Maintenance Bypass & Output Distribution Accessory
Contents
1. Liebert Keeping Business In Business POWER AVAILABILITY USER MANUAL Power Output Distribution 230 Volt S EMERSON Network Power TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS GLOSSARY OF SYMBOLS INTRODUCTION AND SYSTEM DESCRIPTION System Description INSTALLATION ON GXT 2U UPS RACK MOUNT INSTALLATION INDICATOR LAMPS MAINS Indicator Lamp UPS Indicator Lamp OPERATION Transfer to Maintenance Bypass Transfer to UPS SPECIFICATIONS TROUBLESHOOTING Figure 1 UPS mode of operation Figure 2 MAINS maintenance bypass mode Figure 3 2U POD connections Figure 4 Attaching POD securing brackets to rear of UPS Figure 5 Attaching POD to securing brackets Figure 6 2U POD with rack mounting brackets Figure 7 Indicator lamps on 2U POD IMPORTANT SAFETY INSTRUCTIONS N WARNING e DO NOT ATTEMPT TO SERVICE THIS PRODUCT YOURSELF OPENING OR REMOVING THE COVER MAY EXPOSE YOU TO DANGEROUS VOLTAGES EVEN WHEN THE AC CORD IS DISCONNECTED FROM THE ELECTRICAL SOCKET REFER ALL SERVICING TO QUALIFIED SERVICE PERSONNEL SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation and operation of the 2U POD This product is designed for commercial industrial use only with Liebert UPS systems It is not intended for use with life support and other designated critical devices Do not exceed POD or UPS rating labels Read all safety and o
2. d bypassing the UPS system see Figure 2 Mains power is supplied directly to the load through the 2U POD CAUTION Battery back up and conditioned power are NOT available during the MAINS mode of operation Figure 2 MAINS maintenance bypass mode gt Connected loads Mains The UPS may be turned off and removed without affecting the load See Figure 3 Figure 3 2U POD connections UPS INPUT Rotary switch MAINS INPUT Connect to load socket on and power Connect to mains wall socket Use rear of UPS Cable supplied indicator lamps original UPS mains input cord UPS MAINTENANCE BYPASS AVAILABLE AVAILABLE CIRCUIT BREAKER Lieben q z wins Connect UPS input cord here Connect loads Cable supplied Connect loads Figure 4 INSTALLATION ON GXT 2U UPS NOTE This manual provides instructions for the 2U POD only Refer to your UPS manual for UPS operation and installation instructions Unpack the 2U POD carefully noting the packing method Retain the box and packing material for possible future shipments Visually inspect the 2U POD for freight damage Report damage to the carrier and your local dealer or Liebert representative Verify that the 2U POD input cord UPS input cord and socket for the UPS are the same type of configuration If you already have a UPS installed turn off all connected loads and unplug them from the UPS Turn off the UPS and disconnect the input cord Attach the two POD securin
3. g brackets this is optional for GXT 2U UPS to the rear of the UPS see Figure 4 You will need a long M3 Phillips head screwdriver for this procedure the torque is 0 79 Nm or 7 in lb The POD brackets have a hole to allow the screwdriver to reach the screw Attaching POD securing brackets to rear of UPS 6 Next attach the POD to the securing brackets see Figure 5 The POD can be installed to Figure 5 face one of three different directions utilizing the same mounting procedures Attaching POD to securing brackets Make sure the 2U POD rotary switch is in the MAINS position Use the mains input cord originally used with the UPS Plug the mains input cord from the mains input socket to the mains wall socket WARNING The 2U POD is now electrically live The MAINS lamp orange should now be illuminated Using the cord provided connect the UPS input power socket to the POD socket labeled CONNECT UPS LINE CORD HERE WARNING The UPS system is now electrically live Using the cord provided connect the POD socket labeled UPS to one of the output sockets on the rear of the UPS Plug in all loads to the output distribution sockets evenly distributing them on the 2U POD The 2U POD now powers your equipment in the MAINS mode Turn ON the loads and ensure all are up and operating according to specification Start the UPS according to its specific user manual Verify that the UPS lamp green on the 2U POD
4. is illuminated If so transfer the rotary switch from MAINS to UPS The load is now being supplied with conditioned power through the UPS Before any operation or procedure always verify that both the UPS lamp green and the MAINS lamp orange are illuminated before changing the status of the rotary switch 5 Figure 6 RACK MOUNT INSTALLATION Rack mount installation of the 2U POD is possible with the use of the rack mounting brackets shipped with the POD See Figure 6 The rack mount brackets allow you to rack mount the POD in a 19 enclosure 23 to 19 rack adapters would have to purchased separately if you are using our 23 Foundation or equivalent cabinet The POD can be mounted to face one of four directions depending on your application and utilizing the rack mount brackets provided Determine the desired position and direction for the POD face it in that direction then attach the brackets to the POD with the screws provided Consult your rack enclosure manufacturer s recommendations for specific rack mounting hardware that will be required The holes on the rack mount bracket are notched for easy installation Tighten the POD securely to the rails and then follow the startup directions for the POD in the previous section Installation on GXT 2U UPS 2U POD with rack mounting brackets ups MAINTENANCE BYPASS AVAILABLE AVAILABLE N gt WW Liebert CIRCUIT BREAKER Hon vo Rack mounting bracket
5. n a single flexible package e Monitoring and control from systems of any size or location on site or remote Service and support through more than 100 service centers around the world and a 24 7 Customer Response Center While every precaution has been taken to ensure the accuracy and completeness of this literature Liebert Corporation assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions 2002 Liebert Corporation All rights reserved throughout the world Specifications subject to change without notice Liebert and the Liebert logo are registered trademarks of Liebert Corporation All names referred to are trademarks or registered trademarks of their respective owners SLI 23153 5 02 Technical Support United States 1050 Dearborn Drive P O Box 29186 Columbus OH 43229 Single Phase UPS 800 222 5877 Outside the United States 614 841 6755 3 Phase UPS 800 543 2378 Environmental Control 800 543 2778 Italy Via Leonardo Da Vinci 8 Zona Industriale Tognana 35028 Piove Di Sacco PD 39 049 9719 111 FAX 39 049 5841 257 Asia 23F Allied Kajima Bldg 138 Gloucester Road Wanchai Hong Kong 852 2 572 2201 FAX 852 2 831 0114 Web Site www liebert com E mail UPStech liebert com EMERSON
6. ons in the user manual for your UPS CAUTION For use in a controlled environment Refer to manual specifications for environmental conditions ZN WARNING lt WHEN THE 2U POD IS IN MAINS POSITION MAINTENANCE BYPASS MODE THE POWER TO THE CONNECTED LOAD IS NOT FILTERED OR CONDITIONED BY THE UPS THE LIEBERT UPS CONNECTED EQUIPMENT GUARANTEE IS NOT VALID WHILE IN THIS MODE OF OPERATION GLOSSARY OF SYMBOLS Indicates AC Input Indicates AC Output Consult the manual for additional information MAINS lamp indicates local power is available and the load may be transferred to bypass the UPS UPS lamp indicates UPS power is available and the load may be transferred to the UPS to provide computer grade power to the load INTRODUCTION AND SYSTEM DESCRIPTION Congratulations on your choice of the Liebert 2U POD The Liebert 2U POD provides main tenance bypass capability as well as power output distribution The Liebert 2U POD can be used on UPSs in the rack mount or tower configuration The Liebert 2U POD provides an isolated path of power for your UPS system for preventive maintenance or service System Description The 2U POD has two modes of operation UPS UPS available and MAINS maintenance bypass In UPS mode the power is routed through the UPS system delivering conditioned power to the load as shown in Figure 1 Figure 1 UPS mode of operation Connected Mains In MAINS mode the power is routed aroun
7. perating instructions before operating the 2U POD and the connected UPS system Adhere to all warnings on the unit and in this manual Follow all operating and user instructions Turn the UPS off and unplug the 2U POD before cleaning Use only a soft cloth never liquid or aerosol cleaners The UPS and 2U POD are designed for data processing equipment Do not plug laser print ers or appliances such as hair dryers heaters vacuum cleaners or electric drills into the UPS output sockets N WARNING DO NOT MODIFY THE CABLES IN ANY WAY THE POD SOCKETS SHOULD MATCH THE UPS SOCKETS CONSULT YOUR DEALER IF THE AC CORDS DO NOT MATCH THE MAINS SOCKET THE 2U POD MUST BE EARTHED AT ALL TIMES WHILE IN USE TURN OFF THE UPS BEFORE UNPLUGGING IT The UPS and the 2U POD are equipped with earthed plugs plug types vary depending on model Do not defeat the safety purpose of this plug If unable to fully insert the plug into the designated socket contact a qualified electrician or your local dealer or Liebert representative for assistance Route power supply cords so they are not walked on or pinched in anyway N CAUTION Risk of electric shock do not remove cover no user serviceable parts inside Refer servicing to qualified service personnel CAUTION This device receives power from multiple sources Before servicing this device remove all connections Before servicing the UPS follow Maintenance of UPS instructi
8. s INDICATOR LAMPS MAINS Indicator Lamp This orange lamp is illuminated when mains power is present see Figure 7 It signals that you may transfer the loads to maintenance bypass MAINS mode operation via the rotary switch During a mains power outage this lamp will be off and the UPS will supply battery back up power to the connected loads UPS Indicator Lamp This green lamp is illuminated when there is output power available from the UPS see Figure 7 It signals that it is safe to transfer the connected loads from mains power back to UPS output power Figure 7 Indicator lamps on 2U POD Green lamp Orange lamp Output power available from UPS MAINS power present Z UPS MAINTENANCE BYPASS AVAILABLE AVAILABLE CIRCUIT BREAKER 16A 250V T CONNECT UPS LINE CORD HERE E o Dair Rotary On OPERATION Transfer to Maintenance Bypass To transfer to maintenance bypass mains from UPS use the following steps 1 Ensure the MAINS lamp orange is illuminated If the lamp is not illuminated refer to Troubleshooting section 2 Transfer the rotary switch from UPS to MAINS provided the MAINS lamp is illuminated on the 2U POD 3 Turn the UPS off 4 Disconnect the two cables connecting the UPS to the 2U POD 5 You may now service the UPS Transfer to UPS To transfer to UPS from maintenance bypass mains use the following steps 1 Reconnect the UPS to the 2U POD Start the UPS according to
9. the instructions in the UPS user manual 2 Verify that UPS lamp green on the 2U POD is illuminated If so transfer the rotary bypass switch from MAINS to UPS If the lamp does not illuminate refer to Troubleshooting section Conditioned power is now being supplied through the UPS SPECIFICATIONS Transfer Time to and from maintenance bypass lt 6 milliseconds Operating Ambient Temperature 0 C to 40 C 32 F to 104 F Storage Ambient Temperature 20 C to 60 C 4 F to 140 F Dimensions W x D x H mm in 88 x 77 x 394 3 5 x 3 0 x 15 5 Weight kg Ibs 4 5 10 Humidity 0 to 95 non condensing Agency Standards CE EN 60950 ISTA Procedure 1A Electrical Rating See Model Label on MicroPOD This 2U POD is intended for use with a UPS meeting all the following requirements UPS input cord is compatible with the rating and type of socket on the 2U POD labeled CONNECT UPS LINE CORD HERE UPS output socket is compatible with the 2U POD input power connector labeled UPS Available mains socket is compatible with the 2U POD input power connector labeled MAINS The user must provide a suitable mains power cord with the appropriate country connector This will usually be the original UPS power cord which has been removed from the UPS mains input TROUBLESHOOTING Problem MAINS lamp orange not illuminated Cause Mains not present Sol
10. ution Call qualified service personnel to restore power to socket 2U POD input cord not connected to mains Refer to 2U POD installation instructions in this manual Installation on GXT 2U UPS and Rack Mount Installation UPS Available lamp green not illuminated UPS output power not present Turn on UPS Refer to UPS user manual UPS input and or output cord not connected to 2U POD Refer to 2U POD installation instructions in this manual Installation on GXT 2U UPS and Rack Mount Installation 2U POD will not start some all connected loads 2U POD output circuit breaker has tripped Reset 2U POD circuit protectors 2U POD circuit protectors trip after resetting Overcurrent on 2U POD socket Recalculate load requirements distribute load among other 2U POD sockets Liebert Keeping Business In Business POWER AVAILABILITY USER MANUAL The Company Behind the Products With over a million installations around the globe Liebert is the world leader in computer protection systems Since its founding in 1965 Liebert has developed a complete range of support and protection systems for sensitive electronics e Environmental systems close control air conditioning from 1 to 60 tons e Power conditioning and UPS with power ranges from 300 VA to more than 1000 kVA e Integrated systems that provide both environmental and power protection i
Download Pdf Manuals
Related Search
Related Contents
septembre 2009 CybOnLine Manual - Personal WWW Pages LOGASnet User Guide for DCLG Users v1.0 Samsung โทรศัพท์มือถือ Trendy GT-E1150 Patton electronic 1092ARC Network Card User Manual Manuale - EBARA Pumps Europe SpA hp LaserJet 1010/1012/1015 series printer user guide School Inspections Manual Manual de Instrução PDA オプション Copyright © All rights reserved.