungen f r mehr Sicherheit 6 10 Program silent alarm configuration Select the menu item Silent alarm Ge see menu plan 4 2 System Code Enter system code Code xxx System Code Please wait Evaluate the entry Silent alarm Display of the current setting ZER Te and selection of the new condition Silent alarm Enter the unlocking delay time Alarm delay 00 Silent alarm Silent alarm Action completed Saved Deleted Automatic return after 3 seconds Silent alarm A silent alarm is indicated via the alarm output of the arming device relay output When the function is activated a silent alarm is triggered by entering a valid unlocking code last code digit 1 see example and stored in the event log A time delay can be set 00 99 min which is only activated during the triggering of an alarm The defined release
39. nents Query of the system component version System components login logout Step by step operation for motor test System line free configurable System status indicator Voltage monitoring Version 1 06 11 TwinLock compact WITTKOPP EINER d Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 3 1 Code and Locking Functions Master code Each lock has a master code ID 00 6 digit master code The master code has the authorization to program lock specific procedures e g time delay user codes etc or to unlock respectively The master code can not be deleted or deactivated Attention The default code for the user 00 Master of each lock is the pre programmed code 123456 The user codes no 01 99 of the individual locks have been deactivated by the manufacturer For safety reasons the master codes of the individual codes must be changed IMMEDIATELY When programming the code you must see to the new unlocking code being checked repeatedly while the safe is open Do not use personal data when programming unlocking codes Loosing a master code can have very costly consequences Manager code There is one manager code 6 character code per lock The manager code is also called the system code The manager code has the authorization to program the settings and time functions It does not have any opening authorization though The manager code cannot be deleted or deacti
40. nlocking is tied to at least one code entry This always takes place via the menu keys see sabotage safety Unlocking can be prevented by several functions timer programs Opening duress forced sequence When a opening duress is activated the locks can only be opened in a certain order sequence lock 01 02 When locking the system the sequence is reversed The system is only unlocked and accessible for configuration and service after all locks have been opened Automatic lock with door switch The system can be locked automatically using a door switch or a bolt system contact which is either connected to a TwinAlarm or TwinXT system depending on the system variant This function can only be configured via the PC software TwinComm Code linkage For the entire system the function Four eye code can be programmed A lock can thus only be unlocked by entering 2 user codes respectively Programming can only be performed by the system master If a four eye code has already been programmed the system master can perform the programming only in connection with other users of lock 01 Version 1 06 13 TwinLock compact WITTKOPP EINER d Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit Parallel code Fora2 lock system the function parallel code can be programmed This function can only be configured via the PC software TwinComm In this case the unlockin
41. pe code linkage code linkage 1 User 2 User Automatic return after 3 seconds Code linkage When code linkage was selected four eye code the lock can only be unlocked or programmed by entering 2 codes The arrangement of the 2 codes is random The function applies to the entire system i e each lock must be unlocked with 2 codes when code linkage is activated The programming of this function can only be performed by the owner of the system code and is saved in the event log After the 4 eyes principle has been activated the system code also has to be entered in connection with a second code user code for programming Version 1 06 36 TwinLock compact WITTKOPP UNN Hochsicherheitsschl sser EES Bese seseue Ne Manual L sungen f r mehr Sicherheit 6 8 Program Unlocking Time Delay configuration Select the menu item Delay Delay see menu plan 4 2 Delay When several locks are available Lock 01 In the system select one lock Master code Code kkkxkkxk Enter the master code of the Selected lock Master code Please wait Evaluate the entry Master code Please wait _ Delay Display current settings kime 90 eee Start the entry with ENTER Delay Enter the new end time time 04 free 05 saved Deleted Automatic return after 3 seconds Time Delay for Unlocking This function delays the unlocking procedure when the code is entered correctly T
42. reuen Acknowledge with Enter Select the number of the control unit Acknowledge with Enter Usually always 01 System Setup Terminal No 01 lt System Setup Select the number of locks No DMS 01 lt available in the system Acknowledge with Enter Syst d A i GC To assign a serial number the system code of the lock or locks must be entered e g 1 1111 1 Serial number a a The serial number is transmitted to the lock Serial number A The serial number has been stored in the lock For the 2nd lock the master code of lock 2 has to be entered After all data is entered a system check is performed and the system is operational Version 1 06 42 TwinLock compact WITTKOPP UNN Hochsicherheitsschl sser H Bese aeseue Ne Manual L sungen f r mehr Sicherheit 6 13 Lock Motor Service Service Select the menu item Motor service Motor Service see menu plan 4 2 Motor service Select the lock Lock 01 Master code Enter the master code of the Code selected lock Master code Please wait Evaluate the entry Motor service Open and close gradually Span Closad gt Cancel with ENTER CLEAR Automatic return after 150 seconds Gradual opening and closing With this function the lock can be opened and closed gradually for service purposes This function can only be a
43. s menu item press 2 seconds return to system menu 0 9 Numeric keys to enter timer programs etc F2 Display of the current battery voltage only possible in the system menu Code input The code is only entered via the number keys The menu keys are intended for menu navigation and extended entries Using the menu keys for Entering the code using the numeric keypad Menu Navigation Version 1 06 22 TwinLock compact WITTKOPP EINER d Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit System Menu The start page of the menu structure is called system menu The system menu consists of one editable line e e S ane wig Mo 15 09 08 12 00 line 1 system line which can contain individual text and the current date time display line 2 Programming the Code Important notes regarding the programming of the code For security reasons switch the system code or the master code of the individual codes immediately after Installation The default code 12 3456 is pre programmed for the user no 00 system master and for the system master is 1 1 1 1 1 1 The user codes no 01 99 of the individual locks have been deactivated by the manufacturer When programming the code you must see to the new unlocking code being checked repeatedly while the safe is open S Do not use personal data when programming unlocking codes V
44. the system will be in an undefined state It must therefore be possible to set the date and time even when the system is locked Key F2 in the system menu gt gt system voltage gt gt key F2 gt gt 1 gt gt 0 gt gt date time system code required Further functions Protection against locking the locks while the bolt system is open only in connection with TwinXT or TwinAlarm Constant self diagnosis of the bus lines and system components Log entry of all warning and error messages Validity check of entered times and dates Version 1 06 18 TwinLock compact WITTKOPP EINER d Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 3 5 Sabotage safety Input unit TwinControl FlatControl The input unit in the unsecured area is secured by different measures Opening the case battery compartment TwinControl is immediately detected and displayed until an authorized user unlocks the system lock properly A person standing next to the authorized user cannot watch the entering of the code A special film in the view window of the terminal prevents the reading of the display from a lateral position Besides that the opening code is not entered via the keyboard but via the arrow keys above a digit selection on the display After each entry of a digit the cursor will be displayed at a randomly selected new position Further functions All codes are saved and evaluated within th
45. ting the switching status for the locking via PC software TwinComm Active low gt when the contact is closed gt System locks Active high gt when the contact is open gt System locks Setting Automatic locking with door switch via PC software TwinComm Optional Combination with partial blocking time via PC software TwinComm Version 1 06 50 TwinLock compact WITTKOPP EINER d Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 7 Programming the System with the PC Software TwinComm TwinLock ID TwinCard configuration The following functions can be performed with the configuration software TwinComm General settings e Silent alarm alarm delay TwinXT active Automatic switching to daylight savings time Quick unlocking code Four eye principle Parallel code Lock after bolt system contact query Automatic locking with door switch Quick unlocking code System line Battery warning limit Timer Programs e Alarm time delay e Time delay release time Managing functions e Customer data e User data e Menu simulator and menu wizard Version 1 06 51 TwinLock compact WITTKOPP EINER Hochsicher rheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 7 1 General Operation License chip card To active the PC software you will need a license chip card which is a part ofthe scope of delivery of the configuration set
46. ulator Kundendaten Benutzerdaten Benutzer bersicht af aioe Protokolldaten TwinComm Datum Aktion Status Zusatz 01 01 00 xx User 0 01 01 00 xx User 0 01 01 00 ES User 0 01 01 00 xx User 0 01 01 00 xxi User 0 01 01 00 xxi User 0 01 01 00 xxi User 0 01 01 00 xx User 0 01 01 00 xx User 0 01 01 00 xxi User 0 01 01 00 xx User 0 01 01 00 xx User 0 01 01 00 xx User 0 01 01 00 xx User 0 01 01 00 xx User 0 01 01 00 xx User 0 01 01 00 xx User 0 01 01 00 xx User 0 01 01 00 St User 0 01 01 00 xxi User 0 01 01 00 St User 0 CHIPDRIVE micro an COM1 Karte ist aktiviert und freigegeben The following events are logged All unlocking and locking procedures and all code entries are logged Furthermore all configuration procedures and manipulation attempts are logged The log list can be printed on a connected printer or saved and archived in a file Use the button Update user to display the according user names after the log is being read if the users were entered Version 1 06 58 TwinLock compact WITTKOPP EINER d Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 7 5 User Data Management TwinComm Datei Chipkarte Sprache Tools Men assistent Info bersicht Protokoll Men simulator Kundendaten Benutzerdaten Benutzer bersicht Each user of the lock can be allocated a name which is also saved in the event log TwinComm
47. umber old wie code Enter the old unlocking code code xx xx user codes or master code programming user no XX Enter the user number of the user code to be programmed OOOO 0000 0000 COOO OOOO O00 OOOO O OO OOO new usercodes code Enter the new unlocking code en Re enter the new unlocking code code usercodes please wait saved saved Automatic return after 3 seconds User codes A user can reprogram his her user code autonomously Otherwise the user only has an unlocking authorization When a user code is programmed for the first time the master code has to be entered first Attention When programming the code you must see to it that the new unlocking code is checked repeatedly while the safe is open Do not use personal data when programming a code Version 1 06 32 TwinLock compact WITTKOPP EINER d Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 6 4 Delete a user code usercodes F delete Select menu item Delete user codes see menu diagram 4 2 delete lock 01 Select lock Code entry Enter the user number 00 user no 00 for the master code amp S S OOO Ei Enter the master code of the selected lock O OOO OLORE delete Select the user user no XX 7 to be deleted OOO OOO Ei The selected
48. vated ATTENTION The code 1 1 1 11 1 is pre programmed as the works code for the system code User codes Benutzercodes Each lock has 35 user codes user ID 6 digit user code The user codes are programmed or deleted by the according master code A user can reprogram his her user code autonomously Otherwise the user only has an unlocking authorization A user code can be assigned the possibility for Quick unlocking quick unlocking code without time delay expiration see timer programs 3 2 2 Status indicator for programmed user codes For each lock the programmed user codes can be displayed The programming status i e OK or NOK is displayed The display can only be activated by the according lock master Version 1 06 12 TwinLock compact WITTKOPP UNN Hochsicherheitsschl sser H Bese aeseue Ne Manual L sungen f r mehr Sicherheit Quick opening code A user can be assigned the function of the quick opening code which circumvents a programmed time delay The user who has stored the code with number 09 has the quick opening code by default Code distribution in the TwinLock 7220 system lock 1 l 1 Systemcode i 1 Managercode mnemonic codes m 1 Mastercode 99 Usercodes lock 2 1 Managercode mnemonic codes 1 Mastercode 99 Usercodes secured area Unlocking amp Locking The u