Home
Digital Serial Analyzer Sampling Oscilloscope
Contents
1. Input Internal Clock See Trigger System specification A Output Options External 10 MHz 5 V maximum Option Description Reference Input i Opt GT Gated Trigger ay o 1 25 V maximum Opt JARB Jitter Analysis of Arbitrary Data included with purchase utpu of Opt JNB or Opt JNB01 See 80SJARB for more Rear Panel information USB Ports 4 USB 2 0 connectors Opt JNB Essential and Advanced Jitter Noise and BER Analysis Parallel Port IEEE 1284 DB 25 connector Opt JNBO1 Software See 80SJNB Essentials and 80SJNB Advanced for more information LAN Port RJ 45 connector supports 10BASE T 100BASE T Serial Port DB 9 COM1 port GPIB IEEE488 2 connector Service Options VGA Video Port DB 15 female connector connect a second monitor to use Option Description dual monitor display mode Opt C3 Calibration Service 3 Years Oscilloscope VGA DB 15 female connector connect to show the oscilloscope Opt C5 Calibration Service 5 Years Video Port display including live waveforms on an external monitor or acai projector Opt D1 Calibration Data Report Gated Trigger Input Option GT only See Trigger System specification Opt D3 Calibration Data Report 3 Years with Opt C3 Opt D5 Calibration Data Report 5 Years with Opt C5 Operating Requirements Opt R3 Repair Service 3 Years Characteristic Description Opt R5 Repair Service 5 Years Power Requirements Line voltage and 100 to 240 V AC 10 50 60
2. Module Typical TDR Rise Time at Full Bandwidth Bandwidth RMS Noise at Remote Sampler Incident 10 Reflected 10 Performance Bandwidth 11 80E10 12 ps 15 ps 50 GHz 40 GHz 50 GHz 600 uV Yes fully integrated and 30 GHz 40 GHz 370 uV 2 meter cable user selectable 30 GHz 300 uV 80E08 18 ps 20 ps 30 GHz 20 GHz user 30 GHz 300 uV Yes fully integrated selectable 20 GHz 280 uV 2 meter cable 80E04 23 ps 28 ps 20 GHz 600 pV No optional 80N01 10 Values shown are warranted unless printed in an italic typeface which represents a typical value 11 Calculated from 35 bandwidth rise time product 2 meter extender cable www tektronix com 9 Data Sheet Electrical Modules 80E09 80E07 80E06 80E03 and 80E01 The 80E09 and 80E07 are dual channel modules with remote samplers capable of noise as low as 450 uVrus at 60 GHz bandwidth and 300 uVrus Noise at 30 GHz bandwidth Each small form factor remote sampler is attached to a 2 meter cable to minimize the effects of cables probes and fixtures to ensure the best system fidelity User selectable bandwidth settings 60 40 30 on 80E09 and 30 20 on 80E07 offer optimal noise bandwidth trade off 80E06 and 80E01 are single channel 70 and 50 GHz bandwidth sampling modules respectively 80E06 provides the widest bandwidth and fastest rise time with world class system fidelity Both 80E06 and 80E01 provide a superior maximum operating range of 1 6 V Both modules can be used Electr
3. 10 dB nominal 20 dB nominal 26 dB nominal 10 20 30 40 50 Frequency GHz 80E10 Return Loss S11 Phase Uncertainty 12 dB nominal 20 dB nominal 26 dB nominal 10 20 30 40 50 Frequency GHz www tektronix com 23 Data Sheet Physical Characteristics for Electrical Sampling Modules Product Feature 80A05 80A07 Module Dimensions mmiin Weight Standard Option 10G kg lb 10GBASE W 9 953 Gb s m 0 25 Width Height Depth Net 10GBASE R 9 10 31 Gb s m 80E10 24 55 2 2 25 1 0 7513 0 0 175 0 37 10GB Fibre 10 51 Gbis 9 25 80E09 24 55 2 2 25 1 0 75 3 0 0 175 0 37 Channel 80E08 24 5512 2 25 1 0 7513 0 0 175 0 37 G 975 FEC 10 66 Gb s z t5 80E07 24 5512 2 25 1 0 7513 0 0 175 0 37 G 709 FEC 10 71 Gb s z 5 80E06 79 3 1 25 1 0 135 5 3 0 4 0 87 OIF CEI 11 Gb s 2 2 80E04 79 3 1 25 1 0 135 5 3 0 4 0 87 us on wi 11 10 Gb s 5 p5 e O en a s Additional enumerated standard 24 Remote module characteristics rates are supported with 8000 Series Firmware Releases 80A05 and 80A07 Electrical Clock Recovery Module higher than 2 4 x Product Feature 80A05 80A07 Clock Recovery Ranges for 50 Mb s to 50 Mb s to 100 Mb s to Standard Option 10G Custom User specified Rates 3 188 Gb s 3 188 Gb s 12 5 Gb s in addition to enumerated lists 4 25 Gb s 3 267 to continuous Supported Spec
4. Digital Serial Analyzer Sampling Oscilloscope DSA8200 Data Sheet Features amp Benefits State of the Art Sampling Oscilloscope for Communication Signal Analysis TDR TDT Serial Data Network Analysis Acquisition and Measurements of Repetitive Ultrafast Signals Acquisition of Spread Spectrum Clocking SSC Signals Industry s Only Mainframe to Support up to 8 Input Channels for Increased Flexibility and Throughput Four Color graded Variable Persistence Waveform Databases Measurement System with Over 100 Automated Measurements Complete Suite of Communications Measurements includes Both Types of OMA SSC Profile and Many Others Automated ITU ANSI IEEE Mask Testing Masks and Measurements for SONET SDH FC Ethernet and Other Standards Built in Mask Updates can be Loaded from Factory supplied File Mask Margin Testing for Guard Banding Production Testing Acquisition Modules Fully Integrated Multirate Optical Modules Optical Modules up to 80 GHz 80C10B High accuracy ER Calibrated Measurement Available in Some Modules Electrical Modules up to 70 GHz Bandwidth and 5 ps Measured Rise Time 10 90 Flexible Rate Clock Recovery Clock Recovery with SSC Spread Spectrum Clocking Support Available Jitter Noise BER and Serial Data Link Analysis Measures and Separates Deterministic Data dependent Jitter from Random Jitter Measures Vertical Noise Separating Deterministic Data dependent N
5. Suppression Ratio Ratio dB Peak to Peak Noise RMS Noise Q Factor SNR Average Optical Power dBm watts OMA Timing Rise Fall Period Bit Rate Bit Time Frequency Crossing measurements Level Time Cross Cross Jitter P P RMS Eye Width Width Width Burst Width Duty Cycle Duty Cycle Duty Cycle Distortion Delay Phase Area Area Cycle Area measurements Cursors Dot vertical bar and horizontal bar cursors Waveform Up to eight math waveforms can be defined and displayed Processing using the following math functions Add Subtract Multiply Divide Average Differentiate Exponentiate Integrate Natural Log Log Magnitude Min Max Square Root and Filter In addition measurement values can be utilized as scalars in math waveform definitions 16 wwwiektronix com Mask Testing Standard rate Gb s unless otherwise noted Custom masks a new FW feature can be used to distribute new Tektronix factory created NRZ updated masks as a file loadable by the firmware User defined masks allow the user to create through UI or Pl user masks For most applications mask will be found in the following list of predefined built in masks STM 0 OC 1 51 Mb s STM 1 OC 3 155 Mb s STM 4 OC 12 622 Mb s STM 16 OC 48 2 488 STM 64 0C 192 9 953 STM 256 OC 768 39 813 FEC 2 666 2 666 FEC 10 66 10 664 FEC 10 709 FEC 11 100 FEC 27 739 Gb s 100GBASE LR4 10
6. 26 FB N TE 9 05 Computer System and Peripherals 96 Gb s Characteristic Description OIF CEI 6 Gb s 4725 7 Operating System Windows XP 2x XAUI 6 25 Gb s E 5 CPU Intel Celeron 2 93 GHz processor 8 GB Fibre 8 50 Gb s 7 PC System Memory 512 MB Channel Hard Disk Drive Rear panel removable hard disk drive 40 GB capacity OC192 STM64 _ 9 953 Gb s DVD ROM CD RW _ Front panel DVD ReadOnly CD ReadWrite drive with XFP XFI 9 95 11 2 5 Drive CD creation software application 24 www tektronix com Input Output Ports Characteristic Description Front Panel USB 2 0 Port One USB 2 0 connector Anti static Banana jack connector 1 MQ Connection Trigger Direct Input See Trigger System specification Trigger Pre scale See Trigger System specification Digital Serial Analyzer Sampling Oscilloscope DSA8200 Ordering Information DSA8200 Digital Serial Analyzer Sampling Oscilloscope Includes User manual quick reference card MS Windows XP compatible keyboard and mouse touch screen stylus online help programmer online guide power cord With OpenChoice software Tektronix provides enhanced test and measurement analysis with the capability of full integration of third party software on the open Windows oscilloscopes By working with the industry leaders National Instruments and The MathWorks examples of software programs from these companies are featured on all Tektronix open Windows oscilloscopes
7. Performance under SSC is lower and depends on modulation shape Phase Reference Time Base Free Run Maximum timing deviation relative to phase reference signal 0 1 or better of phase reference signal period typical Sequential Time Base 14 Time interval accuracy horizontal scale lt 21 ps div 1 ps 1 of interval 221 ps div 8 ps 0 1 of interval short term optimized mode 8 ps 0 01 of interval locked to 10 MHz mode Horizontal Deskew Range Available Sequential time base only 500 ps to 100 ns on any individual channel in 100 fs increments DSA8200 Record Length 20 50 100 250 500 1000 2000 or 4000 samples Longer records available as follows IConnect 1 000 000 points 80SJNB Jitter Noise and BER Analysis software 3 200 000 points Waveform Databases 4 independently accumulated waveform records of up to 4 G waveform points Variable waveform database mode with true first in first out of 2000 waveforms available on each of 4 waveform databases Magnification Views 13 When using the 82A04 Phase Reference module In addition to the main time base the DSA8200 supports two magnification views These magnifications are independently acquired using separate time base settings which allow same or faster time div than that of the main time base 14 Traditional mode not using the 82A04 Phase Reference module 14 wwwiektronix com Trigger System Tri
8. and the Baltics 41 52 675 3777 Central Europe amp Greece 41 52 675 3777 Denmark 45 80 88 1401 Finland 41 52 675 3777 France 00800 2255 4835 Germany 00800 2255 4835 Hong Kong 400 820 5835 India 000 800 650 1835 Italy 00800 2255 4835 Japan 81 3 6714 3010 Luxembourg 41 52 675 3777 Mexico Central South America amp Caribbean 52 56 04 50 90 Middle East Asia and North Africa 41 52 675 3777 The Netherlands 00800 2255 4835 Norway 800 16098 People s Republic of China 400 820 5835 Poland 41 52 675 3777 Portugal 80 08 12370 Republic of Korea 001 800 8255 2835 Russia amp CIS 7 495 7484900 South Africa 41 52 675 3777 Spain 00800 2255 4835 Sweden 00800 2255 4835 Switzerland 00800 2255 4835 Taiwan 886 2 2722 9622 United Kingdom amp Ireland 00800 2255 4835 USA 1 800 833 9200 European toll free number If not accessible call 41 52 675 3777 Updated 25 May 2010 For Further Information Tektronix maintains a comprehensive constantly expanding collection of application notes technical briefs and other resources to help engineers working on the cutting edge of technology Please visit www tektronix com Copyright Tektronix Inc All rights reserved Tektronix products are covered by U S and foreign patents issued and pending Information in this publication supersedes that in all previously published material Specification and price change privileges reserved TEKTRONIX and TEK are r
9. 01 ER Calibrated 20 Channels 2 2 2 Reference Filter Repeatability Accuracy r F in Range Gb s Typical Input Impedance 50 Q nominal 50 Q nominal 50 Q nominal to itself Channel Input 1 85 mm 2 92 mm 3 5 mm and to other Connector 80Cxx Opt 01 Bandwidth 50 GHz 30 GHz 20 GHz 80C07B Option not available TDR Step 250 mV polarity 250 mV polarity 250 mV polarity 80C08C 9 9 11 3 0 6 0 39dB 1 2 0 76 dB Amplitude of either step may of either step may of either step may 0 42 dB at 12 dB 0 92 dB at 12 dB be inverted be inverted be inverted 80C10B Option not available TDR System 15 ps 20 ps 28 ps B0C11 99 11 3 40 6 0 300B 1 2 0 76 dB eoa 0 42 dB at 12 dB 0 92 dB at 12 dB 80C25CBE Onti iavailab DR System 12 ps 18 ps 23 ps puon nor avaliable Incident Rise Time 20 Low ER signals ER lt 6 dB signal passes 802 3ae like mask scaled horizontally for bit rate 105 samples TDR Step Deskew 250 ps 250 ps 50 ps in mask High ER signals ER gt 6 dB signal passes OC 192 like mask scaled horizontally for bit rate Range 105 samples in mask gt DR Sampler 250 ps 250 ps 100 ns 500 ps Deskew Range slot deskew only TDR Step 200 kHz 200 kHz 200 kHz Maximum Repetition Rate Physical Characteristics Module Dimensions mmiin Weight kg Ib Width Height Depth Net 80C07B 165 6 5 25 1 0 305 12 0 lt 1 36 lt 3 0 80C08C 165 6 5 25 1 0 305 12 0 lt 1 22 lt 2 7 80C10B 165 6 5 25 1 0 305 12 0 lt 2 61 lt
10. 953 Gb s 1OGBASE R 40GBASE LR4 10 31 Gb s 10G Fibre Channel 10 52 Gb s ITU T G 975 FEC 10 664 Gb s ITU T G 709 10 709 Gb s 10 GbE FEC 11 1 Gb s 10 GFC FEC 11 3 Gb s 40GBASE LR4 1100 nm to 1650nm 1310 nm and 1550 nm 20 nm 80012 1 to 8 5 Gb s Datacom Telecom Fibre Channel 1 063 Gb s 2G Fibre Channel 2 125 Gb s 4G Fibre Channel 4 250 Gb s 10GBASE X4 3 125 Gb s 8G Fibre Channel 8 50 Gb s 9 10GFC X4 3 1875 Gb s VSR5 3318 3 318 Gb s 1x Infiniband SDR 2 5 Gb s 10GBASE LRM 40GBASE SR4 100GBASE SR10 40GBASE LR4 10 Gb s Datacom Telecom OC 192 STM 64 9 953 Gb s 10GBASE W 9 953 Gb s 10GBASE R 40GBASE R4 100GBASE SR10 10 31 Gb s 10G Fibre Channel 10 52 Gb s ITU T G 975 FEC 10 664 Gbis ITU T G 709 10 709 Gb s 10 GbE FEC 11 1 Gb s 10 GFC FEC 11 3 Gbis 700 nm to 1650nm 850 nm 1310 nm and 1550 nm 20 nm 80C25GBE 100 Gb s Datacom 100GBASE LR4 25 781 Gb s FEC 27 739 Gb s 100GBASE ER4 25 781 Gb s FEC 27 739 Gb s 1310 nm and 1550nm_ 1310 nm and 1550 nm 20 nm 9 Draft version of the 8 5GFC filter T11 committee redefined this filter at the April 2008 meeting New 8 5GFC filter as defined by T11 committee in April 2009 is identical to the 10BASE R 10 313G filter and is available for 80012 Option 10G modules only and is identified as 10BASE R 16 Bandwidths shown are warranted unless printed in an italic typeface which represen
11. Duty cycle distortion DJ d d Deterministic jitter computed in the Dual Dirac model PJ Periodic jitter PJ h Horizontal component of periodic jitter PJ v Vertical component of periodic jitter EO at BER Horizontal eye opening at specified BER 80SJNB Noise Analysis Measurements Description RN Random noise RN v Vertical component of random noise RN h Horizontal component of random noise DN Deterministic noise DDN1 Data dependent noise on logical level 1 DDNO Data dependent noise on logical level 0 PN Periodic noise PN v Vertical component of periodic noise PN h Horizontal component of periodic noise EO at BER Vertical eye opening at specified BER SSC Magnitude Magnitude of SSC modulation in ppm SSC Frequency Frequency of SSC modulation in ppm 80SJNB Advanced Supports FFE Feed Forward Equalization to 100 Taps DFE Decision Feedback Equalization to 40 Taps Filter for support of linear filters from fixture de embed to transmitter equalization Channel emulation supported for channels with gt 30 dB of loss at 1st harmonic frequency 1 80SJARB File View Help om Source CH3 J2 Bit Time 102 0ps J9 Hits 10062 al iine 6 388ps 12 86ps Ti 1e 12 14 38ps Ri d d 930 7fs DJ d d 1 286ps Jitter Analysis of Arbitrary Data The 80SJARB jitter measurement application software for the DSA8200 Series addresses IEEE 802 3ba applications requiring the J2 and J9 jitter measurements It also enabl
12. Horizontal position is referenced to the trigger signal as with a traditional time base Free Run Phase Reference 3 Time Base Mode All timing is based on a phase reference signal accuracy and jitter as above no trigger is needed and correspondingly there is no timing relation to trigger signal Short term Optimized Sequential 14 Time Base Mode Locked to 10 MHz Reference Sequential Time Base Best short delay performance for acquisitions without the external phase reference signal Provides the best long delay performance for acquisitions without the external phase reference signal The Lock is selectable between Lock to Internal 10 MHz and Lock to External 10 MHz for highest frequency accuracy Main and Magnification View Time Bases 100 fs div to 5 ms div in 1 2 5 sequence or 100 fs increments Maximum Trigger Rate 200 kHz in Phase Reference mode 50 kHz Typical Acquisition Rate 150 kS s per channel standard sequential time base 50 kS s Phase Reference modes Time Interval Accuracy Standard Time Base and Timing Deviation Phase Reference Modes Phase Reference Time Base Triggered Maximum timing deviation relative to phase reference signal Horizontal position after trigger event gt 40 ns 0 2 of phase reference signal period typical lt 40 ns 0 4 of phase reference signal period typical Note The performance depends on stable clock supplied to the Phase Reference module
13. Hz frequency 115 V AC 10 400 Hz Environmental Characteristics Temperature Operating 10 C to 40 C Nonoperating 22 C to 60 C Relative Humidity Operating 20 to 80 at or below 40 C upper limit de rates to 45 Floppy disk relative humidity at 40 C and CD ROM not installed Nonoperating 5 to 90 at or below 60 C upper limit de rates to 20 relative humidity at 60 C Altitude Operating 3 048 m 10 000 ft Nonoperating 12 190 m 40 000 ft Electromagnetic 89 336 EEC Compatibility Safety UL3111 1 CSA1010 1 EN61010 1 IEC61010 1 International Power Plug Options Option Description Opt AO North America Opt A1 Universal EURO Opt A2 United Kingdom Opt A3 Australia Opt A4 240 V North America Opt A5 Switzerland Opt A10 China Opt A99 No power cord www tektronix com 25 Data Sheet Other Accessories Accessory Description Sampling Module Extender Cable 2 meter Order 80N01 not compatible with 80E10 80E09 80E08 or 80E07 modules SlotSaver Adapter Extender Cable Brings power and control to the 80A06 when operated externally from the mainframe saving slot space compatible with 80A06 and 80A02 Order 174 5230 xx 82A04 Filter 2 GHz Filter kit for non sinusoidal phase reference clock signal with frequency between 2 GHz and 4 GHz Order 020 2566 xx 82A04 Filter 4 GHz Filter ki
14. Module Characteristics Refer to Optical Sampling module s User Manual for more detailed information Optical Sampling Module Characteristics Module Application Type Standards and Supported Filtering Rates 16 Number of Input Channels 80C07B 80C08C Tributary Datacom Telecom 10 Gb s Datacom Telecom Standard Included OC 48 STM 16 2 488 Gb s Infiniband SDR 2 GbE 2 500 Gb s Optional choose any two OC 3 STM 1 155 Mb s OC 12 STM 4 622 Mb s Fibre Channel 1 063 Gb s GbE 1 250 Gb s 2G Fibre Channel 2 125 Gb s OC 192 STM 64 9 953 Gb s 10GBASE W 9 953 Gb s 10GBASE R 40GBASE R4 100GBASE SR10 10 31 Gb s 10G Fibre Channel 10 52 Gb s ITU T G 975 FEC 10 664 Gb s ITU T G 709 10 709 Gb s 10 GbE FEC 11 1 Gb s 10 GFC FEC 11 3 Gb s 10GBASE LRM 40GBASE SR4 100GBASE SR10 40GBASE LR4 1 Effective Calibrated Wavelength Range Wavelengths 700 nm to 1650 nm 780 nm 850 nm 1310 nm and 1550 nm 20 nm 700 nm to 1650 nm 780 nm 850 nm 1310 nm and 1550 nm 20 nm 80C10B 100 Gb s and 40 Gb s Telecom and Datacom OC 768 STM 256 39 813 Gb s OTU3 VSR 2000 G 693 40G NRZ G 959 1 FEC 43 018 Gb s OTU3 44 5 Gb s 4OGBASE FR 41 25 Gb s 100GBASE LR4 25 781 Gb s FEC 27 739 Gbis 100GBASE ER4 25 781 Gb s FEC 27 739 Gb s 1310 nm and 1550nm 1310 nm and 1550 nm 20 nm 80C11 10 Gb s Datacom Telecom OC 192 STM 64 9 953 Gb s 1OGBASE W 9
15. Offering true differential TDR measurements up to 50 GHz bandwidth with 15 ps reflected rise time and 12 ps incident rise time you are able to keep pace with today s most demanding Serial Data Network Analysis SDNA requirements The new 80E10 and 80E08 TDR modules feature a fully integrated independent dual channel 2 meter remote sampler system to minimize fixturing and assure optimal system fidelity Independent sampler deskew ensures fast and easy fixture and probe de embedding The user can characterize differential crosstalk by using TDR steps from a differential module to drive one line pair while monitoring a second line pair with a second differential module Digital Serial Analyzer Sampling Oscilloscope DSA8200 Small form factor remote sampler enables placement near DUT assuring optimal signal fidelity The DSA8200 is the industry s most versatile TDR measurement system accommodating up to 4 dual channel true differential TDR modules for fast accurate multilane impedance characterization The P80318 True differential TDR probe and P8018 Single ended Passive Handheld TDR probe provide high performance probing solutions for circuit board impedance and electrical signal characterization The P80318 an 18 GHz 100 Q input impedance differential TDR hand probe enables high fidelity impedance measurements of differential transmission lines The adjustable probe pitch enables a wide variety of differential line spacing and impe
16. accessory cables listed can be used P8018 20 GHz Single ended TDR Probe 80A02 module recommended for static protection of the sampling or TDR module P80318 18 GHz 100 Q Differential Impedance TDR Hand Probe 80A01 Pre scaled Trigger Amplifier Not required on the DSA8200 CSA8200 or TDS8200 mainframes with their increased sensitivity pre scaler The amplifier enhances pre scaler sensitivity on the older TDS8000B and CSA8000B mainframes 80A02 DSA8200 EOS ESD Protection module 1 channel P8018 TDR probe recommended 80A03 Enables the use of two Tektronix P7000 Series TekConnect probes on the DSA8200 or 8000 Series sampling oscilloscopes 82A04 Phase Reference module for low jitter acquisition with or without trigger Accepts signals from 2 GHz to 25 GHz external filter might be required below 8 GHz or to 60 GHz with Option 60G 80A05 Electrical Clock Recovery module Applicable to electrical signals and for the 80012 The standard version of 80A05 supports signals in the following ranges 50 Mb s 2 700 Gb s 2 700 Gb s 3 188 Gb s Rate of 4 Gigabit Fibre Channel 4 250 Gb s The Option 10G adds the ranges of 3 267 Gb s 4 250 Gb s 4 900 Gb s 6 375 Gb s 9 800 Gb s 12 60 Gb s 80A06 PatternSync module for 80SJNB jitter analysis package Programmable divider for creating a trigger pulse from patterns up to 223 in length 80A07 Electrical Clock Recovery module 80A07 recovers clocks from serial data streams for al
17. commercially available third party software packages Additionally TekVISA a standard software accessory allows the instrument to be placed under the control of software applications such as LabVIEW LabWindows Visual Basic Microsoft Excel C etc running on the instrument or on an external PC workstation s network connected to the instrument without the need of a GPIB hardware interface Plug and play drivers for LabVIEW and other programs are also supplied The DSA8200 combines the familiarity of Microsoft s Windows XP operating system with world class waveform acquisition technology This platform provides a wide array of standard instrumentation and communications interfaces including GPIB parallel printer port RS 232 C USB serial ports and an Ethernet LAN connection In addition the platform includes a DVD CD RW combo drive and removable hard drive for storage of waveforms setups and analysis results 155 Mb s to 12 Gb s Optical Test Tektronix optical modules for DSA8200 offer highest level of integration in the industry with corresponding higher repeatability and transferability of the result A particularly method sensitive measurement Extinction Ratio ER is now also available as ER Calibrated with an additional layer of improvement to the portability of the result 80CO8C and 80C11 modules only 80C08C 10 GHz Broad Wavelength Multirate 10 Gb s Optical Module The 80C08C is a broad wavelength 700 to 1650
18. for obtaining the desired frequency range and frequency step when performing S parameter measurements Up to 1 000 000 points can be acquired 2 When you employ IConnect Signal Integrity TDR and S parameter software with the DSA8200 you have an efficient easy to use and cost effective solution for measurement based performance evaluation of multi gigabit interconnect links and devices including signal integrity analysis impedance S parameter and eye diagram tests and fault isolation Connect can help you complete interconnect analysis tasks in minutes instead of days resulting in faster system design time and lower design costs IConnect also enables impedance S parameters and eye diagram compliance testing as required by many serial data standards as well as full channel analysis Touchstone SnP file output and SPICE modeling for gigabit interconnects 2 Long record lengths are supported only on DSA8200 CSA8200 TDS8200 CSA8000 and TDS8000 platforms 4 www tektronix com p Ine L a EES eld T NT Tee Sni 4 J VITOR wm PANNE a f Raw TDR confusing tee IN multiple retlections BE pna y NCaTION SH pet rong i Tme at AT Cust 17a 180 Sipi Qng Wy Quickly identify the exact location of faults with the 80E10 s sub millimeter resolution and IConnect True Impedance Profile Failure Analysis Quickly Identify Fault Location The 80E10 provides superior resolution enabli
19. for the TDR and connectivity to the popular TekConnect probing system brings you the performance of Tektronix state of the art probes for high impedance and differential probing Low impedance probes for 50 Q probing and for TDR probing are also available Jitter Noise BER and Serial Data Link Analysis High speed serial data link measurements and analysis are supported with three software solutions 80SJARB 80SJNB Essentials and 80SJNB Advanced 80SJARB is a basic jitter measurement tool capable of measuring jitter on any waveform random or repetitive The simplicity of acquisition limits the amount of analysis possible so only the simplest decomposition can be used repeatability is pattern dependent 80SJNB Essentials offers complete analysis of jitter noise and BER with decomposition of components for clear understanding of a signal s problems and margins The acquisition methodology requires a repetitive pattern Both accuracy and repeatability are improved relative to 80SJARB since the tool has access to the complete signal pattern 80SJNB Advanced adds features to 80SJNB Essentials for Serial Data Link Analysis de embedding of fixture channel emulation FFE DFE equalization pre emphasis de emphasis TDR and electrical modules with fully integrated remote sampler TDR Time Domain Reflectometry The DSA8200 is the industry s highest performance fully integrated Time Domain Reflectometry TDR measurement system
20. s The 80C10B module provides integrated and selectable reference receiver filtering enabling compliance testing at either 1310 nm or 1550 nm for 39 813 Gb s OC 768 STM 256 VSR2000 G 693 40G NRZ G 959 1 41 25 Gb s 40GBASE FR and 43 018 Gb s G 709 FEC OTU3 4x10G LAN PHY rates In addition to the filter rates the user may also choose selectable bandwidths of 30 GHz 65 GHz and 80 GHz for 80C10B for optimal noise vs bandwidth performance for accurate signal characterization The 80C10B is optionally available with Option F1 which extends filter selections to include 27 739 Gb s 100GBASE LR4 FEC and 100GBASE ER4 FEC and 25 781 Gb s 100GBASE LR4 and 100GBASE ER4 When equipped with Option CRTP an electrical signal pickoff is provided for clock recovery using an external module such as the Tektronix CR286A HS The 80C10B is also optionally available in a bundled ordering configuration which includes a 70 GHz electrical sampling channel 80C25GBE Multirate Datacom 100 Gb s 80C25GBE module provides 65 GHz full bandwidth with integrated selectable reference receiver filtering enabling compliance testing at either 1310 nm or 1550 nm for 27 739G 100GBASE LR4 FEC and 100GBASE ER4 FEC and 25 781G 100GBASE LR4 and www tektronix com 5 Data Sheet 100GBASE ER4 When equipped with Option CRTP an electrical signal Optical Modules 80C07B Module pickoff is provided for clock recovery using an external module su
21. 00 mV typical with increased jitter Short term Jitter Optimized Sequential Mode 800 fsaus 5 ppm of position typical 1 2 PSrms 10 ppm of position max Locked to 10 MHz Reference Sequential Mode 1 6 PSrms 0 04 ppm of position typical 2 5 PSrus 0 01 ppm of position max Internal Clock Adjustable from 25 to 200 kHz drives TDR internal clock output and calibrator 15 When using the 82A04 Phase Reference module performance under SSC is lower and depends on modulation shape clock recovering setting and cabling lengths Display Features Touch Screen Display 264 mm 10 4 in diagonal color Colors 16 777 216 24 bits Video Resolution 640 horizontal by 480 vertical displayed pixels Monitor Type LCD www tektronix com 15 Data Sheet Math Measurement Characteristic Description Characteristic Description System The DSA8200 supports up to eight simultaneous Measurements measurements updated three times per second with optional display of per measurement statistics min max mean and standard deviation Measurement Set Automated measurements include RZ NRZ and Pulse signal types and the following Amplitude High Low Amplitude Max Mid Min Width Eye Height measurements Eye Opening Factor Pulse Symmetry Peak to Peak OMA Overshoot Overshoot Mean Duty Cycle Cycle Mean RMS Cycle RMS AC RMS Gain Extinction Ratio Ratio dB
22. 0GBASE ER4 FEC 42 66 42 657 FEC 43 Gb s G 709 43 018 FC 10 G 10 5188 optical only FC 16 17 0 optical and electrical FC 133 132 813 Mb s optical and electrical FC 266 265 6 Mb s optical and electrical FC 531 531 2 Mb s optical and electrical FC 1063 1 063 optical and electrical FC 2125 2 125 optical and electrical FC 4250 4 250 optical and electrical FC 8500 8 500 optical and electrical optical 10GFC FEC 11 3 9 10GBASE X4 3 125 10GBASE W 9 953 10GBASE R 10 313 FEC 11 1 8 5 GFC 40GBASE LR4 41 25 OTU3 44 50 Gb s 4x10G LAN PHY 100GBASE LR4 and 100GBASE ER 4 25 781 Gb s InfiniBand 2 500 optical and electrical Gigabit Ethernet 1 250 Gigabit Ethernet 2 5 Gb s XAUI XFI PCI Express 2 5G PCI Express 5 0G SAS XR 3 0G SAS XR AASJ 3 0G SATA G1Tx 1 5G SATA G1Rx 1 5G SATA G2Tx 3 0G SATA G2Rx 3 0G SATA G3Tx 6 0G SATA G3Rx 6 0G Rapid I O 1 25G Rapid I O 2 50G Rapid 1 0 3 125 9 Draft version of the 8 5GFC filter T11 committee redefined this filter at the April 2008 meeting New 8 5GFC filter as defined by T11 committee in April 2009 is identical to the 10BASE R 10 313G filter and is available for 80C12 Option 10G modules only and is identified as 10BASE R Digital Serial Analyzer Sampling Oscilloscope DSA8200 Optical Sampling
23. 125 Gb s 3 188 Gb s 3 32 Gb s oe oe Oo oe ol ole 4 25 Gb s 5 7 7 o oe oe oe eo oe Oo o 8 5 Gb s 9 E Gi E E 80A07 9 95 Gb s 10 31 Gb s 9 10 52 Gb s 10 66 Gb s 10 71 Gb s 11 1 Gb s 11 3 Gb s el el ojo 7 With 80A05 or 80A07 8 With 80A05 Option 10G or 80A07 9 Draft version of the 8 5GFC filter T11 committee redefined this filter at the April 2008 meeting New 8 5GFC filter as defined by T11 committee in April 2009 is identical to the 10BASE R 10 3136 filter and is available for 80C12 Option 10G modules only and is identified as 10BASE R 8 www tektronix com DSA8200 Electrical Modules TDR Modules 80E10 80E08 and 80E04 The 80E10 80E08 and 80E04 are dual channel Time Domain Reflectometry TDR sampling modules providing up to 12 ps incident and 15 ps reflected rise time Each channel of these modules is capable of generating a fast impulse for use in TDR mode and the acquisition portion of the sampling module monitors the incident step and any reflected energy The polarity of each channel s step can be selected independently This allows for true differential or common mode TDR or S parameters testing of two coupled lines in addition to the independent testing of isolated lines The independent step generation for each channel allows true differential measurements which ensures measurement accuracy of nonlinear differ
24. 5 75 80C11 165 6 5 25 1 0 305 12 0 lt 1 22 lt 2 7 80012 165 6 5 25 1 0 305 12 0 lt 2 61 lt 5 75 80C25GBE 165 6 5 25 1 0 305 12 0 lt 2 61 lt 5 75 Electrical Sampling Module Characteristics Module Application Type Channels Input Impedance Channel Input Bandwidth 21 Connector 80E10 True differential TDR S parameters 2 50 1 0 O 1 85 mm female precision 50 40 30 GHz 11 22 and fault isolation adapter to 2 92 mm included with 50 Q SMA termination 80E09 High frequency low noise signal 2 50 1 0 Q 1 85 mm female precision 60 40 30 GHz 11 22 acquisition and jitter characterization adapter to 2 92 mm included with 50 Q SMA termination 80E08 True differential TDR and S parameters 2 50 1 0 Q 2 92 mm female 30 20 GHz 11 22 80E07 Optimal noise performance trade off 2 50 1 0 Q 2 92 mm female 30 20 GHz 11 22 for jitter characterization 80E06 High speed electrical device 1 50 0 5 O 1 85 mm female precision 70 GHz characterization adapter to 2 92 mm included with 50 Q SMA termination 80E04 TDR impedance and crosstalk 2 50 0 5 O 3 5 mm female 20 GHz 11 characterization 80E03 Device characterization 2 50 0 5 O 3 5 mm female 20 GHz 11 80E01 High frequency high maximum 1 50 0 5 Q 2 4 mm female precision 50 GHz operating range signal acquisition adapter to 2 92 mm included with 50 Q SMA termination 11 Calculated from 35 bandwidth rise time product 21 Values shown are warranted unless printed in an italic typeface which represents an u
25. A8200 80A07 Clock Recovery Module 80A07 recovers clocks from serial data streams for all of the most common electrical standards in the continuous 100 Mb s to 12 5 GB s range Auto locking capability is selectable from the user interface or programmatic interface so the design and test engineers can search and lock onto signals of undefined or unknown data rate The module accepts either single ended or differential signals as its input providing clock recovery for both The signal s is are then passed on to the output connectors and can be connected to sampling module s for differential or single ended sampling 80A07 offers complete configurability and state of the art specifications and is the preferred solution for most serial data standards due to excellent stability superior jitter and slew rate tolerance for recovering clocks from stressed or degraded signals and unequaled PLL bandwidth and roll off shape control for either Golden PLL compliance testing or custom PLL response 80A07 also locks on spread spectrum signals The 80A07 can also serve as the Clock Recovery module for the 80C12 Optical Sampling module P80318 Differential Handheld TDR Probe The P80318 is an 18 GHz 100 Q input impedance differential TDR hand probe This probe enables high fidelity impedance measurements of differential transmission lines The adjustable probe pitch from 0 5 mm to 4 2 mm enables a wide variety of differential line spacing and impedances The
26. Fidelity FrameScan Acquisition Mode with Eye Diagram Averaging Isolate Data dependent Faults Examine Low power Signals MS Windows XP Operating System Advanced Connectivity to 34 party Software Tektronix 7 Data Sheet Applications Design Verification of Telecom and Datacom Components and Systems Manufacturing Testing for ITU ANSI IEEE SONET SDH Compliance High performance True differential TDR Measurements Advanced Jitter Noise and BER Analysis Impedance Characterization and Network Analysis for Serial Data Applications including S parameters Channel and Eye Diagram Simulation and Measurement based SPICE Modeling 1 Typical with the Phase Reference module some conditions apply Without the module the jitter is lt 800 fSrus typical Superior Performance with Extraordinary Versatility For developing today s high speed serial devices the DSA8200 Digital Serial Analyzer sampling oscilloscope is the most versatile tool for communication computer and consumer electronics gigabit transmitter and signal path characterization and compliance verification With exceptional bandwidth signal fidelity and the most extensible modular architecture the DSA8200 provides the highest performance TDR and interconnect analysis most accurate analysis of signal impairments and BER calculations for current and emerging serial data technology The DSA8200 provides unmatched measurement system fidelity with ultra lo
27. P80318 probe also includes two precision SMA cables with parallel control lines that provides the 80A02 module the control for EOS ESD protection P8018 Single ended Handheld TDR Probe The P8018 Handheld TDR Probe is a 20 GHz 50 Q input impedance single ended passive probe that provides a high performance solution for electrical sampling TDR circuit board impedance characterization and high speed electrical signal analysis applications The P8018 probe also includes a precision SMA cable and parallel control line that provides the 80A02 module the control for EOS ESD protection 80A02 EOS ESD Protection Module The 80A02 EOS ESD Protection module protects the sampling bridge of Tektronix electrical sampling module inputs from damage by electrostatic charge The 80A02 is intended for use in applications such as electrical TDR circuit board testing and cable testing where large static charges can be stored in the DUT When used with the matching P8018 20 GHz single ended handheld probe or the P80318 differential handheld probe both with probe tip pressure actuating feature the 80A02 provides a superior technique and performance capability for electrical module EOS ESD protection of acquired electrical signals and TDR measurements two 80A02 modules required for differential applications www tektronix com 11 Data Sheet 80A03 TekConnect Probe Interface Module The 80A03 provides probe power and control for up to two Tektronix P7000 S
28. ch as the Tektronix CR286A HS 80C07B Opt F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 CR1 Bandwidth 2 5 2 5 2 5 2 5 2 5 GHz 2 5 2 5 2 5 2 5 2 5 2 5 Wavelength 700 1650 700 1650 700 1650 700 1650 700 1650 Range nm 700 1650 700 1650 700 1650 700 1650 700 1650 700 1650 Fibre Input Qor50or 9or50or 9or50or 9or50or Y9or50or um 62 5 62 5 62 5 62 5 62 5 9or50or 9or50or 9or50or 9or50or 9or50or 9 or50 or 62 5 62 5 62 5 62 5 62 5 62 5 Mask Test 22 22 22 22 22 Sensitivity dBm 22 22 22 22 22 22 Number of l 1 1 1 1 Channels Rates Supported m Filter Optical Clock Recovery Electrical Clock Recovery 125 Mb s 3 L E H 155 Mb s L E H 7 622 Mb s H 1063 Mb s E 1250 Mb s H 2125 Mb s 2488 Mb s 2500 Mb s oe oe eo eo o 3 125 Gb s 3 188 Gb s 3 32 Gb s 4 25 Gb s 9 95 Gb s 3 125 Mb s is supported by selecting 155 Mb s rate 6 www tektronix com Digital Serial Analyzer Sampling Oscilloscope DSA8200 Optical Modules 80C08C 80C10B 80C11 and 80C25GBE Module 80C08C 80C10B 5 80C11 80C25GBE Opt CR1 CR2 CR4 CRTP F1 CR1 CR2 CR3 CR4 CRTP Bandwidth 10 10 10 10 80 65 30 30 30 30 30 65 GHz Wavelength 700 1650 700 1650 700 1650 700 1650 1290 1330 1290 1330 1100 1650 1100 1650 1100 1650 1100 1650 1100 1650 1290 1330 Range 1520 1620 1520 1620 1520 1620 nm Fibre 9or50or 9or50or 9or50or 9 or 50 or 9 9 9 9 9 9 9 9 Inpu
29. dances The P8018 is a 20 GHz Single ended Passive Handheld TDR probe Both the P80318 and P8018 can be used as stand alone probes but are especially designed to work with the 80A02 for the control of EOS ESD protection www tektronix com 3 Data Sheet Gigabit Signal Path Characterization and Analysis Serial Data Network Analysis SDNA As clock speeds and rise times of digital circuits increase interconnect signal integrity dramatically affects digital system performance Accurate and efficient Serial Data Network Analysis SDNA of the signal path and interconnects in time and frequency domains is critical to predict signal losses jitter crosstalk terminations and ringing digital bit errors and eye diagram degradation ensuring reliable system operation Tektronix offers several true differential TDR modules which in combination with IConnect software allow S parameters measurements with up to 70 dB of dynamic range This performance assures accurate repeatable measurement in serial data analysis digital design signal integrity and electrical compliance testing applications The table below summarizes the S parameter measurement bandwidth performance when IConnect and the true differential TDR modules are used in combination TDR Module S parameter Measurement Bandwidth Performance 80E10 50 GHz 80E08 30 GHz 80E04 20 GHz With the long record length acquisitions Connect provides great flexibility
30. ectrical modules provides the industry s best noise performance with remote samplers featuring 450 UVams noise at 60 GHz and 300 UVams at 30 GHz DSA8200 optical modules provide complete optical test solutions with superior system fidelity from 125 Mb s to 43 Gb s and beyond The modules cover a range of wavelengths for both single and multi mode fibres Each module can be optionally configured with a number of selectable data rate filters optical reference receivers ORR and or a full bandwidth path The 80C07B 80C08C and 80011 can be configured with a number of available flexible integrated clock recovery options The 80012 Multirate module clock recovery support is achieved with an electrical output for use with the 80A05 or 80A07 Electrical Clock Recovery modules The DSA8200 s popular FrameScan acquisition mode can be used with patterns from DUTs BERTs and other sources to isolate pattern dependent effects in transmitters or show the bit sequence preceding a mask violation FrameScan automatically sequences the time base so that each bit of the data stream is acquired in time order When used in combination with mask testing conditional acquisition features of the DSA8200 such as stop after mask hits FrameScan can automatically identify at which bit a pattern dependent failure occurred In addition specialized modules supporting features such as single ended and differential electrical clock recovery electrostatic protection
31. egistered trademarks of Tektronix Inc All other trade names referenced are the service marks trademarks or registered trademarks of their respective companies 21 Jun 2010 85W 17654 17 Tektronix
32. ential devices 80E10 and 80E08 feature a small form factor fully integrated independent 2 meter remote sampler system enabling the location of the sampler near the DUT for the best system fidelity The modules characterize crosstalk by TDR Module Summary Digital Serial Analyzer Sampling Oscilloscope DSA8200 using TDR steps to drive one line or line pair for differential crosstalk while monitoring a second line or line pair with the other channel or another module for differential crosstalk The rise time filter function on the DSA8200 mainframe can be used with TDR or crosstalk measurements to characterize expected system performance with slower edge speeds An optional 2 meter extender cable for the 80E04 is available which enables placement of the module near the DUT for the best system fidelity All modules have independent incident step and receiver deskew to remove the effect of fixtures and probes enabling faster and easier deskew The 80E10 Sampling module provides an acquisition rise time of 7 ps with up to 50 GHz user selectable equivalent bandwidth with 50 GHz 40 GHz and 30 GHz settings 80E08 sampling bandwidth is 30 GHz user selectable with 30 GHz and 20 GHz settings and 80E04 sampling bandwidth is 20 GHz The 20 GHz P8018 single ended and the 18 GHz P80318 differential variable pitch TDR handheld probes provide excellent performance ensuring easy and accurate backplane and package measurements
33. eries probes The 80A03 is powered through the oscilloscope and requires no user adjustments or external power cords An Electrical Sampling module can be plugged directly into the slot on the 80A03 to provide the optimum system fidelity and a short electrical path Using the 80A03 designers can benefit from industry leading Tektronix active and differential probes to measure signals on SMD pins and other challenging circuit features SlotSaver Small Module Extender Cable This cable can be used to power and operate one 80A01 12 80A02 or 80A06 accessory modules eliminating the need to consume a small form factor mainframe slot The SlotSaver extender cable plugs into the Trigger Power connector on the mainframe or for 80A01 and 80A02 into the Probe Power connector on most Electrical Sampling modules 12 Now obsolete module useful with older versions of the mainframe but not needed with the 8200 Series mainframes DSA8200 Application Software Jitter Noise BER and Serial Data Link Analysis SDLA Software 80SJNB speeds the identification of the underlying causes of both horizontal and vertical eye closure through separation of jitter and noise With its unique insight into the constituent components of both jitter and noise 80SJNB provides a highly accurate and complete BER calculation and eye contour analysis Additionally available in the software package is the first ever set of features addressing the design iss
34. es basic jitter measurements for NRZ data signals including PRBS31 random traffic and scrambled data This provides an entry level jitter analysis capability with simple Dual Dirac model jitter analysis and no hardware module requirements 80SJARB can acquire continuously in free run mode delivering acquisitions and updates beyond the IEEE minimum requirement of 10 000 data points Plots include jitter bathtub curves for both measured and extrapolated data as well as a histogram of the acquired data Measurement Description J2 Total jitter for BER 2 5e 3 J9 Total jitter for BER 2 5e 10 Tj Total jitter for BER 1 0e 12 DJdd Deterministic jitter Dual Dirac model RJdd Random jitter Dual Dirac model Free Run Mode For continuous acquisitions and update beyond the IEEE minimum requirement of 10 000 data points Plots Jitter Eye Opening Bathtub Histogram of Acquired Data Digital Serial Analyzer Sampling Oscilloscope DSA8200 IConnect Signal Integrity TDR and S parameter Software Operating on the DSA8200 TDR platform IConnect S parameters is the most cost effective and highest throughput approach for S parameter measurements in digital design signal integrity analysis and interconnect compliance testing providing as much as 50 cost savings compared to similar bandwidth VNAs and dramatically speeding up measurements You can also take advantage of the IConnect S parameters command line interface w
35. from Maury Microwave These components accessible at www maurymw com tektronix htm are compatible with the 2 92 mm 2 4 mm and 1 85 mm connector interface of the 80Exx modules Cal kits and other components can be ordered by contacting Maury Microwave Digital Serial Analyzer Sampling Oscilloscope DSA8200 Interconnect Cables 015 0560 xx 450 mm 18 in 1 dB loss at 20 GHz cable is a high quality cable recommended for work up to 20 GHz Cable Frequency Connectors Length Bench Top Test Cable Assemblies TEK40PF18PP 40 GHz 2 92 mm male 18 0 inches TEK50PF18PP 50 GHz 2 4 mm male 18 0 inches TEK65PF18PP 65 GHz 1 85 mm male 18 0 inches High frequency Interconnect Cables for Electrical Sampling Modules TEK40HFO6PP 40 GHz 2 92 mm male 6 0 inches TEK40HFO6PS 40 GHz 2 92 mm male 6 0 inches 2 92 mm female TEK50HFO6PP 50 GHz 2 4 mm male 6 0 inches TEK50HFO6PS 50 GHz 2 4 mm male 6 0 inches 2 4 mm female TEK65HFO6PP 65 GHz 1 85 mm male 6 0 inches TEK65HFO6PS 65 GHz 1 85 mm male 6 0 inches 1 85 mm female CE ge ISO 9001 Product s are manufactured in ISO registered facilities www tektronix com 27 Data Sheet www tektronix com Contact Tektronix ASEAN Australasia 65 6356 3900 Austria 00800 2255 4835 Balkans Israel South Africa and other ISE Countries 41 52 675 3777 Belgium 00800 2255 4835 Brazil 55 11 3759 7600 Canada 1 800 833 9200 Central East Europe Ukraine
36. gger Sources External direct trigger External pre scaled trigger Digital Serial Analyzer Sampling Oscilloscope DSA8200 Clock recovery triggers from Optical Sampling modules and from the 80A05 or 80A07 Rlectrical Clock Recovery modules signal from the 80A05 module pre scaled above 2 7 Gb s internally connected Phase Reference 3 time base supports acquisitions without a trigger signal in its Free Run mode Internal clock trigger Internally connected to direct trigger 13 When using the 82A04 Phase Reference module Trigger Sensitivity External Direct Trigger Output 50 mV DC 4 GHz typical 100 mV DC 3 GHz guaranteed Trigger Level Range t1 0V Trigger Input Range t15V Trigger Holdoff Adjustable 5 us to 100 ms in 0 5 ns increments External Trigger Gate Optional TTL logic 1 enables gate a TTL logic 0 disables gate maximum nondestruct input level 5 V Pre scaled Trigger Input 200 mV to 800 MVp p 2 to 12 5 GHz guaranteed Time base Jitter Phase Reference 5 Time Base System jitter of 200 fSrus typical on a 10 GHz or faster acquisition module with f gt 8 GHz 0 6 V lt VREF lt 1 8 V phase reference signal Jitter System jitter of 280 fSrus typical on a 10 GHz or faster acquisition module in DSA8200 mainframe with 2 GHz lt f lt 8 GHz 0 6 V lt VREF lt 1 8 V phase reference signal The phase reference time base remains operational to 1
37. hich automates the S parameter measurements to the overall suite of manufacturing tests you perform using your TDR instrument significantly reducing test time while increasing measurement repeatability The simplicity of S parameter calibration using a reference open short or through and an optional 50 Q load makes the measurement fixture de embedding and moving the reference plane a snap Touchstone file format output enables easy S parameter file sharing for further data analysis and simulations Tektronix offers several true differential TDR modules which in combination with Connect offers S parameter measurements to 50 GHz with up to 70 dB of dynamic range This performance exceeds requirements for serial data analysis digital design and signal integrity applications resolving down to 1 40 dB accuracy of crosstalk whereas electrical compliance testing masks typically call for the measurements in the 10 to 30 dB range IConnect software allows you to quickly and easily generate SPICE and IBIS models for your PCBs flex boards connectors cables packages sockets and I O buffer inputs directly from TDR T or VNA S parameter measurements IConnect allows you to display eye diagram degradation jitter loss crosstalk reflections and ringing in your digital system IConnect Linear Simulator allows the designer to link several interconnect channels together to evaluate the total time frequency domain performance a
38. ical Module Summary with the optional 2 meter extender cable ensuring superior system fidelity and measurement flexibility The 80E03 is a dual channel 20 GHz sampling module This module provides an acquisition rise time of 17 5 ps or less An optional 2 meter extender cable is available When used with Tektronix 80SJNB Jitter Noise and BER Analysis software these modules enable separation of both jitter and noise into their constituent components for insight into the underlying causes of eye closure and obtain highly accurate calculation of BER and 3 D eye contour When used with the 82A04 Phase Reference module time base accuracy can be improved down to 200 fspus jitter which together with the 300 UVrus noise floor and 14 bits of resolution ensures the highest signal fidelity for your measurements Electrical Step Response at Full Number Of Channels Bandwidth 0 12 RMS Noise at Remote Sampler Module Bandwidth Bandwidth 10 10 90 19 80E09 5 8 ps 2 60 40 30 GHz user 60 GHz 450 pV Yes fully integrated selectable 40 GHz 330 uV 2 meter cable 30 GHz 300 uV 80E07 11 7 ps 2 30 20 GHz user 30 GHz 300 uV Yes fully integrated selectable 20 GHz 280 uV 2 meter cable 80E06 5 0 ps 1 70 GHz 1 8 mV No optional 80N01 2 meter extender cable 80E03 17 5 ps 2 20 GHz 600 uV No optional 80N01 2 meter extender cable 80E01 7 ps 1 50 GHz 1 8 mV No optional 80N01 2 meter extender cable 10 Values show
39. ides telecom rate testing at 9 95 10 66 and 10 70 Gb s With its amplified O E design this module provides excellent signal to noise performance and high optical sensitivity allowing users to examine low power level optical signals Clock recovery for the 80C12 is provided through the 80A05 or 80A07 Clock Recovery modules sold separately 80C11 30 GHz Long Wavelength Multirate 10 Gb s Optical Module The 80C11 is optimized for testing of long wavelength signals 1100 to 1650 nm at a number of rates around 10 Gb s with a highly flexible multirate filter Additionally the high optical bandwidth of 30 GHz typical and the excellent frequency response of its full bandwidth path is well suited for general purpose high performance optical component testing The 80C11 can be configured with clock recovery options that supports any standard or user defined rate from 9 8 to 12 6 Gb s 80C07B 2 5 GHz Broad Wavelength Multirate 155 Mb s to 2 5 Gb s Optical Module The 80C07B is a broad wavelength 700 to 1650 nm multirate optical sampling module optimized for testing datacom telecom signals from 155 to 2500 Mb s With its amplified O E design this module provides excellent signal to noise performance allowing users to examine low power optical signals The 80C07B can be optionally configured with multirate clock recovery that operates from 155 to 2 7 Mb s 40 Gb s and 100 Gb s Optical Test 80C10B Multirate Datacom and Telecom 40 Gb s and 100 Gb
40. ifications above 4 25 Gb s Enumerated Standards 4 900 to OC3 STM1 155 52 Mb s a 7 0725 ae we eo 2 STM4 622 08 Mb s m m 12 60 Gb s Fibre Channel __1 063 Gb s a S a Sensitivity Clock recovery will lock differential data is given for each input Gigabit 1 25 Gb s A zi Lowest Supported Rate to Differential lt 8 mMVpp Differential Ethernet 2 70 Gb s Single Ended 10 mV 15 mV typ SAS Gen 1 50 Gb s 4 26 4 26 2 70 to 11 19 Gb s Differential Single Ended 2 GB Fibre 2 125 Gb s m m lt 12 MVpp 30 MV typ Channel Single Ended OC48 STM16 2 488 Gb s 7 7 7 15 MV 2 GB Ethernet 2 50 Gb s 7 11 19 to 12 60 Gb s Differential lt 15 mV PCIExpress 2 50 Gb s 4 2 42 7 Single Ended Infiniband 2 50 Gb s B L 25 20 mV 2 5G G 709 2 666 Gb s 7 a o 25 9 Draft version of the 8 5GFC filter T11 committee redefined this filter at the April 2008 meeting New 8 5GFC FEC filter as defined by T11 committee in April 2009 is identical to the 10BASE R 10 313G filter and is available SAS Gen II 3 0 Gb s 26 425 m for 80C12 Option 10G modules only and is identified as 10BASE R XAUI P Gb a 25 The standard is not enumerated but is supported as a custom rate 10GBASE X 3 125 Gb s 26 No spread spectrum clocking support a a 225 eai elles Cols DSA8200 Mainframe Physical Characteristics 4 GB Fibre 4 25 Gb s 7 m 7 Dimensions mmi in Weight kg Ib Channel Width Height Depth Net FB DIMM1 a o eSa s 457118 0 343 13 5 419116 5 21 46 PCI E ll 5 0 Gb 9725
41. l of the most common electrical standards in the continuous 100 Mb s to 12 5 GB s range Applicable to electrical signals and for 80C12 80SJARB 80SJARB Jitter Analysis of Arbitrary Data software Provides a basic jitter measurement tool capable of measuring jitter on any waveform random or repetitive Also see Opt JARB 80SJNB Essentials 80SJNB Essentials with Jitter Noise and BER Analysis software Provides separation of jitter and noise into their constituent components and provides highly accurate eye opening and BER calculations Also see Opt JNB JNB01 80SJNB Advanced 80SJNB Advanced adds equalization channel emulation fixture de embedding Also see Opt JNB JNB01 26 www tektronix com Interconnect Cables 3rd Party Tektronix recommends using quality high performance interconnect cables with these high bandwidth products in order to minimize measurement degradation and variations The W L Gore and Associates cable assemblies listed below are compatible with the 2 92 mm 2 4 mm and 1 85 mm connector interface of the 80Exx modules Assemblies can be ordered by contacting Gore by phone at 800 356 4622 or on the Web at www gore com tektronix Calibration Kits and Accessories 3rd Party To facilitate S parameter measurements with the new 80E10 80E08 and 80E04 electrical TDR modules and Connect software we recommend precision calibration kits adapter kits connector savers airlines torque wrenches and connector gauges
42. n 6 10 or less for the first 400 ps following step transition 0 4 or less over the zone 400 ps to 3 ns following step transition 1 2 or less over the zone 3 ns to 100 ns following step transition 1 after 100 ns following step transition 50 GHz 600 uV lt 700 uV 40 GHz 370 uV 480 uV 30 GHz 300 uV lt 410 uV 80E09 10 mV to 1 0 V full scale 2 mV 0 007 Offset 0 02 Vertical Value Offset 1 or less over the zone 10 ns to 20 ps before step transition 6 10 or less for the first 400 ps following step transition 0 4 or less over the zone 400 ps to 3 ns following step transition 1 2 or less over the zone 3 ns to 100 ns following step transition 1 after 100 ns following step transition 60 GHz 450 uV lt 600 pV 40 GHz 330 uV 480 uV 30 GHz 300 uV lt 410 uV 80E08 10 mV to 1 0 V full scale 2 mV 0 007 Offset 0 02 Vertical Value Offset 1 or less over the zone 10 ns to 20 ps before step transition 6 10 or less for the first 400 ps following step transition 0 4 or less over the zone 400 ps to 3 ns following step transition 1 2 or less over the zone 3 ns to 100 ns following step transition 1 after 100 ns following step transition 30 GHz 300 HV lt 410 pV 20 GHz 280 uV lt 380 uV 80E07 80E06 23 10 mV to 1 0 V full scale 10 mV to 1 0 V full scale 2 mV 0 007 Offset 0 02 Vertical Value Offse
43. n are warranted unless printed in an italic typeface which represents a typical value 12 Now obsolete module useful with older versions of the mainframe but not needed with the 8200 Series mainframes 10 wwwiektronix com DSA8200 Accessory Modules 82A04 Phase Reference Module The 82A04 Phase Reference module enhances the DSA8200 sampling oscilloscope from the industry s standard time base jitter performance of 800 fspus to the extremely low time base jitter of lt 200 fsaus Typical application for the Phase Reference module is the acquisition and analysis of very high speed optical and electrical signals in communication devices and systems The 82A04 supports both the Triggered mode of operation which is similar to usual acquisition and the untriggered Free Run mode where all timing information comes from the customer supplied clock alone no trigger signal necessary When the external clock is not available the module can accept the clock signal from the clock recovery output of the 80Cxx modules as well as from the 80A05 or 80A07 Clock Recovery modules Additionally 82A04 supports SSC Spread Spectrum Clocking operation 80A05 Electrical Clock Recovery Module The 80A05 Electrical Clock Recovery module enables clock recovery for electrical signals as well as internal triggering on the recovered clock The module recovers clocks from serial data streams for all of the most common electrical standards in the 50 Mb s to 4 25 Gb
44. nd eye diagram of the overall channel IConnect substantially simplifies the signal integrity analysis of the interconnect link equalization and emphasis component design and analysis of the interconnect link with transmitter and receiver www tektronix com 13 Data Sheet Characteristics Signal Acquisition Acquisition Modes Mode Sample Normal Envelope and Average Number of Sampling Modules Up to four dual channel electrical up to two optical sampling modules Both single and dual channel modules are appropriate Accommodated for the two channels associated with the slot Population of the CH1 CH2 large slot with any module other than one requiring power only displaces functionality of the CH1 CH2 small slot population of the CH3 CH4 large slot with any module other than one requiring power only displaces functionality of the CH3 CH4 small slot Number of Simultaneously Acquired Inputs Eight channels maximum Acquisition Characteristics Characteristic Description Vertical Systems Rise Time Bandwidth Determined by the sampling modules used Vertical Resolution 14 bits over the sampling modules dynamic range Horizontal System Four time base modes are available Triggered Phase Reference 3 Time Base Mode Timing information extracted from a user supplied or clock recovery signal significantly improves time base accuracy and jitter performance of the triggered acquisition
45. ng the fastest and most efficient fault isolation in package circuit board and on chip failure analysis applications Advanced Communication Signal Analysis Specifically designed for ultra high performance optical and electrical serial data applications the DSA8200 is the ideal tool for design characterization and validation as well as manufacturing test of datacom and telecom components transceiver subassemblies and transmission systems The DSA8200 generates measurement results not just raw data with time and amplitude histograms mask testing and statistical measurements It provides a communications tailored measurement set that includes jitter noise duty cycle overshoot undershoot OMA extinction ratio Q factor mean optical power and amplitude In addition you can do mask testing of SONET SDH 100 Gigabit 4x25 10 Gigabit Gigabit Ethernet and other electrical and optical standards compliance verification Color grading and grayscale grading of waveform data adds a third dimension sample density to your signal acquisitions and analysis to provide visual insight In addition the variable persistence database feature enables exact data aging to all of the functions and facilitates eye measurements on DUTs under adjustment OpenChoice Software Enables Familiar Tools to Extend Your Measurement System The DSA8200 provides an open Windows environment offering new levels of data analysis on the instrument using your favorite
46. nm multirate optical sampling module providing datacom rate testing for 10GbE applications at 9 95 10 31 11 09 Gb s and 10G Fibre Channel applications at 10 51 Gb s The 80C08C also provides telecom rate testing with several filters between 9 95 and 11 3 Gb s With its amplified O E design this module provides excellent signal to noise performance and high optical sensitivity allowing users to examine low power level optical signals The 80C08C can be optionally configured with clock recovery options that can support any standard or user defined rate in a continuous range from 9 8 to 12 6 Gb s 80C12 Up to 10 GHz Broad Wavelength Multirate 1 Gb s to 10 Gb s Optical Module The 800012 is a broad wavelength 700 to 1650 nm multirate optical sampling module providing 1G 2G and 4G telecom and datacom testing This highly flexible module can be configured to support either lower data rate applications 1 to 4 Gb s or a wide variety of 10 Gb s applications The low data rate applications include 1 2 4 and 8 Fibre Channel and by 4 wavelength division multiplex standards such as 10GBASE X4 and 4 Lane 10 Gb s Fibre Channel The supported 10 Gb s applications include both datacom and telecom The supported 10 Gb s datacom applications include 10GbE at 9 95 10 31 11 09 Gb s 8G Fibre Channel and 10G Digital Serial Analyzer Sampling Oscilloscope DSA8200 Fibre Channel applications at 8 5 Gb s 10 51 and 11 3 Gb s The 80012 also prov
47. nwarranted characteristic value that the instrument will typically perform to 22 User selectable 20 www tektronix com Digital Serial Analyzer Sampling Oscilloscope DSA8200 Electrical Sampling Module Characteristics Cont Module Rise Time Dynamic Range Offset Range Maximum Operating Maximum Vertical Number of 10 90 Voltage Nondestruct Digitized Bits Voltage DC AC 80E10 7 ps 1 1 0 Vo 1 1V 1 1V 2 0 V 14 bits full scale 80E09 5 8 ps 11 1 0 Vo 11V 11V 2 0 V 14 bits full scale 80E08 11 7 ps 1 1 0 Vo 1 1V 11V 2 0 V 14 bits full scale 80E07 11 7 ps 1 1 0 Vo 11V 1 1V 2 0 V 14 bits full scale 80E06 5 0 ps 23 1 0 Vo 16 V 16V 2 0 V 14 bits full scale 80E04 17 5 ps 1 0 Vp p 16 V 16V 3 0 V 14 bits full scale 80E03 17 5 ps 1 0 Vp p 16 V 16V 3 0 V 14 bits full scale 80E01 11 7 ps 1 1 0 Vp 16 V 16V 2 0 V 14 bits full scale 11 Calculated from 35 bandwidth rise time product 23 Calculated from formula rise time 0 35 typical bandwidth www tektronix com 21 Data Sheet Electrical Sampling Module Characteristics Cont Module Vertical Sensitivity Range DC Vertical Voltage Accuracy Single Point within 2 C of Compensated Temperature Typical Step Response Aberrations RMS Noise 10 80E10 10 mV to 1 0 V full scale 2 mV 0 007 Offset 0 02 Vertical Value Offset 1 or less over the zone 10 ns to 20 ps before step transitio
48. ock 16 highest responsivity Option CR3 9 953 Gb s 10 709 Gb s Option CR4 Continuous between 9 8 Gb s to 12 6 Gb s 80012 Provided by 80A05 or 80A07 ELECTRICAL SIGNAL OUT 9 GHz for all options 1 mW average 10 mW 62 5 125 um sold separately except 10G peak power at wavelength of Multi Mode 10 GHz Option 10G highest responsivity 80C25GBE Provided by CR286A HS ELECTRICAL SIGNAL OUT 65 GHz 20 mW average 60 mW 9 ym 125 ym to 44 5 Gb s 50 Q AC peak power at wavelength of Single Mode coupled differential 2 92 mm female connectors max 1 ps diff skew 17 highest relative responsivity 4 Contact Tektronix for details 16 Bandwidths shown are warranted unless printed in an italic typeface which represents a typical value 80C08C 80C12 Bandwidths and optical filters valid for OMA lt 500 pW 1550 1310 nm OMA lt 860 uW 850 nm OMA 1020 pW 780 nm 17 With Option CRTP 18 Frequency characteristic and ORR guaranteed for signals up to 500 UW 80C08C 80C 12 respectively 200 uW 80C07B at 1550 nm pro rated higher power for other wavelengths 18 www ektronix com Digital Serial Analyzer Sampling Oscilloscope DSA8200 Optical Sampling Module Characteristics Cont Module Optical Return Fibre Input RMS Optical Noise Typical RMS Optical Noise Maximum Independent Loss Accepted Channel Deskew 80C07B gt 14 dB Multi Mode Single or Multi Mode 0 50 uW at 155 Mb s 622 Mb s 1 0
49. oise from Random Noise Highly Accurate BER and Eye Contour Estimation Support for DDPWS FFE DFE Equalization Transmitter Equalization Channel Emulation for Channels with gt 30 dB of Loss Linear Filter for Fixture De embedding Linear Filtering TDR Time Domain Reflectometry Up to 50 GHz TDR Bandwidth with 15 ps Reflected Rise Time and 12 ps Incident Rise Time Lowest Noise for Accurate Repeatable TDR Measurement Results 600 UVams at 50 GHz Independent Sampler Deskew ensures Easy Fixture and Probe De embedding Industry s Only Mainframe to Accommodate up to Four True differential TDR or Electrical Channel Pairs for Increased System Versatility S parameters Measurements Up to 50 GHz Differential Single Ended Mixed Mode Insertion Return Loss Frequency Domain Crosstalk PCI Express Serial ATA Infiniband Gigabit Ethernet Manufacturing and Standard Compliance Testing for Gigabit Signal Path and Interconnects Including Eye Mask Tests Intuitive Easy and Accurate for Serial Data Gigabit Digital Design and Signal Integrity Fast and Accurate Automated Multiport S parameter Measurements with Command Line Interface Industry s Best Standard Time base Jitter Performance 800 fsrus Industry leading Time base Jitter Performance lt 200 fspus Available with Phase Reference Mode Fast Acquisition Rate and High Throughput True differential Remote Sampler enabling Placement Near DUT for Superior Signal
50. ollowing step transition 3 or less over the zone 10 ns to 20 ps before step transition 12 5 or less for the first 300 ps following step transition 5 5 3 or less over the zone 300 ps to 3 ns following step transition 1 or less over the zone 3 ns to 100 ns following step transition 0 5 after 100 ns following step transition 600 uV 1 2 mV maximum 1 8 mV 2 3 mV maximum 10 Values shown are warranted unless printed in an italic typeface which represents a typical value 23 Calculated from formula rise time 0 35 typical bandwidth 22 www tektronix com S parameter Performance Characteristics 80E10 Measurement Conditions All measurements were performed after proper warm up as specified in the DSA8200 manual Standard S parameter dynamic range measurement practices were used to determine the dynamic range of the module Uncertainty results were derived from a wide range of devices with 250 averages Better dynamic range can be achieved by selecting lower bandwidth settings on the 80E10 module due to lower RMS noise floor Results apply to single ended or differential measurements Dynamic Range 80E10 Return Loss S11 Dynamic Range 0 10 20 30 40 50 Frequency GHz 80E10 Insertion Loss S21 Dynamic Range Frequency GHz Digital Serial Analyzer Sampling Oscilloscope DSA8200 Uncertainty Phase degrees 2 amp 8 Bo 80E10 Return Loss S11 Magnitude Uncertainty
51. s around 5 to 6 Gb s and from 9 953 Gb s to 12 5 Gb s ranges The module accepts either single ended or differential signals as its input providing clock recovery for both The signal s is are then passed on to the output connectors at about 50 of the input level and can be connected to sampling module s for differential or single ended sampling Option 10G is required for support of standard rates from 9 953 Gb s to 12 6 Gb s The 80A05 and 80A07 can also serve as the Clock Recovery module for the 80C12 Optical Sampling module 80A06 PatternSync Module The 80A06 PatternSync Trigger module when used in combination with 80SJNB software enables characterizing jitter noise and BER performance of high speed serial designs from 1 Gb s to 60 Gb s data rates It extends the capability of the DSA8200 sampling oscilloscope by creating a pattern trigger from any data related clock a recovered clock user supplied clock sub clock or super clock The PatternSync Trigger module is programmable to pattern lengths of up to 223 bits and accepts a user supplied clock signal from 150 MHz to 12 5 GHz The 80A06 module is required with the DSA8200 when using 80SJNB Advanced Jitter Noise and BER Analysis software package This module can be used in combination with the 82A04 Phase Reference module for the best time base accuracy or for acquisition of signals under SSC Spread Spectrum Clocking Digital Serial Analyzer Sampling Oscilloscope DS
52. t 2 mV 0 007 Offset 0 02 Vertical Value Offset 1 or less over the zone 10 ns to 20 ps before step transition 6 10 or less for the first 400 ps following step transition 0 4 or less over the zone 400 ps to 3 ns following step transition 1 2 or less over the zone 3 ns to 100 ns following step transition 1 after 100 ns following step transition 5 or less for first 300 ps following step transition 30 GHz 300 uV lt 410 pV 20 GHz 280 uV lt 380 uV 1 8 mV 2 4 mV maximum 80E04 10 mV to 1 0 V full scale 2 mV 0 007 Offset 0 02 Vertical Value Offset 3 or less over the zone 10 ns to 20 ps before step transition 10 5 or less for the first 300 ps following step transition 3 or less over the zone 300 ps to 5 ns following step transition 1 or less over the zone 5ns to 100 ns following step transition 0 5 after 100 ns following step transition 600 uV 1 2 mV maximum 80E03 80E01 10 mV to 1 0 V full scale 10 mV to 1 0 V full scale 2 mV 0 007 Offset 0 02 Vertical Value Offset 2 mV 0 007 Offset 0 02 Vertical Value Offset 3 or less over the zone 10 ns to 20 ps before step transition 10 5 or less for the first 300 ps following step transition 3 or less over the zone 300 ps to 5 ns following step transition 1 or less over the zone 5 ns to 100 ns following step transition 0 5 after 100 ns f
53. t um 62 5 62 5 62 5 62 5 Mask Test 16 15 15 15 7 8 9 9 9 9 9 8 Sensitivity dBm Number 1 1 1 1 1 1 1 1 1 1 1 1 of Channels Rates Supported m Filter Optical Clock Recovery Electrical Clock Recovery 9 95 Gb s L on 10 31 Gb s 10 52 Gb s m 10 66 Gb s m E E E 10 71 Gb s 11 1 Gb s 11 3 Gb s 25 78 Gb s 4 6 27 74 Gb s 4 6 39 81 Gb s L 4 4 41 25 Gb s L 4 4 43 02 Gb s L 4 4 4 Contact Tektronix for details 5 Option CRTP reduces sensitivity by 0 6 dB max and increases noise by 15 max 6 Clock recovery with CR286A HS sold separately ele lel o EE SE SE SE pE j el el ejo 6 6 4 4 www tektronix com 7 Data Sheet Optical Modules 80C12 Module 80012 Opt F1 F2 F3 F4 F5 F6 FC 10G CR 7 CR 8 Bandwidth 4 25 9 9 4 25 9 9 9 10 GHz Wavelength 700 1650 700 1650 700 1650 700 1650 700 1650 700 1650 700 1650 700 1650 Range nm Fibre Input 9 or 50 or 62 5 9or500r62 5 9 or 50 or 62 5 9or500r62 5 9 or 50 or 62 5 9 or 50 or 62 5 9 or 50 or 62 5 9 or 50 or 62 5 um Mask Test 19 19 19 19 19 19 19 14 Sensitivity dBm Number of 1 1 1 1 1 1 1 1 Channels Rates Supported m Filter Optical Clock Recovery Electrical Clock Recovery 155 Mb s 622 Mb s 1063 Mb s H L 1250 Mb s 2125 Mb s I m H 7 m 2488 Mb s 2500 Mb s 3
54. t for non sinusoidal phase reference clock signal with frequency between 4 GHz and 6 GHz Order 020 2567 xx 82A04 Filter 6 GHz Filter kit for non sinusoidal phase reference clock signal with frequency between 6 GHz and 8 GHz Order 020 2568 xx 2X Attenuator SMA male to female DC to 18 GHz Order 015 1001 xx 5X Attenuator SMA male to female DC to 18 GHz Order 015 1002 xx Connector Adapter 2 4 mm or 1 85 mm male to 2 92 mm female DC to 40 GHz Order 011 0157 xx Power Divider 50 Q impedance matching power divider SMA male to two SMA females Order 015 0705 xx Rackmount Kit Order 016 1791 xx Wrist Strap Anti static Order 006 3415 04 P7513 P7516 13 GHz and 16 GHz TriMode Differential probes Requires 80A03 Interface module P7260 6 GHz Active FET Probe Requires 80A03 Interface module P7350 5 GHz Active FET Probe Requires 80A03 Interface module P7350SMA 5 GHz 50 Q Differential to Single ended Active Probe Requires 80A03 Interface module Note that the P7380 probes are recommended over the P7350 probes for sampling purposes due to their higher bandwidth and signal fidelity P7380SMA 8 GHz 50 Differential to Single ended Active Probe Requires 80A03 Interface module P6150 9 GHz Passive Probe the probe consists of a very high quality 20 GHz probe tips plus an extremely flexible SMA cable For higher frequency performance the 015 0560 xx or some of the
55. tivity by 0 6 dB max and increases noise by 15 max Optical Sampling Module Characteristics Cont Module Offset Capability Power Meter Power Meter Range Power Meter Accuracy Mask Test Optical Sensitivity 19 80C07B Standard Standard 4 dBm to 30 dBm 5 of reading 22 dBm at 155 Mb s 622 Mb s 20 dBm at 2488 2500 Mb s 80C08C Standard Standard 0 dBm to 30 dBm 5 of reading 16 dBm at all filter rates 80C10B 5 Standard Standard 13 dBm to 21 dBm 5 of reading 25 8 and 27 7 Gb s 80C25GBE 8 dBm 1550 nm and 7 dBm 1310 nm 39 813 to 43 018 Gb s 7 dBm 1550 nm and 6B 1310 mM 80C11 Standard Standard 4 dBm to 30 dBm 5 of reading 10 dBm at all filter rates 7 dBm at 20 GHz 4 dBm at 30 GHz 80012 Standard Standard 0 dBm to 30 dBm 5 of reading 19 dBm for all options except Option 10G 14 dBm for Option 10G 5 Option CRTP reduces sensitivity by 0 6 dB max and increases noise by 15 max 19 Smallest power level for mask test Values represent theoretical typical sensitivity of NRZ eyes for comparison purposes Assumes instrument peak peak noise consumes most of the mask margin www tektronix com 19 Data Sheet Optical Sampling Module Characteristics Cont TDR System 80E10 80E08 80E04 only Module Extinction Ratio Calibrated Accuracy Opt Characteristic 80E10 80E08 80E04
56. ts a typical value 80C08C 80C12 Bandwidths and optical filters valid for OMA lt 500 pW 1550 1310 nm OMA lt 860 uW 850 nm OMA 1020 uW 780 nm Note Refer to Optical Sampling module s User Manual for more detailed information www tektronix com 17 Data Sheet Optical Sampling Module Characteristics Cont Module Clock Recovery Clock Recovery Outputs Unfiltered Optical Absolute Maximum Internal Fibre Diameter Optional Bandwidth 16 Nondestructive Optical Input 80C07B Option CR1 155 Mb s Clock Data 2 5 GHz 5 mW average 10 mW 62 5 125 um 622 Mb s 1 063 Gb s peak power at wavelength of Multi Mode 1 250 Gb s 2 125 Gb s highest responsivity 2 488 Gb s 2 500 Gb s 2 666 Gb s 80C08C 8 Option CR1 9 953 Gb s Clock Clock 16 10 GHz 1 mW average 10 mW 62 5 125 ym 10 31 Gb s peak power at wavelength of Multi Mode Option CR2 10 31 Gb s highest responsivity 10 52 Gb s Option CR4 Continuous from 9 8 Gb s to 12 6 Gb s 80C10B Provided by CR286A HS or ELECTRICAL SIGNAL OUT 80 GHz 20 mW average 60 mW 9 125 um other compatible external to 44 5 Gb s 50 Q AC peak power at wavelength of Single Mode CR units 4 coupled differential 2 92 mm highest relative responsivity female connectors max 1 ps diff skew 17 80C11 Option CR1 9 953 Gb s CR1 Clock Clock 16 Data 28 GHz 5 mW average 10 mW 9 125 um Option CR2 9 953 Gb s CR2 CR3 CR4 Clock peak power at wavelength of Single Mode 10 664 Gb s Cl
57. uW at 155 Mb s 622 Mb s Standard gt 24 dB Single 1063 Mb s 1250 Mb s 1063 Mb s 1250 Mb s Mode 0 70 pW at 2 488 2 500 Gb s 1 5 uW at 2 488 2 500 Gb s 80C08C gt 14 dB Multi Mode Single or Multi Mode 1 7 uW at all filter rates 1550 1310 nm 3 0 uW at all filter rates 1550 1310 nm Standard gt 24 dB Single no CR Mode 80C10B 5 gt 30 dB Single Mode 1310 nm 1550 nm 1310 nm 1550 nm Standard 21 uW 25 8 15 uW 25 8 38 uW 25 8 28 uW 25 8 27 7 Gb s 27 7 Gb s 27 7 Gb s 27 7 Gb s 26 uW 30 GHz 19 uW 30 GHz 45 uW 30 GHz 35 uW 30 GHz 28 uW 39 8 Gb s 20 pW 39 8 Gb s 50 uW 39 8 Gb s 38 uW 39 8 Gb s 43 0 Gb s 43 0 Gb s 43 0 Gb s 43 0 Gb s 44 uW 65 GHz 33 uW 65 GHz 75 uW 65 GHz 60 uW 65 GHz 72 uW 80 GHz 55 uW 80 GHz 130 uW 80 GHz 105 uW 80 GHz 80C11 gt 30 dB Single Mode 5 5 uW at all filter rates 8 0 uW at all filter rates Standard 10 0 uW at 20 GHz 14 0 uW at 20 GHz 20 0 uW at 30 GHz 30 0 uW at 30 GHz 80012 gt 14 dB Multi Mode Single or Multi Mode 1 3 uW all filters except Option 10G 2 5 uW all filters except Option 10G Standard gt 24 dB Single 2 4 uW Full BW and Option 10G filters 5 0 uW Full BW and Option 10G filters Mode 80C25GBE gt 30 dB Single Mode 1310 nm 1550 nm 1310 nm 1550 nm Standard 21 uW 25 8 15 uW 25 8 38 uW 25 8 28 uW 25 8 27 7 Gb s 27 7 Gb s 27 7 Gb s 27 7 Gb s 44 uW 65 GHz 33 uW 65 GHz 75 uW 65 GHz 60 uW 65 GHz 5 Option CRTP reduces sensi
58. ues of modern Serial Data Links equalization with either FFE or DFE channel emulation support for fixture de embedding as well as full support for SSC Spread Spectrum Clocking When you combine jitter noise and BER analysis with the DSA8200 modular flexibility uncompromised performance and unmatched signal fidelity you get the ideal solution for next generation high speed serial data design validation and compliance testing 80SJNB requires the 80A06 PatternSync module which creates a trigger pulse on each complete pattern 80SJNB may be used with the 82A04 Phase Reference module for enhanced accuracy or for SSC signals or without it depending on your requirements SSC max amplitude 5000 ppm 6000 ppm at 30 3 kHz Current version V2 1 of 80SJNB supports save and recall of the complete signal description Also added is anew measurement DDPWS Data Dependent Pulse Width Shrinkage and a corresponding graph 12 www ektronix com 80SJNB Jitter and Noise Analysis Measurements Jitter Analysis Measurements Description TJ at BER Total jitter at specified BER J2 Total jitter for BER 2 5e 3 J9 Total jitter for BER 2 5e 10 RJ Random jitter RJ h Horizontal component of random jitter RJ v Vertical component of random jitter RJ d d Random jitter according to the Dual Dirac model DJ Deterministic jitter DDJ Data dependent jitter DDPWS Data dependent Pulse Width Shrinkage DCD
59. w jitter floor that ensures the most accurate acquisition of high speed signals You get advanced analysis benefits from the 200 fs acquisition jitter with the Phase Reference module And in another step forward for a sampling oscilloscope with the help of the Phase Reference module the DSA8200 can acquire and measure SSC Spread Spectrum Clocking signals The multiprocessor architecture with dedicated per slot digital signal processors DSPs provides fast waveform acquisition rates reducing the test times necessary for reliable characterization and compliance verification The DSA8200 s versatile modular architecture supports a large and growing family of plug ins enabling you to configure your measurement system with a wide variety of electrical optical and accessory modules that best suit your application now and in the future With 6 module slots the DSA8200 can simultaneously accommodate a Clock Recovery module a precision Phase Reference module and multiple acquisition modules electrical or optical so you can match system performance to your evolving needs Featuring industry leading signal fidelity the family of electrical modules includes bandwidth performance from 12 GHz to 70 GHz Two true differential Time Domain Reflectometer TDR modules with remote 2 www tektronix com samplers offer up to 50 GHz bandwidth and 15 ps reflected rise time and 12 ps incident rise time The family of low noise variable bandwidth el
Download Pdf Manuals
Related Search
Related Contents
OWNERS / OPERATORS MANUAL - Carter Ear Force Delta Rig Rat III Detector PDFファイル - 製品評価技術基盤機構 Philips DVDR3380 DVD Player/Recorder 取扱説明書 - M Autostainer Plus User Guide Copyright © All rights reserved.
Failed to retrieve file