Home

Series Six PLC Datasheets Manual, GEK-25367E

image

Contents

1. Switches Switches Limit Togele Proximity CamSwitches Relays Switches 115 VAC Input Module gt lea Kian Ai Dt A2 B2 C2 D2 B3 D3 A4 B4 C4 D4 A5 B5 5 DS 06 7 B7 C7 07 A8 B8 C8 D8 FRONT VIEW OF LED DISPLAY GFK 0174 a42381 1 LED PACKAGE CONTAINS LEDS AND ASSOCIATED CIRCUITRY 2 CIRCUIT BOARD CONNECTIONS MATE WITH USER LED ON THE ASSOCIATED INPUT IS IN THE ON STATE TERMINAL BLOCK LED OFF THE ASSOCIATED LED IS IN THE OFF STATE AN ON LED BACKLIGHTS THE GROUP DESIGNATION AND CIRCUIT NUMBER FOR EACH INPUT e g A1 THROUGH 8 THIS ALLOWS THE CIRCUIT NUMBERS TO BE READ DIRECTLY THROUGH THE FACEPLATE LENS 3 USER TERMINAL BLOCK ACCEPTS CONNECTIONS FROM USER INPUT DEVICES SEE THE INSTALLATION SECTION OF THIS DATA SHEET Figure 1 USER ITEMS 115 VAC Input Module GFK 0174 Installation The 115 VAC Input module can be installed in an I O rack or the I O rack section of the Series Six Plus Central Processor Unit CPU Follow these steps 1 Set the Dual In Line Package DIP switches directly behind the card slot on the rack back plane to establish the correct correspondence between the first group of 8 input terminals on this module and the first of four consecu tive groups of eight input number
2. FANUC Series Six Plus Programmable Controller GFK 0174 arch 1988 General Description The 115 VAC Input module detects bipolar AC volt age supplied by and controlled by the user The features and benefits of this module are summarized in Table 1 A module contains thirty two inputs divided into four groups A B C D each group sharing a neutral circuit A corn B corn C corn or D corn An input circuit contains an AC divider a noise filter to reduce common mode transients an opto isolator 115 VAC Input Module 32 Inputs per Module and a Schmitt trigger one shot which fires to indi cate that an AC voltage in a specified range has been detected An active input circuit is indicated by a Light Emitting Diode LED visible through a lens on the faceplate Refer to Table 2 for the 115 VAC Input module specifications Table 1 FEATURES AND BENEFITS 7 FEATURES High Density Input VAC 47 Hz 63 Hz Alpha numeric LED for each input on logic side Color coded faceplate Thirty two inputs per module in four isolated groups of eight Optically coupled inputs BENEFITS Useful in a variety of applications Allows visual inspection of I O operations Efficient use of rack space with flexibility in multiple common applications Provides electrical isolation between user power supplies and Series Six Plus Programmable Controller APPLICATIONS Monitor
3. ca Inc Charlottesville Virginia
4. p common to Series Six Plus common also between input groups when two more independent user power supplies are used for one module Continuous Transient Noise Immunity to Radiated Interference 115 VAC Input Module 4 2 SPECIFICATIONS 8 15 x 11 0 inches 208 x 280 mm 12 46 x 1 175 inches 317 x 30 mm 5 DC 104 ma maximum Thirty two 32 in four groups of 8 inputs 1 8 with independent common neutral connections 0 to 60 At the outside of rack 20 to 80 C 5 to 95 non condensing 80 132VAC 0 30VAC 98 ma 115 VAC 50 Hz 11 7 ma 115 VAC 60 Hz 10 20 ms 20 40 ms 240 VDC or 50 60 Hz AC 1 500 V_ peak non repetitive Showering arcs per NEMA ICS 2 230 40 Surges per ANSI C37 90 9 5W transmitter 27 450 MHz Complies with FCC Rule 15 for Class A computing devices Table 3 ORDERING INFORMATION DESCRIPTION Circuit Board and Faceplate Faceplate CATALOG NUMBER IC600BF832K IC600FP832K The equipment listed above having the catalog number shown is designed for listing by UL for use as an auxiliary control device The UL symbol on the nameplate means the product is listed by Underwriters Laboratories Inc UL Standard No Equipment 508 Industrial Control Equipment subsection Electronic Power Conversion For further information contact your local GE Fanuc North America Distributor or sales office GE Fanuc Automation North Ameri
5. s in the user program For further information on I O DIP switch settings refer to the Installation Section of the Series Six Plus Programmable Controller User s anual 96602 2 Use the extraction insertion tool furnished with the Series Six Plus CPU to insert or remove this module in the card slot 3 Guide the faceplate over the circuit board so that the terminals near the bottom of each are mated secure the faceplate to the rack using the thumbscrews at the top and bottom 4 Refer to Figure 2 Connect one side of the user circuit to the appropriate input terminal 1 through 8 Circuits connected to inputs 1 through 8 of a group must have their opposite sides connected to the common for that group Each input terminal can accommodate one No 12 AWG wire WARNING Voltages from user field devices may be pre sent on the faceplate terminals even if the power supply in the I O rack is off Care should be taken when handling the faceplate of this module or any wires connected to it a42382 INPUT MODULE AC SOURCE A B C ORD Figure 2 TYPICAL USER INPUT CONNEC TIONS Table Dimensions Circuit Board Faceplate Power Requirements Supplied by supply The user must supply power for the input devices Number of Inputs Operating Temperature Storage Temperature Humidity On Range Off Range Input Current Typical ON Delay OFF Delay Isolation any grou

Download Pdf Manuals

image

Related Search

Related Contents

CLOTHES DRYER  Guía Rápida Nuevo Modelo Gestión Sustituciones Personal Docente  Philips HPL 4 Pro User's Manual  Pyle Car Stereos User Manual  VGN-NW180J/S  Gebruiksaanwijzing 2 User manual 12 Notice d'utilisation 21  AG-WT10  User Manual  T'nB IPA5GR    

Copyright © All rights reserved.
Failed to retrieve file