1. We recommend that you e Unpack the equipment carefully and save the original box and packaging materials for possible future shipment e Review the contents of this user manual e Use Kramer high performance high resolution cables Go to http www kramerelectronics com to check for up to date user manuals a complete list of Kramer wall plates and module connectors application programs and to check if firmware upgrades are available where appropriate 2 1 Achieving the Best Performance To achieve the best performance e Use only good quality connection cables to avoid interference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quality cables e Avoid interference from neighboring electrical appliances that may adversely influence signal quality e Position your Kramer TBUS 3xl away from moisture excessive sunlight and dust 2 2 Glossary Inner frame The inner frame fits into the TBUS enclosure Universal socket The Universal socket fits almost all power cords worldwide Insert The insert is fitted in the inner frame Go to our Web site to check for a variety of single and dual sized inserts 3 Overview The Kramer TBUS 3xl is a high quality anodized aluminum table mounted connection bus enclosure for boardrooms and conference rooms Its attractive enclosure is designed to provide maximum connectivity in the smallest possible
2. Kramer Electronics for more details 4 2 TBUS 3xl Accessories Accessories Description Inserts You can install any wall plate devices as well as any of the single or dual inserts see our Web site for details T 2INSERT P N 80 00006699 The T 2INSERT kit can be installed inside a single power socket opening and includes 1 single cable pass through insert 1 dual cable pass through insert TBUS 3xl Your TBUS 3xI Enclosure 4 3 Power Socket Options A choice of power sockets per inner frame are available in several versions including power sockets for the USA Germany the Europlug Belgium France Italy South Africa Israel and Australia A Universal socket for general use is also available see the compatibility restrictions in the table below Power Socket Type Universal Power Socket Type USA Power Specs TS 1U 80 000899 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Power Specs TS 1US 80 000999 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Power Socket Type Fully compatible with power plugs in the UK India Italy and Denmark as well as with the 2 prong Europlug Partially compatible if the polarity is reversed with plugs in China Switzerland Israel and the USA The universal socket does not supply grounding to plugs in Central Europe and France and so you should order country specific sockets instead Not compatible with South African pl
3. or owners of this product What Kramer Electronics will do Kramer Electronics will at its sole option provide one of the following three remedies to whatever extent it shall deem necessary to satisfy a proper claim under this limited warranty 1 Elect to repair or facilitate the repair of any defective parts within a reasonable period of time free of any charge for the necessary parts and labor to complete the repair and restore this product to its proper operating condition Kramer Electronics will also pay the shipping costs necessary to return this product once the repair is complete 2 Replace this product with a direct replacement or with a similar product deemed by Kramer Electronics to perform substantially the same function as the original product 3 Issue a refund of the original purchase price less depreciation to be determined based on the age of the product at the time remedy is sought under this limited warranty What Kramer Electronics will not do Under This Limited Warranty If this product is returned to Kramer Electronics or the authorized dealer from which it was purchased or any other party authorized to repair Kramer Electronics products this product must be insured during shipment with the insurance and shipping charges prepaid by you If this product is returned uninsured you assume all risks of loss or damage during shipment Kramer Electronics will not be responsible for any costs related to the removal or re installat
4. surface when mounting the unit and ensure soft tightening to the table underside one for each clamp Locking Butterfly Tighten to lock the mounting butterfly screw one for each Screws clamp Mounting Butterfly Tighten to secure the unit to the table surface one for each Screws clamp Mounting Brackets Fitin the bracket slits after inserting the enclosure into the 2 units table to secure the unit to the table surface one for each clamp Height Adjustment The screw holes on each side panel are used for adjusting the Screw holes height of the inner frame Bracket Slits For attaching the two mounting brackets on opposite sides 10 Tie Holes Insert the self locking tie through the holes to fix the pass through cables to the inside walls of the unit Table Clamping Set 3US 3xl1 Your TBUS 3xl Enclosure 4 1 TBUS 3xl Optional Inner Frames The following inner frames can be installed in the TBUS 3xl enclosure Inner Frames for TBUS 3xl Specifications define what you can include in this inner frame T3F 1S P N 80 002999 1 opening for 1 power socket 1 USB connector 1 VGA 15 pin HD connector 1 RJ 45 Ethernet connector A 3 5mm mini jack AUDIO connector T3F 13 P N 80 003099 1 opening for 1 power socket 2 blank inserts 1 cable pass through insert T3F 1C P N 80 003199 1 opening for 1 power socket 4 cable pass through insert Custom made inner frames can be designed if required Contact
5. KRAMER ELECTRONICS LTD USER MANUAL MODEL MODULAR TBUS B3xI Table Connection Bus P N 2900 300062 Rev 2 TBUS 3xI Quick Start Guide This page guides you through a basic installation and first time use of your TBUS 3xl For more detailed information see the TBUS 3xl user manual and modular instruction sheets You can download the latest manual at http www kramerelectronics com Step 1 Check what s in the box A TBUS 3xl Table Connection Bus Endos re 1 Cut out Template K 2 table clamps K 1 Auick start guide 6 self locking ties 1 User Manual Step 2 Prepare the TBUS 3xl for mounting Step 3 Prepare the table for mounting Cut out an opening in the table using the cut out template Step 4 Install the TBUS 3xl to the table Contents 1 Introduction 2 Getting Started 2 1 Achieving the Best Performance 2 2 Glossary 3 Overview 4 Your TBUS 3xl Enclosure 4 1 TBUS 3xI Optional Inner Frames 4 2 TBUS 3xl Accessories 4 3 Power Socket Options 4 4 Power Cord Options 5 Installing the TBUS 3xl 5 1 Assembling the Inner Frame 5 2 Installing the Inner Frame 5 3 Cutting an Opening in the Table 5 4 Inserting the TBUS 3xl through the Cut Out Opening 5 5 Connecting the Cables 5 6 Inserting Cables via the 4 cable Pass through Insert 5 7 Inserting the Pass through Cables 5 8 Adjusting the Height of the Inner frame 6 Using the TBUS 3xl 7 Technical Specifications of the Assembled TBUS 3
6. SCLAIMER OF IMPLIED WARRANTIES SHALL NOT APPLY TO YOU AND ALL IMPLIED WARRANTIES ON THIS PRODUCT INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR THE PARTICULAR PURPOSE SHALL APPLY AS PROVIDED UNDER APPLICABLE LAW Other Conditions This limited warranty gives you specific legal rights and you may have other rights which vary from country to country or state to state This limited warranty is void if i the label bearing the serial number of this product has been removed or defaced ii the product is not distributed by Kramer Electronics or iii this product is not purchased from an authorized Kramer Electronics reseller If you are unsure whether a reseller is an authorized Kramer Electronics reseller please visit our Web site at www kramerelectronics com or contact a Kramer Electronics office from the list at the end of this document Your rights under this limited warranty are not diminished if you do not complete and return the product registration form or complete and submit the online product registration form Kramer Electronics thanks you for purchasing a Kramer Electronics product We hope it will give you years of satisfaction For the latest information on our products and a list of Kramer distributors visit our Web site where updates to this user manual may be found We welcome your questions comments and feedback Web site www kramerelectronics com KRAMER E mail info kramerel com SAFETY WARNING Disconnect th
7. TED WARRANTY SHALL NOT EXCEED THE ACTUAL PURCHASE PRICE PAID FOR THE PRODUCT TO THE MAXIMUM EXTENT PERMITTED BY LAW KRAMER ELECTRONICS IS NOT RESPONSIBLE FOR DIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY OR CONDITION OR UNDER ANY OTHER LEGAL THEORY Some countries districts or states do not allow the exclusion or limitation of relief special incidental consequential or indirect damages or the limitation of liability to specified amounts so the above limitations or exclusions may not apply to you Exclusive Remedy TO THE MAXIMUM EXTENT PERMITTED BY LAW THIS LIMITED WARRANTY AND THE REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES REMEDIES AND CONDITIONS WHETHER ORAL OR WRITTEN EXPRESS OR IMPLIED TO THE MAXIMUM EXTENT PERMITTED BY LAW KRAMER ELECTRONICS SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IF KRAMER ELECTRONICS CANNOT LAWFULLY DISCLAIM OR EXCLUDE IMPLIED WARRANTIES UNDER APPLICABLE LAW THEN ALL IMPLIED WARRANTIES COVERING THIS PRODUCT INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SHALL APPLY TO THIS PRODUCT AS PROVIDED UNDER APPICABLE LAW IF ANY PRODUCT TO WHICH THIS LIMITED WARRANTY APPLIES IS A CONSUMER PRODUCT UNDER THE MAGNUSON MOSS WARRANTY ACT 15 U S C A 2301 ET SEQ OR OTHER APPICABLE LAW THE FOREGOING DI
8. e unit from the power m supply before opening and servicing
9. footprint The unit is sturdy cost effective and easy to install The TBUS 3xl features e A modular design letting you tailor the TBUS 3xI according to your requirements e A black anodized or brushed clear aluminum lid with a special opening for cable pass through note that other customized colors can also be ordered e Height adjustment screw holes to set the inner frame ordered separately to the desired height e Power socket openings that are suitable for any of the following power sockets for the USA Germany the Europlug Belgium France Italy Australia Israel South Africa or Universal for use anywhere see compatibility restrictions in Section 7 Order the power sockets separately from Kramer Electronics TBUS 3xI is height adjustable and the cover opens and closes manually keeping the cables and the connectors out of sight when not used Figure 1 TBUS 3xI inside a Table Do not place heavy objects on top of the TBUS 3xl TBUS 3xl Overview EA 4 Your TBUS 3xl Enclosure Figure 2 TBUS 3xI Enclosure Top View Feature Function 1 Black Anodized Brushed Includes an opening for cable pass through covers the inner Clear Textured Lid frame leaving the table surface neat and tidy 2 Outer Rim Fits over the table surface A protective rubber guard protects the outer rim during shipping Remove it before installing the unit Inserted into the table cut out Rubber Protectors Protect the table
10. he opening and secure to the table see Section 5 4 5 Connect the cables see Section 5 5 6 Insert the cables via the 4 cable pass through insert see Section 5 6 7 Insert the cables via a pass through insert see Section 5 7 8 Adjust the height of the inner frame see Section 5 8 5 1 Assembling the Inner Frame The modules mounted on the inner frame can include single inserts and or dual inserts as well as a power socket in some models This section describes how to assemble these modules Each module kit comes with detailed assembly instructions TBUS 3xl Installing the TBUS 3x 5 1 1 Mounting the Inserts You can rearrange or remove any of the plates mounted on the inner frame and replace them with Kramer passive wall plates or connector modules for interfacing A V type signals To mount a Kramer insert or connector module 1 Unscrew the two screws that fasten the blank plate to the inner frame and remove the blank plate 2 Place the required Kramer insert over the opening insert the two screws to fix the Kramer insert in place and tighten them Figure 3 TBUS 3x1 Inner Frame P N 80 003099 Feature Function Son Plates aa blank covers that can be replaced with wall aaa E as reguired 2 Adjustable Height Screw Holes For For adjusting the height of the Inner frame the height of the Inner frame 5 1 2 Mounting the Power Socket Assemblies To mount the power socket place the power socke
11. ight of the Inner frame If needed you can adjust the inner frame height to accommodate large or bulky cables To adjust perform the following 1 Remove the height adjustment screws while supporting the surface from underneath with your fingers 2 Raise or lower the inner frame to the required height insert the screws and tighten them in place EH TBUS 3x1 Installing the TBUS 3xl 6 Using the TBUS 3xI Once the TBUS 3xI is installed you can easily customize it to suit your own requirements by plugging in the required A V equipment as illustrated in the example in Figure 7 Video Conference Displ TBUS 3xI isp ay MEA Kramer Switcher Scaler Ethernet Ethernet Sy Power Amplifier Laptop Projector with Speakers Computer Graphics Source Figure 7 TBUS 3xl Boardroom Installation TBUS 3x1 Using the TBUS 3xI EE 7 Technical Specifications of the Assembled TBUS 3xI POWER SOURCE Power Socket Assemblies AC power limits Universal 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Fully compatible with power plugs in the UK India Italy and Denmark as well as with the 2 prong Europlug Partially compatible if the polarity is reversed with plugs in China Switzerland Israel and the USA The universal socket does not supply grounding to plugs in Central Europe and France you should order country specific sockets instead Not compatible with South African p
12. ion of this product from or into any installation Kramer Electronics will not be responsible for any costs related to any setting up this product any adjustment of user controls or any programming required for a specific installation of this product Howto Obtain a Remedy under this Limited Warranty To obtain a remedy under this limited warranty you must contact either the authorized Kramer Electronics reseller from whom you purchased this product or the Kramer Electronics office nearest you For a list of authorized Kramer Electronics resellers and or Kramer Electronics authorized service providers please visit our web site at www kramerelectronics com or contact the Kramer Electronics office nearest you In order to pursue any remedy under this limited warranty you must possess an original dated receipt as proof of purchase from an authorized Kramer Electronics reseller If this product is returned under this limited warranty a return authorization number obtained from Kramer Electronics will be required You may also be directed to an authorized reseller or a person authorized by Kramer Electronics to repair the product If itis decided that this product should be returned directly to Kramer Electronics this product should be properly packed preferably in the original carton for shipping Cartons not bearing a return authorization number will be refused Limitation on Liability THE MAXIMUM LIABILITY OF KRAMER ELECTRONICS UNDER THIS LIMI
13. lugs USA 100 240V AC 50 60Hz 5A a ec Germany and EU 100 240V AC 50 60Hz 5A S manna Belgium and France 100 240V AC 50 60Hz 5A 0 hen ae cel Italy 100 240V AC 50 60Hz 5A inn tert Australia 100 240V AC 50 60Hz 5A fe inn ak gett Maximum 5A per power outlet South Africa 220V AC 50 60Hz 5A pe einen 5A per poner tat TEA 250V OPERATING TEMPERATURE 5 to 45 Deg Centigrade RANGE OPERATING HUMIDITY 10 to 90 RHL non condensing RANGE STORAGE TEMPERATURE 20 to 70Deg C RANGE STORAGE HUMIDITY RANGE 5 to 95 RHL non condensing DIMENSIONS Top plate 176mm x 140 4mm 6 9 x 5 5 W D Enclosure 136mm x 102mm x 130mm 5 4 x 4 0 x 5 1 W D H WEIGHT TBUS 3 0 8kg 1 76lbs approx Table clamps 0 26kg 0 57Ibs Template 0 12kg 0 27Ibs ACCESSORIES Power cord six self locking ties template template screws OPTIONS Inner frames passive wall plates and interfaces power socket kits power cord Specifications are subject to change without notice at http www kramerelectronics com JE TBUS 3xl Technical Specifications of the Assembled TBUS 3xl LIMITED WARRANTY The warranty obligations of Kramer Electronics for this product are limited to the terms set forth below What is Covered This limited warranty covers defects in materials and workmanship in this product What is Not Covered This limited warranty does not cover any damage deterioration or malfunction resulting from any altera
14. t under the frame in its appropriate place and tighten with the two screws supplied Power socket kits come with assembly instructions TBUS 3xl Installing the TBUS 3xl 5 2 Installing the Inner Frame To install the inner frame 1 Place the inner frame inside the TBUS 3xl enclosure 2 Set the required height using your fingers to bring the inner frame to the desired position screw and tighten it in place using the height adjustment screws supplied with the inner frame Inner frame kits come with assembly instructions 5 3 Cutting an Opening in the Table To cut an opening in the table 1 Place the included cut out template that is included with your TBUS 3xl on the surface of the table exactly where you want to install the TBUS 3xl 2 Attach the template to the table with the included screws if using the cut out template 3 Following the inside edge of the template cut a hole in the table surface with a sabre or keyhole saw according to the dimensions shown in Figure 4 not to scale The thickness of the table should be 76 2mm 3 inches or less 158 2mm Figure 4 Cut out Dimensions 10 5 3x1 Installing the TBUS 3xl 4 Unscrew and remove the template from the surface of the table and clean the table surface Take care not to damage the table If needed you can download a full scale template from our Web site Kramer Electronics is not responsible for any damage caused to
15. the table 5 4 Inserting the TBUS 3xl through the Cut Out Opening To install TBUS 3xI in the opening 1 Remove the protective rubber guard from around the outer rim of the TBUS 3xl housing Beware of the sharp edge 2 Carefully insert the unit into the prepared opening see Figure 5 3 Take the support brackets under the table and place them into the support bracket grooves on both sides of the unit see Figure 2 item 7 4 Verify proper alignment of the unit before tightening the mounting screws 5 Tighten both mounting butterfly screws upward until they reach the table surface from underneath Tighten firmly see Figure 5 6 Tighten the locking butterfly screws downward until tight against the mounting bracket Figure 5 Inserting TBUS 3xl into the Prepared Opening TBUS 3xI Installing the TBUS 3x 11 5 5 Connecting the Cables When replacing blank inserts with connector inserts for example VGA audio HDMI and so on 1 Insert the cables to their appropriate connectors from underneath 2 Secure the cables to the tie holes on the TBUS 3xtI Do not secure the cables too tightly or too loosely Leave a small amount of slack After the TBUS 3xI is connected to mains power and the proper cables it is ready for use 5 6 Inserting Cables via the 4 cable Pass through Insert To insert the cables via the 4 cable pass through insert for example to pass cables from beneath the table to several lap
16. tion modification improper or unreasonable use or maintenance misuse abuse accident neglect exposure to excess moisture fire improper packing and shipping such claims must be presented to the carrier lightning power surges or other acts of nature This limited warranty does not cover any damage deterioration or malfunction resulting from the installation or removal of this product from any installation any unauthorized tampering with this product any repairs attempted by anyone unauthorized by Kramer Electronics to make such repairs or any other cause which does not relate directly to a defect in materials and or workmanship of this product This limited warranty does not cover cartons equipment enclosures cables or accessories used in conjunction with this product Without limiting any other exclusion herein Kramer Electronics does not warrant that the product covered hereby including without limitation the technology and or integrated circuit s included in the product will not become obsolete or that such items are or will remain compatible with any other product or technology with which the product may be used How Long Does this Coverage Last Seven years as of this printing please check our Web site for the most current and accurate warranty information Whois Covered Only the original purchaser of this product is covered under this limited warranty This limited warranty is not transferable to subsequent purchasers
17. tops do the following 1 Remove the four screws attaching the split pass through bracket 2 Remove the split grommet s The split grommets are not shown in Figure 6 3 Insert the cable s through the rectangular opening 4 Open the split grommet slightly and insert the required cables 5 Place the split bracket around the grommet and position this assembly over the inner frame 6 Place the four screws appropriately and tighten the split bracket together with the grommet and inserted cables to the inner frame 7 Insert the self locking ties through the tie holes to secure the cables to the inside walls of the enclosure 5 7 TBUS 3x Figure 6 4 cable Pass through Insert P N 80 003199 Inserting the Pass through Cables When replacing a blank insert with the pass through insert for example to connect a laptop do the following 1 Remove the two screws attaching the split pass through bracket Remove the split grommet Insert the cable through the rectangular opening Open the split grommet slightly and insert the required cables Place the split bracket around the grommet and position this assembly over the Inner Frame Place the two screws appropriately and tighten the split bracket together with the grommet and inserted cables to the inner frame Insert the self locking ties through the tie holes to secure the cables to the inside walls of the enclosure 5 8 Adjusting the He
18. ugs Power Specs Power Power Specs Socket Type Italy TS 1IT 80 001499 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Germany and EU TS 1DE 80 001299 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Australia TS 1AU 80 001599 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Belgium and France TS 1FR 80 001399 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Israel TS 1IL 80 001799 220V AC 50 60Hz 5A Maximum 5A per power outlet South Africa TS 1ZA 80 001699 100 240V AC 50 60Hz 5A Maximum 5A per power outlet TBUS 3xlI Your TBUS 3xl Enclosure 4 4 Power Cord Options TBUS 3xl You can order any of the following power cords to use with a modular TBUS Power C ype Description P N 6ft 110V North America C AC US 110V 91 000099 6ft 125V Japan C AC JP 125V 91 000699 6ft 220V Europe C AC EU 220V 91 000199 6ft 250V UK C AC UK 250V 91 000299 6ft 250V India C AC IN 250V 91 001099 6ft 250V 10A China C AC CN 250V 91 001199 6ft 250V 10A South Africa C AC ZA 250V 91 001299 Your TBUS 3xI Enclosure 5 Installing the TBUS 3xI To install the TBUS 3xI perform the following steps 1 Assemble the inner frame see Section 5 1 2 Install the inner frame see Section 5 2 3 Cutan opening in the table see Section 5 3 4 Insert the unit through t
19. xl Figures Figure 1 TBUS 3xl inside a Table Figure 2 TBUS 3xl Enclosure Top View Figure 3 TBUS 3x1 Inner Frame P N 80 003099 Figure 4 Cut out Dimensions Figure 5 Inserting TBUS 3xI into the Prepared Opening Figure 6 4 cable Pass through Insert P N 80 003199 Figure 7 TBUS 3xl Boardroom Installation NOOA O NNN Introduction Welcome to Kramer Electronics Since 1981 Kramer Electronics has been providing a world of unique creative and affordable solutions to the vast range of problems that confront the video audio presentation and broadcasting professional on a daily basis In recent years we have redesigned and upgraded most of our line making the best even better Our 1 000 plus different models now appear in 11 groups that are clearly defined by function GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Matrix Switchers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Specialty AV Products GROUP 7 Scan Converters and Scalers GROUP 8 Cables and Connectors GROUP 9 Room Connectivity GROUP 10 Accessories and Rack Adapters and GROUP 11 Sierra Products Thank you for purchasing the Kramer TBUS 3xl enclosure which is ideal for boardrooms conference and training rooms Note that the inner frame power socket assembly power cord and other inserts for the TBUS 3x1 enclosure are purchased separately 2 Getting Started
Download Pdf Manuals
Related Search
Related Contents
GUIDE DE L`UTILISATEUR S C N / R L R -5 3 0 - S C a リニアモータ単軸ロボット Manuel du bras robot Dagu RP6 Application Note Meet The New FLASH Handheld Power Meter Copyright © All rights reserved.
Failed to retrieve file